Universal Plunger Loc Attachment

Similar documents
Preci Clix Instructions for Ball Retained Overdenture Attachments

Preci Clix Instructions for Ball Retained Overdenture Attachments

FR Attachment Instructions Removable Partial Dentures

OT EQUATOR CASTABLE Single Attachment for Overdentures

UDELL DENTAL LABORATORY Instructions for Use

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Table of Contents. Flexi-Overdenture Characteristics

Hex-Lock Abutment System. Restorative Manual

Use of the Sicat Surgical Guide In Reconstruction of the Hemi-Mandilectomy Patient

SimpleLine II Surgical / Prosthesis Manual

How something small, can make such a big difference!! Your best choice in overdenture

UDELL DENTAL LABORATORY Instructions for Use AND ERA-RV

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

VIP Partner Laboratory (PL) Process Flow

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

SS Implant System 2013 PROSTHETIC PROCEDURE

SURVEYING OF REMOVABLE PARITAL DENTURES FEB, 11, 2015

DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009

Element-Z Screw-Retained Hybrid

immediate implantation and loading with Paltop Osteotomes for bone expansion Case Study

STEP-BY-STEP-ANLEITUNG

Diagnosis 220 Temporary Filling Carrier. Periodontics Periodontal Curette / Sharpener

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Dowel restorations Treatment with a post and core

Steri-Oss Compatible Components

2. Gap closure and replacement of the missing tooth 35 with directly modelled bridge region 34-36

SCD Case Study. Attachments in Prosthodontics

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

Even faster thanks to ExpertEase Immediate restoration directly following implant placement. new

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

Implant Phase Flow Chart

Prosthetic V. Removable dentures I.

verification jig fabrication

Flexi-Flange Fiber. Instruction Book for Flexi-Flange Fiber Posts IMPORTANT: Read pages 7 through 12 for Technique first. ESSENTIAL DENTAL SYSTEMS

ball abutment overdenture: chairside pick-up using existing denture

For Threadloc 3.75 (implant discontinued - components available in Branemark section) For Spline SD, RD & WD (only Locator components available)

Removable Partial Dentures

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

Steps in construction of an interim dental implant-supported hybrid prosthesis:

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

IMPRESSION PROCEDURES TRAINING MANUAL

CHECK-UP Determination of Impression type & Method after implant placement

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

Attachments and Pre-fabricated Castable Components

Restoring Straumann implants. with Locator abutments.

US Implant System 2013 PROSTHETIC PROCEDURE

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

LOCATOR ROOT ATTACHMENT SYSTEM

The Relining Method of Removable Denture with Magnetic Attachments

/NobelReplace Ø4.3mm. /NobelReplace Ø3.5mm

Prosthodontic Procedure

In 1977, Lew1 developed a passive

SKELETAL PROTHESIS with Vertys Prothesis Excel / Plus heat-curing resin

SuperLine & Implantium Surgical / Prosthesis Manual

Invisible Retainer with Multi-Tooth Pontic Fabrication Technique (Single-Tooth Pontic Procedure also available)

Guided surgery manual

Leading material offering and application range. Straumann CARES CADCAM

Product Catalog. Since 1985» Simple. Predictable. Profitable.

External Hex 4.1 & 5.0 platform

أ.م. هدى عباس عبد اهلل CROWN AND BRIDGE جامعة تكريت كلية. Lec. (2) طب االسنان

Relining and Rebasing of complete denture

The number of totally edentulous

Shadeguides Ceramic Veneers: Tooth Preparation for Enamel Preservation

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

Implant Restorations: A Step-By-Step Guide

IMPLANT - Abutment made of titanium - Crown - Metal - Retentive abutment shape - Posterior tooth - SpeedCEM Plus

Legacy Prosthetic Catalog

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

LABORATORY PROCEDURES, STEP BY STEP

cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

OD Secure chairside pick-up using existing denture

INTRODUCTION. Why Choose Cortex Prosthetics?

Watson Dental Lab Fixed Hybrid Protocol

50 Shades of Teflon Part 1

Conus Concept: A Rewarding Complete Denture Treatment

UNDERSTANDING DIGITAL DENTISTRY: CBCT AND INTRA-ORAL 30 SCANNING

Astra Tech Implant System. Manual and product catalog. Guided surgery. Computer guided implant treatment with the Astra Tech Implant System EV

Protemp Crown Temporization Material

Laser Assembled and CAD/CAM Prosthetic Frameworks for the Debilitated Mandible. Robert Schneider, DDS, MS

Full Arch Rehabilitation All-on-4 Technique Restorative Steps Recipe for Success

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Construction of Removable Partial Denture

Bridge. For more detailed information, please check the Immediate Smile bridge guidelines.

Prosthodontic Procedure

PARTIAL MOBILE DENTURE with Vertys Prothesis Excel / Plus termo-polimerizing resin

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Chapter 12. Prosthodontics

Universal IC Attachment

Extraction with Immediate Implant Placement and Ridge Preservation in the Posterior

ARAB AMERICAN UNIVERSITY. Lab. Manual. Prosthetic Dentistry1; Removable Prosthodontics. 3 rd year

- RESTORATIVE PRODUCT CATALOG

Lect. 14 Prosthodontics Dr. Osama

SuperLine & Implantium Surgical / Prosthesis Manual

Invisible Retainer with Single-Tooth Pontic Fabrication Technique (Multi-Tooth Pontic Procedure also available)

Advanced restorative techniques and the full mouth reconstruction: the use of gold copings in bridgework

Selection and arrangement of teeth in rpd

Prosthodontic Procedure

Transcription:

Universal Plunger Loc Attachment www.preat.com 800-232-7732 Universal Plunger Loc Complete Universal 7.5mm length TI plunger attachment. Compatible with Lew Passive and Swiss Loc NG. 1.5mm plunger, 7.5mm long, may be reduced to 4mm in length. Plunger Tip 2mm long. Complete attachment comes with extra delrin insert to allow easy servicing. Universal Plunger Loc Processing Jig Processing Jig. Sold individually. Plunger Tip 3.4mm long Universal Plunger Loc Male Only Titanium plunger with Plastic insert

Universal Plunger Loc Twist Drill. Applications Removable prosthetics such as Bar Overdentures, Removable Telescopic Crowns and Bridges, and Partial Dentures. Specifications Housing Diameter = 2.9mm Plunger/Pin Diameter = 1.5mm The pin diameter of the Universal Plunger Lock Attachment is the same as the SwissLoc NG and the Lew Passive Attachments. Length = 7.5mm, but may be reduced to 4mm. Length is measured from head of plunger to end of housing in a closed position. Material: Titanium Note: **Do not pull the plunger pin out of the housing. Pulling the plunger pin out of the housing will destroy the internal plastic sleeve. If the plunger pin has been pulled out of the housing, it needs to be replaced by a new pin. **The Universal Plunger Lock attachment is titanium and therefore not suitable for casting. Polymerize into acrylic resin, or bond into a secondary structure. **When reducing the length of the Universal Plunger Loc, cut at slow speeds or with water coolant to avoid generating heat and damaging the plastic insert. Technique

For removable partial dentures, wax the crown as usual. A milled lingual support arm and rest is designed into the abutment tooth crown. Wax--or place a pre-formed 0 degree, 1mm thick plastic pattern as holder for the Universal Plunger Lock attachment. For overdenture bar constructions, use a 1.5mm reamer to pre-drill a hole into plastic or gold bar extension. Use a 1.5mm carbide to place the hole in titanium bar structures. Utilize a silicone matrix of the tooth set-up to verify the position of the bar pattern as well as to determine the proper length of attachment needed. After try-in and a passive bar fit verified, seat the wax denture over the bar. Make horizontal access holes in the buccal flange for processing jigs. Wax-up completely around the processing jigs. Flask the completed set-up, making sure that the processing jig is indexed in plaster/stone, and boil out. Wax-up completely around the processing jigs. Flask the completed set-up, making sure that the processing jig is indexed in plaster, and boil out.

Seal any gaps around the processing jig and bar with liquid latex or Rubber Sep. Block out all undercuts as well as all attachments, cylinders, and screws. Block out the bar occlusally if resilient function is desired. Process acrylic. When processing on a master cast, do not remove the denture until the attachments are cured into position. When processing on a duplicate cast, the denture may be removed, finished, and then seated on the master cast. Remove the processing jigs by turning and pulling with pliers. Apply heat to the jigs to facilitate removal. Place the Universal Plunger Lock attachments into the access hole created by the processing jigs. The attachments should fit loosely inside the access hole; however, acrylic may be reduced to facilitate placement. Place the attachments all the way into the hole of the bar. The housing of the attachment should be flush with the buccal acrylic.

To shorten the attachment, pull the plunger into an open position and cut the plunger and housing together with a diamond disk. Cut at SLOW SPEEDS and/or with water coolant to avoid distorting the plastic plunger insert. Before placing the attachment back into the access hole, with the attachment in a closed position, carefully seal the exit point of the plunger and housing with soft wax. The wax will prevent self-curing acrylic from getting inside the attachment. Seal any gaps between the attachment and bar, if necessary.

Insert the attachment back into the access hole of the buccal flange and all the way into the bar access hole. Make sure the attachment is fully seated, and apply runny auto-polymerizing acrylic around the retentive housing in the access hole. Cure in a pressure pot. After curing, pull the plunger to an out position and finish the acrylic around the attachment. Create a slight mesial depression in the acrylic to facilitate removal by the patient. The tip of the plunger pin may also be rounded and smoothed to facilitate insertion by the patient. Secondary Structure Fabrication On the master cast, place the processing jigs into the holes in the primary structure. Check for proper positioning and relieve undercuts. A thin layer of vaseline may be placed on the jigs to make removal of the pattern of secondary structure easier. Wax the secondary structure, adding retentions. Remove the pattern, check for fit on the primary structure, and make any adjustments needed. Once the secondary structure is cast and finished, it should have a friction fit with the primary structure. The horizontal access hole should be visible through both the primary and secondary structures. Acrylic is processed in the usual manner, placing the processing jig in through the secondary and fully seated inside the hole in the primary structure.

A 1:1 mixture of Ceka site may be used to bond the Plunger Lock attachment into the framework, or the attachments may be picked up with a runny mixture of self curing acrylic. Servicing Servicing the Universal Plunger Loc is very simple. If you need to replace a male plunger, or if a male plunger at any time has been removed entirely from the metal housing, a new Plastic Insert is required. Remove the broken plastic from the male plunger, and use an explorer or like instrument to remove the remaining plastic from inside the metal housing. Push the narrow end of the plastic insert into the metal housing and then push the metal male plunger into the housing/insert. A second plastic housing is now included with all Universal Plunger Loc attachments to facilitate servicing. T0110.REV.06