CORESTA RECOMMENDED METHOD N 25

Similar documents
CORESTA RECOMMENDED METHOD N 22

INTERNATIONAL STANDARD

CORESTA RECOMMENDED METHOD N 8

CORESTA RECOMMENDED METHOD NÄ 9

INTERNATIONAL STANDARD

This document is a preview generated by EVS

CORESTA Recommended Method No. 78

CORESTA Recommended Method No. 84

Routine Analytical Chemistry Sub-Group Report Berlin 2016

Guideline for Measurement Method of Harmful Ingredients in Cigarette-type Smoking Craving Suppressant

Cigarettes Determination of tobacco specific nitrosamines in mainstream cigarette smoke Method using LC-MS/MS

TNCO Testing procedures

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

CORESTA Recommended Methods with history and correspondence with ISO Standards

Cigarette Smoke Generator

Smoking Puff Ratio of Cigarette and Its Determination Method

CORESTA Recommended Method No. 76

Disclosure to Promote the Right To Information

Advanced in vitro exposure systems

CORESTA Guide N o 18

Routine Analytical Chemistry Sub-Group. Technical Report

PROCEDURE FOR GENERATION AND TESTING OF MAINSTREAM TOBACCO HEATING SYSTEM (THS or IQOS) AEROSOL USING A LINEAR SMOKING MACHINE

FEATURES AND PERFORMANCE OF THE HPP SMOKING MACHINE. Dritan Xhillari

Ian M. Fearon, Madeleine Ashley, Christopher J. Shepperd, Graham Errington. Sheri A. Bowman, John W. Caraway, Peter Chen, Paul R.

The Effect of Puff Duration on Smoke Chemistry

2015 Report 05 October 2015 Jeju, South Korea

cigarettedesigner 4.0

The Effect of Puff Profile and Volume on the Yields of E-Cigarettes

This document is a preview generated by EVS

Development and Validation of a Portable Puffing Topography Analyser

Center for Tobacco Reference Products Update on 1R6F Production and Proficiency Testing Program

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report

E-Cigarette Aerosol Analysis Report

Dentistry Test methods for machining accuracy of computeraided milling machines

CORESTA Recommended Method No. 85

E-Cigarette Aerosol Analysis Report

This document is a preview generated by EVS

E-Cigarette Aerosol Analysis Report

METHOD DEVELOPMENT AND VALIDATION: QUANTIFICATION OF METALS IN LIQUIDS AND AEROSOL OF E-CIGARETTES

Sterilization of health care products Radiation. Part 3: Guidance on dosimetric aspects of development, validation and routine control

CORESTA RECOMMENDED METHOD N 39

CORESTA Recommended Method No. 56

CORESTA Recommended Method No. 74

Pierre-Marie GUITTON Next Generation Nicotine Delivery London June, 2017

Water pipe tobacco smoking from the first idea to an International Standard

E-Cigarette Aerosol Analysis Report

Technical Report. Chemical and physical performance of a filter for cigarette smoke. (patents n. BO2014A )

Development and validation of a device for measuring puffing topography of e-cigarette users

ISO INTERNATIONAL STANDARD. Dentistry Reversible-irreversible hydrocolloid impression material systems

Particle Size Distribution of E-Cigarette Aerosols and the Relationship to Cambridge Filter Pad Collection Efficiency

Measure #404: Anesthesiology Smoking Abstinence National Quality Strategy Domain: Effective Clinical Care

E-Vapour (EVAP) Sub-Group 2017 Report. Kitzbühel, Austria October 10, 2017

Non-destructive testing Penetrant testing. Part 2: Testing of penetrant materials

HEALTH REGULATION # 13 TOBACCO HANDLERS PERMITS

E-cigarette consumption and puffing topography data. Dr Sudhanshu Patwardhan FDA CTP Workshop, Hyattsville, Maryland. March 9, 2015.

Quality ID #404: Anesthesiology Smoking Abstinence National Quality Strategy Domain: Effective Clinical Care

Effect of magnesium hydroxide as cigarette paper filler to reduce cigarette smoke toxicity

DEVELOPMENT OF A TECHNIQUE FOR THE DETERMINATION OF ph-values OF AEROSOLS GENERATED BY E-CIGARETTES

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

This document is a preview generated by EVS

Contribution To Standards Development For Next Generation Products. Eduardo BEREA Alternative Ingredients ENDS 2018 London 4-5 June 2018

S.C. Moldoveanu, A.G. Hudson, A. Harrison. R.J. Reynolds Tobacco Co.

Dentistry Dental amalgam

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

ISO/TS TECHNICAL SPECIFICATION. Dental materials Testing of adhesion to tooth structure

Analytical method validation. Presented by Debbie Parker 4 July, 2016

Anaesthetic and respiratory equipment Nebulizing systems and components

Cigarette Smoking Machine CSM-SCSM. User s Manual

Applicant Name: GD Sigelei Electroinc Tech Co., Ltd B7 Building, No.1 District, Xicheng Science and Technology Park, Hengli Town, Dongguan, China

ISO IDF 176 INTERNATIONAL STANDARD. Milk and milk products Microbial coagulants Determination of total milkclotting

Anaesthetic and respiratory equipment Peak expiratory flow meters for the assessment of pulmonary function in spontaneously breathing humans

ISO INTERNATIONAL STANDARD

Contribution To Standards Development For Next Generation Products. Dr Nils ROSE

October 2, 2018 Japan Tobacco Inc. The Effects of T-Vapor products on Indoor Air Quality

V2 NOTEBOOK-CIG AND/OR V2 POWER-CIG

Thermal Degradation Studies of Electronic Cigarette Liquids Part 2: Development of a Model Reaction System Used to Study α-dicarbonyl Formation

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Sterile hypodermic needles for single use Requirements and test methods

Dentistry Endodontic instruments. Part 3:

Organisation Internationale de Métrologie Légale

Fundamentals of Pressure Transducers

Sterilization of health care products Radiation. Part 2: Establishing the sterilization dose

ISO INTERNATIONAL STANDARD. Ergonomics Accessible design Sound pressure levels of auditory signals for consumer products

Test-Report No.:

Smoking and Nicotine Replacement Therapy (NRT) Lec:5

This document is a preview generated by EVS

Technical Report. Chemical and physical performance of a filter for cigarette smoke PCT IB2018/

General concepts in the Ph. Eur.: theory and rationale

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Acoustics Estimation of noiseinduced

CHARACTERIZING PASSIVE EXPOSURE TO TOBACCO SMOKE

This document is a preview generated by EVS

FIt s a late summer s afternoon in Jarrow, A LAB OF ITS TIME

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

Article 5. 1) Act No. 18/2003, Article 10.

Air Quality assessment during indoor use of the Tobacco Heating System 2.2

Transcription:

CORESTA RECOMMENDED METHOD N 25 AMBIENT AIR FLOW AROUND CIGARETTES IN ROUTINE ANALYTICAL SMOKING MACHINES : CONTROL AND MONITORING (August 1991) 0. INTRODUCTION The development of smoking machines has taken place over perhaps 45 years. However because the mechanical configurations which can meet this Recommended Method differ greatly, it has been found from the work of a special Task Force (*), established by CORESTA, that additional specification of the immediate smoking machine environment is necessary. This leads to better reproducibility in the international inter-laboratory comparisons which are often required. It is doubtful if a general mechanical specification can be written to cover all types of smoking machines and so, as well as a general specification, it is necessary to provide examples for the designs most generally used. There are two principal designs which satisfy CORESTA Recommended Method RM N 22: - type (a) in which the position of the cigarette in its holder is fixed, i.e. adjustments are made by moving the puff termination device ; - type (b) in which the position of the puff termination device is fixed, i.e. adjustments are made by moving the cigarette and its holder. 1. FIELD OF APPLICATION This Recommended Method - specifies the ambient air velocities surrounding cigarettes in an analytical smoking machine during the smoking process and mechanical design of the enclosures immediately surrounding them; - specifies the methods of air velocity measurement and the location where air velocity shall be measured. 2. REFERENCES CORESTA - Recommended Method N 7: 1991 Determination of nicotine in the main stream smoke of cigarette by gas chromatographic analysis. (*) The Task Force, composed of members of the CORESTA Smoke and Technology Groups, has conducted collaborative studies in 1988, 1989 and 1990. The studies have already resulted in the production of Recommended Methods N 21, 22, 23 and 24. - 1 -

CORESTA - Recommended Method N 8: 1991 Determination of water in the mainstream smoke of cigarettes by gas chromatographic analysis. CORESTA - Recommended Method N 22: 1991 Routine analytical cigarette-smoking machine, specifications, definitions and standard conditions. CORESTA - Recommended Method N 23: 1991 Determination of total and nicotine-free dry particulate matter using a routine analytical cigarette-smoking machine - determination of total particulate matter and preparation for water and nicotine measurements. ISO 10315: 1991 Cigarettes - Determination of nicotine in smoke condensates - Gas chromatographic method. ISO 10362-1: 1991 Cigarettes - Determination of water in smoke condensates - Part 1: Gas chromatographic method. ISO 3308: 1991 Cigarettes - Routine analytical cigarette-smoking machine - Definitions and standard conditions. ISO 4387: 1991 Cigarettes - Determination of total and nicotine-free dry particulate matter using a routine analytical smoking machine. 3. DESIGN OF SMOKING MACHINE ENCLOSURE Examples of mechanical specifications for the design of suitable enclosures for machines which satisfy CORESTA Recommended Method N 22 are given. 3.1. Smoking machine type (a) Figures 1 and 2 show schematic designs of the enclosure including the features which shall be incorporated. 3.2. Smoking machine type (b) This type of machine exists with 20 and 8 channels. Features common to both are shown in detail in figure 3. Figure 4 shows a schematic design of the enclosure including the features which shall be incorporated in 20 channel versions. Figure 5 is appropriate to 8 channel versions. - 2 -

4. AIR VELOCITY MEASUREMENT LOCATIONS The reference points at which measurement of air velocity shall be made are given. Cigarette holders but not cigarettes shall be in place during measurements. The required measurements shall be made such that the centre of the air velocity meter probe is within ± 2 mm in each plane of the specified position. 4.1. Smoking machine type (a) The air velocity shall be measured at a point on the axis of the cigarette as held in its holder 74 mm towards the end of the cigarette which is to be lit from a datum defined by the position of the butt (mouth) end of the cigarette. 4.2. Smoking machine type (b) 4.2.1. The air velocity shall be measured at a point on the axis of the cigarette as held in its holder 40 mm towards the end of the cigarette which is to be lit measured from the position of the puff termination device. 4.2.2. In order to check the uniformity of air flow across the smoking machine, measurements shall be made at least daily at a central port and at a port near each extreme. Additional measurements may be required on installation or relocation of the machine. 5. SPECIFICATION OF THE AIR VELOCITY METER An air velocity meter capable of an accuracy of at least ± 20 mm s -1 at 200 mm s -1 shall be used. The air velocity measuring equipment shall be capable of integrating air velocity data over a minimum period of 10 s. The value of a measurement of air velocity shall consist of the average of not less 10 replications of 10 s integrations. Notes : 1. An omnidirectional probe is prefered. 2. Suitable meters are made by Lambrecht Gmbh and TSI Inc. This information is given for the convenience of users of this Recommended Method and does not constitute an endorsement by CORESTA of the product named. Equivalent products may be used if they can be shown to lead to the same results. 6. STANDARD VALUE OF AIR VELOCITY The standard value of the air velocity shall be 200 mm s -1. - 3 -

7. SETTING AND CHECKING AIR VELOCITY Air velocity shall be set at the standard value at least daily. It is normal practice to measure and if required to adjust the air flow in extraction ducts so that the standard air velocity at the reference point is achieved. Notes : 1. Laboratory procedures should aim to ensure that the air velocity average during a smoking run lies in the range 200 mm s -1 ± 30 mm s -1. 2. For smoking machines type (b), the air velocity measured at an individual port should be within the range 200 mm s -1 ± 50 mm s -1. 3. Extreme external atmospheric conditions, e.g. high wind velocity, wide relative humidity variations, may affect air flow conditions in smoking machine enclosures. In such circumstances more frequent checks of air velocity should be made. 8. SUBSIDIARY METHOD OF TEST When it is not possible to obtain and use the equipment to satisfy 6 and 7, confirmation of the achievement of the Standard Smoking conditions can be obtained by test smoking cigarettes the yield of which has been previously determined. If this subsidiary method of test has been used, a note to this effect shall be made in the test report clause 8 CORESTA Recommended Method N 23, clause 10 Recommended Method N 7 and clause 11 Recommended Method N 8. 8.1. Use of reference cigarette 8.1.1. A large batch of reference cigarettes should be made and extensively tested according to the method given in CORESTA Recommended Method N 23. Mean data for nicotine free dry particulate matter and nicotine with confidence levels about the mean should be derived. 8.1.2. A sample of these cigarettes should be smoked according to CORESTA Recommended Method N 23 and the data compared with the reference values 8.1.1. Air velocity may be judged to be correct if the values obtained from the trial smoking when compared to the reference value for nicotine-free dry particulate matter and/or nicotine are consistent with the repeatability and reproducibility given in 9 of CORESTA Recommended Method N 23 and/or 9 of Recommended Method N 7 respectively. In the event of discrepancies greater than these, the air flow controls should be adjusted until the values are consistent. Note : Care must be taken when using this subsidiary method of test to ensure that all other controls of the smoking machine and smoking process are correctly established before adjusting the flow controls. - 4 -

FIGURE 1 MACHINE WITH FIXED CIGARETTE POSITION - 5 -

FIGURE 2 EXAMPLE OF AN ENCLOSURE FOR A ROTARY SMOKING MACHINE WITH HOOD - 6 -

FIGURE 3 MACHINE WITH FIXED PUFF TERMINATION POSITION - 7 -

FIGURE 4 SCHEMATIC VIEWS OF 20 CHANNEL LINEAR MACHINE - 8 -

FIGURE 5 SCHEMATIC VIEWS OF 8 CHANNEL LINEAR MACHINE GENERAL VIEW WITHOUT CARBON MONOXIDE COLLECTION - 9 -