Vibration Analysis of Finger Using Non linear FEM to Understand HAV Syndrome

Similar documents
Estimation of the Upper Limb Lifting Movement Under Varying Weight and Movement Speed

Soft tissue biomechanics

Muscular Skeletal Disorders

Hand Anatomy A Patient's Guide to Hand Anatomy

Work Related Musculoskeletal Disorders

Ergonomics Glossary. Force The amount of physical effort a person uses to do a task.

Evaluation of Handle Diameter in Maximum Horizontal and Vertical Torque Tasks. Yong-Ku Kong and Brian D. Lowe

Clinical examination of the wrist, thumb and hand

Multi-joint Mechanics Dr. Ted Milner (KIN 416)

D. G. Kamper 1,2, W. Z. Rymer 1,2

Anatomy, Biomechanics, Work Physiology, and Anthropometry. After completing and understanding of the current chapter students should be able to:

Simulating the Dynamic Muscle Force in an Index Finger During Tapping

Modal Analysis of Hip Joint Implant Used In the Human Body

THORAX FP7 Workshop Task 2.4 Dummy Concepts

Q: What is the relationship between muscle forces and EMG data that we have collected?

Update on Seismic Behavior and Design of

This presentation is the intellectual property of the author. Contact them for permission to reprint and/or distribute.

THE WRIST. At a glance. 1. Introduction

Structural Analysis of Human Body Impact

The Physiology of the Senses Chapter 8 - Muscle Sense

Skeletal Muscles and Functions

Musculoskeletal Simulation in an Automotive Environment The web cast will start in a few minutes. Amir Al-Munajjed AnyBody Technology

ERI Safety Videos Videos for Safety Meetings. ERGONOMICS EMPLOYEE TRAINING: Preventing Musculoskeletal Disorders. Leader s Guide 2001, ERI PRODUCTIONS

Five-Fingered Assistive Hand with Mechanical Compliance of Human Finger

Goals. Vibration I njury in the Workplace. Definitions HAVS. HAVS (cont.) HAVS (Cont.)

13/02/2011. Ergonomics

Biodynamic Response To Random Whole Body Vibration In Standing Posture

Risk Factors and Control Measures for Musculoskeletal Injuries. Presented by: Gina Vahlas, Ergonomist Chloe Eaton, Ergonomist

The Development and Analysis of an FEA Simulation on an Artificial Knee

Therapy Management PIPJ stiffness. Gemma Willis SUHT

Duputytren's Contracture

According to the Occupational Safety and Health Administration OSHA many office workers report work-related musculoskeletal disorders or MSDs every


An Investigation of Hand Force Distribution, Hand Posture and Surface Orientation

VARYING SPRING PRELOADS TO SELECT GRASP STRATEGIES IN AN ADAPTIVE HAND

Finite Element Analysis of Radius and Ulna. Eli Pavlatos April 24, 2013

Department of Defense Ergonomics Working Group

BUNNELL. Expanded product line Customer service Please visit BunnellSplints.com Sizing information on back page WRIST HAND FINGER ORTHOSIS

Ergonomics in Sonography

Modelling of temporomandibular joint and FEM analysis

Mechanical Properties of the Cochlea. Reading: Yost Ch. 7

Introduction to Ergonomics Ergonomics (er'gõ nom'iks):

The Ergonomic Alternative

Introduction to Biomedical Engineering

Chapter 5. Joint Classifications. Synarthroses. Amphiarthroses Slightly movable joints such as: Synchondroses 1 st sternocostal

Resources: Ergonomic/Musculoskeletal Hazards in Patient Handling. Sustained and/or Awkward Postures. Contact Stresses or Pressures

Modeling of human knee joint and finite element analysis of landing impact motion

Swan-Neck Deformity. Introduction. Anatomy

Repetitive Upper Limb Tasks. Introductions. ' Crown Copyright Health & Safety Laboratory. 1. Dr Lanre Okunribido: HSL Ergonomist.

A Patient s Guide to Elbow Anatomy

3M Center for Hearing Conservation

Utility of Instrumented Knee Laxity Testing in Diagnosis of Partial Anterior Cruciate Ligament Tears

Ergonomic Design of Trowel Handle

Key Points for Success:

Fatigue life prediction methodology of automotive rubber component. *Chang-Su Woo 1)

NON DESTRUCTIVE STRUCTURAL ASSESSMENT OF BRIDGES USING IN-SERVICE DYNAMIC RESPONSE

VALIDATION OF RADIOCARPAL JOINT CONTACT MODELS BASED ON IMAGES FROM A CLINICAL MRI SCANNER. Joshua Eddie Johnson

2/28/2017. EMC Insurance Companies Risk Improvement Department. Ergonomics for School Districts. Objectives. What is Ergonomics?

Session Objectives. Business & Legal Reports, Inc. 0903

BSL PRO Lesson H03: Nerve Conduction Velocity: Along the Ulnar Nerve of a Human Subject

Biomechanical Modelling and Animating Human Hand Movements

Posture. Posture Evaluation. Good Posture. Correct Posture. Postural Analysis. Endomorphs

Electrical stimulation of the upper limb. Paul Taylor

A new computer mouse called Horse

A Patient s Guide to Adult Finger Fractures

Finite Element Analysis (FEA) of Swanson Flexible Hinge Toe Implant

Clinical Policy: Mechanical Stretching Devices for Joint Stiffness and Contracture

Occupational Vibration Exposure

Finger Mobility Deficits Fracture of metacarpal Fracture of phalanx of phalanges

The Upper Limb. Elbow Rotation 4/25/18. Dr Peter Friis

Introduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand.

Mechanical Aspects of an Interference Screw Placement in ACL Reconstruction

Chapter 5. Finger Model: Extensor and Flexor mechanisms 5.1 INTRODUCTION

Interesting Case Series. Swan-Neck Deformity in Cerebral Palsy

Physical therapy of the wrist and hand

Reversing PIP Joint Contractures:

Muscle-Tendon Mechanics Dr. Ted Milner (KIN 416)

The University of Sydney Slide 1

Main Menu. Wrist and Hand Joints click here. The Power is in Your Hands

Copyright Warning & Restrictions

ACCURATE NUMERICAL ANALYSIS OF GEAR STRENGTH BASED ON FINITE ELEMENT METHOD

WEARABLE TREMOR REDUCTION DEVICE (TRD) FOR HUMAN HANDS AND ARMS

Dr. Klika Metacarpal Fracture with CRPP

Lever system. Rigid bar. Fulcrum. Force (effort) Resistance (load)

Unit 7: Skeletal and muscular systems

Musculoskeletal Assessment ANATOMY AND PHYSIOLOGY

Wrist & Hand Assessment and General View

Fly-Fishing Preseason Prep

Reassessing Flexor Tendon Excursion Models with Colour Doppler Ultrasonography

First Technology Safety Systems. Design Freeze Status. Flex-PLI-GTR Development

Structure and Function of the Hand

Neuromuscular Mechanics

The Effect of Sitting Posture on Human Movement in Whole-Body Vibration

Sport-Thieme therapy dough

Muscle Tissue. Isometric Contraction. Isotonic Contractions 11/22/2016. Muscles. Anatomy Two Joints And Movements

PHYS 1240 Sound and Music Professor John Price. Cell Phones off Laptops closed Clickers on Transporter energized

SaeboGlove. Saebo INSTRUCTION MANUAL. New Era in Hand Rehabilitation

Flexibility - an important feature of the human middle ear's ossicular chain

Transcription:

Vibration Analysis of Finger Using Non linear FEM to Understand HAV Syndrome Shrikant Pattnaik, Jay Kim Dept. of Mechanical Engineering University of Cincinnati

What is HAVS Hand Arm Vibration Syndrome Excessive vibration from Hand Tool causes MSD Muscoskeletal Sensorineural Vasospastic Raynaud s disease (blanching, numbness, pain) affects motor function

Modeling Techniques Frequency Low (0 50Hz) Lumped parameter model Mid (50 250Hz) Flexible Body Model, FEA High (250 ) Wave Propagation Vibration Transmission Strain Energy Absorption Interference Joint & Muscle Pain Tissue Damage Blood flow disruption [Wells 1985]

Modeling Lumped Parameter Kinematic Model

LifeMOD A plug in of ADAMS plug in module to the ADAMS physics engine. Human models can be combined with any ADAMS model for full dynamic interaction. Additional plug ins e.g. KneeSIM, NeckSIM are available through LifeMOD. * http://www.lifemodeler.com/ LM_Manual

HandSIM A plug in of LifeMOD

Building Model Building a Model Segments Joints Soft Tissues Muscle Model Passive Modeling Active Modeling

Kinematic Modeling Accurate geometry/mass properties 50 th percentile human male attributes Tri axial stiff joints, muscle with tissue wrapping Tension only muscle and tone defined Posture prediction Pre load estimation

Results: Frequency Response Joint 12 (red) vs. elbow joint (magenta) vs. wrist (blue) z accelerations upon input acceleration of 1 / at tip of cm of index finger.

Assumptions/Issues of Lumped Model Assumptions Lumped Parameter based Model: Predefined degrees of freedom Linearity, non viscous parameters Hand tool rigid body based (only force and displacement) Assuming small displacements at the handle location, the dynamic response of the hand arm system is considered to be uncoupled along its three orthogonal directions. ISO 8727 Issues: High static deflections Lower natural frequencies with less mass and stiffness values in the parameters Dissipative property and other nonlinear behavior cannot be seen.

Modeling Flexible Body (Finite Element)

Finite Element Model Bone Soft Tissue Skin Nail Tendon Synovial Fluid Cartilage Ligament Sheath

Finite Element Model Pre loaded tendon Static deflection Dynamic simulation Modal Extraction High frequency response

Results: Dynamic response Frequency response Stress/Strain evaluation Localized behavior with higher frequency 1Hz 126Hz 500Hz

Results: Frequency Response Mode Freq(Hz) Mode Freq(Hz) 1 62.86 11 192.26 2 73.69 12 196.72 3 92.04 13 206.72 4 107.43 14 214.26 5 128.86 15 220.78 6 134.83 16 226.78 7 142.45 17 230.38 8 159.85 18 235.70 9 168.29 19 241.83 10 179.34 20 243.39

Observation 1/2: Relative Muscle Contribution Nonlinear response Flexor four times size of Extensor Short and long range force output Static vs. Dynamic counterbalance

Observation 2/2: Activated Response Distal Interphalangeal (DIP) Joint

Coupled Modeling Rigid + Flexible Kinematic + Finite Element

Rigid Flexible Coupled Approach Steps LifeMOD export IGES ABAQUS substructure extract modes Run Macro Mode Neutral File Import LifeMOD replace rigid with Flex Stress/Strain Contour on a Flexible part

Discussion 1/3 Damping can occur by three mechanisms: passive damping properties of elastic tissue and tool surface force velocity properties of active muscle well timed activation pulses that occur when a muscle is in the lengthening phase of the vibration. ( Low freq ) High freq passive spring series element (Hill s model)

Discussion 2/3 Extrinsic (Flexor) creates static grip force. dynamic load Extensor & Intrinsic Interphalangeal joint stabilized with co activation Transmission of vibration increases with cocontraction. Higher grip force > higher impedance and higher resonance (muscles stiffened) Higher muscle force higher stiffness lesser is the deformation needed to absorb same energy

Discussion 3/3 Under dynamic loading friction coefficient of articular cartilage reduces Fast Dynamic load elastic behavior (approx.) Tougher the component and the greater the volume more strain energy it is likely to absorb. Capacity of absorbing strain energy Highest Tendon 65 times of muscle Bone 55 times of muscle Lowest Muscle

Conclusion/Future Work Improve Combined approach (Kinematic and FE) High frequency > faster Type II (vs. Slower Type I) Rest of the segments of hand Contact stress evaluation Fatigue model

Thank You Acknowledgements Advisor Dr. Jay Kim Dr. Rupak Banerjee Dr. Ren Dong & NIOSH Morgantown Team P&G/UC Simulation Center This research study was (partially) supported by the National Institute for Occupational Safety and Health Pilot Research Project Training Program of the University of Cincinnati Education and Research Center Grant #T42/OH008432 05.