Three-dimensional finite element analysis of the application of attachment for obturator framework in unilateral maxillary defect

Similar documents
Frame designed partial prosthesis for the rehabilitation of a maxillectomy patient

It has been proposed that partially edentulous maxillectomy

Frequency of the Various Classes of Removable Partial Dentures and Selection of Major Connectors and Direct/Indirect Retainers

DENT Advanced Topics in Removable Prosthodontics, Winter 2008

Lect. 14 Prosthodontics Dr. Osama

PROSTHETIC REHABILITATION OF MAXILLARY DEFECTS: A REVIEW

1- Implant-supported vs. implant retained distal extension mandibular partial overdentures and residual ridge resorption. Abstract Purpose: This

DENT Advanced Topics in Removable Prosthodontics, Winter 2008

Indirect retainers. 1 i

Influence of Implant Position on Stress Distribution in Implant-Assisted Distal Extension Removable Partial Dentures: A 3D Finite Element Analysis

PROSTHETIC REHABILITATION OF MAXILLECTOMY PATIENT WITH TELESCOPIC DENTURES

The aim of this study was to evaluate the use of esthetic twin-flex clasp on remaining

BIOMECHANICAL ANALYSIS OF THE APPLICATION OF ZYGOMA IMPLANTS FOR PROSTHESIS IN UNILATERAL MAXILLARY DEFECT

SCD Case Study. Attachments in Prosthodontics

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

Prosthodontic Rehabilitation of a Partially Edentulous Hemiglossectomy Patient: A Clinical Report

INCREASED RETENTION OF A PARTIAL DENTURE MAXILLARY OBTURATOR USING DENTAL IMPLANT

Journal of American Science 2010;6(9) Emiel A. M. Hanna *1 and Salah A. F. Hegazy 2

م.م. طارق جاسم حممد REMOVABLE PARTIAL DENTURE INTRODUCTION

CAUSE OF TECHNICAL FAILURES OF CONICAL CROWN-RETAINED DENTURE (CCRD): A CLINICAL REPORT

A retrospective study on separate single-tooth implant restorations to replace two or more consecutive. maxillary posterior teeth up to 6 years.

Prosthetic V. Removable dentures I.

Principles of. By: Dr. Ahmad Rabah

INDIAN DENTAL JOURNAL

Removable partial dentures

Australian Dental Journal

Fixed Partial Dentures /FPDs/, Implant Supported. in implant prosthodontics

Osseointegrated implant-supported

Available online at ScienceDirect

AESTHETIC DESIGNS IN REMOVABLE PARTIAL DENTURES

Paper submission. Denture repair with the application of a magnetic attachment to the inner crown of a telescopic crown: A 3-year follow-up case

Rehabilitation of Acquired Maxillary Defect with Precision Attachment Retained Hollow Bulb Obturator prosthesis: A Case Report

Component parts of Chrome Cobalt Removable Partial Denture

ACRYLIC REMOVABLE PARTIAL DENTURE(RPD)

In-Silico approach on Offset placement of implant-supported bridges placed in bone of different density in Orthodontics.

Clasp design. Many RPD design principles are based. prosthetics PRACTICE

DIAGNOSTIC/PREVENTIVE SERVICES

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

Objectives: In some clinical situations, dentists come across partially edentulous patients,

DL 313 Removable Partial Dentures II

Bone Reduction Surgical Guide for the Novum Implant Procedure: Technical Note

Dual Path: A Concept to Improve the Esthetic Replacement of Missing Anterior Teeth with a Removable Partial Denture

FEM analysis of the mandibular first premolar with different post diameters

Comparative study of single-thread, double-thread, and triple-thread dental implant: a three-dimensional finite element analysis

M.D.S. DEGREE EXAMINATION. (Revised Regulations) Branch VI PROSTHODONTICS. (For Candidates admitted from onwards)

Telescopic Retainers: An Old or New Solution? A Second Chance to Have Normal Dental Function

Evaluation of fixed partial denture in relation to gingival recession and other factors

Selection and arrangement of teeth in rpd

Attachment Retained Cast Partial Denture: Conventional and Contemporary Treatment Perspectives

ABSTRACT INTRODUCTION

FINITE ELEMENT ANALYSIS OF PERIODONTAL STRESSES IN FIXED PROSTHODONTICS

Stress and Displacement Analysis of Dental Implant Threads Using Three-Dimensional Finite Element Analysis

Dynamic retentive force of a mandibular unilateral removable partial denture framework with a back-action clasp

Restoration of the worn dentition

The CMC approved a motion to accept all editorial action requests that remain on the consent calendar 21 Yea / 0 Nay / 0 Abstain

ATTACHMENT AA DentaQuest of Illinois, LLC

MEDICAL UNIVERSITY OF VARNA FACULTY OF DENTAL MEDICINE DEPARTMENT OF PROSTHETIC DENTAL MEDICINE GOVERNMENT EXAMINATION SYLLABUS

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

SURVEYING OF REMOVABLE PARITAL DENTURES FEB, 11, 2015

Comparative analysis of the stress distribution in five anatomical types of maxillary central incisor

Experimental and Numerical Comparison of Stresses Level between Titanium and Novel Composite Single Tooth Implant

Case Report Prosthodontic Rehabilitation Alternative of Patients with Cleft Lip and Palate (CLP): Two Cases Report

Requests for a fixed restoration of lost mandibular

Prosthodontic Rehabilitation with Overdenture Using Modified Impression Technique: A Case Report

Removable Partial Dentures

Cleft lip and palate; oronasal istula; prosthetic treatment; O ring attachment

Removable Partial Denture Design: A Study of a Selected Population in Saudi Arabia

International Journal of Dentistry and Oral Science (IJDOS) ISSN:

Dental Implant Treatment Planning and Restorative Considerations

The removable implant supported prosthesis for the upper jaw

Case Report Prosthodontic Rehabilitation of the Patient with Severely Worn Dentition: A Case Report

Construction of Removable Partial Denture

Types of prostetic appliances Dr. Barbara Kispélyi

Evaluation of Stress Distribution in Bone of Different Densities Using Different Implant Designs: A Three-Dimensional Finite Element Analysis

Finite Element Analysis of Dental Implant as Orthodontic Anchorage

Shaama et al: Tooth loss and denture designs

Oral Rehabilitation with CAMLOG implants after loss of dentition due to an accident

Use of Wave-MV to bond an artificial tooth with a fixed partial denture

DENTAL RATE FEE SCHEDULE rates effective 5/1/15 through 6/30/15

Comparison between Acetal Resin and Cobalt-Chromium. Removable Partial Denture Clasp Retention: An in vitro Study.

"Designing a fixed partial denture without a pontic"- Case report

Indications The selection of amalgam as a restorative material for class V cavity should involve the following considerations:

Distal extension base removable partial dentures exhibit composite type of support

Mechanical and technical risks in implant therapy.

Stress in the Mandible with Splinted Dental Implants caused by Limited Flexure on Mouth Opening: An in vitro Study

Infraocclusion Treated with Removable Prosthesis on Occlusal Surface of Severely Attritioned Teeth

Maxillofacial prosthetics is a subspecialty of

CLASSIFICATION OF RPDs AND PARTIALLY EDENTULOUS ARCHES

Employee Benefit Fund July 2018 ADA Codes and Plan Fees

AO Certificate in Implant Dentistry Certificate

Class II correction with Invisalign - Combo treatments. Carriere Distalizer.

Young-Jin Park, DDS,* and Sung-Am Cho, DDS, MS, PhD

The evolution of implant restorative options has rapidly arrived at the point of

Root fracture is a common and serious cause of

Scheduled Dental Benefit Plan Schedule of Dental Allowances

6. Timing for orthodontic force

Resin-bonded casting used as an anterior fixed partial denture retainer: A clinical report

Samantha W. Chou, D.M.D N. Southport Ave. Chicago, Illinois Phone: Fax:

Transcription:

Journal of Oral Rehabilitation 2007 Three-dimensional finite element analysis of the application of attachment for obturator framework in unilateral maxillary defect S. JIAN*, J. TING*, T. YING &W.DONG-MEI *Department of Prosthodontics, School of Stomatology, Ninth People s Hospital, Shanghai Jiaotong University and Department of Mechanics, Shanghai Jiaotong University, Shanghai, China SUMMARY AIMS: The aim of this study was to evaluate the stress on the abutment teeth and framework in a unilateral maxillary defect which was restored by an obturator retained by resin-bonded extracoronal attachment. METHODS: A three-dimensional finite element model of the human unilateral maxillary defect was constructed. Traditional obturator framework with four casting circumferential clasp was established (model 1). A continuous lingual guide plane of 0Æ5 mm thickness on all of the remaining teeth, with Mini-SG F attachment on the mesial surface of the central incisor was also established (model 2). The modelling and analytical processes were performed using the ANSYS technologies. RESULTS: Stress was transmitted to the anterior part of the palate, with stress values being lower on the anterior teeth compared with the posteriors. The highest stress value of model 1 and model 2 was 13Æ1 Mpa, 19Æ9 Mpa respectively. Stress concentrations were found at the junction of the attachment to the lingual guide plane and the anterior part of the lingual plane. CONCLUSION: The results of this study suggest that the application of a resin-bonded extracoronal attachment for obturator retention is in accordance with the design principles for the restorative treatment of maxillary defects. The design of the attachment framework needs to be further investigated. Benefit can be gained by splinting the abutment teeth. KEYWORDS: 3D FEA, attachment, obturator, unilateral maxillary defect Accepted for publication 15 July 2007 Introduction Obturator prostheses are considered to be the preferred choice for the restoration of acquired maxillary defects. The rehabilitation of a maxillary defect with an obturator retained by a resin-bonded extracoronal attachment, which can improve both retention and aesthetics, is commonly practiced when a central or lateral incisor is the terminal abutment adjacent to a large defect (1 4). Taylor et al. demonstrated the use of resin-bonded metal components in the fabrication of definitive obturators for dentate maxillectomy patients (1). The resin-bonded metal components served as guide plane, cingulum rest seats which have been used for abutment teeth modification, so that the remaining teeth will be in a favourably position to support and retain an obturator prosthesis. And it may also serve as splints to splint the abutment that can reduce functional tooth movement by averaging the movement of individual teeth when either the abutment teeth or obturator are subjected to loading (2, 4 6). Because of a lack of supporting tissues, including teeth and bone, the objective of the framework design of an obturator is to preserve the remaining support structures (7). Research has been conducted to evaluate the stress transmitted to the remaining teeth and other supporting structures by attachments with different framework designs. Although the use of attachments with guide planes for maxillary obturators have been successful in the clinic, their biomechanical analyses had rarely been found in the literature. It has been assumed that the components doi: 10.1111/j.1365-2842.2007.01801.x

2 S. JIAN et al. of the resin-bonded casting guide plane with attachment would be subjected to more severe stress in comparison to the conventional removable partial denture attachment. This study investigated, by threedimensional finite element of analysis, the stress transmitted to the abutment teeth and the casting guide plane with attachment in the unilateral maxillary defect that is commonly seen in the maxillectomy patient. Materials and methods Model 2 (an obturator retained by a resin-bonded extracoronal attachment) The continuous lingual guide plane, with a thickness of 0Æ5 mm thick on all lingual surface of the remaining teeth (from central incisor to second molar) with Mini- SG F* attachment on the mesial surface of the central incisor was constructed (Fig. 2). The obturator prostheses with casting palatal plate were also constructed according to the lingual guide plane and the condition of the maxillary defects (Fig 3). Three-dimensional data of the human maxilla were obtained via helical CT (GE-Lightspeed Qx I, GE, USA), which were transferred into MIMCS software (Materialise, Belgium) generating a 3D model of the maxilla. The model was converted into ANSYS to establish the 3D FEM of the maxilla that simulated the unilateral maxillary defect along with the remaining teeth from the central incisor to the second molar on one side. The area around the teeth root with 0Æ5 mm uniform thickness was treated as periodontal membrane.the 3D FEM of two kind of obturator prostheses were established: Model 1 (traditional treatment) Removable partial denture frameworks with extension bases extending into the defect were constructed. The framework designs included cast palatal base with 0Æ5 mm thickness with four cast circumferential clasp using 0Æ25 mm undercut on the buccal surface (Fig. 1). Fig. 2. 3D FEM of the lingual guide plane on all the remaining teeth (from central incisor to second molar) with attachment on the mesial surface of the central incisor. Fig. 1. 3D FEM of traditional obturator prostheses with four cast circumferential clasp. Fig. 3. 3D FEM of the obturator prostheses with casting palatal plate. *Cendres & Metaux SA, Biel, Switzerland.

FEA OF MAXILLARY OBTURATOR WITH ATTACHMENT 3 The whole vertical load on all of the remaining natural teeth was 300N, out of which the load is distributed as, 20N on every anterior teeth, 40N on every premolar, 80N on every molar. While the whole vertical load on all of the artificial teeth was 150N, the load is distributed as 10N on every anterior teeth, 20N on every premolar, 40N on every molar. And the load on every tooth was evenly distributed. The non-defect sides of the Maxilla were designated as fixed regions with zero displacement. And it was assumed that the prostheses and maxilla would have perfect bonding. With respect to material properties, the elastic modulus of cortical bones, spongy bone, chrome cobalt alloy and artificial teeth was 13 700, 1850, 18 500, 2799 Mpa respectively. The Poisson s ratio was 0Æ35 for artificial teeth and 0Æ30 for the other materials. The area around the teeth roots with 0Æ5 mm uniform thickness was treated as periodontal membrane. And the elastic modulus of periodontal membrane was 6Æ5 Mpa. The Poisson s ratio was 0Æ45. A tetrahedron, iso-parametric element was adopted. All of the materials used in these models were considered to be isotropic, homogenous and linearly elastic. The modelling and solution processes were performed using ANSYS 5Æ6. Fig. 5. Stress on the remaining teeth (model 1). Results Figures 4 6 show a conventional von Mises stress pattern in the traditional obturator prosthesis and the remaining teeth (model 1). Figures 7 10 show a Fig. 6. Stress on the central incisor (model 1). Fig. 4. Stress on the prostheses (model 1). Fig. 7. Stress on the prostheses with attachment (model 2).

4 S. JIAN et al. Fig. 8. Stress on the remaining teeth (model 2). conventional von Mises stress pattern in the obturator prosthesis with extracoronal attachment and the remaining teeth (model 2). The palatal stress for the two designs was both located in the anterior area and adjacent to the defect (Figs 4 and 7). The highest stress value of model 1 and mole 2 was 13Æ1, 19Æ9 Mpa respectively. For both models, stress distribution was uniform in the remaining posterior teeth with almost the same stress value, which were relatively higher than that in the anterior teeth (Figs 5 and 8). The highest stress value of model 1 and mole 2 was 11Æ25, 11Æ38 Mpa respectively. And at the central incisor region adjacent to the attachment, an area of stress concentration was found at the mesial surface of the central incisor, with a maximum stress value of 1Æ306 Mpa (Fig. 9). While for model 1, it was also found that the mesial surface of the central incisor, with a maximum stress value of 0Æ582 Mpa (Fig. 6). As for the continuous lingual guide plane with attachment, the stress concentrations were found at the junction of the attachment and the lingual guide plane and the anterior part of the lingual plane, especially at the position between canine and premolar. And the maximum stress value was 10Æ7 Mpa (Fig. 10). Discussion Fig. 9. Stress on the central incisor (model 2). Fig. 10. Stress on the lingual guide plane with attachment. Because of the inadequate prosthesis support in the maxillectomy patient, stress distribution to both the palate and the remaining teeth is optimal for the health of the remaining structures. Based upon the findings of this study, for both models, stress concentration was seen in the anterior area of the palate and the remaining teeth, especially the posterior teeth, which also supports the findings found in previous studies (5, 8). However, the highest stress value of model 2 was higher than that of model 1 by about 6Æ8 Mpa. On one hand, these findings all demonstrate that the design of the obturator attachment framework in this study are in accordance with the established design principles for the restoration of maxillary defects. On the other hand, it was also indicated that more consideration should be taken into to preserve the remaining structures as much as possible when attachment framework was applied.

FEA OF MAXILLARY OBTURATOR WITH ATTACHMENT 5 Stress concentration was also seen at the junction of the attachment and the lingual guide plane and the anterior part of the lingual guide plane, which may reduce the life of the abutment and cause adhesion failure. This occurrence could be explained by the creation of a dynamic fulcrum line during loading. The maximum stress value in the lingual guide plane was 10Æ7 Mpa, which was lower than adhesive strength of acid-etched enamal resin (16 20 Mpa) and yield strength of the chrome cobalt alloy(692 Mpa), according to the literature (9). And it was also found that the maximun value of the central incisor with attachment was almost twice as that of in model one. Therefore, it is suggested to splint the two incisors together. It is also strongly recommended that rest seats must be developed to allow the stress to be transferred to the long axis of the abutment (1, 2, 5, 8). To accommodate for the obturator and reduce the stress on the abutment teeth, it is suggested that a resilient attachment be selected (1, 2). The Mini-SG F attachment used in this study has nylon washer between the male and female parts which not only can give a cushion effect but also be easily changed to maintain the retentive force due to wear. In this study, a continuous lingual guide plane from the central incisor to the second molar with an attachment on central incisor was designed. The use of attachment on the tooth adjacent to the defect can provide adequate retention and better aesthetics of the prosthesis. The purpose of guide plane was not only to modify the abutment contours, but more importantly to serve as splint. This kind of design may prolong the life of the abutment and lead to a successful prosthodontic rehabilitation for maxillary defect. Acknowledgment This study was supported by grant of Shanghai Education Committee (04BC40) and Shanghai Leading Academic Discipline Project (T0202). References 1. Taylor T. Clinical maxillofacial prosthetics. Chicago, IL: Quintessence Publishing Co; 2000: 53 61. 2. Grossmann Y, Madjar D. Resin-bonded attachments for maxillary obturator retention: a clinical report. J Prosthet Dent. 2004;92:229 232. 3. Sigurgeirsdottir E, Minsely GE, Rothenberger SL. Incorporation of an ERA attachment for obturator framework design: a clinical report. J Prosthet Dent. 2002;87:477 480. 4. Talor T, Gerrow J, Brudvik J. Resin-bonded components for maxillafacial prosthesis construction: a clinical trial. J Prosthet Dent. 1988;59:334 339. 5. Lyons KM, Beumer J III, Caputo AA. Abutment load transfer by removable partial denture obturator frameworks in different acquired maxillary defects. J Prosthet Dent. 2005;94:281 288. 6. Fiebiger GE, Rahn AO, Lundquist DO, Morse PK. Movement of abutments by removable partial denture frameworks with a hemimallectomy obturator. J Prosthet Dent. 1975;34:555 561. 7. Parr GR, Tharp GE, Rahn AO. Prosthodontic principles in the framework design of maxillary obturator prostheses. J Prosthet Dent. 1989;62:205 212. 8. Myers R, Mitchell D. A photoelastic study of stress induced by framework design in a maxillary resection. J Prosthet Dent. 1989;61:590 594. 9. O Brien WJ. Dental materials and their selection. Hanover Park, IL: Quintessence Publishing Co; 2002: 71, 232. Correspondence: Dr Jiao Ting, Department of Prosthodontics, School of Stomatology, Ninth People s Hospital, Shanghai Jiaotong University, Zhi Zhao Ju Road 639, Shanghai 200011, China. E-mail: jiao_ting@hotmail.com