Original Article INTRODUCTION

Similar documents
Performance of Half-dose Chest Computed Tomography in Lung Malignancy Using an Iterative Reconstruction Technique

Effect of iterative reconstruction on image quality of low-dose chest computed tomography

Ultralow Dose Chest CT with MBIR

How to Develop CT Protocols for Children

Original Article Thoracic Imaging

A more accurate method to estimate patient dose during body CT examinations with tube current modulation

Pediatric chest HRCT using the idose 4 Hybrid Iterative Reconstruction Algorithm: Which idose level to choose?

Translating Protocols Across Patient Size: Babies to Bariatric

354 Korean J Radiol 9(4), August 2008

Improved image quality of low-dose thoracic CT examinations with a new postprocessing software*

Application of CARE kv and SAFIRE in Contrast-Enhanced CT Examination on Thorax

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

Original Article Thoracic Imaging

Dual Energy CT Aortography: Can We Reduce Iodine Dose??

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

Min Hur, Eun-Hee Kim, In-Kyung Song, Ji-Hyun Lee, Hee-Soo Kim, and Jin Tae Kim INTRODUCTION. Clinical Research

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

X-Ray & CT Physics / Clinical CT

To Shield or Not to Shield? Lincoln L. Berland, M.D.

Purpose. Methods and Materials

Original Article Thoracic Imaging. Hyun Jung Yoon, MD 1, 2, Myung Jin Chung, MD 1, Hye Sun Hwang, MD 1, Jung Won Moon, MD 3, Kyung Soo Lee, MD 1

An Introduction to Dual Energy Computed Tomography

Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)

CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction

At present, CT of the brain is the imaging technique of choice

Low Dose Era in Cardiac CT

Automatic Patient Centering for MDCT: Effect on Radiation Dose

Correlation of Patient Weight and Cross-Sectional Dimensions with Subjective Image Quality at Standard Dose Abdominal CT

Estimation of Stellate Ganglion Block Injection Point Using the Cricoid Cartilage as Landmark Through X-ray Review

CT Low Dose Lung Cancer Screening. Part I. Journey to LDCT LCS Program

Dual-Energy CT: The Technological Approaches

Coronary Calcium Screening Using Low-Dose Lung Cancer Screening: Effectiveness of MDCT with Retrospective Reconstruction

Comparison of CT findings between MDR-TB and XDR-TB

With increasing use of computed tomography (CT) in modern medicine, concerns have arisen regarding increasing radiation dose to the community from med

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters

Medical Physics and Informatics Original Research

Spectral CT imaging as a new quantitative tool? Assessment of perfusion defects of pulmonary parenchyma in patients with lung cancer

Optimizing radiation dose by varying age at pediatric temporal bone CT

Measurement error of spiral CT Volumetry:

Pulmonary Embolism. Thoracic radiologist Helena Lauri

Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT 1

CT angiography of pulmonary arteries to detect pulmonary embolism with low kv settings

Uozu city/jp, Minatoku, Tokyo/JP Bones, Extremities, CT, Surgery, Physics, Artifacts, Image verification /ecr2014/C-0462

Dual-Energy 101: Principles, Methods and Dose

Low-dose CT Lung Cancer Screening Guidelines for Pulmonary Nodules Management Version 2

Comparison of CT findings of between MDR-TB and XDR-TB: A propensity score matching study

Trends of CT Use in the Adult Emergency Department in a Tertiary Academic Hospital of Korea during

Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

Identification of Missed Pulmonary Nodules on Low Dose CT Lung Cancer Screening Studies Using an Automatic Detection System

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Case Report Three-Dimensional Dual-Energy Computed Tomography for Enhancing Stone/Stent Contrasting and Stone Visualization in Urolithiasis

Computer-Aided Detection in Screening CT for

A study on CT pulmonary angiography at low kv and low-concentration contrast medium using iterative reconstruction.

Low-Dose CT: Clinical Studies & the Radiologist Perspective

A VIRTUAL TRAINING SYSTEM FOR CHEST RADIOGRAM INTERPRETATIONS USING ANATOMICAL HUMAN STRUCTURES IN HIGH-RESOLUTION CT IMAGES

Prevalence of Sarcopenia Adjusted Body Mass Index in the Korean Woman Based on the Korean National Health and Nutritional Examination Surveys

Radiation dose of cardiac CT what is the evidence?

Gender differences in CT calcium scoring: A phantom study

Pediatric High-Resolution Chest CT

Tests Your Pulmonologist Might Order. Center For Cardiac Fitness Pulmonary Rehab Program The Miriam Hospital

Diagnostic benefits of ultrasound-guided. CNB) versus mammograph-guided biopsy for suspicious microcalcifications. without definite breast mass

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

Ask EuroSafe Imaging. Tips & Tricks. Paediatric Imaging Working Group. Shielding in pediatric CT

Managing Radiation Risk in Pediatric CT Imaging

HRCT in CHILDREN. strengths and weaknesses in practice: Dr Catherine Owens BSc MBBS MRCP FRCR. Great Ormond Street Hospital for Children NHS Trust

Cardiac CT Lowering the Dose Dramatically

Low-dose CT coronary angiography: Role of adaptive statistical iterative reconstruction (ASIR)

How do the Parameters affect Image Quality and Dose for Abdominal CT? Image Review

E. Senéterre*, F. Paganin**, J.M. Bruel*, F.B. Michel**, J. Bousquet**

Studies in both the United States and Europe have revealed that computed tomographic (CT) examinations account for only up to 15% of all imaging exami

Vascular and Interventional Radiology Original Research

Original Article Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination

Outcomes in the NLST. Health system infrastructure needs to implement screening

Metal Artifact Reduction by Dual Energy CT

Any imbalance in the production or resorption of CSF results

National Cancer Institute

Dual Energy CT of the Heart: Perfusion and Beyond

Dose reduction in oncological staging multidetector CT: effect of iterative reconstruction

Role of CT imaging to evaluate solitary pulmonary nodule with extrapulmonary neoplasms

Sectional Anatomy Quiz II

Functional Chest MRI in Children Hyun Woo Goo

Lung structure recognition: a further study of thoracic organ recognitions based on CT images

PMP. Original Article. Introduction. Hee Jung Kim, Sung Yong Park, Young Hee Park, Ah Ram Chang

Coexistence of parathyroid adenoma and papillary thyroid carcinoma. Yong Sang Lee, Kee-Hyun Nam, Woong Youn Chung, Hang-Seok Chang, Cheong Soo Park

Fused monochromatic imaging acquired by single source dual energy CT in hepatocellular carcinoma during arterial phase: an initial experience

Yang Hou 1, Jiahe Zheng 1, Yuke Wang 1, Mei Yu 1, Mani Vembar 2, Qiyong Guo 1 * Abstract. Introduction

Comparison of High-resolution CT Findings between Miliary Metastases and Miliary Tuberculosis 1

Prediction of Cancer Incidence and Mortality in Korea, 2013

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology

BODY TOMOSYNTHESIS A. INTRODUCTION/CURRENT PRACTICE. Conventional radiography (X-ray)

COMPUTED TOMOGRAPHY COURSE

Radiation Exposure in Pregnancy. John R. Mayo UNIVERSITY OF BRITISH COLUMBIA

Small Pulmonary Nodules: Our Preliminary Experience in Volumetric Analysis of Doubling Times

Dose to Radiosensitive Organs During Routine Chest CT: Effects of Tube Current Modulation

The radiation dose in retrospective

THE TUFFEST STUFF CT REGISTRY REVIEW Live Lecture Seminar SATURDAY CURRICULUM

Prediction of Cancer Incidence and Mortality in Korea, 2018

Transcription:

Original Article http://dx.doi.org/10.3348/kjr.2012.13.6.720 pissn 1229-6929 eissn 2005-8330 Korean J Radiol 2012;13(6):720-727 Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part II: Assessment of Radiologists Preferences Using Dual Source CT Hye Jeon Hwang, MD 1, Joon Beom Seo, MD 1, Jin Seong Lee, MD 1, Jae-Woo Song, MD 1, Song Soo Kim, MD 2, Hyun Joo Lee, MD 1, Chae Hun Lim, MD 1,3 1 Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 138-736, Korea; 2 Department of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon 301-721, Korea; 3 Department of Radiology, Seoul St. Mary s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701, Korea Objective: To evaluate the impact of radiation dose and reconstruction algorithms on radiologists preferences, and whether an iterative reconstruction in image space (IRIS) can be used for dose reduction in chest CT. Materials and Methods: Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kvp and same reference mas (50 mas for SDCT and 25 mas for LDCT) employed to both tubes by modifying the dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from one tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Ten H-IRIS/F-IRIS, 10 H-FBP/H-IRIS, 40 F-FBP/F-IRIS and 40 F-FBP/H-IRIS pairs of each SDCT and LDCT were randomized. The preference for clinical usage was determined by two radiologists with a 5-point-scale system for the followings: noise, contrast, and sharpness of mediastinum and lung. Results: Radiologists preferred IRIS over FBP images in the same radiation dose for the evaluation of the lungs in both SDCT (p = 0.035) and LDCT (p < 0.001). When comparing between H-IRIS and F-IRIS, decreased radiation resulted in decreased preference. Observers preferred H-IRIS over F-FBP for the lungs in both SDCT and LDCT, even with reduced radiation dose by half in IRIS image (p < 0.05). Conclusion: Radiologists preference may be influenced by both radiation dose and reconstruction algorithm. According to our preliminary results, dose reduction at 50% with IRIS may be feasible for lung parenchymal evaluation. Index terms: Iterative reconstruction in image space; Chest CT; Radiation dose reduction; Preference Received December 15, 2011; accepted after revision May 25, 2012. This study was supported by a grant of the Korean Health Technology R&D Project, Ministry of Health & Welfare, Republic of Korea (A111599). Corresponding author: Joon Beom Seo, MD, Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43- gil, Songpa-gu, Seoul 138-736, Korea Tel: (822) 3010-4400 Fax: (822) 476-4719 E-mail: seojb@amc.seoul.kr This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. INTRODUCTION As the use of CT for diagnosis and intervention increases, radiologists, physicists, and CT scanner manufacturers are required to reduce the radiation exposure from CT (1-8). Radiation dose is directly proportional to the tube current at a fixed peak tube voltage, scanning time, and slice width. However, the image noise is inversely proportional to the square root of the mas using filtered back projection (FBP) method, which is the currently used CT image reconstruction technique. Thus, increase in the image noise is inevitable when we use lower tube current mode (9). Although several studies have evaluated the use of low- to ultra-low-dose 720 Korean J Radiol 13(6), Nov/Dec 2012 kjronline.org

Iterative Reconstruction in DECT of Chest and Radiologists Preference chest CT (10-14), using a lower milliampere-second setting has some potential disadvantages, including high rates of artifacts and false-negative results (12, 14). Image reconstruction in image space (IRIS) is a new CT reconstruction technique using an iterative reconstruction technique and was recently introduced to CTs. In our previous study, we evaluated whether the IRIS technique improves the image quality (IQ) at a standard dose CT (SDCT) and low dose CT (LDCT), and whether the IRIS can reduce the radiation dose by half. Our results indicated that IRIS generally improves the image quality of a chest CT, but that, even with IRIS, decreased radiation dose by half results in a decrease of the IQ. In that study, we assessed the subjective IQ scores for each image and compared the IQ scores. For clinical application, however, it may be more important to determine the preference of expert radiologists directly from a side-by-side comparison. We, therefore, assessed the effect of the radiation dose and reconstruction algorithms on the radiologists preferences. MATERIALS AND METHODS Patients This prospective study was approved by our institutional review board. Informed consent was obtained from all participating patients. From March to April 2010, 50 patients (30 men, 20 women; mean age, 56.4 ± 14.9 years; range, 18-79 years, mean BMI, 23.0 ± 3.0 kg/m 2 ) underwent SDCT and another 50 patients (31 men, 19 women; mean age, 57.2 ± 11.9 years; range, 27-76 years, BMI, 24.0 ± 3.0 kg/m 2 ) underwent LDCT. All patients were evaluated for the checkup or for known abnormalities. CT Examination and Reconstruction Detailed CT protocols have been described in our previous report (15). Both full-radiation dose data and half-radiation dose data, from one SDCT scan, were reconstructed using the standard FBP algorithm and the IRIS algorithm. Therefore, 4 CT image sets from one SDCT scan were obtained: 1) FBP images at full radiation dose (F-FBP), 2) IRIS images at full radiation dose (F-IRIS), 3) FBP images at half radiation dose (H-FBP), and 4) IRIS images at half radiation dose (H-IRIS). Finally, a total of 200 CT image sets from 50 SDCT scans, were prepared for review. In FBP images, the CT images were reconstructed in 5 mm thickness at 5 mm intervals with the B30f kernel for evaluation of mediastinal structures, and the CT images were reconstructed at 5 mm thickness at 5-mm intervals, and 1 mm thickness at 1 mm intervals with B70f kernel for the evaluation of the lung parenchyma. For IRIS, we used the I30f (5 mm thickness at 5 mm intervals) for the mediastinum and the I70f (5 mm thickness at 5 mm intervals and 1 mm thickness at 1 mm intervals, respectively) for the lung parenchyma. We also performed the image reconstruction in the same way for LDCT images, and we prepared 200 CT image sets of LDCT for review. Consecutive CT examinations were dicomized and sent to picture archiving and communication system (Petavision; Asan Medical Center, Seoul, Korea). For the evaluations of the mediastinum, the CT images with 5 mm slice thickness and B30f kernel or I30f were the preset at the window level of 35 H and window width of 350 H. For the evaluations of lung parenchyma, the appropriate CT images were preset at the lung window setting (window level of -700 H and a window width of 1500 H). The radiologists were asked not to change the preset window levels and widths, during the evaluation of IQ. Radiologists Preference and Data Analysis To evaluate the effect of radiation dose on the radiologists preference and for internal validation of these preferences, 10 F-IRIS/H-IRIS image pairs from both SDCT and LDCT were prepared. The effect of the reconstruction algorithm on the radiologists preferences was assessed, using 40 F-IRIS/F-FBP pairs and 10 H-IRIS/H-FBP pairs from both SDCT and LDCT, and the mixed effects of radiation dose and reconstruction algorithm on radiologists preferences were determined, using 40 F-FBP/H-IRIS pairs from both SDCT and LDCT. The 100 pairs of CT images retrospectively from both SDCT and LDCT were randomized and evaluated independently by two chest radiologists (reader 1 with 16 years of experience and reader 2 with 20 years of experience in thoracic imaging), who were blinded to the reconstruction methods and radiation doses. The radiologists, independently determined their preferences for the clinical usage with a 5-point-scale system (A/B, 1, strongly preferred A; 2, somewhat preferred A; 3, no preference; 4, somewhat preferred B; 5, strongly preferred B), based on the image noise, contrast, and anatomic region definition of mediastinal and lung structures. Preferences for mediastinal images were assessed on B30f and I30f/5 mm slice thickness images, and for lung parenchyma on B70f and I70f/5 mm and 1 mm slice thickness images. The two radiologists were asked to consider the same categories in kjronline.org Korean J Radiol 13(6), Nov/Dec 2012 721

Hwang et al. determining the image preference, as those of our previous study (Table 1) (15). Wilcoxon s signed rank tests were used to evaluate the statistical significance of radiologists preferences on F-IRIS/F-FBP and F-FBP/H-IRIS pairs, with p values < 0.05 considered as statistically significant. RESULTS When we compared the H-IRIS images and F-FBP images for the evaluation of the combined effects of radiation Table 1. Categories for Quality Assessment 1. Noise 2. Contrast 3. Sharp reproduction of major mediastinum Mediastinum structures (trachea, esophagus, SVC, heart, aorta, pulmonary artery, excluding motion artifact) Lung image (5 mm) Lung image (1 mm) Overall 4. Noise 5. Contrast 6. Central lung image sharpness, vessels, and bronchi 7. Peripheral lung image sharpness (vessels within 20 mm of pleural surface) 8. Noise 9. Contrast 10. Central lung image sharpness, vessels, and bronchi 11. Peripheral lung image sharpness (vessels within 20 mm of pleural surface) 12. Overall image quality Note. SVC = suerior vena cava dose and reconstruction algorithm, we found that both radiologists preferred the IRIS images, even though the radiation dose was reduced by half, over the FBP images with full radiation dose for the evaluation of the lung parenchyma and overall IQ in both SDCT and LDCT (p < 0.05 each, except for overall IQ in SDCT) (Table 2) (Figs. 1-3). The evaluation of the effects of the reconstruction method, by comparisons of F-FBP and F-IRIS pairs and of H-FBP and H-IRIS pairs, showed that the IRIS images were preferred for the evaluation of the lung and the overall IQ (p < 0.001 in full dose images; Tables 3, 4). In contrast, both radiologists preferred the FBP over the IRIS images for evaluation of the mediastinum in both SDCT (p = 0.035) and LDCT (p < 0.001) (Tables 2, 3) (Fig. 4). Both radiologists preferred CT images at higher radiation dose in all the assessed categories (Table 5). Figures 1, 2 and 3 illustrate the lung parenchyma in F-FBP, F-IRIS and H-IRIS images of the SDCT and LDCT. Figure 4 shows the mediastinal images in F-FBP, F-IRIS and H-IRIS of the SDCT. DISCUSSION We have evaluated the radiologists preferences for CT images, reconstructed with the FBP and IRIS algorithms for the clinical usage. In our previous study, we evaluated the subjective IQ scores on each assessment contents, such as noise, sharpness, and contrast on FBP and IRIS images, but we did not evaluate the radiologists overall preferences for clinical practice. The IRIS method uses a non-linear image processing algorithm, called regularization, Table 2. Effect of Both Radiation Dose and Reconstruction Method on Radiologists Preference A. Standard Dose Chest CT Comparison of F-FBP/H-IRIS P Mediastinum 1 10 68 1 0 0.006 Lung (5 mm) 1 3 46 27 3 < 0.001 Lung (1 mm) 1 8 45 24 2 0.006 Overall 0 7 56 16 1 0.064 B. Low Dose Chest CT Comparison of F-FBP/H-IRIS P Mediastinum 1 26 50 3 0 < 0.001 Lung (5 mm) 0 2 55 20 3 < 0.001 Lung (1 mm) 2 7 49 19 3 0.029 Overall 0 6 57 15 2 0.035 Note. Combined data from two observers. 1 = strongly preferred F-FBP image, 2 = somewhat preferred F-FBP image, 3 = no preference, 4 = somewhat preferred H-IRIS image, 5 = strongly preferred H-IRIS image. In Wilcoxon s rank sum test, p < 0.05 indicates significant difference. F-FBP = full dose image with filtered back projection, H-IRIS = half dose image with interative reconstruction in image space (IRIS, Siemens Healthcare, Erlangen, Germany) 722 Korean J Radiol 13(6), Nov/Dec 2012 kjronline.org

Iterative Reconstruction in DECT of Chest and Radiologists Preference not just simple noise reduction, which makes the image characteristics of IRIS unique and different from those of the FBP images. Therefore, even if the individual IQ scores of the assessed contents could be high in the IRIS images, radiologists preferences for clinical usage may be influenced by imaging characteristics and overall image quality, making it important to determine experts overall opinions about which the image is favored for the clinical practice by comparing the images, side-by-side. We found that both expert radiologists preferred the IRIS images even with the reduced radiation dose by half over the FBP image with full radiation dose for the evaluation of the lung parenchyma in both SDCT and LDCT. Our explanation is that the improved back ground noise reduction of the lung parenchyma and concurrently preserved the sharpness of the vessel and bronchial in the regularization step of the IRIS images may affect the preference of the radiologists. However, although we used the same imaging data, as in our previous study (15), in which we investigated whether the IRIS technique can reduce the radiation dose by half, using the radiologists subjective IQ scoring system, the results of these two studies differed from each other. In the previous study, the reduced radiation dose resulted in reduced IQ, even Table 3. Effect of Reconstruction Method on Radiologists Preference, Full Dose Image A. Standard Dose Chest CT Comparison of F-FBP/F-IRIS P Mediastinum 2 21 47 10 0 0.035 Lung (5 mm) 1 3 20 33 23 < 0.001 Lung (1 mm) 0 5 18 30 27 < 0.001 Overall 1 4 26 32 17 < 0.001 B. Low Dose Chest CT Comparison of F-FBP/F-IRIS P Mediastinum 2 37 36 5 0 < 0.001 Lung (5 mm) 1 5 19 30 25 < 0.001 Lung (1 mm) 1 4 21 26 28 < 0.001 Overall 1 4 28 38 9 < 0.001 Note. Combined data from two observers. 1 = strongly preferred F-FBP image, 2 = somewhat preferred F-FBP image, 3 = no preference, 4 = somewhat preferred F-IRIS image, 5 = strongly preferred F-IRIS image. In Wilcoxon s rank sum test, p < 0.05 indicates significant difference. F/FBP = full dose image with filtered back projection, F/IRIS = full dose image with iterative reconstruction in image space (IRIS, Siemens Healthcare, Erlangen, Germany) Table 4. Effect of Reconstruction Method on Radiologists Preference, Half Dose Image A. Standard Dose Chest CT Comparison of H-FBP/H-IRIS Mediastinum 0 3 12 4 1 Lung (5 mm) 0 0 1 9 10 Lung (1 mm) 0 0 1 5 14 Overall 0 6 1 6 7 B. Low Dose Chest CT Comparison of H-FBP/H-IRIS Mediastinum 0 4 14 2 0 Lung (5 mm) 0 1 2 12 5 Lung (1 mm) 0 2 1 6 11 Overall 0 4 2 8 6 Note. Combined data from two observers. 1 = strongly preferred H-FBP image, 2 = somewhat preferred H-FBP image, 3 = no preference, 4 = somewhat preferred H-IRIS image, 5 = strongly preferred H-IRIS image. H/FBP = half dose image with filtered back projection, H/IRIS = half dose image with iterative reconstruction in image space (IRIS, Siemens Healthcare, Erlangen, Germany) kjronline.org Korean J Radiol 13(6), Nov/Dec 2012 723

Hwang et al. Table 5. Effect of Radiation Dose on Radiologists Preference A. Standard Dose Chest CT Comparison of F-IRIS/H-IRIS Mediastinum 1 9 10 0 0 Lung (5 mm) 4 9 7 0 0 Lung (1 mm) 3 10 7 0 0 Overall 4 8 8 0 0 B. Low Dose Chest CT Comparison of F-IRIS/H-IRIS Mediastinum 0 7 11 2 0 Lung (5 mm) 3 10 7 0 0 Lung (1 mm) 5 9 6 0 0 Overall 2 11 7 0 0 Note. Combined data from two observers. 1 = strongly preferred F-IRIS image, 2 = somewhat preferred F-IRIS image, 3 = no preference, 4 = somewhat preferred H-IRIS image, 5 = strongly preferred H-IRIS image. F/IRIS = full dose image with iterative reconstruction in image space (IRIS, Siemens Healthcare, Erlangen, Germany), H/IRIS = half dose image with iterative reconstruction in image space (IRIS, Siemens Healthcare, Erlangen, Germany) A B C Fig. 1. Standard dose contrast enhanced-chest CT in 77-year-old man (BMI 22 kg/m 2 ) with sequalae of previous inflammation in right upper lobe. A-C. Transverse CT images at 5 mm thickness with full radiation dose reconstructed with (A) filtered back projection (FBP) and (B) image reconstruction in image space (IRIS), and (C) with half radiation dose reconstructed with IRIS. When two readers compared F-FBP (A) and F-IRIS (B) images as reconstruction effect, their preference scores were 5 and 4 for lung 5 mm images, 2 and 3 for mediastinum, 5 and 3 for lung 1 mm images, and 5 and 4 for overall images (not shown). When two readers compared F-FBP (A) and H-IRIS (C) images as reconstruction effect and radiation dose effect, readers preference scores were 4 and 3 for lung 5 mm images, 3 and 3 for mediastinum, 4 and 4 for lung 1 mm images, and 4 and 3 for overall images (not shown). BMI = body mass index, F-FBP = full dose image with filtered back projection, F-IRIS = full dose image with iterative reconstruction in image space, H-IRIS = half dose image with iterative reconstruction in image space with the IRIS technique, and the subjective IQ scores were significantly higher in the F-FBP than in the H-IRIS images. This discrepancy is difficult to explain, although, the distribution of the image noise may have had a greater effect on radiologists preferences than other image characteristics for the overall IQ. In our previous study, the measured image noise of the H-IRIS image was significantly lower than that of the F-FBP images. Alternatively, the discrepancy may be due to the use of different readers in these two studies. Radiologists may have different preferences for the IQ and image characteristics, and then the standards for the evaluation of IQ may be subjective and different from each other. With the same radiation dose setting, both radiologists preferred IRIS over FBP images for the evaluation of the lung parenchyma in both SDCT and LDCT (Tables 3, 4) (Figs. 1-3). In contrast, the readers generally preferred FBP over IRIS images for evaluation of the mediastinum 724 Korean J Radiol 13(6), Nov/Dec 2012 kjronline.org

Iterative Reconstruction in DECT of Chest and Radiologists Preference A B C Fig. 2. Standard dose contrast enhanced-chest CT in 19-year-old man (BMI, 21 kg/m 2 ) with pulmonary hypertension. A-C. Transverse CT images at 1 mm thickness with full radiation dose reconstructed with (A) FBP and (B) IRIS, and (C) with half radiation dose reconstructed with IRIS. When two readers compared F-FBP (A) and F-IRIS (B) images, reconstruction effect, they both had preference scores of 4 and 4 for lung 5 mm images, 3 and 3 for mediastinum, 4 and 3 for lung 1 mm images and 3 and 4 for overall (not shown). When two readers compared F-FBP (A) and H-IRIS (C) images, as reconstruction effect and radiation dose effect, readers preference scores were 4 and each for lung 5 mm images, 3 and 2 each for mediastinum, 4 and 3 for lung 1 mm images and 4 and 3 for overall (not shown). BMI = body mass index, F-FBP = full dose image with filtered back projection, F-IRIS = full dose image with iterative reconstruction in image space, H-IRIS = half dose image with iterative reconstruction in image space A B C Fig. 3. Low dose chest CT in 62-year-old woman (BMI, 27 kg/m 2 ) with postoperative lung cancer. Transverse CT images at 5 mm thickness with full radiation dose reconstructed with (A) FBP and (B) IRIS, and (C) with half radiation dose reconstructed with IRIS. When two readers compared F-FBP (A) and F-IRIS (B) images as reconstruction effect, readers preference scores of 4 and 4 for lung 5 mm images, 3 and 2 for mediastinum, 5 and 4 for lung 1 mm images, and 4 and 4 for overall (not shown). When they compared F-FBP (A) and H-IRIS (C) as reconstruction effect and radiation dose effect, two readers had preference scores of 4 and 4 each for lung 5 mm images, 2 and 3 for mediastinum, 5 and 4 for lung 1 mm images, and 4 and 4 overall (not shown). BMI = body mass index, F-FBP = full dose image with filtered back projection, F-IRIS = full dose image with iterative reconstruction in image space, H-IRIS = half dose image with iterative reconstruction in image space (Tables 2, 3) (Fig. 4). These results are similar to those of our previous study. In the previous study, the subjective IQ in the lung image was generally improved with the IRIS technique, comparing with that of the FBP images with the same radiation dose, and this improvement was more distinct in the images with the reduced radiation dose, whereas the subjective IQ scores for the evaluation of the mediastinum were higher in FBP than in the IRIS images at the same radiation dose. The lower preference for IRIS in the evaluation of the mediastinum seems to be due to an excessive reduction of the image noise in the regularization step of the I30f kernel, with this excessive smoothing effect of the IRIS technique, which affected the subjective IQ. For internal validation of the radiologists preferences, we also included H-IRIS/F-IRIS sets. In most data pairs, the kjronline.org Korean J Radiol 13(6), Nov/Dec 2012 725

Hwang et al. A B C Fig. 4. Standard dose contrast enhanced-chest CT in 77-year-old man (BMI, 22 kg/m 2 ) with esophageal cancer. Transverse CT image at 5 mm thickness with full radiation dose reconstructed with (A) FBP and (B) IRIS, and (C) with half radiation dose reconstructed with IRIS. When two readers compared F-FBP (A) and F-IRIS (B) images, as reconstruction effect, readers preference scores were 2 and 2 each for mediastinum, 4 and 3 for lung 5 mm images, 4 and 3 for lung 1 mm images and 4 and 3 for overall (not shown). When they compared F-FBP (A) and H-IRIS (C) as reconstruction effect and radiation dose effect, readers had preference scores of 2 and 2 each for mediastinum, 4 and 4 for lung 5 mm/1 mm images, and 3 overall (not shown). BMI = body mass index, F-FBP = full dose image with filtered back projection, F-IRIS = full dose image with iterative reconstruction in image space, H-IRIS = half dose image with iterative reconstruction in image space two radiologists consistently preferred the higher radiation dose images in both SDCT and LDCT, and this means that the readers reached consistent results in this study (Table 5). We found that the IRIS technique was effective in reducing the radiation dose in a CT, especially in the lung parenchyma images, and that the two radiologists preferred IRIS images at 50% reduced radiation dose to FBP images, with higher radiation dose. In the recent studies by Pontana et al. (16) and Prakash et al. (17), they also reported the radiation dose reductions in a chest CT by 35% by using an IRIS technique and by 26% to 29% with the adaptive statistical iterative reconstruction technique (different iterative reconstruction technique), retrospectively, without compromising the IQ. In their study, they used a follow up CT scan in same patients or a weight matched CT scan from different patients for the CT images with reduced radiation dose to compare with the initial full dose CT scan with FBP technique. However, at these settings, the differences in the scanning levels, respiration status and lung abnormalities can influence the measurement of image noise and subjective IQ. Moreover, differences in the sizes of thoracic cages and other structures in different patients may affect the subjective IQ, including the image noise. In contrast, we could compare the full dose and reduced dose CT images from CT scans of same patients. These images were obtained at the same time, without additional CT scanning, using the modified dual energy CT scan mode in the dual source CT. This made possible for the evaluation of the image noise and other IQs at the same scanned level and in the same patient without the interference from different CT scan levels or different disease conditions. The importance of this intrapatient comparison, without additional CT scanning, is also described in recent studies (17). Although the radiologists preferred the IRIS images, even at the reduced radiation dose in our study, it is difficult to investigate how much the radiation can be reduced. Because, the quantitative comparisons of IQ are difficult, due to the non-linear image processing algorithm used to reduce the image noise in the IRIS technique, making the appropriate CT imaging characteristics and quality for various different diseases. Together with the results of subjective IQs and reader s preference, we think that it may be possible to reduce the radiation dose by 30 to 40%, which is well agreed with the results of the previous studies (16, 17). Further, according to our preference study, for the evaluation of lung parenchyma, such as lung cancer screening CT or nodule follow up CT, IRIS image with 50% reduced radiation dose can be feasible. This study had several limitations. Firstly, the complete blinding of the radiologists was impossible. Although the radiologists were blinded to the reconstruction method, the characteristics of the IRIS and FBP images were different and the IRIS image was somewhat unique. However, the readers were also blinded to the radiation dose, and we used the various combinations of the each 10/10/40/40 726 Korean J Radiol 13(6), Nov/Dec 2012 kjronline.org

Iterative Reconstruction in DECT of Chest and Radiologists Preference image pairs to weaken this limitation. Secondly, we only evaluated the radiologists preferences for CT images in clinical practice, but we did not evaluate the diagnostic acceptability and lesion conspicuity of the IRIS images. We could demonstrate the improvement or preservation of the general IQ in the IRIS image with the reduced radiation dose does for the lung image, but the influence of the characteristics of the IRIS image on the specific disease pattern is not known. The effect of the IRIS technique on diagnostic performance in patients with abnormal lesions remains to be investigated. Thirdly, BMI of our patient is relatively low due to the characteristics of being Asian; thus, it is uncertain if our results can be generalized for more adipose patients. Finally, we used a DSCT scanner with a modified dual energy mode to evaluate the half dose CT images, without the additional CT scanning. However, the two X-ray tubes and two detector arrays give rise to a cross scattering radiation (7), or the scattering of X-ray photons from one source to the detector array of the other source. Accordingly, cross scattering radiation may have affected the IQ. However, this effect may be negligible because the DSCT scanner we used employs scatter correction algorithms to minimize any cross scattering effect. In conclusion, radiologists preferences for chest CT are influenced by the radiation dose and reconstruction algorithm. According to our preliminary results, dose reduction at 50% with IRIS may be feasible for the lung parenchymal evaluation. REFERENCES 1. Rogers LF. Dose reduction in CT: how low can we go? AJR Am J Roentgenol 2002;179:299 2. Yu L, Li H, Fletcher JG, McCollough CH. Automatic selection of tube potential for radiation dose reduction in CT: a general strategy. Med Phys 2010;37:234-243 3. Greess H, Wolf H, Baum U, Lell M, Pirkl M, Kalender W, et al. Dose reduction in computed tomography by attenuationbased on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol 2000;10:391-394 4. Schenzle JC, Sommer WH, Neumaier K, Michalski G, Lechel U, Nikolaou K, et al. Dual energy CT of the chest: how about the dose? Invest Radiol 2010;45:347-353 5. Lell MM, May M, Deak P, Alibek S, Kuefner M, Kuettner A, et al. High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Invest Radiol 2011;46:116-123 6. Wildberger JE, Mahnken AH, Schmitz-Rode T, Flohr T, Stargardt A, Haage P, et al. Individually adapted examination protocols for reduction of radiation exposure in chest CT. Invest Radiol 2001;36:604-611 7. Kyriakou Y, Kalender WA. Intensity distribution and impact of scatter for dual-source CT. Phys Med Biol 2007;52:6969-6989 8. Kalra MK, Maher MM, Toth TL, Schmidt B, Westerman BL, Morgan HT, et al. Techniques and applications of automatic tube current modulation for CT. Radiology 2004;233:649-657 9. McNitt-Gray MF. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. Radiographics 2002;22:1541-1553 10. Lucaya J, Piqueras J, García-Peña P, Enríquez G, García- Macías M, Sotil J. Low-dose high-resolution CT of the chest in children and young adults: dose, cooperation, artifact incidence, and image quality. AJR Am J Roentgenol 2000;175:985-992 11. Nitta N, Takahashi M, Murata K, Morita R. Ultra low-dose helical CT of the chest. AJR Am J Roentgenol 1998;171:383-385 12. Diederich S, Lenzen H, Windmann R, Puskas Z, Yelbuz TM, Henneken S, et al. Pulmonary nodules: experimental and clinical studies at low-dose CT. Radiology 1999;213:289-298 13. Diederich S, Wormanns D, Semik M, Thomas M, Lenzen H, Roos N, et al. Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 2002;222:773-781 14. Zwirewich CV, Mayo JR, Müller NL. Low-dose high-resolution CT of lung parenchyma. Radiology 1991;180:413-417 15. Hwang HJ, Seo JB, Lee JS, Song JW, Kim SS, Lee HJ, et al. Radiation dose reduction of chest CT with iterative reconstruction in image space - Part I: studies on image quality using dual source CT. Korean J Radiol 2012;13:711-719 16. Pontana F, Duhamel A, Pagniez J, Flohr T, Faivre JB, Hachulla AL, et al. Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients. Eur Radiol 2011;21:636-643 17. Prakash P, Kalra MK, Digumarthy SR, Hsieh J, Pien H, Singh S, et al. Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr 2010;34:40-45 18. May MS, Wüst W, Brand M, Stahl C, Allmendinger T, Schmidt B, et al. Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dualsource computed tomography. Invest Radiol 2011;46:465-470 kjronline.org Korean J Radiol 13(6), Nov/Dec 2012 727