Reliability of linear distance meas. Wakoh, M; Harada, T; Otonari, T; Ot. Journal Bulletin of Tokyo Dental College, 4

Similar documents
The Effect of X Ray Vertical Angulation on Radiographic Assessment of Alveolar Bone Loss

The treatment protocol for replacing

The Effect of Bite Registration on the Reproducibility of Parallel Periapical Radiographs Obtained with Two Month Intervals

The diagnosis of periodontal disease is greatly facilitated

Cone-beam CT (CB Throne) applied to Title dentomaxillofacial region. Yajima, A; Otonari-Yamamoto, M; San. Yonezu, H; Nakagawa, K; Yajima, Y

Monday Morning Pearls of Practice by Bobby Baig

Computed tomography for dental implants: the influence of the gantry angle and mandibular positioning on the bone height and width

Implant Imaging JCD /jp-journals REVIEW ARTICLE ABSTRACT

Reliability of Orthopantomography and Cone-beam Computed Tomography in Presurgical Implant Planning: A Clinical Study

Assessment of Response of Dental Clinicians and Patients towards Different Imaging Modalities Used In Diagnostic Evaluation of Dental Implant Therapy.

Mædica - a Journal of Clinical Medicine. Interobserver variability of the diagnosis of apical periodontitis on panoramic radiography assessment

PALATAL POSITIONING OF IMPLANTS IN SEVERELY RESORBED POSTERIOR MAXILLAE F. Atamni, M.Atamni, M.Atamna, Private Practice Tel-aviv Israel

University of Groningen

Sang-Sun Han, 1 Kwang-Min Lee, 2 and Kee-Deog Kim Introduction

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

The Egyptian Journal of Hospital Medicine (July 2013) Vol. 52, Page

Radiographic Methods for the Detection

Dental Implant Treatment with Diffe Title for Sinus Floor Elevation-A Case Re. Sekine, H; Taguchi, T; Seta, S; Tak Author(s) T; Kakizawa, T

Dental Implants: A Predictable Solution for Tooth Loss. Reena Talwar, DDS PhD FRCD(C) Oral & Maxillofacial Surgeon Associate Clinical Professor

Implant envision for the dentist

The majority of the early research concerning

Osseointegrated dental implant treatment generally

Dr. Muhannad Abdulrhman Muhammed Halwani, Rakan Saed Safar Al Thobaiti and Abdallah Ali M Asker

POST-IMPLANT NEUROLOGICAL COMPLICATIONS IN THE HORIZONTAL MANDIBULAR ARCH

The Application of Cone Beam CT Image Analysis for the Mandibular Ramus Bone Harvesting

Karl Maloney, DDS,* Jairo Bastidas, DMD, Katherine Freeman, DrPH, Todd R. Olson, PhD, and Richard A. Kraut, DDS. Materials and Methods

Dental Implant Planning using Cone Beam CT imaging: a pictorial guide.

Assessment of the relationship between the maxillary molars and adjacent structures using cone beam computed tomography

Evaluation of proximity of the floor of the maxillary. Zanco J. Med. Sci., Vol. 16, No. (2), 2012

The advent of computerized tomography (CT) greatly

E.A.O. Guidelines for the use of Diagnostic Imaging in Implant Dentistry

Immediate implant placement in the Title central incisor region: a case repo. Journal Journal of prosthodontic research,

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

The influence of sensor size and orientation on image quality in intra-oral periapical radiography

Diagnostics and treatment planning. Dr. Attila Szűcs DDS

Digital Implant Dentistry Workflow

The morphological studies of root r maxillary primary canines and their Title the position of successive permanen Micro-CT

CHAPTER 6. Zygogiannis K Aartman IHA Parsa A van der Stelt PF Wismeijer D. Accepted

The Quality Leader in 3D Cone Beam CT

Computerized Tomographic Localization of Inferior Alveolar Canal and Mental Foramen in the Mandible Among Implant Patients:An Imaging Study.

THREE-DIMENSIONAL COMPUTED TOMOGRAPIDC ANALYSIS FOR PLACEMENT OF MAXILLOFACIAL IMPLANTS AFTER MAXILLECTOMY

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

In vitro cone beam computed tomography imaging of periodontal bone

COMPUTER TOMOGRAPHY ASSESSMENT OF ALVEOLAR RIDGE MODIFICATIONS IN ELDERLY PATIENTS

CT Scan Technology. An Evolving Tool for Avoiding Complications and Achieving Predictable Implant Placement and Restoration SCOTT D.

CBCT as an Emerging Gold Standard for Presurgical Planning in Implant Restorations

Periapical radiography and cone beam computed tomography for assessment of the periapical bone defect 1 week and 12 months after root-end resection

Assessment of the relationship between maxillary sinus floor and maxillary posterior teeth root apices using spiral CT scan

Measurements of the mandibular canal by multidetector computed tomography

International Journal of Current Medical and Pharmaceutical Research

Oral Health and Dentistry

Digital Imaging from a new perspective

The influence of radiotherapy on osseointegration

The Brånemark osseointegration method, using titanium dental implants (fixtures)

Original Research Article

Assessment of Lingual Concavities in Submandibular Fossa Region in Patients requiring Dental Implants A Cone Beam Computed Tomography Study

Comparison of accuracy of digital radiography and panoramic radiography in dental implants procedure - A literature review

Periapical Radiography

CBCT Specific Guidelines for South African Practice as Indicated by Current Literature:

anatomy in 71 cadavers.

Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines

Radiographic Evaluation of Bone Formation and Density Changes after Mandibular Third Molar Extraction: A 6 Month Follow up

A rare crestal branch of inferior alveolar nerve: case report 1 Mahdi Niknami 1 Reza Es haghi * 2 Hamed Mortazavi 3 Hadi Hamidi

Distribution of the maxillary artery related to sinus graft surgery for implantation

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

Evaluation of a Digital Measurement Tool to Estimate Working Length in Endodontics

Extraoral Imaging. Chapter 42. Copyright 2018, Elsevier Inc. All Rights Reserved. 1

Rehabilitation of atrophic partially edentulous mandible using ridge split technique and implant supported removable prosthesis

CPD Article ISSUE 59. Proud of our History, Looking Forward to the Future

BONE AUGMENTATION AND GRAFTING

Extraoral Radiology October 10th, 2008

Digital Radiograph Registration and Subtraction: A Useful Tool for the Evaluation of the Progress of Chronic Apical Periodontitis

In-Office Cone Beam Computerized Tomography: Technology Review and Clinical Examples Michael Tischler, DDS

Assessing the Anatomical Variations of Lingual Foramen and its Bony Canals with CBCT

Alveolar Growth in Japanese Infants: A Comparison between Now and 40 Years ago

Much has been written about the success of various

Yokose, T; Sakamoto, T; Sueishi, K; Author(s) Tsujino, K; Kubo, S; Yakushiji, M; Journal Bulletin of Tokyo Dental College, 4

/TLv/ A classification of the edentulous jaws. Trauma; Preprosthetic Surgery. iiiii!iii!iii! ] BASAL

Title. Author(s)Matsushita, Kazuhiro; Yamamoto, Hidekazu. CitationBritish journal of oral and maxillofacial surgery, 5. Issue Date

Treatment planning in a case of restoration of the maxilla and mandible using osseointegrated implants with four types of bone graft

SEDENTEXCT: Guidelines and evidence-based use of CBCT

Visibility of Maxillary and Mandibular Anatomical Landmarks in Digital Panoramic Radiographs: A Retrospective Study

Introduction. Clinical Periodontal Examination 11/1/16

High Crown to Implant Ratio as Stress Factor in Short Implants Therapy

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

Root Proximity Characteristics and Type of Alveolar Bone Loss: A Case-control Study

Pre-operative evaluation of the volume of bone graft in sinus lifts by means of CompuDent

The effect of peri-implant bone exposure on soft tissue healing and bone loss in two adjacent implants

Endosseous dental implants initially showed very

JSOMR X-0001:2015 (OID: )

Clinical details: Details of scan: CONE BEAM CT REPORT: Name: H. B. Gender: Reason for referral: Referred by:

THE USE OF KEYSTONE EASYGUIDE CT SCANNING SOFTWARE FOR DIAGNOSIS, DIRECTION AND DEPTH DETERMINATION

Comparison of Conventional and Standardized Bone Densitometry around Implants in Periapical Radiographs during a Three Months Period

DENTAL RADIOLOGY Identify basic facts and terms of radiology, to include fundamentals. with 70% accuracy.

Evaluation of cancellous bone density in the alveolar bone by cone-beam computed tomography in Taiwanese adults

Normal Radiographic Anatomy Maxillary Central Area

Esthetic management of multiple missing anterior teeth A Case report

Cephalometric Analysis

Bone Reduction Surgical Guide for the Novum Implant Procedure: Technical Note

Keywords: Mandible, Maxilla, Teeth, Cone Beam CT, Implants, Tumor and tumor-like conditions

Transcription:

Reliability of linear distance meas Titledental implant length with standard radiographs Wakoh, M; Harada, T; Otonari, T; Ot Author(s) M; Ohkubo, M; Kousuge, Y; Kobayashi Kitagawa, H; Sano, T Journal Bulletin of Tokyo Dental College, 4 URL http://hdl.handle.net/10130/225 Right Posted at the Institutional Resources for Unique Colle Available from http://ir.tdc.ac.jp/

Bull Tokyo Dent Coll (2006) 47(3): 105 115 105 Original Article Reliability of Linear Distance Measurement for Dental Implant Length with Standardized Periapical Radiographs Mamoru Wakoh, Takuya Harada, Takamichi Otonari, Mika Otonari-Yamamoto, Mai Ohkubo, Yuji Kousuge*, Norio Kobayashi*, Shigeru Mizuta**, Hiromi Kitagawa*** and Tsukasa Sano Department of Oral and Maxillofacial Radiology, Tokyo Dental College, 1-2-2 Masago, Mihama-ku, Chiba 261-8502, Japan * Department of Radiology, Tokyo Dental College, Chiba Hospital, 1-2-2 Masago, Mihama-ku, Chiba 261-8502, Japan ** Apple Dental Clinic, 2568-6 Anegasaki, Ichihara 299-0111, Japan *** Yakuendai Station Dental Clinic, 6-1-1-2E Yakuendai, Funabashi 274-0077, Japan Received 2 August, 2006/Accepted for publication 15 September, 2006 Abstract The purpose of this study was to investigate the accuracy of distance measurements of implant length based on periapical radiographs compared with that of other modalities. We carried out an experimental trial to compare precision in distance measurement. Dental implant fixtures were buried in the canine and first molar regions. These were then subjected to periapical (PE) radiography, panoramic (PA) radiography, conventional (CV) and medical computed (CT) tomography. The length of the implant fixture on each film was measured by nine observers and degree of precision was statistically analyzed. The precision of both PE radiographs and CT tomograms was closest at the highest level. Standardized PE radiography, in particular, was superior to CT tomography in the first molar region. This suggests that standardized PE radiographs should be utilized as a reliable modality for longitudinal and linear distance measurement, depending on implant length at local implantation site. Key words: Dental implant length Radiography Measurement accuracy Mandible Introduction Radiographs are an important tool for assessment of bone architecture. Radiographs are used to evaluate bone support at the recipient site of a dental implant at each of the three phases of implant treatment, evaluation, and maintenance. The first phase consists of pre-surgical assessment of bone amount at potential implant recipient sites during treatment planning. The second phase comprises pre- and intra-surgical assessment 105

106 Wakoh M et al. of surrounding anatomical structures, which mainly include distance from alveolar crest to mandibular canal and mental foramen in mandible, and to the floor of the maxillary sinus, nasal cavity and the incisal canal in the maxilla 3,13,14). This measurement value is useful in selecting and estimating the length of implant fixtures. The final use of radiographs is in longitudinal assessment of bone loss, which is a characteristic of the success or failure of implant therapy. Unfortunately, no technique truly satisfies the ideal goal of supporting all assessments at each phase 7). In an attempt to achieve such an ideal radiographic assessment, a clinician often combines multiple radiographic techniques. Beason et al. 4) researched the types of radiographic modalities used for pre-operative implant site assessment, and the results showed that more than 95% of dentists took panoramic (PA) radiographs. Sakakura et al. 21) also reported that over approximately 80% of dentists took PA radiographs, either as a single examination or in combination with periapical (PE) radiographs. Their results showed that only about 10% preferred the combination of computed (CT) or conventional (CV) tomography with other types of radiographic methods. When pre- and intra-surgical assessment for dental implant performance is focused on the linear measurement of distance in bone, routine PA radiographs 14,20,24), cross-sectional radiographs reconstructed from routine PA radiographic data 18), and CV 9,14,25) or CT tomographs 5,9,17,20,25) including reformatted crosssectional images as the occasion arises have been used. Most previous research has compared precision of measurement, mainly involving the distance from the alveolar crest to adjacent anatomical structures, among these various modalities, together with crosssectional images in which the information acquisition of not only mesio-distal but also bucco-lingual and superior-inferior direction of the jaw bone is possible. Few studies have evaluated precision on PE radiographs compared with that on other radiographs. It may be because cross-sectional images are not available for PE radiographs. Additionally, periapical radiographs have the limitation that adjacent anatomical structures, such as mandibular canal and the floor of maxillary sinus, may not be visible on a film due to the smallness of the area involved. Meanwhile, for longitudinal assessment of bone loss after implantation, measurement is based on the implant length. The length of the natural tooth root is unknown, whereas the implant length is known before implantation. If the bone height relative to the implant fixture after implantation is expressed as a percentage of the implant length, it may be easily converted into a millimeter measurement of the bone loss present as the longitudinal assessment. In other words, the implant fixture itself acts as its own ruler to compensate for linear measurement of bone loss. Although digital subtraction technique 8,11,12,27,28) with PE radiographs has recently become widely used for bone loss assessment, and most dentists in private clinics routinely use PE radiographs for implant site assessment, no studies have reported the accuracy of linear measurement of implant length based on PE radiographs compared with that on other radiographs. The purpose of this paper is to compare precision of measurement of implant length among the current radiographic modalities used for implant performance, and to consequently demonstrate the reliability of PE radiographs for lateral and linear measurement of implant length. Materials and Methods A dried skull was prepared for the placing of dental implants in the mandible of which images using each imaging modality were to be taken. We used two dental implant fixtures: ultrathin-hydroxyapatite (HA)-coated implants made by the thermal decomposition method (Platon Implant Japan, Tokyo), respectively measuring 17.37 mm and 13.56 mm in actual length. The former and the latter were respectively buried at the canine and the first molar tooth region in the right mandible (Fig. 1). They were then exposed to each

Implant Length Measurement on Radiographs 107 Fig. 1 Objects used to obtain sample images with each imaging modality imaging modality, including PE and PA radiography, CV and medical CT tomography. In PE radiography, paralleling technique was used with the XCP instrument (Rinn, Elgin, USA) in order to maintain correct positioning of the dental film (Fig. 2A). The Xspot-TW (Asahi Roentgen, Kyoto, Japan) was used as the dental x-ray apparatus. The Veraviewepocs (Morita Corp., Kyoto, Japan) was used in PA radiography. The Frankfort plane (FP) or the occlusal plane (OP) of the dry skull were positioned parallel to a laser light beam, which was set to flow parallel to the floor. The laser was provided as part of the apparatus itself. Images were then taken in each of these positions (Fig. 2B). For CV tomography, an OPTIPLANIMAT unit (Siemens) was used. To obtain precise tomographic images of the implant fixture, the direction of the laser light beam was made aligned with the long axis of the implant fixture on each region (Fig. 2C). For medical CT tomography, SOMATOM Plus4 (Siemens) was used. First, the dried skull was fixed in the standard position using a head fixing bracket, positioning the occlusal plane perpendicular to the floor, after which, axial images were obtained. Successive crosssectional images (CS1) of each region were respectively reconstructed using the dental- CT software program, referring to the axial CT tomographic image obtained (Fig. 2D-a). Furthermore, another cross-sectional image (CS2) aligned with the long axis of the implant fixture in each region, taking into account the direction of the implantation of the implant fixture, was respectively reconstructed together with a parasagittal image (Fig. 2D-b). Length of implant fixture was individually measured on each film by nine observers who were oral and maxillofacial radiologists. Each observer measured each film 3 times. The results were expressed as a mean rating s.d. for each modality group, and subjected to the Kruskal-Wallis and Scheffe s multiple comparison non-parametric test. Additionally, intra- and inter-observer reproducibility was also calculated for each modality group using a one-way factorial ANOVA. A value of p 0.05 was regarded as significant. The software for the statistical analysis was StatView J 4.02 (Brain Power Inc., Agoura Hills, USA). Results Figures 3A and 3B respectively show the mean rating (R s.d.) for measurement of implant fixture on each image in the canine and molar regions. The Kruskal-Wallis test showed that there was a significant difference between the mean ratings for each regional group (canine region, p 0.0001; molar region, p 0.0001). This significant difference in measurement accuracy among the various imaging modalities in each group was further clarified with the Scheffe s multiple comparison test. The statistical result is shown in Table 1. In the canine region, this test showed no significant difference between PE radiograph and CT tomogram as CT-CS1 (p 0.1847) or CT-CS2 (p 0.1175). In the molar region, this test showed no significant difference between PA radiographs positioned based on FP and OP (p 0.8010), or between CT-CS1 and CT- CS2 images. Figures 4 and 5 respectively show the mean rating (R s.d.) of measurement

108 Wakoh M et al. A B Fig. 2 by each observer group for each modality in the canine and molar regions. Table 2 shows the results for variance of measurement data between inter- and intra-observer for each modality, which were expressed as a mean square. In each modality group, variance for intra-observer was smaller than that for interobserver, except with PE radiographs. F-value was also extremely small for PE radiographs. Discussion A vast amount of radiographic imaging

Implant Length Measurement on Radiographs 109 C D Fig. 2 Positioned landscapes of dried skull, and radiographs (inclusive of exposure process in CT) obtained for measuring in each modality A: PE, B: (a) PA-FP, (b) PA-OP, C: CV, D: (a) CT-CS1, (b) CT-CS2

110 Wakoh M et al. Fig. 3 A Comparing measuring distance of implant fixture among imaging modality groups in canine (A) and molar (B) regions B Table 1 p-values obtained with Scheffe s multiple comparison test for each imaging modality PA-FP PA-OP CV CT-CS1 CT-CS2 PE 0.0001 0.0001 0.0001 0.1847 0.1175 PA-FP 0.0053 0.0001 0.0001 0.0001 Canine PA-OP 0.0001 0.0001 0.0001 CV 0.0001 0.0001 CT-CS1 0.9999 PE 0.0001 0.0001 0.0001 0.0001 0.0001 PA-FP 0.801 0.0001 0.0001 0.0001 Molar PA-OP 0.0001 0.0001 0.0001 CV 0.0001 0.0001 CT-CS1 0.9999 In canine region, there were no significant differences between periapical radiography and CT, or between CT-CS1 and CT-CS2. In molar region, periapical radiography indicated significant differences for other imaging modalities. associated with dental implants is used for diagnosis of the recipient site. Ideally, this will allow assessment in terms of quality and amount of bone, location of anatomical structures, and longitudinal morphological change through bone loss along the implant surface. Digital subtraction radiography was introduced into the field of periodontal research in the 1980s as one of the most versatile approaches to assessment of longitudinal bone change 8,10,11,28). Jeffcoat et al. 12) used a reference wedge calibrated to different thicknesses, which was incorporated into the periapical radiograph. The image of the wedge obtained was used to determine thickness of wedge, which corresponded to the same gray level change as the bone loss area. Historically, there is another approach to the assessment of longitudinal bone change: that is, different criteria have been utilized to assess the success of implants based on radiographic appearance or measurement of distance. Schnitman and Shulman 22) recommended that bone loss was not greater than 1/3 of the implant length. Albrektsson et al. 1) and Smith and Zarb 23) established a success criterion of 0.2 mm of bone loss annually after the first year of implantation. Furthermore, the American Dental Association 2) established a radiographic criterion of 2 mm of vertical bone loss at 5

Implant Length Measurement on Radiographs 111 Fig. 4 Variance of measuring distance of implant fixture by each observer in canine region a: PE, b: PA-FP, c: PA-OP, d: CV, e: CT-CS1, f: CT-CS2 years. To use these criteria for the radiographic analysis of longitudinal implant bone loss in clinical trials, first it is necessary to obtain precise measurement of implant length itself prior to implantation if it is to be used effectively as an index of bone loss. However, these earlier studies did not specify the radiographic method to be used for actual measurement of bone loss, and they did not research the measurement precision of implant length in each radiographic modality. Therefore, this study focused on this point. PE radiographs are utilized in pre-surgical planning of implant treatment, intra-operatively, and for longitudinal assessment, especially for assessment of limited areas or individual implant sites. Adjacent anatomical structures may not be visible on the radiograph due to the limitation of the areas, while PE radiographs have minimal distortion when they are well-angulated applying the standardized projection geometry previously described by Duckworth et al. 6) Additionally, exposure dose of PE radiography is extremely low compared with that of other modalities. Therefore, PE radiographs are particularly well-suited for

112 Wakoh M et al. Fig. 5 Variance of measuring distance of implant fixture by each observer in molar region a: PE, b: PA-FP, c: PA-OP, d: CV, e: CT-CS1, f: CT-CS2 longitudinal assessment of implant bone loss rather than for the planning of surgical procedure. The results of this study demonstrated that the measured distance on the PE radiograph was the closest to the actual length of the implant fixture without regard to implantation site, and measurement accuracy radiograph was almost the same as, or better than, that of CT-CS image. Inter-observer variance in the PE radiographs was smaller in both regions compared with that of other modalities. Although CT tomograms are commonly recommended for measurements 26), the inter-observer variance in the PE radiographs was smaller than that of the CT tomograms, especially, in the canine region. This suggests that the measurement value on PE radiographs is the most reliable, regardless of observers. This is probably due to the sharpness and resolution of images obtained with standardized PE radiography. Furthermore, the standardized PE radiograph probably provides the highest reliability and reproducibility in terms of linear measuring distance between the alveolar ridge and other anatomical structures in pre-surgical assess-

Implant Length Measurement on Radiographs 113 Table 2 Variance of measurement data between intra- and inter-observer for each imaging modality Cases Modalities Mean square (Intra-observer) Mean square (Inter-observer) F-value p-value Canine Molar PE 0.059 0.037 0.63 0.7426 PA-FP 0.045 0.271 5.999 0.0008 PA-OP 0.012 0.286 24.509 0.0001 CV 0.037 0.131 3.54 0.0123 CT-CS1 0.035 0.194 5.523 0.0013 CT-CS2 0.014 0.187 13.202 0.0001 PE 0.047 0.252 5.39 0.0015 PA-FP 0.031 0.51 16.608 0.0001 PA-OP 0.03 0.545 18.463 0.0001 CV 0.01 0.251 24.325 0.0001 CT-CS1 0.053 0.289 5.395 0.0015 CT-CS2 0.024 0.294 12.399 0.0001 Variance of measurement data is indicated as mean square. Variance in inter-observer for periapical radiographs was smaller than that for other radiographic images. ment, where anatomical structure is described on radiographs. PA radiographs provide a global evaluation for multiple implant emplacement. The large area imaged with this technique is useful in the initial planning of treatment or screening, including for assessment of bone loss. However, this method has a number of limitations compared with PE radiography: lack of clarity due tomography, inconsistent magnification at each region, decreased resolution and lack of standardization of projection geometry. In this analysis also, PA radiographs showed the greatest measurement deviation to the actual length of implant fixture, and showed an extremely significant difference compared with PE radiographs. These disadvantages mean there is a risk of loss of measuring precision. It has been suggested that cross-sectional views obtained using CV tomography are an effective technique for evaluation of bone width and bone height from one image of a prospective implant site 15). In terms of measurement of distance, complicated manipulation is required to estimate the actual distance of the structure; and the measured distance on the film has to be converted using a conversion chart. This technique also has limitations: availability of the machines themselves; the skill required to obtain reproducible images, which have to be tomographic images in the same plane as the axis of the implant fixture; image blurring caused by tomographic principle; and the popularization of CT tomography. In this study, measurement accuracy of implant length in CV tomograms using a conversion chart was higher than that for PA radiographs, but was obviously inferior to that for PE radiographs. Nowadays, CV tomograms also should not be utilized in longitudinal and precise measurement at local implantation sites, as well as PA radiographs. Many authors believed that CT images were the most accurate technique for implantation site diagnosis for pre-surgical assessment 9,16,19,20). The American Academy of Oral and Maxillofacial Radiology (AAOMR) 26) also recommended CT tomography for implant site assessment, including precise measurement of distances in three dimensions. Our study also demonstrated that CT-CS images offered high accuracy in measuring distance of implant length. However, the measured value was similar or inferior to those obtained in PE radiographs, which was unexpected.

114 Wakoh M et al. Medical CT is also not suitable for longitudinal bone loss assessment depending on implant length at local implantation sites because of the low spatial resolution and high exposure dose. In conclusion, standardized PE radiographs should be utilized for longitudinal measurement depending on implant length at local sites, due to the highest linear measurement precision with dose limitation available. References 1) Albrektsson T, Zarb G, Worthington P, Eriksson B (1986) Long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1: 11 25. 2) American Dental Association (1996) Dental endosseous implants; an update. ADA Council on Scientific Affairs. J Am Dent Assoc 127: 1238 1239. 3) Arcuri MR, Lang BR (1994) Diagnostics and treatment planning, Osseointegration in Dentistry, Worthington P, Lang BR, LaVelle WE eds., pp. 69 83, Quintessence, Chicago. 4) Beason RC, Brooks SL (2001) Preoperative implant site assessment in southeast Michigan. J Dent Res 80:137 (Abstr. 810). 5) Cavalcanti MG, Yang J, Ruprecht A, Vannier MW (1999) Accurate linear measurements in the anterior maxilla using orthoradially reformatted spiral computed tomography. Dentomaxillofac Radiol 28:137 140. 6) Duckworth JE, Judy PF, Goodson JM, Socransky SS (1983) A method for geometric and densitometric standardization of intraoral radiographs. J Periodontol 54:435 440. 7) Fritz ME (1996) Implant therapy II. Ann Periodontol 1:796 815. 8) Grondahl H-G, Grondahl K, Webber RL (1983) A digital subtraction technique for dental radiography. Oral Surg 1:96 102. 9) Hanazawa T, Sano T, Seki K, Okano T (2004) Radiologic measurements of the mandible: a comparison between CT-reformatted and conventional tomographic images. Clin Oral Impl Res 15:226 232. 10) Hausmann E, Christersson L, Dunford R, Wikesjo U, Phylo J, Genco RJ (1985) Usefulness of subtraction radiography in the evaluation of periodontal therapy. J Periodontol 56 (Suppl):4 7. 11) Jeffcoat MK, Reddy MS, Webber RL, Williams RC, Ruttimann UE (1987) Extraoral control of geometry for digital subtraction radiography. J Periodont Res 22:396 402. 12) Jeffcoat MK, Reddy MS, van den Berg HR, Bertens E (1992) Quantitative digital subtraction radiography for the assessment of periimplant bone change. Clin Oral Impl Res 3: 22 27. 13) Lekholm U, Zarb GA (1985) Patient selection and preparation, Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry, Branemark P-I, Zarb GA, Albreksson T eds., pp. 199 209, Quintessence, Chicago. 14) Lindh C, Peterson A (1989) Radiologic examination for location of the mandibular canal: a comparison between panoramic radiography and conventional tomography. Int J Oral Maxillofac Implants 4:249 253. 15) Miles DA, van Dis ML (1993) Implant radiology. Dent Clin North Am 37:645 668. 16) Miller C, Nummikoski PV, Barnett D (1990) Cross-sectional tomography. Oral Surg Oral Med Oral Pathol 70:791 797. 17) Naitoh M, Katsumata A, Nohara E, Ohsaki C, Ariji E (2004) Measurement accuracy of reconstructed 2-D images obtained by multislice helical computed tomography. Clin Oral Impl Res 15:570 574. 18) Peltola JS, Mattilla M (2004) Cross-sectional tomograms obtained with four panoramic radiographic units in the assessment of implant site measurements. Dentomaxillofac Radiol 33:295 300. 19) Petrikowski C, Pharoah M, Schmitt A (1989) Presurgical radiographic assessment for implants. J Prosthet Dent 61:59 64. 20) Reddy MS, Mayfield-Donahoo T, Vanderven FJJ, Jeffcoat MK (1994) A comparison of the diagnostic advantages of panoramic radiography and computed tomography scanning for placement of root form dental implants. Clin Oral Impl Res 5:229 238. 21) Sakakura CE, Morais JAND, Loffredo LCM, Scaf G (2003) A survey of radiographic prescription in dental implant assessment. Dentomaxillofac Radiol 32:397 400. 22) Schnitman PA, Shulman LB (1979) Recommendations of the consensus development conference on dental implant. J Am Dent Assoc 98:373 377. 23) Smith DE, Zarb GA (1989) Criteria for success of osseointegrated dental implants. J Prosthet Dent 62:67 72. 24) ten Bruggenkate CM, van der Linden LW, Oosterbeek HS (1989) Parallelism of implants visualized on the orthopantomogram. Int J Oral Maxillofac Surg 18:213 215. 25) Todd AD, Gher ME, Quintero G, Richardson

Implant Length Measurement on Radiographs 115 AC (1993) Interpretation of linear and computed tomograms in the assessment of implant recipient sites. J Periodontol 12:1243 1249. 26) Tyndall DA, Brooks SL (2000) Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 89:630 637. 27) Wakoh M, Nishikawa K, Otonari T, Yamamoto M, Harada T, Sano T, Yajima Y, Ooguro T (2006) Digital subtraction technique for evaluation of peri-implant bone change in digital dental imaging. Bull Tokyo Dent Coll 47:57 64. 28) Webber RL, Ruttimann UE, Grondahl H-G (1982) X-ray image subtraction as a basis for assessment of periodontal changes. J Periodont Res 17:509 511. Reprint requests to: Dr. Mamoru Wakoh, Department of Oral and Maxillofacial Radiology, Tokyo Dental College, 1-2-2 Masago, Mihama-ku, Chiba 261-8502, Japan