Heart failure is a highly prevalent disorder with considerable

Similar documents
Sleep Apnea in 81 Ambulatory Male Patients With Stable Heart Failure. Types and Their Prevalences, Consequences, and Presentations

Chronic NIV in heart failure patients: ASV, NIV and CPAP

EFFECT OF THEOPHYLLINE ON SLEEP-DISORDERED BREATHING IN HEART FAILURE AND G.A. ROSELLE, M.D. The New England Journal of Medicine

Sleep Disordered Breathing: Beware Snoring! Dr T A McDonagh Consultant Cardiologist Royal Brompton Hospital London. UK

Key words: circulatory delay; congestive heart failure; obstructive sleep apnea; periodic breathing

Central Sleep Apnea, Right Ventricular Dysfunction, and Low Diastolic Blood Pressure Are Predictors of Mortality in Systolic Heart Failure

Edoardo Gronda UO cardiologia e Ricerca Dipartimento Cardiovascolare IRCCS MultiMedica

Mario Kinsella MD FAASM 10/5/2016

OSA and cardiovascular disease what is the evidence? Mohan Edupuganti, MD, FACC. Baptist Health Cardiology. Disclosures: None

A 74-year-old man with severe ischemic cardiomyopathy and atrial fibrillation

Sleep and the Heart. Physiologic Changes in Cardiovascular Parameters during Sleep

Sleep and the Heart. Rami N. Khayat, MD

A Deadly Combination: Central Sleep Apnea & Heart Failure

ABSTRACT Background Breathing is controlled by a negative-feedback

Opioids Cause Central and Complex Sleep Apnea in Humans and Reversal With Discontinuation: A Plea for Detoxification

Sleep and the Heart Reversing the Effects of Sleep Apnea to Better Manage Heart Disease

Novel pathophysiological concepts for the development and impact of sleep apnea in CHF.

Sleep Apnea and Cardiovascular Risk. Presented by Akshay Mahadevia, M.D. Diplomate American Board of Sleep Medicine

The Effect of Sleep Disordered Breathing on Cardiovascular Disease

Despite recent advances in the pharmacological therapy of

Sleep apnea and congestive heart failure (CHF) are common

Sleep Apnea Syndrome in Patients with Atrial Fibrillation 2 Cases Whose Atrial Fibrillation Was Controlled by Treatment for Sleep Apnea Syndrome

Basics of Polysomnography. Chitra Lal, MD, FCCP, FAASM Assistant professor of Medicine, Pulmonary, Critical Care and Sleep, MUSC, Charleston, SC

Timing of Nocturnal Ventricular Ectopy in Heart Failure Patients With Sleep Apnea*

Heart Failure and Sleep Disordered Breathing (SDB) Unhappy Bedfellows

AHA Sleep Apnea and Cardiovascular Disease. Slide Set

Effects of Home Oxygen Therapy on Patients With Chronic Heart Failure

PVDOMICS. Sleep Core. Cleveland Clinic Cleveland, Ohio

SLEEP DISORDERED BREATHING The Clinical Conditions

Treatment of central sleep apnoea in congestive heart failure with nasal ventilation

6/5/2017. Mellar P Davis MD FCCP FAAHPM Geisinger Medical Center Danville, PA

New Government O2 Criteria and Expert Panel. Jennifer Despain, RPSGT, RST, AS

Sleep and the Heart. Sleep Stages. Sleep and the Heart: non REM 8/31/2016

Prognosis of Patients With Heart Failure and Obstructive Sleep Apnea Treated With Continuous Positive Airway Pressure*

Atrial Overdrive Pacing for the Obstructive Sleep Apnea Hypopnea Syndrome

Nighttime is a vulnerable time for death from. The Relationship Between Congestive Heart Failure, Sleep Apnea, and Mortality in Older Men*

Sleep apnea in 81 ambulatory male patients with stable heart failure. Types and their prevalences, consequences, and presentations

In-Patient Sleep Testing/Management Boaz Markewitz, MD

Sleep Apnea: Diagnosis & Treatment

In the first part of this 2-part review, we provided a synopsis

The introduction of ACE inhibitors, whose beneficial

Apnea Hypopnea Threshold for CO 2 in Patients with Congestive Heart Failure

During the therapeutic titration of nasal continuous

Σύνδρομο σπνικής άπνοιας. Ποιός o ρόλος ηοσ ζηη γένεζη και ανηιμεηώπιζη ηων αρρσθμιών;

Association of Nocturnal Cardiac Arrhythmias with Sleep- Disordered Breathing

Reviews. Introduction. Methods. with SDB and heart failure, and a meta-analysis of these published data was done.

Prevalence of Sleep Disordered Breathing in Congestive Heart Failure as Determined by ApneaLink, a Simplified Screening Device

The AASM Manual for the Scoring of Sleep and Associated Events

University, India.) Corresponding author: Dr. Shubham Agarwal1

(To be filled by the treating physician)

Diagnostic Accuracy of the Multivariable Apnea Prediction (MAP) Index as a Screening Tool for Obstructive Sleep Apnea

Central sleep apnea (CSA) with Cheyne-Stokes respiration, Heart Failure

Index SLEEP MEDICINE CLINICS. Note: Page numbers of article titles are in boldface type.

Dr. Karan Madan Senior Resident

Portable Sleep Testing in Hospitalized Patients

Treatment of Cheyne-Stokes Respiration in Patients with Congestive Heart Failure

Clinical update of BiPAP autosv for treatment of Sleep Disordered Breathing

Heart Failure Update John Coyle, M.D.

Sleep Apnea and Heart Failure

Relationship Between Sodium Intake and Sleep Apnea in Patients With Heart Failure

Association of Smoking, Sleep Apnea, and Plasma Alkalosis With Nocturnal Ventricular Arrhythmias in Men With Systolic Heart Failure

The Sleep-Stroke Connection: An Under-recognized Entity. Simin Khavandgar MD UPMC Neurology Department

About VirtuOx. Was marketed exclusively by Phillips Healthcare division, Respironics for 3 years

Sleep Apnea and chronic Heart Failure

Increasing the Functional Residual Capacity May Reverse Obstructive Sleep Apnea

The most accurate predictors of arterial hypertension in patients with Obstructive Sleep Apnea Syndrome

3/10/2014. Pearls to Remember. 1) Consequences of OSA related to both arousals and hypoxia. 2) Arousals provoke increased

I n normal healthy subjects asymptomatic ventricular premature

Heart Failure (HF) Treatment

Heart failure is a highly prevalent problem

Central sleep apneas: Definition, etiology and evidence based management Dr Nandakishore B

Overnight fluid shifts in subjects with and without obstructive sleep apnea

Diabetes & Obstructive Sleep Apnoea risk. Jaynie Pateraki MSc RGN

ORIGINAL ARTICLES. Adaptation to Nocturnal Intermittent Hypoxia in Sleep-Disordered Breathing: 2,3 Diphosphoglycerate Levels: A Preliminary Study

Using the Pathophysiology of Obstructive Sleep Apnea (OSA) to Teach Cardiopulmonary Integration

Circadian Variations Influential in Circulatory & Vascular Phenomena

RESEARCH PACKET DENTAL SLEEP MEDICINE

Cardiovascular Effects of Continuous Positive Airway Pressure in Patients with Heart Failure and Obstructive Sleep Apnea

Obstructive sleep apnea (OSA) is the periodic reduction

MCOEM Spring Chapter Meeting April 5, Sleep Apnea An Overview with Emphasis on Cardiovascular Correlations Jacques Conaway, MD

Is CPAP helpful in severe Asthma?

Polysomnography (PSG) (Sleep Studies), Sleep Center

Multiple studies have consistently demonstrated an association SCIENTIFIC INVESTIGATIONS METHODS

DRS ed Aritmie Cardiache Iper ed Ipocinetiche: la clinica

Clinical Investigations

Nasal pressure recording in the diagnosis of sleep apnoea hypopnoea syndrome

Lateral Sleeping Position Reduces Severity of Central Sleep Apnea / Cheyne- Stokes Respiration

BTS sleep Course. Module 10 Therapies I: Mechanical Intervention Devices (Prepared by Debby Nicoll and Debbie Smith)

Philip L. Smith, MD; Christopher P. O Donnell, PhD; Lawrence Allan, BS; and Alan R. Schwartz, MD

GOALS. Obstructive Sleep Apnea and Cardiovascular Disease (OVERVIEW) FINANCIAL DISCLOSURE 2/1/2017

DECLARATION OF CONFLICT OF INTEREST

Obstructive sleep apnoea How to identify?

Obstructive Sleep Apnea

Κλινικό Φροντιστήριο Αναγνώριση και καταγραφή αναπνευστικών επεισοδίων Λυκούργος Κολιλέκας Επιμελητής A ΕΣΥ 7η Πνευμονολογική Κλινική ΝΝΘΑ Η ΣΩΤΗΡΙΑ

Sleep apnea as a risk factor for cardiovascular disease

In the last decade, there has been a major change in the management

Internet Journal of Medical Update

What is SDB? Obstructive sleep apnea-hypopnea syndrome (OSAHS)

Sleep Apnea: Vascular and Metabolic Complications

Transcription:

Effects of Continuous Positive Airway Pressure on Sleep Apnea and Ventricular Irritability in Patients With Heart Failure S. Javaheri, MD Background Patients with heart failure and systolic dysfunction may develop disordered breathing during sleep. Repeated episodes of apnea and hypopnea may result in desaturation and arousals, which could adversely affect left ventricular function. The purpose of this study was to determine the short-term effects of continuous positive airway pressure (CPAP) on sleep-disordered breathing and its consequences in heart failure patients. Methods and Results The author prospectively studied 29 male patients whose initial polysomnograms showed 15 or more episodes of apnea and hypopnea per hour (apnea-hypopnea index, AHI). Twenty-one patients had predominately central and 8 patients obstructive sleep apnea. All were treated with CPAP during the subsequent night. In 16 patients, CPAP resulted in virtual elimination of disordered breathing. In these patients, the mean AHI (36 12 [SD] versus 4 3 per hour, P 0.0001), arousal index due to disordered breathing (16 9 versus 2 2 per hour, P 0.0001), and percent of total sleep time below saturation of 90% (20 23% to 0.3 0.7%, P 0.0001) decreased, and lowest saturation (76 8% versus 90 3%, P 0.0001) increased with CPAP. In 13 patients who did not respond to CPAP, these values did not change significantly. In patients whose sleep apnea responded to CPAP, the number of hourly episodes of nocturnal premature ventricular contractions (66 117 versus 18 20, P 0.055) and couplets (3.2 6 versus 0.2 0.21, P 0.031) decreased. In contrast, in patients whose sleep apnea did not respond to CPAP, ventricular arrhythmias did not change significantly. Conclusions In 55% of patients with heart failure and sleep apnea, first-night nasal CPAP eliminates disordered breathing and reduces ventricular irritability. (Circulation. 2000;101:392-397.) Key Words: nervous system, sympathetic heart failure respiration hypoxia Heart failure is a highly prevalent disorder with considerable morbidity and mortality despite advancements in its therapy. A recent systematic study in patients with treated, stable heart failure with left ventricular systolic dysfunction reported that 50% had periodic breathing during sleep. 1 Periodic breathing (defined as a pattern of breathing consisting of periodically recurring cycles of apnea or hypopnea followed by hyperpnea) may result in arterial oxyhemoglobin desaturation, excessive arousals, and changes in intrathoracic pressure. 1 3 If left untreated, the pathophysiological consequences of periodic breathing could affect cardiac function adversely, contributing to an increase in morbidity and mortality of patients with heart failure. 4 In a study reported from this laboratory, 1 we found that heart failure patients with sleep apnea had a lower left ventricular ejection fraction and a higher prevalence of atrioventricular arrhythmias than patients without periodic breathing; the cause and effect, however, could not be determined. Nasal continuous positive airway pressure (CPAP) devices are well known to prevent upper airway occlusion, which occurs in obstructive sleep apnea (OSA). 5 7 These devices have been successfully used to treat OSA in patients without heart failure. More recently, CPAP devices have been used for treatment of sleep apnea in patients with heart failure and systolic dysfunction. 8 10 With regard to treatment of central sleep apnea (CSA), the most common form of disordered breathing in heart failure, although the results from one center have been promising, 8 2 other centers 9,10 reported no significant beneficial effects of CPAP on CSA. During the past few years, we have been involved in studies of periodic breathing in a relatively large number of patients with heart failure resulting from systolic dysfunction. 1,11 We have studied patients who were ambulatory and stable on standard therapy for heart failure, with no other major disorders (eg, chronic obstructive lung disease). Patients who were found to have an apnea-hypopnea index (AHI) of 15 per hour were subsequently treated with CPAP and are the subject of this report. Methods The patients in the current study belonged to the pool of 81 patients with stable heart failure and left ventricular systolic dysfunction (left Received June 9, 1999; revision received August 18, 1999; accepted August 31, 1999. From the Sleep Disorders Laboratory, Department of Veterans Affairs Medical Center, and Department of Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio. Reprint requests to S. Javaheri, MD, Pulmonary Section (111F), VA Medical Center, Cincinnati, OH 45220. E-mail javaheri.shahrokh@cincinnati.va.gov 2000 American Heart Association, Inc. Circulation is available at http://www.circulationaha.org 392

Javaheri CPAP in Heart Failure 393 ventricular ejection fraction 45%) who have been described in detail previously. 1,11 Twenty-nine of these patients whose initial polysomnograms showed an AHI of 15 per hour were subsequently treated with CPAP. All patients were clinically stable (no change in symptoms of heart failure or their medications within the previous 4 weeks) and on standard therapy, including an angiotensin-converting enzyme inhibitor (23 patients), hydralazine (4 patients), digoxin (23 patients), isosorbide dinitrate (12 patients), and diuretics (26 patients). Exclusion criteria have been detailed previously 1,11 and included major comorbid disorders (such as chronic obstructive pulmonary disease and known intrinsic liver and renal disorders) and use of morphine derivatives, benzodiazepines, theophylline, and acetazolamide. For uniformity, only male patients were studied: female patients are seldom referred to this center. Polysomnography On the first night, the patients slept in the sleep laboratory after electrodes had been placed, with the intention of familiarizing them with the environment of the sleep laboratory. On the second night, polysomnography was performed using standard techniques as detailed previously. 12 13 For staging sleep, we recorded electroencephalogram (2 channels), chin electromyogram (1 channel), and electro-oculogram (2 channels). Thoracoabdominal excursions and naso-oral airflow (measured by a thermocouple) were measured qualitatively. Arterial blood oxyhemoglobin saturation was recorded using an oximeter. The output of pulse oximeter at 0 V was considered 0% saturation and at 1 V, 100% saturation. The voltage calibration was performed several times throughout each study. The variables were recorded on a multichannel polygraph (Model 78D; Grass Instrument Company). 1,11 13 An apnea was defined as cessation of inspiratory airflow for 10 seconds. All such events were counted irrespective of the degree of desaturation or presence of an arousal. An obstructive apnea was defined as the absence of airflow in the presence of rib cage and/or abdominal excursions. A central apnea was defined as the absence of rib cage and abdominal excursions with absence of airflow. It is noted, however, that in the absence of measurements of esophageal pressure, it is sometimes difficult to truly distinguish a central apnea from an obstructive apnea. Hypopnea was defined as a discernible reduction in airflow or thoracoabdominal excursions lasting 10 seconds and resulting in an arousal 14 or at least a 4% drop in arterial oxyhemoglobin saturation. The author classified hypopnea as obstructive if paradoxical thoracoabdominal excursions occurred or if the airflow decreased out of proportion to the reduction in the thoracoabdominal excursions. The number of episodes of apnea and hypopnea per hour of sleep is referred to as the AHI. Similarly, the number of episodes of arousal per hour of sleep is referred to as the arousal index. The patients were classified to have predominately OSA- or CSA-hypopnea as defined earlier. 1 In patients with predominately CSA, the obstructive AHI had to be 10 per hour; at least 50% of the disordered breathing events were classified as central. In these patients, the obstructive AHI varied from 0.0 to 9.1 per hour. In patients with predominately OSA, obstructive AHI had to be 10 per hour, and it represented at least 50% of the disordered breathing events. In these patients the obstructive AHI varied from 19.9 to 35.3 per hour. All polysomnograms were scored blindly. CPAP Titration Patients who had an AHI 15 were studied during the third night in the sleep laboratory with CPAP. Titration began with 5 cm H 2 O, and the pressure was progressively and gradually increased by 1 cm H 2 O every 15 minutes, to eliminate episodes of apnea, hypopnea, desaturation, and arousal. Pressure was decreased, at the patient s request if awakening occurred, and titration was resumed as the patients fell asleep. We had the intention to discontinue CPAP if patients complained of dizziness or chest discomfort. For the purpose of this study, we defined individuals whose AHI on CPAP decreased to 15 per hour, CPAP-responsive. This was the threshold we used to define presence of clinically significant sleep apnea. 1 In all these patients, the AHI decreased by 50%. Other Studies To determine the prevalence of arrhythmia and its response to CPAP, Holter monitoring was performed during polysomnography, as detailed previously. 14 In this study, 16 patients had paired Holter recordings. Ventricular tachycardia was defined as the presence of 3 ventricular premature beats in a row. Right and left ventricular ejection fractions were calculated from gated first pass and multigated radionuclide ventriculograms, respectively, using standard techniques. Pulmonary function tests and arterial blood samples were obtained as detailed previously. 1,13 These studies were approved by the Institutional Review Board at the University of Cincinnati, and written informed consent of each patient was obtained. Statistical Analysis We used the Wilcoxon rank sum test for paired and Mann-Whitney U statistic for unpaired data, because our data were not normally distributed; 2 was used for comparison of proportions. A 2-tail P value 0.05 was considered significant. Values are reported as mean SD. Calculations were done using GraphPad Instat V2.03. Results There were 29 heart failure patients, 8 with OSA and 21 with CSA. Fifty-five percent (16 of 29) patients responded to CPAP, 7 with OSA and 9 with CSA. Patients with OSA were significantly heavier and had a higher prevalence of habitual snoring than patients with CSA (Table 1). In patients with OSA, application of nasal CPAP resulted in significant improvement in disordered breathing and arterial oxyhemoglobin desaturation, with a significant drop in arousals due to periodic breathing (Figure 1). These arousals decreased from 22 10 to 3 3 per hour and accounted for most of the decrease in overall arousal index from 42 31 to 14 9 per hour (P 0.008). Sleep stages did not change significantly. CPAP values varied from 5 to 18 cm H 2 O, with a mean of 8 5 cmh 2 O. In one patient with predominate OSA (AHI 54 per hour, obstructive AHI 35 per hour, and central apnea index 14 per hour), CPAP resulted in elimination of all obstructive episodes (index 0.0 per hour), but episodes of central apnea increased (central apnea index increased to 21 per hour with CPAP). This patient was considered nonresponsive to CPAP. There were 21 patients with CSA, 9 of whom responded to CPAP (43% of patients with CSA). CPAP significantly improved disordered breathing and arterial oxyhemoglobin desaturation with a significant decrease in the number of arousals due to periodic breathing (Figure 2). These arousals decreased from 12 8 to 2 2 per hour (Figure 2) and accounted for the decrease in the overall arousal index from 21 16 to 11 9 per hour (P 0.098). There were no significant changes in sleep stages, however. The CPAP values varied from 5 to 12 cm H 2 O and the mean was 7 2 cmh 2 O. In the 12 heart failure patients with CSA who did not respond to CPAP, the mean values for AHI (62 22 versus 62 29 per hour, baseline versus CPAP, respectively), central apnea index (43 21 versus 49 21 per hour), total dark time (397 21 versus 383 43 minutes), total sleep time (255 51 versus 212 83 minutes), most sleep stages, and arousal index (40 27 versus 40 31 per hour) did not change significantly. However, CPAP modestly improved arterial oxyhemoglobin desaturation with percent total sleep time below 90% decreasing from 30 17% to 9 15%, P 0.02). Values for CPAP varied from 5 to 18 cm H 2 O, and the mean was 13 4 cmh 2 O.

394 Circulation February 1, 2000 TABLE 1. Demographics, Arterial Blood Gas Values, Left Ventricular Ejection Fraction, and Disordered Breathing Events in Heart Failure Patients With OSA and CSA OSA (n 8) CSA (n 21) P CSA- Nonresponsive (n 12) CSA- Responsive (n 9) Age, y 61 10 66 9 0.2 65 10 68 8 1.0 Height, cm 175 5 174 8 0.7 173 8 174 8 0.8 Weight, kg 111 29 85 19 0.02 82 18 90 21 0.4 Body mass 36 8 28 5 0.02 27 5 29 5 0.3 index, kg/m 2 Habitual 88 50 0.07 50 50 1.0 snoring, % PO 2,mmHg 77 11 84 9 0.1 84 9 84 10 0.9 PCO 2,mmHg 41 6 37 4 0.048 35 4 38 4 0.2 LVEF, % 26 7 22 9 0.1 20 6 25 11 0.3 SBP, mm Hg 132 20 122 19 0.3 120 16 127 22 0.6 DBP, mm Hg 79 12 72 11 0.1 72 12 73 9 0.4 AHI, n/hr 37 9 51 23 0.09 62 22 36 15 0.01 OAI, n/hr 8 10 1 2 0.01 0.4 1.2 1.7 2.9 0.03 OAHI, n/hr 28 6 1 3 0.0001 1.0 2.6 2.1 3.1 0.05 CAI, n/hr 4 5 34 21 0.0001 43 21 23 15 0.02 SBP indicates systolic blood pressure; DBP, diastolic blood pressure; LVEF, left ventricular ejection fraction; OAHI, obstructive apnea-hypopnea index; and CAI, central apnea index. Values are mean SD. P Although there were significant differences in demographics of patients with OSA versus CSA (Table 1), demographics of heart failure patients with CSA who did not respond to CPAP did not differ from those who did (Table 1). However, the AHI was significantly higher in nonresponsive than responsive patients (Table 1). In patients whose sleep apnea responded to CPAP, the number of premature ventricular contractions, couplets, and ventricular tachycardias decreased with CPAP (Table 2). In contrast, CPAP had no significant effect on ventricular irritability in patients whose disordered breathing did not improve (Table 2). Discussion This is the largest study of the effects of CPAP on sleepdisordered breathing in patients with stable, treated heart failure and systolic dysfunction. There were 29 heart failure patients with sleep apnea, 55% of whom (16 of 29 patients) responded significantly to CPAP. In these patients, AHI, arousal index, and arterial oxyhemoglobin saturation improved. Ventricular arrhythmias also improved in patients whose disordered breathing responded to CPAP; there was no significant change in nonresponders. Figure 1. Polysomnographic findings in 8 heart failure patients with OSA with and without continuous positive airway pressure CPAP. OAHI indicates obstructive apnea-hypopnea index; SaO 2, arterial oxyhemoglobin saturation; TDT, total dark time; TST, total sleep time; WASO, wakefulness after sleep onset; SE, sleep efficiency; DBArI, arousal index due to disordered breathing.

Javaheri CPAP in Heart Failure 395 Figure 2. Polysomnographic findings in 9 heart failure patients with CSA with and without CPAP. CAI indicates central apnea index; all other abbreviations as in Figure 1. Effects of CPAP in Heart Failure Patients With OSA In 8 patients with OSA, application of nasal CPAP (8 5 cm H 2 O) resulted in a significant reduction in AHI from 37 to 5 per hour (Figure 1). As a result, arousal index due to sleep apnea and hypopnea decreased significantly from 22 to 3 per hour, and time below saturation of 90% decreased from 31% of the total sleep time to 1% (Figure 1). Continuous positive airway pressure is known to maintain upper airway patency by increasing transmural pressure of upper airways. 5 7 The relief of upper airway occlusion in heart failure patients with OSA should be similar to OSA patients without heart failure. However, therapeutic implications of improvement in obstructive apnea-hypopnea in the setting of heart failure with established left ventricular systolic dysfunction and/or coronary artery disease could be different from those in OSA without heart failure. These may include several factors, 3,4 such as improved myocardial oxygen delivery, decreased sympathetic activity, left ventricular transmural pressure, and afterload. TABLE 2. Effects of CPAP on Ventricular Arrhythmias, Arousals, and Oxyhemoglobin Saturation During Sleep in Heart Failure Patients With Sleep Apnea CPAP-Nonresponsive Effects of CPAP on Heart Failure Patients With CSA In 43% (9 of 21) of the patients with CSA, application of CPAP (7 2 cmh 2 O) resulted in virtual normalization of disordered breathing (Figure 2). In these patients, the average AHI decreased from 36 to 4 per hour and central apnea index decreased from 23 to 2 per hour. As a result, arterial oxyhemoglobin desaturation was virtually eliminated and arousal index decreased considerably from 21 to 11 per hour. The latter was due to reduction in disordered breathing related arousal index, which decreased from 12 to 2 per hour (P 0.008). Despite considerable improvement in periodic breathing, CPAP failed to improve sleep efficiency and wakefulness after sleep onset. This appears to be unique to patients with heart failure, both with OSA and CSA even after long-term use. 8 In contrast, even short-term application of CPAP in OSA without heart failure usually improves sleep characteristics. 5 The majority of patients with heart failure and CSA failed to acutely respond to CPAP. We progressively increased CPAP-Responsive Baseline CPAP P Baseline CPAP P PVCs, n/h 223 357 192 321 0.1 66 117 18 20 0.054 Couplets, n/hr 4.7 9 5 8 0.2 3.2 6 0.2 0.2 0.031 VT, n/hr 0.4 1 0.9 2 0.3 1.1 3.2 0.05 0.1 1.0 Baseline SaO 2 96 1 95 3 0.5 95 2 97 1 0.016 Lowest SaO 2,% 74 12 86 6 0.04 79 5 91 3 0.008 SaO 2 90%, %TST 31 17 12 17 0.2 10 9 0.06 0.2 0.008 ArI, n/hr 31 25 36 31 0.5 19 13 9 6 0.023 PVCs indicates premature ventricular contractions; VT, ventricular tachycardias; SaO 2, saturation measured by pulse oximetry; TST, total sleep time; ArI, arousal index. Two patients in the CPAP-responsive group had OSA, and the remaining patients had CSA; n 8 in each group. Values are mean SD.

396 Circulation February 1, 2000 CPAP level to eliminate central apnea. However, the number of episodes of central apnea remained relatively unchanged (see Results). Upper airway occlusion is known to occur in patients with CSA, 15 and Issa and Sullivan 16 showed that high level (9 to 16.5 cm H 2 O) CPAP was required to eliminate CSA in patients without known left ventricular systolic dysfunction. In the present study in heart failure patients with CSA, we increased the pressure hoping to prevent CSA, but high level CPAP failed to eliminate these apneas in 57% of the patients and the mean AHI and central apnea index remained unchanged. These data suggest that even if upper airway collapse occurred in CSA, elimination of occlusion by CPAP did not eliminate CSA, indicating that pathogenesis of CSA and OSA differs at least in most patients with heart failure. This conclusion is further supported by the only patient with predominant episodes of OSA, which were completely eliminated by CPAP (obstructive AHI was zero); episodes of CSA increased (see Results). We can only speculate why in 57% of patients with heart failure, CSA does not respond to CPAP. We found no significant differences in any of the demographics between CPAP-responsive and nonresponsive (Table 1). The only significant difference, however, was that nonresponsive patients had a more severe sleep apnea than responsive patients (AHI 62 22 versus 36 15 per hour). In the face of severe CSA, during the periods of repetitive cyclical hyperventilation after episodes of central apnea, CPAP may result in arousability that promotes ventilatory instability. 17 Irrespective of the mechanism, however, severe CSA could be an important predictor of long-term CPAP nonresponsiveness in heart failure patients. Effects of CPAP on Ventricular Irritability During Sleep Comparing baseline to CPAP, there were no significant changes in the hourly rates of various ventricular arrhythmias in CPAP nonresponders (Table 2). However, in heart failure patients whose disordered breathing improved with CPAP, ventricular arrhythmias decreased. The hourly rate (during sleep) of premature ventricular contractions decreased from 66 to 18 (P 0.055), couplets from 3.2 to 0.2 per hour (P 0.031), and ventricular tachycardias from 1.1 to 0.05 per hour. We acknowledge that the number of patients was small (n 8 in each group) and normally there is considerable intra-individual variability in ventricular arrhythmias, yet the mean values of the various ventricular arrhythmias did not change significantly in CPAP nonresponders (Table 2). There are at least 2 explanations for reduction in ventricular irritability in CPAP-responsive patients. CPAP improved arterial oxyhemoglobin desaturation and the number of arousals (Table 2), both of which are associated with sympathetic overactivity. 18 23 In addition, improved saturation may have also improved myocardial oxygen delivery. Although we did not measure sympathetic activity, this has been shown repeatedly in various studies and under a variety of circumstances. The studies of Somers and colleagues have shown increased sympathetic activity with arousals in normal men 18 and men with central 19 and OSA. 20 Studies by Naughton and associates 23 have shown increased plasma norepinephrine concentration in heart failure patients with CSA when compared with heart failure patients without CSA; and application of nasal CPAP decreased both norepinephrine plasma concentration and urinary excretion. Furthermore, it has been shown that major ventricular arrhythmias are associated with and potentially caused by cardiac sympathetic overactivity. 24 Therefore, it is perhaps reasonable to speculate that the decrease in ventricular arrhythmias by CPAP was mediated by decreased sympathetic activity secondary to decrease in the number of arousals and improved saturation. Decreased sympathetic activity by CPAP also decreases systemic vascular resistance and transmural left ventricular pressure, the latter in part due to changes in intrathoracic pressure as well. 25 Thus, CPAP decreases left ventricular afterload resulting in an increase in left ventricular ejection fraction and improved pump failure. 8 Because sudden death, presumably caused by ventricular arrhythmias, and pump failure are the 2 major causes of death in heart failure patients, CPAP by decreasing ventricular arrhythmias, as noted in the present study, and improving ejection fraction 8 may improve survival in heart failure. Decreased cardiac output and hypotension are potential complications of CPAP. We did not monitor hemodynamics during sleep; however, in our study none of the patients complained of chest discomfort or dizziness with use of CPAP. Regarding safety of CPAP in heart failure patients, 2 points are emphasized. Our patients were ambulatory and stable, and no one was in class IV of New York Heart Association classification. Most importantly, CPAP was increased gradually by increments of 1 cm H 2 O. In contrast, in studies which have reported decreased cardiac output, CPAP was used at predetermined high pressures, eg, 10 cm H 2 O. One study using the latter approach reported that heart failure patients with atrial fibrillation were particularly sensitive to CPAP. 26 In our study, there were 5 patients with atrial fibrillation, and no one reported any adverse effects with gradual titration. Heart failure patients with low intravascular volume, receiving vasodilators or -blockers may not be able to increase venous return to compensate for the sudden increases in intrathoracic pressure. Our data in 29 heart failure patients suggest that gradual titration of CPAP is a safe procedure. We avoid application of CPAP at a predetermined pressure of 5 cmh 2 O to patients with heart failure. Limitations of This Study As noted in Methods, for uniformity only male subjects were studied. We therefore acknowledge that the results of this study may not necessarily be applicable to female patients with heart failure. As also noted in Methods, in the absence of esophageal pressure, classification of central versus obstructive disordered breathing events might have not been always accurate and some misclassification might have occurred. However, independent of the kind of sleep apnea, the results of this study show that CPAP virtually eliminated sleep-disordered breathing in 55% of the heart failure patients and improved ventricular arrhythmias. Therefore, the impact of this finding in a typical patient with heart failure and sleep apnea cannot be overemphasized.

Javaheri CPAP in Heart Failure 397 Meanwhile, regarding classification of disordered breathing into central versus obstructive disordered breathing, the results of our studies and others suggest that misclassification of events should be limited. In all our studies, polysomnograms were scored blindly. Afterward, when the disordered breathing events were matched with demographics of patients, we have consistently observed that those patients classified as OSA are significantly heavier and have a higher prevalence of snoring 1 than those classified as CSA (Table 1). Furthermore, with our pharmacological studies, eg, theophylline, 12,13 as expected, only disordered breathing events classified central in nature decreased, with episodes of obstructive apnea remaining unchanged. Finally, in a study using esophageal balloon, it was concluded that thoracoabdominal excursions (measured qualitatively by mercury strain gauges) alone had a positive predictive value of 0.96 for classifying central or obstructive apneas. 27 In summary, the results of this study show that CPAP is effective in eliminating sleep apnea in the majority of heart failure patients. As a result, arterial oxyhemoglobin saturation improves and the number of arousals and nocturnal ventricular irritability decrease. We speculate that long-term CPAP may favorably influence the natural history of heart failure and its morbidity and mortality. Acknowledgment This work was supported by Merit Review Grants from the Department of Veterans Affairs. References 1. Javaheri S, Parker TJ, Liming JD, Corbett WS, Nishiyama H, Wexler L, Roselle G. Sleep apnea in 81 ambulatory male patients with stable heart failure: types and their prevalences, consequences, and presentations. Circulation. 1998;97:2154 2159. 2. Yamashiro Y, Kryger MH. Sleep in heart failure. Sleep. 1993;16: 513 523. 3. Bradley TD, Floras JS. Pathophysiologic and therapeutic implications of sleep apnea in congestive heart failure. J Card Fail. 1996;2:223 240. 4. Javaheri S. Central sleep apnea-hypopnea syndrome in heart failure: prevalence, impact and treatment. Sleep. 1996;19:S229 231. 5. Sullivan CE, Issa FG, Berthon-Jones M, Eves L. Reversal of obstructive sleep apnea by continuous positive airway pressure applied through the nares. Lancet. 1981;1:862 865. 6. Rapoport DM, Sorkin B, Garay SM, Goldring RM. Reversal of pickwickian syndrome by long term use of nocturnal airway pressure. N Engl J Med. 1982;307:931 933. 7. Sanders MH, Moore SE, Eveselage J. CPAP via nasal mask: a treatment for occlusive sleep apnea. Chest. 1983;83:144 145. 8. Naughton NT, Liu PP, Bernard DC, Goldstein RS, Bradley TD. Treatment of congestive heart failure and Cheyne-Stokes respiration during sleep by continuous positive airway pressure. Am J Respir Crit Care Med. 1995;151:92 97. 9. Buckle P, Millar T, Kryger M. The effect of short-term nasal CPAP on Cheyne- Stokes respiration in congestive heart failure. Chest. 1992;102:31 35. 10. Davies RJO, Harrington KJ, Ormerod JM, Stradling JR. Nasal continuous positive airway pressure in chronic heart failure with sleep-disordered breathing. Am Rev Respir Dis. 1993;147:630 634. 11. Javaheri S, Parker TJ, Wexler L, Michaels SE, Stanberry E, Nishyama H, Roselle GA. Occult sleep-disordered breathing in stable congestive heart failure. Ann Intern Med. 1995;122:487 492. 12. Dowdell WT, Javaheri S, McGinnis W. Cheyne-Stokes respiration presenting as sleep apnea syndrome. Am Rev Respir Dis. 1990;141:871 879. 13. Javaheri S, Parker TJ, Wexler L, Liming JD, Lindower P, Roselle GA. Effect of theophylline on sleep-disordered breathing in heart failure. N Engl J Med. 1996;335:572 577. 14. ASDA Report. EEG arousals. Scoring rules and examples. Sleep. 1992; 15:174 184. 15. Badr MS, Toiber F, Skatrud JB, Dempsey J. Pharyngeal narrowing/occlusion during central sleep apnea. J Appl Physiol. 1995;78:1806 1815. 16. Issa FG, Sullivan CE. Reversal of central sleep apnea using nasal CPAP. Chest. 1986;90:165 171. 17. Dempsey JA, Smith CA, Harms CA, Chow CM, Saupe KW. Sleep and breathing. State of the art review: sleep induced breathing instability. Sleep. 1996;19:236 247. 18. Somers VS, Dyken M, Mark AL, Abboud FM. Sympathetic-nerve activity during sleep in normal subjects. N Engl J Med. 1993;238:303 307. 19. Van de Borne P, Oren R, Abouassaly C, Anderson E, Somers VK. Effect of Cheyne-Stokes respiration on muscle sympathetic nerve activity in severe congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy. Am J Cardiol. 1998;81:432 436. 20. Somers VK, Dyken M, Clary MP, Abboud FM. Sympathetic neural mechanisms in obstructive sleep apnea. J Clin Invest. 1995;96:1897 1904. 21. Davies RJO, Belt PJ, Roberts SJ, Ali NJ, Stradling JR. Arterial blood pressure responses to graded transient arousal from sleep in normal humans. J Appl Physiol. 1993;74:1123 1130. 22. Rose CE Jr, Althaus JA, Kaiser DL, Miller ED, Carey RM. Acute hypoxemia and hypercapnia: increase in plasma catecholamines in conscious dogs. Am J Physiol.1983;245:H924 H929. 23. Naughton MT, Benard DC, Liu PP, Rutherford R, Rankin F, Bradley TD. Effects of nasal CPAP on sympathetic activity in patients with heart failure and central sleep apnea. Am J Respir Crit Care Med. 1995;152:473 479. 24. Meredith IT, Broughton A, Jennings GL, Esler MD. Evidence of a selective increase in cardiac sympathetic activity in patients with sustained ventricular arrhythmias. N Engl J Med. 1991;325:618 624. 25. Tkacova R, Rankin F, Fitzgerald FS, Floras JS, Bradley TD. Effects of continuous positive airway pressure on obstructive sleep apnea and left ventricular afterload in patients with heart failure. Circulation. 1998;98:2269 2275. 26. Keily JL, Deegan P, Buckley A, Shiels P, Maurer B, McNicholas WT. Efficacy of nasal continuous positive airway pressure therapy in chronic heart failure: importance of underlying cardiac rhythm. Thorax. 1998;53:957 962. 27. Gold AR, Bleecker ER, Smith PL. A shift from central and mixed sleep apnea to obstructive sleep apnea resulting from low-flow oxygen. Am Rev Respir Dis. 1985;132:220 223.