CLINICAL CHEMISTRY REAGENTS. Product Profile

Similar documents
TRACEABILITY and UNCERTAINTY

TRACEABILITY and UNCERTAINTY

Manufacturer Report for Siemens Unassayed Chemistry Lot Exp 30 Jun 2018

Roche/Hitachi - PreciControl ClinChem Multi 2

CALIBRATION SERUM LEVEL 3 (CAL 3)

CALIBRATION SERUM - LEVEL 2 (CAL 2)

CALIBRATION SERUM LEVEL 3 (CAL 3)

Testing Kits. Pregnancy Test Kits. Hepatitis Test Kits. HIV - 1 & 2 Test Kits

short catalogue diasys diagnostic systems clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents

HUMAN ASSAYED MULTI-SERA - LEVEL 2 (HUM ASY CONTROL 2)

LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS - LEVEL 1 (LIQ CHEM ASY PREMIUM PLUS 1)

HUMAN ASSAYED MULTI-SERA - LEVEL 3 (HUM ASY CONTROL 3)

HUMAN ASSAYED MULTI-SERA - LEVEL 2 (HUM ASY CONTROL 2)

HUMAN ASSAYED MULTI-SERA - LEVEL 2 (HUM ASY CONTROL 2)

Clinical Chemistry Reagents Brochure

Clinical Chemisty Reagents Brochure. ekfdiagnostics.com STANBIOChemistry from EKF Diagnostics. Central Laboratory

Comparison of VACUETTE Heparin Gel Tubes for Common Chemistry Analytes

Chemistry Reference Ranges and Critical Values

Chemistry Reference Ranges and Critical Values

Thermo Scientific Konelab System Reagents For convenient and reliable analysis

Thermo Scientific System Reagents Excellence in Clinical Chemistry

Serodos and Serodos plus

COBAS INTEGRA / cobas c C.f.a.s.

Optimized for best performance in clinical chemistry testing

DEDICATED LINES LÍNEAS DEDICADAS

Excellence and confidence

PRODUCTS FOR EXPORT 2018

Stability of VACUETTE Lithium Heparin Separator tubes with modified centrifugation conditions

short catalogue clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents instruments Probedruck ::018 ::016

INDEX PAG CLINICAL CHEMISTRY Enzymes, Substrate, Electrolytes... PAG. 5 - CALIBRATORS CONTROLS... PAG. 6 - ELECTROPHORESIS. PAG.

TRACEABILITY and UNCERTAINTY 7

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Uni-Asia Scientific Instrument Company Limited. Stanbio Laboratory Product List

REAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Bureau of Laboratory Quality Standards Page 1 of 13

TRACEABILITY and UNCERTAINTY 9

MATERIAL AND METHODS

ASSAYED URINE CONTROL - LEVEL 2 (URN ASY CONTROL 2)

Evaluation of VACUETTE Urine CCM tube for Clinical Chemistry

QUALITROL 2H Insert. 01 Inglês - Ref.: 72. Ref.:72. Precautions and warnings

1. Calibra - H - Store at 2-8 ºC.

ASSAYED URINE CONTROL - LEVEL 3 (URN ASY CONTROL 3)

Evaluation of Cheongmeak DCS TM Reagents for Chemistry Analyzers

Controls & Calibrators Clinical Chemistry

Evaluation of VACUETTE CAT Serum Fast Separator Blood Collection Tube for Routine Chemistry Analytes in Comparison to VACUTAINER RST Tube

ENROLLMENT CONFIRMATION

VITROS MicroSlide Assay Summary

Tables of Normal Values (As of February 2005)

TABLE OF CONTENTS GENERAL INFORMATION... 1

NABL Deportment of Science E Technologv, lndiq

The Advanced, Fifth Generation SQA

ROTUNDA HOSPITAL DEPARTMENT OF LABORATORY MEDICINE

Contents. Section 1: Basic Laboratory Principles. 1. Laboratory Equipments, Glassware, Laboratory Hazards and General Laboratory Rules...

CTAD as a universal anticoagulant

Laboratory Medicine Standardization Activity in Japan

Heflotron" Plus - An enviable asset

General Chemistry Scheme Guide

Annex to the Accreditation Certificate D-ML according to ISO 15189:2012

BS-230. Clinical Chemistry Analyzer

M.D.IPA, M.D.IPA Preferred, Optimum Choice and Optimum Choice Preferred STAT Laboratory List Revised Jan. 5, 2017

Biochemistry Adult Reference Ranges

BIOO LIFE SCIENCE PRODUCTS

Inspector's Accreditation Unit Activity Menu

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Evaluation of new MiniCollect Z Serum (Separator) Tubes

Reagents. Reagents. ApTT. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT Cu. ApTT Cu Hp MAU D3-HB CHE L

Date... Name... Group... Urine sample (Tube No 2)

Evaluation Report of the Pneumatic Tube Transport System (PEVCO) connecting Dialysis Hospital to. Mubarak Hospital. Dr.

I Imhotep Diagnostics

Evidence Based Commutability: Bias 2 Study. Janice Gill Manager RCPAQAP Chemical Pathology Adelaide SA

NORMAL LABORATORY VALUES FOR CHILDREN

BIOCHEMICAL REPORT. Parameters Unit Finding Normal Value. Lipase U/L Amylase U/L

ICL Integrative Laboratory Services Test Menu Contact ICL Client Care x300

The highest quality range of routine and novel reagents REAGENTS

Delta Check Calculation Guide

Analyte Specimen Demographic Reference Range Units

Supplementary materials

Original paper. The effect of storage time and freeze-thaw cycles on the stability of serum samples. Introduction

Specimen Collection Requirements

CERTIFICATE OF CONFORMITY

Seeing is not Believing (13-Nov-2004)

Specimen Collection Requirements

Reagents. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT C ApTT Cu Hp MAU D3-HB CHE L. ApTT Cu Hp

Effect of Storage Time and Temperature on Serum Analytes

BASIC METABOLIC PANEL

Setting of quality standards

CERTIFICATE OF ACCREDITATION

MATERIAL AND METHODS. Material and Methods. 3.1 Source of data

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with:

Supplementary Table 1. Criteria for selection of normal control individuals among healthy volunteers

PRICE LIST RELIABLE ACCURATE COST EFFECTIVE. American Technology Made in India For India. W.E.F April 2018

VetScan Mammalian Liver Profile

Ascend Clinical Reference Ranges (November 2018) Chemistry

Ascend Clinical Reference Ranges (July 2018) Chemistry

Clinician Blood Panel Results

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Transcription:

Product Profile

Why Clinical Chemistry Reagents? Quantitative determination of specific analytes associated with various types of disease. Diagnosis Identifying a disease already present Prognosis Forecasting the possibility of getting a disease Screening - Mass testing Steps involved Assay procedure Data Interpretation Interpretation of test data Compare results with normal range Check the significant change from previous results α Amylase (LS) Methodology: kinetic method using α-napthylphosphate. Kit provided with Diluent (ACP), Diluent (Non prostatic ACP) and substrate. Sample volume : 0.1 ml semi automated and automated Stability of working Solution: 7-8 days at 2 8 ⁰ C Storage : 2-8 ⁰ C AC01 8 ml 8x1ml AC02 50 ml 10x5 ml ALBUMIN (LS) Determination of amylase activity in human serum or plasma. Methodology: kinetic method using Gal G 2 α CNP α - Amylase is a single reagent system. Sample volume : 0.05 ml semi automated and automated 8 ⁰ C Storage : 2 8 ⁰ C Reagent for determining Albumin in plasma or serum. Methodology: BCG method. Kit includes BCG Reagent & standard albumin-5gm/dl. Sample volume : 0.01 ml semi automated and Automated analyzer Stability of working Solution: Till Expiry at 2 Shelf life: 18 months Storage: 2 8 ⁰ C AM01 8 ml 8x1ml AM02 60 ml 2x30 ml ACID PHOSPHATASE Determination of acid phosphatase in human serum or plasma. AB01 50 ml 1x50 ml AB02 100 ml 2x50 ml AB03 200 ml 2x100 ml AB04 250 ml 5x50 ml AB05 1000 ml 2x500 ml Product Profile Page 2

ALKALINE PHOSPHATASE BILIRUBIN DIRECT (LS) Reagent for determining alkaline phosphatase in Methodology: kinetic method using p-nitro phenyl phosphate (p-npp). Kit provided with a diluent solution and substrate p-npp tablet. Sample volume : 0.02 ml semi automated and Automated Stability of working Solution: 21 days at 2-8 Shelf life :18 months Storage : 2 8 ⁰ C Reagent for determining direct Bilirubin in Methodology: Jendrassik & Grof. Method using Diazotized sulphanilic acid Kit provided with Billirubin direct reagent (D1) and (D2) Sample volume : 0.05 ml Instrument: Colorimeter, spectrophotometer, discrete semi automated and automated Stability of working Solution: 2 days at 2-8 Storage 2-8 AP01 50 ml 5x10 ml AP02 150 ml 15x10 ml BILIRUBIN TOTAL (LS) Reagents for determination of total Bilirubin in plasma or serum Methodology: Jendrassik & Grof. Method using Diazotized sulphanilic acid with DMSO. Kit provided with Bilirubin total reagent (T1) and (T2) Ready to use Sample volume : 0.05 ml Stability of working Solution: 2 days at 2-8 Storage: 2-8 ⁰ C DB01 200 ml 2x100 ml DB02 1000 ml 2x500 ml BILIRUBIN TOTAL & DIRECT (LS) Reagent for determining total and direct Bilirubin in Methodology: Jendrassik & Grof. Method using Diazotized sulphanilic acid with DMSO. Kit provided with Bilirubin Total Reagent (T 1) and (T 2), Bilirubin Direct Reagent (D1) and (D 2). Sample volume : 0.05 ml Stability of working Solution: 2 days at 2-8 Storage: 2 8 ⁰ C TB01 200 ml 2x100 ml TB02 1000 ml 2x500 ml BI01 100 ml 2X50 ml BI02 200 ml 2x100 ml Product Profile Page 3

CALCIUM (LS) Reagent for determination of calcium in Methodology: O Cresolphthalein Complexone ( CPC) Kit provided with CPC reagent, diluent reagent and standard calcium (10mg/dl). Sample volume : 0.02 ml Stability of working Solution: 7 days at 2-8 Storage : 2-8 ⁰ C CA01 50 ml R 1 1x25 ml R 2 1x25 ml CA02 100 ml R 1 1x50 ml R 2 1x50 ml CA03 200 ml R 1 1x100 ml R 2 1x100 ml CALCIUM ARSINAZO (LS) Reagent for determination total calcium concentration in serum Methodology: Colorimetric method using Arsenazo III Calcium Arsinazo is ready to use, single liquid reagent system. Sample volume: Stability of working Solution: Till expiry at room temperature Storage: 2-8 ⁰ C AS01 50 ml 1x50 ml AS02 100 ml 2x50 ml CHLORIDE (LS) Reagent for determination of chloride in Methodology: Mercuric thiocynate method. Kit provided with chloride reagent, standard chloride (100mMol/L). Sample volume : 0.02 ml semi automated and Automated Storage : 2-8 ⁰ C CL01 50 ml 1x50 ml CL02 100 ml 2x50 ml CHOLESTEROL (LS) Reagent for determining total cholesterol in Methodology: Cholesterol oxidase (CHOD) Peroxidase (POD) Kit provided with Cholesterol enzyme reagent and standard cholesterol (200mg/dl). Discrete semi automated and automated Product Profile Page 4

CH01 50 ml 1x50 ml CH02 125 ml 5x25 ml CH03 200 ml 2x100 ml CH04 250 ml 5x50 ml CH05 500 ml 5x100 ml CH06 1000 ml 2x500 ml CREATININE (LS) Reagent for determining creatinine in plasma or serum. Methodology: Jaffe(initial rate) using alkaline picrate. Kit provided with Picrate reagent, diluent reagent and standard Creatinine (2mg/dl). semi automated and Automated Stability of working Solution: 30 days at 2 8 CR01 50 ml R 1 1x25 ml R 2 1x25 ml CR02 100 ml R 1 1x50 ml R 2 1x50 ml CR03 200 ml R 1 1x100 ml R 2 1x100 ml CR04 1000 ml R 1 1x500 ml R 2 1x500 ml Gamma (GT) Reagent for determining gamma glutamylrasferase (GGT) in Methodology: IFCC Method. Kit provided with reagent R 1 and R 2. semi automated and automated Stability of working Solution: 60 days at 2 8 Storage: 2 GA01 10 ml R 1 1x8 ml R 2 1x2 ml GA02 50 ml R 1 1x40 ml GA03 100 ml R 1 2x40 ml GA04 200 ml R 1 2x80 ml R 2 2x20 ml GLUCOSE (LS) Reagent for determining true glucose in Methodology: GOD POD Method. Kit provided with glucose enzyme reagent and standard Glucose (2g/ml). semi automated and Automated GU01 500 ml 5x100 ml GU02 1000 ml 2x500 ml GU03 2000 ml 4x500 ml HDL CHOLESTEROL (LS) Reagent for determining HDL Cholesterol in Methodology: Phosphotungstate / Mg 2+ Method. Product Profile Page 5

Kit provided with HDL Cholesterol precipitating reagent and standard HDL cholesterol (50mg/dl). semi automated and automated PH01 10 ml 1x10 ml PH02 25 ml 1x25 ml PH03 50 ml 1x50 ml PH04 100 ml 2x50 ml HEMOGLOBIN (LS) Reagent for determining hemoglobin in whole human blood. Methodology: Cyanmethemoglobin Kit provided with Hemoglobin reagent and standard Hemoglobin (60mg/dl). Sample Volume : 0.2ml Instrument: Colorimeter, Spectrophotometer, Discrete semi automated and automated Stability of working Solution: Till expiry at room temperature Storage: Hemoglobin Reagents (25-30) Hemoglobin Standard (2 8) HB01 500 ml 1x500 ml HB02 1000 ml 2x500 ml HB03 1000 ml 1x1000 ml HB04 2000 ml 1x2000 ml HB05 5000 ml 1x5000 ml LDH (Lactate Dehydrogenase) (LS) Determination of LDH activity in serum and plasma. Methodology: UV Kinetic Method (Pyruvate to Lactate). Kit provided with Reagent R 1 and R 2 Sample volume : 0.02ml semi automated and automated Stability of working Solution: 60 days at 2 8 LD01 10 ml R 1 1x8 ml R 2 1x2 ml LD02 50 ml R 1 1x40 ml LD03 100 ml R 1 2x40 ml LD04 200 ml R 1 2x80 ml R 2 2x20 ml PHOSPHORUS (LS) Reagent for determining phosphorus activity in Methodology: UV end point method using ammonium molybdate. Kit provided with single reagent R 1. semi automated and automated Product Profile Page 6

PP01 50 ml 1x50 ml PP02 50 ml 2x50 ml GOT/AST (LS) Reagent for determining GOT (AST) activity in Methodology: UV Kinetic Method. Kit provided with reagent R 1 and R 2. semi automated and Automated Stability of working Solution: 60 days at 2 8 PT01 25 ml R 1 1x20 ml R 2 1x5 ml PT02 50 ml R 1 1x40 ml PT03 100 ml R 1 2x40 ml PT04 200 ml R 1 2x80 ml R 2 2x20 ml PT05 250 ml R 1 4x50 ml R 2 2x25 ml PT06 500 ml R 1 4x100 ml R 2 2x50 ml TOTAL PROTEIN (LS) OT01 25 ml R 1 1x20 ml R 2 1x5 ml OT02 50 ml R 1 1x40 ml OT03 100 ml R 1 2x40 ml OT04 200 ml R 1 2x80 ml R 2 2x20 ml OT05 250 ml R 1 4x50 ml R 2 2x25 ml OT06 500 ml R 1 4x100 ml R 2 2x50 ml GPT/ALT (LS) Reagent for determining GPT (ALT) activity in Methodology: UV Kinetic Method. Kit provided with reagent R 1 and R 2. semi automated and Automated Stability of working Solution: 60 days at 2 8 Reagent for determining Total protein in Methodology: Biuret Method. Kit provided with Biuret reagent and standard Total protein (6mg/dl). TP01 50 ml 1x50 ml TP02 100 ml 2x50 ml TP03 200 ml 2x100 ml TP04 250 ml 5x50 ml TP05 1000 ml 2x500 ml Product Profile Page 7

TRIGLYCERIDE (LS) Reagent for determining Triglycerides in Methodology: GOD POD Method. Kit provided with Triglyceride enzyme reagent and standard Triglycerides (200mg/dl). TG01 50 ml 1x50 ml TG02 125 ml 5x25 ml TG03 200 ml 2x100 ml TG04 250 ml 5x50 ml TG05 500 ml 5x100 ml TG06 1000 ml 2x500 ml UREA Reagent for determining urea/blood urea nitrogen. Methodology: Modified Berthelot Method. Kit provided with Enzyme powder R 1, diluents solution R 2, chromogen solution R 3, Standard urea (40mg/dl). Stability of working Solution: 6 months at 2 8 UB01 100 ml R 1 Enz. Vial R 2 1x50 ml R 3 1x50 ml UB02 200 ml R 1 Enz. Vial R 2 1x100 ml R 3 1x100 ml UB03 400 ml R 1 Enz. Vial R 2 2x100 ml R 3 2x100 ml UB04 600 ml R 1 Enz. Vial R 2 3x100 ml R 3 3x100 ml UB05 1000 ml R 1 Enz. Vial R 2 1x500 ml R 3 1x500 ml BUN UREA/GLDH (LS) Reagent for quantitative determination of Blood Urea Nitrogen (BUN)/Urea. Methodology: Enzymatic method using Urease enzyme and Glutamate dehydrogenase (GLDH) enzymes. Kit provided with Reagent R 1, Reagent R 2 and standard BUN (18.69 mg/dl), Urea (40 mg/dl). semi automated and Automated analyzer Stability of working Solution: 45 days at 2 8 UG01 50 ml R 1 1x40 ml UG02 100 ml R 1 2x40 ml UG03 250 ml R 1 4x50 ml R 2 1x50 ml UG04 500 ml R 1 4x100 ml R 2 1x100 ml Product Profile Page 8

URIC ACID (LS) Reagent for determining uric acid in plasma or serum. Methodology: Uricase POD Method Kit provided with Uric acid reagent and standard Uric acid (6mg/dl). Sample volume: 0.025ml Instrument: Spectrophotometer, Discrete semi automated and Automated analyzer Stability of working Solution: Till expiry at 2 Shelf life : 18 months Storage: 2 8 C UA01 50 ml 1x50 ml UA02 125 ml 5x25 ml UA03 200 ml 2x100 ml UA04 250 ml 5x50 ml UA05 500 ml 5x100 ml UA06 1000 ml 2x500 ml Product Pro ile Page 9