AVANTEON. Operative Technique & Catalogue Information AVANTEON

Similar documents
TaperFit. Cemented Total Hip Replacement Surgical technique

Cementless Tapered Femoral Stem Surgical technique

Cementless Tapered Femoral Stem Surgical technique

Manza Cup HA SURGICAL TECHNIQUE.

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

MetaFix. Cementless Total Hip Replacement Surgical technique

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Bone Preservation Stem

FLH /11

Preoperative Planning. The primary objectives of preoperative planning are to:

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

Trinity. Advanced Bearing Acetabular System Surgical technique

Approach Patients with Confidence

Clinical Evaluation Surgical Technique

DIRECT ANTERIOR APPROACH. Guide for use with the Furlong Evolution Femoral Stem & CSF Plus Acetabular Cup

Bi-Polar 22.2mm & 28mm System - Operative technique

Aesculap Trilliance Triple Tapered Polished Hip Stem

Exeter Contemporary Flanged Cup. Exeter. Providing Solutions

AML Hip System. Design Rationale/ Surgical Technique

Progeny Hip Stem. Surgical Protocol and Product Specifications

HELIOS h i p s y s t e m

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Approach Patients with Confidence

ACETABULAR CUP SURGICAL TECHNIQUE

Ovation Hip System. Surgical Technique

operative technique Kent Hip

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Optimum implant geometry

Exeter V40 Femoral Stem

Exeter X3 RimFit Acetabular Cup

Surgical Technique. Hip System

Efficacy Innovation ABG II. Brochure. Surgical Protocol. Cemented Stem

HIP SYSTEM SURGICAL TECHNIQUE

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Absolut TM Cemented Stem. Surgical Technique

21st Century Fracture Management ETS. Surgical Protocol

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Rx90 Total Hip System Acetabular Series

Scan Bi-Polar 22/28. Operative Technique

Surgical Technique. Cup System

EC Certification. FULL QUALITY ASSURANCE SYSTEM Directive 93/42/EEC for Medical Devices, Annex II excluding (4)

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

PRODUCT SCHEDULE FOR CERTIFICATE CE JRI ORTHOPAEDICS LIMITED

Versys Advocate V-Lign and Non V-Lign Cemented Hip Prosthesis

Taperloc Complete Hip System. Surgical Technique

Revision. Hip Stem. Surgical Protocol

Integral 180 Surgical Technique

U2 PSA. Revision Knee. Surgical Protocol

ADEPT Extra Fixation Cup. Operative Technique. Delivering Results Through Performance

Surgical procedure. METS Modular Proximal Femur

S U R G I C A L T E C H N I Q U E

9800 Metric Blvd. Austin, Texas

pact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

CemtA Stem. Surgery Manual. cemented femoral Stem. veterinary implants

OPTIONAL/ADDITIONAL INSTRUMENTS

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Triple Tapered Stabilised Hip C-STEM AMT. Surgical Technique

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Dual Mobility System Surgical technique

SURGICAL TECHNIQUE. Entrada Hip Stem

PLR. Proximal Loading Revision Hip System

*smith&nephew CONTOUR

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Distal Cut First Femoral Preparation

Dual Mobility System Evaluation surgical technique

Medial Rotation Knee. Forever Active. Landmark Operative Technique Supplement: No.1 All-Polyethylene Tibia (Cemented)

FMP Surgical Technique

UNDERSTANDING TRADITION, MASTERING INNOVATION. Surgical Technique

Surgical Technique r5.indd 1 12/8/10 10:36 AM

asterloc Surgical Technique HIP SYSTEM UNDERSTANDING TRADITION, MASTERING INNOVATION Hip Knee Spine Navigation

Trilogy Acetabular System

Surgical Technique CHARNLEY CHARNLEY, THE WORLD S MOST SUCCESSFUL HIP IMPLANT

CPT 6 Stainless Steel Primary Hip System

Trilogy Acetabular System

Cemented femoral stem - type CSC

Tradition Hip Primary Surgical Technique

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

MetaFix. Cementless Total Hip Replacement Surgical technique

RECOVERY. P r o t r u s i o

CHARNLEY MODULAR HIP SYSTEM SURGICAL TECHNIQUE. This publication is not intended for distribution in the USA.

ARTICUL/EZE Mini Taper. C-STEM AMT Hip. Design Rationale & Surgical Technique

Ceramic Femoral Heads and Acetabular Cup Liners

Mako Total Hip Direct anterior approach

Hip Resurfacing System

Natural-Hip System. Surgical Technique. Addressing surgical concerns comprehensively

CPCS Collarless Polished Cemented Stem

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

TOTAL HIP REPLACEMENT:

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

TaperFill. Surgical Technique

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

Surgical technique MkII instrumentation

Transcription:

AVANTEON Operative Technique & Catalogue Information AVANTEON H I P S Y S T E M

Pre-operative Planning The overall aim of pre-operative planning is to establish anatomical data from the patient to guide the surgeon towards the optimal size of the femoral stem and acetabular component and their ideal position after implantation. Anteroposterior and lateral X-rays with the hip in neutral position are overlaid with the template film for full pre-operative evaluation. PICTURE ARCHIVING AND COMMUNICATION SYSTEMS (PACS) templates are also available via your PACS software provider. The X-ray templates for the AVANTEON Hip system are set at 115% magnification. During pre-operative planning, the surgeon will normally establish the appropriate osteotomy level and estimate the femoral and acetabular implant size, allowing for adequate and continuous cement mantles. 1

Femoral Head Resection Resection cutouts Head centres Stem sizes Central axis of the stem The centre of rotation of the femoral head can also be established, which will help determine appropriate offset and neck length to achieve correct soft tissue tension and leg length.the appropriate level to make the femoral neck osteotomy can be identified using the osteotomy guide, and this should be used in conjunction with reference to the pre-operative templating. The AVANTEON osteotomy guide is placed over the exposed proximal femur and positioned so that the alignment guideline on the device aligns with the longitudinal femoral axis. The guide can then be moved along the longitudinal axis superiorly or inferiorly so that the centre of the femoral head matches the appropriate stem offset as determined by preoperative templating. AVANTEON H I P S Y S T E M 42

Acetabular Cup Implantation Acetabular Preparation The acetabular rim is fully exposed, identifying and removing all peripheral and medial osteophytes. Starting with the smallest reamer, the articular cartilage is progressiveley reamed until bleeding subchondral bone becomes visible. It is important not to over-ream the anterior and posterior walls. In order to achieve a 3mm thick cement mantle, the final implant is downsized by 6mm from the final reamer size used. Several holes are then made around the acetabulum using the acetabular step drill. These holes are created to aid keying and fixation of the bone cement. Care should be taken to place the holes where the bone is at its thickest and to avoid perforation medially and anteriorly where it is at its thinnest. 3

Acetabular Cup Insertion The rings on the flange are set 2mm apart. Present the cup to the prepared acetabulum to assess the amount of flange to remove, and trim the flange so that the periphery of the flange sits just inside the acetabular rim. The bone cement is mixed as per the manufacturer s instructions and guidelines. Pulsed lavage and drying of the bone bed are recommended prior to cementation. Bone cement is introduced into the acetabulum in the normal manner. An acetabular pressuriser should be used to intrude the bone cement into the prepared acetabular bony bed, ensuring good cement-bone interdigitation. (Bone cement and pressuriser are not supplied in the standard AVANTEON hip system). The acetabular cup is attached to the cup inserter by pressing the pins on the inserter into the holes on the inner rim of the cup. The acetabular cup is introduced once the bone cement has reached the stage when its viscosity is suitable. 64

Acetabular Cup Insertion 45 The acetabular cup is introducted so the shaft of the inserter is at 90 to the sagittal plane of the body. The cup will then be located with 45 of abduction. The acetabular cup pusher engages with the acetabular cup inserter, and pressure is applied to the cup directly in line with the cup face or 45 to the vertical of the acetabular inserter handle. The anteversion handle can be used to confirm the degree of anteversion relative to the coronal plane of the body. The degree of anteversion is at the discretion of the surgeon. Note: The pressure applied to the acetabular pusher should be in line with the anteversion handle. 5

Pressure is maintained on the acetabular cup with the AVANTEON cup pusher, which attaches onto the AVANTEON cup inserter. After satisfactory placement of the cup in the acetabulum and confirmation of correct alignment, the inserter is ejected from the cup by depressing the button on the end of the inserter. Once the inserter has been ejected, the acetabular cup pusher must be immediately reintroduced directly into the cup to maintain pressure on the cement. Any extruded bone cement is removed from the periphery of the cup, and pressure is removed until the bone cement is adequately polymerised. After polymerisation is complete, the acetabular cup pusher is removed. Any cement debris and further cement extrusions must be removed from around the cup. AVANTEON H I P S Y S T E M 86

Femoral Canal Preparation Note: Pre-operative planning and templating, by either PACS or hard-copy x-rays is essential when using a tapered, polished femoral stem to ensure correct leg length, soft tissue tension, and restoration of anatomy. Variations in patient anatomy mean that using the same anatomical reference points in the same way in every patient is inappropriate. Attach the box osteotome to the broach handle and open up the medullary canal by aligning the cut of the osteotome with the piriformis. The appropriate degree of anteversion should be determined at this point. In preparation for broaching and distal cement insertion, the femoral canal is enlarged using one or both of the straight reamers. The reamers are used sequentially, smallest first, to widen the femoral canal until the required diameter and depth are achieved while maintaining neutral axial alignment within the femur. It is recommended that there is a 1-2cm depth of cement between the distal tip of the stem centraliser and the top of the cement plug. Therefore, as a guide, the reamer should be introduced to a depth of 20cm measured to the tip of the greater trochanter. 7

Femoral Rasping The AVANTEON broaching system is designed to provide a uniform continuous cement mantle of at least 2mm. The medial cement mantle increases from 2mm at the distal tip of the stem to 4mm in the calcar region. 150mm 50 45 38 Preoperative planning will enable the surgeon to identify the correct offset stem to use. The medial curve of the broach and the stem vary depending on the stem offset. It is essential to use the correct broach that corresponds to the stem offset determined in the preoperative planning. The smallest broach (CDH) is used first to prepare the proximal femur. Further broaches increasing in size sequentially are used until the broach corresponding to the templated stem size is reached. Maintaining neutral axial alignment within the medullary canal is essential. The anteversion rod may be attached to the broach handle to aid alignment and for additional guidance while broaching. 8

Trial Reduction Note: The CDH and 38mm offset stems use the same trial neck The two small holes and the flat on the rasp where the trial neck sits correspond to the three depth markings on the definitive stem. The rasp can be inserted to the desired depth as indicated preoperatively, taking note of the depth marking when rasping. The correct offset trial neck is attached to the spigot on the rasp. The trial neck must be seated properly on the rasp to ensure that the appropriate trial neck has been selected. The trial head with the neck length required to re-establish the femoral head centre as measured in pre-operative x-ray templating is selected. The hip is reduced, and joint stability, leg length, and range of motion are checked. Further adjustments can be made using different neck length trial heads. 9

Cement Plug Insertion Stem 10mm to 20mm cement gap Typical distal cement plug The JRI intramedullary cement plug system can be used in conjunction with the AVANTEON cemented hip system. The intramedullary cement plugs are available in a comprehensive range of sizes from 10mm to 20mm maximum diameter in 1mm increments. Made from UHMWPE, when sized and fitted correctly the plugs provide a secure barrier against the ingress of bone cement distally down the femoral canal, enabling pressurisation. The size of cement plug to be used should be determined by using the intramedullary trials to estimate the diameter of the femoral medullary canal at a depth 10-20mm beyond where the tip of the distal centraliser is intended to be. This is approximately 190mm - 200mm from the greater trochanter. As a guide, if only the small intramedullary reamer was used to start with, trial for the size 10mm cement plug initially. Trial for the 14mm cement plug if the large intramedullary reamer was used. Increase the size of the trial until resistance is felt at a depth of approximately 18cm from the greater trochanter. It is recommended that a cement plug 1mm greater than the trial is used to ensure a secure fit. AVANTEON H I P S Y S T E M 10

Stem Implantation In preparation for cementing, the medullary canal is cleared of debris and cleaned using pulsed lavage and then dried. The cement is then inserted using a cement gun and a retrograde filling technique until the canal is almost filled. A pressurisation seal is then added, before completion of filling of the canal, to enable optimum cement pressurisation. The optimum time for insertion of the femoral stem will depend upon the cement manufacturer s guidelines. (Bone cement, cement gun, and the femoral cement pressuriser are not supplied with the AVANTEON cemented hip system). A separately packed stem centraliser is attached to the distal tip of the stem. The distal tip of the introducer is inserted into the aperture on the lateral shoulder of the stem. 11

The pressurisation seal is removed, ensuring that the proximal cement is clean and dry. The femoral stem is inserted to the predetermined depth, referencing the depth indication markings on the stem while ensuring a neutral axial alignment of the stem is maintained. The depth to which the stem is inserted and the degree of anteversion are at the discretion of the surgeon. The stem is held in place with the stem introducer until the bone cement has polymerised. (Refer to the bone cement manufacturer s guidelines). The stem introducer is gently removed while applying counter pressure on the stem. It is recommended that a further trial reduction is performed with the trial femoral head at this stage. The neck of the stem should then be cleaned and dried before the definitive femoral head of choice is placed onto the taper and impacted. 12

The definitive femoral head with the desired neck length is placed carefully onto the clean taper of the femoral stem using a twisting motion. The definitive femoral head is impacted using the head impactor, with a single firm blow, ensuring the surface of the head is not scratched or damaged in any way. After ensuring that the cup and femoral head are clean and free from debris, the hip is reduced and closed. 13

AVANTEON and Furlong Compatibility Chart AVANTEON H I P S Y S T E M BIOLOX delta Cups AVANTEON Cup If using with CoCr Femoral Head, use ONLY AVANTEON CoCr Femoral Head. CSF, CSF Plus and Cemented Mueller type cup Hemiarthroplasty Heads Heads AVANTEON CoCr BIOLOX delta Furlong CoCr Bi-Polar Mono-Polar Stem AVANTEON H I P S Y S T E M AVANTEON H I P S Y S T E M 14

Implant Range Information CAT. NO STEM * 0510000 CDH 36mm offset 0510015 Size 0 38mm offset 0510011 Size 1 38mm offset ISO5832-9 0510012 Size 2 38mm offset 0510013 Size 3 38mm offset 0510014 Size 4 38mm offset 0510005 Size 0 45mm offset 0510001 Size 1 45mm offset 0510002 Size 2 45mm offset 0510003 Size 3 45mm offset 0510004 Size 4 45mm offset * ATTENTION WARNING - AVANTEON cemented hip CDH stem has a weight limit of 56kg and must not be used with femoral heads of more than +4mm neck length. 0510020 Size 1 50mm offset 0510021 Size 2 50mm offset 0510022 Size 3 50mm offset DESCRIPTION CAT. NO Distal Centralizer with Tantulum bead Material Size 10-18mm PMMA 0251018 DESCRIPTION CAT. NO DIAMETER Cement Plug 13-00-10 10mm 13-00-11 11mm 13-00-12 12mm 13-00-13 13mm 13-00-14 14mm 13-00-15 15mm 13-00-16 16mm 13-00-17 17mm 13-00-18 18mm 13-00-19 19mm 13-00-20 20mm 15

CAT. NO HEAD DIAMETER NECK LENGTH 0420002 28mm -3.5 0420012 28mm 0 0420022 28mm + 4 * 0420032 28mm + 8 * ATTENTION WARNING - AVANTEON cemented hip CDH has a weight limit of 56kg and must not be used with femoral heads of more than +4mm neck length. CAT. NO CUP SIZE 0340240 STD 40mm 0340242 STD 42mm 0340244 STD 44mm 0340248 STD 48mm 0340252 STD 52mm Acetabular cups are available as Standard (STD) or Long Posterior Wall (LPW). 0340256 STD 56mm 0340260 STD 60mm 0341240 LPW 40mm 0341242 LPW 42mm 0341244 LPW 44mm 0341248 LPW 48mm 0341252 LPW 52mm 0341256 LPW 56mm 0341260 LPW 60mm 16

Instrumentation 1 2 3 4 5 6 DESCRIPTION CAT NO. 1 Osteotomy Guide 007127 2 Box Osteotome Small 007033 Large 007034 3 Acetabular Step Drill 007042 4 Acetabular Cup Inserter 007036 5 Acetabular Cup Pusher 007047 6 Anteversion Handle 007052 17

1 2 3 4 5 6 7 DESCRIPTION 1 Intramedullary Reamer CAT NO. Small 10mm 007051 Large 14mm 007043 2 Broach CDH 36mm offset 007100 Size 0 38mm offset 007105 Size 1 38mm offset 007101 Size 2 38mm offset 007102 Size 3 38mm offset 007103 Size 4 38mm offset 007104 Size 0 45mm offset 007115 Size 1 45mm offset 007111 Size 2 45mm offset 007112 Size 3 45mm offset 007113 Size 4 45mm offset 007114 Size 1 50mm offset 007120 Size 2 50mm offset 007121 Size 3 50mm offset 007122 3 Broach Handle 007035 4 Trial Necks CDH and 38mm Offset 007128 45mm offset 007016 50mm offset 007017 5 Stem Inserter 007006 6 Femoral Head Impactor 007005 7 Trial Heads Neck Length 28mm - 3.5mm 007018 28mm 0mm 007019 28mm + 4mm 007020 28mm + 8mm 007021 28mm + 12mm 007022 AVANTEON H I P S Y S T E M 18

Mueller Cup Range DESCRIPTION PRODUCT NO. Cemented Acetabular Cup - UHMW polyethylene 28mm I/D 44mm O/D 02-28-04 47mm O/D 02-28-06 50mm O/D 02-28-01 54mm O/D 02-28-08 58mm O/D 02-28-09 62mm O/D 02-28-10 Cemented Acetabular Cup - UHMW polyethylene 32mm I/D 47mm O/D 02-32-06 50mm O/D 02-32-01 54mm O/D 02-32-08 58mm O/D 02-32-09 62mm O/D 02-32-10 Cemented Acetabular Cup - CLP75 highly cross-linked UHMW polyethylene 36mm I/D 50mm O/D 03-50-36 52mm O/D 03-52-36 54mm O/D 03-54-36 56mm O/D 03-56-36 58mm O/D 02-58-36 62mm O/D 03-62-36 Furlong Hemiarthroplasty Heads 12/14 Taper DESCRIPTION PRODUCT NO. Bipolar Heads 40mm O/D 94-40-01 41mm O/D 94-41-01 42mm O/D 94-42-01 43mm O/D 94-43-01 44mm O/D 94-44-01 45mm O/D 94-45-01 46mm O/D 94-46-01 47mm O/D 94-47-01 48mm O/D 94-48-01 49mm O/D 94-49-01 50mm O/D 94-50-01 51mm O/D 94-51-01 52mm O/D 94-52-01 53mm O/D 94-53-01 54mm O/D 94-54-01 56mm O/D 94-56-01 58mm O/D 94-58-01 Physiological Heads 39mm O/D 93-39-01 40mm O/D 93-40-01 41mm O/D 93-41-01 42mm O/D 93-42-01 43mm O/D 93-43-01 44mm O/D 93-44-01 45mm O/D 93-45-01 46mm O/D 93-46-01 47mm O/D 93-47-01 48mm O/D 93-48-01 49mm O/D 93-49-01 50mm O/D 93-50-01 51mm O/D 93-51-01 52mm O/D 93-52-01 53mm O/D 93-53-01 54mm O/D 93-54-01 56mm O/D 93-56-01 58mm O/D 93.58.01 19

Furlong THR Ceramic Femoral Head 12/14 Taper PRODUCT NUMBER HEAD DIAMETER NECK LENGTH 192-28-10c 28mm -4mm 192-28-20c 28mm 0mm 192-28-30c 28mm +4mm 192-28-40c 28mm +8mm 192-32-10c 32mm -4mm 192-32-20c 32mm 0mm 192-32-30c 32mm +4mm 192-32-40c 32mm +8mm 192-36-10c 36mm -4mm 192-36-20c 36mm 0mm 192-36-30c 36mm +4mm 192-36-40c 36mm +8mm 192-40-10c 40mm -4mm 192-40-20c 40mm 0mm 192-40-30c 40mm +4mm 192-40-40c 40mm +8mm Furlong THR CoCr Femoral Heads 12/14 Taper PRODUCT NUMBER HEAD DIAMETER NECK LENGTH 47-28-10 28mm -4mm 47-28-20 28mm 0mm 47-28-30 28mm +4mm 47-28-40 28mm +8mm 47-28-50 28mm +12mm 47-28-60 28mm +16mm 47-32-10 32mm -4mm 47-32-20 32mm 0mm 47-32-30 32mm +4mm 47-32-40 32mm +8mm 47-32-50 32mm +12mm 47-32-60 32mm +16mm 47-36-10 36mm -4mm 47-36-20 36mm 0mm 47-36-30 36mm +4mm 47-36-40 36mm +8mm 47-36-50 36mm +12mm 47-36-60 36mm +16mm 20

Polyethylene CLP75 Bearing Cup Range Standard Liners (I/D) Cup/Reamer size (O/D 44mm 175-44-07 46mm 175-46-07 48mm 175-48-07 50mm 175-50-07 52mm 175-52-07 54mm 175-54-07 56mm 175-56-07 58mm 175-58-07 60mm 175-60-07 62mm 175-62-07 28mm 32mm 36mm 150-44-28 150-46-28 150-48-28 150-48-32 150-50-28 150-50-32 150-52-28 150-52-32 150-54-28 150-54-32 150-56-28 150-56-32 150-56-36 150-58-28 150-58-32 150-58-36 150-60-28 150-60-32 150-60-36 150-62-28 150-62-32 150-62-36 H-A.C. CSF Plus - Liner/ head size combination chart CLP75 Polyethylene Hooded Liners (I/D) 28mm 32mm 36mm 151-44-28 151-46-28 151-48-28 151-48-32 151-50-28 151-50-32 151-52-28 151-52-32 151-54-28 151-54-32 151-56-28 151-56-32 151-56-36 151-58-28 151-58-32 151-58-36 151-60-28 151-60-32 151-60-36 151-62-28 151-62-32 151-62-36 21

CSF Plus Ceramic Bearing Cup Range Cup/Reamer size (O/D 44mm 170-44-07 46mm 170-46-07 48mm 170-48-07 50mm 170-50-07 52mm 170-52-07 54mm 170-54-07 56mm 170-56-07 58mm 170-58-07 60mm 170-60-07 62mm 170-62-07 28mm 32mm 36mm 40mm 150-44-28 140-46-32 140-50-32 140-50-36 140-54-32 140-54-36 140-54-40 H-A.C. CSF Plus - Liner/head size combination chart Biolox delta Ceramic AVANTEON H I P S Y S T E M 22

JRI Services/Education Nurse Training Factory Visits Basic, instructional, and advanced hip courses On demand loan sets In-service technical support Consignment stock audits Instrumentation checks and maintenance Digital PACS and hard-copy X-Ray templates JRI Orthopaedics is wholly owned by Orthopaedic Research UK Manufactured & Distributed by For further information and training resources visit www.jri-ltd.com 18 Churchill Way, 35A Business Park, Chapeltown, Sheffield S35 2PY T: 0114 345 0000 F: 0114 345 0004 W: www.jri-ltd.com 0086 AVANTEON/OPTEC/V1/06/2017