Iodide in Milk. Electrochemistry Discover the difference

Size: px
Start display at page:

Download "Iodide in Milk. Electrochemistry Discover the difference"

Transcription

1 Application Note Food & Beverage The finest LC-EC Applications for Food & Beverage analysis Iodide Phenols Bisphenol A Catechins Flavonoids Phenols Antioxidants Resveratrol Epicatechin Quercetin Other polyphenols Carbohydrates Monosaccharides Lactose Other oligo- and polysaccharides Vitamins, minerals etc. A, C, D, E, and K Iodide Q10, ubiquinols n FlexCell with exchangeable working electrode n Diamond working electrode n Robust and reproducible analysis Summary In this application note a sensitive and reliable LC-EC method is presented for the analysis of iodide based on DC amperometry using a flow cell with a diamond working electrode. Conductive diamond has several advantages over conventional electrode materials such as a wide potential window in aqueous solutions, excellent chemical inertness and stability. ALEXYS Application Note # 212_004_03 Electrochemistry Discover the difference

2 Introduction Iodine is an essential trace element for humans. It is a component of the thyroid hormone thyroxin, which regulates the body s metabolic state and the growth and development in children. Iodine deficiency is an important health problem throughout much of the world. The dietary uptake of sufficient trace amounts of iodide is therefore necessary for mental and physical development. Important sources of iodide are seafood, diary products, iodized table salt and processed foods like iodized bread [1]. Table 1 LC-EC Conditions HPLC ALEXYS Iodide Analyzer (part no E) Flow rate 0.4 ml/min Flow cell FlexCell with MD WE and HyREF Temperature 35 C for separation and detection Range 2 μa/v ADF 0.5 Hz I-cell na HPLC in combination with electrochemical detection is commonly used for the analysis of iodide in urine [2,3] and food products [4,5]. 2 na Iodide Figure 1: ALEXYS Iodide Analyzer Time [min.] Figure 2: Chromatogram of a 400 nm of potassium iodide (KI) in water (50.8 μg/l Iodide).Injection volume 20 μl. Method The ALEXYS Iodide analyzer is equipped with a DECADE Elite electrochemical detector and FlexCell with replaceable diamond electrode disc. The LC conditions used with the ALEXYS Iodide Analyzer were selected with the focus on the analysis of iodide in dairy products. Therefore, the same mobile phase and similar separation conditions were used as described in literature [4,5]. 2

3 Results A hydrodynamic voltammogram was recorded in the potential range between 900 and 2400 mv (vs. HyREF) to determine the optimum detection potential, using a 10 μm KI solution in water. Although the onset of the limiting current was observed at 2000 mv, a lower potential of 1500 mv was chosen for detection. At this potential a low background current (<30 na) and noise level are attained in combination with a good detection sensitivity for Iodide. In Figure 2 an example chromatogram is shown of 50.8 μg/l potassium iodide in water (injection volume 20 μl). The peak efficiency for the iodide peak was theoretical plates/meter. Linearity and detection limits Calibration curves were recorded with Iodide standards in the concentration range between 6 μg/l 1.3 mg/l. Within this concentration range a linear detector response was observed with correlation coefficients better than Iodide Area ( μa.s) Iodide concentration (mg/l) 5 na Figure 4: Calibration plot for Iodide in water. Concentration range 6 μg/l 1.3 mg/l. R = Iodide Time [min.] Figure 3: Chromatogram of Iodide in low-fat (1.5%) milk sample. Injection volume 20 μl. 3

4 A concentration detection limit (clod) of approximately 0.4 μg/l (3 nm) was found, demonstrating the excellent detection sensitivity achieved with the MD electrode. The clod is based on an injection volume of 20 μl and defined as the concentration that gives a signal that is three times the peakto-peak noise. Repeatability The repeatability of the method was evaluated by executing 10 repetitive injections (20 μl injection volume) of a 0.13 mg/l and 1.23 mg/l iodide solution. The relative standard deviation (RSD%) for retention time, peak area and height are listed in Table 2 for both concentrations. The relative standard deviation for both peak height and peak area are 1% or better at a concentration of 0.13 mg/l and % at 1.26 mg/l. The long-term repeatability was assessed with a standard with a high iodide concentration of 13.7 mg/l. 225 repetitive injections were performed in a time period of 22 hours, see Figure 5. For this experiment the flow rate was increased with a factor 2 (0.8 ml/min, system backpressure approximately 180 bar) to reduce the analysis time (6 minutes). After the 20 th injection a gap of 6 injections is visible due to an empty vial. 50 Table 2 Repeatability (n=10) Iodide (mg/l) tr Area Height Iodide Area ( A.s) Number of injections Figure 5: Long-term repeatability of DC amperometric detection of iodide on an MD electrode. Sample concentration 13.7 mg/l, injection volume 20 μl. The relative standard deviations (RSD%) for the peak area was 1.4%. It demonstrates the good response stability of MD, even at high iodide concentration. It has been observed that online electrochemical regeneration/ activation is an effective method to restore the detection sensitivity in case the response of the Magic Diamond electrode attenuated over time, or the electrode has not been used for a while. The flow cell does not have to be disassembled in this case. During the online regeneration procedure the detector was operated in the SCAN mode. Typically, the electrode was scanned between 3 Volts and + 3 Volts in mobile phase, with a scan rate of 50 mv/s.. 4

5 Iodide in milk products In Figure 3 an example chromatogram of a low-fat (1.5%) milk sample is shown. The following sample preparation procedure was performed prior to injection n 1 ml 3% acetic acid was mixed with 5 ml of sample for deproteination of the milk solution. The acidified solution was centrifuged and the supernatant collected. n Subsequently, the supernatant was passed over a RP SPE column (Alltech C18-fast column) for further clean-up of the milk matrix (removal of fat). n The eluate (first 2 ml discarded) was collected and 20 ul injected in the LC system. It should be stated that the sample preparation procedure described above is not validated and is only used to obtain a series of example chromatograms. The iodide peak in the chromatogram was identified by spiking a second milk sample prior to sample work-up with a known amount of Iodide, corresponding to a concentration of 317 μg/l. It is evident from Figure 3 that the iodide peak is well separated from the matrix. The concentration of iodide in the milk sample was estimated to be 45 μg/l. Conclusion The ALEXYS Iodide Analyzer provides a user-friendly and reliable solution for the determination of iodide by means of DC amperometry. With the new inert Magic Diamond electrode, iodide can be detected with excellent reproducibility and sensitivity. 5

6 References 1. John T. Dunn, Editorial: What s happening to our Iodine?, J Clin Endocrinol Metab., 83(10), 1998, K.Han, W. Koch, K.W. Pratt, Improved procedure for the determination of Iodide by Ion Chromatography with Electrochemical detection, Anal. Chem., 59, 1987, J. Rendl, S. Seybold, W. Borner, Urinary Iodide determined by Paired-Ion Reversed Phase HPLC with Electrochemical de-tection, Clin. Chem., 40/6, 1994, Determination of iodide content in milk and dried milk by HPLC, International IDF standard, 167: Milk and dried milk Determination of iodide contents method using HPLC, International ISO standard, 14378: W.R. LaCourse, Pulsed Electrochemical Detection in High Performance Liquid Chromatography, John Wiley & Sons, New York, 1 ed, Alexander Kraft, Doped diamond: A compact review on a new, versatile electrode material, Int. J. Electrochem. Sci., 2, 2007, Ordering information E ALEXYS Iodide Analyzer ALE-315 column, 150x3.0mm, 3um C18 Antec Scientific (USA) info@antecscientific.com T Antec Scientific (worldwide) info@antecscientific.com T For research purpose only. The information shown in this communication is solely to demonstrate the applicability of the ALEXYS system. The actual performance may be affected by factors beyond Antec s control. Specifications mentioned in this application note are subject to change without further notice. 6

Bisphenol A in Drinking Water

Bisphenol A in Drinking Water Application Note Food & Beverage The finest LC-EC Applications for Food & Beverage analysis Bisphenol A Phenols Bisphenol A Catechins Flavonoids Phenols Antioxidants Resveratrol Epicatechin Quercetin Other

More information

Mono- and Disaccharides

Mono- and Disaccharides Application Note Food/Beverage/Life Sciences The finest LC-EC Applications for Food & Beverage analysis Mono- and Phenols Bisphenol A Catechins Flavonoids Phenols Antioxidants Resveratrol Epicatechin Quercetin

More information

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products High-Performance Anion-Exchange Chromatography coupled with Pulsed Electrochemical Detection as a powerful tool to evaluate lactose content in lactose-free labeled products Application Note Authors: C.

More information

Carbohydrates in Food

Carbohydrates in Food Application Note Food & Beverage The finest LC-EC Applications for Food & Beverage analysis Carbohydrates Phenols Bisphenol A Catechins Flavonoids Phenols Antioxidants Resveratrol Epicatechin Quercetin

More information

Serotonin in Plasma. Electrochemistry Discover the difference. Summary. Application Note Clinical & Diagnostics

Serotonin in Plasma. Electrochemistry Discover the difference. Summary. Application Note Clinical & Diagnostics Application Note Clinical & Diagnostics The most selective LC-EC applications for Clinical & Diagnostics analysis Serotonin Catecholamines Serotonin Metanephrines VMA HVA 5-HIAA PET imaging tracer Fluorodeoxyglucose

More information

Serotonin in Urine. Electrochemistry Discover the difference

Serotonin in Urine. Electrochemistry Discover the difference Application Note Clinical & Diagnostics The most selective LC-EC applications for Clinical & Diagnostics analysis Catecholamines Serotonin Metanephrines VMA HVA 5-HIAA PET imaging tracer Fluorodeoxyglucose

More information

HVA, VMA and 5-HIAA in Urine

HVA, VMA and 5-HIAA in Urine Application Note ALEXYS - Clinical & Diagnostics The soundest LC-EC Applications for Clinical & Diagnostics Analysis ever Catecholamines Serotonin Metanephrines Homocysteine Glutathione (di-)sulfides Iodide

More information

Aminothiols and Disulfides

Aminothiols and Disulfides Application Note Neuroscience/Clinical ALEXYS Analyzer for Highest Sensitivity in Neurotransmitter Analysis Monoamines and Metabolites Noradrenaline Dopamine Serotonin 5-hydroxyindole acetic acid (5-HIAA)

More information

Metanephrines. in Urine. Clinical & Diagnostics Analysis. Introduction. Application Note ALEXYS - Clinical & Diagnostics

Metanephrines. in Urine. Clinical & Diagnostics Analysis. Introduction. Application Note ALEXYS - Clinical & Diagnostics Application Note ALEXYS - Clinical & Diagnostics The soundest LC-EC Applications for Clinical & Diagnostics Analysis ever Catecholamines Serotonin nephrines VMA HVA 5-HIAA Homocysteine Glutathione (di-)sulfides

More information

Determination of Bisphenol A in Milk Powder using a Chromolith HighResolution RP-18 endcapped column

Determination of Bisphenol A in Milk Powder using a Chromolith HighResolution RP-18 endcapped column Determination of Bisphenol A in Milk Powder using a Chromolith HighResolution RP-18 endcapped column Adelijiang Xiamuxiding and Patrik Appelblad EMD Millipore Introduction Bisphenol A (BPA), figure 1,

More information

ANTEC LEYDEN. Analysis of Carbohydrates in Food and Beverages using Anion-Exchange Chromatography and Pulsed Amperometric. Introduction.

ANTEC LEYDEN. Analysis of Carbohydrates in Food and Beverages using Anion-Exchange Chromatography and Pulsed Amperometric. Introduction. X Axis Title 220_002 #03 ANTEC LEYDEN System solutions from Antec Leyden... naturally! Analysis of Carbohydrates in Food and Beverages using Anion-Exchange Chromatography and Pulsed Amperometric Detection

More information

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode Deteration of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode Bruce Bailey, Marc Plante, David Thomas, Qi Zhang and Ian Acworth Thermo Fisher

More information

Analysis of Lactose and isomers in Lactose-free labelled products

Analysis of Lactose and isomers in Lactose-free labelled products Application Note Food, Beverage, Life Sciences The finest LC-EC Applications for Food & Beverage analysis Phenols Bisphenol A Catechins Flavonoids Phenols Antioxidants Resveratrol Epicatechin Quercetin

More information

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages APPLICATION NOTE 21671 Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages Authors Jon Bardsley, Thermo Fisher Scientific, Runcorn, UK Keywords Vanquish Flex, Acclaim PolarAdvantage

More information

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column APPLICATION NOTE 21673 Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column Authors Aaron Lamb and Brian King, Thermo Fisher Scientific, Runcorn, UK

More information

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice Application Note Author Food Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India 8 6 4 2

More information

Sugar analysis according to the EU Regulation using amperometric detection and Metrosep Carb 2-150/4.0

Sugar analysis according to the EU Regulation using amperometric detection and Metrosep Carb 2-150/4.0 Sugar analysis according to the EU Regulation using amperometric detection and Metrosep Carb 2-150/4.0 Branch Food and beverages Bottle head 6.1602.200 Adsorber tube for Dosing Unit 6.1619.000 Keywords

More information

Iodine HPLC Assay. Catalog Number: IOD34-H Tests For Research Use Only. Not for use in diagnostic procedures.

Iodine HPLC Assay. Catalog Number: IOD34-H Tests For Research Use Only. Not for use in diagnostic procedures. Package Insert Iodine HPLC Assay 100 Tests For Research Use Only. Not for use in diagnostic procedures. v. 1.0 Eagle Biosciences, Inc. 20A Northwest Blvd., Suite 112, Nashua, NH 03063 Phone: 866-419-2019

More information

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution Application Note Food Testing Author Edgar Naegele

More information

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection Bruce Bailey, Marc Plante, David Thomas, Qi Zhang and Ian Acworth Thermo Fisher Scientific, Chelmsford,

More information

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector Mark Benvenuti, Gareth Cleland, and Jennifer Burgess Waters Corporation, Milford, MA, USA

More information

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ Anthony Sullivan, LC/MS Product Specialist Melanie Mülek and Christoph Müller LC-MS Applications Specialists Hewlett-Packard-Str.

More information

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection Mark E. Benvenuti Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Using UPLC with RI detection enables

More information

Articaine & Epinephrine Injection According to USP Method

Articaine & Epinephrine Injection According to USP Method Application Note Drugs & Pharmaceuticals The most reliable LC-EC applications for Drugs & Pharmaceuticals analysis Antipsychotic drugs Clozapine Olanzapine Risperidone PET imaging tracer Fluorodeoxyglucose

More information

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F

More information

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Application Note Food Safety Authors Chenhao Zhai Agilent

More information

Oxidative Metabolism of Amodiaquine using the ROXY EC System

Oxidative Metabolism of Amodiaquine using the ROXY EC System Application Note Drug Metabolism Electrochemical Reactions upfront MS EC/MS Proteomics & Protein Chemistry S-S bond reduction HDX Peptide bond cleavage Na+, K+ removal Drug-protein binding Lipidomics &

More information

Application Note. Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD. Summary.

Application Note. Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD. Summary. Application Note Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD Category Food analysis Matrix Extracts from various food products Method HPAEC-PAD Keywords

More information

APPLICATION NOTE Determination of Aflatoxin M1 via FREESTYLE ThermELUTE with Online HPLC-Measurement

APPLICATION NOTE Determination of Aflatoxin M1 via FREESTYLE ThermELUTE with Online HPLC-Measurement Determination of Aflatoxin M1 via FREESTYLE ThermELUTE with Online HPLC-Measurement APPLICATION NOTE www.lctech.de As of: February 2017, Version: 1.3 Determination of Aflatoxin M1 via FREESTYLE ThermELUTE

More information

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 19 Infinity LC system Application Note Food Authors Standard solution Gerd Vanhoenacker, Frank David, Pat Sandra Research

More information

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610 VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610 BIOCHEMISTRY Vitamins A and E are two fat-soluble vitamins indispensable to animals life for a correct growth and development. Vitamin A exists in three

More information

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection Application Note 9 The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection INTRODUCTION The accurate measurement of the amount of sugar in final molasses

More information

Authors. Abstract. Introduction. Environmental

Authors. Abstract. Introduction. Environmental Determination of Ultratrace Amitrol in Water Samples by in situ Derivatization-Solid Phase Extraction-Liquid Chromatography-Mass Selective Detector Application Environmental Authors Gerd Vanhoenacker,

More information

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with Boron-Doped Diamond Electrode

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with Boron-Doped Diamond Electrode Deteration of Clinically Relevant Compounds using HPLC and Electrochemical Detection with Boron-Doped Diamond Electrode Bruce Bailey, Marc Plante, David Thomas, Qi Zhang and Ian Acworth Thermo Fisher Scientific,

More information

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS Food Application Author Fadwa Al-Taher Institute for Food Safety and Health Illinois Institute of Technology

More information

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases Clinical, Forensic & Toxicology Applications Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases By Shun-Hsin

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of Amantadine Residues in Chicken by LCMS-8040 Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole

More information

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride Received on 15/05/2012; Revised on 22/05/2012; Accepted on 09/06/2012 A Validated Chiral Liquid Chromatographic thod for The Enantiomeric Separation of Dapoxetine Hydrochloride T.Rohith 1 and S. Ananda

More information

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC Application Note Manufacturing QA/QC Authors Syed S. Lateef, Siji Joseph Agilent Technologies Bangalore, India 500 400 Pravastatin

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method

More information

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note

More information

Analysis of HMF by HPLC

Analysis of HMF by HPLC COST Action 927 Training School Building Skills on the Analysis of Thermal Process Contaminants in Foods 22-26 October 2007, Ankara Analysis of HMF by HPLC Vural Gökmen O O OH Background O COOH O R 2 Carbonyl

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Determination of Carbohydrates in Kombucha Using HPAE-PAD Determination of Carbohydrates in Kombucha Using HPAE-PAD Beibei Huang, Jingli Hu, and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA USA Application Note 1152 Key Words Glucose, Fructose, Sucrose,

More information

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application

More information

Application Note. Author. Abstract. Introduction. Food Safety

Application Note. Author. Abstract. Introduction. Food Safety Determination of β2-agonists in Pork with SPE eanup and LC-MS/MS Detection Using Agilent BondElut PCX Solid-Phase Extraction Cartridges, Agilent Poroshell 120 column and Liquid Chromatography-Tandem Mass

More information

Journal of Chemical and Pharmaceutical Research

Journal of Chemical and Pharmaceutical Research Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(1):138-144 Simultaneous RP HPLC determination of Latanoprost

More information

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract JJC Jordan Journal of Chemistry Vol. 4 No.4, 2009, pp. 357-365 Development and Validation of Analytical Method for Fluconazole and Fluconazole Related Compounds (A, B, and C) in Capsule Formulations by

More information

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms Asian Journal of Chemistry Vol. 22, No. 7 (2010), 5067-5071 RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms A. LAKSHMANA RAO*, G. TARAKA RAMESH and J.V.L.N.S. RAO Department of Pharmaceutical

More information

Betadex Sulfobutyl Ether Sodium According to USP

Betadex Sulfobutyl Ether Sodium According to USP Application Note Drugs & Pharmaceuticals The most reliable LC-EC applications for Drugs & Pharmaceuticals analysis Antipsychotic drugs Clozapine Olanzapine Risperidone PET imaging tracer Fluorodeoxyglucose

More information

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2016, 8 (11):236-242 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4

More information

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography Application ote Food Safety Authors Chen-Hao Zhai and Yun Zou Agilent Technologies Co. Ltd.

More information

Pelagia Research Library

Pelagia Research Library Available online at www.pelagiaresearchlibrary.com Der Pharmacia Sinica, 2015, 6(1):6-10 ISSN: 0976-8688 CODEN (USA): PSHIBD Validated RP-HPLC method for simultaneous estimation of metformin hydrochloride

More information

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610 AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610 INTRODUCTION Amiodarone is an antiarrhythmic agent used for various types of tachyarrhythmias, both ventricular and supraventricular arrhythmias.

More information

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Application Note General Chromatography, Food Industry Authors John W. Henderson Jr., Judy Berry, Anne Mack, William Long Agilent

More information

HPLC Analysis of Sugars

HPLC Analysis of Sugars HPLC Analysis of Sugars Pre-Lab Exercise: 1) Read about HPLC, sugars and the experiment and its background. 2) Prepare a flowchart as appropriate for the lab exercise. 3) Note the various sugar concentrations

More information

Analysis of short chain organic acids in tobacco and in some flavored e-liquids

Analysis of short chain organic acids in tobacco and in some flavored e-liquids Analysis of short chain organic acids in tobacco and in some flavored e-liquids S.C. Moldoveanu, Karen B. Kilby, Amanda G. Hudson 1 Background Short chain organic acids from acetic to caprylic play an

More information

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No. Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are

More information

Impurity Profiling of Carbamazepine by HPLC/UV

Impurity Profiling of Carbamazepine by HPLC/UV Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis

More information

Application Note. Authors. Abstract. Food

Application Note. Authors. Abstract. Food Determination of Hormones in Shrimp by Agilent 129 Infinity LC with Agilent Poroshell 12 LC Column and Agilent Bond Elut QuEChERS for Sample Preparation Application Note Food Authors Rongjie Fu and Andy

More information

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants Selectivity Comparison of Agilent Poroshell 1 Phases in the Separation of Butter Antioxidants Application Note Food Testing & Agriculture Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd. Abstract

More information

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology Application Note Small Molecule Pharmaceuticals and Generics Authors Ritu Arora, William udson, Ben Yong, and Paul Boguszewski

More information

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA Fast Determination of Lactose and Lactulose in Dairy Products Using a 4 μm Particle Column and High-Performance Anion-Exchange Chromatography with Carl Fisher, Terri Christison, Hua Yang, Monika Verma,

More information

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application

More information

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS Int. J. Chem. Sci.: 6(4), 2008, 2055-2061 DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS B. S. SASTRY a, S. GANANADHAMU and G. DEVALA RAO K. V.

More information

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system A practical guide on how to use parameters to increase peak capacity Application Note Pharmaceutical and Chemical Author

More information

Analysis of bisphenol A leaching from baby feeding bottles

Analysis of bisphenol A leaching from baby feeding bottles Agilent Application Solution Analysis of bisphenol A leaching from baby feeding bottles Application Note Consumer Products Author Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India Abstract

More information

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page: Research Article CODEN: AJPAD7 ISSN: 2321-0923 Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page: www.ajpamc.com ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF GEFITINIB

More information

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical

More information

Determination of Sucralose Using HPAE-PAD

Determination of Sucralose Using HPAE-PAD Application Note 59 Determination of Sucralose Using HPAE-PAD INTRODUCTION Sucralose is used in the manufacture of nonnutritive sweetened food and beverage products. Sucralose, like most carbohydrates,

More information

Unequalled durability against water elution. % tr

Unequalled durability against water elution. % tr Unequalled durability against water elution 2 Revolutionary aqueous durability for aminopropyl phase 1 3 4 1. fructose (2.5mg/mL) 3. sucrose (2.5mg/mL) 500 hr 2. glucose 400 hr Aqueous to non-aqueous Normal

More information

Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC

Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC Chapter III Optimization of extraction method and profiling of plant phenolic compounds through RP-HPLC 1. INTRODUCTION Phenolics compounds are naturally present antioxidants, found in a variety of plant

More information

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography Application Note 65 Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography INTRODUCTION Preservatives are commonly added to many food products, such as soda, fruit juice,

More information

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS A RAPID AD SESITIVE AALYSIS METD OF SUDA RED I, II, III & IV I TOMATO SAUCE USIG ULTRA PERFORMACE LC MS/MS Choon Keow G, aomi TAAKA, Michelle KIM, Swee Lee YAP Waters Asia, Regional Technology Center,

More information

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2013, 5(1):180-184 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 A simple and sensitive RP-HPLC method for estimation

More information

Scholars Research Library

Scholars Research Library Available online at www.derpharmachemica.com Scholars Research Library Der Pharma Chemica, 2010, 2(5): 46-52 (http://derpharmachemica.com/archive.html) ISSN 0975-413X CODEN (USA): PCHHAX Development and

More information

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE WORLD JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES Ramalakshmi et al. SJIF Impact Factor 6.647 Volume 7, Issue 2, 1010-1018 Research Article ISSN 2278 4357 METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC

More information

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method ISSN: 0973-4945; CODEN ECJHAO E- Chemistry http://www.e-journals.net 2011, 8(3), 1212-1217 Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage

More information

Analytical Method Development and Validation for the Estimation of Guaifenesin and Dextromethorphan by RP-HPLC

Analytical Method Development and Validation for the Estimation of Guaifenesin and Dextromethorphan by RP-HPLC Human Journals Research Article September 2018 Vol.:13, Issue:2 All rights are reserved by Ramya Sree Borra et al. Analytical Method Development and Validation for the Estimation of Guaifenesin and Dextromethorphan

More information

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD) LIFE SCIENCES AR ENOUGH? HOW DO YOU KNOW RAW MATERIALS ARE PURE? HOW DO YOU EVALUATE PRODUCT PACKAGING? HOW DO YOU DO YOU KNOW WHAT ANALYTICAL TECHNIQUE TO USE? HOW DO YOU SIMULTANEOUSLY TEST FOR TWO BYPRODUCTS?

More information

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer application Note Liquid Chromatography/ Mass Spectrometry Authors Sharanya Reddy Blas Cerda PerkinElmer, Inc. Shelton, CT USA Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate

More information

Betadex Sulfobutyl Ether Sodium according to USP

Betadex Sulfobutyl Ether Sodium according to USP Application Note ALEXYS - pharma ALEXYS Analyzer for Highest Sensitivity in Neurotransmitter Analysis Monoamines and Metabolites Noradrenaline Dopamine Serotonin 5-hydroxyindole acetic acid (5-HIAA) 3,4-dihydroxyphenylacetic

More information

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling Application Note Food 1 Agilent 12 Infinity 1 Author Siji Joseph Agilent Technologies, Inc. Bangalore,

More information

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610 AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z6 INTRODUCTION Amiodarone is an antiarrhythmic agent used for various types of tachyarrhythmias, both ventricular and supraventricular arrhythmias.

More information

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids PO-CON1576E Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids HPLC 2015 PSB-MULTI-06 Yoshiyuki WATABE, Tetsuo IIDA, Daisuke NAKAYAMA, Kanya TSUJII, Saki

More information

Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN

Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN Jon W. Wong U.S. Food and Drug Administration Center for Food Safety and Applied Nutrition American Council of Independent Laboratories

More information

The LC Column Playbook

The LC Column Playbook The LC Column Playbook Mark Powell Applications Engineer Technical Support 1 Overview How do we achieve our goal: Resolution? Efficiency Particle size Column length Selectivity Bonded phase Mobile phase

More information

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector application Note UHPLC Author Njies Pedjie PerkinElmer, Inc. Shelton, CT 06484 USA Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector Introduction Foods

More information

Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin

Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin LOGO Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin Rapid Quantification of Tilidine, Nortilidine and Bisnortilidine in Urine

More information

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

ISSN: ; CODEN ECJHAO E-Journal of Chemistry  2011, 8(3), ISSN: 0973-4945; CODEN ECJHAO E- Chemistry http://www.e-journals.net 2011, 8(3), 1275-1279 Simultaneous Determination of Paracetamol, Phenylephrine Hydrochloride, Oxolamine Citrate and Chlorpheniramine

More information

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS Tanya Jenkins Waters Corporation, Milford, MA, USA INTRODUCTION Some of the most challenging methods

More information

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40 International Research Journal of Pharmaceutical and Applied Sciences Available online at www.irjpas.com Int. Res J Pharm. App Sci., 2012; 2(4):35-40 Research Article Estimation of Fesoterodine fumarate

More information

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page: ISSN: 2320-2831 Research article Open Access Method development and validation of tenofovir disoproxil fumerate and emtricitabine in combined tablet

More information

Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA200

Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA200 Application Update 15 Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA2 INTRODUCTION High-performance anion-exchange chromatography with pulsed amperometric detection

More information

Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction

Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction Application Note FB0113 Keywords SPE (Solid Phase Extraction), Bovine Milk, JECFA (Joint FAO/WHO Expert

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

A HPAE-PAD Chromatographic Assay for Carbohydrates in Urine as a Measure of Intestinal Permeability

A HPAE-PAD Chromatographic Assay for Carbohydrates in Urine as a Measure of Intestinal Permeability A HPAE-PAD Chromatographic Assay for Carbohydrates in Urine as a Measure of Intestinal Permeability Deanna Hurum and Jeffrey Rohrer, Thermo Fisher Scientific, Sunnyvale, CA, USA Overview Purpose: A high-performance

More information