Technique Guide Small Bone Fusion System

Similar documents
Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Lapidus Arthrodesis System Instructions for Use

Technique Guide Lapidus Arthrodesis System

Technique Guide KISSloc Suture System

WristMotion Wrist Hemiarthroplasty System Instructions for Use

Technique Guide Wrist Hemiarthroplasty System

Description Materials Indications Patient selection factors to be considered include: Contraindications Absolute contraindications include:

Hip Resurfacing System

Talar Dome System Surgical Technique

Technique Guide Hip Resurfacing System

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

OPERATIVE TECHNIQUE. CONSTRUX Mini PTC. Mini PTC Spacer System

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

Headless Compession Screw 2.5 / 3.0

Revision A Date:

Precautionary Statement ( )

Technique Guide Hammertoe Correction System

TM TM Surgical Technique

Flexible Fragment Fixation. Surgical Technique

HawkeyeTM Peek. surgical technique

IMPORTANT MEDICAL INFORMATION Advanced Orthopaedic Solutions INTRAMEDULLARY NAILS Warnings and Precautions (SINGLE USE ONLY)

INnate. Surgical Technique Guide. Anatomic Fixation in Your Hands. The INnate Implant

MetaFix Ludloff Plate

Correction System. Surgical Technique

Metallic Internal Fixation Devices The following languages are included in this packet:

Positioning Sleeve Surgical Technique

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

D. The following factors are of extreme importance to the eventual success of the procedure.

INTELLIGENT SPINAL SYSTEM

EVOLVE TRIAD BONE SCREWS

nva Anterior Lumbar Interbody Fusion System

OPERATIVE TECHNIQUE. anterior cervical plating system

Surgical Technique. Apache Anterior Lumbar Interbody Fusion

EXTERNAL FIXATION SYSTEMS The following languages are included in this packet:

nvp Posterior Lumbar Interbody Fusion System

nvt Transforaminal Lumbar Interbody Fusion System

EVOLVE TRIAD SYSTEM

SURGICAL TECHNIQUE GUIDE TRESTLE. Anterior Cervical Plating System

Apache Cervical Interbody Fusion Device. Surgical Technique. Page of 13. LC-005 Rev F

DARCO MIS FOREFOOT SCREW

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

SMV Scientific Bone Plate and Screw System Surgical Technique

Glenoid Resurfacing Technique Guide

Table of Contents.

Technique Guide Glenoid Latarjet System

Gallery Laminoplasty Spine System

Zimmer Anterior Buttress Plate System. Surgical Technique

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Royal Oak Cervical Plate System

MICA SCREWS For additional information and translations please contact the manufacturer or local distributor.

Veyron -C Anterior Cervical System Surgical Technique

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

The following languages are included in this packet:

Asnis. Micro Cannulated screw system. Xpress operative technique

DISTAL RADIUS. Instructions for Use

SURGICAL TECHNIQUE GUIDE: JONES FRACTURE USING THE PRECISION JONES FRACTURE SCREW SYSTEM

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

100 Interpace Parkway Parsippany, NJ

product overview Implant heights range from 8mm-20mm in 2mm increments, with two lordocic angle options of 6 and 12.

3.5 mm LCP Olecranon Plates

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

Hallux Valgus Deformity OPERATIVE TECHNIQUE

X-spine Aranax Anterior Cervical Plating System Instructions for Use / Package Insert

Foot & Ankle. Smart Toe II. Intramedullary Implant. Operative Technique. Foot & Ankle

LBL-014. Rev

Duraloc CONSTRAINED LINER

Integra Total Foot System 2

CHARLOTTE. 3.0 and 4.3 Multi-Use Compression Screws SURGIC A L T ECHNIQUE

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Page 1 of 7 Doc. No.: IU/15 Rev. No.: 05 Rev. Date:03MAY2018. Instructions for use for ATLAS Tibial Fracture(TF) Nail

BONE GRAFT WASHER _Rev A IMPORTANT INFORMATION ON THE BONE GRAFT WASHER

PRO-DENSE BONE GRAFT SUBSTITUTE

3 Operative Technique U.S. EDITION

ACP. Anterior Cervical Plate System SURGICAL TECHNIQUE

Alamo C. Cervical Interbody System Surgical Technique. An Alliance Partners Company

Low Bend Distal Tibia Plates

The following languages are included in this packet:

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

CLAW II POLYAXIAL COMPRESSION PLATING SYSTEM

Important Information on ATLAS Hip Fracture Nail For use by an Accredited Orthopaedic Surgeon only

Correction System. Surgical Technique

3.5 mm Locking Attachment Plate

MPJ Implant System. Patents Pending Worldwide

Integra. Proximal Humeral Fracture Plate System SURGICAL TECHNIQUE

METAL HEMI SYSTEM

X-spine Systems, Inc. Silex Sacroiliac Joint Fusion System

X-spine Systems, Inc. Axle Interspinous Fusion System

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

ENDO-FUSE INTRA-OSSEOUS FUSION SYSTEM The following languages are included in this packet:

ACP1 CERVICAL PLATE SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE II.

Peanut Growth Control Plating System

Instructions for use for Bone Plates, Bone Screws, Intramedullary Nails, Pins and Wires

TC-PLUS Primary Knee IMPORTANT MEDICAL INFORMATION SPECIAL NOTE. This Package Insert is for product distributed in the US only.

3.0 mm Cannulated Screw System. Surgical Technique

Surgical Technique Carpal Fusion

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

Progeny Hip Stem. Surgical Protocol and Product Specifications

Surgical Technique 4.5/8.5MM BEAMING SYSTEM. Customer Service:

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Transcription:

Technique Guide Small Bone Fusion System The Pinit Plate Small Bone Fusion System is a super low profile, modular bone plate and screw system designed to stabilize a bunionectomy with a medial to lateral approach. The system is available in multiple size options for fracture fixation, osteotomies, reconstruction or arthrodesis of small bones and joints in the upper and lower extremities. 2-Point Bicortical Screw Fixation Avoids Contact with Sesamoids No Splitting/Fracture of Dorsal Cortex No Measuring Through Osteotomy Site Complete sterile and disposable off-the-shelf kit

Description The Pinit Plate Small Bone Fusion System consists of 2-hole bone plates made available in three length options (8 mm, 12 mm, 14 mm hole-to-hole), two thickness options (0.8 mm and 1.6 mm) and 2.0 mm diameter bone screws having lengths varying from 8 mm to 24 mm (in 2 mm increments). The bone plate is pre-assembled with a suture loop intended to provide traction force required to achieve compression between bone segments. The bone screws have a snap-off feature designed to work with the plate and/or as a stand alone fixation fastener. All implant components are manufactured from implant grade stainless steel. Materials Bone Plates: Bone Screws: Suture: Surgical Instruments: 316L Stainless Steel 316L Stainless Steel Ultra High Molecular Weight Polyethylene Medical Grade Stainless Steel and High Temperature Plastics Indications For Use Intended for the treatment of fracture fixation, osteotomies (ex. Akin, Chevron, Scarf, Weil), reconstruction, revision surgery and arthrodesis of small bones in the upper and lower extremities. 2

Surgical Technique These illustrations demonstrate the use of the Pinit Plate system for the case of a chevron bunionectomy. The steps will remain the same for other osteotomies, arthrodesis or fracture fixation cases. 1. Use the Measuring Guide over the implant site to determine appropriate Bone Plate length and Bone Screw length. Note: It may be necessary to determine the Screw length on either side of the fracture or osteotomy. Bone Plate Measurement Bone Screw Length Measurement 2. Insert the Snap-Off Screw into a self-retaining pin/wire driver to engage it at the shaft. Note: Improper handling or engaging the driver chuck in close proximity to the Screw may cause damage and render it unusable. 3

3. Place the Screw inside the Plate hole not containing the suture (distal hole). Power drive the Screw into distal bone segment while keeping the suture in tension proximally. Note: Apply tension as necessary to avoid spinning of the Plate while driving the Screw into bone. 4. Bend or tilt the pin/wire driver away from the centre axis to snap-off the shaft from the Screw head once the Plate is in contact with bone, and the Screw head is seated flush with the Plate. Note: Over driving or excessive spinning of the Screw within the bone will lead to stripping of threads and poor fixation. The hand held Screw Driver may be used to adjust final placement of the Screw. 4 Screw Driver

5. Apply traction or compression force proximally with help of suture to close gap between the two bone segments across the osteotomy site. Drive the second appropriate length Snap-Off Screw using a pin/wire driver into proximal Plate hole while maintaining tension on the suture until the Screw head is seated flush with Plate. 6. Snap-off the shaft from the Screw head and use the hand held Screw Driver to adjust screw position if necessary. Remove the suture from final construct and discard. Intra-operative fluoroscopy is recommended to confirm final device placement. Note: Additional stability can be acheived if desired by inserting a Snap-Off Screw across the osteotomy site. 5

Warnings & Precautions Pre-operative and operative procedures, including knowledge of surgical technique, proper selection and placement of implant components are important considerations in the successful utilization of the Pinit Plate Small Bone Fusion System. The potential for success in joint fusion and/or fracture fixation is increased by proper implant selection. The patient s anatomy and indication will determine the size of the bone plate and screws to be used. The size and shape of human bones presents limitations on the size and strength of the implant components. To achieve desired outcomes with the Pinit Plate Small Bone Fusion System, pre-operative patient evaluation is extremely important. Patient s weight, occupation, activity level, mental condition, foreign body sensitivity and any degenerative diseases are important factors to consider. These conditions must be evaluated as a part of the pre-operative planning. The Pinit Plate Small Bone Fusion System implant components are manufactured from metal, and CANNOT be expected to withstand the range of motion, activity level and loads experienced by normal, healthy bone. These implants are intended to be used as a guide to normal healing, and not to replace normal body structure. It is very important to maintain the implant site in an immobilized state until bony union is confirmed via clinical or radiographic examination. Failure to do so will result in excessive and repeated stresses being placed on implant components, which can lead to bending or breaking of the implants due to normal metal fatigue. The presence of motion or forces across the fusion site in cases of delayed union or nonunion may lead to implant bending or breakage due to metal fatigue. All surgical implants are subjected to repeated stresses that can result in failure. The use of an implant should be avoided if excessive loading cannot be prevented at or near the implant site. Post-operative care is extremely important. The surgeon must warn the patient against noncompliance with post-operative instructions, which could lead to implant bending or breakage requiring a revision surgery and/or implant removal. Accepted practices in post-operative care should be used. The patient is to be instructed and monitored to ensure a reasonable degree of compliance to post-operative instructions and activity restrictions. Excessive activity, impact, and weight gain have been implicated in the reduction of the benefit and service life of prosthetic devices. Correct implant handling is extremely important for successful outcomes. Implant components should not be bent, reverse bent, notched or scratched. All of these operations can produce defects in the surface finish and cause internal stress concentrations, which may become the focal point for eventual failure of the implant system. No other metallic or non metallic implantable devices are to be used in conjunction with the Pinit Plate Small Bone Fusion System at the implant site. Doing so may compromise implant performance and patient safety. No implant component must be reused. The Pinit Plate Small Bone Fusion System implant components are Single Use devices that have not been designed to undergo or withstand any form of alterations, such as disassembly, cleaning or re-sterilization, after single patient use. Reuse can eventually compromise implant performance and patient safety. Implant removal is at the sole discretion of the surgeon. Whenever possible and practical for the individual patient, the Pinit Plate Small Bone Fusion System implant components should be removed once their service as an aid to the healing process is accomplished, particularly in younger and more active patients. Great care must be taken while removing the implant components. The Pinit Plate Small Bone Fusion System should be inspected by surgeon or surgical staff prior to use for any signs of wear or damage. Any discrepancies, damages or other issues with the packaging, labeling or implant components should be reported and brought to the notice of the manufacturer. The Pinit Plate Small Bone Fusion System (bone plates and bone screws) has not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating or migration in the MR environment. Unless otherwise noted, the patient should employ adequate external support and restrict physical activities that may lead to stresses being placed on the implant components or allow motion at the fusion site and thus lead to delayed healing. An active, debilitated or demented patient who cannot properly utilize weight support devices may be at higher risk during post-operative rehabilitation. 6

Possible Adverse Effects Loosening, bending, cracking or fracture of the bone plate and bone screws attributable to malunion, nonunion or osteoporosis. Loss of anatomic position with malunion or nonunion with rotation or angulation. Infection, both deep or superficial, or allergic reaction. Material sensitivity reactions. Implantation of foreign material in tissues can result in histological reactions. Particulate wear debris and mild tissue discoloration from metallic components have been noted in other prosthetic devices constructed from similar materials. Some types of wear debris have been associated with osteolysis and implant loosening. Embolism Tissue reactions such as macrophage and foreign body reaction at or near implant site. Fretting or crevice corrosion can occur at the interface of bone plate and bone screws. Fatigue fracture of the implants as a result of bone resorption around the implant components. Intraoperative or postoperative bone fracture. Post-operative pain or incomplete resolution of preoperative symptoms. Sterility The Pinit Plate Small Bone Fusion System components i.e. bone plates, bone screws and instruments are individually packaged and provided STERILE. All components are sterilized by exposure to gamma irradiation. Do not resterilize any components. Do not use if packaging is opened or damaged. Do not use if beyond expiration date. For Single Use Only. Caution Federal Law (USA) restricts this device to sale by or on the order of a physician. Instrumentation Gauge Kit 20mm 8mm 14mm 10mm 12mm 16mm 18mm 22mm 24mm Screw Driver 7

Catalog Numbers Plates Screws 9A0P-1A08 0.8mm thick, Plate, 8mm length 9A2A-B008 Screw, Snap-off, 8mm 9A0P-1A12 0.8mm thick, Plate, 12mm length 9A2A-B010 Screw, Snap-off, 10mm 9A0P-1A14 0.8mm thick, Plate, 14mm length 9A2A-B012 Screw, Snap-off, 12mm 9A0P-2A08 1.6mm thick, Plate, 8mm length 9A2A-B014 Screw, Snap-off, 14mm 9A0P-2A12 1.6mm thick, Plate, 12mm length 9A2A-B016 Screw, Snap-off, 16mm 9A0P-2A14 1.6mm thick, Plate, 14mm length 9A2A-B018 Screw, Snap-off, 18mm 9A2A-B020 Screw, Snap-off, 20mm Instruments 9A2A-B022 Screw, Snap-off, 22mm 9A09-3000 Gauge Kit 9A09-4000 Screw Driver 9A2A-B024 Screw, Snap-off, 24mm PATENTS PENDING Pinit is a trademark of Arthrosurface, Inc. U.S. 2014 Arthrosurface, Inc. All rights reserved. Printed in U.S.A. For more information, visit our website: www.arthrosurface.com 28 Forge Parkway Franklin, MA 02038 1 508 520 3003 fax: 1 508 528 3785 This pamphlet and information is intended for markets where regulatory approval has been granted. PN 4001-3006 REV C