The publication in January 2001 of the first-in-man

Similar documents
Journal of the American College of Cardiology Vol. 47, No. 7, by the American College of Cardiology Foundation ISSN /06/$32.

Coronary artery disease (CAD) is the REVIEW PROJECTED HEALTH AND ECONOMIC BENEFITS OF THE USE OF SIROLIMUS-ELUTING CORONARY STENTS

S irolimus eluting stents have been recently proved to

DRUG ELUTING STENTS. Cypher Versus Taxus: Are There Differences? Introduction. Methods SIGMUND SILBER, M.D., F.E.S.C., F.A.C.C.

Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study Bagust A, Grayson A D, Palmer N D, Perry R A, Walley T

Sirolimus-Eluting Stents for Treatment of In-Stent Restenosis

Paradigm Shifts in Cardiovascular Medicine

Journal of the American College of Cardiology Vol. 48, No. 2, by the American College of Cardiology Foundation ISSN /06/$32.

2010 Korean Society of Cardiology Spring Scientific Session Korea Japan Joint Symposium. Seoul National University Hospital Cardiovascular Center

HCS Working Group Seminars Macedonia Pallas Hotel, Friday 21 st February Drug-eluting stents Are they all equal?

Drug eluting stents. Where are we now and what can we expect in 2003? Tony Gershlick Leicester

Drug eluting stents From revolution to evolution. Current limitations

NEW INTERVENTIONAL TECHNOLOGIES

Journal of the American College of Cardiology Vol. 46, No. 5, by the American College of Cardiology Foundation ISSN /05/$30.

Significant Reduction in Restenosis After the Use of Sirolimus-Eluting Stents in the Treatment of Chronic Total Occlusions

Long-Term Clinical Outcomes With Sirolimus-Eluting Coronary Stents

The leading cause of death for both men

Clinical Investigations

Angiographic long-term results after implantation of the paclitaxel-eluting coronary stent coroflex please : Data under real-world conditions

C h a p t e r 5 8 Drug Eluting Stents : A New Revolution in the Treatment of Coronary Artery Disease

MULTIVESSEL PCI. IN DRUG-ELUTING STENT RESTENOSIS DUE TO STENT FRACTURE, TREATED WITH REPEAT DES IMPLANTATION

non-diabetic) compared to a 42% rate in the diabetic population assigned to bare metal stents (P=0.001). After 12 months, there was one non-q-wave MI

PCI for In-Stent Restenosis. CardioVascular Research Foundation

Journal of Chemical and Pharmaceutical Research

journal of medicine The new england Sirolimus-Eluting and Paclitaxel-Eluting Stents for Coronary Revascularization abstract

Coronary Heart Disease. Treatment of Left Anterior Descending Coronary Artery Disease With Sirolimus-Eluting Stents

Evolution In Interventional Cardiology. Jawed Polad Jeroen Bosch Hospital s-hertogenbosch The Netherlands

Safety and Efficacy of Coronary Stent Implantation. Acute and Six Month Outcomes of 1,126 Consecutive Patients Treated in 1996 and 1997

In-Stent Restenosis. Can we kill it?

An evaluation of drug eluting (coated) stents for percutaneous coronary interventions;

Gender-Based Outcomes in Percutaneous Coronary Intervention with Drug-Eluting Stents (from the National Heart, Lung, and Blood Institute Dynamic

Controversies in Cardiac Surgery

A Meta-Analysis Of Randomized Controlled Trials With Coronary Drug-Eluting Stents Compared With Bare-Metal Stents

Pathology of percutaneous interventions (PCI) in coronary arteries. Allard van der Wal, MD.PhD; Pathologie AMC, Amsterdam, NL

The BIO revolution: bioadsorbable stents. Federico Conrotto Cardiologia 2 Città della Salute e della Scienza di Torino

Superiority of sirolimus eluting stent compared with intracoronary b radiation for treatment of in-stent restenosis: a matched comparison

Journal of the American College of Cardiology Vol. 48, No. 2, by the American College of Cardiology Foundation ISSN /06/$32.

S ince the advent of coronary balloon angioplasty,

DES in Diabetic Patients

The time period between the first

In-stent Restenosis Diagnostic and Therapeutic Challenges. Kostis Raisakis General Hospital of Athens «G. Gennimatas»

DES In-stent Restenosis

Case Report Coronary Artery Perforation and Regrowth of a Side Branch Occluded by a Polytetrafluoroethylene-Covered Stent Implantation

Journal of the American College of Cardiology Vol. 46, No. 9, by the American College of Cardiology Foundation ISSN /05/$30.

The SYNTAX-LE MANS Study

Coronary Artery Disease 2004, 15: Conflicts of interest: none. Received 3 November 2003 Revised 21 January 2004 Accepted 30 January 2004

IN-STENT RESTENOSIS. K.Boerlage-van Dijk CarVasZ 2014

PCI for Long Coronary Lesion

CYPHER (Polymer-based Sirolimus-eluting DES) New Stent Platforms. Campbell Rogers, M.D. Chief Technology Officer

Economic evaluation of sirolimus-eluting stents Shrive F M, Manns B J, Galbraith P D, Knudtson M L, Ghali W A

BIOFREEDOM: Polymer free Biolimus A9 eluting

Key Words Angioplasty Coronary artery disease Revascularization Stent drug eluting stent

Pathology of Cardiovascular Interventions. Body and Disease 2011

THE CURRENT SITUATION AND FUTURE OF THE PERCUTANEOUS CORONARY INTERVENTION FOR ACUTE CORONARY SYNDROM IN RUSSIAN FEDERATION

INDEX 1 INTRODUCTION DEVICE DESCRIPTION CLINICAL PROGRAM FIRST-IN-MAN CLINICAL INVESTIGATION OF THE AMAZONIA SIR STENT...

Coronary Stents: Past, Present and Future

Results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) Studies

Comparison of Sirolimus Versus Paclitaxel Eluting Stents for Treatment of Coronary in-stent Restenosis F. Airoldi, et al. Am J Cardiol (2006)

Endovascular beta-irradiation with a liquid 188 Re-filled balloon to reduce restenosis after coronary angioplasty.

Journal of the American College of Cardiology Vol. 47, No. 8, by the American College of Cardiology Foundation ISSN /06/$32.

Late Stent Thrombosis Following Implantation of a Drug Eluting Stent Presenting as Acute Myocardial Infarction: A Case Report

Despite its benefit over balloon angioplasty in patients

How to approach non-infarct related artery disease in patients with STEMI in a limited resource setting

Prevention of Coronary Stent Thrombosis and Restenosis

DESolve NX Trial Clinical and Imaging Results

T he RAVEL and the SIRIUS studies, using a

CPT Code Details

Cost-efficacy in interventional cardiology

Update on stents: Recent studies on the TAXUS stent system in small vessels

FFR and IVUS Guided DES Implantation in Long Diffuse Lesions

Case Report Left Main Stenosis. Percutaneous Coronary Intervention (PCI) or Coronary Artery Bypass Graft Surgery (CABG)?

A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents

Unprotected LM intervention

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

P ercutaneous coronary transluminal angioplasty (PTCA)

Index. Note: Page numbers of article titles are in boldface type.

Intravascular Ultrasound in the Drug-Eluting Stent Era

Coronary Artery Disease: Revascularization (Teacher s Guide)

Lessons learned From The National PCI Registry

Influence of Planned Six-Month Follow-Up Angiography on Late Outcome After Percutaneous Coronary Intervention A Randomized Study

Catch-up Phenomenon: Insights from Pathology

Αγγειοπλαστική σε Eπαναστενωτικές Bλάβες

JAMA. 2005;293:

Prospective, randomized controlled study of paclitaxel-coated versus plain balloon angioplasty for the treatment of failing dialysis access

Boston Scientific Corporation Drug-Eluting Stent Program

Resolute in Bifurcation Lesions: Data from the RESOLUTE Clinical Program

Clinical Policy Title: Brachytherapy of coronary arteries

Summary HTA. Drug-eluting stents vs. coronary artery bypass-grafting. HTA-Report Summary. Gorenoi V, Dintsios CM, Schönermark MP, Hagen A

LM stenting - Cypher

Supplementary appendix

Neuestes aus der Therapie der pavk. beschichtete Stents + Ballons. Karls-University. Eberhard-Karls. of Tubingen Department of Diagnostic Radiology

Lesions at coronary bifurcations represent a challenging

Vascular Responses at Proximal and Distal Edges of Paclitaxel-Eluting Stents. Serial Intravascular Ultrasound Analysis From the TAXUS II Trial

Treatment of Left Main Coronary Trifurcation Lesions with the Paclitaxel Drug-Eluting Stent: Mid-Term Outcomes from a Tertiary Medical Center

INSIDE INFORMATION YOU CAN T IGNORE

Turbo-Power. Laser atherectomy catheter. The standard. for ISR

Clinical Considerations for CTO

Interventional Cardiology

Transcription:

MINI-REVIEW: EXPERT OPINIONS Drug-Eluting Stents Cost Versus Clinical Benefit Pedro A. Lemos, MD; Patrick W. Serruys, MD, PhD; J. Eduardo Sousa, MD, PhD The publication in January 2001 of the first-in-man results showing zero restenosis after sirolimus-eluting stent implantation produced enormous excitement in the cardiological community. 1 The long-awaited tool a safe, restenosis-proof, easy-to-use stent had been found. It was not too long thereafter that paclitaxel-eluting stents also demonstrated their capability to decrease restenosis. Today, both sirolimus- and paclitaxel-eluting stents have been shown in randomized trials to reduce restenosis as compared with conventional metallic stents (Figure 1). 2 6 Most of these studies have been recently released in the form of abstracts during medical meetings and are still unpublished. 3,5,6 In addition to sirolimus and paclitaxel, other agents have shown promising early results in recent studies, enlarging the body of evidence demonstrating the potential benefits of what are known as drug-eluting stents. 7 Regulatory agencies have been very active in evaluating some of these devices in the United States, Europe, South America, and Asia. The sirolimuseluting stent has been available for routine use in Europe, South America, and Asia since the first half of 2002 and received approval from the US Food and Drug Administration to be marketed in April 2003. Paclitaxel-eluting stents have also received CE (Conformité Européenne) marking for commercialization in Europe and are now beginning to be commercialized. The case seemed to be closed. Restenosis, the Achilles heel of percutaneous revascularization, appeared defeated. However, since the sirolimus-eluting stents became available, very little has changed in the everyday life of almost all interventional laboratories in Europe. Why? Has the new treatment presented any undesirable effect? Was the desire to defeat restenosis not as great as supposed? The answer is none of the above. The limitation currently impeding more widespread use of the new technology is nontechnical, nonmedical, and nonbiological. The list price of the sirolimus-eluting stent in Europe is 2300 ($2500 US). This high price relative to bare stents, as well as the absence of incremental reimbursement in most countries, has been an obstacle to more widespread utilization of drug-eluting stents. Restenosis: The Problem Coronary restenosis has long been considered the main limitation hampering the efficacy of percutaneous revascularization. Although stent implantation has been shown to reduce restenosis in vessels with reference diameter 3.0 mm, as compared with balloon angioplasty, in-stent restenosis still occurs in 10% to 40% of the patients. In the last 3 decades, a great deal of money and effort has been expended evaluating an endless list of failed concepts, strategies, devices, and drugs to decrease restenosis. But is in-stent restenosis really so bad? The occurrence of restenosis remains largely unpredictable for any particular patient, although powerful predictors of restenosis have been described that are helpful to characterize a population of patients. Furthermore, in-stent restenosis has a high recurrence rate. In its most complex forms, repeat restenosis may occur in up to 50% to 80% after redilatation with balloon, rotablator, or laser. Brachytherapy has been demonstrated to reduce the incidence of repeat restenosis. However, the use of brachytherapy has been restricted to a relatively small number of centers. The need for a multidisciplinary approach, with addition of radiation oncologists and The opinions expressed in this article are not necessarily those of the editors or of the American Heart Association. From the Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands (P.A.L., P.W.S.), and Institute Dante Pazzanese of Cardiology (J.E.S.), São Paulo, Brazil. Reprint requests to Prof P.W. Serruys, MD, PhD, Thoraxcenter, Bd 406, Dr Molewaterplein 40, NL-3015 GD Rotterdam, Netherlands. E-mail p.w.j.c.serruys@erasmusmc.nl (Circulation. 2003;107:3003-3007.) 2003 American Heart Association, Inc. Circulation is available at http://www.circulationaha.org DOI: 10.1161/01.CIR.0000078025.19258.28 3003

3004 Circulation June 24, 2003 Figure 1. Randomized trials showing reduction of binary restenosis with drug-eluting stents. 2 6 physicists to the interventional team, poses logistic limitations to the implementation of the technology as a standard therapy in most hospitals. Nevertheless, although effective for most patients, treatment failure still occurs in 30% of cases after brachytherapy. Patients with restenosis frequently express the recurrence of symptoms as a déjà vu phenomenon occurring unexpectedly in their daily life, with rapidly progressive new-onset angina or so-called unstable angina pectoris. However, unlike patients with de novo lesions, in which plaque rupture and thrombus formation are the underlying substrates, unstable angina due to restenosis is related to rapidly progressive lumen renarrowing as a result of exaggerated neointimal growth. As a consequence, restenosis is rarely complicated by myocardial infarction or death, 8 as in the natural history of unstable patients with de novo lesions. Instead, refractory angina pectoris is the main complication of untreated restenosis. The lack of any effect of restenosis on mortality is readily appreciated by the comparison of angioplasty versus surgery. 9 In most randomized trials, death and myocardial infarction rates were virtually identical between the 2 treatment modalities despite a much higher rate of repeat intervention resulting from restenosis after angioplasty. It is therefore unlikely that reduction of restenosis would have a direct impact on myocardial infarction or mortality rates. 5 An anticipated high risk of in-stent restenosis is one of the major reasons for patients refusing angioplasty and opting for other treatment modalities (eg, surgery or medical). Similarly, the potential occurrence of restenosis currently limits the use of percutaneous treatment for conditions such as intermediate lesions and vulnerable plaques. The introduction of drugeluting stents will hopefully broaden the selection of appropriate candidates for angioplasty, with a shift of patients from medical and surgical treatments toward percutaneous intervention. Drug-Eluting Stents: What Are the Benefits? In the first-in-man study 10 and in the RAndomized study with the sirolimus-eluting Bx VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions (RAVEL), 2 which included patients with single, noncomplex de novo lesions, the rate of binary angiographic restenosis (diameter stenosis 50%) after sirolimus-eluting stent implantation was zero at 2 years and at 6 months, respectively. The efficacy of sirolimus-eluting stents was confirmed in the subsequent multicenter randomized double-blind study of the sirolimus-coated Bx Velocity stent in the treatment of patients with de novo coronary artery lesions (SIRolImUS-eluting Bx velocity balloon expandable stent trial; SIRIUS). In this study, in-stent binary restenosis (within the margins of the stent) was reduced by 91% (3.2% versus 35.4%; P 0.01) and in-segment restenosis (including the stented portion and the 5-mm segments proximal and distal to the stent) were reduced by 75% (8.9% versus 36.3%; P 0.01). 5 In the SIRIUS trial, long lesion length, small reference vessel size, and diabetes were shown to be independent predictors of increased risk of restenosis (in stent and in segment), in patients treated either with sirolimus-eluting stents or with bare stents. However, sirolimus-eluting stents markedly reduced restenosis for patients at both extremes of the risk spectrum. Nondiabetics with short lesions ( 12 mm) and large vessels ( 3.0 mm) had an 81.7% risk reduction of in-segment restenosis, whereas patients at the highest risk (diabetics with longer lesions [ 15 mm] and small vessels [ 2.5 mm]) had a significant 64.5% decrease in the risk of restenosis. Similarly, in the RAVEL trial, 11 patients with vessel size 2.36 mm (one third of the population) presented with the same rate of binary restenosis (ie, no restenosis) as patients in the upper tertile (reference diameter 2.84). Recently, sirolimus-eluting stents have shown promising results for the treatment of in-stent restenosis in a series of 25 patients with relatively simple lesions (4% binary restenosis rate at 1 year). 12 Sirolimus-eluting stents have also been evaluated for highly complex patients with in-stent restenosis. In an initial experience with 16 patients (including 50% with multiple previous interventions, 44% needing implantation of 36-mm sirolimus-eluting stents, 25% with failed brachytherapy, 19% with total occlusions, and 6% with transplant vasculopathy), the binary restenosis rate at 4 months was 20% and the death rate was 12.5% at 9 months. 13 Non-polymer coated paclitaxel-eluting stents have been shown to reduce binary angiographic restenosis in the European evaluation of a Taxol-Eluting Stent trial (ELUTES) 3 and the ASian Paclitaxel-Eluting stent Clinical Trial (ASPECT). 4 In these studies, non-polymer paclitaxel stents (high-dose formulation) were associated with 3% and 4% binary angiographic restenosis rates, respectively, versus 21% and 27% in bare stent controls. 3,4 Polymer-covered paclitaxel-eluting stents have been evaluated in the multicenter, randomized treatment of de novo coronary disease using a single paclitaxel-eluting Stent trial-ii (TAXUS II). 6 In this study, the incidence of in-segment restenosis at 6 months was reduced from 20% and 24% in the bare stent group to 6% and 9% in the slow- and moderate-release paclitaxel stent formulations, respectively. However, when patients treated only with the study stent were analyzed,

Lemos et al Drug-Eluting Stents: Cost vs Benefit 3005 restenosis was observed in only 2% in the slow-release and 1% in the moderate-release paclitaxel stents. These results confirmed the previous findings of the smaller TAXUS I trial, 14 in which patients treated with the slow-release polymer-covered paclitaxel stents showed no restenosis, as compared with 10% in the control group. Drug-Eluting Stents: Where Are the Side Effects? In 2 recent reports from the same series of patients, Liistro et al 15 and Virmani et al 16 have described a late catch-up phenomenon after implantation of a high-dose (800- g) paclitaxel-derivative QP2-eluting stent. The restenosis rate was 13% at 6 months and 62% at 12 months. Histological analysis showed signs of delayed healing with active inflammation still present at 1 year. However, the authors emphasized that potential problems such as the non-erodable thick polymer sleeve, very high concentration of the active drug, extended release kinetics, open stent architecture, and inhomogeneous drug delivery (possibly affected by the interspace polymer sleeve) may have compromised the performance of the QuaDS-QP2 stent and concluded that...the overall clinical success of any drug-eluting stent may be dependent on multiple design factors and not the drug alone. Short-term as well as long-term efficacy should be evaluated separately for each drug-eluting stent, given that a class effect is unlikely to occur because of the myriad possible variations in the complex metallic platform/polymer (or not)/pharmacologic agent. Indeed, a number of drug-eluting stents have already been proven ineffective in reducing restenosis, with even worse results being reported, as compared with conventional bare stent. 17 To date, the sirolimuseluting stent has the largest body of data and longest period of follow-up. The first-in-man study has shown persistent positive results up to 2 and 3 years, without any evidence of late catch-up restenosis. 10,18 In the RAVEL trial, 2 no further events due to restenosis were observed between 6 months and 1 year. With paclitaxel, no rebound effect was seen from 6 to 12 months in the TAXUS I, ELUTES, and ASPECT trials. 3,4,14 Obviously, a very delayed loss of the initial benefit, for instance after 3 4 years, cannot yet be ruled out. However, in this hypothetical setting, should a repeat intervention after 3 years be viewed as a therapeutic failure? In a recent analysis of surgically treated patients with multivessel disease included in the Bypass Angioplasty Revascularization Investigation (BARI), 19 significant stenoses were detected after 4 years in 10% to 15% of internal mammary grafts and 25% to 30% of saphenous vein bypass grafts. It seems clear that a meaningful comparison between the results of treating multivessel disease with drug-eluting stents versus surgical revascularization will need an extended period of follow-up to fully assess the differences (or similarities) in outcomes with the 2 strategies. In the first-in-man and RAVEL trials, no binary angiographic restenosis was observed. 1,2 However, in the subsequent SIRIUS trial, restenosis (in-segment) did occur in 9% of the cases. Indeed, in diabetics with small vessels and long lesions, in-segment restenosis was observed in 23.7% of cases. Does this mean that sirolimus-eluting stents are not restenosis proof? The populations treated in the first-in-man and RAVEL trials (no restenosis) and in the SIRIUS trials (some restenosis) were significantly different in terms of their intrinsic risk of restenosis. SIRIUS included patients with a higher risk profile and more complex lesion anatomy. It seems logical to assume that these differences in baseline characteristics could justify, at least in part, the differences in outcomes between the 2 studies. However, if so, what would be the performance of the new device in the real world, where complex cases are the rule? In everyday practice, will the effects still be worth the cost of the new treatment? To evaluate this question, the sirolimus-eluting stent has been used as the device of choice for every percutaneous intervention in Rotterdam since April 2002, as part of the RESEARCH (Rapamycin- Eluting Stent Evaluated At Rotterdam Cardiology Hospital) registry. 20 Patients were treated without clinical or anatomic restriction, and the incidence of major adverse cardiac events is to be evaluated (defined as death, nonfatal myocardial infarction, or repeat revascularization). In this study, sirolimus-eluting stent implantation was observed to be safe in patients with acute coronary syndromes, with a 30-day major adverse cardiac event rate similar to that of a control group treated with bare stents (6.1% versus 6.6% respectively; P 0.8). 20 In a preliminary analysis of the 6-month outcomes of the first 280 patients enrolled, including patients with multivessel stenting, acute myocardial infarctions, total occlusions, bifurcation lesions, and in-stent restenosis, the incidences of target vessel revascularization and major adverse cardiac events were 2.9% and 6.7% respectively. Although promising, these preliminary long-term results must be interpreted with caution until final results are available. In the RAVEL trial, stent malapposition (as observed by intravascular ultrasound) was more frequent at 6 months in sirolimus-eluting stent patients than in the control arm. 21 Moreover, in SIRIUS, 5 late acquired stent malapposition was more commonly observed in the sirolimus group. However, in TAXUS II 6 patients treated with bare stents or with paclitaxel-eluting stents, there were similar rates of lateacquired malapposition. Nevertheless, these ultrasound observations of late malapposition have not been associated with any adverse events throughout the follow-up period in any of these studies. Drug-Eluting Stents: The Costs Developmental and research costs, acquisition of exclusive and expensive licenses from pharmaceutical companies, building of new manufacturing facilities, and low production yield in the early stages of the new product are all cited as reasons to explain the high cost of drug-eluting stents.

3006 Circulation June 24, 2003 Figure 2. Probability ellipses concerning both costs and effects at 1 year of sirolimus-eluting stent (SES) vs bare stent in the RAVEL trial. The outer ellipse defines the smallest area containing both costs and effects with 95% probability, the middle ellipse with 50%, and the inner ellipse with 5%. However, at the present stage, the real economic value of drug-eluting stents is still unclear, as is the profit made by the leading industries manufacturing these devices. In an analysis from the RAVEL trial (B.A. van Hout, PhD, Academic Medical Center Utrecht, Julius Center, Utrecht, the Netherlands, personal communication, October 2002), the utilization of the sirolimus-eluting stent resulted in a mean additional procedural cost of 1286, as compared with the control group based on costs in the Netherlands. However, because of the decrease in reinterventions attributable to the sirolimuseluting stent at the end of the first year of follow-up, the estimated cost difference had decreased to 54. In other words, in the RAVEL trial, the reduction of major event risk from 28.8% to 5.8% after placement of the sirolimus-eluting stent was accomplished at an extra cost of 54 per patient. To account for the so-called oculostenotic reflex that could have artificially increased the rate of reinterventions because of the protocol-mandated angiographic follow-up, both costs and effects were corrected on the basis of the data from the BElgium NEtherlands STENT II (BENESTENT II) study. In this analysis, after 1 year the adjusted event rates were 16.9% and 5.8% in the bare and sirolimus groups, respectively, and the sirolimus-eluting stent was associated with an additional cost of 166 per patient. The balance between costs and effects seemed highly attractive (Figure 2), with a minimal increase in costs for an 60% risk reduction in the worst-case scenario. For comparison, previous studies evaluating the anti-restenotic effect of conventional stents have shown only a 30% risk reduction of adverse event as compared with balloon dilatation, at an additional cost after 1 year of $1000 US per case. 22 The cost and effect estimations derived from the RAVEL trial cannot be directly extrapolated to other situations. In this study, only simple lesions were treated with implantation of a single stent, and the late target lesion revascularization was zero. The balance between costs and effects in more complex situations, in which restenosis may occur in a small but sizable number of patients, has to be specifically analyzed. Furthermore, the number of stents used per procedure may markedly increase procedural costs, potentially limiting the use of this new technology for the treatment of multivessel disease. It is estimated that 1 000 000 percutaneous interventions are performed each year in the United States, and 80% of these patients receive stents. Assuming a 100% usage of drug-eluting stent, at a rate of 1.5 stents per patient and a potential $2000 US difference between drug-eluting and bare stents, an extra $2.4 billion would be added in procedural costs per year. With a 15% reduction in reinterventions (at a cost of $10 000 to $12 000 per procedure for repeat percutaneous coronary procedure and $20 000 to $30 000 per procedure for coronary bypass surgery), the cost offset with unrestricted usage of drug-eluting stents in the patients at present receiving bare metal stents would be $1.5 billion each year. However, if there is any substantial movement from coronary bypass surgery to drug-eluting stents, additional savings from avoiding the high cost of bypass surgery could potentially result in an attenuation of net costs for payors. Nevertheless, although potentially cost effective in reducing repeat revascularization, it is clear that utilization of drug-eluting stents will require a redistribution of budgets and priorities in the health system as a whole, with a shift of an enormous amount of money to manufacturers. This phenomenon is likely to be repeated with the introduction of other new technologies that can replace open surgical procedures with less invasive, technologically driven procedures and will continue to present a challenge for the foreseeable future. Historically, all relevant technological innovation in interventional cardiology has been incorporated into clinical practice. Today, an arsenal of multiple types of guiding catheters, new-generation contrast agents, steerable guidewires, adjunctive medications, intracoronary diagnostic tools, dilatation devices, distal protection devices, and access closure devices encompass the armamentarium of what has been named percutaneous intervention, only vaguely resembling the first days of coronary angioplasty. The speed with which new technologies are integrated over time seems to be dependent on their efficacy, safety, and economic factors and varies from country to country. Curiously, as performed in the late 1980s in Europe, balloon angioplasty was associated with a procedural cost of $4300 US, 23 whereas in the mid-1990s, coronary stenting was performed at a cost of $4400 US. 22 History has shown that an outsider (i.e., a company not belonging to the leading corporations) may unexpectedly introduce a competitive and successful product with a lower price so that the major companies are compelled to reduce the price of their own products, triggering an overall lowering of the costs. We foresee that some of the manufacturers of new eluting-stent designs may purposely target the non-us market with lower regulatory barriers as a profit-

Lemos et al Drug-Eluting Stents: Cost vs Benefit 3007 able field of expansion, so that the non-us patient in Europe, South America, Far East, and Africa may soon benefit from a low-priced, non Food and Drug Administration-approved drug-eluting stent. Conclusions By dramatically decreasing the rate of restenosis, drugeluting stents constitute one of the most important advances in interventional cardiology. However, at present, cost constraints and lack of incremental reimbursement have limited their utilization in daily practice in many countries, although initial analyses of the sirolimus-eluting stent have shown a highly favorable cost-effectiveness profile in reducing repeat revascularization and combined major cardiac events. A more comprehensive understanding of the impact of the new treatment in a wide variety of patients, as well as market competition with changes in the cost of these devices, is likely to redefine the relationship between costs and benefits. Acknowledgments We thank Prof Ben van Hout, Dr Brian Firth, and Dr Angela Hoye for their careful review of the manuscript. References 1. Sousa JE, Costa MA, Abizaid A, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation. 2001;103:192 195. 2. Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002;346:1773 1780. 3. de Scheerder I, Gershlick A, Chevalier B, et al. The Elutes Clinical Study: 12-month clinical follow-up. Circulation. 2002;106(suppl II):II-394. Abstract. 4. Park SJ, Shim WH, Ho D, et al. A paclitaxel-eluting stent for the prevention of coronary restenosis. N Engl J Med. 2003;348:1537 1545. 5. Leon MB, Moses JW, Popma JJ, et al. A multicenter randomized clinical study of the sirolimus-eluting stent in native coronary lesions: angiographic results. Circulation. 2002;106(suppl II):II-393. Abstract. 6. Sousa JE, Serruys PW, Costa MA. New frontiers in cardiology: drugeluting stents: part II. Circulation. 2003;107:2383 2389. 7. Sousa JE, Abizaid A, Abizaid AS, et al. First clinical experience with 17- estradiol-eluting Biodivysiomatrix LO stent to prevent restenosis in de novo native coronary arteries: early clinical outcomes and angiographic follow-up from the Easter Trial. Circulation. 2002;106(suppl II):II-393. Abstract. 8. Doucet S, Malekianpour M, Theroux P, et al. Randomized trial comparing intravenous nitroglycerin and heparin for treatment of unstable angina secondary to restenosis after coronary artery angioplasty. Circulation. 2000;101:955 961. 9. Serruys PW, Unger F, Sousa JE, et al. Comparison of coronary-artery bypass surgery and stenting for the treatment of multivessel disease. N Engl J Med. 2001;344:1117 1124. 10. Degertekin M, Serruys PW, Foley DP, et al. Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up. Circulation. 2002;106:1610 1613. 11. Regar E, Serruys PW, Bode C, et al. Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size. Circulation. 2002;106: 1949 1956. 12. Sousa JE, Costa MA, Abizaid A, et al. Sirolimus-eluting stent for the treatment of in-stent restenosis: a quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation. 2003;107: 24 27. 13. Degertekin M, Regar E, Tanabe K, et al. Sirolimus-eluting stent for treatment of complex in-stent restenosis: the first clinical experience. J Am Coll Cardiol. 2003;41:184 189. 14. Grube E, Silber S, Hauptmann KE, et al. TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slowrelease paclitaxel-eluting stent for de novo coronary lesions. Circulation. 2003;107:38 42. 15. Liistro F, Stankovic G, Di Mario C, et al. First clinical experience with a paclitaxel derivate-eluting polymer stent system implantation for in-stent restenosis: immediate and long-term clinical and angiographic outcome. Circulation. 2002;105:1883 1886. 16. Virmani R, Liistro F, Stankovic G, et al. Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans. Circulation. 2002;106:2649 2651. 17. Babapulle MN, Eisenberg MJ. Coated stents for the prevention of restenosis: part II. Circulation. 2002;106:2859 2866. 18. Sousa JE, Abizaid A, Abizaid A, et al. Late (three-year) follow-up from the first-in-man (FIM) experience after implantation of sirolimus-eluting stents. Circulation. 2002;106(suppl II):II-394. Abstract. 19. Schwartz L, Kip KE, Frye RL, et al. Coronary bypass graft patency in patients with diabetes in the Bypass Angioplasty Revascularization Investigation (BARI). Circulation. 2002;106:2652 2658. 20. Lemos PA, Lee CH, Degertekin M, et al. Early outcome after sirolimuseluting stent implantation in patients with acute coronary syndromes: insights from the Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. J Am Coll Cardiol. 2003;41: 2093 2099. 21. Serruys PW, Degertekin M, Tanabe K, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation. 2002;106:798 803. 22. Serruys PW, van Hout B, Bonnier H, et al. Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II). Lancet. 1998;352: 673 681. 23. van den Brand M, van Halem C, van den Brink F, et al. Comparison of costs of percutaneous transluminal coronary angioplasty and coronary bypass surgery for patients with angina pectoris. Eur Heart J. 1990;11: 765 771.