Product Insert ProKera is approved by the US FDA (510K Approval) as a class II medical device.

Similar documents
Cryopreserved Human Hepatocytes (Cat # HP-F)

Human CD4+T Cell Care Manual

Instructions for Use. Wright Medical Technology 1023 Cherry Road Memphis, TN USA

Human Umbilical Cord Blood CD34 + /133+ Progenitor Cell Care Manual

I.C.E. Embryo Vitrification Kit

NEPHROCHECK Calibration Verification Kit Package Insert

READ BEFORE USING. Contents:

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

Safety Data Sheet Product Name: Heparin / PF4 Serum Panel - For In Vitro Diagnostic Use Only

QUICK REFERENCE INSTRUCTIONS. THYROCHEK TSH Cassette

T-PLIF Spacer. An allograft spacer for transforaminal posterior lumbar interbody fusion.

Monitoring the Health of Transplanted Organs DONOR GENOTYPING MANUAL

Human Umbilical Vein Endothelial Cell Manual

NEPHROCHECK Liquid Control Kit Package Insert

Human Mammary Luminal Epithelial Cells. Manual

HBeAg and HBeAg Ab ELISA Kit

Product Training & Certification

15. Procuring, processing and transporting gametes and

Fecal H. pylori Antigen Rapid Test (Strip)

Hepatitis C Virus (HCV) Antibody Test

Product Size Catalog Number. 500,000 proliferating cells. cryopreserved cells that have been thawed and cultured for three days at PromoCell.

Helicobacter pylori Antigen Test

PHOTOREFRACTIVE KERATECTOMY (PRK) PATIENT INFORMATION BOOKLET

SOP 17 BLOOD BANK. 3. Overall Responsibility: Blood Bank In-Change/Pathologist.

Living Donor Kerato-Limbal Stem Cell Transplant

Product Size Catalog Number

Monitoring the Health of Transplanted Organs INSTRUCTION MANUAL

TRANSFUSION ASSOCIATED DISEASE, RECALL, OR COMPLICATION INVESTIGATION POLICY I. FATALITIES AND COMPLICATIONS ASSOCIATED WITH TRANSFUSION:

Thawing. 10,000-15,000 cells per cm² 10,000-15,000 cells per cm² C ,000-15,000 cells per cm². Product Size Catalog Number

PRESCRIBING INFORMATION

Version No.: 5.0 TITLE: SDS FOR FECAL OCCULT BLOOD TEST KIT T1-CK SERIES Page 1 of 5

Follicle Dermal Papilla Cells

Chlamydia trachomatis (CHLa)Test Kit

NEPHROCHECK Liquid Control Kit Package Insert

A Guide to Administering

Material Safety Data Sheet

An Injector s Guide to OZURDEX (dexamethasone intravitreal implant) 0.7 mg

For use only with INSTRUCTIONS FOR USE

Lilly. Disposable Insulin Delivery Device User Manual

Malaria Pf/pan antigen Rapid Test

Human Keratinocyte Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

DETERMINE SPECIMEN REQUIREMENTS HIV-1/2 Ag/Ab Combo TESTING PROCEDURE

CORNEAL CONDITIONS CORNEAL TRANSPLANTATION

EYE CARE PROTOCOL FOR PATIENTS IN ITU

Medical Affairs Policy

Strep-a-Test Twister Test

2009 Eye Banking Statistical Report Eye Bank Association of America th Street, N.W. Suite 1010 Washington, DC Phone (202) Fax

ZADITEN Eye Drops 1.0%

Dry Eye Assessment and Management Study ELIGIBILITY OCULAR EVALUATION FORM

THE WOUND SOLUTION. (Freeze dried Acellular Dermal Matrix) (Cryopreserved Acellular Dermal Matrix)

Glaucoma Drainage Tube Surgery

Endothelial Cells (Large Vessels)

POSTERIOR LUMBAR FUSION SURGICAL TECHNIQUE USING A BONE VOID FILLER. Magnifuse. Bone Graft

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

AVIAN INFLUENZA COMMODITIES TRAINING GUIDE MODULE 3 - SAMPLING, RAPID TESTING AND PACKAGING PARTICIPANT HANDOUTS

TB LAM Ag Lateral Flow Assay Standard Operating Procedure

Hepatitis B surface antigen Ab ELISA Kit

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

PRECISION PROGRAM. Injection Technique Quick-Reference Guide. Companion booklet for the Video Guide to Injection Technique

Follicle Dermal Papilla Cell

Stevens Johnson Syndrome Foundation OnLine Newsletter

Rapid-VIDITEST C. difficile Ag (GDH) Card/Blister

Hepatitis A virus IgM ELISA Kit

Treponema Pallidum (TP) Antibody Test

Precision Focus...From Every Angle. BEFORE & AFTER PRK SURGERY Patient Instruction Booklet.

INDICATIONS ACULAR 0,5 % is indicated for the relief of inflammation following ocular surgery.

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

CIRCULAR OF INFORMATION PASTEURIZED HUMAN MILK

Alamo Tissue Service

Instructions For Use PRALUENT (PRAHL-u-ent) (alirocumab) Injection, for Subcutaneous Injection Single-Dose Pre-Filled Syringe (75 mg/ml)

Autologous plasma eye drops. Patient information

HIV-1/2 Ab ELISA Kit. Catalog Number KA assays Version: 12. Intended for research use only.

LASER REFRACTIVE CENTER INFORMED CONSENT DOCUMENT PERIPHERAL CORNEAL RELAXING INCISION (PCRI)

CDIA TM Rubella IgG/IgM Rapid Test Kit

Maryland Vaccines for Children Program VACCINE MANAGEMENT PLAN

READ THIS FOR SAFE AND EFFECTIVE USE OF YOUR MEDICINE PATIENT MEDICATION INFORMATION. XIIDRA TM* Lifitegrast Ophthalmic Solution 5%

Device Preparation (all steps to be performed per standard interventional technique)

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

INSTALLATION MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

UNIVERSITY OF WASHINGTON MEDICAL CENTER Men s Health Center and Male Fertility Laboratory Sperm & Testis Cryopreservation Program Patient NAME and ID

Epicel (cultured epidermal autografts) HDE# BH Patient Information

Precision Focus...From Every Angle. BEFORE & AFTER LASIK SURGERY Patient Instruction Booklet.

Human Influenza A (Swine Flu) Rapid test

ALLOGRAFT VESSELS FROM CADAVERIC DONORS: PRESERVATION, USE AND DISPOSAL

DIAGNOSTIC AUTOMATION, INC.

1060 Holland Dr., Suite A Boca Raton, FL Nationwide: (877) Local: (561) Fax: (561)

Organ Procurement and Transplantation Network

FREQUENTLY ASKED QUESTIONS. Frequently Asked Questions

Product Training & Certification

Integra Flowable Wound Matrix

SAMPLE PROCEDURE , 07/11

Custom Prosthetic Eyes

PRODUCT INFORMATION ALCAINE. Proparacaine Hydrochloride Sterile Ophthalmic Solution, USP. 5 mg/ml. Topical Anesthetic

CONSENT FOR PHOTOTHERAPEUTIC KERATECTOMY (PTK)

BONE VOID FILLERS CONTAINING DONATED HUMAN TISSUE The following languages are included in this packet:

INSTRUCTION FOR USE EIA-ANTI-HDV

Endothelial Cells (Microvascular)

CryoVein Femoral Vein. Other Vascular Allograft included (not pictured): CryoVein Saphenous Vein, Double Graft Pack. (non-cannulated) Pulmonary Human

DRY EYE and MGD. Contact Central Maryland Eye Associates Today.

Transcription:

Product Insert ProKera is approved by the US FDA (510K Approval) as a class II medical device. Effective Date: 2/23/2005 Version 1

ProKera is a corneal-epithelial device consisting of an ophthalmic conformer that incorporates amniotic membrane (AmnioGraft ). ProKera is for physician use only and is not intended to be used by patients without a doctor s recommendation. ProKera is intended for use in eyes in which ocular surface cells have been damaged, or underlying stroma is inflamed and scarred. It can be used as a graft for ocular surface reconstruction procedures including the following: Corneal Diseases with Erosion Corneal Diseases with Superficial and Deep Ulceration In Conjunction with Corneal Transplantation Neurotrophic Corneal Diseases Acute Corneal or Conjuctiva Burns or Stevens Johnson Syndrome After Fornix or Socket Reconstruction Severe Corneal Inflammation ProKera has been assembled so that the stromal side, the sticky side, will be in contact with the recipient s ocular surface. ProKera is specially preserved in the frozen state and the natural biological/physiological properties of the membrane remain. Therefore, it can promote healing, prevent scarring, minimize pain, diminish the formation of new blood vessels and reduce inflammation on the ocular surface. ProKera is preserved in a validated and patented storage medium made of Dulbecco s Modified Eagle Medium and Glycerol (1:1) containing Ciprofloxacin and Amphotericin B. No preservatives or additives have been added. The device has been stored at 80 C prior to distribution. It is imperative that the graft device is stored properly until use. Storage Information Usage after Storage Receipt of Temperature: Device Few hours Frozen after package arrival Within 1 week of receipt (with no freezer) Within 3 months of receipt Long term storage Acceptable Storage Location: Styrofoam shipping container 4 C (39.2 F) Standard Home Refrigerator -20 C (-4 F) -80 C (-112 F) Standard Home Freezer Bone Freezer Storage Time: Until Dry-Ice expiration date on package 1 week (media in liquid state) 3 months (media in liquid state) Until expiration date on package (media frozen solid) Page 2 of 8

Pre-Use Instructions Contact Bio-Tissue immediately for further instructions if the packaging appears to be damaged in any way, if the package contains no dry ice at the time of arrival, or if the package is expired at the time of arrival If packaging damage is noted, do not sterilize or re-sterilize the product Once outer foil pouch is opened, ProKera must be used immediately or discarded. If it is discarded, a record of device disposal shall be recorded on the Donor & Recipient Information Form and sent back to Bio-Tissue. ProKera may only be used by those physicians or facilities that are qualified to accept tissues and have accepted responsibility for proper handling and tissue tracking. Bio-Tissue assumes no responsibility for the clinical use of ProKera. Although all screening and testing results were satisfactory for this donor, this membrane may transmit infectious agents. Microbiological testing on the membrane was acceptable. Detailed information on this device is disclosed on The Donor & Recipient Information Form and on the Certificate of Quality. ProKera Sizing Information If patient cannot close the eyelid, do not use ProKera. Use a 15 mm ProKera with Small to Medium-Sized Eyes: A small eye (picture in actual size) Use a Size 16 mm ProKera with Large Eyes: A large eye (picture in actual size) Page 3 of 8

Physician Instructions I. General Materials Needed: Materials Provided: 1. Sterile lid speculum 5. Medi-PAK Kit with sterile 2. Sterile gloves scissors and forceps 3. Anesthetic drops 6. Bio-Tissue Donor Recipient 4. Antibiotic drops Information (DRI) form General Precautions: There are several sizes of ProKera available. A patient s Interpalpebral width should be measured and the correct ProKera size should be determined using the provided sizing chart (see page 3). Immediately prior to use, thaw at room temperature for 5-10 minutes (do not use a microwave or water bath) Do not trim excess membrane Prior to use, ensure that: o There are no tears or rips in the package o Patient can close the eyelid (no lagophthalmos) o Patient is not wearing contact lenses o There is no patient history of drug reactions to Ciprofloxacin or Amphotericin B Do not autoclave before use Do not re-use for single use only Opening Package: 1. Open outer foil package by tearing across from the tab 2. Use sterile scissors to cut the inner package with enough space to remove the ProKera Tab Page 4 of 8

II. Pre-Insertion Handle ProKera using sterile techniques Note that the ProKera membrane is very slippery use sterile forceps or fingers to grasp only at the rim of the ProKera Handle the membrane with care to avoid tearing and touching the membrane in the center use blunt instruments only III. Insertion Use a lid speculum to insert the ProKera beneath it. (pictures 1 and 2) This is accomplished by lifting the lid speculum so that the ProKera can rest beneath it. Administer anesthetic drops. (picture 3) Provide prophylactic antibiotic drops. After insertion (pictures 4 and 5), ProKera can remain in the eye until the ocular surface has healed or the membrane has dissolved (up to 8 weeks) during which time the healing can be assessed by fluorescein staining and eye pressure measured by Tonopen. Provide the patient with the ProKera Patient Instructions (see page 7). 1 2 Page 5 of 8

3 4 5 IV. Temporary Storage If ProKera needs to be temporarily removed (for example, to check patient healing progress) it can be stored in sterile PBS until reinsertion. V. Removal Upon completion of treatment, the physician should remove the ProKera conformer with a sterile forcep, with or without the help of a lid speculum. VI. Post-Use Instructions After the insertion, the Donor & Recipient Information Form is to be filled out and returned to Bio-Tissue immediately. Any adverse event potentially attributable to the membrane must be reported promptly by the end-user physician to Bio-Tissue by completing the Adverse Event Form. If the end-user needs any additional information about the donor or processing procedures, return policy or other questions, please contact Bio-Tissue at (305) 412 4430 or 1-888-296-8858. Page 6 of 8

VII. Patient Instructions Remove the attachment below and give it to patient. ProKera Patient Instructions Handout Do not wear contact lenses during ProKera use. Avoid rubbing, strong blinking or moving ProKera around with your fingers. Do not swim or soak face with water without appropriate protective eyewear. Shower only when the eye is tightly closed. Use artificial tears or other eye drops 3-4 times daily, especially if there is a concern of dry eye or exposure. Do not drive, operate heavy machinery or perform functions that require unobstructed vision or good depth perception. Consult your physician right away if discomfort is experienced or if any other problems are encountered. Page 7 of 8

Certificate of Quality Product Name: ProKera Good Manufacturing Practice (GMP) This product was manufactured and assembled in facilities that meet FDA Medical Device GMP Standards and FDA Good Tissue Practices (GTP) Standards. ISO 9000: This product s ophthalmic conformer was manufactured in a facility whose Quality Management System is approved by an accredited registering body to the appropriate ISO 9000 Quality Systems Standard. Microbiological Testing: Microbiology testing by an independent laboratory showed that random samples of this product yielded no growth of anaerobic, aerobic or fungal organisms. Donor Screening & Infectious Disease Testing: AmnioGraft has been recovered aseptically from a donated placental membrane through elective Caesarian Section delivery. The donor was screened for infectious, malignant, neurological, and autoimmune diseases and other exposures or habits and determined to be suitable to donate membrane for human transplantation. The donor of this product was tested at the time of delivery and found to be non-reactive for HIV-1 & HIV-2 (antibodies), Hepatitis B surface antigen (HBsAg), Hepatitis B core antibody (HBcAb), Hepatitis C antibody (HCV), HTLV 1 & 2 antibodies, and syphilis (RPR) using test kits licensed by the FDA. If you have further questions regarding ProKera, please e-mail Bio-Tissue at Info@BioTissue.com or call (305) 412-4430. If you have specific technical questions regarding ProKera, please e-mail Dr. Scheffer Tseng at stseng@ocularsurface.com or call (305) 274-1299. Bio-Tissue Address: 7000 SW 97 th Avenue, Suite 211, Miami, FL 33173 Phone: (305) 412-4430 Toll Free Customer Service: (888) 296-8858 FAX: (305) 412-4429 E-mail: Info@BioTissue.com Web Site: www.biotissue.com Page 8 of 8