Go With the Flow REGULATORY LANDSCAPE. Mark Copley at Copley Scientific

Similar documents
Caption: The equipment required for testing Fluticasone Propionate (FP) Inhalation Powder in line with a new product-specific monograph (USP36-NF31).

Testing Inhaled Generics

Optimising the application of in vitro test methods for the demonstration of bioequivalence in orally inhaled products

Assessing the role of breathing simulators in OIP testing

Characterizing the Performance of Metered Dose Inhalers with Add-On Devices: New Methods For Clinically Relevant Testing

Inhalation Product Research at FDA

Understanding cascade impaction and its importance for inhaler testing

INTRODUCTION. size and total nozzle area decrease with stage number. Volumetric air flow rate through

Understanding Regulatory Global Requirements for Nasal Drug Products. Julie D. Suman, Ph.D. April 8, 2016

Device Design Similarity

OPTIMISING ANALYTICAL STRATEGIES FOR THE DEMONSTRATION OF BIOEQUIVALENCE IN A GENERIC NEBULISER

Year in review. Vit Perlik Director of Regulatory Science and Clinical Development

Current Challenges and Opportunities in Demonstrating Bioequivalence

Draft Guidance on Fluticasone Propionate; Salmeterol Xinafoate. Fluticasone Propionate; Salmeterol Xinafoate. Powder/Inhalation

Drug/Device Combination Products: Bioequivalence

DISSOLUTION TESTING - Exploring the Link Between Particle Size & Dissolution Behavior for OINDPs

IPAC-RS/UF Orlando Inhalation Conference March 20, S.T. Horhota 1, C.B. Verkleij 2, P.J.G. Cornelissen 2, L. Bour 3, A. Sharma 3, M.

MDI. Recommended Equipment

Biopharmaceutics of Non-Orally Administrated Drugs

Equivalence Evaluation of Valved Holding Chambers (VHCs) with Albuterol Pressurized Metered Dose Inhaler (pmdi)

Adapting Pharmacopeial Testing for Pharmaceutical Equivalence Studies. Julie D. Suman, Ph.D. March 29, 2016

Understanding the links between drug delivery route and in vitro test methods Mark Copley, Sales Director, Copley Scientific

IMPROVING THE REALISM AND RELEVANCE OF MOUTH-THROAT MODELS FOR INHALED PRODUCT TESTING

Assessing Quality of Inhaled Products And Links to Efficacy and Safety

Lessons Learned from Approval of Generic Nasal Products

University of Groningen. Technology in practice Lexmond, Anne

VARIABILITY IN CASCADE IMPACTION: SOURCES, IMPACT AND STRATEGIES FOR REDUCTION

Patient. Device Clinician. Safety & efficacy

COMMENTS. Submitted by The International Pharmaceutical Aerosol Consortium

Considerations for Evaluation of Bioequivalence and Interchangeability of Orally Inhaled Products

COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP) GUIDELINE ON THE PHARMACEUTICAL QUALITY OF INHALATION AND NASAL PRODUCTS

Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U.S.A. Phone: Fax:

Metered Dose Inhaler Technology

Generic Inhaled Medications

Device Change Management for Inhaled Products. Loy Britto, Ph.D. GlaxoSmithKline ISAM Congress Munich 2015

Process Drift and it s Resolution in the Manufacture of Drug Products. MDI s and DPI s Metered Dose Inhalations and Dry Powder Inhalations

A NEW, ADVANCED HIGH- THROUGHPUT SYSTEM FOR AUTOMATED INHALER TESTING

COPLEY SCIENTIFIC. Quality Solutions for Inhaler Testing. metered-dose inhalers dry powder inhalers nebulisers nasal sprays

PREMIXES FOR MEDICATED FEEDING STUFFS FOR VETERINARY USE. Praeadmixta ad alimenta medicata ad usum veterinarium. Effervescent powders

Implications of the new CHMP Guideline on the Pharmaceutical Quality of Inhalation and Nasal Products

COPLEY SCIENTIFIC. Quality Solutions for Inhaler Testing Edition. metered-dose inhalers dry powder inhalers nebulisers nasal sprays

Qualifying Container Closure Systems for OINDP: Current & Future Regulatory Expectations. Julie D. Suman, Ph.D. November 14, 2014

REDUCING VARIABILITY IN TEST RESULTS FOR OINDPS WITH AUTOMATED ACTUATION

EPAG Perspective - Regulatory Advances Related to Nasal Spray Pumps. Dr G.Williams Nasal Drug Delivery Management Forum London, 15 Apr 2010

TRAINING DEVICE OPPORTUNITIES AND SOLUTIONS FOR A CHANGING RESPIRATORY MARKET

Misty Max 10 nebulizer

AEROSOL THERAPY: THE PRACTICALITIES

EPAG Sponsored Workshop on Abbreviated Impactor Measurement (AIM) and Efficient Data Analysis (EDA) Concepts in Inhaler Testing. Overview of AIM EDA

Dry Powder Inhaler. Developing an Efficient. 3M Conix DPI. White Paper / Spring Proven Solutions that Enable Your Success

Lawrence X. Yu, Ph.D. Director (acting) Office of Pharmaceutical Science Food and Drug Administration

Everything for Inhalation

COMPARISON OF THE RESPIRABLE FRACTION FROM THREE DIFERENT DPI DEVICES

SELECTING A DOSAGE FORM FOR DRUG DELIVERY TO THE LUNGS. Dr. Jay T. Holt, Ph.D., Sr. Director, Inhalation & Analytical

Meeting the Quality Challenge for Orally Inhaled Drug Products. Review Impact of Emerging EMA/MHRA Guidelines and Standards

General Chapter/Section: <232> Elemental Impurities - Limits Expert Committee(s): General Chapters Chemical Analysis No.

COMMITTEE ON MEDICINAL PRODUCTS FOR HUMAN USE (CHMP) DRAFT

Metered Dose Inhalers (MDIs) In Vitro Measures to Confirm Patient Perceptions: HFA vs. CFC

International Pharmaceutical Aerosol Consortium on Regulation and Science

What Do Cascade Impaction Measurements Tell Us: In Vitro Aspects. Context of Presentation

Research Article. *Corresponding author Mahesh M.Giri

SELECTING A DOSAGE FORM FOR DRUG DELIVERY TO THE LUNGS

EVALUATION AND RECOMMENDATION OF PHARMACOPOEIAL TEXTS FOR USE IN THE ICH REGIONS ON DISINTEGRATION TEST GENERAL CHAPTER Q4B ANNEX 5(R1)

Public Assessment Report Scientific discussion. Salmeterol/Fluticasone Sandoz (salmeterol xinafoate, fluticasone propionate) SE/H/1323/03/DC

905 UNIFORMITY OF DOSAGE UNITS

Completion of the development of a formulation: Requirements for compliance check vs. requirements for Marketing Authorisation

Public Assessment Report Scientific discussion. Flumetor (salmeterol xinafoate/fluticasone propionate) SE/H/1068/01-02/DC

Public Assessment Report. Scientific discussion. Elisox 50 microgram/actuation, nasal spray, suspension. (mometasone furoate) NL/H/2672/001/DC

Q&A for submission of applications for prequalification of Zinc Sulfate tablets and Zinc Sulfate oral liquid (solution)

National Transition Strategy to Replace CFC-based. MDIs with in the Commonwealth of Independent States. Paul Krajnik UNIDO, Montreal Protocol Branch

in the ICH Regions Table of Content Annexes to Guideline and 3. Why is Q4B necessary? Q4B Annexes? for Human Use

Guidance for Industry

University of Groningen. Optimisation of dry powder inhalation Boer, Anne Haaije de

Case Study 1: Pharmaceutical Development of EXUBERA

The Use of Physics-Based Modeling to Better Design Drug- Device Interface. Yoen-Ju Son, PhD Merck Research Laboratory, Summit, NJ

Bioequivalence Requirements: USA and EU

I. Subject: Medication Delivery by Metered Dose Inhaler (MDI)

The abbreviated impactor measurement concept

Ensuring the Quality of Some Drug-Device Combination Products - FDA Perspective

Interchangeable Drug Products - Additional Criteria

FDB FOOD AND DRUGS BOARD G H A N A GUIDELINES FOR CONDUCTING BIOEQUIVALENCE STUDIES

Bronchodilator Delivery and Nebuliser Trials in Adults

Patricia KP Burnell Inhalation Product Development

Delivery of Iloprost Inhalation Solution With the HaloLite, Prodose, and I-neb Adaptive Aerosol Delivery Systems: An In Vitro Study

Public Assessment Report. Scientific discussion. Ipratropiumbromide Sandoz 20 microgram per actuation, pressurised inhalation solution

INTEGRATED DESIGN SPACE TO DEVELOP BETTER DPI FORMULATIONS

Quality of Nasal and Inhalation Drug Products

Public Assessment Report. Scientific discussion. AirFluSal Aerosol 25/125 and 25/250 micrograms pressurised inhalation, suspension

Challenges in Nonclinical Development of Inhalation Drug Products

Inhalation Therapy. Inhalation Therapy

IVIVC in Pediatric OIPs

Respiratory. Martin Jetzer DDL27 Edinburgh December 2016

NEBULIZERS, METERED DOSE INHALERS, AND DRY POWDER INHALERS

Technology and Quality of Inhalation Drug Products

Formulation Considerations for Inhaled Products

Technical Monograph n 17, 2nd Edition. Guidelines for Specifying the Shelf Life of Plant Protection Products

Sub-components in Nicotine cessation products?

General Concepts in the European Pharmacopoeia. Anne-Sophie Bouin European Pharmacopoeia Department, EDQM, Council of Europe

PRACTICES OF COATING COLLECTION SURFACES OF CASCADE IMPACTORS: A SURVEY OF MEMBERS OF THE EUROPEAN PHARMACEUTICAL AEROSOL GROUP (EPAG)

Considerations in establishing bioequivalence of inhaled compounds

UPDATE ON THE GUIDELINE ON THE PHARMACEUTICAL QUALITY OF INHALATION AND NASAL PRODUCTS

Transcription:

Go With the Flow Image: Guzel Studio shutterstock.com Increasing global requirements for efficacious, inexpensive products to treat respiratory illnesses are driving the development of inhaled generics. In vitro methods represent the most efficient way of proving bioequivalence and can thereby aid a faster time to market Mark Copley at Copley Scientific Demonstrating bioequivalence (BE) to a reference labelled drug (RLD) enables safe interchangeable use within the clinical setting. In vitro techniques are a cost-efficient way of gathering evidence to support a claim of BE and can minimise, or even eliminate, the need for clinical testing, thereby reducing expense and time to market. Maximising the application of in vitro testing is therefore an important strategy for generic development. The following examines the application of in vitro techniques in inhaled generic product testing, focusing on tests specifically linked to regulatory guidance associated with demonstration of BE or indicated in the product-specific US Pharmacopeia (USP) monographs for popular generic targets. REGULATORY LANDSCAPE The most recent guidance from EMA relating particularly to inhaled generics was released in 2009 (1). It implies that BE can be shown through in vitro testing alone without pharmacokinetic and pharmacodynamic (PK/PD) studies providing a range of stringent criteria are met. Evidence must confirm the following (2): The active ingredient is the same, and in the same solid state, as in the RLD any differences in crystallinity or polymorphic form do not affect solubility Any changes to the excipient do not impact product safety or performance, aerosol particle behaviour and/or the behaviour of the patient Product handling is similar to the RLD The target delivered dose and the inhaled volume needed to deliver is the same as for the RLD (within +/- 15%) Resistance to air flow is the same as for the reference device (within +/-15%) 8

Inhalation Parenteral Technology Supplement Demonstrating BE through in vitro testing, therefore, relies on identifying tests that robustly characterise all these criteria. Currently the FDA does not offer equivalent general guidance for inhaled products; however, it has responded to the growing number of generic submissions with the release of productspecific guidance to support the design of BE studies and improve efficiency (3). In these guidances, in vitro testing forms part of a BE strategy alongside clinical trials (PK and/or PD studies). DEMONSTRATING IN VITRO BE EMA guidance highlights the fact that inhaled product efficacy derives from interaction between the formulation, device and patient. This determines the dose delivered and its particle size within the dispersed aerosol, which in turn influences deposition behaviour in the lungs. Both the USP and European Pharmacopoeia (Ph Eur) cover general chapters for inhaled product testing, detailing methods for delivered dose uniformity (DDU) and aerodynamic particle size distribution (APSD) measurement. However, product-specific USP monographs are now also available for certain generic targets, including the following: Fluticasone propionate inhalation aerosol (metered dose inhaler (MDI) delivery), 2013 (4) Fluticasone propionate inhalation powder (dry powder inhaler (DPI) delivery), 2013 (4) Salmeterol inhalation powder (DPI delivery), 2014 (5) Fluticasone propionate and salmeterol inhalation aerosol (proposed) (6) Fluticasone propionate and salmeterol inhalation powder (proposed) (6) Test equipment and methods defined in the general chapters mirror current best practice and are subject to ongoing refinement. Typically, they are used to meet EMA and FDA requirements. However, in generic development the need to demonstrate BE means Figure 1: Product-specific monographs glass sample collection apparatus for inhalation powders (left) and inhalation aerosols (right) researchers are often attempting to mimic performance characterised up to 20 years ago, before current test methods were in place. An alternative to the general chapter methods is to revert back to the tests applied during the first development. Differences between the methods outlined in the general chapters and product-specific monographs reflect this approach, referencing the RLD s heritage and the sometimes unique test methods utilised during its original development. Their use, whether in product development or for ongoing quality control, is not mandatory, but may reduce the burden of method validation and specification setting by minimising the risk that generated data are influenced by the equipment or test method used. DDU TESTING Delivered dose for MDIs and DPIs is usually measured by actuating the device into a dose uniformity sampling apparatus (DUSA). Following EMA guidance, DDU testing is able to verify that the generic delivers a comparable dose to the RLD s label claim. It can also provide supporting evidence that product performance is not adversely affected by excipient choice, and that the inhalation volume required for effective product use is the same as for the RLD. The conditions that are applied during testing vary depending on the type of product (7). All product-specific USP monographs reference glass sample collection apparatus for DDU testing, which is not included in the general chapters. Two designs are described one for inhalation aerosols, the other for inhalation powders (see Figure 1). The total air volume for inhalation powders testing is 2L, reflecting the lung capacity of an adult with a respiratory condition and consistent with the volume stated in the revised general USP chapter. However, both apparatus differ substantially from standard DUSAs in terms of their dimensional and operational specifications. To completely characterise the delivered dose, DDU testing is also used to verify and compare dose uniformity across the life of multipledose products. Compendia and regulatory methods recommend assaying doses from the beginning middle, in some cases and end of life, indicating the labelled number of doses for the product, and also specifying the number of devices 9

First stage nozzle(s) Seal Second stage nozzle(s) Aerosol particles by the flow rate of air entering the impactor during testing, which must be constant. Nebulisers are examined at a constant flow of 15L/min, which is deemed representative of the midtidal flow rate of a typical adult user, rather than under tidal (variable) flow conditions for other orally inhaled products, the flow rates applied are broadly the same as in DDU testing (unless add-on devices, such as spacers, are used). Intervening stages Last stage nozzle(s) Filter Vacuum Figure 2: Multistage cascade impactors size fractionate a dose on the basis of particle inertia, by progressively accelerating particles through a number of stages containing single or multiple nozzles and collecting them on a collection surface for subsequent chemical analysis Source: Adapted from USP <601> When comparing cascade impaction data to demonstrate BE, EMA guidance recommends stage-bystage assessment or comparison of a minimum of four groupings defined on the basis of inferred deposition site within the lung. Such groupings may include fine particle dose the dose in the one-to-five micron range considered optimal for pulmonary deposition but must span the full particle size range covered by the cascade impactor. Additional requirements include the need to test three batches of both the RLD and the generic, with maximum allowable differences calculated to form the basis of a decision justifying BE (8). The variability associated with cascade impaction (especially on stages carrying little drug mass) makes such comparisons arguably the most demanding step in demonstrating in vitro BE. Taking steps to improve the accuracy and precision of the technique can, therefore, be extremely helpful (7). that should be examined. Testing at a range of flow rates (commonly 30, 60 and 90L/min) may also be required to reflect the traits of the intended patient population. In addition, product-specific FDA guidance calls for population bioequivalance (PBE) analysis of measured dose uniformity data, on a single-actuation basis. MULTISTAGE CASCADE IMPACTION The preferred technique for measuring the APSD of all inhaled products is multistage cascade impaction, to infer and compare likely in vivo deposition behaviour. Cascade impaction, while not directly simulating the lung, can be used in demonstrating BE to investigate the likelihood of similar in vivo deposition properties. The size of a multistage cascade impactor fractionates a delivered dose on the basis of particle inertia, thus producing a series of samples for subsequent analysis (see Figure 2) (7). Their performance is determined FDA suggestions for the examination of in vitro BE are detailed in the productspecific guidance and are typically based on PBE analysis of impactor sized mass, the provision of individual stage masses and comparison of specific metrics derived from the APSD. PRODUCT-SPECIFIC USP MONOGRAPH These mention a modified induction port for cascade impactor testing for inhalation powders and aerosols, manufactured from aluminium or 316 stainless steels to match the 10

Andersen Cascade Impactor (ACI) specified. It has an inlet geometry similar to the glass twin impinger (GTI), reflecting practice at the time when these products were developed. GTI mouthpiece adapters can be used to connect the induction port with the device, while an O-ring-less tapered exit enables interfacing with the ACI via modified versions of its pre-separator and inlet cone, for inhalation powders and inhalation aerosols respectively. The introduction of ACI versions designed for testing at 60 and 90L/min post-date the development of the RLDs covered by the productspecific monographs. These specify use of the original 28.3L/min version of the ACI (stages 0 to 7, plus filter stage) with a test flow rate of 60L/min for inhalation powders. The total air volume for APSD measurement of inhalation powders is 3L, larger than is applied during DDU testing presumably in order to achieve adequate volume changes in the ACI. ATTRIBUTES INFLUENCING PATIENT BEHAVIOUR AND DRUG DELIVERY Additional product attributes that can influence patient behaviour and the efficiency of drug delivery are the cold Freon effect and the resistance of a DPI device. The cold Freon effect is the inadvertent response including coughing and exhalation to the chilling sensation at the back of the throat following actuation of a propellant-driven MDI. Among the commercial instruments that are used to measure the cold Freon effect is the Plume Temperature Tester Model PTT 1000, which measures temperature as a function of distance from the mouthpiece to produce a temperature profile for the plume. Along with measurements of the impaction force of the plume gathered with an instrument such as the Spray Force Tester Model SFT 1000, these data fully quantify the cold Freon effect, while simultaneously helping to substantiate therapeutic similarity. The flow resistance of a DPI device may also directly impact the inhalation manoeuvre of a patient. A device with a low resistance results in a higher flow rate of air passing through the device than one with high resistance, based on the same inspiratory effort. Device resistance can therefore affect aerosolisation performance, delivered dose and patient experience. The test setup used to determine the flow rate required for DDU and APSD measurements for DPIs, according to the USP and Ph Eur general chapters, is shown in Figure 3 (7). This can be manipulated to gauge the pressure drop across a device at a defined, fixed flow rate to learn and compare the internal resistance of an RLD and generic device. Measurements across a range of flow rates ensure complete characterisation of the device. ADVANCING IN VITRO TESTING General EMA and product-specific FDA guidance, as well as productspecific USP monographs, provide information to help generic developers substantiate therapeutic equivalence. They highlight the potential scope of required in vitro testing arising from the complexity of inhaled pharmaceuticals, the performance of which is subject to far greater variability than drug delivery via oral solid dosage. As correlations between in vitro measurements and in vivo behaviour are not yet secure, product replication remains challenging, broadening the scope of tests required to ensure efficacy and safety. Achieving better in vitro and in vivo relationships is an important goal for Figure 3: The test set-up used to determine the flow rate that generates a 4kPa pressure drop across a DPI, for DDU testing and APSD measurement, can be readily adapted to measure internal device resistance as a function of flow rate Critical flow controller Timer P 1 P 3 P 2 2-port/2-way solenoid valve Flow control value 12

the inhaled product community, and would strengthen BE studies (9). The use of breathing simulators producing more realistic breathing profiles during testing, for example, is increasingly common practice. Similarly, product innovations such as the Alberta Idealised Throat have been shown to improve conventional APSD testing instead of using the standard USP and Ph Eur induction port by better reflecting in vivo drug deposition behaviour. In vitro dissolution is also an area of increasing interest as developers endeavour to learn more about the fate of particles after pulmonary deposition. Demonstrating BE through in vitro testing is a cost-efficient goal for generic developers, but demands a rigorous and robust testing strategy. Both traditional and evolving test methods have a role to play in bringing new generics to market in a timely and efficient manner. References 1. EMA, Guideline on the requirements for clinical documentation for orally inhaled products including the requirements for demonstration of therapeutic equivalence between two inhaled products for use in the treatment of asthma and chronic obstructive pulmonary disease in adults and for use in the treatment of asthma in children and adolescents, January 2009 2. Hippchen C, Pharmacopoeial requirements for dry powder inhalation systems, presentation delivered at 2nd open forum on pharmaceutics and biopharmaceutics, Istanbul, Turkey, April 2012 3. FDA Guidance for Industry, Bioequivalence recommendations for specific products. Visit: www.fda. gov/downloads/drugs/guidance Compliance Regulatory Information/ Guidances/ucm072872.pdf 4. Second supplement to USP 36-NF31, New introductions: Fluticasone propionate inhalation powder and fluticasone propionate inhalation aerosol, December 2013 5. Second supplement to USP37-NF33, New introduction: Salmeterol inhalation powder, December 2014 6. USP Pharm Forum 41(1), Fluticasone propionate + salmeterol, inhalation aerosol and powder, February 2015 7. Copley M, Optimising cascade impactor testing for characterising orally inhaled and nasal spray drug products, Drug Delivery Technology, July/August 2010 8. Fuglsang A, Regulatory issues and challenges relating to pulmonary products, presentation delivered at 2nd open forum on pharmaceutics and biopharmaceutics, Istanbul, Turkey, April 2012 9. Copley M, Refining inhaled product testing, OnDrugDelivery, 2011 Mark Copley has been Technical Sales Manager and Product Specialist for Copley Scientific s range of inhaler testing equipment for eight years before becoming the company s Sales Director. Considered a leading authority in testing methods and systems for MDIs, DPIs, nebulisers and nasal sprays, he also sits on the editorial advisory panel of Inhalation magazine and is an invited member of the European Pharmaceutical Aerosol Group impactor subteam. Mark graduated from the University of Bath, UK in 2000 with a Master s degree in Aerospace Engineering. Email: sales@copleyscientific.co.uk The flow resistance of a DPI device may also directly impact the inhalation manoeuvre of a patient 13