FMP Surgical Technique

Similar documents
Dual Mobility System Surgical technique

Dual Mobility System Evaluation surgical technique

TaperFill. Surgical Technique

Trilogy Acetabular System

OPTIONAL/ADDITIONAL INSTRUMENTS

ACETABULAR CUP SURGICAL TECHNIQUE

Trilogy Acetabular System

Trinity. Advanced Bearing Acetabular System Surgical technique

Surgical Technique. Cup System

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Rx90 Total Hip System Acetabular Series

Taperloc Complete Hip System. Surgical Technique

Manza Cup HA SURGICAL TECHNIQUE.

Cementless Tapered Femoral Stem Surgical technique

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Trilogy Acetabular System

Restoration Anatomic Acetabular System Surgical Technique

Cementless Tapered Femoral Stem Surgical technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

SURGICAL TECHNIQUE IMPROVED WEAR REDUCTION PROVEN FIXATION PRECISE INSTRUMENTATION RELIABILITY

Operative Technique Crown Cup Acetabular System

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

pact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation

Zimmer MMC Cup. Surgical Technique. Large Diameter Metal-on-Metal

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

SURGICAL TECHNIQUE. Pivot Bipolar Solitude Unipolar

Zimmer Maxera Cup. Surgical Technique. This device is not available for commercial distribution in the United States.

Clinical Evaluation Surgical Technique

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Longevity Offset and Oblique Liners. Surgical Technique

*smith&nephew CONTOUR

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

System Surgical Protocol

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

Optimum implant geometry

Duraloc CONSTRAINED LINER

Metasul LDH Large Diameter Head

UNDERSTANDING TRADITION, MASTERING INNOVATION. Surgical Technique

Progeny Hip Stem. Surgical Protocol and Product Specifications

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

Bi-Polar 22.2mm & 28mm System - Operative technique

Integral 180 Surgical Technique

U2 PSA. Revision Knee. Surgical Protocol

HIP SYSTEM SURGICAL TECHNIQUE

Signature Personalized Patient Care

PROCOTYL E Acetabular Cup System. Modular to Fit Patient s Anatomy. Versatile for Revisions.

Modular Unipolar Femoral Head Replacement. Surgical Technique

FLH /11

Zimmer Continuum Acetabular System. Surgical Technique

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Tritanium Acetabular System Surgical Protocol. Cluster Hole Shell Solid Back Shell

Zimmer Continuum Acetabular System. Surgical Technique

Zimmer Continuum Acetabular System. Surgical Technique

Ovation Hip System. Surgical Technique

AVANTEON. Operative Technique & Catalogue Information AVANTEON

Zimmer Trilogy IT Acetabular System

Zimmer Continuum Acetabular System. Surgical Technique

asterloc Surgical Technique HIP SYSTEM UNDERSTANDING TRADITION, MASTERING INNOVATION Hip Knee Spine Navigation

AML Hip System. Design Rationale/ Surgical Technique

ADM X3 Mobile Bearing Hip. System Surgical Protocol. Available with X3 Advanced Bearing Technology. For Use With Restoration ADM Cups and Inserts

TRK REVISION KNEE Surgical Technique

Zimmer Continuum Acetabular System

Surgical Technique. Poly and Ceramic

9800 Metric Blvd. Austin, Texas

A novel cementless option. Zimmer NexGen Trabecular Metal Primary Patella Surgical Technique

Biomet Large Cannulated Screw System

Ceramic Femoral Heads and Acetabular Cup Liners

operative technique Kent Hip

Allofit /Allofit -S IT Alloclassic Acetabular Cup System

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Bone Preservation Stem

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

Active Articulation. Surgical Technique. Dual Mobility Hip System. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Trident All Poly Acetabular System

PLR. Proximal Loading Revision Hip System

Trabecular Metal Primary Patella

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

Trabecular Metal Acetabular Revision System Cemented Constrained Liner

Exeter X3 RimFit Acetabular Cup

SURGICAL TECHNIQUE GUIDE

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Trident. Acetabular System Hemispherical Surgical Protocol

TRABECULAR METAL ACETABULAR RESTRICTOR AND AUGMENT. Surgical Technique

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Surgical technique MkII instrumentation

28 Surgical Technique

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

Scan Bi-Polar 22/28. Operative Technique

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Patella Planing System

ADEPT Extra Fixation Cup. Operative Technique. Delivering Results Through Performance

PAL Pelvic Alignment Level

Talar Dome System Surgical Technique

MITCH TRH System Modular Head Operative Technique

Transcription:

Contents Design Rationale....3 Indications.... 4 Contraindications.... 4 Preoperative Planning.... 4 Surgical Snapshot.... 5 Surgical Technique.... 6 Sizing Chart.... 11 Instrument Guide.... 12 Individual results may vary. DJO Surgical is a manufacturer of orthopedic implants and does not practice medicine. This surgical technique was prepared in conjunction with licensed health care professionals. The treating surgeon is responsible for determining the appropriate treatment, technique(s), and product(s) for each individual patient. 2

System Features THE FMP ACETABULAR SYSTEM CONSISTS OF THE FOLLOWING: Porous hemispherical acetabular shell with clustered screw holes Porous hemispherical acetabular shell without screw holes Porous hemispherical acetabular shell with three spikes Porous hemispherical acetabular shell with multiple screw holes Porous flared rim acetabular shell with clustered screw holes Porous flared rim acetabular shell without screw holes Various compression molded, X-alt, and HXe+ highly Cross-Linked polyethylene liners Constrained Liner 22, 28, 32, 34, 36, 40 and 44mm modular CoCr femoral heads 28, 32, 36, 40 and 44mm BIOLOX delta and BIOLOX OPTION ceramic femoral heads The six metal-backed porous coated acetabular shells feature a thin-wall design allowing for maximum polyethylene thickness of the acetabular liners. All are designed and manufactured with high congruency between the modular liner and the Titanium metal shell. The snap-fit acetabular liners are available in neutral, 10, 20, neutral with a 5mm offset and 10 with a 5mm offset. All Non-Crosslinked liners are sterilized by gamma radiation in a nitrogen-flushed environment. Sterilization of the Highly Cross-Linked Polyethylene Acetabular Liner, and Highly Cross-Linked Polyethylene Vitamin E Acetabular Liner, are performed by hydrogen peroxide gas plasma to achieve a Sterility Assurance Level (SAL) of 10-6. The flared rim shell provides an additional 2mm of press-fit for increased stability, while the spiked cup features three spikes for increased rotational stability. The bipolar features a modular snap-fit design utilizing 22mm and 28mm modular femoral heads. The unipolar heads range in size from 38-64mm and feature five neck adaptor sleeve options. 3

Indications, Contraindications, and Preoperative Planning INDICATIONS Joint replacement is indicated for patients suffering from disability due to: Noninflammatory degenerative joint disease including osteoarthritis and avascular necrosis of the natural femoral head Rheumatoid arthritis Correction of functional deformity Femoral fracture This device may also be indicated in the salvage of previously failed surgical attempts. The constrained acetabular component is indicated for primary or revision patients at high risk of hip dislocation due to a history of prior dislocation, bone loss, soft tissue laxity, neuromuscular disease, or intra-operative instability and for who all other options to constrained acetabular components have been considered. This device is to be used for uncemented applications. supported smooth articulation of the head within the acetabulum; Alcoholism or other addictions; Materials sensitivity; Loss of ligamentous structures; High levels of physical activity (e.g. competitive sports, heavy physical labor); Pregnancy PREOPERATIVE PLANNING Preoperative templates are provided for estimating the optimal acetabular component size. Radiographs should include a full A/P (anterioposterior) and lateral view of the pelvis. As with any surgical procedure, proper radiographs are recommended for accurate templating. The dotted line of the shell represents the outer dimension of the porous shells. The flared rim design is 2mm larger (1mm per side) at the rim (FIGURE 1). CONTRAINDICATIONS Joint replacement is contraindicated where there is: Infection or sepsis; Insufficient bone quality which may affect the stability of the implant; Muscular, neurological or vascular deficiencies, which compromise the affected extremity; Skeletally immature patients and cases where there is a loss of abductor musculature, poor bone stock, poor skin coverage around the hip joint which would make the procedure unjustifiable; Osteomyelitis; Rapid joint destruction or bone absorption apparent on roentgenogram; Pathological conditions of the acetabulum, which would prevent achieving proper range of motion, appropriate head stability, and/or a well-seated and FIGURE 1 4

Surgical Snapshot 1 2 3 Sequentially ream until good contact is made with the cortical rim. Once the final shell implant size has been determined, remove the dome plug using the hexdriver. Attach the shell to the shell impactor and impact into the acetabulum. 4 5 6 If using a cluster hole shell, bone screws may now be implanted. The bone screw must be fully seated to ensure engagement of the trial liner or liner implant. Place the trial liner in the shell implant and fully thread the screw using the hexdriver. Once the liner implant has been selected, impact the liner into the shell until the snap locking mechanism engages. 5

Surgical Technique FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 SURGICAL APPROACH The FMP Acetabular System is designed to accommodate any standard approach based on the surgeon s experience or personal preference. Adequate exposure, which allows bony landmark visualization, component alignment, and thorough soft-tissue assessment should be considered throughout the procedure. ACETABULAR PREPARATION The acetabular rim is exposed by thorough removal of the acetabular labrum. The acetabular fat pad and any osteophytes are removed to identify the true acetabular floor. An acetabular reamer is used to deepen the true acetabular floor. Placing each reamer concentrically into the acetabulum, the reaming progresses until good contact is made with the cortical rim. In a shallow acetabulum, it may be necessary to ream to the medial cortical wall. In an eccentrically deep acetabulum, the cotyloid notch may be left intact. All cysts are curetted and subsequent defects may be packed with cancellous bone obtained from the resected femoral head or acetabular bone reamings. The final reamed diameter should be the same as or 1mm smaller than the selected implant size, depending on the quality of the bone. In normal to sclerotic bone, a line-to-line reaming is sufficient. When using a P2 shell, line-to-line reaming is recommended. In soft bone, under reaming by 1mm may be necessary. If the flared rim cup is selected for implantation, a line-to-line reaming will allow 2mm pressfit around the rim of the acetabulum. If the acetabulum is under reamed by 1mm, a flared rim cup will allow a 1mm press-fit over the hemisphere and a 3mm press-fit around the rim of the acetabulum. Shell trials are available in even sizes in 2mm increments to verify the reamed diameter. The shell trial should make even contact with the rim and walls of the acetabulum and provide feedback that the acetabulum has been prepared adequately for the final implant. ACETABULAR PLACEMENT The dome plug is removed from the acetabular shell (FIGURE 2) and the shell is fully threaded to the shell impactor (FIGURE 3). If a screwhole design shell is selected, the cluster of screwholes may be positioned to the posterior/superior quadrant of the acetabulum. If an alignment guide is used, ensure the alignment rods are aligned with the screwholes. The T-handle is inserted in either the 15 or 20 position depending on the desired degree of anteversion. The alignment rod is threaded into either the left or right alignment hole of the positioner (FIGURE 4). Positioning the T-handle vertical to the floor gives approximately 45 of abduction. Then, positioning the alignment rod parallel to the patient s midline gives approximately 20 or 15 of anteversion depending on the selected position of the alignment rod (FIGURE 5). 6

Surgical Technique FIGURE 6 ACETABULAR PLACEMENT CONTINUED When using the straight cup impactor, part number 803-05-337, (FIGURE 6) one of the three modular impaction tips must be used when impacting the shell. Place the impaction tip over the straight cup impactor threads until you feel it snap into place. The impactor threads should be exposed to screw into the shell. The small tip should be used for shell sizes 40-46mm, the medium tip for 48-58mm, and the large tip for 60-70mm. With this straight cup impactor there are two alignment guide options: supine and lateral. The guides will provide 20 degrees of anteversion (vertical rod for supine guide, horizontal rod for lateral guide) and 45 degrees of inclination (horizontal rod for supine guide, vertical rod for lateral). First, thread an alignment rod into the threaded hole on top of the selected guide. Thread the second alignment rod into either the left or right threaded hole. Place the assembly onto the handle of the impactor with the guide label and description facing the modular impaction tip. Rotate the guide into the desired position and secure by tightening the knob. When the horizontal alignment rod aligns with the patient s spine and the vertical rod is perpendicular to the floor, the handle will be oriented at 20 of anteversion and 45 of inclination. 7

Surgical Technique FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 SCREW PLACEMENT The flexible drill shaft and drill bit are guided by the drill guide through the desired screw hole (FIGURE 7). The drill guide is 15mm in length and the drill bits are available in 45mm or 60mm lengths and 3.2mm or 4.5mm diameters. The working length of the drill bit extending from the drill guide is 30mm and 45mm respectively. A depth gauge is provided to determine the length of the screw needed and to verify that the internal cortex has not been penetrated (FIGURE 8). NOTE: The bone screw must be fully seated to ensure full seating of the trial liner or liner implant. (FIGURE 10). The appropriate cancellous bone screw is inserted using the universal joint screwdriver and the screw forceps (FIGURE 9). 8

Surgical Technique FIGURE 11 FIGURE 12 FIGURE 13 LINER TRIALING AND IMPLANTATION The appropriate liner is determined for joint stability. Polyethylene liners are available in neutral, 10 and 20 hooded, neutral with a 5mm offset, 10 with a 5mm offset, and constrained. The 12-position scallops on the various liners allow independent rotation of the liner to the point where additional femoral head coverage is desired. Trial liners can be threaded into the implant shell so that a trial reduction can be performed to assist in final implant selection (FIGURE 11). At this point, measurements of the offset and neck length can be compared to the preosteotomy measurements, but may need to be adjusted to ensure stability depending on final acetabular component seating and anteversion of the femoral stem. Neck length can be adjusted using the various offsets of the femoral head and offset sleeve implants. NOTE: The use of offset sleeves is required with 34, 36, 40 and 44mm CoCr heads. Once the appropriate liner has been determined, the trial liner can be removed and the dome plug can be replaced into the shell (FIGURE 12). The final liner implant is then impacted into the shell using the liner impactor head that corresponds to the implant head size being used (FIGURE 13). Visually confirm symmetrical seating of the polyethylene liner. An osteotome can be lightly inserted between the shell and the inserted liner. Gently attempt to pry upward on the polyethylene liner. There should be no movement of the liner within the shell. If the liner disengages, repeat the impaction until the snap-feature engages. Range of motion typically increases as femoral head size increases 1. If using a smaller femoral head, it is important to verify that sufficient range of motion is achieved. 9

Surgical Technique BIOLOX DELTA CERAMIC FEMORAL HEADS If a BIOLOX delta femoral head is being implanted, do not remove the plastic protective wrap until immediately before the trial head is used. The BIOLOX delta femoral heads may only be used on brand new, unused femoral stem tapers. Before placing the BIOLOX delta head onto the trunnion of the femoral stem, thoroughly rinse and dry the stem taper. Inspect the stem and inner taper of the ceramic head and carefully remove any tissue, bone, or foreign substances. Lightly twist the BIOLOX delta head onto the trunnion until it sits firmly. Using the plastic femoral head impactor, moderately tap the mallet so the ceramic head is firmly and definitively fixed onto the femoral stem taper. The metal taper becomes plastically deformed during impaction, thus producing an optimal pressure distribution and torsion-resistant fixation. It is essential for safe function that the greatest care is taken when placing the BIOLOX delta femoral head on the stem. NOTE: In very isolated cases, fracture of ceramic components can occur. The cause of this can be an overload on the prosthesis. For example, through incorrect placement of the BIOLOX delta head on the stem taper or a wrong or missing fit between the BIOLOX delta head and the stem taper. If a ceramic femoral head breaks, a pairing of a metal femoral head with a polyethylene liner may not be used for revision. Never impact the BIOLOX delta or BIOLOX OPTION heads with a metal mallet. A plastic femoral head impactor must always be used. Any reuse or re-sterilization of the BIOLOX OPTION femoral heads is not permitted. BIOLOX OPTION CERAMIC FEMORAL HEADS If a BIOLOX OPTION femoral head is being implanted, the stem taper, femoral head sleeve, and ceramic femoral head must be dry and free of any foreign substances: tissue or bone before the final seating. Lightly twist the BIOLOX OPTION head onto the trunnion until it locks. It should be easy to place the femoral head onto the taper and if any pressure is necessary, the implant must not be used. Using the plastic femoral head impactor, moderately tap the mallet so the ceramic head is firmly and definitively fixed onto the femoral stem taper. The interface between the metal sleeve and the stem taper becomes plastically deformed during impaction, thus producing an optimal pressure distribution and torsion-resistant fixation. Ensure the BIOLOX OPTION femoral head is well fixated by attempting to remove the femoral head by hand. When using the BIOLOX OPTION femoral head on an already compromised stem taper, the surgeon must test the taper for its compatibility with the inner taper of the femoral head sleeve. 10

Surgical Technique FIGURE 14 FIGURE 15 If a constrained liner is being used, use standard trial liners and 28mm head trials to determine appropriate femoral head offset. Once the desired sizing has been determined, impact the constrained liner implant using a 28mm ball impactor. To assemble the constrained liner components, first impact the femoral head implant onto the taper of the stem implant. Next, slide the constrained locking ring over the neck of the femoral stem implant so that the locking feature is oriented to correctly engage the liner. Insert the femoral head into the constrained liner (FIGURE 14). Last, snap the locking ring onto the locking scallops of the constrained liner (FIGURE 15). This can be achieved by hand. 11

Reference Guide The FMP system uses letters, colors and numbers to designate compatibility between all components. Matching shell and insert codes will ensure proper compatibility. For more implant part numbers and information, please refer to the Acetabular Reference Guide (catalog number 0020327-001). COLOR/CODE STANDARD SHELL SIZE SPIKED SHELL SIZE ID/HEAD SIZE NEUTRAL/0 10 HOODED 20 HOODED 5MM OFFSET NEUTRAL/0 5MM OFFSET 10 HOODED MIN POLY THICKNESS HXE+ X-ALT HXE+ X-ALT HXE+ X-ALT X-ALT X-ALT STD SHELL MP1* 40 N/A 22mm 5.6mm MP2* 42 N/A MP3 44 N/A MP4 46 N/A MP5 48 48/50 MP6 50 52 MP7 52 54 MP8 54 56 MP9 56/58 58/60 MP10 60/62 62/64 MP11 64/66 66/68 MP12 68/70 70 MP13* 72/74 N/A MP14* 76/78 N/A MP15* 80 N/A HXE+ AND X-ALT HIGHLY CROSS-LINKED LINERS 22mm 6.7mm 28mm 931-28-742 932-28-742 3.8mm 22mm* 7.6mm 28mm 931-28-744 932-28-744 4.7mm 28mm 931-28-746 931-28-246 932-28-746 932-28-246 933-28-746 933-28-246 934-28-246 935-28-246 5.8mm 32mm 931-32-746 932-32-746 3.8mm 28mm 931-28-748 931-28-248 932-28-748 932-28-248 933-28-748 933-28-248 934-28-248 935-28-248 6.1mm 32mm 931-32-748 932-32-748 4.1mm 32mm 931-32-750 931-32-250 932-32-750 932-32-250 933-32-750 933-32-250 5.8mm 34mm 931-34-750 931-34-250 931-36-750 932-34-250 933-34-750 933-34-250 934-34-250 935-34-250 4.8mm 36mm 931-36-750 932-36-750 3.8mm 32mm 431-32-707 432-32-707 433-32-707 6.8mm 36mm 931-36-752 931-36-252 932-36-752 932-36-252 933-36-752 933-36-252 934-36-252 935-36-252 4.8mm 32mm 431-32-708 432-32-708 433-32-708 7.8mm 36mm 931-36-754 931-36-254 932-36-754 932-36-254 933-36-754 933-36-254 934-36-254 935-36-254 5.8mm 40mm 931-40-754 932-40-754 3.8mm 32mm 431-32-709 432-32-709 433-32-709 8.8mm 36mm 931-36-756 931-36-256 932-36-756 932-36-256 933-36-756 933-36-256 934-36-256 935-36-256 6.8mm 40mm 931-40-756 931-40-256 932-40-756 932-40-256 933-40-756 933-40-256 934-40-256 935-40-256 4.8mm 32mm 431-32-710 432-32-710 433-32-710 10.8mm 36mm 931-36-760 931-36-260 932-36-760 932-36-260 933-36-760 933-36-260 934-36-260 935-36-260 8.8mm 40mm 931-40-760 931-40-260 932-40-760 932-40-260 6.8mm 44mm 931-44-760 931-44-260 932-44-760 932-44-260 933-44-760 933-44-260 934-44-260 935-44-260 4.8mm 32mm 431-32-711 432-32-711 433-32-711 12.8mm 36mm 931-36-764 931-36-264 932-36-764 932-36-264 933-36-764 933-36-264 934-36-264 935-36-264 10.8mm 40mm 931-40-764 931-40-264 932-40-764 932-40-264 8.8mm 44mm 931-44-764 931-44-264 932-44-764 932-44-264 933-44-764 933-44-264 934-44-264 935-44-264 6.8mm 32mm 431-32-712 432-32-712 433-32-712 14.8mm 36mm 931-36-768 931-36-268 932-36-768 932-36-268 933-36-768 933-36-268 934-36-268 935-36-268 12.8mm 40mm 931-40-768 931-40-268 932-40-768 932-40-268 10.8mm 44mm 931-44-768 931-44-268 932-44-768 932-44-268 933-44-768 933-44-268 934-44-268 935-44-268 8.8mm 36mm 931-36-772 931-36-272 932-36-772 932-36-272 933-36-772 933-36-272 934-36-272 935-36-272 14.8mm 40mm 931-40-772 931-40-272 932-40-772 932-40-272 12.8mm 44mm 931-44-772 931-44-272 932-44-772 932-44-272 933-44-772 933-44-272 934-44-272 935-44-272 10.8mm 36mm 931-36-776 931-36-276 932-36-776 932-36-276 933-36-776 933-36-276 934-36-276 935-36-276 16.8mm 40mm 931-40-776 931-40-276 932-40-776 932-40-276 14.8mm 44mm 931-44-776 931-44-276 932-44-776 932-44-276 933-44-776 933-44-276 934-44-276 935-44-276 12.8mm 36mm 931-36-780 931-36-280 932-36-780 932-36-280 933-36-780 933-36-280 934-36-280 935-36-280 18.8mm 40mm 931-40-780 931-40-280 932-40-780 932-40-280 16.8mm 44mm 931-44-780 931-44-280 932-44-780 932-44-280 933-44-780 933-44-280 934-44-280 935-44-280 14.8mm 12 *Denotes special request *22mm liners (MP1-MP3) available in compression molded only. *Poly thickness is measured 30 degrees from the dome.

Reference Guide INSTRUMENT GUIDE 2 1 FMP Acetabular Case #1 - Reamers 1. ACETABULAR REAMER HANDLE (X2) 803-05-198 2. ACETABULAR REAMERS 44mm 803-05-199 45mm 803-05-200 46mm 803-05-201 47mm 803-05-202 48mm 803-05-203 49mm 803-05-204 50mm 803-05-205 51mm 803-05-206 52mm 803-05-207 53mm 803-05-208 54mm 803-05-209 55mm 803-05-210 56mm 803-05-211 57mm 803-05-212 58mm 803-05-213 59mm 803-05-214 60mm 803-05-215 61mm 803-05-216 62mm 803-05-217 63mm 803-05-218 64mm 803-05-219 *For smaller or larger reamer information, contact your Customer Service representative. 13

Reference Guide INSTRUMENT GUIDE 1 2 4 3 1 5 2 6 3 4 8 7 5 FMP Acetabular Case #2 - Trial and Screw: Upper Tray FMP Acetabular Case #2 - Trial and Screw: Lower Tray 1. RATCHETING HANDLE 803-05-163 2. U-JOINT MODULAR SHAFT 803-05-164 3. DRILL BITS 3.2 X 60mm 803-05-230 4.5 X 60mm 803-05-232 3.2 X 45mm 803-05-229 4.5 X 45mm 803-05-231 4. BONESCREW DRILL GUIDE 803-05-005 5. SCREW FORCEPS 803-05-136 6. DEPTH GAUGE 801-01-069 7. FLEXIBLE DRILL SHAFT* 803-05-239 8. STRAIGHT HEXDRIVER 803-05-167 *The flexible drill shaft, #7, is now located in the compartment with the straight hexdriver, #8. 1. ACETABULAR TRIAL SHELLS 44mm 803-05-118 46mm 803-05-119 48mm 803-05-120 50mm 803-05-121 52mm 803-05-122 54mm 803-05-123 56mm 803-05-124 58mm 803-05-125 60mm 803-05-126 62mm 803-05-127 64mm 803-05-128 2. ACETABULAR SHELL IMPACTOR/POSITIONER 803-05-137 3. ALIGNMENT ROD 803-01-057 4. LINER IMPACTOR HANDLE 803-05-131 5. TRIAL LINERS, 22MM, 10 HOODED MP2 803-05-042 MP3 803-05-043 MP4 803-05-044 14

Reference Guide INSTRUMENT GUIDE 1 2 X-alt Instrument Case 1: Upper Tray 1. FMP ACETABULAR TRIAL LINERS NEUTRAL 28mm ID 46mm CUP OD 803-51-281 28mm ID 48mm CUP OD 803-51-282 32mm ID 50mm CUP OD 803-51-321 34mm ID 50mm CUP OD 803-51-341 36mm ID 52mm CUP OD 803-51-361 36mm ID 54mm CUP OD 803-51-362 40mm ID 56mm CUP OD 803-51-401 44mm ID 60mm CUP OD 803-51-441 44mm ID 64mm CUP OD 803-51-442 44mm ID 68mm CUP OD 803-51-443 2. FMP ACETABULAR TRIAL LINERS 10 HOODED 28mm ID 46mm CUP OD 803-52-281 28mm ID 48mm CUP OD 803-52-282 32mm ID 50mm CUP OD 803-52-321 34mm ID 50mm CUP OD 803-52-341 36mm ID 52mm CUP OD 803-52-361 36mm ID 54mm CUP OD 803-52-362 40mm ID 56mm CUP OD 803-52-401 44mm ID 60mm CUP OD 803-52-441 44mm ID 64mm CUP OD 803-52-442 44mm ID 68mm CUP OD 803-52-443 15

Reference Guide INSTRUMENT GUIDE 2 3 4 5 6 7 1 8 9 X-alt Instrument Case 1: Lower Tray 1. HXL TRIAL HEADS 22mm +8.0mm 803-84-432 +7.0mm 803-84-436 +7.0mm 803-84-444 +8.0mm 803-84-422 +4.0mm 803-84-332 +3.5mm 803-84-336 +3.5mm 803-84-344 +4.0mm 803-84-322 NEUTRAL 803-84-232 NEUTRAL 803-84-236 NEUTRAL 803-84-244 NEUTRAL 803-84-222-4.0mm 803-84-132-3.5mm 803-84-136-3.5mm 803-84-144 2. HXL TRIAL HEADS 28mm 4. HXL TRIAL HEADS 34mm 6. HXL TRIAL HEADS 40mm 8. CERAMIC TRIAL HEADS 44mm +10.5mm 803-84-528 +10.5mm 803-84-534 +10.5mm 803-84-540 +8.0mm 803-85-444 +7.0mm 803-84-428 +7.0mm 803-84-434 +7.0mm 803-84-440 +4.0mm 803-85-344 +3.5mm 803-84-328 +3.5mm 803-84-334 +3.5mm 803-84-340 NEUTRAL 803-85-244 NEUTRAL 803-84-228 NEUTRAL 803-84-234 NEUTRAL 803-84-240-4.0mm 803-85-144-3.5mm 803-84-128-3.5mm 803-84-134-3.5mm 803-84-140 9. DELTA CERAMIC TRIAL HEAD 32MM, +7.0mm 803-85-432 3. HXL TRIAL HEADS 32mm 5. HXL TRIAL HEADS 36mm 7. HXL TRIAL HEADS 44mm +12.0mm 803-84-532 +10.5mm 803-84-536 +10.5mm 803-84-544 16

Reference Guide INSTRUMENT GUIDE 1 2 4 3 5 6 7 8 9 X-alt Instrument Case 2: Upper Tray 1. LINER IMPACTOR HANDLE (LONG) 803-73-132 2. SLEEVE EXTRACTOR HANDLE* 803-10-007 3. SLEEVE EXTRACTOR* 803-10-003 4. FEMORAL HEAD IMPACTOR HANDLE 803-73-148 5. FEMORAL HEAD IMPACTOR 803-73-147 6. BALL HEAD ADAPTER 22mm 803-73-134 7. LINER IMPACTOR HANDLE (SHORT) 803-73-133 *Numbers 2 and 3 work together to extract the femoral head sleeve. 8. CERAMIC TRIAL HEADS 36mm -4.0mm 803-85-136 NEUTRAL 803-85-236 +4.0mm 803-85-336 +8.0mm 803-85-436 9. CERAMIC TRIAL HEADS 40mm -4.0mm 803-85-340 Neutral 803-85-240 +4.0mm 803-85-340 +8.0mm 803-85-440 17

Reference Guide INSTRUMENT GUIDE 1 2 3 4 X-alt Instrument Case 2: Lower Tray 1. ACETABULAR SOMBRERO LINER IMPACTORS 20 HOOD 28mm 803-04-328 32mm 803-04-332 34mm 803-04-334 36mm 803-04-336 38mm 803-04-338 40mm 803-04-340 44mm 803-04-344 2. ACETABULAR SOMBRERO LINER IMPACTORS 10 HOOD 28mm 803-04-228 32mm 803-04-232 34mm 803-04-234 36mm 803-04-236 38mm 803-04-238 40mm 803-04-240 44mm 803-04-244 3. ACETABULAR SOMBRERO LINER IMPACTORS NEUTRAL 28mm 803-04-128 32mm 803-04-132 34mm 803-04-134 36mm 803-04-136 38mm 803-04-138 40mm 803-04-140 44mm 803-04-144 4. ACETABULAR LINER IMPACTOR BALLS 22mm* 803-73-139 28mm 803-73-140 32mm 803-73-141 34mm 803-73-142 36mm 803-73-143 38mm 803-73-144 40mm 803-73-145 44mm 803-73-146 *Use 22mm ball head adapter (803-73-134) in conjunction with liner ball impactor. 18

Reference: 1. Crowninshield, et al. (2004). Biomechanics of Large Femoral Heads: What They Do and Don't Do. CORR Vol. 429, pp 102-107. Individual results may vary. DJO Surgical is a manufacturer of orthopedic implants and does not practice medicine. This surgical technique was prepared in conjunction with licensed health care professionals. The treating surgeon is responsible for determining the appropriate treatment, technique(s), and product(s) for each individual patient.. DJO Surgical I A DJO Global Company T 800.456.8696 D 512.832.9500 F 512.834.6300 9800 Metric Blvd. I Austin, TX 78758 I U.S.A. djoglobal.com/djosurgical CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. See package insert for a complete listing of indications, contraindications, warnings, and precautions. 2017 Encore Medical, L.P. MKT0020308-001 Rev G 1/18