TITANIUM TIBIAL NAIL SySTEM

Similar documents
The Titanium Tibial Nail System

Titanium Distal Femoral Nail System

Technique Guide. SureLock Distal Targeting Device. C-arm guided targeting for trochanteric fixation nail.

The Titanium Cannulated Tibial Nail with Proximal Bend. Expert nailing system.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Suprapatellar Instrumentation for Titanium Cannulated Tibial Nail. Expert nailing system.

3.5 mm Locking Attachment Plate

titanium cannulated adolescent lateral entry femoral nail

Titanium Cannulated Adolescent Lateral Entry Femoral Nail. Expert Nailing System.

Titanium Cannulated Lateral Entry Femoral Recon Nail

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Double Engine Orthopedic Bone Nail System Universal Humeral Nail

3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments

Titanium Cannulated Retrograde/ Antegrade Femoral Nail

Titanium Solid Humeral Nail System

Suprapatellar Instrumentation for Expert Tibial Nail.

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Tibial Nail. Expert TN. Surgical Technique

THE UNIVERSAL NAIL SYSTEM

System. Humeral Nail. Surgical Technique

Expert TN. Tibial Nail.

Olecranon Osteotomy Nail. For simple fractures and osteotomies of the olecranon.

Sirus Antegrade Femoral Nail System Surgical Technique

NeoGen Tibia Nail System

Expert A2FN. Designed for small statured patients.

OPERATING MANUAL AND TECHNIQUE GUIDE FOR TITANIUM FEMORAL AND TIBIAL NAILING SYSTEMS

Femoral Recon Nail System FRN

PediNail Pediatric Femoral Nail

3.5 mm LCP Extra-articular Distal Humerus Plate

designed to advance the treatment of hip fractures.

GREENS SURGICALS. Redefining Excellence INSTRUMENT SYSTEM PREPARED BY: DR. VINAY KUMAR

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Low Bend Distal Tibia Plates

For Distal Femur Fractures. 95º Condylar Plate. Quick Reference Chart

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems.

Expert ALFN. Adolescent Lateral Femoral Nail

Expert A2FN. Designed for small statured patients.

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

UTN/CTN Solid/Cannulated Tibial Nail Surgical Technique

The Universal Nail System.

AcUMEDr. FoREARM ROD SYSTEM

3.5 mm LCP Olecranon Plates

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

The CerviFix System. Including the StarLock Components. CerviFix Clamp and Screw. StarLock Clamp and Screw

Large Distractor Femur

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 4.5 mm LCP Proximal Tibia Plates. Part of the Synthes LCP Periarticular Plating System.

Expert ALFN. Adolescent Lateral Femoral Nail.

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

Phoenix Tibial Nail System

Periarticular Aiming Arm Instruments for LCP Proximal Tibial Plate 4.5/5.0. Part of the LCP Periarticular Aiming Arm Instrument System (large).

Cannulated Pediatric Osteotomy System (CAPOS)

Humeral Nails With Multiple Locking Options for Simple and Complex Fractures. MultiLoc. Humeral Nails. Surgical Technique

4.5 mm VA-LCP. Part of the Variable Angle Periarticular Plating System

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

PROXIMAL FEMORAL NAIL REMOVAL SET

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

NeoGen Femoral Nail System

Femoral Recon Nail System FRN

Technique Guide. TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee.

For intramedullary fixation of proximal femoral fractures SURGICAL TECHNIQUE

3.5 mm LCP Tibial Plateau Sets. Configuration options.

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

M/DN Tibial and Humeral Intramedullary Fixation. Surgical Technique

2.7 mm/3.5 mm LCP Distal Fibula Plate

Part of the DePuy Synthes Locking Compression Plate (LCP ) System. 3.5 mm LCP Medial Proximal Tibia Plates

Lag Screw Device Intended for symphyseal fracture fixation of the mandible

Surgical Technique.

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

Surgical Technique. Forearm Fracture Solutions

4.5 mm LCP Medial Proximal Tibia Plates

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

UFN Unreamed Femoral Nail CFN Cannulated Femoral Nail

Surgical Technique. Intramedullary locked Nailing With Screws for Humerus Fractures Solid/Cannulated. Humeral Interlocking Nail.

KL 3255 PediNail_tech_Rev.D_Layout 1 10/8/12 1:18 PM Page 1. PediNail Pediatric Femoral Nail

Large External Fixator Delta Frame Ankle Bridge. For staged fixation of the distal tibia.

UHN/PHN Humeral Nailing System.

6.5 mm midfoot fusion bolt

Zimmer Natural Nail System

Expert R /AFN Retrograde /Antegrade Femoral Nail.

Surgical technique. UHN/PHN Humeral Nailing System.

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

Zimmer ITST Intertrochanteric/ Subtrochanteric Fixation System. Abbreviated Surgical Technique

Compact Distal Radius System. Consolidated solution for Distal Radius Plating Systems

low ProfIle neuro PlaTIng system

Large External Fixator Modular Knee Bridge. Using multi-pin clamps.

Expert R/AFN. Retrograde/Antegrade Femoral Nail.

Surgical Technique. Fibula Rod System

3.5 mm LCP Clavicle Hook Plates

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.

INTRAMEDULLARY. Medical Devices. Femur Intramedullary Nail

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

humerus InSafeLOCK Nail

Technique Guide. Epoca Revision Instrument Set. For extraction and revision of Epoca shoulder implants.

4.5 mm LCP Condylar Plate Aiming Instruments

Transcription:

TITANIUM TIBIAL NAIL SySTEM Solid and Cannulated Nails SURGICAL TEChNIqUE

Table of contents Introduction Indications 2 Preoperative Implant Selection 6 Surgical Technique Instruments for Opening the Tibia 7 Opening the Tibia 8 Reaming Guidelines 11 Instruments for Inserting the Nail 12 Inserting the Nail 13 Instruments for Locking Proximally 15 Locking Proximally 17 Fractures Involving Proximal Third Component 20 Locking Distally 22 Inserting End Cap 24 Implant Removal 25 product information Implant Specifications 26 Titanium Tibial Nail Insertion and Locking Set 28 [105.570] Titanium Tibial Nail Insertion and Locking Set 28 with Locking Screws [105.572] Image intensifier control Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma

Indications Indications for the Titanium Tibial Nail The Titanium Solid Tibial Nail is intended to stabilize fractures of the tibia. Specifically it is intended for Grades I and II open tibial diaphyseal fractures; high energy, unstable closed fracture patterns; comminuted fractures of tibias with small medullary canals; and certain pre- and postisthmic fractures. The Titanium Cannulated Tibial Nail is intended to stabilize fractures of the tibia. Indications include, but are not limited to, open and closed tibial shaft fractures; certain pre- and postisthmic fractures; tibial malunions and tibial nonunions. 2 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Case Examples Proximal and distal locking hole configurations provide a choice of locking options, both static and dynamic, to accommodate the fracture pattern and soft-tissue injury: CASE 1 Diaphyseal fracture Locked dynamically, with proximal and distal locking bolts or locking screws in the frontal plane. Note: Results from case reports are not necessarily predictive of results in other cases. Results in other cases may vary. Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 3

Case Examples CASE 2 Fracture involving the proximal third component Locked statically, the oblique superior locking bolt or locking screw improves control of proximal third fractures. 4 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Case Examples CASE 3 Distal fracture Locked with distal locking bolts or locking screws in both the sagittal and frontal planes. Distal AP interlocking allows placement of perpendicular bolts or screws for more secure fixation of the short distal fragment. Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 5

Preoperative Implant Selection Use the AO Preoperative Planner Ruler to determine nail length and nail diameter. Note: There are two templates available for use: true size and 115% magnification. The template image is magnified 15% to account for average radiograph magnification; however, variations in magnification levels are common. For solid nails, select the Titanium Solid Tibial Nail Ruler. For cannulated nails, select the Titanium Cannulated Tibial Nail Ruler. When selecting nail size, consider canal diameter, fracture pattern, and postoperative protocol. 6 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Instruments for Opening the Tibia Jacob s Chuck with Key 511.73 ComPact Air Drive II 511.701 2.5 mm Threaded Guide Wire 900.723 Double Air Hose 519.51S 11.0 mm Cannulated Drill Bit 360.06 12.0 mm Drill Sleeve 360.17 Medullary Canal Length Gauge (optional) 356.55 Radiographic Ruler, for Tibial Nails 356.59 Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 7

Opening the Tibia Position the patient Position the patient supine on a radiolucent operating table. Ensure that the knee of the injured leg can be flexed at least 90, and x-ray visualization of the entire tibia is possible in both the AP and lateral views. Temporary reduction and stabilization can be accomplished by manual pressure at the fracture site, or by application of a sterile tourniquet or elastic bandage around the fracture. Alternatively, the Large Distractor may be used on the medial side, with the insertion of Schanz screws, in the frontal plane, as close as possible to each tibial end. At the surgeon s discretion, the procedure can be performed on a fracture table with the leg placed in traction. Confirm nail length Position the image intensifier for an AP view of the distal tibia. With a long forceps, hold the ruler alongside the leg, parallel to and at the same level as the tibia. Adjust the ruler until the distal tip is at the level of the physeal scar or the desired nail insertion depth. Mark the skin at the bottom of the ruler. Move the image intensifier to the proximal tibia, replace the distal end of the ruler at the skin mark, and take an AP image of the proximal tibia. Read nail length directly from the ruler image, selecting the measurement at or just below the level of the anterior edge of the tibial plateau. The distal tip of the ruler should align with the physeal scar (or desired nail insertion depth). When using the Large Distractor, measure the distance from the inferior border of the distal pin to the superior border of the proximal pin to determine optimal nail length. AP image of proximal tibia 8 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Opening the Tibia Identify nail entry point The entry point for the nail is in line with the medullary canal in the AP view, and is at the anterior edge of the tibial plateau. The location of the entry point in relation to the tibial tubercle varies with patient anatomy. Make a longitudinal incision over the midline of the tubercle, extending proximally. Retract the patellar tendon laterally, or split the tendon, depending on surgeon preference and patient anatomy. Insert the 2.5 mm Threaded Guide Wire [900.723] through the incision to the entry point. Under an AP image intensification view, center the guide wire in line with the medullary canal. Note: For treatment of fractures involving the proximal third component refer to the section titled Fractures Involving Proximal Third Component (page 20). Entry point AP view Entry point lateral view Insert the centering pin/guide wire AP view Insert the centering pin/guide wire lateral view Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 9

Opening the Tibia Open the canal With a power drill or hand chuck, insert the 2.5 mm guide wire through the metaphysis and into the medullary canal. Direct the wire so it is parallel to the anterior cortex and closely approxi mates the 9 angulation of the proximal nail. To ensure correct wire placement, hold a sterile nail anterior to the tibia and use it as an angle guide. Confirm wire placement with the image intensifier. Place the 11.0 mm Cannulated Drill Bit into a cannulated drill and place the 12.0 mm Drill Sleeve [360.17] over the guide wire. Place the drill bit over the 2.5 mm guide wire and through the drill sleeve. Drill an opening into the medullary canal to a depth of approximately 100 mm. Remove the drill, guide wire and drill sleeve. Open the medullary canal Confirm nail length (optional) Insert the Medullary Canal Length Gauge [356.55] into the tibia. Use the C-arm to verify insertion depth. Read nail length directly from the gauge at the entry site. 11 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Reaming Guidelines (Optional Technique) Under image intensification, reduce the fracture and insert the appropriate reaming rod into the canal to the level of the distal metaphysis. Ream in 0.5 mm increments, and advance the reamer with steady, moderate pressure. Do not force the reamer. Partially retract the reamer often to clear debris from the medullary canal. Ream to a diameter 0.5 mm to 1.0 mm greater than nail diameter. After reaming, remove the reaming assembly. Pass the Medullary Tube [355.006] down the reamed canal, over the reaming rod. Remove the reaming rod and insert the Guide Rod, with smooth tip, through the Medullary Tube. Remove the Medullary Tube, leaving the guide rod in position for insertion of the cannulated nail. Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 11

Instruments for Inserting the Nail Insertion Bolt for Titanium Solid Tibial Nails 356.542 Insertion Bolt for Titanium Cannulated Tibial Nails 356.544 Titanium Tibial Nail Insertion Handle 356.511 Combination Wrench 321.16 Inserter-Extractor for Titanium Tibial and Humeral Nails 356.49 Slotted Hammer 332.20 Cannulated Socket Wrench 355.14 Driving Head 355.18 11 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Inserting the Nail Assemble the insertion instruments Orient the insertion handle anteriorly, and match the flats on the handle and nail. For solid nails, select the Insertion Bolt for Titanium Solid Tibial Nails [356.542]. For cannulated nails, select the Insertion Bolt for Titanium Cannulated Tibial Nails [356.544]. Place the insertion bolt into the insertion handle and thread it into the proximal nail end. Tighten the insertion bolt with the Cannulated Socket Wrench [355.14], but do not overtighten. Inserter-Extractor for Titanium Tibial Nails 356.49 Thread the Inserter-Extractor onto the threaded post of the insertion handle. Note: Do not attach the aiming arm for nail insertion. Titanium Tibial Nail Insertion Handle 356.511 Insertion Bolt for Titanium Solid Tibial Nails 356.542 Solid Tibial Nail Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 11

Inserting the Nail For solid nails, place the nail into the tibial opening with the insertion handle oriented anteriorly. For cannulated nails, place the nail over the guide rod and into the tibial opening with the insertion handle oriented anteriorly. Verify fracture reduction and insert the nail as far as possible by hand. Monitor nail passage across the fracture under image intensification. With the leg in flexion, use light blows of the slotted hammer on the Inserter-Extractor until the top of the nail is at or below the tibial opening. Note: The nail must be fully inserted in flexion. Insertion instrument assembly 11 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Instruments for Locking Proximally For all Tibial Nails Quick Coupling for Drill Bits 511.75 ComPact Air Drive II 511.701 Locking Bolt Measuring Device 357.792 Hose 519.51S Hexagonal Screwdriver 314.75 11.0 mm/ 8.0 mm Protection Sleeve 355.70 8.0 mm Trocar 355.75 Titanium Tibial Nail Insertion Handle 356.511 Titanium Tibial Nail Aiming Arm 356.521 Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 11

Instruments for Locking Proximally For 8 mm and 9 mm diameter Tibial Nails (3.9 mm Locking Bolts) 8.0 mm/3.2 mm Drill Sleeve 355.72 3.2 mm Three-Fluted Calibrated Drill Bit, 215 mm, 80 mm calibration, quick coupling 356.97 For 10 mm 13 mm diameter Tibial Nails (4.9 mm Locking Bolts) 8.0 mm/4.0 mm Drill Sleeve 357.711 4.0 mm Three-Fluted Calibrated Drill Bit, 215 mm, 80 mm calibration, quick coupling 356.982 11 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Locking Proximally Proximal locking can be achieved with the leg in full extension. This neutralizes the deforming forces on proximal fragments caused by the quadriceps mechanism and relieves the pressure on soft tissue usually associated with tibial nail insertion instruments. This position also facilitates assessment of rotational alignment prior to locking. Locking Options Stat 1 for static, transverse locking. Stat 2 for static, transverse locking. Allows locking of very proximal fractures. Dynamic for immediate dynamization. Oblique for the most superior proximal locking option. Oblique Locking Hole Titanium Tibial Nail Aiming Arm 356.521 Dynamic Stat 2 Stat 1 Attach the Aiming Arm For transverse locking, orient the aiming arm for medial to lateral locking bolt or locking screw insertion. For interlocking through the oblique locking hole, attach the aiming arm to the insertion handle for an anterolateral or anteromedial approach. Tighten the spring-loaded connecting knob to secure the aiming arm to the insertion handle. Confirm that the insertion handle is securely fastened to the nail. Tighten the insertion bolt if necessary. Attach the Aiming Arm Proximal locking instrumentation assembly Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 11

Locking Proximally Lock proximally Choose the appropriate insertion hole, as marked on the aiming arm. Insert the 11.0 mm/8.0 mm Protection Sleeve and 8.0 mm Trocar into the aiming arm, and through a stab incision to the bone. To interlock 8 mm and 9 mm nails: Interlock the blue 8 mm and 9 mm nails with the blue 3.9 mm locking bolts or 4.0 mm locking screws. Remove the trocar and insert the 8.0 mm/3.2 mm Drill Sleeve into the protection sleeve. The drill sleeve will snap into place when properly seated in the protection sleeve. Drill both cortices with the 3.2 mm Calibrated Drill Bit, stopping the drill immediately after penetrating the far cortex. To interlock 10 mm, 11 mm, 12 mm, and 13 mm nails: Interlock the 10, 11, 12, and 13 mm green tibial nails with the green 4.9 mm locking bolts or 5.0 mm locking screws. Use the 8.0 mm/4.0 mm Drill Sleeve and drill with the 4.0 mm calibrated drill bit. Drill with 3.2 mm Drill Bit Note: There is no need to calculate locking bolt or locking screw length because the calibrated drill bit provides a direct measurement. However, since drill bit position directly represents locking bolt or locking screw position in bone, the locking bolt or screw will be too long if the drill bit is overinserted, or if the drill sleeve is not pressed down to the cortex. Confirm drill bit position radiographically. Be sure the drill sleeve is pressed firmly to the cortex, and read locking bolt or screw length from the calibrated drill bit at the back of the drill sleeve. 11 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Locking Proximally When using the Locking Bolt Measuring Device, remove the drill sleeve and the outer sleeve of the measuring device. Place the measuring slider and needle through the protection sleeve and measure for locking bolt or screw length. Locking bolt or screw length is read directly from the measuring device at the back of the protection sleeve. Locking Bolt Measuring Device 357.792 Place Measuring Device through Protection Sleeve Insert the locking bolt or screw through the protection sleeve using the screwdriver. Repeat the procedure for a second transverse proximal locking bolt or locking screw. Insert Transverse Locking Bolt or Locking Screw Insert Oblique Locking Bolt or Locking Screw Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 11

Fractures Involving Proximal Third Component Apply Large Distractor The Large Distractor is applied on the medial side. The distractor will help to keep the fracture out to length and aid reduction. To correct overlapping fragments, which are usually posterior, it may be necessary to introduce a Schanz screw into the floating fragment and pull it into reduction. 22 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Fractures Involving Proximal Third Component Identify nail entry point For fractures in the proximal third of the tibia, it is essential to select an entry site for the nail which is as superior as possible and in line with the lateral intercondylar eminence. It is important to align the guide wire with the lateral spine of the tibial plateau. Hyperflexion of the proximal fragment assists placement of the nail as anterior and parallel to the anterior cortex as possible. The sagittal plane entry site is critical. Insert and lock the nail When the nail has been fully inserted as indicated in the Inserting the Nail section on page 13, the leg can be placed in extension. Locking is then performed with the fractured leg in full extension. Proximal locking can be performed as described in the previous sections. Note: The nail must be fully inserted in flexion. Once the nail is fully inserted, extension may be accomplished. Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 22

Locking Distally Use the Radiolucent Drive Align image Align the image intensifier with the most distal hole in the nail until a perfect circle is visible. Round (correct) Oblique (incorrect) Determine incision point Place a knife blade on the skin to determine the incision point, and make a stab incision. Carefully dissect the underlying tissues to reduce the risk of saphenous vein perforation. Determine incision point Center drill bit in locking hole Under image intensification, insert the tip of the radiolucent drive drill bit through the incision and place it onto the bone. Keep the drill bit oblique to the x-ray beam until the tip is centered in the locking hole. Center drill bit in locking hole 22 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Locking Distally Important: Use the 3.2 mm radiolucent drive drill bit [511.414] for 8 mm and 9 mm nails. Use the 4.0 mm radiolucent drive drill bit [511.417] for 10 mm 13 mm nails. Drill Tilt the drive until the drill bit is in line with the beam and appears centered in the outer ring. The drill bit will virtually fill the locking hole image. Hold the drill firmly in this position and drill through both cortices. Measure Measure for the locking bolt or locking screw using the Locking Bolt Measuring Device. Locking bolt or screw length is read directly from the device. Insert locking bolt or locking screw Insert the appropriate size titanium locking bolt or screw using the screwdriver and holding sleeve. Align drill bit Locking Bolt Measuring Device 357.792 For standard freehand technique: Use the standard drill bit to perform freehand distal locking. x Use the 3.2 mm drill bit [356.97] for 8 mm and 9 mm nails. x Use the 4.0 mm drill bit [356.982] for 10 mm 13 mm nails. Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 22

Inserting the End Cap Remove the nail insertion instru ments. Select the appropriate end cap or end cap extension piece. Align the end cap with the proximal nail end, and insert it into the coupling threads with the screwdriver. Turn the end cap until it is fully seated within the nail. Insert end cap 22 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Implant Removal Remove locking bolts or locking screws and end cap Clean tissue ingrowth from the hex of the end cap and locking bolts or locking screws. Use the screwdriver to remove the end caps and locking bolts or locking screws. Note: Before removing the last locking bolt or screw, thread the Extraction Screw into the proximal nail end. This will prevent the nail from rotating in the medullary canal. Inserter-Extractor 356.49 Remove the nail Insert the Extraction Screw for the Titanium Tibial Nail and thread it into the proximal nail end. Tighten the Extraction Screw with the 11 mm Combination Wrench [321.16]. Thread the Inserter-Extractor onto the connecting screw, and remove the nail with reverse blows of the Slotted Hammer. Extraction Screw 356.543 Inserter- Extractor Extraction Screw Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 22

Implant Specifications Titanium Tibial Nails Material: Titanium- 6% aluminum 7% niobium alloy Color-Coded: 8 mm and 9 mm nails are blue for use with blue 3.9 mm locking bolts or 4.0 mm locking screws. 10 mm 13 mm nails are green for use with green 4.9 mm locking bolts or 5.0 mm locking screws. 9 proximal bend Titanium Solid Tibial Nails (blue and green) Size: Diameters: 8, 9 and 10 mm Lengths: 255 360 mm, in 15 mm increments; 380 420 mm, in 20 mm increments Titanium Cannulated Tibial Nails (green) Size: Diameters: 10, 11, 12, and 13 mm Lengths: 255 360 mm, in 15 mm increments; 380 420 mm, in 20 mm increments Solid 8 mm and 9 mm (blue) Solid 10 mm (green) Cannulated 10 mm 13 mm (green) Oblique locking hole close to proximal nail end for stable interlocking of proximal-third fractures Dynamic slot for 1 cm of controlled, axial dynamization Stat 2 transverse locking hole Stat 1 transverse locking hole Three distal locking holes, for locking in both frontal and sagittal planes, allow perpendicular bolt or screw fixation of distal fractures. MR INFORMATION This device has not been evaluated for safety and compatibility in the MR environment. This device has not been tested for heating or migration in the MR environment. 22 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Implant Specifications 4.0 mm Titanium Locking Screw (blue) [458.8xx] 3.3 mm core diameter 5.0 mm Titanium Locking Screw (green) [458.9xx] 4.3 mm core diameter 3.9 mm Titanium Locking Bolt (blue) [458.xx] Lengths: 18 80 mm, in 2 mm increments 3.25 mm core diameter Fully threaded Self-tapping trocar tip 3.5 mm hexagonal drive 4.9 mm Titanium Locking Bolt (green) [459.xx] Lengths: 26 60 mm, in 2 mm increments 64 80 mm, in 4 mm increments 85 100 mm, in 5 mm increments 4.25 mm core diameter Fully threaded Self-tapping trocar tip 3.5 mm hexagonal drive Titanium End Cap, for Titanium Solid Tibial Nails [458.10] 6 mm diameter Protects nail threads from tissue ingrowth Sits flush with proximal nail end Titanium End Cap, for Titanium Cannulated Tibial Nails [458.120] 8 mm diameter Protects nail threads from tissue ingrowth Sits flush with proximal nail end Titanium End Cap 15 mm Extension, for Titanium Solid Tibial Nails [458.110] Extends length of nail by one size Negates reinsertion of a longer nail Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma 22 27

Titanium Tibial Nail Insertion and Locking Set (105.570) Titanium Tibial Nail Insertion and Locking Set, with locking screws (105.572) Instruments 314.11 holding Sleeve, for use with Hexagonal Screwdriver 314.75 Hexagonal Screwdriver 315.31 3.2 mm Three-Fluted Drill Bit, 145 mm, quick coupling, 2 ea. 315.40 4.0 mm Three-Fluted Drill Bit, 195 mm, quick coupling, 2 ea. 319.97 Screw Forceps 321.16 Combination Wrench, 11 mm width across flats 332.20 Slotted Hammer 900.723 2.5 mm Threaded Guide Wire, 230 mm, 4 ea. 355.14 Cannulated Socket Wrench, 11 mm width across flats 355.18 Driving Head 355.70 11.0 mm/8.0 mm Protection Sleeve 355.72 8.0 mm/3.2 mm Drill Sleeve, 104 mm 355.75 8.0 mm Trocar 356.49 Inserter-Extractor, for Titanium Tibial and Humeral Nails 356.511 Titanium Tibial Nail Insertion Handle 356.521 Titanium Tibial Nail Aiming Arm 356.542 Insertion Bolt, for Titanium Solid Tibial Nails, 2 ea. 356.543 Extraction Screw, for Titanium Tibial Nails, 2 ea. 356.544 Insertion Bolt, for Titanium Cannulated Tibial Nails, 2 ea. 356.55 Medullary Canal Length Gauge, 460 mm 356.59 Radiographic Ruler, for Tibial Nails 356.97 3.2 mm Three-Fluted Calibrated Drill Bit, 215 mm, 80 mm calibration, quick coupling, 2 ea. 356.982 4.0 mm Three-Fluted Calibrated Drill Bit, 215 mm, 80 mm calibration, quick coupling, 2 ea. 357.711 8.0 mm/4.0 mm Drill Sleeve, 105 mm 357.792 Locking Bolt Measuring Device, 16 to 80 mm 360.06 11.0 mm Cannulated Drill Bit, 190 mm 360.17 12.0 mm Drill Sleeve Graphic Case, for Titanium Tibial Nail Insertion and Locking Set [304.580] Implants 458.10 Titanium End Cap, for Titanium Solid Tibial Nails, 5 ea. 458.110 Titanium End Cap 15 mm Extension, for Titanium Solid Tibial Nails, 3 ea. 458.120 Titanium End Cap, for Titanium Cannulated Tibial Nails, 5 ea. 458.26.80 3.9 mm Titanium Locking Bolts, 2 mm increments, 2 ea. 459.26.60 4.9 mm Titanium Locking Bolts, 2 mm increments, 2 ea. 459.64.80 4.9 mm Titanium Locking Bolts, 4 mm increments, 2 ea. 458.826.880 4.0 mm Titanium Locking Screws, 2 mm increments, 2 ea. 458.926.960 5.0 mm Titanium Locking Screws, 2 mm increments, 2 ea. 458.964.980 5.0 mm Titanium Locking Screws, 4 mm increments, 2 ea. Included in set 105.570 Included in set 105.572 For detailed cleaning and sterilization instructions, please refer to: www.synthes.com/cleaning-sterilization In Canada, the cleaning and sterilization instructions will be provided with the Loaner shipments. 22 DePuy Synthes Trauma Titanium Tibial Nail System Surgical Technique

Titanium Tibial Nail Insertion and Locking Set (105.570) Titanium Tibial Nail Insertion and Locking Set, with locking screws (105.572) Titanium Solid Tibial Nails (8 mm 10 mm diameters) 8 mm diameter 478.25 255 mm 478.27 270 mm 478.28 285 mm 478.30 300 mm 478.31 315 mm 478.33 330 mm 478.34 345 mm 478.36 360 mm 478.38 380 mm 478.40 400 mm 478.42 420 mm 9 mm diameter 479.25 255 mm 479.27 270 mm 479.28 285 mm 479.30 300 mm 479.31 315 mm 479.33 330 mm 479.34 345 mm 479.36 360 mm 479.38 380 mm 479.40 400 mm 479.42 420 mm 10 mm diameter 476.25 255 mm 476.27 270 mm 476.28 285 mm 476.30 300 mm 476.31 315 mm 476.33 330 mm 476.34 345 mm 476.36 360 mm 476.38 380 mm 476.40 400 mm 476.42 420 mm Titanium Cannulated Tibial Nails (10 mm 13 mm diameters) 10 mm diameter 485.025 255 mm 485.027 270 mm 485.028 285 mm 485.030 300 mm 485.031 315 mm 485.033 330 mm 485.034 345 mm 485.036 360 mm 485.038 380 mm 485.040 400 mm 485.042 420 mm 11 mm diameter 485.125 255 mm 485.127 270 mm 485.128 285 mm 485.130 300 mm 485.131 315 mm 485.133 330 mm 485.134 345 mm 485.136 360 mm 485.138 380 mm 485.140 400 mm 485.142 420 mm 12 mm diameter 485.225 255 mm 485.227 270 mm 485.228 285 mm 485.230 300 mm 485.231 315 mm 485.233 330 mm 485.234 345 mm 485.236 360 mm 485.238 380 mm 485.240 400 mm 485.242 420 mm 13 mm diameter 485.325 255 mm 485.327 270 mm 485.328 285 mm 485.330 300 mm 485.331 315 mm 485.333 330 mm 485.334 345 mm 485.336 360 mm 485.338 380 mm 485.340 400 mm 485.342 420 mm Also Available 150.060 Flexible Reamer Set for IM nails 105.954 Small Battery Drive with 14.4 V Battery Pack Set 351.02 Small Awl, 210 mm 351.06 4.0 mm Centering Pin, 400 mm 351.24 11.0 mm Cannulated Cutter 351.26 Protection Sleeve, for Cannulated Cutter 351.706S 2.5 mm Reaming Rod with ball tip, 950 mm, sterile 351.707S 2.5 mm Reaming Rod with ball tip and extension, 950 mm, sterile 355.006 Medullary Tube 355.042 2.5 mm Guide Rod with smooth tip, 950 mm 399.42 Hammer, 500 grams 511.30 Radiolucent Drive 511.414 3.2 mm Three-Fluted Drill Bit, brad point, 150 mm 511.417 4.0 mm Three-Fluted Drill Bit, brad point, 150 mm 511.701 Compact Air Drive II Titanium Tibial Nail System Surgical Technique DePuy Synthes Trauma

CAUTION: Federal Law Restricts These Devices To Sale By Or On The Order Of A Physician. Some devices listed in this technique guide may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. Manufactured by (United States): Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 Legal manufacturer (Canada): Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185 www.depuysynthes.com DePuy Synthes Trauma, a division of DOI 2014. All rights reserved. DSUS/TRM/0814/0217 8/14