Publishable Summary for 15HLT06 MRTDosimetry Metrology for clinical implementation of dosimetry in molecular radiotherapy

Similar documents
Publishable JRP Summary Report for JRP HLT11 MetroMRT Metrology for Molecular Radiotherapy Background

Application of 3D Printing to Molecular Radiotherapy Phantoms. Nick Calvert Nuclear Medicine Group The Christie NHS Foundation Trust, Manchester

Strategic Research Agenda of EURAMED, highlighting synergies

3D Printed Phantoms for MRT Dosimetry

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

The IAEA BSS and development of an international dosimetry protocol

Quantitative Imaging: A hospital physicist s perspective James Scuffham

EURADOS Work on Internal Dosimetry

Calculation methods in Hermes Medical Solutions dosimetry software

METROLOGY TO SUPPORT INNOVATION IN MOLECULAR RADIOTHERAPY. Glenn Flux

The IAEA and Non-Communicable Diseases The Fight Against Non-Communicable Diseases

EURADOS: Overview of actions and initiatives in radiation protection in medicine

7. Radioisotopes in Medicine

The OpenGATE Collaboration

Highlights from TC-IR

The Management of Imaging Procedure Dose Nuclear Medicine Dose Indices

Radionuclides in Medical Imaging. Danielle Wilson

Guideline & Reports 医学物理学会教育委員会資料

Verification of Advanced Radiotherapy Techniques

Sterilization of health care products Radiation. Part 3: Guidance on dosimetric aspects of development, validation and routine control

ICRP: What It Does and Why Dr Jack Valentin

Catharine Clark NPL, Royal Surrey County Hospital and RTTQA

Strategic Research Agenda of EURADOS, highlighting synergies

nuclear science and technology

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

Quantitative Theranostics in Nuclear Medicine

COMMISSION STAFF WORKING DOCUMENT IMPACT ASSESSMENT. Accompanying the document COUNCIL DIRECTIVE

Overview of ICRP Committee 3 Protection in Medicine

Journal of Radiation Research and Applied Sciences 8 (2015) 317e322. Available online at ScienceDirect

Erasmus Experience. Lu-DOTA-octreotate PRRT

45 Hr PET Registry Review Course

Facilitating Lu 177 Personalized Dosimetry for Neuroendocrine Tumours CANM 2017

Future upcoming technologies and what audit needs to address

nuclear science and technology

Application of IDEAS Guidelines: the IDEAS/IAEA Intercomparison Exercise on Internal Dose Assessment.

Dosimetry Optimization System and Integrated Software (DOSIS): a comparison against Fluka code results over a standard phantom

ERICA an overview. Brenda Howard, NERC. 1 EC Contract: FI6R-CT

Radiation physics and radiation protection. University of Szeged Department of Nuclear Medicine

REPORT OF THE TECHNICAL MEETING: THE NEW DOSE LIMIT FOR THE LENS OF THE EYE IMPLICATIONS AND IMPLEMENTATION VIENNA, 2-4 OCTOBER 2012

Dose Estimates for Nuclear Medicine Procedures: What are they? Where do they come from?

EBAMP European Board for Accreditation in Medical Physics

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Good Laboratory Practice. EU-Serbia screening meeting Brussels, 19 June 2014

Option D: Medicinal Chemistry

Development and prospects on dosimetry at radiotherapy levels in the Secondary Standard Dosimetry Laboratory of Cuba.

39th Annual UIA Symposium. Metrology research for External Beam Cancer Therapy. K.-V. Jenderka

ISO INTERNATIONAL STANDARD

nuclear science and technology

Volunteering in NHSScotland Developing and Sustaining Volunteering in NHSScotland

Highlights and Conclusions Thematic Area 4: Radiation of Patients

nuclear science and technology

What s s on the Menu in Europe? - overview and challenges in the first pan- European food consumption survey

EU safeguards contribution to the global nuclear non-proliferation regime. Safeguards implementation in the European Union

Project Fiche IPA Horizontal Programme on Nuclear Safety and Radiation Protection

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

Deliverable. Grant Agreement number: Open Access Policy Alignment STrategies for European Union Research. FP7 CAPACITIES Science in Society

Education & Training for Radiation Dosimetry

Quality and Safety Initiatives for Radiation Oncology in Europe: different approaches, united view.

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

A Real-Time Monte Carlo System for Internal Dose Evaluation Using an Anthropomorphic Phantom with Different Shapes of Tumors Inserted

Market surveillance of medical devices

Perspectives on national decision makers: The healthcare policy maker

Approval of Dosimetry Services in Ireland Guidelines for Applicants

Assessing the standard dose to standard patients for x-ray investigations

COMMITTEE OF EXPERTS ON THE CLASSIFICATION OF MEDICINES AS REGARDS THEIR SUPPLY (CD-P-PH/PHO) PROGRAMME RESULTS

2008 Public Status Report on the Implementation of the European Risk Management Strategy. Executive Summary

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 1: General principles

Medical Use of Radioisotopes

8/1/2017. Disclosures. Outline. SAM Imaging Education Course 90Y-Microsphere Therapy: Emerging Trends and Future Directions

A Snapshot on Nuclear Cardiac Imaging

Strengthening Activity Measurement Quality in Radiation Protection from Metrological Science to Reliable End-user Application

International Symposium on Quality Assurance for Analytical Methods in Isotope Hydrology

New Radiation Health Technologies Challenges, Opportunities, Limitations

Atoms for Health. Atoms for Health The. Atoms for Health - Division of Nuclear Health - Dept of Nuclear Aplications P Andreo DIR-NAHU 1

Nuclear Medicine and PET. D. J. McMahon rev cewood

Patients, Staff, Public, Animals Evaluate RP needs related to emerging technologies. Produce recommendations and user-friendly guidance on RP.

Medical Physicists Improving treatments, saving lives

Accreditation of Dosimetry Services

REVISED CODEX GENERAL STANDARD FOR IRRADIATED FOODS CODEX STAN , REV

Isotopes in Functional Cancer Imaging

Calibration of 90 Sr+ 90 Y sources used for betatherapy, using a postal kit of thermoluminescent dosimeters

Postgraduate Diploma in Health Sciences in Medical Imaging (Nuclear Medicine Pathway)

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

EORTC Member Facility Questionnaire

PACT: Together against Cancer. The problem: Cancer in low and middle income countries. Case for Support

Third announcement. Joint FMU-ICRP Workshop on Radiological Protection in Medicine. Tuesday, October 3, 2017

IAEA activities in the field of dosimetry for Radiopharmaceutical Therapy

Radiation Protection Research. From FP6 to FP7. Neale Kelly

Common strategic research agenda for radiation protection in medicine

Sterilization of health care products - Radiation - Part 3: Guidance on dosimetric aspects

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

Molecular Imaging and the Brain

International Practice Accreditation

International Conference on Integrated Medical Imaging in Cardiovascular Diseases (IMIC 2016)

Metrology in pharmaceutical production

RADIATION PROTECTION NO 175

Internal Dosimetry of Human Brain for 99m tc and 131 I Using Nuclear Imaging in Bangladesh

Monte Carlo Modelling: a reliable and efficient tool in radiation dosimetry

Radiation Exposure to Staff Using PET/CT Facility

Transcription:

Publishable Summary for 15HLT06 MRTDosimetry Metrology for clinical implementation of dosimetry in molecular radiotherapy Overview The overall aim of this project is to provide the metrology for the clinical implementation of absorbed dose calculations in Molecular Radiotherapy (MRT). The project builds on the results and outputs from the preceding EMRP JRP HLT11 MetroMRT, which took the first steps towards providing data, methods, protocols and guidance for MRT dosimetry in collaboration with many European MRT clinics as well as radiopharmaceutical companies and camera manufacturers. The focus of this follow-on project is clinical implementation and it is strongly directed by the involvement of leading MRT clinics across Europe as well as building on metrology expertise. Need In the last few years there has been an increase in Europe in the development and use of radiopharmaceuticals for treating cancer as well as an increase in the number of MRT clinical trials that are expected to start in the near future. However, in spite of the growing acceptance that an accurate knowledge of the radiation absorbed dose to critical tissues would provide a more effective targeted use of MRT, most patient treatments still follow the historical practice of administering a nominal activity of the radiopharmaceutical. It is well known that the administered activity is not a good predictor of tissue dose and hence the outcome of patient treatment, due to individual variation in uptake and retention. However, one of the main reasons for a reluctance to perform individual patient dose measurements is that the process is complicated and there are no standard methods for calibrating or implementing MRT dosimetry in clinics. Therefore, the MRT community has an urgent need for dosimetry calibration standards, validation methods, and clear guidance on how to implement MRT dosimetry in every European clinic offering MRT. Without this, it will not be possible to comply with EC Directive 2013/59/EURATOM, Article 56, which states that individual dose planning for radiotherapy patients (including MRT) must be enforced in legislation by EU member states by 6 February 2018. The previous EMRP JRP HLT11 MetroMRT clearly identified the key needs for obtaining dose measurements for MRT patients. These are: (1) measurement of the administered activity, (2) quantitative imaging (QI) of the activity localised in the patient using Single Photon Emission Computed Tomography (SPECT) or Positron Emission Tomography (PET) Computed Tomography (CT), (3) integration of activity measurements over the time of treatment, (4) calculation of the dose from activity measurements and (5) estimation of the overall uncertainty of the measurement. Each of these needs is addressed in the current project s objectives, with the first being in response to the need for more accurate QI measurement of the administered activity, such as the beta-emitters 90 Y and 166 Ho, which are used with microspheres for liver cancer treatment. The current main source of uncertainty in MRT dosimetry is in taking the step from dose measurements on simple reference geometries to QI measurements of the complex and varying geometries of the activity localised in real patients, as well as activity measurements over the time of treatment. All these issues will be addressed by this project using SPECT and PET methods, through the development of 3D printed quasirealistic anthropomorphic phantoms and by creating a database of reference images of geometries covering typical clinical situations. Dosimetry for MRT, as currently performed, has no traceability to primary standards of absorbed dose. Therefore there is an urgent need to achieve traceability and to validate the dose calculation methods. Further to this, and central to any recommendations for dosimetry methods, is knowledge of the overall uncertainty associated with any particular method. Hence, the uncertainties in relation to the full MRT dose measurement chain (i.e. from a primary standard to a dosimetry calculation platform) also need to be determined. Report Status: PU Public Publishable Summary Issued: May 2017 This publication reflects only the author s view and the Commission is not responsible for any use that may be made of the information it contains. 1/5

Objectives The overall aim of this project is to provide the metrology for the clinical implementation of absorbed dose calculations in MRT. In order to do this, the specific objectives of this project are: 1. To determine branching ratios and emission probabilities for 90 Y and 166 Ho in order to enable improved quantitative imaging (QI) accuracy and dose estimation for these radionuclides, and to exploit new technologies in order to develop a suitable transfer instrument optimised for accuracy of measurements of the activity of MRT agents in clinics and radiopharmaceutical companies. 2. To develop 3D printing methods in order to generate a range of quasi-realistic anthropomorphic phantoms containing compartments fillable with known activities of radioactive liquid or standardised sealed radioactive test sources, having a range of geometrical complexity for validation of multimodal QI or absorbed dose measurement, and estimation of the uncertainties of measurement. In addition, to expand the protocol developed in JRP HLT11 for traceable calibration of SPECT QI for 177 Lu activity to include PET-CT QI of 90 Y and SPECT QI of 131 I, validated by measurements using the quasi-realistic anthropomorphic 3D printed phantoms. 3. To generate multimodal images either from SPECT or PET-CT phantom measurements or Monte Carlo (MC) simulations to provide material for an open-access database of reference images to be used as reference data for commissioning and Quality Control (QC) of QI using SPECT or PET-CT. In addition, to develop an architecture for and host the open-access database. 4. To improve the accuracy and metrological traceability in the calculation of dose from time-sequences of QI measurements by optimisation of the time points (i.e. obtaining cumulated activity from a time-activity-curve (TAC)), choice of measurement modality (imaging or non-imaging), refinement of absorbed dose standards, and validation of alternative absorbed dose calculation methods in phantoms using physical measurement techniques such as Magnetic Resonance (MR) sensitive gel-based and film-based dosimetry and MC simulations. 5. To determine uncertainties in relation to the full MRT dose measurement chain from a primary standard to a range of commercial and non-commercial dosimetry calculation platforms. This includes image quantification (such as uncertainties in the selection of volumes of interest (VOI) and image reconstruction); integration of TACs, propagation of uncertainties in NTCP models, and determination of the overall evaluated uncertainty in the absorbed dose quantification process. 6. To facilitate the take up by healthcare professionals (clinical centres) and industry (scanner manufacturers and software developers) of the technology and measurement infrastructure developed by the project. Progress beyond the state of the art The previous JRP HLT11 MetroMRT defined the key needs in MRT dosimetry. Using this information, this project will address these needs on two fronts: firstly, scientific development aimed at reducing the uncertainty of each of the key links in the measurement chain in order to obtain a robust measurement protocol with traceability to primary standards. Secondly, the provision of standardised methods, test objects, open-access databases, and implementation/commissioning guidelines in order to support MRT clinics in setting up and validating dosimetry. In particular: Objective 1 will provide new data to enable more accurate PET imaging of 90 Y (widely used for liver and neuroendocrine tumours) and will design a new transfer instrument to provide greater accuracy in the calibration of activity measurements in clinical departments. Work is currently underway to make the first direct measurement of the probability of 90 Y positron emission by the direct detection of positrons emitted from 90 Y. This novel technique is a powerful alternative to indirect detection of photons from the annihilation of the emission positrons. Monte Carlo (MC) simulations of the new activity transfer instrument have been completed and the designs are now being finalised for production. Objective 2 will use 3D printing to develop a range of quasi-realistic anthropomorphic phantoms that can be filled in various ways with accurately known activities of radionuclides, used to mimic measurements of real patients, in order to validate QI measurements and to estimate the uncertainties associated with different QI methods. In particular the QI calibration protocol developed in JRP HLT11 will be expanded and tested. 2/5

Objective 3 will develop an open-access database of measured or MC-simulated test images of phantoms that are readable by contemporary clinical camera systems and that are accessible to most commercial software packages in order to allow clinics to test their MRT dosimetry methods. These images will each have a correct activity and dose-rate calculated by MC models and also verified by measurements. In addition, protocols will be developed for the commissioning and QC of QI and MRT dosimetry systems. Objective 4 will further develop measurement methods introduced in JRP HLT11 MetroMRT, such as a primary standard of absorbed dose to water from a radionuclide solution; in order to verify the accuracy of the MC methods that are the basis of MRT absorbed dose calculation. Methods for the integration of activity measurements over the time of treatment will be developed as well as, the choice of measurement modality (imaging or non-imaging), refinement of absorbed dose standards, and validation of alternative absorbed dose calculation methods, such as MR sensitive gel-based and film-based dosimetry. Objective 5 will continue the development of uncertainty analysis methods in relation to the full MRT dose measurement chain, and will generate uncertainty estimation methods for different dosimetry techniques and different patient geometries. Results The first nine months of the project have focused on the design of several new technologies which allow the validation of quantitative imaging and subsequent dose calculations based on this imaging. These technologies address the accuracy of clinical activity measurements (a new activity transfer instrument) and provide more realistic and complex test objects (anthropomorphic phantoms and radioactive test sources). Objective 1: To determine branching ratios and emission probabilities for 90Y and 166Ho in order to enable improved quantitative imaging (QI) accuracy and dose estimation for these radionuclides, and to exploit new technologies in order to develop a suitable transfer instrument optimised for accuracy of measurements of the activity of MRT agents in clinics and radiopharmaceutical companies A highlight of this work has been establishing the specifications and a prototype design for a new transfer instrument for high-energy beta-emitters i.e. 90 Y and 166 Ho that will be optimised for accuracy of measurements of the activity of MRT agents in clinics and radiopharmaceutical companies. The designs for this transfer instrument, which will increase the accuracy of measurements of activity in clinics and radiopharmaceutical companies, have now been extensively tested using Monte Carlo simulations, allowing construction of the device to now proceed. Objective 2: To develop 3D printing methods in order to generate a range of quasi-realistic anthropomorphic phantoms containing compartments fillable with known activities of radioactive liquid or standardised sealed radioactive test sources, having a range of geometrical complexity for validation of multimodal QI or absorbed dose measurement, and estimation of the uncertainties of measurement. In addition, to expand the protocol developed in JRP HLT11 for traceable calibration of SPECT QI for 177Lu activity to include PET CT QI of 90Y and SPECT QI of 131I, validated by measurements using the quasi-realistic anthropomorphic 3D printed phantoms. Novel designs have been made for: (1) a series of long-lived radioactive test sources based on 133 Ba which can be used as an analogue for shorted lived medical isotopes to compare the performance of QI across clinical centres, and (2) quasi-realistic anthropomorphic phantoms which provide realistic analogues for the human body. 3/5

Impact The key to the success of this project will be in ensuring that the methods and tools developed are taken up by the European MRT community. The previous JRP HLT11 MetroMRT attracted a network of 33 European collaborating clinics, camera manufacturers, and radiopharmaceutical companies and the stakeholders for this project will be built upon this network to support maximum participation and uptake. The project will also be working with the European Federation of Organisations in Medical Physics (EFOMP), and the International Atomic Energy Agency (IAEA). A Working Group has been set up by the Dosimetry and Medical Radiation Physics section of the Division of Human Health at the IAEA, to produce a publication on MRT dosimetry in the Human Health Series and this Working Group includes 4 of the project partners. The IAEA is considered to be the main international authority on medical radiation dosimetry protocols and has also agreed in principle to host the open-access database of test images produced by the project (objective 3). Members of the consortium are also members of several ISO committees such as (ISO/TC 85 and ISO/TC 69) and are members of the Dosimetry Committee of the EANM (which produces European guidelines for applications of MRT dosimetry) and every opportunity will be taken to exploit the project s results with these committees. Further to this, the project will make a submission to the Committee on Medical Internal Radiation Dose (MIRD) on the methodology of uncertainty analysis for imaging and non-imaging methods for obtaining cumulated activity from a TAC (objective 5). The MIRD has been accepted for many decades as the international standard for radiopharmaceutical dose calculation. There will be many tangible outputs from this project which will be of direct use to the MRT community, including not only MRT clinics, but software, imaging equipment, and radiopharmaceutical manufacturers. The continuation of the development of a primary standard of absorbed dose to water from a radionuclide solution (started in JRP HLT11) will be an essential part of establishing traceability of MRT dosimetry to primary standards. This is the only standard of this type worldwide, and it will be of considerable interest to the ionising radiation metrology community (objective 4). The details of this standard have recently been published in Metrologia, the leading international journal for this research area (doi:10.1088/0026-1394/53/6/1259). A recent publication by project members also addresses the validation of clinical scale absorbed dose calculations in nuclear medicine dosimetry (objective 3, doi:10.1088/1361-6560/62/5/1885). In addition to this, the designs for the 3D printed quasi-realistic anthropomorphic phantoms (objective 2) will also be made available to end-users (via the scientific literature), as will the open-access database of test images, which is intended to be readable by contemporary clinical camera systems and accessible to most commercial software packages, so that it can be used for commissioning dosimetry systems. In addition, it is planned that the new transfer instrument (objective 1) will become commercially available and that this will lead to an improvement in the accuracy of the calibration of activity measurements in clinical departments. Further to this, the new data to enable more accurate PET imaging of 90 Y and new activity standards and measurements of the decay scheme for 166 Ho (objective 1) will be published in peer-reviewed scientific journals. Nuclear data published in this way will be evaluated by the Decay Data Evaluation Project (DDEP) for inclusion in their internationally-recognised database of nuclear data. The ultimate aim of the project is to encourage and assist European MRT clinics, and those worldwide, to adopt dosimetry as a routine part of patient treatment. The project will also support compliance with the EC Directive 2013/59/EURATOM, and bring MRT into line with other radiotherapy modalities. The end result should be more effective, better targeted treatment, for the benefit of patients and the healthcare system. List of publications Billas, I., Shipley, D., Galer, S., Bass, G., Sander, T., Fenwick, A., & Smyth, V. (2016). Development of a primary standard for absorbed dose from unsealed radionuclide solutions. Metrologia, 53(6), 1259 1271. http://doi.org/10.1088/0026-1394/53/6/1259 Villoing, D., Marcatili, S., Garcia, M.-P., & Bardiès, M. (2017). Internal dosimetry with the Monte Carlo code GATE: validation using the ICRP/ICRU female reference computational model. Physics in Medicine and Biology, 62(5), 1885 1904. http://doi.org/10.1088/1361-6560/62/5/1885 4/5

Project start date and duration: June 2016, 36 months Coordinator: Andrew Robinson, NPL Tel: +44 208 943 7174 E-mail: andrew.robinson@npl.co.uk Project website address: http://mrtdosimetry-empir.eu Internal Funded Partners: 1 NPL, Germany 2 BEV-PTP, Austria 3 CEA, France 4 CMI, Czech Republic 5 ENEA, Italy 6 SCK CEN, Belgium External Funded Partners: 7 ASMN, Italy 8 Christie, UK 9 INSERM, France 10 Lund, Sweden 11 THG, Greece 12 UKW, Germany Unfunded Partners: 13 AOSP, Italy 14 BRFAA, Greece 15 CARD, UK 16 OPBG, Italy 17 OUHT, UK 18 RSCH, UK 5/5