User s Manual for Eclipse(AccuCap)

Similar documents
User s Manual for ProCAT

Florida Standards Assessments

SANAKO Lab 100 STS USER GUIDE

User Guide V: 3.0, August 2017

Sanako Lab 100 STS USER GUIDE

myphonak app User Guide

Table of Contents. Contour Diabetes App User Guide

Contour Diabetes app User Guide

Sleep Apnea Therapy Software Clinician Manual

TMWSuite. DAT Interactive interface

POST INSTALLATION STEPS FOR SHORETEL CONNECT, SHORETEL COMMUNICATOR AND FAQ

OneTouch Reveal Web Application. User Manual for Patients Instructions for Use

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

USER GUIDE: NEW CIR APP. Technician User Guide

Frequently asked questions to Oticon ConnectClip

6. If I already own another brand Videophone, can I use it with the ACN Digital Phone Service? No.

INSTRUCTOR WALKTHROUGH

Quick guide to connectivity and the ReSound Smart 3D app

Fully Automated IFA Processor LIS User Manual

Hanwell Instruments Ltd. Instruction Manual

Sleep Apnea Therapy Software User Manual

AudioConsole. User Guide. Doc. No EN/01 Part No EN

MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015

LiteLink mini USB. Diatransfer 2

mehealth for ADHD Parent Manual

Overview, page 1 Shortcut Keys for Cisco Unity Connection Administration, page 1 Other Unity Connection Features, page 4

Quick guide to connectivity and the Interton Sound app

Proteome Discoverer Version 1.3

See what they say with Captioned Telephone

Share/Follow. User Guide. A feature of Dexcom G5 Mobile CGM System

User Manual Verizon Wireless. All Rights Reserved. verizonwireless.com OM2260VW

Manual 2500E NRT Display Unit

RELEASED. Clearing your active insulin

Simple Caption Editor User Guide. May, 2017

Connectivity guide for. BeMore app

MedRx Video Otoscope Software

ShoreTel Trunk Side Integration Guide

THIM User Manual 1.0 GETTING STARTED 3 WHAT YOU LL FIND IN THE BOX 3

Clay Tablet Connector for hybris. User Guide. Version 1.5.0

CapTel 840. How-to Guide /17

EDUCATIONAL TECHNOLOGY MAKING AUDIO AND VIDEO ACCESSIBLE

Connectivity guide for ReSound Smart 3D app

Evolve 3 & 5 Service Manual

Beltone Solus Pro 1.9 Fitting Guide

Graphical User Interface for Windows for MCM Module

AVANT Audiometer Manual Rev. 2 Effective 10/05

BEMC/BSMD O.Tsai, 04/13/2006 Latest Update 01/30/2014

Entering HIV Testing Data into EvaluationWeb

ReSound LiNX Quattro fitting guide. A guide for professionals

Quick guide for Oticon Opn & Oticon ON App 1.8.0

Content Part 2 Users manual... 4

Desktop Fitting Guide for Phonak Brio 3

Elluminate and Accessibility: Receive, Respond, and Contribute

RELEASED. first steps. Icon Icon name What it means

Phonak RemoteControl App. User Guide

TRAINING MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

CapTel 800. How-to Guide /11

POLARPERSONALTRAINER.COM HELP

Iso-inertial dynamometer

ReSound Forte and ReSound Smart 3D App For Android Users Frequently Asked Questions

THERAPY MANAGEMENT SOFTWARE FOR DIABETES. User Guide

Quick guide for Oticon Opn & Oticon ON App 1.8.0

Manual Neon 2000 Family Neon Remote Terminals (NRT) 2017F Ethernet Family

Add_A_Class_with_Class_Number_Revised Thursday, March 18, 2010

VPAT Summary. VPAT Details. Section Telecommunications Products - Detail. Date: October 8, 2014 Name of Product: BladeCenter HS23

Connectivity guide for ReSound Smart 3D app

OneTouch Reveal Web Application. User Manual for Healthcare Professionals Instructions for Use

Diabetes Management App. Instruction Manual

Gocap System User s Guide

Thrive Hearing Control Application

Lionbridge Connector for Hybris. User Guide

User Manual. RaySafe i2 dose viewer

Cortex Gateway 2.0. Administrator Guide. September Document Version C

2.0. Desktop Fitting Guide getting started. Preparation of the hearing instruments

Use the following checklist to ensure that video captions are compliant with accessibility guidelines.

Avaya IP Office R9.1 Avaya one-x Portal Call Assistant Voluntary Product Accessibility Template (VPAT)

Avaya one-x Communicator for Mac OS X R2.0 Voluntary Product Accessibility Template (VPAT)

Phonak Target 4.3. Desktop Fitting Guide. Content. March 2016

USING THE MINIMED 670G SYSTEM. Instructions for the Experienced MiniMed 630G System User

Unit 1: Introduction to the Operating System, Computer Systems, and Networks 1.1 Define terminology Prepare a list of terms with definitions

Welcome! With a little effort you can have a big effect

TruLink Hearing Control App User Guide

Diabetes Management Software V1.3 USER S MANUAL

How to Demo Phonak Brio TM 3 R-C

Kinematic Rapid Assessment

Fitting System Instructions for Use

TruHearing app - Tinnitus Manager user guide

Quick guide for Oticon Opn & Oticon ON App

How to Use Own Voice Processing in Connexx 8. Rebecca Herbig, AuD

Agile Product Lifecycle Management for Process

Walkthrough

Relay Conference Captioning

Quick guide for Oticon Opn & Oticon ON App 1.8.0

GEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7

VPAT. Voluntary Product Accessibility Template. Version 1.3

Transcription:

InnoCaption Agent Program User s Manual for Eclipse(AccuCap) VER 2.1.4 InnoCaptionAgent Ver 2.1.4 2015-10-12 InnoCaption 1 / 24 InnoCaption Agent User s Manual for Eclipse

Table of Contents 1. GENERAL... 3 1.1. SCOPE OF THIS DOCUMENT... 3 1.2. ABBREVIATION... 3 2. INITIAL SETUP... 4 2.1. NETWORK CONFIGURATION... 4 2.2. PROGRAM INSTALLATION... 5 2.3. LOGIN PROCEDURE... 8 3. ESTABLISH CONNECTION WITH YOUR STENOGRAPHY SOFTWARE PROGRAM... 12 3.1. CONFIGURATION SETTINGS... 12 3.2. HOW TO USE ECLIPSE SOFTWARE PROGRAM WITH THE INNOCAPTIONAGENT PROGRAM... 16 4. CAPTIONING SERVICE PROCEDURE... 17 5. HOW TO HANDLE SPECIAL EVENTS... 19 5.1. 911 CALL... 19 5.2. MISUSE/ABUSE... 19 5.3. AUDIO/VOICE WITH NOISE... 19 5.4. NO AUDI/VOICE... 20 5.4.1. Unstable voice network connectivity of hearing user.... 20 5.4.2. Unstable data network(packet network) connectivity of InnoCaptionAgent program... 20 6. HANDOVER PROCEDURE... 21 7. INDICATION OF INNOCAPTIONAGENT PROGRAM... 23 7.1. CA LOGIN MODE... 23 7.2. CONNECTION WITH STENOGRAPHY... 23 7.3. INTERNET ENVIRONMENT... 24 7.3.1. Idle State (No Service State)... 24 7.3.2. In Service State... 24 Technical support: support@innocaption.com 2 / 24 InnoCaption Agent User s Manual for Eclipse

1. General 1.1. Scope of this Document This document specifies the manual of InnoCaption Agent program user. 1.2. Abbreviation CA CU WCTS WCTSS HO Captioning Agent Caption User Wireless Caption Telecommunication Serivce WCTS System Handover(Service transfer between CA and CA) 3 / 24 InnoCaption Agent User s Manual for Eclipse

2. Initial Setup 2.1. Network Configuration General user (Hearing Person) YOU (Captioning Agent) Stenography Stenography Software InnoCaptionAgent.exe IP Network Captioning user WCTSS For providing stable captioning service: CA s computer must be connected with High speed internet (for best performance, using T1 or E1) CA s computer must be connected with Ethernet cable (do not use Wi-Fi) CA must use wired headset or earphone for listening the voice.(usb or Bluetooth headset is not recommendable due to unstable connectivity) 4 / 24 InnoCaption Agent User s Manual for Eclipse

2.2. Program Installation Execute your web browser Connect to http://www.innocaption.com/download-agent/ Download the latest version of InnoCaptionAgent xxx.msi file Execute the install program 5 / 24 InnoCaption Agent User s Manual for Eclipse

Click the Next> button Click the Next> button 6 / 24 InnoCaption Agent User s Manual for Eclipse

Click Close button To execute the program, click Start > Program > InnoCaption > InnoCaption Agent or click the InnoCaption Agent shortcut icon on the desktop 7 / 24 InnoCaption Agent User s Manual for Eclipse

2.3. Login Procedure Execute the program Execute your Stenography software and connect with InnoCaptionAgent program using TCP/IP Note: Refer to Chapter 3. Establish Connection with your Stenography software program Enter your login ID & Password, click Login button. Note: Initial password will be given Special Log in Mode : This can be used for specific purpose as below; For Test/ Training Login as TEST mode using #(pound) key after Login ID Example: james# For providing a specialist captioning, such as medical, technology Login as SPECIALIST mode using *(star) key after Login ID Example: james* Note: CA who has logged in one of these modes will be excluded from call distribution. Once your login is accepted, the Server status will change into green color. 8 / 24 InnoCaption Agent User s Manual for Eclipse

NOTE 1: If the InnoCaption Agent program detects disconnection (red color as below) with Stenography software, it will exit automatically. NOTE 2: Name of the fields. (1) CA No. / Program Version (2) Call Answer Button (3) Handover Request/ Action Button (4) Queued Call Count / 911 Call Indicator (5) Number of logged in CAs/ Server Status (6) Stenography S/W Type (7) Call Progress Indicator (8) Button for TX Nose Voice to InnoCaption User (9) Button for TX No Voice InnoCaption User (10) Button for TX MISUSE to InnoCaption User (11) Handover Cancel Button (12) Text(Captioned Data) Viewer (13) Captioned Data TX Path Indicator (14) Captioned Data TX Indicator/ Keep Alive Indicator (15) Message Box(from Manager or Server) (16) Configuration Button (17) Exit Button 9 / 24 InnoCaption Agent User s Manual for Eclipse

Click the Config.. button to change login password and set the parameters. Parameter setting. Input Caption Data Format (TCP Port is 3321) : select Stenography software program you use o Eclipse o ProCAT o CaseCATalyst Ring Tone Volume : Set value as desired Change your password : Personalize login password o Enter login password, then choose new password and confirm Button Macro : You can personalize MACRO keys by any 3 letters that will work best for you 10 / 24 InnoCaption Agent User s Manual for Eclipse

o Noise: aaa sends the following message to the user caption screen. [Poor audio. Please ask to speak louder and clear] o No Voice: qqq sends the following message to the user caption screen [No audio. Please hang up and try again] Note) These 2 parameters notify the poor network conditions to the caption user during a call o Misuse: mmm send the following warning messages to the caption user phone 1 st Warning [Warning! Your call is suspected as misuse. By law, this service cannot be used for CART or in-person transcription. If yes, please hang up immediately.] 2 nd Warning [Warning! By law, this service cannot be used for CART or in-person transcription. Your call will be disconnected soon.] After 2 nd Warning, the call will be disconnected within 3 seconds Note) This parameter is to prevent a caption user from misuse. o Accept Captioning: Macro of eee from the stenography can be used to accept a call Note) Macro of eee has the same function as pressing Space Bar to answer the call. Etc. o The call status window will be hidden once a caption call is established. 11 / 24 InnoCaption Agent User s Manual for Eclipse

3. Establish Connection with your Stenography software program 3.1. Configuration Settings Click Settings button Make sure Realtime tab is active Change Flush. value to 500 ms Click Add.. button under Output formats Confirm that the following values listed below are set accordingly: Output format must be set to ANSI Comm device must be set to TCP/IP 12 / 24 InnoCaption Agent User s Manual for Eclipse

Click Setup>> button next in the Comm device selection Enter 127.0.0.1 in the edit box, then click the OK button. Enter 3321 in the next box, then click the OK button again. In the Output format dialog box, click the OK button 13 / 24 InnoCaption Agent User s Manual for Eclipse

Confirm that your dialog box has the values as shown below. Click Paragraphs tab, and set all of the values as below(all paragraph types) 14 / 24 InnoCaption Agent User s Manual for Eclipse

Click <<-- Copy button for saving under Master format Click Master format to save setting 15 / 24 InnoCaption Agent User s Manual for Eclipse

3.2. How to use Eclipse software program with the InnoCaptionAgent program Make Eclipse program ready to interconnect with InnoCaptionAgent program Confirm that Input InnoCaption Data Format is set to Eclipse in InnoCaption Agent Program Execute Eclipse for Realtime service Click Realtime button. Make sue connection state of InnoCaptionAgent program screen as shown below (Green color) Important Warning! Please do not attempt to correct or delete the captioned text by using mouse or back space during captioning service. If you do it, it may cause scrolling or trembling text on user s phone screen. 16 / 24 InnoCaption Agent User s Manual for Eclipse

4. Captioning service procedure When stenography is ready, the following screen is shown up(idle/disconnected state) When a caption user receives or places a call, the Progress window changes from Idle to Request Captioning in yellow flashing and Accept Captioning button is focused. At the same time, you will hear the Ring sound for awaiting acceptance. To accept captioning for this new call, you have three options; Press the Space Bar. or Use the macro of eee to Accept Captioning or Click Accept Captioning button of InnoCaption Agent program. Start captioning what is being heard immediately. NOTE: While captioned text is being displayed in the Text Viewer, the 1~5 box changes to green and the size of bubble in Text Path Status keep changing. NOTE: If any interfacing issue is occurred between the Stenography and InnoCaptionAgent program, some of the numeric boxes will stay in gray color. Then you need to report the number of grayed boxes to InnoCaption CA Manager. 17 / 24 InnoCaption Agent User s Manual for Eclipse

When a call is disconnected, progress window will gray out and return to an IDLE state. 18 / 24 InnoCaption Agent User s Manual for Eclipse

5. How to handle special events 5.1. 911 Call In the event that you are serving 911 call, 911 CALL in highlight will appear in InnoCaptionAgent program screen as below. As all 911 calls will be connected to ECRC (Emergency Call Relay Center) first and be routed to an appropriate PSAP (Public Service Answering Point), you would not be heard any audio while the call is being transferred. Please do not use No Voice or Noise or Misuse button and just wait. 5.2. Misuse/Abuse When misuse, such as CART or in-person transcription, is suspected during a caption call, please click Misuse button (or Macro key). Upon clicking the button, the 1 st warning message will appear on InnoCaption user s screen. If you believe misuse is continuing, click Misuse button again. Then, the 2 nd warning will appear on InnoCaption user s screen and the call will be disconnected automatically within three seconds. 1 st warning message : Warning! Your call is suspected as misuse. By law, this service cannot be used for CART or in-person transcription. If yes, please hang up immediately. 2 nd warning message : Warning! By law, this service cannot be used for CART or in-person transcription. Your call will be disconnected soon. 5.3. Audio/Voice with Noise When you cannot hear voice clearly due to noise, please click Noise button (or Macro key). Then, the below message will appear on InnoCaption user s screen. [Poor audio. Please ask to speak louder and clear] 19 / 24 InnoCaption Agent User s Manual for Eclipse

5.4. No Audi/Voice 5.4.1. Unstable voice network connectivity of hearing user. If you cannot hear any voice at all, please click No Voice button (or Macro key). Then, the below message will appear on InnoCaption user s screen. [No audio. Please hang up and try again] 5.4.2. Unstable data network(packet network) connectivity of InnoCaptionAgent program If Server status indicator is blicking in orange color or text trasmitting indicator in Text Path Status changes to red color, please make trouble shooting as below; 1 Click No Voice button. Upon a call being disconnected, please log out from InnoCaptionAgent program immediately. 2 Reboot your network modem and router. 3 Log in InnoCaptionAgent program with test mode(refer to chapter 2.3) 4 Confirm Server status indicator is green color. 5 If it dose not resolve the issue, your modem or router might have defects. Please contact your high speed internet provider to get consultation. 6 Once you confirm normal status, please log out from test mode and log in into normal mode. 7 Start service. 20 / 24 InnoCaption Agent User s Manual for Eclipse

6. Handover procedure This feature can be used for CA shift changes, emergencies and technical problems. If a CA s shift is approaching to the end during captioning a call, then the CA may use Handover Request feature. With this feature in place there is no need for the CA to stay longer than their shift requires unless they are asked by CA Operation manager.. With the Handover procedure in place, a CA can seamlessly transfer a call to another CA. If all CA s are busy, the request may not be taken place immediately until there is any CA available to caption. Before attempting handover a call, please make sure that there is a CA who can receive the handover procedure. NOTE: CA can start handover when the number of agent indicator displays more than 2. Upon clicking the Handover REQUEST button, the color of the button changes into yellow. The best time to do is when InnoCaption user is talking. This allows you to click the Handover REQUEST button at a captioning break. NOTE: If there is no CA available to receive the handover, the color of the button does not change. When the other CA takes the handover call, then the button changes into 'Handover ACTION' with green color. During transition, both CAs will hear the same conversation and should keep captioning simultaneously to make the seamless transition. Only the original CA s caption will be live until the Handover Action is complete. This allows the new CA to seamlessly jump into the call and get ready to caption without error. 21 / 24 InnoCaption Agent User s Manual for Eclipse

To complete the handover, the original CA clicks the Handover ACTION button when InnoCaption user starts talking. Then, new CA can start captioning when the hearing user starts talking back. NOTE: CA can cancel the handover procedure using click the 'Handover CANCEL'. When the handover is successful, the current call is released from the original CA automatically. 22 / 24 InnoCaption Agent User s Manual for Eclipse

7. Indication of InnoCaptionAgent Program 7.1. CA Login Mode Normal mode Test Mode Specialist Mode 7.2. Connection with Stenography Normal Disconnected with Stenography - Action of CA: Restart the stenography software program 23 / 24 InnoCaption Agent User s Manual for Eclipse

7.3. Internet Environment 7.3.1. Idle State (No Service State) Normal : Green color Keep alive failure with system : Orange color - Action of CA: Check internet connection 7.3.2. In Service State If captioning text data is reaching to the WCTS server, then the size of bubble keeps being changed. (Normal state) If Captioning text data is not reaching to WCTS server, then the size of bubble doesn't change If the indication box is in red color, it means there is no voice frame from the WCTS server. - Action of CA: Click No Voice button 24 / 24 InnoCaption Agent User s Manual for Eclipse