Preci Clix Instructions for Ball Retained Overdenture Attachments

Similar documents
Preci Clix Instructions for Ball Retained Overdenture Attachments

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

Height* FC width Prep depth RC width 4.0mm+ 4.3mm N/A 6.3mm

Universal Plunger Loc Attachment

OT EQUATOR CASTABLE Single Attachment for Overdentures

UDELL DENTAL LABORATORY Instructions for Use

Table of Contents. Flexi-Overdenture Characteristics

LOCATOR ROOT ATTACHMENT SYSTEM

UDELL DENTAL LABORATORY Instructions for Use AND ERA-RV

ball abutment overdenture: chairside pick-up using existing denture

FR Attachment Instructions Removable Partial Dentures

Hex-Lock Abutment System. Restorative Manual

How something small, can make such a big difference!! Your best choice in overdenture

Legacy Prosthetic Catalog

OD Secure chairside pick-up using existing denture

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

eliminate interlocking with new QUick Up method

SS Implant System 2013 PROSTHETIC PROCEDURE

SimpleLine II Surgical / Prosthesis Manual

Restoring Straumann implants. with Locator abutments.

Attachments and Pre-fabricated Castable Components

Implant Phase Flow Chart

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

Removable Partial Dentures

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Steps in construction of an interim dental implant-supported hybrid prosthesis:

US Implant System 2013 PROSTHETIC PROCEDURE

Lect. 14 Prosthodontics Dr. Osama

ZEST DANVILLE MATERIALS PERIOSCOPY

Z5mlc (Locator *) Implants

Conus Concept: A Rewarding Complete Denture Treatment

Trabecular Metal and Tapered Screw-Vent Implant Systems. Restorative Manual

cement-retained single crowns using cementable abutments

PROSTHETIC COMPONENTS

Chapter 12. Prosthodontics

SCD Case Study. Attachments in Prosthodontics

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

Removable partial dentures

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

Ankylos. Product Catalog

CHECK-UP Determination of Impression type & Method after implant placement

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Construction of Removable Partial Denture

Occlusal Splint Fabrication Technique

4766 Research Dr. San Antonio, TX insightdentalsystems.com

WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP.

SuperLine & Implantium Surgical / Prosthesis Manual

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

Essentials of. Dental Assisting. Edition 6. Debbie S. Robinson Doni L. Bird

Quick Up. Self-curing luting material for attachments and secondary components in dentures

prosthetic technique manual

INTRODUCTION. Why Choose Cortex Prosthetics?

STEP-BY-STEP-ANLEITUNG

SlimLine Product Catalog & Manual 1. Unit:mm, Scale 1: 1.5 / mm. SlimLine. Product Catalog / Manual

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

SuperLine & Implantium Surgical / Prosthesis Manual

SURVEYING OF REMOVABLE PARITAL DENTURES FEB, 11, 2015

LOCATOR abutment and collar for VARIOmulti

LOCATOR ATTACHMENT SYSTEM TECHNIQUE MANUAL

FIXED-HYBRID EMERGENCY! Why Redo When You Can Rescue?

WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP. NO SCREWS. NO CEMENT. NO COMPROMISES.

Protemp Crown Temporization Material

2018 MEDIHELP RATES - 54 PRACTICE Kindly see below Tariffs for Medihelp. Please note that not all tariff codes listed are covered by the respective

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

Immediate loading and implant surgery with digital workflow

ARAB AMERICAN UNIVERSITY. Lab. Manual. Prosthetic Dentistry1; Removable Prosthodontics. 3 rd year

IMPRESSION PROCEDURES TRAINING MANUAL

Product Ordering Information

SCD Case Study. Implant-supported overdentures

Whole You Denture CP IOD Impression/Try-in/Final Delivery Manual

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM TECHNIQUE MANUAL

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

Product Catalog. Since 1985» Simple. Predictable. Profitable.

A perfect fit for ultimate comfort. Soft and Extra Soft

ORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

TS Implant System 2013 PROSTHETIC PROCEDURE

Straumann Mini Implant System Basic Information. Technical Information

NARROW DIAMETER implant

A new technique for preprosthetic restorations.

The Relining Method of Removable Denture with Magnetic Attachments

OPENING MINDS AND EXPANDING PRACTICE REVENUE OPPORTUNITIES

Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution 3.0 License.

Stainless Steel Crowns

CATALOG. Since 1985» Simple. Predictable. Profitable.

RETIREE DENTAL PLAN. RETIREE DENTAL PLAN FEE SCHEDULE Page 1 of 8

IMPRESSION TECHNIQUE AND MATERIALS

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

Invisible Retainer with Multi-Tooth Pontic Fabrication Technique (Single-Tooth Pontic Procedure also available)

Austenal PermaSoft Soft Denture Liner

Astra Tech Implant System. Attachment-retained restorations. Clinical and laboratory procedures OsseoSpeed TX

DL 313 Removable Partial Dentures II

Implant Esthetic Failure

1- Implant-supported vs. implant retained distal extension mandibular partial overdentures and residual ridge resorption. Abstract Purpose: This

Flexi-Flange Fiber. Instruction Book for Flexi-Flange Fiber Posts IMPORTANT: Read pages 7 through 12 for Technique first. ESSENTIAL DENTAL SYSTEMS

Prosthodontic Rehabilitation with Overdenture Using Modified Impression Technique: A Case Report

The REAL Mini Implant

Transcription:

www.preat.com 800-232-7732 Preci Clix Instructions for Ball Retained Overdenture Attachments Dentist Direct Placement Technique In one appointment, an existing removable partial denture may be converted to a Preci Clix retained overdenture. Benefits o o o o Economical: Inexpensive components; no lab fees. Efficient: Simple and Easy to fabricate and service. Small Size: 2.25mm Ø sphere -- total vertical space required is 4.0mm Reduced Wear: easy insertion and removal with the ability to parallel the females with non-parallel males. 1227, 1228, 1229 burs 1291C titanium Post RE H2 RE H14 to prepare root seating and impression tool female analogue

Screwdriver for male 1206C Male Large Tin Spacer 1251B Space Maintainer 1222 Insertion Tool Female Retention Caps Yellow=standard White = reduced Orange = increased Metal Housing for female retention caps Ceka Bond Adhesive to prevent gradual unthreading of males.

Preci Clix Instructions for Ball Retained Overdenture Attachments 1 2 3 Preparing the Root and Placing the Post: Following the endodontic treatment, the canal is prepared with the 1227 predrilling bur( Fig 1). The 1228 cavity bur is used next to prepare the canal for the base of the 1291 post ( Fig 2). Finally, the 1229 precision reamer is used to calibrate the canal for the diameter of the 1291 post (Fig 3). When using the burs, proceed at slow speeds, avoiding horizontal forces. 6 5 4 Figure 4 shows the prepared root. Thread the RE H2 impression tool into the Preci Clix post (Fig 5) Using the RE H2 seating and impression tool as a handle, place the Preci Clix post into the canal and check the fit (Fig 6).

8 9 7 Sandblast the Preci Clix Post prior to cementation. The RE H2 tool will protect the threads from cement (FIG 7-8). Cover the post and root surface with bonding composite. Seat the post. After the composite is set, polish the root surface with a fine sandpaper disk. Topical fluoride is often used to prevent decay (Fig 9). Laboratory Processing of the Female Attachments 1 Taking Impression: 2 Leave the RE H2 in the cemented post, and make final impression. The RE H2 (Fig 1) will make an index in the impression. Unthread the REH2 from the post, and thread it in to the RE H14 model analogue (FIG 2). Index the RE H2/RE H14 in the impression (Fig2) and pour the master model (FIG 3 ).

3 4 Processing the Female: The RE H14 will be indexed in this model--exactly where the post and basering is in the mouth. (Fig3). Unthread the RE H2 from the RE H14 that is indexed in the stone model. Use the Preci Clix screwdriver to thread the titanium Preci Clix 1206C threaded ball into the RE H14 (Fig4).. Important: Use the large tin spacer The large tin spacer is used over the attachment during processing to block out excess acrylic from locking in the attachment. The main reason for using the big spacer may be understood by viewing figures A and B. A Ceka overdenture attachment is used as an example. A B Ceka attachment used for example Ceka attachment used for example Figure A is an overdenture fabricated without the large spacer. This eliminates all movement of the prosthesis- -it is a rigid attachment. As you can see, the denture base is in direct contact with the post and attachment (arrow). Forces are directed to the post and attachment. Figure B is the same overdenture, only this time the large spacer was used. Using the large spacer allows for

movement of the prosthesis--it is now a resilient (tissue bearing) attachment. During processing, the large spacer creates a free space between the prosthesis and the post and attachment to allow this free movement, and direct forces to the tissue. The greater the area the forces are spread over, the less force that is generated on the abutment. 5 6 7 Place the tin spacer over the male. Next place the 1251B black rubber space maintainer over the large tin spacer and Preci Clix 1206C Ball on the model (Fig 7 ). Figure5 shows the placement of the Preci Clix female into the Clix housing using the 1222 Clix insertion tool. Placing the metal housing upside down on a flat surface makes seating the female easier. Place the complete female unit onto the Clix ball on the model (please note the 1251B space maintainer--fig 6 ). Block out any undercuts. Process the Clix female into the denture. 9 10 8 Remove both the large tin spacer and black rubber spacer. Remove the Preci Clix threaded male from the model using the Clix screwdriver. Send the prosthesis, screwdriver, and Clix threaded males to the Dentist. In the operatory, put a drop of Ceka Bond on the male threads before threading it into the Clix Post (Fig 8). This will prevent gradual unthreading of the threaded male. Figure 9 shows the finished prosthesis. Figure 10 shows the 3 different retentions of Preci Clix females: standard retention (yellow), decreased retention (white), and increased retention (orange).

Option 2: Chairside Pick-Up of the Female Attachments Direct Placement by the Dentist 2 Put a drop of Ceka Bond on the male threads before threading it into the Clix Post. This will prevent gradual unthreading of the threaded male. Thread the ball in to the post in the mouth. Blockout Option 1, Tin Spacer: Place a large tin spacer over the ball and contour the pliable tin spacer around the ball and gingiva. You may need to cut a slot in the tin spacer for easier adaptation. Option 2, Rubber Dam: place a piece of rubber dam over the ball and surrounding area. Place the small black spacer over the ball, and seat the complete female (housing and plastic insert). Use the Clix insertion tool to snap the plastic insert into the housing. Parallel

To compensate for divergent abutments, it is simple to parallel the Clix females. Rotate the housing around the sphere until the flat top of the housings have the same draw. This can be done chairside with any flat instrument, like a tongue depressor, or in the Laboratory with the Clix Female Paralleling Mandrel. Pickup After setting the Clix housings in a parallel position, blockout any additional undercuts with material of choice, such as Perma Block. Relieve the denture to receive the Clix housings. Make sure that the denture can fully seat without any premature contact between the housings and the denture. Use a small round bur to cut escape vents from the relieved area out to the lingual of the denture. These lingual escape vents will eliminate the lifting or hydraulic effect of autopolymerizing acrylic resin, as well as provide an "escape" for any excess acrylic.

It is preferable that excess acrylic flows to the lingual instead of underneath the attachments! After cutting the lingual escape vents, prime the existing acrylic with monomer. Place a low viscous mix of self curing acrylic resin into the relieved area of the denture, and seat the denture with finger pressure only on the attachment area. Do not have the patient come into full occlusion and displace soft tissue in the saddle area. This will cause the prosthesis to cant, or rotate anterior to posterior, and take the attachments out of alignment. The prosthesis is seated in the mouth for approximately 6 minutes, or what the acrylic resin manufacturer indicates. Remove any excess resin as well as the tin spacer and black rubber spacer. Finish and polish. The female may be easily changed in the metal housing to adjust retention. Instruct the patient in the path of insertion. Have the patient insert and remove the appliance several times. T0034.REV.03