Analysis of Chloride, Phosphate, Malate, Sulfite, Tartrate, Sulfate, and Oxalate in Red and White Wine

Similar documents
Sugar analysis according to the EU Regulation using amperometric detection and Metrosep Carb 2-150/4.0

Rapid determination of phosphate and citrate in carbonated soft drinks using ion chromatography

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

Determination of Inorganic Ions and Organic Acids in Non-Alcoholic Carbonated Beverages

Determination of Organic Acids in Kombucha Using a High-Pressure Ion Chromatography System

Mercury Speciation Determinations in Asian Dietary Supplements

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Determination of Ethyl Sulfate Impurity in Indinavir Sulfate Drug Using Ion Chromatography

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

Fig.1. Denatonium benzoate (DB) chemical structure

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Validation of Isovaleraldehyde Using SKC UMEx 100 Diffusive Samplers (Cat. No )

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

retardation in infants. A wide variety of analytical methods for the analysis of

Application Note 178 INTRODUCTION

IC-MS Environmental Applications - Water Testing. Application Notebook

using the Agilent 7696A Sample Prep

Rapid Determination of Phosphate and Citrate in Carbonated Soft Drinks Using a Reagent-Free Ion Chromatography System

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Application Note 178. Brian DeBorba and Jeff Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA. 10 Typically, this requires the use of sample

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Pesticide Residue Analysis in Whole Milk by QuEChERS and LC-MS/MS

Application Note. Author. Abstract. Introduction. Food Safety

Determination of Copper in Green Olives using ICP-OES

Determination of Methacholine Chloride and Potential Impurities Using a Reagent-Free Ion Chromatography System

Simultaneous Analysis of Norepinephrine, Dopamine and Serotonin in 15 Minutes

EASIMIP TM PATULIN Product Code: P250 / P250B

Standard Operating Procedure for Chloride and Silica in Lake Water (Lachat Method)

CORESTA Recommended Method No. 85

Bisphenol A in Drinking Water

B. 1% (w/v) Salicin Substrate Solution (Salicin) (Prepare 50 ml in Reagent A using Salicin, Sigma Prod. No. S-0625.)

Ion Chromatography: A Versatile Technique for the Analysis of Beer

1 out of 8. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 86th Meeting 2018 ERYTHROSINE

Determination of Sucralose Using HPAE-PAD

Analysis of Phenolic Antioxidants in Edible Oil/Shortening Using the PerkinElmer Altus UPLC System with PDA Detection

Data sheet. TBARS Assay kit. (Colorimetric/Fluorometric) Kit Contents. MDA-TBA Adduct. 2-Thiobarbituric Acid. Cat. No: CA995.

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column

2D-LC as an Automated Desalting Tool for MSD Analysis

Standard Operating Procedure for Total and Dissolved Phosphorous (Lachat Method)

Enzymatic Assay of ß-GLUCOSIDASE (EC )

Ergovaline. [Methods listed in the Feed Analysis Standards] 1 Liquid chromatography Note 1, 2 [Feed Analysis Standards, Chapter 5, Section 2

HYDROXYPROPYLCELLULOSE, LOW SUBSTITUTED Stage 4, Revision 1 CP: USP BRIEFING NOTE

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Determination of taurine in energy drinks by high-performance liquid chromatography

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610

Rapid Quantitative Analysis of Cannabidiol from Consumer Products Using UltraPerformance Convergence Chromatography

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Forensic Analysis of Blood Alcohol Concentration

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA200

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Pelagia Research Library

HEPARIN SODIUM. Heparinum natricum

Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

CORESTA RECOMMENDED METHOD NÄ 9

Determination of Tigecycline in a Cell Lysate

Preparation of Penicillins by Acylation of 6-Aminopenicillanic acid with Acyl Chlorides Week One: Synthesis

This revision also necessitates a change in the table numbering in the test for Organic Impurities.

Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and Its Metabolites in Fish

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Lipidomic Analysis by UPLC-QTOF MS

Relative Measurement of Zeaxanthin Stereoisomers by Chiral HPLC

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Cholesterol determination using protein-templated fluorescent gold nanocluster probes

Determination of Amantadine Residues in Chicken by LCMS-8040

SACCHARIDES (Liquid Chromatography)

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

HPAE-PAD Determination of Infant Formula Sialic Acid

Pelagia Research Library

2.1 Determination of Ethanol (Ethyl Alcohol)

Analysis of mycotoxins in food matrices using the Agilent Ultivo Triple Quadrupole LC/MS

Determination of Iodide and Iodate in Seawater and Iodized Table Salt by HPLC with UV Detection

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

ISSN : Identification and relative ratios of cations and anions in orange juice, banana, soft drink, and various mineral tablets

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

Photosensitivity of Internal Standard Valerophenone

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Determination of Lactose in Lactose-Free Milk Products by High-Performance. anion-exchange chromatography with. Pulsed Amperometric Detection

E17 ETHYLCELLULOSE. Revision 3 Stage 4

Transcription:

Application Work AW US6-0249-062017 Analysis of Chloride, Phosphate, Malate, Sulfite, Tartrate, Sulfate, Branch Food, stimulants, beverages, flavors Keywords IC; 940; Conductivity; Chloride; Phosphate; Sulfate; Sulfite; Malate; Tartrate; Oxalate; Anions; 858; MagIC Net 3.2; Metrosep A Supp 10-100/4.0; Ultrafiltration; Wine Summary Product consistency and quality is of utmost importance to winemakers. It is also critical to monitor and evaluate yeast performance and efficiency throughout the fermentation process. This wine analysis can aid vintners with ensuring predictable flavor and aroma characteristics in finished wine by monitoring common indicators of acidity, mouthfeel, and balance. It also evaluates nutrients and other additives which could potentially have deleterious effects on efficiency and production during the fermentation process. This application work shows the use of Metrohm IC to analyze red and white wine for chloride, phosphate, sulfite, sulfate, malate, tartrate, and oxalate. For this work, a Metrohm Professional IC with sequential suppression and conductivity detection was used in combination with the 858 Sample Processor with Ultrafiltration. The in-line Ultrafiltration protects the column and system components from particulates and ensures trouble-free operation. The rapid analysis enables high throughput laboratories to maximize production. Dosino regeneration and STREAM rinsing are used for the MSM. Reagents Sodium Carbonate, CAS 497-19-8: Sigma Aldrich 223484-500G, 99.95 100.05% Sodium Bicarbonate, CAS 144-55-8: Sigma Aldrich S6014-500G, 99.7 100.3% Sodium Sulfite, CAS 7757-83-7: Sigma Aldrich 71989-250G, 98% Tartaric Acid, CAS 87-69-4: J.T. Baker 4104-01 Malic Acid, CAS 617-48-1: J.T. Baker P494-07 Oxalic Acid, CAS 144-62-7: Sigma Aldrich 658537-100G, 99.999% trace metals basis Perchloric Acid, CAS 7801-90-3: Sigma Aldrich 311421-50mL, 99.999% trace metals basis Sulfuric acid, CAS 7664-93-9 Ultrapure water, resistivity >18 MΩ cm (25 C) Metrohm Individual Anion Standards, 1000 ppm Instruments o o o Chloride, Metrohm USA ERA-IC1002 Phosphate, Metrohm USA ERA-IC Sulfate, Metrohm USA ERA-IC1007 940 Professional IC Vario ONE/SeS 2.940.1400 IC conductivity detector 2.850.9010 858 Professional Sample Processor 2.858.0020 Sample Rack 148 place + 3 Special Beakers 6.2041.440 MagIC Net 3.2 6.6059.322 Metrosep A Supp 10-100/4.0 6.1020.410 800 Dosino 2.800.0010 Dosing Unit 2 ml 6.3032.120 Ultrafiltration Equipment 6.5330.110 20 µl sample loop 6.1825.210 MSM Rotor A 6.2832.000 Filtration Membrane, 0.2 µm 6.2714.020 Pump tubing LFL (yellow/yellow) 6.1826.390 Pump tubing LFL (black/black) 6.1826.340 Solutions Eluent: 5.0 mmol/l sodium carbonate + 5.0 mmol/l sodium bicarbonate + 5 µmol/l perchloric acid Regenerant for Suppressor: 500 mmol/l sulfuric acid Samples Red wine White wine Standards 1000 ppm stock standards were used for all analytes. Sulfite, tartrate, malate, and oxalate stocks were prepared Page 1 of 9

from salts. Chloride, phosphate, and sulfate were prepared using commercially purchased standards. Sulfite was calibrated separately due to sulfate contamination in the sodium sulfite salt. Sulfite stock standard was fixed with 10% isopropanol and working standards were fixed with 2% isopropanol in order to prevent oxidation of sulfite to sulfate. In ultrapure water (ppm) S1 S2 S3 S4 S5 S6 Chloride 1 5 10 25 50 100 Phosphate 1 5 10 25 50 100 Malate 1 5 10 25 50 100 Sulfite 1 5 10 25 50 100 Tartrate 1 5 10 25 50 100 Sulfate 1 5 10 25 50 100 Oxalate 1 5 10 25 50 100 Sample Preparation Wine samples were gravimetrically diluted 1:10 and 1:50 in ultrapure water. Vial caps were used to minimize oxidation. Samples were then directly injected by the 858 with ultrafiltration. Comments This application may be deployed utilizing a 930 Compact IC Flex, and is also suitable for use with Metrohm s In-Vial Dilution Technique (MiVDT). Acetate was not quantified and is shown in the sample chromatograms for identification purposes. If oxalate is not present, the run time may be slightly reduced. References AW US6-210-122014: Metrohm In-Vial Dilution Technique (MiVDT) for Anions with Intelligent Dilution, Ultrafiltration, Analyte Delimiter Logic, and Eluent Production Module Date June 14, 2017 Author Ashley R. Wittig Metrohm USA Inc. IC Parameters Anion eluent flow 1.0 ml/min Column temperature 35 C Injection volume 20 μl Anion Pmax 20 MPa MSM Rinsing STREAM MCS On Degasser On Recording Time 20 minutes Calculation Automatic integration with MagIC Net 3.2 software using peak area for all analytes. Results All results summarized in the appendix. Page 2 of 9

Instrumentation Set-Up Page 3 of 9

Calibration Curves Page 4 of 9

Page 5 of 9

Results Red Table Wine (ppm) Chloride Phosphate Malate Sulfite Tartrate Sulfate Oxalate Dilution Replicate 1 60.0 771.9 92.2 26.1 1754.5 553.0 <10 10 (50 for tartrate) Replicate 2 60.0 769.7 92.1 26.9 1754.9 553.0 <10 10 (50 for tartrate) Replicate 3 60.0 773.3 92.1 27.0 1757.5 553.0 <10 10 (50 for tartrate) Average 60.0 771.6 92.1 26.7 1755.6 553.0 <10 RSD (%) 0.027 0.23 0.064 1.9 0.092 0.007 White Table Wine (ppm) Chloride Phosphate Malate Sulfite Tartrate Sulfate Oxalate Dilution Replicate 1 21.6 817.8 105.2 28.9 1529.8 366.7 <10 10 (50 for tartrate) Replicate 2 21.5 817.3 105.6 28.7 1544.0 366.7 <10 10 (50 for tartrate) Replicate 3 21.5 818.9 105.3 28.7 1528.8 366.7 <10 10 (50 for tartrate) Average 21.5 818.0 105.3 28.8 1534.2 366.7 <10 RSD (%) 0.040 0.098 0.19 0.44 0.56 0.009 Page 6 of 9

Chromatography Calibration Standards, all analytes calibrated 1 100 ppm Chloride Sulfite working standards prepared in 2% isopropanol Sulfite Sulfate contamination Page 7 of 9

Red wine, 1:10 dilution, overlay of three injections Acetate Phosphate Tartrate Sulfate Chloride Red Wine Chloride Phosphate Malate Sulfite Tartrate Sulfate Oxalate (ppm) Average 60.0 771.6 92.1 26.7 1755.6 553.0 <10 RSD (%) 0.027 0.23 0.064 1.9 0.092 0.007 Acetate not quantified. Page 8 of 9

White wine, 1:10 dilution, overlay of three injections Acetate Phosphate Tartrate Sulfate Chloride White Wine Chloride Phosphate Malate Sulfite Tartrate Sulfate Oxalate (ppm) Average 21.5 818.0 105.3 28.8 1534.2 366.7 <10 RSD (%) 0.040 0.098 0.19 0.44 0.56 0.009 Acetate not quantified. Page 9 of 9