apneabp card(x)plore ABPM-04 Ambulatory Blood Pressure Monitors & Combinations

Similar documents
Device Equivalence Evaluation Form

BP Hour Ambulatory Blood Pressure Monitor. Medical Diagnostic Device

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.

Device Equivalence Evaluation Form

SOMNOcheck micro CARDIO. Simple Assessment of Cardiovascular Risk During Sleep. In sleep medicine In internal medicine In preventive medicine

Introducing the WatchPAT 200 # 1 Home Sleep Study Device

Obstructive sleep apnoea How to identify?

DECLARATION OF CONFLICT OF INTEREST

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form

Where experience connects with innovation

AGING, BLOOD PRESSURE & CARDIOVASCULAR DISEASE EVENT RISK. Michael Smolensky, Ph.D. The University of Texas Austin & Houston

Ambulo Ambulatory Blood Pressure Monitoring Systems. Innovative Diagnostics Better Care

Sleep diagnostics systems

Automated Blood Pressure Monitor

High Risk OSA n = 5,359

Ambulatory BP Monitoring: Getting the Diagnosis of Hypertension Right. Anthony J. Viera, MD, MPH, FAHA Professor and Chair

Device Equivalence Evaluation Form

STATE OF THE ART BP ASSESSMENT

Dear, Respectfully, United Sleep Centers SLEEP STUDY DATE: FEBUARY 26, 2015 AT OUR DOWNEY CENTER TIME: 10PM, PLEASE ARRIVE ON TIME

Importance of Ambulatory Blood Pressure Monitoring in Adolescents

Obstructive Sleep Apnea Syndrome. Common sleep disorder causes high blood pressure and heart attacks

Diabetes & Obstructive Sleep Apnoea risk. Jaynie Pateraki MSc RGN

AMBULATORY BLOOD PRESSURE REPORT. Patient Name: Sample 2 - Systolic Hypertension Patient ID: Test Date: 15-Sep-2005

GETTING THE NUMBERS RIGHT: ACCURATE MEASUREMENT OF BLOOD PRESSURE

Primary hypertension in adults

Blood Pressure Measurement Does it matter where you do it or how often?

International Journal of Scientific & Engineering Research Volume 9, Issue 1, January ISSN

The Agony or the Ecstasy. Familiar?

Management of OSA in the Acute Care Environment. Robert S. Campbell, RRT FAARC HRC, Philips Healthcare May, 2018

WHAT YOU NEED TO KNOW ABOUT SLEEP APNEA

Rediscover the power of sleep

Effective Treatment for Obstructive Sleep Apnoea

BP210 BP250. Automatic Blood Pressure Monitor. Medical Diagnostic Device

Dräger Alcotest 5510 Alcohol Screening Device

Balboa Island Dentistry (949)

Cardiocap/5. GE Healthcare. The compact, all-in-one, critical care monitor. Features. Available options

80 Appendix A. Fig. A.1 Repository of ABPM information containing measurements of the BP

In-Patient Sleep Testing/Management Boaz Markewitz, MD

Non-contact Screening System with Two Microwave Radars in the Diagnosis of Sleep Apnea-Hypopnea Syndrome

sleepview by midmark Home Sleep Test

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION*

Relax, you re in safe hands EMBLETTA MPR

ROBERT C. PRITCHARD DIRECTOR MICHAEL O. FOSTER ASSISTANT DIR. SLEEP APNEA

Effective Treatment for Obstructive Sleep Apnoea

ABPM screen 300/400 Risk Assessment

(To be filled by the treating physician)

Simple diagnostic tools for the Screening of Sleep Apnea in subjects with high risk of cardiovascular disease

Web-Based Home Sleep Testing

Relax, you re in safe hands

SLEEP APNOEA DR TAN KAH LEONG ALVIN CO-DIRECTOR SLEEP LABORATORY SITE CHIEF SDDC (SLEEP) DEPARTMENT OF OTORHINOLARYNGOLOGY, HEAD & NECK SURGERY

THN. Sleep Therapy Study. ImThera. Information for Participants. Caution: Investigational device. Limited by United States law to investigational use.

White coat and masked hypertension

Helping You to Breathe Better, Sleep Easy & Live Well

Tired of being tired?

ECG MACHINE KEC- Series

PC-BASED ECG SYSTEMS

Sleep Quiz & Referral Form Inside

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

Helping You to Breathe Better, Sleep Easy & Live Well

Ultimate Solution. for Healthy Life. HANBYUL Overview

OSA and COPD: What happens when the two OVERLAP?

TECHNOCARE MEDISYSTEMS

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

Declaration of Equivalence Form

OSA - Obstructive sleep apnoea What you need to know if you think you might have OSA

Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls

13. Blood Pressure. Millie Grim Geek Rea New Zealand

Coding for Sleep Disorders Jennifer Rose V. Molano, MD

Rigel UNI-SiM Lite. The most cost-effective patient simulator on the market. Key Features n Compact and cost-effective

Sleep Medicine. Paul Fredrickson, MD Director. Mayo Sleep Center Jacksonville, Florida.

Questions: What tests are available to diagnose sleep disordered breathing? How do you calculate overall AHI vs obstructive AHI?

Obstructive Sleep Apnoea. Dr William Man Thoracic and Sleep Medicine, Harefield Hospital

Development of a portable device for home monitoring of. snoring. Abstract

From a screener to a full PSG System in the palm of your hand Upgradeable at any time!

The most accurate predictors of arterial hypertension in patients with Obstructive Sleep Apnea Syndrome

A GUIDE TO OUR NIBP TECHNOLOGY

Natural performance. Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being

Snoring and Sleep Apnea

By utilizing VirtuOx IDTF and our VPOD line of Overnight Pulse Oximeters your center will:

BTS sleep Course. Module 10 Therapies I: Mechanical Intervention Devices (Prepared by Debby Nicoll and Debbie Smith)

Assessment of Sleep Disorders DR HUGH SELSICK

Neurostyle. Medical Innovation for Better Life

Observations on Sleep Apnoea and Cardiac disease

UIHC Home Sleep Apnea Testing (HSAT)

Biomedical Instrumentation E. Blood Pressure

SLEEP STUDY. Nighttime. 1. How many hours of sleep are you now getting in a typical night?

Sleep History Questionnaire B/P / Pulse: Neck Circum Wgt: Pulse Ox

WRHA Surgery Program. Obstructive Sleep Apnea (OSA)

2017/8/23 1. SE-2003&SE-2012 Holter Analysis System

Rigel UNI-SiM. The world s smallest integrated NiBP, SpO2 and patient simulator. Key Features n Compact and cost-effective

Rest Stop #101. Sleep & Fatigue-What s the difference and what to do about it.

Supplementary Online Content

A New, Clinically Proven Sleep Apnea Therapy for people unable to use CPAP.

Sleep and the Heart. Physiologic Changes in Cardiovascular Parameters during Sleep

Sleep and the Heart. Rami N. Khayat, MD

ASK US. A Study for Obstructive Sleep Apnea Patients Using a New At-Home Sleep Test ARE YOU ABOUT THE STUDY #

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN?

Medicare CPAP/BIPAP Coverage Criteria

Transcription:

apneabp card(x)plore ABPM-04 Ambulatory Blood Pressure Monitors & Combinations

Meditech Cardiovascular Monitoring Solutions Meditech is one of the worldwide technology leaders in the area of manufacturing ambulatory blood pressure monitors and ECG devices. Established in 1990 by Hungarian private entrepreneurs, Meditech develops medical devices and software solutions for monitoring risk factors for cardiovascular diseases.

apneabp ABPM, SpO 2 & Actigraphy Combo Obstructive sleep apnea syndrome (OSAS), a sleep-related breathing disorder, is an independent risk factor for hypertension. Early recognition and treatment improves cardiovascular functions. Meditech apneabp is suitable for screening OSAS and hypertension in primary care. Consequences of Undiagnosed Sleep Apnea 10-32x increase in cardiovascular mortality 15-20x increase in sleep-related traffic accidents 7-10x increase in cerebrovascular mortality OSAS symptoms extreme snoring drowning nightmares daytime sleepiness morning headaches resistant hypertension stroke rithm disturbances apneabp benefits complex ABPM profile complex pulse oximetry profile complex actigraphy & body position profile pulse waveforms & pulse transition times free, all-inclusive software

ABPM-04 Ambulatory BP Monitor ABPM-04 provides accurate information on blood pressure variability, overnight dipping and morning surge for reliable hypertension control. ABPM-04 benefits meets BHS and AAMI accuracy criteria, recommended by dabl proprietary Meditech dual-valve system for excellent patient safety sleep-friendly algorithm free, all-inclusive software Why ABPM is needed? for a more accurate BP profile to avoid the effects of white coat hypertension to record nighttime BP, a major health risk indicator to lower the chance of misdiagnosis for better drug treatment

card(x)plore ABPM, Holter ECG & Actigraphy Combo As hypertension is the most common risk factor for cardiovascular diseases, it is important to assess blood pressure and ECG data at the same time. card(x)plore benefits complex ABPM profile complex Holter ECG profile complex actigraphy & body position profile quick identification of exceeded limit values with extra BP recordings free, all-inclusive software

Specifications dimensions weight (excl. batteries) memory data transfer power supply LCD display numbers of keys operation ABPM analysis Holter ECG analysis apnea analysis actigraphy conformity certificate validations ABPM-04 card(x)plore apneabp internal up to 51 hrs 124*82*33,5 mm 250g external (a card reader unit is needed for retrieving data) USB optical cable 4 AA batteries 20*8 mm 2 (start, event) measurement method: oscillometric; measurement range: 30-260 mmhg, pulse: 40-200 bpm; passive accuracy: +/- 3 mmhg or 2% of the measured value 3 channels (7 leads); sampling: 600 HZ; A/D resolution: 12 bit; storage: 300 Hz SpO 2 sampling, measurement range & accuracy: 4 beat average, 0-100%, +/- 3% (70-100% SpO 2 ); plethysmograph sampling & measurement range: 75 Hz with automatic sensitivity setting 2-axis; sampling: 10 Hz; sensitivity: 0,01g CE algorithm validated to BHS & AAMI protocols up to 27 hrs

Specifications dimensions weight (excl. batteries) memory data transfer power supply LCD display numbers of keys operation ABPM analysis Holter ECG analysis apnea analysis actigraphy conformity certificate validations ABPM-04 card(x)plore apneabp internal up to 51 hrs 124*82*33,5 mm 250g external (a card reader unit is needed for retrieving data) USB optical cable 4 AA batteries 20*8 mm 2 (start, event) measurement method: oscillometric; measurement range: 30-260 mmhg, pulse: 40-200 bpm; passive accuracy: +/- 3 mmhg or 2% of the measured value 3 channels (7 leads); sampling: 600 HZ; A/D resolution: 12 bit; storage: 300 Hz SpO 2 sampling, measurement range & accuracy: 4 beat average, 0-100%, +/- 3% (70-100% SpO 2 ); plethysmograph sampling & measurement range: 75 Hz with automatic sensitivity setting 2-axis; sampling: 10 Hz; sensitivity: 0,01g CE algorithm validated to BHS & AAMI protocols up to 27 hrs

2015KA02/UK Meditech Ltd 1184 Budapest, Mikszáth Kálmán u. 24. phone: +36 1 280 8232, +36 1 280 8233 mail: meditech@meditech.eu www.meditech.eu