Case Report Inflammatory Pseudotumor Complicated by Recurrent Dislocations after Revision Total Hip Arthroplasty

Similar documents
Case Report Anterior Subluxation after Total Hip Replacement Confirmed by Radiographs: Report of Two Cases

Case Report Osteolysis of the Greater Trochanter Caused by a Foreign Body Granuloma Associated with the Ethibond Suture after Total Hip Arthroplasty

Bone Bangalore

Case Report Unusual Bilateral Rim Fracture in Femoroacetabular Impingement

Case Report Pediatric Transepiphyseal Seperation and Dislocation of the Femoral Head

Case Report Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

CASE 56 Hip Pain. ? Diagnosis

Case Report Anterior Hip Subluxation due to Lumbar Degenerative Kyphosis and Posterior Pelvic Tilt

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

Case Report A Case Report of Isolated Cuboid Nutcracker Fracture

TOTAL HIP REPLACEMENT:

*smith&nephew CONTOUR

Peggers Super Summaries: THR and Revision Concepts

Case Report Patellofemoral Joint Replacement and Nickel Allergy: An Unusual Presentation

Case Report Reverse Segond Fracture Associated with Anteromedial Tibial Rim and Tibial Attachment of Anterior Cruciate Ligament Avulsion Fractures

Adverse Local Tissue Reaction in Total Hip Replacement

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

COI. Consulting-TJO, United Institutional Support- Smith & Nephew, Acelity-KCI, Stryker, USMI

Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces

Optimum implant geometry

Case Report Medial Radial Head Dislocation Associated with a Proximal Olecranon Fracture: A Bado Type V?

Sven Märdian, Klaus-Dieter Schaser, Florian Wichlas, and Philipp Schwabe

Histological Features of Pseudotumor-like Tissues From Metal-on-Metal Hips

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Case Report Multiple Giant Cell Tumors of Tendon Sheath Found within a Single Digit of a 9-Year-Old

Case Report Successful Closed Reduction of a Lateral Elbow Dislocation

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

Femoral neck fracture during physical therapy following surface replacement arthroplasty: a preventable complication?

Duraloc CONSTRAINED LINER

Rx90 Total Hip System Acetabular Series

RECOVERY. P r o t r u s i o

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Hip dislocation after total hip arthroplasty can be classified

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

DIRECT ANTERIOR APPROACH

Dual Mobility Cups. Kris Govaers, MD, PhD Dendermonde Belgium

Product Information. *smith&nephew POLARCUP Dual Mobility System

Case Report Ipsilateral Hip Dysplasia in Patients with Sacral Hemiagenesis: A Report of Two Cases

Case Report Exactech Opteon Femoral Component Fracture 12 Years after Arthroplasty

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Case Report An Undescribed Monteggia Type 3 Equivalent Lesion: Lateral Dislocation of Radial Head with Both-Bone Forearm Fracture

Soft Tissue Imaging in. Total Hip Arthroplasty

Preoperative Planning. The primary objectives of preoperative planning are to:

Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ

Revision Total Hip Replacement

Original Date: December 2015 Page 1 of 8 FOR CMS (MEDICARE) MEMBERS ONLY

DURALOC. Acetabular Cup System. Surgical Technique

Baris Beytullah Koc, 1 Martijn Schotanus, 1 Bob Jong, 2 and Pieter Tilman Introduction. 2. Case Presentation

Research Article Relationship between Pain and Medial Meniscal Extrusion in Knee Osteoarthritis

Exam Corner. Hips and Knees. Prepared by Ahmed El-Bakoury, Asif Parkar and Mohamed Sukeik

Eisuke Nomura, Hisatada Hiraoka, and Hiroya Sakai. 1. Introduction. 2. Case Report

TOTAL KNEE ARTHROPLASTY (TKA)

Case Report Total Knee Arthroplasty in a Patient with Bilateral Congenital Dislocation of the Patella Treated with a Different Method in Each Knee

The Young Adult Hip: FAI. Jason Snibbe, M.D. Snibbe Orthopedics Team Physician, University of Southern California

Preventing complications in THR

Total Hip Arthroplasty Performed Using Conventional and Computer-Assisted, Tissue- Preserving Techniques 6

Scandinavian Journal of Surgery 103: 54 59, 2013

ACETABULAR CUP SURGICAL TECHNIQUE

Case Report A Case of Nonunion Avulsion Fracture of the Anterior Tibial Eminence

Design Rationale. ECHELON Primary Hip System

Hip Replacement - Anterior

Disclosure. Direct Anterior THA via Extension Table. History 11/3/2015

Mid Term Results of Total Hip Arthroplasty for Various Hip Disorders

DIRECT ANTERIOR APPROACH. Guide for use with the Furlong Evolution Femoral Stem & CSF Plus Acetabular Cup

Total Hip Replacement in Diaphyseal Aclasis: A Case Report

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

Imaging features of complications following hip replacement: A pictorial assay

The Birmingham Interlocking Pelvic Osteotomy (BIPO) for Acetabular Dysplasia: 13 to 21 Year Survival Outcomes

Degenerative arthritis of Hip Bone Bangalore. Prof Sharath Rao Head, Dept. of Orthopaedics KMC Manipal

Case Report Massive Femoral Osteolysis Secondary to Loosening of a Cemented Roughened Long Stem: A Case Report

DISLOCATION OF THE TOTAL HIP Arthroplasty

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe

Manza Cup HA SURGICAL TECHNIQUE.

The Leader in Orthopaedic Innovation

Case Report Double-Layered Lateral Meniscus in an 8-Year-Old Child: Report of a Rare Case

Case Report Arthroscopic Bony Bankart Repair Using Double-Threaded Headless Screw: A Case Report

Transverse Acetabular Ligament A Guide Toacetabular Component Anteversion

Optimum implant geometry

The development of alternate bearing surfaces in total

The Treatment of Pelvic Discontinuity During Acetabular Revision

TaperFit. Cemented Total Hip Replacement Surgical technique

Recently, the new generation of metal-on-metal total hip resurfacing. arthroplasty is well known for preserving the proximal femoral bone stock,

Informed Consent for HRA

Kanji Mori, Kazuya Nishizawa, Akira Nakamura, and Shinji Imai. 1. Introduction. 2. Case Presentation

Pseudotumours associated with metal-onmetal hip resurfacings

Burwood Road, Concord 160 Belmore Road, Randwick

Zimmer MIS Mini-Incision THA Anterolateral Approach

Hip Biomechanics and Osteotomies

OUTCOMES AFTER REVISION OF METAL-ON-METAL HIP RESURFACING ARTHROPLASTY THOMAS P. GROSS, MD FEI LIU, PHD MIDLANDS ORTHOPAEDICS, P.A.

Minimally Invasive System for Total Hip Arthroplasty. Surgical Technique

Case Report Double-Layered Lateral Meniscus Accompanied by Meniscocapsular Separation

Metal Ion Levels Not Sufficient as a Screening Measure for Adverse Reactions in Metal-on- Metal Hip Arthroplasties

Stability without compromise. Epsilon Durasul Constrained Insert

Case Report A Rare Case of Traumatic Bilateral Fibular Head Fractures

Hip Resurfacing.

Good sensitivity and specificity of ultrasound for detecting pseudotumors in 83 failed metal-on-metal hip replacements

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

MRI Findings in Painful Metal-on- Metal Hip Arthroplasty

Case Report Denosumab Chemotherapy for Recurrent Giant-Cell Tumor of Bone: A Case Report of Neoadjuvant Use Enabling Complete Surgical Resection

Transcription:

Case Reports in Orthopedics, Article ID 792781, 5 pages http://dx.doi.org/10.1155/2014/792781 Case Report Inflammatory Pseudotumor Complicated by Recurrent Dislocations after Revision Total Hip Arthroplasty John Ryan Quinn, Jason Lee, and Ran Schwarzkopf Department of Orthopaedics, Joint Replacement Surgery, University of California, Irvine, 101 The City Drive South, Pavilion III, Building 29A, Orange, CA 92868, USA Correspondence should be addressed to Ran Schwarzkopf; schwarzk@gmail.com Received 16 January 2014; Revised 1 July 2014; Accepted 8 July 2014; Published 4 August 2014 Academic Editor: Wolfram Steens Copyright 2014 John Ryan Quinn et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. A 71-year-old female with a history of right total hip arthroplasty presented with an enlarging pseudotumor. Pseudotumor is a known complication following metal-on-metal and metal-on-conventional polyethylene and metal-on-highly cross-linked polyethylene implants. Revision total hip arthroplasty following resection of pseudotumor has resulted in an increase in incidence of postoperative complications. Despite stable implants, these complications arise from the amount of soft tissue damage combined with the loss of tissue support around the resected hip. Our case is a clear example of a major complication, recurrent dislocation, following resection and revision surgery. 1. Introduction Periprosthetic inflammatory masses or cysts are rare yet known complications of total hip arthroplasty (THA). They are commonly referred to as inflammatory pseudotumors [1]. The inflammatory component is derived from histological findings, which include periarticular tissue necrosis and perivascular lymphocytic inflammation also known as aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) [2 6]. The recent revival of second-generation metal-on-metal (MoM) hip replacements, due to decreased wear rates, has been associated with the development of these inflammatory pseudotumors [7 9]. They have also been reported after metal-on-conventional polyethylene bearing THA [10 15]. A recent report showed formation of a pseudotumor with metal-on-highly cross-linked polyethylene bearing THA [16]. Pseudotumors cause a spectrum of clinical problems, ranging from an asymptomatic lesion to a large mass causing significant symptoms: pain, discomfort, or nerve palsy [17]. Resection of these pseudotumors is difficult and can lead to an increase in complication rates following revision total hip arthroplasty surgery. The recommendation for pseudotumor resection is to remove as early as possible in order to limit the amount of soft tissue damage [18, 19]. We present a severe, complex case, where the resection and revision THA resulted in significant anterior soft tissue damage and tissue loss leading to anterior instability facilitating recurrent dislocation. 2. Case Report A 71-year-old female with a history of right THA in 1975, as well as a right total knee arthroplasty in 1992, presented to clinic with a chief complaint of an enlarging right hip soft tissue mass (Figure 1). The mass was initially noted 6 months previously and was evaluated at an outside clinic by MRI. The MRI revealed a 12.0 12.1 14.3 cm multilobulated soft tissue mass of the right hip region (Figure 2). She denied any pain, discomfort, paresthesia, or weakness. Her previous THA consisted of an old Charnley cemented components. Physical examination of the right hemipelvis and lower extremity revealed a firm, immobile, nontender mass measuring around 14.0 12.0 cm. Range of motion of the right hip was noted at 50 degrees of flexion, 5 degrees of internal rotation, 15 degrees of external rotation, and limited abduction. There was a difference in leg lengths on exam with the left leg being 1 cm shorter than the right.

2 Case Reports in Orthopedics Figure 1: AP radiograph of pelvis revealing previous right total hip arthroplasty. Figure 3: CT scan showing the mass originating from the right hip joint and extending predominantly anteriorly and medially. Figure 2: MRI showing 12.0 12.1 14.3 cm multilobulated soft tissue mass. Lab work was significant for an elevation of ESR and CRP at 46 mm/hr (ESR < 30 mm/hr) and 5.9 mg/dl (CRP < 0.7 mg/dl), respectively. White blood cell count was within normal limits. Radiographic images revealed signs of both acetabular and femoral loosening with previous wires from a greater trochanter osteotomy. The radiograph also revealed decreased bone mineralization and severe osteolysis especially in the proximal femur with complete resorption of the greater trochanter. CT scan with contrast showed a 15.0 7.5 9.6 cm mass originating from the right hip joint and extending predominantly anteriorly and medially with mass effect (Figure 3). Core needle biopsy showed no malignant cells. It consisted of mostly blood and fragments of fibrous tissue, most commonly associated with pseudotumor. The diagnosis of pseudotumor resulted in resection with right revision THA. A multispecialty team comprised of a fellowship trained orthopaedic tumor surgeon and an adult reconstruction fellowship trained orthopaedic surgeon performed the surgery. A direct anterior approach was utilized due to the location of the tumor and the patient s previous Figure 4: Pseudotumor status after resection. scar, and the incision was taken down through the scar tissue and the fascia. The tumor was located bulging through the tensor fascia lata, and the capsule was dissected circumferentially. It was tracked down through the superior pubic ramus and down toward the ischium. The tumor was removed all the way down to the anterior rim of the acetabulum leaving a large gap between skin and acetabulum (Figures 4 and 5). The subsequent procedure, revision THA, was warranted secondary to the severe osteolysis from polyethylene wear and aseptic loosening of the femoral component. After resection of the tumor, inspection of the acetabulum showed a loosened acetabular shell with significant anterior wall and anterior column bone loss. The acetabulum was revised and a trabecular metal revision shell (Trabecular Metal Acetabulum Revision System; Zimmer, Warsaw, IN) was press fit in a position of maximum bony contact and secured with multiple screws. A highly cross-linked polyethylene liner was cemented in 45 degrees of abduction and 20 degrees of anteversion. The stem was removed from the cement mantle without difficulty. Due to the low bone quality, the previous cement mantle, and the location of the total knee

Case Reports in Orthopedics 3 Figure 5: Gross image of the dissected pseudotumor. Figure 6: Revision total hip arthroplasty complicated by anterior dislocation. femoral stem, it was decided that the only feasible option to secure a new femoral implant would be to cement a new femoral stem into the existing cement mantle. Due to the instability anteriorly during trial reduction, the stem was cemented in neutral version (Synergy; Smith and Nephew, Memphis, TN). The hip had good range of motion with flexion to 100 degrees and flexion to 90 degrees with more than 80 degrees internal rotation. Impingement was noted on extreme extension, external rotation, and adduction, but it was determined that the patient would not achieve this extreme range of motion. Radiographic evaluation in the recovery room showed an acute hip dislocation (Figure 6). Her immediate postoperative care was complicated by anterior dislocation. Her impingement of the femoral neck implant on the posterior aspect of the acetabular cup resulted in dislocation due to lack of any anterior soft tissue restraint. The patient returned to the operating room and the dislocated joint was visualized. It was decided to revise the cemented acetabular liner and place it in 45 degrees abduction and neutral version. Her range of motion was tested again and she was found to be stable in extension, external rotation, and adduction as well as flexion greater than 100 degrees and flexion of 90 degrees with 80-degree internal rotation. Postoperative radiographs were taken to verify position of the components (Figure 7). Follow-up two and a half weeks later revealed recurrent dislocation. She was taken to the emergency department where closed reduction was attempted unsuccessfully. The patient was taken to the OR where again the significant anterior soft tissue loss was noted facilitating anterior dislocation. It was decided to place a constrained liner to prevent further dislocation. Range of motion was tested and her hip was stable (Figure 8). At the 3-month follow-up the patient was doing well and radiographic images revealed a stable implant (Figure 9). She continues to progress and is currently full weight bearing with no pain. Follow-up radiographs continue to reveal a stable implant (Figures 10 and 11). Figure 7: Postoperative radiograph status after reduction of dislocated hip. Figure 8: Re-revision surgery status after constrained liner.

4 Case Reports in Orthopedics Figure 9: 3 months after operation. Figure 11: 8 months after operation. 3. Discussion Figure 10: 5 months after operation. Inflammatory pseudotumors have complicated all bearings of THA including MoM, metal-on-conventional polyethylene, and metal-on-highly cross-linked polyethylene [10 16]. The reported incidence rate of pseudotumor formation in MoM by Pandit et al. is one percent of THAs within 5 years [16]. No incidence rates for the other bearings have been reported in theliterature.thissamegroupcalculatedtherateofrevision during pseudotumor resection focusing on specific risk factors: age, gender, unilateral/bilateral THA, components, and histological features. They concluded that revision rate for pseudotumors in men under 40 years at 8 years was 0.5 percent compared to women with a rate of 13.1 percent at 6 years [16, 17]. They identified four specific risk factors that were associated with an increase in revision rate: female gender, age under 40, small components (<46mm in females, <50 mm in males), and dysplasia [17]. Female gender, age under 40, small components, and dysplasia increase the failure rate by 8.2, 3.3, 6.6, and 3 times, respectively [17]. Other studies have reported revision rates as high as 25 percent in women under 40 years of age and 5 percent in women over 40 years [16]. Our patient had all risk factors at the time of revision surgery: female, under 40 years when she received THA, smaller components (<46 mm for female), and demonstrated dysplasia. She was at a high risk of revision after pseudotumor resection. The outcome of revision surgery for pseudotumor is considerably worse than the outcome of other THAs [18]. Grammatopoulos et al. described a major complication rate of 50 percent after revision surgery following pseudotumor resection related to hip resurfacing [18]. The major complication rate of 50 percent is considerably higher than the rate of 14 percent after revision for other causes [18]. This study identified 53 hips that had undergone MoM hip resurfacing that required revision. Of these revised, 16 were due to pseudotumor. These surgeries tended to be more complexsecondarytothesofttissuedestruction.ofthe16hip revisions, 12 required blood transfusion postoperatively, and 8 experienced major complications [18]. Three of the revision hips experienced femoral nerve palsy, two had loosening of the acetabular component within two years, and three dealt with dislocation, two of which were recurrent [18]. All of these dislocations required femoral and acetabular component revision. Of interest, three out of the five recorded that underwent re-revision had evidence of recurrence of pseudotumor [18]. This study also illustrated the complexity of pseudotumor revision cases by measuring operating room time,functionaloutcomebytheoxfordhipscore(ohs),and the amount of activity by the University of California Los Angeles (UCLA) activity score [18]. Pseudotumor revisions showed a drastically increased operating room time, OHS scorewassignificantlyworseinpseudotumorrevisions(20.9 versus 40.2 and 37.8 in other groups), and UCLA activity score revealed a drop in activity [18]. Again, the outcome of revision for pseudotumor is poor. In fact, one-third of the patients undergoing revision for pseudotumor will have future rerevision surgeries [18]. Our case was a clear example of the complexity of pseudotumor revision. Revision surgery was complicated by recurrent dislocation requiring re-revision surgery with a constrained acetabular liner being placed. Our patient s surgery resulted in a loss of anterior capsule

Case Reports in Orthopedics 5 and musculature limiting her anterior physical stability to basically skin. This large gap was an enormous loss of stability. A constrained liner was placed to provide anterior stability decreasing her risk of dislocation. Aggressive early intervention is warranted in pseudotumor cases in order to decrease the amount of soft tissue loss leading to better outcomes. It is imperative to consider the risk factors associated with an increased rate of revision as early intervention may provide a more stable hip. Our case further supports the research done by Glyn-Jones et al. as she had all risk factors associated withahigherriskofrevision[17]. Our case was complicated not only by pseudotumor, complete resorption of the greater trochanter, and soft tissue loss but also by a previous total knee arthroplasty limiting our stem selection. The treatment options were limited, and ultimately a constrained liner was placed. Another feasible treatment option is covering the large defect anterior to the capsule with a transverse rectus abdominis pedicle flap [18]. The flap could be placed over the anterior capsule providing that anterior stability needed to prevent complications such as recurrent dislocation. This treatment option could have benefitted our patient because the pseudotumor resection left a limited barrier of only skin and small musculature fibers over the anterior portion of her hip joint. The outcome of such surgery has never been reported and would need further verification of the success rate. Overall, pseudotumor resection and revision THA is a complicated case with an increased incidence of postoperative complications. It is important to recognize patients that are at an increased risk of revision after pseudotumor resection because early aggressive intervention can be beneficial. If a large amount of soft tissue is destroyed or lost, then aggressive treatment options such as a constrained liner or flap could be utilized to try to decrease the fifty percent major complication rate or 33 percent re-revision surgeries required. Conflict of Interests The authors declare that there is no conflict of interests regarding the publication of this paper. References [1] H. Pandit, S. Glyn-Jones, P. McLardy-Smith et al., Pseudotumours associated with metal-on-metal hip resurfacings, Journal of Bone and Joint Surgery,vol.90,no.7,pp.847 851,2008. [2] P. Campbell, E. Ebramzadeh, S. Nelson, K. Takamura, K. de Smet, and H. C. Amstutz, Histological features of pseudotumor-like tissues from metal-on-metal hips, Clinical Orthopaedics and Related Research,vol.468,no.9,pp.2321 2327,2010. [3] A.P.Davies,H.G.Willert,P.A.Campbell,I.D.Learmonth,and C. P. Case, An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements, Bone and Joint Surgery A, vol. 87, no. 1, pp. 18 27, 2005. [4] F.S.Haddad,R.R.Thakrar,A.J.Hartetal., Metal-on-metal bearings: the evidence so far, Bone and Joint Surgery B, vol. 93, no. 5, pp. 572 579, 2011. [5] D.J.Langton,T.J.Joyce,S.S.Jamesonetal., Adversereaction to metal debris following hip resurfacing: The influence of component type, orientation and volumetric wear, Bone and Joint Surgery B, vol. 93, no. 2, pp. 164 171, 2011. [6] G.Mahendra,H.Pandit,K.Kliskey,D.Murray,H.S.Gill,andN. Athanasou, Necrotic and inflammatory changes in metal-onmetal resurfacing hip arthroplasties: relation to implant failure and pseudotumor formation, Acta Orthopaedica, vol. 80, no. 6, pp. 653 659, 2009. [7] F. W. Gruber, A. Böck, S. Trattnig, F. Lintner, and P. Ritschl, Cystic lesion of the groin due to metallosis : a rare long-term complication of metal-on-metal total hip arthroplasty, The Arthroplasty,vol.22,no.6,pp.923 927,2007. [8] A. J. Hart, S. Sabah, J. Henckel et al., The painful metal-onmetal hip resurfacing, Bone and Joint Surgery B, vol. 91, no. 6, pp. 738 744, 2009. [9]M.M.Mikhael,A.D.Hanssen,andR.J.Sierra, Failureof metal-on-metal total hip arthroplasty mimicking hip infection: areportoftwocases, Bone and Joint Surgery A,vol. 91,no.2,pp.443 446,2009. [10] T. Hananouchi, M. Saito, N. Nakamura, T. Yamamoto, and K. Yonenobu, Huge pelvic mass secondary to wear debris causing ureteral obstruction, Arthroplasty, vol.20,no.7,pp. 946 949, 2005. [11] W. Leigh, P. O Grady, E. M. Lawson, N. A. Hung, J. Theis, and J. Matheson, Pelvic pseudotumor : an unusual presentation of an extra-articular granuloma in a well-fixed total hip arthroplasty, Arthroplasty,vol.23,no.6,pp.934 938,2008. [12] K. H. Lin and N. N. Lo, Failure of polyethylene in total hip arthroplasty presenting as a pelvic mass, Arthroplasty,vol.24,no.7,pp.1144.e13 1144.e15,2009. [13] K.H.Mak,T.K.Wong,andN.C.Poddar, Weardebrisfrom total hip arthroplasty presenting as an intrapelvic mass, Journal of Arthroplasty, vol. 16, no. 5, pp. 674 676, 2001. [14] O. Svensson, E. B. Mathiesen, F. P. Reinholt, and G. Blomgren, Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report, Bone and Joint Surgery A, vol. 70, no. 8, pp. 1238 1242, 1988. [15] J.WangandC.Lin, Pelvicmasscausedbypolyethylenewear after uncemented total hip arthroplasty, Arthroplasty, vol. 11, no. 5, pp. 626 628, 1996. [16] H.Pandit,A.Walsh,N.Vassilios,andJ.Antoniou, Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty, TheJournalofAthroplasty, vol. 27, no. 2, pp. 324.e5 324.e8, 2012. [17]S.Glyn-Jones,H.Pandit,Y.Kwon,H.Doll,H.S.Gill,and D. W. Murray, Risk factors for inflammatory pseudotumour formation following hip resurfacing, Bone and Joint Surgery B,vol.91,no.12,pp.1566 1574,2009. [18] G. Grammatopoulos, H. Pandit, Y.-M. Kwon et al., Hip resurfacings revised for inflammatory pseudotumour have a poor outcome, Bone and Joint Surgery B, vol. 91, no. 8, pp. 1019 1024, 2009. [19]P.Harvie,H.Giele,C.Fangetal., Thetreatmentoffemoral neuropathy due to pseudotumour caused by metal-on-metal resurfacing arthroplasty, HIP International, vol. 18, no. 4, pp. 313 320, 2008.

MEDIATORS of INFLAMMATION The Scientific World Journal Gastroenterology Research and Practice Diabetes Research International Endocrinology Immunology Research Disease Markers Submit your manuscripts at BioMed Research International PPAR Research Obesity Ophthalmology Evidence-Based Complementary and Alternative Medicine Stem Cells International Oncology Parkinson s Disease Computational and Mathematical Methods in Medicine AIDS Behavioural Neurology Research and Treatment Oxidative Medicine and Cellular Longevity