Humerus shaft - Reduction & Fixation - Compression plate - AO Surgery Reference. Compression plating

Similar documents
Open reduction; plate fixation 1 Principles

Surgical Technique. Distal Humerus Locking Plate

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

Surgical Technique. Proximal Humerus Locking Plate

Surgical Technique. Olecranon Locking Plate

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

Zimmer Small Fragment Universal Locking System. Surgical Technique

Surgical Technique International Version. Clavicle Locking Plate

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

LCP Distal Tibia Plate

LCP Distal Humerus Plates

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

Surgical Technique. Clavicle Locking Plate

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

Technique Guide. PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.

SMV Scientific Bone Plate and Screw System Surgical Technique

Midfoot - Reduction & Fixation - ORIF - screw fixation - AO Surgery Reference. ORIF - screw fixation

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

NCB Proximal Humerus Plating System

3.5 mm LCP Extra-articular Distal Humerus Plate

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Conventus CAGE PH Surgical Techniques

Surgical Technique. Calcaneal Locking Plate

Surgical Technique. Lower Extremity Plates and Straight Plates

2.7 mm/3.5 mm Variable Angle LCP Elbow System DJ9257-B 1

Olecranon Locking Plate II

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

PROXIMAL TIBIAL PLATE

Instrument and Implant for wrist fracture

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

Technique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System.

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Surgical Technique. Locking Small Fragment Overview

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

tep Ankle Fracture Plating System

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

3.5 mm LCP Clavicle Hook Plates

Low Bend Distal Tibia Plates

DISTAL ELBOW SET. proximal ulna plate SURGICAL TECHNIQUE GUIDE

Zimmer Periarticular Proximal Humeral Locking Plate

Surgical Technique Guide PANTERA. Proximal Humerus Fracture Fixation Plate System

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

Small Fragment Plating System. Securing optimal fixation through locked and compression plating technology

Locking Radial Head Plates

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

Technique Guide. DCP and LC-DCP Systems. Dynamic Compression Plates (DCP) and Dynamic Compression Plates with Limited Bone Contact (LC-DCP).

Small Fragment Plating System

Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate

Fracture fixation. Types. Mechanical considerations. Biomechanics of fracture fixation. External fixation. Internal fixation

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

3.5 mm LCP Olecranon Plates

WINSTA-C. Clavicle Plating System

Technique Guide. ARCH Laminoplasty System. Dedicated System for Open-door Laminoplasty.

Simply Complete. VA-LCP Elbow Plating System.

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4)

3.5 mm Locking Attachment Plate

Biomet Large Cannulated Screw System

AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Zimmer Small Fragment Universal Locking System

Pre-Operative Planning. Positioning of the Patient

2.7 mm/3.5 mm LCP Distal Fibula Plate

Technique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.

Part of the DePuy Synthes Locking Compression Plate (LCP ) System. 3.5 mm LCP Medial Proximal Tibia Plates

3.5 mm LCP Distal Humerus Plates

Treatment Approach To Cases Of Nonunion Intercondylar Fracture Humerus

INTERNAL FIXATION OF THE METACARPALS AND PHALANGES P. BURGE

Surgical Technique International Version

AxSOS Locking Plate System

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

BICEPTOR Tenodesis System

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

CSLP-Cervical Spine Locking Plate

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

Merete BLP. Surgical Technique. - Bunion Locking Plate - Low Profile Locking Bone Plate System

Clinical. Solutions. Synthes Solutions. Foot and Ankle.

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

The Flower Proximal Humerus Plate

ARCH Laminoplasty System. Dedicated System for Open-door Laminoplasty.

Elbow Hinge Fixator. Guided Flexion/Extension for Unstable Elbow Fractures.

VariAx Compression Plating System. Operative technique

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

Increasing surgical freedom Restoring patient function

AcUMEDr. FoREARM ROD SYSTEM

Transcription:

Humerus shaft 12-A3 ORIF 1. Principles Compression plating Authors Compression plate Compression plating provides fixation with absolute stability for two-part fracture patterns, where the bone fragments can be compressed. Compression plating is typically used for simple fracture patterns with low obliquity, where there is insufficient room for a lag screw. The alternative plate fixation technique, used when fragments can not be compressed, is bridge plating. The objective of compression plating is to produce absolute stability, abolishing all interfragmentary motion. Dynamic compression principle https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 1 of 18

Compression of the fracture is usually produced by eccentric screw placement at one or more of the dynamic compression plate holes. These holes are shaped like an inclined and transverse cylinder. The screw head slides down the inclined cylinder as it is tightened, the head forcing the plate to move along the bone, thereby compressing the fracture. Plate length https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 2 of 18

It is crucial to use a plate that is long enough on each side of the fracture. Plate length is more important for ensuring stability than is the number of screws. 2. Plate position Plate location https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 3 of 18

The humerus has an anterolateral, a posterior, and a medial surface to each of which a plate can be applied. The location of the fracture will determine where the surgeon chooses to apply a plate to the humerus. The position of the plate is selected according to fracture location, and the length of proximal and distal main segments. The location should allow sufficient plate length on both proximal and distal segments, with a minimum of 4 holes for each. An anterolateral plate fits well from very proximally to the distal fifth of the humerus. The posterior surface is difficult to access proximally and is best suited for middle and distal third fractures. Once a location for the plate has been selected, the surgical approach is determined by that location. For proximal fractures, an anterolateral plate location and anterolateral surgical exposure are usual. For distal fractures, a posterior plate location is preferred. This area can be accessed with either a posterolateral, or a posterior, approach. In the central portion of the humerus, the plate can be applied to the anterolateral, lateral, or posterior surfaces, with the approach dependent on the preferred plate location. The medial surface is generally reserved for complex reconstructive procedures. Lateral plating https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 4 of 18

An anterolateral approach is chosen for proximal and middle third fractures, and allows supine patient positioning. The lateral approach can also be used, particularly if the most proximal part of the humerus need not be exposed. Distally, the plate may lie deep to the radial nerve. Posterior plating https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 5 of 18

A posterior approach will generally be chosen for more distal fractures. It is important to protect the radial nerve and its accompanying vessels in the spiral groove. Typically, a posterior plate must be placed underneath the radial nerve, to gain proximal bone anchorage. Note (a) It is possible to extend an anterolateral approach to access the posterior surface of the distal humerus. (b) It is mandatory to record accurately in the operation record the exact relationship of the radial nerve to the plate - either by a precise drawing, or by recording the plate hole numbers (counted from proximal to distal) where the nerve lies. This will reduce the risk of accidental nerve damage if the plate should ever need to be removed. 3. Reduction Manual reduction https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 6 of 18

Reduction should begin with limb realignment. This manipulative reduction takes advantage of soft tissue tension. Traction on the distal humerus restores bone length and tension in the soft tissues, and realigns the axis. Rotation must also be corrected. Interposed soft tissue may interfere with bone contact. If so, this will need to be cleared by direct exposure, preserving as much soft tissue attachment as possible. Reduction by external fixator or distractor https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 7 of 18

Sometimes traction can helpfully be provided by an external fixator, or distractor. The two pins should be inserted outside the planned plate location. Complete reduction may require additional correction of angulation or rotation. Folded linen bolsters under the fracture often help. Final reduction With suitable external supports, tissue tension usually maintains reduction of transverse (A3) fractures. The reduction may need final adjustment after the plate is applied provisionally to one bone fragment. It is important that the reduction be as close to anatomical as possible, in order to provide optimal fracture surface contact. 4. Contouring the plate Fitting the plate to the bone https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 8 of 18

Depending on the planned plate location, some contouring of the plate may be necessary. This is true distally, posteriorly, and also on the anterolateral surface centrally. Sometimes twisting the plate around the shaft of the humerus can provide a better fit, and allow a longer plate. Contouring is aided by a stable provisional reduction and a malleable template that can easily be shaped to the bone surface. The template is then used as a guide to shaping the plate to the bone. Overbending the plate https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 rative&method=orif%20-%20open%20reduction%20internal%20fixation Page 9 of 18

With short oblique and transverse fractures, the plate should be slightly overbent (more convex) so that it does not fit perfectly on the bone. As the eccentrically placed screws are tightened in an overbent plate, the far (trans) cortex is compressed first. With further tightening, the near (cis) cortex also becomes compressed. Such short, convex overbends can be made with the handheld bending pliers or bending irons. The overbend should lie directly over the fracture line. When the fracture is oblique enough, one should insert a lag screw through the plate. Slight overbending still helps to keep the fracture surfaces together, and the lag screw increases stability. Pitfall: Fracture opening opposite plate https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 10 of 18

When a transverse or short oblique fracture is compressed with a plate, this eccentric plate compresses the bone under the plate, but causes gapping on the side opposite the plate (trans cortex). This gapping, and its consequent associated micromotion, can be prevented by overbending the plate to achieve compression of the opposite side first. An alternative solution can be to insert a lag screw through the plate, across the fracture plane, as discussed below. This technique will also prevent gapping and micromotion. In single plane fractures, such as this example, micromotion results in excessive strain of the healing tissues at the fracture site and also risks plate fatigue failure if union is slow. 5. Plate fixation Application of the plate https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 11 of 18

No periosteal stripping should be done for plate fixation. However, there must be adequate soft tissue exposure to provide an appropriate area for the plate. The plate should be positioned over the fracture so that at least four holes can be used in each proximal and distal pieces. Some compromise may be necessary for very proximal or distal fractures. It is often helpful to hold the plate to the bone with one well-placed screw in order to confirm that it is contoured correctly. Drilling for the first screw https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 12 of 18

Remembering the desired plate position, drill a pilot hole approximately 8 mm away from the fracture. Its depth should be measured and then the thickness of the plate added to determine screw length. Its depth can alternatively be measured through the plate. Now tap if non-selftapping screws will be used. Application of the plate with a first screw https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 13 of 18

Attach the plate with one screw to the pre-drilled fragment. Do not tighten the screw completely. Check plate fit and alignment, and the fracture reduction. If satisfactory, proceed to drill the other fragment. Insert a second screw eccentrically https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 14 of 18

A second screw is inserted eccentrically into the other fragment, near the fracture. Tightening the eccentrically placed screw moves the plate, thereby compressing the fracture. Confirm that the fracture surfaces are reduced, and that both ends of the plate fit satisfactorily. Tighten screws to compress fracture https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 15 of 18

Tighten both screws alternately, watching carefully to see that the reduction is maintained and compressed satisfactorily. Finish screw insertion https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 16 of 18

The remaining screws are then inserted. Screws closest to the fracture site are inserted first. The humerus has a thin cortex and may be osteoporotic, in which case it may be safer to fill all the screw holes. In the past, the broad plate has been recommended to allow staggered screw holes. This is not necessary, but the screws should be inserted divergently to achieve this effect on the far cortex. Note Beware of harming the radial nerve Appendix Shortcuts All Preparations All Approaches All Reductions & Fixations Decision support https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 17 of 18

OTD Evidence report: Timing of wound debridement in open fractures Further reading Principles of diaphyseal fracture management Principles of surgical reduction Biomechanical principles: Absolute stability Decision making in severe soft-tissue trauma Contact Disclaimer AO Foundation v1.0 2006-09-14 https://www2.aofoundation.org/wps/portal/!ut/p/c0/04_sb8k8xllm9 ative&method=orif%20-%20open%20reduction%20internal%20fixation Page 18 of 18