Bisco D.T. LIGHT-POST X-RO ILLUSION

Similar documents
D.T. LIGHT-POST. Instructions for Use. Bisco 0459 D.T. LIGHT-POST X-RO. Radiopaque Translucent Fiber Post System ILLUSION

D.T. LIGHT-POST. Bisco. Instructions for Use. Radiopaque Translucent Fiber Post System. Double Taper

RESINOMER Dual- Bisco. Instructions for Use. Cured Amalgam Bonding/Luting System

ÆLITE Composites. Bisco. Instructions for Use. Light- Cured. U.S. Patent: 6,709,271

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

DUO-LINK UNIVERSAL KIT

ACE ALL-BOND TE. Bisco CE Universal Dental Adhesive System. Dual- Cured

Bisco UNIVERSAL PRIMER

BIS-SILANE. Bisco Instructions for Use. 2-Part Porcelain Primer

ALL-BOND 2. Bisco. Instructions for Use. Universal Dental Adhesive

Flexi-Flange Fiber. Instruction Book for Flexi-Flange Fiber Posts IMPORTANT: Read pages 7 through 12 for Technique first. ESSENTIAL DENTAL SYSTEMS

R.A.P.T.O.R. SYSTEM. Bisco. Instructions for Use. Composite/Porcelain Finishing Burs. U.S. Patent: 5,779,476

Dowel restorations Treatment with a post and core

Table of Contents. Flexi-Overdenture Characteristics

GLUMA Comfort + Desensitizer

RESTORATIONS IN ENDODONTIC. Epita S. Pane Cons Dept FKG USU

Unique. Patented. Tapered. Customizable. PEERLESS.

Endodontics. Lec.7 د. حسن الرماحي 5 th class. Obturation techniques

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

RelyX Unicem Self-Adhesive Universal Resin Cement Frequently Asked Questions

Restorative Resin Cement for Bonding and Masking Tetracycline and Dark Stained Teeth for All Veneers

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

6/1/15. Bonding Ceramic Veneers in What we did? What we do? Using Evidence-Based Dentistry XXXX ?????

Efficient Bonding Protocol for the Insignia Custom Bracket System

Classic Technique Guide

Calibra. Cements. The Simple Choice for Easy Cleanup

illustrated technique guide

Peak. Universal Bond Light Cure Adhesive with Chlorhexidine. With its versatile formulation, Peak Universal Bond is the only adhesive you need.

ProUltra ULTRASONIC SURGICAL TIPS

TABLE OF CONTENTS ADHESIVES/ETCHANTS FLOWABLES/BASE/LINER POST & CORE TECHNIQUE CEMENTS

A new technique for preprosthetic restorations.

Device Technical File

Ultra-Bond Plus. Dual-Cure Restorative Resin Cement Kit. Store Under Refrigeration

A great file. Even better.

Field Guide to the Ultrasonic Revolution

BOCL-01: Bonding Materials Checklist

Transbond PLUS Color Change Adhesive Lunch and Learn

Safety and Simplicity!

G-CEM LinkAce. The new strength in self-adhesive cement

NEW. SpeedCEM. Plus. The self-adhesive resin cement A BIG PLUS FOR ZIRCONIA

Pulpdent Corporation Revision Date: May 6, 2014 Safety Data Sheet

INSTRUCTIONS FOR USE AND CARE

LuxaCoreZ. Core build-ups and post cementation.

DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009

Incognito Appliance System Bonding Protocols Step-by-Step Procedures

Obturation System of Endodontics

Endo Easy Efficient. one file endo. The RECIPROC Technique Steps to Success.

UNICLIP DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM FOR DENTAL USE ONLY. FISDR / F EN / 11 / updated 06/2016 1/7

SpeedCEM Plus. The self-adhesive resin cement A BIG PLUS FOR ZIRCONIA. Ideal for. ZirCAD

Used Products. Multilink Automix. OptraDam. Total Etch. Monobond Plus. MultiCore. TOOTH - Root post - Fiber-reinforced composite - Multilink Automix

Adper Scotchbond SE Self-Etch Adhesive. technical product profile. Adper

Shades: A1, A2, A3, A3.5, A4, B1, B2, B3, C2, C3, C4, D3, DB, OA2, OA3, OA3.5, OB2, Incisal, SL,SLO, SLT, YB

Tools for Endodontic Success

ProUltra Ultrasonic Non Surgical Endo Tips

2. Gap closure and replacement of the missing tooth 35 with directly modelled bridge region 34-36

DiaDent Group International DIA.DENT DiaRoot BioAggregate. Root Canal Repair Material

Instructions For Use

Endodontics. Patented partial heat treatment Improved safety

Colourf low. light cured dental flowable composite

Pulpdent Corporation Revision Date: May 1, 2017 Safety Data Sheet

DENTCA Denture Base II - Directions for Use

Pulpal Protection: bases, liners, sealers, caries control Module C: Clinical applications

Innovative revolutionary approach to root canal preparation

XP BOND. Universal Total-Etch Adhesive. Directions for Use

DENTCA Denture Teeth - Directions for Use

More than 50 Years of Innovation and Clinical Success

Pulpdent Corporation Revision Date: May 1, 2017

Spectrum TPH. Syringe Starter Pack Resin-based dental restorative system. Directions for Use

Pulpdent Corporation Revision Date: May 1, 2017 Safety Data Sheet

CERASMART. The new leader in hybrid ceramic blocks

Pulpdent Corporation Revision Date: January 1, 2014

Pulpdent Corporation Revision Date: January 1, 2014

Practical FotoSan 630 treatment

Integra Miltex. Endodontic Files. Limit uncertainty with the brand you trust

Clinical report. Drs Paul and Alexandre MIARA and F. CONNOLLY COMPOSITE POSTERIOR FILLINGS. How to control. layering? 8 - Dentoscope n 124

Bone Preservation Stem

QuickPro. Instructions for use

A WHOLE NEW DIMENSION OF TOTAL PERFORMANCE.

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

QUARTZ SPLINT. Our fiber expertise is your strength TM.

THREE-DIMENSIONAL OBTURATION

Pulpdent Corporation Revision Date: May 1, 2017

Breakthrough Performance

OPERATING INSTRUCTIONS. Orascoptic DK

Keep. simple. 3M RelyX Cements

EXAIMPLANT HYDROPHILIC VINYL POLYSILOXANE IMPRESSION MATERIAL (FOR DENTAL IMPLANTS) RECOMMENDED INDICATIONS CONTRAINDICATIONS

Integra Flowable Wound Matrix

One cement that can take you just about anywhere! RelyX. Unicem. Self-Adhesive Universal Resin Cement

Meta Dental Corp th Street, Glendale, NY 11385

INNOVATIONS IN THE FIBER POST FIELD:

Our special deals spring & summer. valid until 31st of July vdw-dental.com

Cementation of crowns, bridges, inlays and onlays. Made of conventional porcelain, ceramic, hybrid ceramics or composite resin Cementation of veneers

Approach Patients with Confidence

Case Study. Case # 1 Author: Dr. Suheil Boutros (USA) 2013 Zimmer Dental, Inc. All rights reserved. 6557, Rev. 03/13.

Treatment guidelines Tips and advice. Phone: Fax:

Our special deals spring & summer. valid until 31st of July vdw-dental.com

ExciTE F L I G H T - C U R I N G T O T A L - E T C H A D H E S I V E. ExciTE F DSC D U A L - C U R I N G T O T A L - E T C H A D H E S I V E

TOOTH - Crown - Lithium disilicate - Retentive preparation - Super- and equigingival - Visible margin - Variolink Esthetic - ExciTE F DSC

Endodontics. Endodontic retreatment

Transcription:

Bisco D.T. LIGHT-POST -RO ILLUSION CE0459 Radiopaque Translucent Fiber Post System RTD Patents: EP 1 115 349, EP 0 432 001, EP 1 776 933, U.S. 5,328,372, U.S. 5,890,904 & Patents Pending: PCT/FR 2008/051 IN-165R3 Rev. 9/09 BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 U.S.A. 847-534-6000 1-800-247-3368 CAUTION: U.S. Federal law restricts this device to sale by or on the order of a dental professional.

D.T. LIGHT-POST * ILLUSION * -RO * Radiopaque Translucent Fiber Post System GENERAL INFORMATION D.T. LIGHT-POST ILLUSION -RO posts are constructed from unidirectional, pretensed fibers bound in a resin matrix. This design produces a post with flexural strength exceeding that of metal posts but with a modulus of elasticity very close to that of dentin. The low modulus dissipates stress rather than transferring and concentrating stress in the residual root structures as seen with cast or prefabricated metal posts. The D.T. LIGHT-POST ILLUSION -RO is a color coded post for easy identification. However, the color intrinsically disappears when placed in the canal leaving an aesthetically pleasing translucent post. The color can reappear on demand with a cold water spray to aid with post removal in the event the tooth requires future retreatment. Due to its translucency, BISCO s D.T. LIGHT-POST ILLUSION -RO will transmit light and can be used with light-cured or dual-cured cements and adhesives. This post will intimately bond to the tooth structure and core build-up composite while its passive taper respects morphology and conserves tooth structure. CLINICAL PROCEDURE These instructions must be followed for validation of the optional 6 year limited warranty on D.T. LIGHT-POST ILLUSION -RO. PRECAUTION: Gloves must be worn when handling the D.T. LIGHT-POST ILLUSION -RO since the post fibers may irritate the skin and the oils on the skin may affect the bond strength of the post. NOTE: If bonding agents, cementation materials and core materials, other than those identified in these instructions are used, please refer to the manufacturer s instructions for guidance. With the tooth endodontically treated and filled with gutta-percha, the remaining tooth structure is prepared according to conventional principles. 1. SELECTION OF POST SIZE Posts are available in four different sizes to accommodate a variety of teeth and canal sizes. Drills and posts are color-coded for ease in determining which drill is to be used with each post. It also aids in size identification. Size #0.5 Post: Black Pre-Shaping/#0.5 Drill Size #1 Post and Drill: Red Size #2 Post and Drill: Yellow Size #3 Post and Drill: Blue A. Size and direction of canal is determined by radiographic examination. A mylar radiographic guide showing the various sizes of the posts is included with each system kit.

B. A general recommendation can be followed for post size selection: Post #0.5 Post #1 Post #2 Post #3 Central and lateral mandibular incisors Anywhere else deemed appropriate for this size Central and lateral mandibular incisors Mesial and distal canals of maxillary molars Maxillary and mandibular premolars Mesial canals of mandibular molars Lateral maxillary incisors Distal canals of mandibular molars Palatal canals of maxillary molars Maxillary and mandibular canines Maxillary centrals and canines Palatal canals of maxillary molars Distal canals of mandibular molars Large/wide canals 2. CANAL PREPARATION A. General recommendations for post space preparation: The post should be 2 /3 to 3 /4 of the length of the root. A minimum of 3-5mm of gutta-percha should remain at the apex. Proper isolation must be used. B. Remove gutta-percha with a #1 or #2 Peeso Reamer, #3 Gates Glidden or a heated endodontic plugger. C. Shaping the canal: (1) Use the D.T. Pre-Shaping Drill (black) to complete the preliminary preparation. This instrument determines the final depth to which the post will be placed and serves to guide the final preparation with the subsequent drills. (2) An endodontic rubber stopper on the shaft of the drill should be used as a guide for determining the length of the preparation with radiographic verification. In order to ensure against root perforation while drilling, make sure the drill is always positioned within the canal. (3) Remove debris from the canal with water followed by drying with paper points. D. Final canal preparation: (1) Use the D.T. Drills in order, starting with the smallest, until the desired final size is accomplished. PLEASE NOTE: Posts require the sequential use of the drills as follows: Size #0.5: Use only the Pre-Shaping/#0.5 Drill (black), no additional use of other drills needed. Size #1: Use the Pre-Shaping Drill (black), followed by the size #1 Drill (red). Size #2: Use the Pre-Shaping Drill (black), followed by the size #1 Drill (red), followed by the size #2 Drill (yellow). Size #3: Use the Pre-Shaping Drill (black), followed by the size #1 Drill (red), followed by the size #2 Drill (yellow), then the size #3 Drill (blue). (2) Ideally, the final canal preparation allows sufficient space for the post and 30 microns around the post for bonding materials.

3. DETERMINING POST LENGTH A. Try-in the post and determine the overall length required. B. Remove the post from the canal and cut with a diamond bur or diamond disc. WARNING: Never use pliers to cut the post since the pressure can destroy the structure of the post. In addition, surface alteration of the post (sandblasting or roughening with a bur) is contraindicated. 4. POST CEMENTATION When using DUO-LINK * (Resin Cement) and ONE-STEP */ONE-STEP PLUS (Adhesive) PRECAUTION: Do not clean the canal using hydrogen peroxide as it may inhibit bonding. A. Post Space Preparation: (1) To the canal, apply a phosphoric acid etchant such as UNI-ETCH * w/bac for 15 seconds and rinse with water. (2) Blot the canal with a paper point to remove excess moisture. (3) Apply 2 coats of ONE-STEP/ONE-STEP PLUS to the walls of the canal using an ENDO APPLICATOR. (4) Blot the canal dry with paper points until the paper point returns dry from the canal. PLEASE NOTE: The paper point step is important for removal of any pooled adhesive so that there is no interference in complete seating of the post. (5) Light cure ONE-STEP/ONE-STEP PLUS for a minimum of 10 seconds at 500mW/cm 2. Position the light as close as possible to the canal opening. Light access is necessary for curing ONE-STEP/ONE-STEP PLUS in the canal. B. Post Cementation: (1) Coat the post with ONE-STEP/ONE-STEP PLUS lightly air dry and light cure for 10 seconds at 500mW/cm 2. a. Remove the Dual-Syringe cap and express some material to confirm that the syringe is free of voids. b. Attach the root canal tip to the mixing tip and then attach mixing tip to Dual-Syringe. c. Express DUO-LINK directly into the canal working in an apical to coronal direction. (2) Quickly seat the post into the canal. Maintain firm pressure for 5-10 seconds once the post is seated. (3) Remove excess cement and light cure for 40 seconds at 500mW/cm 2 by placing the light tip on the post. (4) Once the cement has set, proceed with the core build-up.

When using BisCem * (Self-Adhesive Resin Cement) PRECAUTION: Do not clean the canal using hydrogen peroxide or EDTA as it may inhibit bonding. A. Post Space Preparation: (1) Thoroughly rinse the canal with water. (2) Blot the canal dry with paper points. B. Post Cementation: (1) Thinly coat the post with BisCem and then apply BisCem to the canal using the Dual-Syringe: a. Remove the Dual-Syringe cap and express some material to confirm that the syringe is free of voids. b. Attach the root canal tip to the mixing tip and then attach mixing tip to Dual-Syringe. c. Express BisCem directly into the canal working in an apical to coronal direction. (2) Quickly seat the post into the canal. Maintain firm pressure for 5-10 seconds once the post is seated. (3) Remove excess cement. (To aid in excess cement removal, initially light cure the cement for 2 3 seconds). Light cure for 20 30 seconds at 500mW/cm 2 by placing the light tip on the post. (4) Once the cement has set, proceed with the core build-up. 5. CORE BUILD-UP If using LIGHT-CORE * (Light-Cured Core Material) and ONE-STEP/ONE-STEP PLUS (Adhesive) (1) Clean all surfaces that will receive the core material (including the post) with a slurry of pumice and CAVITY CLEANSER * (disinfectant) or pumice and water. Rinse and dry. (2) Etch the tooth structure for 15 seconds using a phosphoric acid etchant, such as UNI-ETCH w/bac. (3) Apply 1 2 coats of ONE-STEP/ONE-STEP PLUS. Gently air dry to evaporate the solvent. Light cure for 10 seconds at 500mW/cm 2. (4) Dispense desired amount of LIGHT-CORE onto a light-protected mixing pad by turning the syringe handle clockwise. NOTE: To prevent excessive material from extruding from syringe, turn handle counterclockwise immediately after the desired amount is dispensed. (5) Place core material into the preparation (and around post) in increments (not to exceed 5mm). (6) Light cure each increment for a minimum of 20 seconds at 500mW/cm 2. (Or a minimum of 30 seconds if using LIGHT-CORE BLUE). 6. FINAL PREPARATION Conventional principles of tooth preparation (with proper ferrule) must be followed for optimal results. Preparation for final restoration must end on sound tooth structure. There must be 1.5mm of sound tooth structure beyond the core material. Positive horizontal and vertical walls should exist.

7. POST REMOVAL The D.T. LIGHT-POST ILLUSION -RO greatly aids in the post removal process in the event retreatment is required. A cold water spray on the post during the removal process causes the color to reappear in the post allowing visibility to ensure the entire post has been fully removed. A D.T. LIGHT-POST REMOVAL KIT is available through BISCO. See POST REMOVAL TECHNIQUE description and instructions available with the D.T. LIGHT-POST REMOVAL KIT. (-80692P) INFECTION CONTROL FOR D.T. LIGHT-POST ILLUSION -RO RECOMMENDED NOT RECOMMENDED DISINFECTION All chemical disinfection solutions CLEANING Alcohol eg. ethanol: 1-5 minutes Boiling Ultrasonic cleaning STERILIZATION Hot air sterilization 120 C Posts must be packed in a sterilization pouch/bag Gas sterilization/chemiclave Steam sterilization/autoclave (max. 134 C) Posts must be packed in a sterilization pouch/bag *Unapproved sterilization may render the post unusable. STORAGE: Store all components except BisCem at room temperature (20 C/68 F - 25 C/77 F). Refrigerate BisCem when not in use (2 C/36 F - 8 C/46 F). DO NOT STORE IN DIRECT SUNLIGHT OR ARTIFICIAL LIGHT. See individual component labels for specific expiration dates. PRECAUTION: Unpolymerized resins may cause skin sensitization in susceptible persons. Avoid contact with the skin. In case of contact with the skin, wash thoroughly with soap and water. Phosphoric acid of UNI-ETCH is a severe eye irritant and tissue irritant. If accidentally instilled into the eye, flush with copious amounts of water and seek medical attention immediately. In case of contact with other tissues, rinse immediately with plenty of water for several minutes. Injury may result if UNI-ETCH is allowed to remain on the skin or mucosa for extended periods of time. WARRANTY: BISCO, Inc. recognizes its responsibility to replace products if proven to be defective. BISCO, Inc. does not accept liability for any damage or loss, either direct or consequential, stemming from the use of or inability to use the products as described. Before using, it is the responsibility of the user to determine the suitability of the product for its intended use. The user assumes all risk and liability in connection therewith. Optional 6 year limited warranty is available. RTD Patents: EP 1 115 349, EP 0 432 001, EP 1 776 933, U.S. 5,328,372, U.S. 5,890,904 & Patents Pending: PCT/FR 2008/051 * D.T. LIGHT-POST and -RO are registered trademarks of RTD France. ILLUSION is a trademark of RTD France. D.T. LIGHT-POST ILLUSION -RO is developed by RTD France. DUO-LINK, LIGHT-CORE and CAVITY CLEANSER are trademarks of BISCO, Inc. ONE-STEP, UNI-ETCH and BisCem are registered trademarks of BISCO, Inc. U.S. only.

BISCO, INC. 1100 W. Irving Park Road Schaumburg, IL 60193 U.S.A. 847-534-6000 1-800-BIS-DENT www.bisco.com EC Representative BISICO France 120 allée de la Coudoulette 13680 Lançon De Provence France Tél : 33-4-90-42-92-92 Manufacturer of Posts/Drills and Accessories: R.T.D., 38120 St. Egreve France Distributor of Posts/Drills and Accessories: BISCO Inc., Schaumburg, IL 60193 U.S.A.