ihealth PO3 Fingertip Pulse Oximeter OPERATION GUIDE INDEX

Similar documents
Wireless Body Analysis Scale

HeroTracker Sensor for Diskus Instruction Manual

HeroTracker Sensor Instruction Manual

1 1 U S E R M A N U A L

Remote control 2 guide

Kenek Edge Pulse Oximeter System. LionsGate Technologies, Inc. User Manual

Getting started with Wireless Fitting

Cyrus soundkey User Instructions Contents

Over view. Wrist Placement.

Cyrus soundkey User Instructions Contents

Pretend & Discover Doctor s Kit TM

Phonak PilotOne II. User Guide

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Connect with EatSmart

ProPocket TM. User Guide

User s Manual. Model No. NTMPADS15.0 Model No. NTMPAD16.0

ADC Diagnostix 2150 Pediatric Fingertip Pulse Oximeter

MANUAL

User manual. TARGET GOAL, SLEEP MONITORING and monitor your activity for both day and night.

User Manual CentrePoint Data Hub

TH CROS RIC 19 Transmitter. User Guide

Finger Pulse Oximeter. User Manual. Einstein Associates LLC Stafford Centre Drive Suite B Stafford, TX

Zacurate CMS 500DL. Finger Pulse Oximeter. User Manual

Wireless accessories. Remote Control 3.0. Instructions for use

Safety manual for hearing instruments

Medisign GH83 BT Blood Glucose Monitoring System User Manual

Energy Fitness Tracker. User Manual EFT 1

Nokia BPM. Blood Pressure - Heart rate Measurement. Installation and Operating Instructions EN - 1. Nokia BPM. v2.0 January 2018

Flex-Point HEATED MUSCLE MASSAGER

Gocap System User s Guide

Precision GetFit. Digital Body Fat Bathroom Scale. EatSmart Products Seattle, WA

Contents Safety Instructions... 4 Package Contents... 6 Notes on Measurements... 7

IMPORTANT SAFETY INSTRUCTIONS

easypocket Version 2 User Guide Life sounds brilliant.

The Smart Blood Pressure Monitor. Instruction manual

Instructions to User

Wireless Blood Pressure Monitor

Your umic. Thank you. Hearing healthcare professional: Telephone: Serial number of umic: Warranty: Date of purchase:

SUPER CPAP POWER PACK

User Manual for Nox Smart Sleep System

LionsGate Technologies, Inc. User Manual

RC-A. Remote Control. Instructions for Use

Align Gluco-Monitoring System (BG1) Quick Start Guide

Ava Fertility Tracker User Manual Version 5.0. Not for contraceptive use.

SOUNDCLIP-A. Instructions for Use

OTOPod ProgLink. Quick Guide

Getting to Know Your System Kit

Unitron remote control guide

Congratulations on your journey to better hearing

TruHearing app - Tinnitus Manager user guide

GN Hearing app - Tinnitus Manager user guide

Sleep better. User Manual

Behind-the-Ear hearing aids. User Guide

User Manual second language

Align Gluco-Monitoring System (BG1) OWNER S MANUAL. For in vitro diagnostic use only Read instructions before use for self-testing

This user guide is valid for: CE mark applied Wireless models Phonak CROS II-312 Custom Phonak CROS II-13 Custom

Wireless Smart Gluco-Monitoring System (BG5) OWNER S MANUAL. Wireless Smart Gluco-Monitoring System (BG5) OWNER S MANUAL.

Align Gluco-Monitoring System (BG1) Quick Start Guide

Pure 312 Nx, Pure 13 Nx

TH Premium RIC LI 19. Guide for Hearing Care Professionals

Ava Fertility Tracker User Manual Version 4.0. Not for contraceptive use.

ECG Check Wireless 1- Lead Cardiac Monitor. Rx Use

Ring Around The World

1. Welcome Hearing system description 10

Ava Fertility Tracker User Manual Version 2.0. Not for contraceptive use.

Frequently asked questions to Oticon ConnectClip

Quick Start Guide. Congratulations on your journey to better hearing

Digital Blood Pressure Monitor. Model UA-767 BT

Phonak CROS B Custom. User Guide

Blood Glucose Monitoring System. User Guide

Blood Pressure Monitor User Manual

Smart Control remote guide

Instruction Manual! anote! 2013 Audicus Inc, All Rights Reserved!

Smart Scale User Manual

ECG Check Universal Wireless 1-Lead Cardiac Monitor. OTC Use

PLUS One. Blood Glucose Monitoring System. Owner s Manual

User's Manual. LEICKE Sharon Body Fat Analyser. Product number: LH67301

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Phonak Audéo Q (Q90/Q70/Q50/Q30) User Guide

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Withings Aura. Sleep Assistant - Sleep Analyzer. Installation and Operating Instructions (Android users) Withings Aura

Pivotal Living Bluetooth Smart Scale. User Manual

HANSATON stream remote App User Guide. HANSATON stream remote App User Guide

Medical Test Supply. User Manual. Wrist Pulse Oximeter OX-610A

Chair Massager With Heat Instructions

Charging base guide. A Sonova brand

User Manual RECHARGEABLE KIT. Includes: 1 PLUS+ rechargeable pack 2 PLUS+ batteries 1 wall charger 1 USB cable 3 Classic Tobacco flavor tanks

SLEEP IMPROVING WRISTBAND. Item No Owner s Guide

User Guide. A guide for using the Eversense Continuous Glucose Monitoring System. Sensor Smart Transmitter Mobile App

Dear HighQ Check System Owner :

QuietOn_userguide_EN_ _print.pdf :25:51 QUICK START GUIDE

Zeo is the world s fi rst personal sleep coach, designed to help

Orion S, Orion M, Orion P, Sirion S, Sirion M, Sirion P

Blood Glucose Monitoring System

Fraser Health Authority Accu-chek Inform II: Training Script

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

Phonak Naída Link CROS. User Guide

Quick guide for Oticon Opn & Oticon ON App 1.8.0

Custom instruments. Insio primax User Guide. Hearing Systems

Transcription:

ihealth PO3 Fingertip Pulse Oximeter OPERATION GUIDE INDEX INTRODUCTION AND INTENDED USE...2 CONTENTS AND DISPLAY INDICATORS...2 PRODUCT DESCRIPTION...3 SPECIFICATIONS...3 CAUTIONS...3 Cautions...3 USING YOUR PULSE OXIMETER...5 CARE AND MAINTENANCE...6 TROUBLESHOOTING...6 IMPORTANT INFORMATION REQUIRED BY THE FCC...7 EXPLANATION OF SYMBOLS ON DEVICE...7 SERVICE CENTER...8 1

INTRODUCTION AND INTENDED USE Thank you for selecting ihealth Pulse Oximeter product. PO3 is intended to measure blood oxygen saturation (SpO 2 %)(the amount of oxygen in your blood) and pulse rate(bpm). It is designed for adult and can be used in family, homecare, commdevicey care. The PO3 is a medical device and is not intended to diagnose or treat any medical condition or disease. This Bluetooth pulse oximeter can be used with an ipod, iphone or ipad. iphone and ipod touch are trademarks of Apple Inc., registered in the U.S. and other countries. ipad is a trademark of Apple Inc. The ihealth Bluetooth pulse oximeter is designed for the following models: ipod touch 5th generation iphone 4S iphone 5 New ipad ipad 4 The ios version of these device should be V5.0 or higher. ihealth is a trademark of ihealth Lab Inc. CONTENTS AND DISPLAY INDICATORS 2

PRODUCT DESCRIPTION Pulse oximeter measures the amount of oxygen in your blood and the pulse rate. The oximeter works by shining two light beams into the small blood vessels or capillaries of the finger, reflecting the amount of oxygen in the blood and displaying the measurement on the screen. The oxygen saturation(spo2) is measured as a percentage of full capacity. Typically, a SpO2 reading between 96%-99% is considered normal. High altitudes and other factors may affect what is considered normal for a given individual. SPECIFICATIONS 1. Model: PO3 2. Display System: LED 3. Power Source: Battery 3.7V Li-ion 330mAh 4. peak wavelength: 660nm/880nm; 5. SpO2 Measuring Range: 70-99% 6. Average Root Mean Square(A RMS) of SpO2 Accuracy: 70-99%, <2 digits; <70%, no definition. 7. Pulse Rate Measuring Range: 30-250bpm 8. Pulse Rate Accuracy: ±2bpm or ±2% larger one 9. Automatic Shut-off: After 8 seconds of no indication on the sensors 10. Operation Environment: 5-40 ; Humidity <80% 11. Storage Environment: -20-55 ; Humidity <95% CAUTIONS Cautions 1. Do not use the pulse oximeter in a magnetic resonance(mr) environment. 2. The pulse oximeter might misinterpret excessive movement as good pulse strength. Limit finger movement as much as possible when using the device. 3. Do not use the pulse oximeter on the same hand/arm when using a blood pressure cuff or monitor. 4. The pulse oximeter has no alarms and it will not sound if the amount of oxygen in your blood is low or if your pulse is too high or too low. 3

5. The pulse oximeter must be clean for a proper reading. 6. Your finger must be clean for proper reading. 7. Any of the following conditions may cause inaccurate measurements of the pulse oximeter, BUT NOT LIMITED TO: - Flickering or very bright light; - Poor blood circulation; - Low hemoglobin; - hypotension, severe vasoconstriction, severe anemia or hypothermia - Nail polish, and/or artificial nails; and - Any tests recently performed on you that required an injection of intravascular dyes 8. The pulse oximeter may not work if you have poor circulation. Rub your finger to increase circulation, or place the device on another finger. 9. The pulse oximeter measures oxygen saturation of functional hemoglobin. High levels of dysfunctional hemoglobin(caused by sickle cell anemia, carbon monoxide, etc.) could affect the accuracy of the measurements. 10. Do not use the pulse oximeter in a combustible environment(oxygen enriched environment). 11. Do not use the pulse oximeter outside the specified operating and storage temperature ranges. 12. Field strengths from fixed transmitters, such as base stations for radio(cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast towers and TV broadcast towers may affect accuracy. 13. The materials used in the pulse oximeter are conformed to the biocompatibility and nontoxic and no hazard to the body. 14. Use in emergency vehicles with communication systems may affect accuacy. 15. The packing material of the pulse oximeter is recyclable, and they must be collected and disposed according to the related regulation in the country or region where the package of the device or its accessories in opened. 16. Any material of the pulse oximeter that may cause pollution in the environment, must be collected disposed strictly compiled with the local rules and requirements. CHARGE THE BATTERY Plug the ihealth Pulse Oximeter PO3 into a USB port for three hours or until the battery indicator turns off. 4

USING YOUR PULSE OXIMETER 1. GET THE APPLICATION FOR PO3 The pulse oximeter works with an ipod, iphone, and ipad. You will first need to install the application(app). If you have not installed it yet, please proceed as follows to download the app. You can download the PO3 app from App Store using the process described below. Ensure that you have access to the internet. Launch the App Store and perform a search using the key words ihealth, PO3 to locate the app. Download the appropriate app and then install it. 2. USING WITH ios DEVICE STEP 1: Check that your ipod, iphone or ipad is listed under compatible models. STEP 2: Check that the ios is V5.0 or higher. if not, you may need to update your ios before using this product. STEP 3: Open Bluetooth on your ipod, iphone or ipad(setting->general->bluetooth->on). STEP 4: Launch the app and login, then the app should connect to the pulse oximeter, if connect successfully, the app should show the measuring page. NOTE: When you use app for the first time, you should create new user and input some personal information. STEP 5: Open the clamp and place your finger into the rubber opening of the pulse oximeter(your finger nail should touch the bottom portion), then releasing the clamp. STEP 6: Press the button on front panel to turn the pulse oximeter on. STEP 7: Keep your hands still for the reading. Do not shake your finger during the test. It is recommended that you do not move your body while taking a reading. STEP 8: After a few seconds, you can read the data on the app. STEP 9: When no signal or low signal is detected. the pulse oximeter will power off automatically in 8 seconds. 3. USING WITHOUT ios DEVICE After it has been used for the first time, the date and tme of the pulse oximeter will be synchronized with the ios device. The pulse oximeter can also be used 5

without being connected to an ios device. In this case, the measurement data is stored in memory and can be uploaded to an ipod, iphone or ipad when the connection is re-established. The pulse oximeter can store 100 measurements. When the memory is full, any new measurements overwrite the oldest ones. 4. OPERATION INSTRUCTIONS For detailed operating instructions, please visit http://www.ihealth99.com/ NOTE: The pulse oximeter is intended for use as a spot check device and should not be kept in place for an excessive period of time. Take care to check the positioning and sensitivity of the user during monitoring. CARE AND MAINTENANCE 1. Clean the device once per week, when doing the cleaning, carefully swab inside the device with a soft cloth or cotton swab with rubbing alcohol. Do not pour the alcohol directly on or into the device. 2. Do not drop this device or subject it to strong impact. 3. Avoid high temperature and solarization. Do not immerse the device in water as this will result in damage to the device. 4. If this device is stored near freezing, allow it to acclimate to room temperature before use. 5. Do not attempt to disassemble this device. 6. If you do not use the device for a long time, please remove the batteries. TROUBLESHOOTING Problem Possible Cause Solution 1. Finger may not plugged correctly 2. Finger may be trembling still SpO2 or pulse rate is shown unstable or no value The oximeter cannot be turned on Low Battery indication blinking The app can not find the pulse oximeter 1. low battery 2. The oximeter might be damaged Low battery 1. Retry by plugging the finger 2. Try to remain the finger 1. Charging the battery 2. Please contact with local customer service center Charging the battery Restart the Bluetooth; if still not successful, restart ipod, iphone or ipad 6

IMPORTANT INFORMATION REQUIRED BY THE FCC This device complies with Part 15 of the FCC Rules. Its operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. EXPLANATION OF SYMBOLS ON DEVICE Symbol for Caution Consult Accompanying Documents Symbol for Type BF Applied Part Symbol for no alarm for SpO2 SpO2% Oxygen Saturation bpm Pulse Rate(beats per minute) Low battery indicator Symbol for Disposal Procedure Symbol for Manufacturer 7

SERVICE CENTER ihealth Lab Inc. Mountain View, CA 94040 USA. 1-855-816-7705(Toll Free) www.ihealth99.com 8