Yong Un Shin, 1,2 Mincheol Seong, 1,2 Hee Yoon Cho, 1,2 and Min Ho Kang 1,2. 1. Introduction

Similar documents
Sutureless Intrascleral Pocket Technique of Transscleral Fixation of Intraocular Lens in Previous Vitrectomized Eyes

Temporary Haptic Externalization and Four-point Fixation of Intraocular Lens in Scleral Fixation to Enhance Stability

Clinical Study The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

Intrascleral-fixated intraocular lenses for aphakic correction in the absence of capsular support

Visual outcome and early complications of sutureless and glueless scleral fixated intraocular lens

2/26/2017. Sameh Galal. M.D, FRCS Glasgow. Lecturer of Ophthalmology Research Institute of Ophthalmology

Capsule fixation device for cataract surgery

In the absence of capsular support, the ophthalmic

COURSE DESCRIPTION BASIC FUNDAMENTALS

We describe a new surgical technique for treating traumatic aniridia with aphakia

IOL Subluxation Top 5 Pearls for Management. Disclosure. David G. Hwang, MD, FACS. Shire Consultant. Not relevant to this talk.

SURGICAL OUTCOME OF SIMULTANEOUS INTRAOCULAR LENS RESCUE AND SUTURELESS INTRASCLERAL TUNNEL FIXATION OF DISLOCATED INTRAOCULAR LENSES

Inadvertent trypan blue staining of posterior capsule during cataract surgery associated with "Argentinian flag" event

Net technique for intraocular lens support in aphakia without capsular support

INTRODUCTION. Trans Am Ophthalmol Soc 2007:105:

Combined 23-gauge transconjunctival vitrectomy and scleral fixation of intraocular lens without conjunctival dissection in managing lens complications

Comparing safety and efficiency of two closed-chamber techniques for iridodialysis repair - a retrospective clinical study

Research Article The Impact of the Menstrual Cycle on Perioperative Bleeding in Vitreoretinal Surgery

Pediatric traumatic cataract Presentation and Management. Dr. Kavitha Kalaivani Pediatric ophthalmology Sankara Nethralaya Nov 7, 2017

SPONTANEOUS, LATE, IN-THE-BAG IOL DISLOCATION: ETIOLOGY, RISK FACTORS, PREVENTION, AND MANAGEMENT

Electronic poster presentations

Case Report Osteolysis of the Greater Trochanter Caused by a Foreign Body Granuloma Associated with the Ethibond Suture after Total Hip Arthroplasty

Case Report Reverse Segond Fracture Associated with Anteromedial Tibial Rim and Tibial Attachment of Anterior Cruciate Ligament Avulsion Fractures

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

Navigating the Options for the Treatment of Intraocular Lens Malposition

Unilateral Scleral Fixation of Posterior Chamber Intraocular Lenses in Pediatric Complicated Traumatic Cataracts

Brijesh Takkar 1, Shorya Vardhan Azad 1, Neelima Aron 1, Ravi Bypareddy 1, Rajvardhan Azad 2. Introduction

BAG-TO-THE-WALL TECHNIQUE FOR A SUBLUXATED LENS

Modified Technique of Four Point Scleral Sutured Posterior Chamber Intraocular Lens Without Scleral Flaps

Surgical management of non-traumatic pediatric ectopia lentis: A case series and review of the literature

Clinical Study Patient Aesthetic Satisfaction with Timing of Nasal Fracture Manipulation

Plate/Valve Specifications: Thickness: 0.9mm Width: 13.00mm Length: 16.00mm Surface Area: mm 2

Optometric Postoperative Cataract Surgery Management

CONSENT FOR CATARACT SURGERY REQUEST FOR SURGICAL OPERATION / PROCEDURE AND ANAESTHETIC

Cataract surgery is the leading cause of malpractice claims (OMIC) Complicated CE/IOL: Choices the anterior segment surgeon can make

Late Intraocular Lens Subluxation in Patients with Uveitis

Case Report An Undescribed Monteggia Type 3 Equivalent Lesion: Lateral Dislocation of Radial Head with Both-Bone Forearm Fracture

Innovative Iris Repair

Trauma. steve charles

Clinical Evaluation of the BunnyLens IOL

WGA. The Global Glaucoma Network

Case Report Detached Anterior Horn of the Medial Meniscus Mimicking a Parameniscal Cyst

Clinical Study Air Bubble Technique for Fundus Visualization during Vitrectomy in Aphakia

Title. with prior vitrectomy. Author(s) Takashi. Issue Date Wichtig Editore.

GLUED PC IOL IMPLANTATION WITH INTRALAMELLAR SCLERAL TUCK IN EYES WITH DEFICIENT CAPSULE

GLUED PC IOL IMPLANTATION WITH INTRALAMELLAR SCLERAL TUCK IN EYES WITH DEFICIENT CAPSULE

POSTTRAUMATIC WHITE CATARACT

Non Phaco Sutureless Cataract Surgery with Small Scleral Tunnel Incision Using Rigid PMMA IOLS

Case Report A Case Report of Isolated Cuboid Nutcracker Fracture

Available online at Int. J. Modn. Res. Revs. Volume 3, Issue 10, pp , October, 2015

Case Report Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

JasonC.S.Yam, 1 Gabriela S. L. Chong, 2 Patrick K. W. Wu, 2 Ursula S. F. Wong, 2 Clement W. N. Chan, 2 and Simon T. C. Ko 2. 1.

SPONTANEOUS, LATE, IN-THE-BAG IOL DISLOCATION: Continuous curvilinear capsulorhexis, phacoemulsification and in-the-bag placement of

Mechanics of the Ahmed Glaucoma Valve

Long-term Outcomes of Vitreous Floaters Management with 23-Gauge Transconjunctival Sutureless Vitrectomy

84 Year Old with Rosacea

A patient with dropped nucleus and intraocular lens

Case Report Complete Obstruction of Endotracheal Tube in an Infant with a Retropharyngeal and Anterior Mediastinal Abscess

Anterior segment imaging

Subject Index. Canaloplasty aqueous outflow system evaluation 110, 111 complications 118, 119 historical perspective 109, 110

SECONDARY CAPSULOTOMY USING THE FEMTOSECOND LASER. Surendra Basti, MD Northwestern University Feinberg School of Medicine, Chicago, IL

Clinical Study Open Reduction of Subcondylar Fractures Using a New Retractor

PRECISION PROGRAM. Injection Technique Quick-Reference Guide. Companion booklet for the Video Guide to Injection Technique

Case Report Pediatric Transepiphyseal Seperation and Dislocation of the Femoral Head

Repositioning a glaucoma drainage device tube from the anterior chamber to the ciliary

Research Article Predictions of the Length of Lumbar Puncture Needles

Management of Congenital Cataract Surgery. Dr. Vaishali Vasavada, MS. Dr. Abhay R. Vasavada, MS, FRCS (England) Raghudeep Eye Hospital, India

Nature and Science 2016;14(9)

Objectives. Tubes, Ties and Videotape: Financial Disclosure. Five Year TVT Results IOP Similar

A new surgical technique for scleral fixation using a knot ball for scleral-fixated intraocular lenses: impact on clinical outcomes

Original Article Capsular tension ring implantation after lens extraction for management of subluxated cataracts

EndoGlide Ultrathin Surgical Pearls Prof. Donald Tan

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal

Endo Optiks. Clinical Publication Summaries

Slide 1. Slide 2. Slide 3. An EK For All Reasons: When and How to Perform DSAEK and DMEK. Financial Disclosure

STAB INCISION GLAUCOMA SURGERY (SIGS)

Clinical Study Changing Trends in Use of Laparoscopy: A Clinical Audit

Subnormal Vision in Uneventful Cataract Surgery after 6 Weeks Hospital Based Study

Conjunctival displacement to the corneal side for oblique-parallel insertion in 25-gauge vitrectomy

Baris Beytullah Koc, 1 Martijn Schotanus, 1 Bob Jong, 2 and Pieter Tilman Introduction. 2. Case Presentation

The Ultima foldable scleral fixation intraocular lens: A 2-year follow-up

OVERVIEW OF OCULAR MANAGEMENT IN MARFAN SYNDROME

Original Article. Address for Correspondance Dr. Charu Mithal Upgraded Dept. of Ophthalmology, LLRM Medical College Meerut.

Basic microsurgical suturing techniques for beginners

Clinical Study Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

Combined Cataract Surgery on a Marfan-syndrome Patient (Case report)

Refractive Dilemma. Challenging Case

Original article. Amon M Pediatric micro-incision cataract surgery Nepal J Ophthalmol 2011;3(5):3-8

DIAGNOSTIC AND SURGICAL TECHNIQUES

Astigmatism outcomes of scleral tunnel and clear corneal incisions for congenital cataract surgery

Posterior Chamber Intraocular Lens Implantation in Pediatric Cataract with Microcornea and/or Microphthalmos

Learn Connect Succeed. JCAHPO Regional Meetings 2015

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

An Injector s Guide to OZURDEX (dexamethasone intravitreal implant) 0.7 mg

Start with ME. LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL

No-Touch Technique and a New Donor Adjuster for Descemet s Stripping Automated Endothelial Keratoplasty

Cataract Surgery: Patient Information

Synchrony AIOL Key Features

Clinical Study Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas

II Ophthalmic Spring Academy. May 20 th -24 th 2014 Cracow, Hotel Galaxy

Transcription:

Hindawi Ophthalmology Volume 2017, Article ID 2683415, 4 pages https://doi.org/10.1155/2017/2683415 Research Article Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman s Knot Yong Un Shin, 1,2 Mincheol Seong, 1,2 Hee Yoon Cho, 1,2 and Min Ho Kang 1,2 1 Department of Ophthalmology, Hanyang University College of Medicine, Seoul, Republic of Korea 2 Department of Ophthalmology, Hanyang University Guri Hospital, Guri, Republic of Korea Correspondence should be addressed to Min Ho Kang; ocularimmunity@gmail.com Received 21 March 2017; Accepted 27 June 2017; Published 31 July 2017 Academic Editor: Lisa Toto Copyright 2017 Yong Un Shin et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Purpose. To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman s knot (SFK). Methods. First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. Results. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage) was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. Conclusions. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique. 1. Introduction Long-term safety of sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) implantation is an important issue for surgeons. IOL dislocations by spontaneous breakage of 10-0 polypropylene sutures have been reported [1 3]. To avoid material problems that arise from these sutures, the 9-0 polypropylene suture or Gore-Tex has been recommended as an alternative for sutured scleral fixation of PC IOL [3 5]. Curved long needles (CIF-4, Ethicon) or straight long needles (STC-6, Ethicon) are commonly used for sutured scleral fixation. However, the types of needles that can attach to a 9-0 polypropylene suture are in limited supply in Asia and many other regions; CIF-4 and STC-6 needles are not available. In addition to Ethicon products, a 9-0 polypropylene suture is available on long curved or straight needles from Visionary Medical Supplies (Madison, USA), but it is not available either in Asia or in other regions. As an alternative, a simple needle-and-hook apparatus was proposed to achieve the same effect as the STC6 needle with the 9-0 polypropylene suture [5]. Sutureless scleral fixation of the IOL can be another solution, but this technique requires vitrectomy instruments and additional surgical experience [6]. We previously suggested a simple method to restore a fractured 10-0 polypropylene suture using a single fisherman s knot (SFK) [4]. The SFK can be used to join two lines

2 Ophthalmology with a symmetrical structure consisting of two overhand knots, each tied around the standing part of the other; it has sufficient knot security and is simple to perform. We introduce this clinically useful and simple SFK method to be used with 9-0 polypropylene sutures to overcome the nonavailability of a long needle 9-0 polypropylene suture. 2. Patients and Methods Patients who needed the scleral fixation of IOL because of the absence of sufficient capsular structure to support the intraocular lens were included. Surgical results are retrospectively reviewed via chart review. The preoperative and postoperative visual acuity, corneal astigmatism, and corneal endothelial cell count and intraoperative and postoperative complications were evaluated. The study was approved by the Hanyang University Guri Hospital s ethics committee. 3. Surgical Techniques After peribulbar or retrobulbar anesthesia, localized peritomy was performed at the appropriate site. A single-arm, straight (STC-6, Ethicon), or curved needle (CIF-4, Ethicon) with a 10-0 polypropylene suture was passed through the sclera 1 1.5 mm behind the limbus using the ab externo technique, and the suture was pulled from the opposite cornea wound. The ends of the 10-0 and 9-0 polypropylene sutures were overlapped, where they were joined. The unpassed end of the 10-0 polypropylene suture was tied to the 9-0 polypropylene suture using an SFK (Figures 1(a), 1(b), and 1(c)). Next, the 10-0 polypropylene suture was pulled to allow the SFK to pass through the sclera (Figure 1(d)). The SFK was removed from the anterior chamber through the corneal or scleral wound for IOL insertion (Figure 1(e)), the 10-0 polypropylene suture was cut off at the SFK, and the 9-0 polypropylene suture was used to close the knot (Figure 1(f), see Supplementary Video available online at https://doi.org/10.1155/2017/2683415, which shows the surgical procedure for Figures 1(a), 1(b), 1(c), 1(d), 1(e), and 1(f)). Repeating the same method, another 9-0 polypropylene suture was tied to the haptic of the IOL (Figure 1(g)). The surgeon can choose any IOL type that is clinically available. To avoid knot exposure, we used a Z-suture technique to fix the haptic to the sclera [7]. 4. Results An SFK joining 10-0 and 9-0 polypropylene sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL were included in this study. Seven patients were female (20%), and 28 were male (80%); the average patient age at the time of surgery was 63.2 ± 8.6 years (2 SD) (range, 51 83 years). The preoperative mean uncorrected visual acuity was 20/300. The preoperative mean corneal astigmatism was 1.30 ± 1.27 diopters, and the preoperative endothelial cell density ranged from 1266 3265 cells per square millimeter (mean, 2217.3 ± 626.2 cells/mm2). Postoperative mean uncorrected visual acuity, postoperative mean corneal astigmatism, and postoperative mean endothelial density were 20/60, 1.34 ± 0.86 diopters, and 1944.8 ± 683.2 cells/mm2, respectively (p < 0 001, p = 0 853, and p =002). An intraoperative complication (minor intraocular hemorrhage during needle passage) was recorded in four cases. Postoperative complications, such as knot exposure, IOL dislocation, subluxation, and retinal detachment, were not observed. 5. Discussion Sutureless scleral fixation of the IOL is a new technique for overcoming the common weaknesses of sutured scleral fixation, which include spontaneous breakage, knot exposure, and IOL position problems [6, 8]. However, sutureless scleral fixation of the IOL requires posterior segment instruments and a machine for pars plana vitrectomy. Manipulation of the haptic to pull it through the sclerotomy can cause physical damage to the haptic and can compromise the long-term stability of the IOL. Intraoperative breakage or haptic deformity requires removal and reinsertion of the IOL [9]. Additionally, the risk of exposure of the haptic through the sclera cannot be ruled out. Many authors have reported that no complications related to the use of the sutureless technique arose in the short term, but long-term outcomes were not reported [10]. Even the scleral-sutured knot, which should be buried by the scleral flap, can be exposed through the scleral flap and the conjunctiva [11]. An intrastromal fixated haptic has sustained tension to the sclera, and the thickness of the sclera flap is similar to that of the flap of a sutured scleral-fixated IOL. Thus, an intrastromal haptic can erode over the sclera and conjunctiva. Sutured scleral-fixated IOLs will continue to be a widely used option for managing IOL dislocation without IOL exchange, because dislocated IOLs are not always available in three pieces. In such cases, IOL exchanges are necessary in order to perform a sutureless scleral fixation. And it is difficult to handle the IOL haptics in the anterior chamber of severely damaged eyes. Furthermore, each surgeon has a different set of surgical skills and instruments, and we cannot ignore that operation results are affected by surgeon proficiency. Sutured scleral-fixated IOLs with 10-0 polypropylene sutures can break spontaneously, so a thicker 9-0 polypropylene suture is more suitable for long-term stability. But the available needles are not varied enough (e.g., straight, curved, short, and long) to meet the needs of these new techniques. By using an SFK, a surgeon can use a familiar needle type, and except for making a knot, surgeons do not need additional surgical instruments or techniques. Also, ciliary sulcus fixation can be advantageous for haptic adhesion by the fibrous membrane to the ciliary body for long-term stability [12 14]. However, the larger knots made by 9-0 polypropylene sutures could erode externally through the scleral flap, exposing the patient to a higher risk of endophthalmitis. To

Ophthalmology 3 (a) (b) (c) (d) (e) (f) (g) Figure 1: Surgical technique to prepare the 9-0 polypropylene suture using a single fisherman s knot with a 10-0 polypropylene suture: (a) overlap the ends of the 10-0 and 9-0 suture lines and make a loop with the 9-0 suture around the 10-0 suture. (b) Make a knot around the 9-0 suture and pull the standing lines in opposite directions to slide the two knots together using a single fisherman s knot (SFK). (c) After clipping the ends near the knot, (d) pull the opposite 10-0 suture to pass the SFK with the 9-0 suture. (e, f) Remove the SFK in the anterior chamber through the corneal or scleral wound for IOL insertion, and cut off the 10-0 suture with the SFK. (g) By repeating the same method, another 9-0 suture was prepared to be tied to the haptic of the IOL. (a) (b) Figure 2: The shapes of the two different knots: the single fisherman s knot (SFK) and the double figure eight knot: (a) the SFK is a smaller knot size compared with the double figure eight knot and is aligned with the standing part. (b) The double figure eight knot is a larger knot size than the SFK and is at the right angle to the standing part. prevent knot erosion, a Z-suture technique is a good solution that does not involve scleral flaps or grooves [7]. Another simple method for making a line-to-line knot is to make a double figure-eight knot. However, the double figure-eight knot is bigger than the others and is at a right angle to the standing part, which increases friction as it passes through the tissue (Figure 2). However, the SFK is smaller than the double figure-eight knot and is aligned with the standing line, so it can pass through the sclera with a low friction coefficient. The nonavailability of a long needle 9-0 polypropylene suture has restricted the application of the 9-0 polypropylene suture in Asia and other regions to prevent knot breakage in the sutured scleral fixation of IOL. The SFK is very easy to perform, is a useful method for overcoming the nonavailability of a long needle 9-0 polypropylene suture by connecting

4 Ophthalmology the two lines from the 10-0 and 9-0 polypropylene sutures, and is small enough to pass through the sclera without breakage or slippage. Conflicts of Interest No conflicting relationships exist for any of the authors. Acknowledgments This work was supported by the Research Fund of Hanyang University (HY-2015). chamber lenses, American Ophthalmololgy, vol. 123, no. 3, pp. 411 413, 1997. [13] M. L. McDermott and J. E. Puklin, Pars plana cicatrization of sewn-in posterior chamber intraocular lens haptics, Ophthalmic Surgery and Lasers, vol. 28, no. 3, pp. 239-240, 1997. [14] M. Kuchle, B. Seitz, C. Hofmann-Rummelt, and G. O. Naumann, Histopathologic findings in a transsclerally sutured posterior chamber intraocular lens, Cataract Refractive Surgery, vol. 27, no. 11, pp. 1884 1888, 2001. References [1] R. Asadi and A. Kheirkhah, Long-term results of scleral fixation of posterior chamber intraocular lenses in children, Ophthalmology, vol. 1, no. 1, pp. 67 72, 2008. [2] E. G. Buckley, Safety of transscleral-sutured intraocular lenses in children, American Association for Pediatric Ophthalmology and Strabismus, vol. 12, no. 5, pp. 431 439, 2008. [3] M. O. Price, F. W. Price Jr., L. Werner, C. Berlie, and N. Mamalis, Late dislocation of scleral-sutured posterior chamber intraocular lenses, Cataract Refractive Surgery, vol. 31, no. 7, pp. 1320 1326, 2005. [4] M. H. Kang, M. Seong, H. W. Lim, and H. Y. Cho, Simple method to restore a fractured 10-0 polypropylene suture using a single fisherman's knot, Cataract Refractive Surgery, vol. 40, no. 9, pp. 1568 1570, 2014. [5] M. W. Stewart and M. B. Landers 3rd, Transscleral intraocular lens fixation with a "homemade" needle and hook, Journal of Cataract Refractive Surgery, vol. 32, no. 2, pp. 200 202, 2006. [6] A. Agarwal, D. A. Kumar, S. Jacob, C. Baid, A. Agarwal, and S. Srinivasan, Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules, Cataract Refractive Surgery, vol. 34, no. 9, pp. 1433 1438, 2008. [7] P. Szurman, K. Petermeier, S. Aisenbrey, M. S. Spitzer, and G. B. Jaissle, Z-suture: a new knotless technique for transscleral suture fixation of intraocular implants, British Ophthalmology, vol. 94, no. 2, pp. 167 169, 2010. [8] S. G. Gabor and M. M. Pavlidis, Sutureless intrascleral posterior chamber intraocular lens fixation, Cataract Refractive Surgery, vol. 33, no. 11, pp. 1851 1854, 2007. [9] Y. Benayoun, S. Petitpas, K. Turki, J. P. Adenis, and P. Y. Robert, Sutureless scleral intraocular lens fixation: report of nine cases and literature review, Franch Ophthalmology, vol. 36, no. 8, pp. 658 668, 2013. [10] D. A. Kumar, A. Agarwal, S. Packiyalakshmi, S. Jacob, and A. Agarwal, Complications and visual outcomes after glued foldable intraocular lens implantation in eyes with inadequate capsules, Cataract Refractive Surgery, vol. 39, no. 8, pp. 1211 1218, 2013. [11] K. Solomon, J. R. Gussler, C. Gussler, and W. S. Van Meter, Incidence and management of complications of transsclerally sutured posterior chamber lenses, Cataract Refractive Surgery, vol. 19, no. 4, pp. 488 493, 1993. [12] E. J. Holland, A. R. Djalilian, and J. Pederson, Gonioscopic evaluation of haptic position in transsclerally sutured posterior

MEDIATORS of INFLAMMATION The Scientific World Journal Gastroenterology Research and Practice Diabetes Research International Endocrinology Immunology Research Disease Markers Submit your manuscripts at https://www.hindawi.com BioMed Research International PPAR Research Obesity Ophthalmology Evidence-Based Complementary and Alternative Medicine Stem Cells International Oncology Parkinson s Disease Computational and Mathematical Methods in Medicine AIDS Behavioural Neurology Research and Treatment Oxidative Medicine and Cellular Longevity