Institutional review board approval was obtained prior to the start of this study.

Similar documents
64-MDCT imaging of the pancreas: Scan protocol optimisation by different scan delay regimes

Assessment of Lower Limb Length and Alignment by Biplanar Linear Radiography: Comparison With Supine CT and Upright Full-Length Radiography

Seemingly isolated greater trochanter fractures do not exist

Computed tomography for the detection of thumb base osteoarthritis, comparison with digital radiography.

Digital tomosynthesis in diagnosis of occult hip fractures

CT Evaluation of Patellar Instability

Long bones manifestations of congenital syphilis

The radiologist and the raiders of the lost image

AFib is the most common cardiac arrhythmia and its prevalence and incidence increases with age (Fuster V. et al. Circulation 2006).

Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures

Scientific Exhibit Authors:

Metal Artifact Reduction by Dual Energy CT

Computed tomographic dacryocystography as compared with X-ray dacryocystography in patients with dacryostenosis

Bolus administration of esmolol allows for safe and effective heart rate control during coronary computed tomography angiography

Basic low - field MR imaging of meniscal injuries in children.

Radiological features of Legionella Pneumophila Pneumonia

Cognitive target MRI-TRUS fusion biopsies of MRI detected PIRADS 4 and 5 lesions

FDG-18 PET/CT - radiation dose and dose-reduction strategy

How to obtain the waist circumference for retrospective studies - a prospective validation of CT images for the evaluation of the abdominal perimeter

Slowly growing malignant nodules and rapidly growing benign nodules: Evaluation of the value of volume doubling time

How to plan a Zenith AAA stent-graft from a CTA: Basic measurements and concepts explained

Shear Wave Elastography in diagnostics of supraspinatus tendon.

Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy

User Guide for Dental and Maxillofacial Cone Beam Computed Tomography (CBCT)

Ultrasonographic evaluation of patellar deviation and its influence on knee muscles and tendons

Quantifying Dual-energy computed tomography (DECT) in patients with renal calculi using a Toshiba Aquilion One Scanner.

High density thrombi of pulmonary embolism on precontrast CT scan: Is it dangerous?

Identification and numbering of lumbar vertebrae using various anatomical landmarks on MRI of lumbosacral spine

Artifact in Head CT Images Due to Air Bubbles in X-Ray Tube Oil

B. CT protocols for the spine

Scientific Exhibit Authors: V. Moustakas, E. Karallas, K. Koutsopoulos ; Rodos/GR, 2

Purpose. Methods and Materials. Results

Monophasic versus biphasic contrast application in CT of patients with head and neck tumour

Comparison of MRI and ultrasound based liver volumetry in iron overload diseases

Imaging Gorham's disease (vanishing bone)

Quantitative imaging of hepatic cirrhosis on abdominal CT images

Computed tomography for pulmonary embolism: scan assessment of a one-year cohort and estimated cancer risk associated with diagnostic irradiation.

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Cierny-Mader classification of chronic osteomyelitis: Preoperative evaluation with cross-sectional imaging

Influence of pulsed fluoroscopy and special radiation risk training on the radiation dose in pneumatic reduction of ileocoecal intussusceptions.

3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy

The effect of CT dose reduction on performance of a diagnostic task

The effect of CT dose reduction on performance of a diagnostic task

Uozu city/jp, Minatoku, Tokyo/JP Bones, Extremities, CT, Surgery, Physics, Artifacts, Image verification /ecr2014/C-0462

MRI grading of postero-lateral corner and anterior cruciate ligament injuries

A time-honored but almost forgotten sign of COPD: sabersheath trachea as a marker of severe airflow obstruction

CT assessment of children with in-toeing gait

Comparison of Image quality in temporal bone MRI at 3T using 2D selective RF excitation versus a routine SPACE sequence

Popliteal pterygium syndrome

Effect of intravenous contrast medium administration on prostate diffusion-weighted imaging

Intratendinous tears of the Achilles tendon - a new pathology? Analysis of a large 4 year cohort.

Diffusion-weighted MRI (DWI) "claw sign" is useful in differentiation of infectious from degenerative Modic I signal changes of the spine

Comparison of radiation doses of various approaches of MR arthrograms with fluoroscopic guided contrast injection

Abdominal fat distribution (subcutaneous vs. visceral abdominal fat compartments): correlation with gender, age, BMI and waist circumference

Significance of MRI in diagnostics, outcome prognosis and definition the therapeutic tactics for cases of aseptic necrosis of the femoral head

Ultra-low dose CT of the acute abdomen: Spectrum of imaging findings

Low-dose computed tomography (CT) protocol in the screening of patients with social exposure to asbestos

A pictorial review of normal anatomical appearences of Pericardial recesses on multislice Computed Tomography.

Computed tomography and Modified RECIST criteria for assessment of response in malignant pleural mesothelioma

CT staging in sigmoid diverticulitis

Postmortem Computed Tomography Finding of Lungs in Sudden Infant Death.

MRI evaluation of TMJ condylar angulations

Multislice CT versus cone beam CT: dosimetric and image quality comparision.

Contrast agents, Abdomen, CT, Contrast agent-intravenous, Cancer /ecr2015/C-1760

Spinal injury is very common in Ireland: 19 per 100,000 (1). It poses a significant disease burden.

Medical device adverse incident reporting in interventional radiology

BI-RADS 3, 4 and 5 lesions on US: Five categories and their diagnostic efficacy and pitfalls in interpretation

Single cold nodule in Graves' disease: benign vs malignant

Is the lateral neck radiograph still a viable investigation for an impacted fish bone in the aero-digestive tract: going back to basics.

Standardizing mammographic breast compression: Pressure rather than force?

Time efficiency of a new server-based post-processing solution (syngo.viatm) for post-processing and reporting of cardiac CT

Valsalva-manoeuvre or prone belly position for computed tomography (CT) scan when an orbita varix is suspected: a single-case study.

The "whirl sign". Diagnostic accuracy for intestinal volvulus.

Intraluminal gas in non-perforated acute appendicitis: a CT sign of gangrenous appendicitis

Imaging acute knee trauma: Are referral criteria and clinical guidelines used in Belgium?

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients

Retrospective review of radiographically occult femoral and pelvic fractures detected by MRI following low-energy trauma.

Imaging Features of Acute Pyelonephritis in Contrast Computed Tomography as Predictors of Need for Intervention

Imaging Features of Acute Pyelonephritis in Contrast Computed Tomography as Predictors of Need for Intervention

The Role of Radionuclide Lymphoscintigraphy in the Diagnosis of Lymphedema of the Extremities

Radiation induced DNA double strand breaks undergoing PET/CT examinations.

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

PGMI classification of screening mammograms prior to interval cancer. Comparison with radiologists' consensus classification.

Resuscitation lateral cervical spine X-ray (LSCX): A useful mandatory screening tool in acute trauma?

Radiological Investigation of Renal Colic in an Emergency Department of a Teaching Hospital

Clinical impact of double reading of thoracic CT

Anatomical Variations of the Levator Scapulae Muscle - an MR Imaging Study

Audit of CT Pulmonary Angiogram in suspected pulmonary embolism patients

MR-guided prostatic biopsy at 3T: the role of PI-RADS-score: a histopahologic-radiologic correlation

"Ultrasound measurements of the lateral ventricles in neonates: A comparison of multiple measurements methods."

MRI in Patients with Forefoot Pain Involving the Metatarsal Region

CT Fluoroscopy-Guided vs Multislice CT Biopsy ModeGuided Lung Biopies:a preliminary experience

Delayed Vertebral Augmentation With Spinejack Technique in A3 Type Vertebral Compression Fractures

Role of ultrasound in the evaluation of the ileocecal valve

Extraarticular Lateral Ankle Impingement

Clinical impact of double reading of abdominal CT scans of surgical patients

Trabecular bone analysis with tomosynthesis in diabetic patients: comparison with CT-based finite-element method

PI-RADS classification: prognostic value for prostate cancer grading

A Randomized Controlled Study to Compare Image Quality between Fenestrated and Non-Fenestrated Intravenous Catheters for Cardiac MDCT

Reporting of Spinal Fractures

Transcription:

Lower Limb Alignment and Length Measurements - Comparison of Computed Tomography, Upright Full-Length Conventional Radiography and Upright Biplanar Linear-Low Dose X-ray Scanner Poster No.: C-1382 Congress: ECR 2012 Type: Scientific Exhibit Authors: R. Guggenberger 1, C. W. A. Pfirrmann 1, K. Pankalla 1, S. Hauser 1, Keywords: DOI: P. Koch 1, F. Buck 2 ; 1 Zürich/CH, 2 Zürich, ZH/CH Arthritides, Technology assessment, Comparative studies, Plain radiographic studies, Digital radiography, CT, Musculoskeletal joint 10.1594/ecr2012/C-1382 Any information contained in this pdf file is automatically generated from digital material submitted to EPOS by third parties in the form of scientific presentations. References to any names, marks, products, or services of third parties or hypertext links to thirdparty sites or information are provided solely as a convenience to you and do not in any way constitute or imply ECR's endorsement, sponsorship or recommendation of the third party, information, product or service. ECR is not responsible for the content of these pages and does not make any representations regarding the content or accuracy of material in this file. As per copyright regulations, any unauthorised use of the material or parts thereof as well as commercial reproduction or multiple distribution by any traditional or electronically based reproduction/publication method ist strictly prohibited. You agree to defend, indemnify, and hold ECR harmless from and against any and all claims, damages, costs, and expenses, including attorneys' fees, arising from or related to your use of these pages. Please note: Links to movies, ppt slideshows and any other multimedia files are not available in the pdf version of presentations. www.myesr.org Page 1 of 11

Purpose To compare lower limb length and alignment angle measurements using computed tomography (CT), upright full-length conventional radiography (CR) and three dimensional (3D) models based on upright biplanar linear low dose radiography (EOS). Methods and Materials Institutional review board approval was obtained prior to the start of this study. Patients 51 patients (22 male, 29 female; mean age 68.8years; range 43-92years) with severe gonarthritis scheduled for implantation of a total knee endoprosthesis were consecutively included given their informed consent. Patients younger than 18 years, with a severe lower limb deformity, paraplegic patients or patients who were unable to stand in an upright position were excluded. As part of the study protocol EOS scans were additionally acquired on the same day. CT-Scans CT was performed using a 40-row multi-detector CT unit (Brilliance 40, Philips, Netherlands). The patient was scanned in supine position with his feet first entering the gantry. Both legs were extended and care was taken to stabilize them in neutral position without any rotation. Ankle joints were flexed in 90 and the toes pointed towards the ceiling. The limb with the diseased knee was centered in the gantry. In order to allow preoperative axial axis measurements of the femur and tibia three spiral scans had to be planned on a scout view from the iliac crest to the planta pedis: first of the hip joints (from pubic joint space to proximal ¼ of the femur), second of the knee joints (15cm above to 10cm below joint space) and third of the ankle joints (5cm above joint space to center of calcaneus). Scout view, raw images and reconstructed data were enventually sent to the PACS for ensuing measurements. CR-Scans Full length conventional radiographs were performed immediately after CT acquisitions on an Ysio-system (Siemens Healthcare). Different presets of tube voltages were chosen by the radiology technician according to patient`s stature and weight (small, medium Page 2 of 11

and large with 75-85kV, 77-90kV and 77-96kV and tube currents according to automatic exposure measurements, respectively). Three differently angulated projections of the lower limb are combined into one single "stitched" image by a specific post-processing algorithm of the unit. The stitched images were then sent to the PACS for length and angle measurements. EOS-Scans All scans were simultaneously performed in frontal and lateral projections in an EOS imaging unit (EOS, EOS imaging SA, 10 rue Mercœur, 75011 Paris, France). The patient was centered in upright position in the scanner on a platform with his central axis aligned with vertical laser lights in frontal and lateral projections. Patients had to be positioned with their legs in a small step position in order to allow delineation of the contour of both limbs on the lateral projection. Tube voltage of the X-ray tubes was chosen by the radiology technician from three presets, according to the patients` weight and stature (small, medium and large; 80-104kV with 200-320 mas for ap-projection and 100-120kV with 200-320mAs for lateral projection). The translational speed of the tubes was chosen between 4 and 6 on the vendor specific scale (ranging from 1 for fast to 8 for slow). After scanning images were sent immediately to the EOS workstation for generation of 3D models. Post-Processing and Measurements All post-processing and measurements were performed by two radiologists. In all modalities lower limb length was defined by calculating the distance from the center of the femoral head to the center of the ankle joint space. Lower limb alignment angle was defined between a line through the center of the femoral head and the intercondylar notch of the femur and a line between the eminentia intercondylaris of the tibia and the center of the ankle joint (Figure 1) [1]. CT and CR Measurements on CT scout view and CR were performed in the PACS-system of our department (IMPAX 6.4.0.4551, Agfa) using the aforementioned predefined structures (Figure 2a-c). EOS EOS acquisitions were post-processed on a separate workstation of the EOS unit using vendor-specific software (stereos 1.4.3.5112). An idealized model of the software was fused with the frontal and lateral projection of the lower limb by manually fitting contours of the model to predefined osseous landmarks (e.g. femoral head, femoral condyles, tibial head, medial and lateral malleolus) (Figure 3a). A 3D model could then be generated and Page 3 of 11

key measurements (limb length and limb alignment angle) were automatically calculated by the software according to the abovementioned definitions (Figure 3b). Statistical Analysis Descriptive statistics (mean, standard deviation (SD) and range) were calculated for both lower limb length and alignment angles of the three different modalities. Differences between modalities were assessed by paired, two-tailed t-testing and Bland- Altman analyses. Inter-reader agreement was assessed by calculating intraclass correlation coefficients (ICC) for all modalities. ICC values of 0.61-0.80 were interpreted as substantial, and 0.81-1 as high agreement. A p-value of 0.05 was considered statistically significant. Images for this section: Page 4 of 11

Page 5 of 11

Fig. 1: Figure 1: In all modalities lower limb length was defined by calculating the distance from the center of the femoral head to the center of the ankle joint space (left leg). Lower limb alignment angle was defined between a line through the center of the femoral head and the intercondylar notch of the femur and a line between the eminentia intercondylaris of the tibia and the center of the ankle joint (right leg). Fig. 2: Figure 2: Measurements of limb length and alignment angle were performed on CT scout view (a), CR (b) and EOS (c) using the aforementioned predefined structures (center femoral head, intercondylar notch of femur, eminentia intercondylaris of the tibia and the center of the ankle joint). Page 6 of 11

Fig. 3: Figure 3: EOS acquisitions were post-processed on a separate workstation of the EOS unit using vendor-specific software (stereos 1.4.3.5112). An idealized model of the software was fused with the frontal and lateral projection of the lower limb by manually fitting contours of the model to predefined osseous landmarks (e.g. femoral head, femoral condyles, tibial head, medial and lateral malleolus) (a). A 3D model could then be generated and key measurements (limb length and limb alignment angle) were automatically calculated by the software according to the abovementioned definitions (b). Page 7 of 11

Results Mean limb lengths were 783.4mm (SD± 55.77mm, range 639-927mm), 784.7mm (SD ±53.56mm, 655-924mm) and 779.4mm (SD±55.28mm, 633-921mm) for CT, CR and EOS, respectively. Mean alignment angle measurements were 2.2 (SD±5.50, range -12-20 ), 2.5 (SD±6.89, -17-18 ) and 3.7 (SD±6.62, -14-18 ), respectively (Table 1). Length and angle measurements differed significantly when comparing EOS to CT and CR by paired t-testing (p<0.001). However, no significant differences were seen between CT and CR for length and angle measurements, respectively (p= 0.328 and 0.562). Bland-Altman analyses showed a small positive bias in length (3.94mm, SD±3.97; 5.25mm, SD±13.32) and a small negative bias in angle measurements (-1.41, SD±2.52; -1.21, SD±3,43) for CT and CR compared to EOS (Figure 4, Table 2). A constant range of measurment differences and scatter in the graphs wih increasing average was seen in comparisons and for both length and alignment angle measurements. Furthermore consistent variability of measurements across all graphs was seen. ICCs for interreader agreements were 0.996, 0.996 and 0.997 for limb length and 0.949, 0.933 and 0.952 for angle measurements in CT, CR and EOS respectively (Table 3). Images for this section: Page 8 of 11

Table 1: Table 1: Descriptive Statistics of mean lower limb length and alignment angle measurements for different imaging modalities and both readers. Fig. 4: Figure 4: Bland-Altman analysis of lower limb length (a-c) and lower limb angle alignment (d-f) measurements. Note constant range of measurment differences wih increasing average and consistent variability across all graphs. For detailed values refer to Table 2. Page 9 of 11

Table 2: Table 2: Bland-Altman analyses of different modalities (CT vs CR, CT vs EOS and CR vs EOS) for lower limb length and alignment angle measurements. Table 3: Intraclass correlation coefficients (ICC) of different modalities for calculation of interreader agreement between both readers. Page 10 of 11

Conclusion Lower limb length and alignment measurements on CT, CR and EOS are comparable, however with a significant but small bias in favor of EOS scans. Interreader agreement is high for all modalities with the highest agreement in EOS. References [1] Sabharwal S, Zhao C, McKeon JJ, McClemens E, Edgar M, Behrens F (2006) Computed radiographic measurement of limb-length discrepancy. Full-length standing anteroposterior radiograph compared with scanogram. The Journal of bone and joint surgery. American volume, 88(10):2243-2251. doi: 10.2106/JBJS.E.01179 Personal Information Page 11 of 11