Deposited on: 11 February 2010

Similar documents
Deposited on: 24 February 2009

RESPIRATION AND THE AIRWAY Comparison of the i-gel with the cuffed tracheal tube during pressure-controlled ventilation

I - Gel Versus Cuffed Tracheal Tube in Elective Laparoscopic Cholecystectomy A Clinical Comparative Study

I-gel vs cuffed tracheal tube during volume controlled ventilation in elective laparoscopic cholecystectomy

ISSN X (Print) Research Article. *Corresponding author Dr. Souvik Saha

Comparison of the i-gel and the LMA-Unique laryngeal mask airway in patients with mild to moderate obesity during elective short-term surgery

Other methods for maintaining the airway (not definitive airway as still unprotected):

A randomised comparison between Cobra PLA and classic laryngeal mask airway and laryngeal tube during mechanical ventilation for general anaesthesia

Citation British journal of anaesthesia, 104. pp ; 2010 is available onlin

Randomised comparison of the LMA Supreme with the I-Gel in spontaneously breathing anaesthetised adult patients

University of Groningen

A Comparative Study of Classic LMA and Proseal LMA in Paralyzed Anaesthetized Patients

ISPUB.COM. M Roberts, M Mani, A Wilkes, E Flavell, N Goodwin INTRODUCTION

The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients

ORIGINAL ARTICLE. Shashank Chitmulwar, MD, Charulata Deshpande, MD, DA ABSTRACT. ANAESTHESIA, PAIN & INTENSIVE CARE

AIRWAY MANAGEMENT AND VENTILATION

COMPARATIVE CLINICAL EVALUATION OF PROSEAL LMA WITH I - GEL AIRWAY IN PATIENTS UNDERGOING ELECTIVE SURGICAL PROCEDURES UNDER GENERAL ANAESTHESIA

A Comparative Study of Two Disposable Supraglottic Devices in Diagnostic Laparoscopy in Gynecology

A comparative study between i-gel and classical laryngeal mask airway in elective surgery under general anaesthesia

Received 1 November 2009 Revised 8 December 2009 Accepted 10 December 2009

Comparison of the LMA Supreme vs the i-gel TM in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation*

Comparison of Three Disposable Extraglottic Airway Devices in Spontaneously Breathing Adults

Dr. Ranjeet Rana De 1, Dr. Saurav Shekhar 2, Dr. D G Pathak 3, Dr. Harshwardhan 4, Dr. Shashank Dhiraj 5 1,2,4,5

CONTINUING EDUCATION IN HONOR OF NORMAN TRIEGER, DMD, MD

Comparison of the efficacies of I-gel TM and LMA-ProSeal TM for airway management in pediatric patients

Comparison of clinical performance of i-gel with laryngeal mask airway pro-seal in elective surgery in adults

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

I-GEL TM VS. AURAONCE TM LARYNGEAL MASK FOR GENERAL ANAESTHESIA WITH CONTROLLED VENTILATION IN PARALYZED PATIENTS

The Laryngeal Mask and Other Supraglottic Airways: Application to Clinical Airway Management

Tibe ProSeal Laryngeal Mask Airway

British Journal of Anaesthesia 82 (5): (1999)

LMA Supreme Second Seal. Maintain the airway. Manage gastric contents. Meet NAP4 recommendations.

Comparison of I-gel with Baska Mask Airway for Controlled Ventilation in Obese Patients Undergoing Ambulatory Surgery: A Prospective Randomized Trial

DIFFICULT AIRWAY MANAGMENT. Dr.N.SANTHOSH KUMAR MD ANESTHESIA (2 nd Yr)

Original Contributions

Cricoid pressure: useful or dangerous?

Clinical Study Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults

International Journal of Health Sciences and Research ISSN:

Anatomy and Physiology. The airways can be divided in to parts namely: The upper airway. The lower airway.

Use of the Intubating Laryngeal Mask Airway

JMSCR Vol 4 Issue 02 Page February 2016

A Comparative Study of Supreme LMA Vs I-gel: Two Supraglottic Airway Devices in Short Surgical Procedures

Unanticipated difficult tracheal intubation - during routine induction of anaesthesia in an adult patient

Recent Advances in Airway Management HA Convention 2014

Comparison of the Baska â mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery

RESPIRATION AND THE AIRWAY. Editor s key points. L. Theiler 1,2 *, M. Kleine-Brueggeney 1,3, N. Urwyler 1,4,T.Graf 1, C. Luyet 1 and R.

Optimal Size AMBU Laryngeal Mask Airway Among Asian Adult Population

Airway Management. Teeradej Kuptanon, MD

Similar oropharyngeal leak pressures during anaesthesia with i-gel TM, LMA-ProSeal TM and LMA-Supreme TM Laryngeal Masks

Use of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway

EUROANESTHESIA 2007 Munich, Germany, 9-12 June 2007

Airway/Breathing. Chapter 5

Evaluation of Baska Mask Performance in Laparoscopic Cholecystectomy

A prospective randomized study comparing the efficacy of the LMA Classic TM, the

Comparison between i-gel airway an the proseal laryngeal mask airway in pediatric patients undergoing general anesthesia

Comparative evaluation of Ambu AuraGain with ProSeal laryngeal mask airway in patients undergoing laparoscopic cholecystectomy

Asai and Shingu Table 1 Size selection and recommended cuff volumes Size Patients Body size Recommended cuff volumes (ml) Connector colour 0 Newborn <

Comparisonof Classic- Laryngeal Mask Airway with I-Gel Airway,during Anaesthesia with Controlled Ventilation in Routine Surgical Procedures

Clinical Study Performance of Size 1 I-Gel Compared with Size 1 ProSeal Laryngeal Mask in Anesthetized Infants and Neonates

Airway Management & Safety Concerns Experience from Bariatric Surgery

Comparison of efficacy of the Laryngeal tube with the Laryngeal mask airway in securing the upper airway

Randomized Comparison of Actual and Ideal Body Weight for Size Selection of the Laryngeal Mask Airway Classic in Overweight Patients

Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery

Comparison of Ease of Insertion and Hemodynamic Response to Lma with Propofol and Thiopentone.

A Clinical Comparative Study Of Evaluation Of Proseal LMA V/S I-GEL For Ease Of Insertion And Hemodynamic Stability; A Study Of 60 Cases

REVISTA BRASILEIRA DE ANESTESIOLOGIA

We will not be using the King LTS-D in our system!

Observation of ventilation effects of I-gel TM, Supreme TM and Ambu AuraOnce TM with respiratory dynamics monitoring in small children

Airway/Breathing. Chapter 5

Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff*

Comparision of Hemodynamic Changes after Insertion of Classic Lma and Proseal Lma

Materials and Methods

The effect of head rotation on efficiency of ventilation and cuff pressure using the PLMA in pediatric patients

In 2011 I received an unrestricted lecture honorarium from Ambu I have been loaned equipment by Intavent Direct (Teleflex) and Aircraft Medical As an

Airway Management and The Difficult Airway

LEVITAN S FIBREOPTIC STYLET: BEYOND BARRIERS. - Our Perspective.

Airway Management. Key points. Rapid Sequence Intubation. Rapid Sequence Intubation Recognizing difficult airway Managing difficult airway

Airway Anatomy. Soft palate. Hard palate. Nasopharynx. Tongue. Oropharynx. Hypopharynx. Thyroid cartilage

Cricoid pressure impedes placement of the laryngeal mask airway

Bronchial mucus transport velocity in patients receiving desflurane and fentanyl vs. sevoflurane and fentanyl

Angkana Lurngnateetape,, MD. Department of Anesthesiology Siriraj Hospital

Equipment: NRP algorithm, MRSOPA table, medication chart, SpO 2 table Warm

Blind Insertion Airway Devices (BIAD)

12/15/2010. Presented by: Jim Fox EMT-PS EMS-I EMS Assistant Coordinator Des Moines Fire Department

student handbook BARS handbook September 2012.indd Front Cover 27/11/12 12:08 PM

Gastroesophageal regurgitation during anesthesia and controlled ventilation with six airway devices

Buyers guide. Laryngeal masks CEP 08010

Clinical Study McGrath Video Laryngoscope May Take a Longer Intubation Time Than Macintosh Laryngoscope

Editor s key points. M. Kleine-Brueggeney 1,2, L. Theiler 1,3 *, N. Urwyler 1,4, A. Vogt 1 and R. Greif 1

Nicolette Mosinski MPAS, PA-C

1 Chapter 40 Advanced Airway Management 2 Advanced Airway Management The advanced airway management techniques discussed in this chapter are to

Chapter 40 Advanced Airway Management

Airway Workshop Lecture. University of Ottawa

The flexible laryngeal mask airway (FLMA) was

i-gel TM supraglottic airway in clinical practice: a prospective observational multicentre study

British Journal of Anaesthesia 100 (4): (2008) doi: /bja/aen002 Advance Access publication January 31, 2008

Advanced Airway Management. University of Colorado Medical School Rural Track

Tracheostomy and laryngectomy airway emergencies: an overview for medical and nursing staff

Laryngeal mask airway (LMA-ProSeal) malfunction causing acute airway obstruction

Joint Theater Trauma System Clinical Practice Guideline

Transcription:

Uppal, V. and Gangaiah, S. and Fletcher, G. and Kinsella, J. (2009) Randomized crossover comparison between the i-gel and the LMA- Unique in anaesthetized, paralysed adults. British Journal of Anaesthesia, 103 (6). pp. 882-885. ISSN 0007-0912 http://eprints.gla.ac.uk/8715/ Deposited on: 11 February 2010 Enlighten Research publications by members of the University of Glasgow http://eprints.gla.ac.uk

1 Randomised crossover comparison between the i-gel and the LMA Unique in anaesthetised, paralysed adult patients V Uppal 1 *, S Gangaiah 1, G Fletcher 2 and J Kinsella 1 1 Section of Anaesthesia, Pain and Critical Care, Faculty of Medicine, University of Glasgow, UK. 2 Department of Anaesthesia, Royal Alexandra Hospital, Paisley, UK *Corresponding author. E-mail: drvishal76@rediffmail.com

2 Summary Background. The i-gel differs from other supraglottic airway devices in that it has a softer and a non-inflatable cuff. This study was designed to compare the performance of the i-gel and the LMA Unique when used during anaesthesia in paralysed patients. Methods. The devices were studied in 39 anaesthetised, paralysed patients by randomized crossover trial. The primary outcome was airway leak pressure. Secondary outcomes included the time for insertion, the number of insertion and reposition attempts, leak volumes and leak fractions. Results. There was no significant difference between the airway leak pressures of the two devices (median [IQR] values, i-gel 25 [22-30] cm H 2 O and LMA Unique 22 [20-28] cm H 2 O; p = 0.083). The median [IQR] insertion time for the i-gel (12.2 [9.7-14.3] s) was significantly less than for the LMA Unique (15.2 [13.2-17.3] s; p = 0.007). All the LMA Uniques and 38/39 i-gels were inserted at the first attempt. The number of manipulations required after insertion to achieve a clear airway was same in both the groups (four in each). There were no statistically significant differences in the leak volumes or leak fractions during controlled ventilation. Conclusions. We were unable to demonstrate any difference in efficacy of seal and success rate of first-time insertion between the i-gel and the LMA Unique although the insertion times for the i-gel are significantly shorter when compared to the LMA Unique. We conclude

3 that the i-gel provides a reasonable alternative to the LMA-U for controlled ventilation during anaesthesia. Keywords: equipment, airway; equipment, masks, laryngeal; ventilation, mechanical

4 The i-gel (Intersurgical Ltd, Wokingham, UK) is a relatively new, single use supraglottic airway device (SAD) designed for use during anaesthesia. 1 Unlike the conventional LMAs it does not have an inflatable cuff. The i-gel is made from a soft, gel-like, and transparent medical grade thermoplastic elastomer (Styrene Ethylene Butadiene Styrene). The cuff has been designed to create a non-inflatable anatomical seal by a shape which is a mirror impression of the supraglottic anatomy. A studies performed on manikins showed that the insertion of the i-gel was significantly easier when compared with insertion of other SADs. 2 There is evidence to suggest that it is easier to train non-anaesthetists how to correctly insert i-gels, compared with the conventional SADs, thus making it a potentially useful device for situations such as resuscitation. 3-5 Recent studies show that the i-gel provides a good seal during anaesthesia for spontaneously breathing patients as well as for controlled ventilation. 6 8 We are unaware of any published studies performed on live humans which have compared its performance with other well established SADs for controlled ventilation. LMA Unique (LMA-U; Intavent Orthofix, UK) is the single-use form of the LMA classic. This study was designed to compare the adequacy of seal and ease of insertion of the i-gel and the LMA-U during anaesthesia in paralysed patients.

5 Methods After obtaining approval from the Local Research Ethics Committee and written informed consent, we recruited 40 adult patients to a prospective randomised crossover clinical trial. Patients undergoing elective surgery that involved tracheal intubation were recruited to the study. Patients, ASA I II, age 16 70 yr, who had the ability to give informed consent, were included in the study. The exclusion criteria were presence of any significant acute or chronic lung disease, pathology of the neck or upper respiratory tract, potential difficult intubation, an increased risk of aspiration (hiatus hernia, gastro-oesophageal reflux, or full stomach), pregnant women, BMI>35 kg.m -2 and patients unable to communicate in English. We used the Datex-Ohmeda Aestiva/5 anaesthetic machine (GE Healthcare) with its built-in pressure gauge and spirometer attachment for the study. Before induction of anaesthesia, the anaesthetic machine and circuits were checked as per manufacturer s guidelines. Intravenous access was secured and standard monitoring, including a peripheral nerve stimulator, was attached. After preoxygenation, anaesthesia was induced with fentanyl 1 microgram.kg -1 and a target control infusion (TCI) of propofol to achieve a target plasma concentration of propofol to 4 7 microgram.ml -1. On loss of verbal contact, the anaesthetist checked that the patient could be hand-ventilated with a facemask. A bolus dose of rocuronium 0.5 mg.kg -1 was then given. Neuromuscular blockade was confirmed using a train-of-four stimulation count (TOF = 0). The patients were randomly allocated to one of the two groups using sequentially numbered sealed opaque envelopes naming the airway device to be evaluated first. The insertions were

6 performed by a single user (SG) who had an experience of more than 1000 insertions of any type of SAD including more than 90 i-gel insertions and more than 200 LMA-U insertions. The i-gel was inserted in accordance with manufacturer s guidelines. Size selection of the i- gel depended on patient weight: size 3 was used for patients <50 kg, size 4 was used for those between 50 and 90 kg, and size 5 was used for those over 90 kg in weight. Similarly for the LMA-U we followed a weight based algorithm recommended by the manufacturers: size 3 was used for patients <50 kg, size 4 was used for those between 50 and 70 kg, and size 5 was used for those over 70 kg. The cuff of the LMA-U was inflated to two-thirds of the maximum recommended volume as this usually provides most effective seal. 9 Therefore size 3, 4 and 5 LMA-U were inflated with 13, 20 and 26 ml of air respectively. We did not measure cuff pressures using an aneroid cuff pressure gauge as this does not reflect our usual clinical practice. The time taken to insert the SAD was noted, this was defined as the time from picking up the SAD to first breath made by manual ventilation. Adequate placement of the SAD was assessed by gently squeezing the reservoir bag and observing the end-tidal carbon dioxide waveform and chest movements. If ventilation was inadequate, the following manipulations were allowed: gentle pushing or pulling of the device, chin lift, jaw thrust, head extension, or neck flexion. The number of attempts required for insertion was recorded. A failed attempt was defined as removal of the device from the mouth before re-insertion. Two attempts were allowed before device use was considered a failure. In the event of adequate ventilation not achieved using either SAD, the protocol was that the trachea of participant would be intubated using a standard tracheal tube and the participant would be excluded from the study. The number of manipulations and abandonment of the device after insertion and during maintenance of anaesthesia were recorded. TCI propofol with oxygen-enriched air

7 was used for maintenance of anaesthesia during data collection. Once a clear airway was established, the lungs were ventilated at three different pressures (15, 20, 25 cm H 2 O) using pressure-controlled ventilation (PCV) at a rate of 10 bpm and an inspiratory-to-expiratory ratio of 1:2 with no positive end expiratory pressure. Inspired and expired tidal volumes were recorded. Measurements were taken over 10 breaths for each pressure setting. Gastric insufflation was assessed by auscultation over the patient s epigastric area. Airway leak tests were then performed. The fresh gas flow was adjusted to 3 litre.min -1 and the adjustable pressure limiting (APL) valve of the circle system was completely closed. Airway pressures were not allowed to exceed 40 cm H 2 O. Test 1 (auscultation) measuring the minimal airway pressure at which an audible gas leak occurred using a stethoscope placed just lateral to thyroid cartilage. Test 2 (manometer stability) involving observation of the aneroid manometer dial as the pressure from the breathing system increased and noting the airway pressure at which the dial reached stability (i.e. the airway pressure at which the leak was in equilibrium with fresh gas flow). Following completion of the above tests the first SAD was removed and any visible blood on the SAD was noted. The second SAD was then inserted after rechecking neuromuscular blockade and the previous measurements were repeated. The difference between inspired tidal volume (ITV) and expired tidal volume (ETV) was used to calculate leak volume (LV), i.e. LV=ITV ETV. The leak fraction was defined as leak volume divided by ITV (i.e. leak fraction=lv/itv). The primary outcome for the study was the airway leak pressure of the two SADs. For sample size calculation, we consider a 5 cm H 2 O to be a clinically significant difference. 10 A

8 previous study with the LMA-U showed the average airway leak pressure to be 19 cm H 2 O with a standard deviation of 5 cm H 2 O. 11 A two sample study design, using a t-test for comparison of group means, would therefore require a total of 34 patients for 80% power at a significance level of 5% (nquery Advisor 4.0). Our study used a crossover design and should have greater power to detect discernable differences between the devices. However, there was no data available on the within-subject variability of the primary endpoint, so it was unclear whether within-patient differences would follow a normal distribution, as would be assumed in a paired t-test. We therefore decided to recruit 40 patients to allow for the imprecision in the power calculation and to allow for some loss of patients from the study. Patients were randomised to one of the two possible orderings of the devices in equal proportion, in random permuted blocks of 4 and 6. Airway leak pressures, insertion times, leak volumes and leak fractions were not normally distributed. However the differences between airway leak pressures of the two SADs were normally distributed (Kolmogorov-Smirnov test). Therefore the former were analysed using the Wilcoxon sign-rank test and the later was analysed using a paired t-test. Fisher s exact test was used to assess whether the first time success rates, number of manipulations and trauma rates were different between the two devices. Statistical analysis was performed using MINITAB 15.1 Statistical Software (Minitab Inc., State College, USA).

9 Results. Forty patients were recruited to the study; one patient was excluded from analysis because of calibration error of spirometer. The mean (SD) age, weight, and BMI of the participants are shown in Table 1. Majority of participants underwent gynaecological surgery (22/39), followed by general surgery (15/39) and orthopaedic surgery (2/39). The results of the study are summarised in Table 2 The mean [SD] difference in the airway leak pressure between the two devices was 2.8 [8.0] cm H 2 O in favour of the i-gel (95% CI -0.32, 4.88 cm H 2 O; p=0.084). The median [IQR] difference in the insertion time between the two devices was 2.3 [0.2-4.4] seconds again in favour of the i-gel (95% CI 1.05, 3.40 s; p=0.007). The difference between leak volumes and leak fractions was not significant between the groups. There were 3 cases of difficult insertion in the i-gel group and one difficult insertion in the LMA-U group. On analysis using Fisher s exact test the incidence of difficult insertions between the groups was statistically not different (p = 0.358). Number of manipulations required to achieve a clear airway was same in both the groups (four in each group). An acceptable airway could be achieved for all the study patients with both the SADs. Airway leak pressure above 40 cm H 2 O was achieved for three patients in each group. None of the participants in our study tested positive for gastric insufflations by auscultation over epigastric area using either of SADs. There were no adverse events such as regurgitation or aspiration during the study.

10 Discussion Since its introduction to the UK market in January 2007, the i-gel has been widely used as a SAD during anaesthesia and cardiopulmonary resuscitation. Apart from a soft, non-inflatable cuff, which may make its insertion easy and less traumatic, it has several design features which make it a useful SAD. It has a gastric channel which may allow early recognition of regurgitation of gastric contents and passage of a drainage tube. It has an epiglottic ridge which is designed to rest on the base of tongue and may prevent upward and outward movement. It has a ridged flattened stem to aid insertion and may reduce risk of axial rotation. Most of these designed features have not been tested in humans. An observational study evaluating its performance found the i-gel as a promising SAD. 6 However, we were unable to identify any published trials comparing the performance of the i-gel with its likely competitors for use during controlled ventilation. LMA-U is a commonly used single use SAD which has been shown to have similar clinical performance to the reusable LMA classic. 12 Comparing the two SADs we found that the median insertion time for the i-gel (12.2 s) was significantly shorter than the LMA-U (15.2s). This difference although statistically significant may not be clinically important but is an indication of ease of insertion. It is quite likely that this time difference might be a reflection of the time need for the cuff inflation of

11 the LMA-U. Bamgbade et al in an evaluation study of 300 i-gel insertions reported that in 290 patients the i-gel could be inserted within 5 s, but they did not specify how they defined insertion time. 13 This is very different to others studies which show median insertion time for the i-gel and the LMA-U as 15 s and 24 s respectively. 6, 11 Shorter insertion times in both the groups in our study may be related to the experience of the user. High first time insertion rate, low failure rate and low incidence of mucosal trauma in our study may be because of the same reason. A recent study showed that the experience had no effect on insertion but that study was done on manikins and the conclusion may not apply to live subjects. 5 There was no statistical difference between the median airway leak pressure achieved with the i-gel (25 cm H 2 O) and the LMA-U (22 cm H 2 O). The values of airway leak pressure found in our study are similar to those in previous studies. The median airway leak pressure for the i-gel has been quoted as 24-28 cm H 2 O, 6,8 whereas the values for the LMA-U have been shown to be 18-25 cm H 2 O. 14-15 No significant differences in the airway leak pressures, leak volumes and leak fractions suggest that the efficacy of seal provided by both devices is equivalent. There was no evidence of gastric insufflation, regurgitation, or aspiration while using any of the SAD during our study. The incidence of regurgitation and aspiration with the use of the i- gel is not known. Three cases of regurgitation of which one of them had a confirmed aspiration have been reported. 16 In all these cases the gastric channel allowed early identification of the regurgitation. The incidence of clinically detectable gastric insufflations and regurgitation with the use of LMAs in general is 0-0.3% and 0.07% respectively. 17 The incidence of aspiration with LMAs in fasted patients is 0.012%. 17 As in our previous study, we used pressure-controlled mode instead of volume-controlled mode for controlled ventilation. 8 This is because the amount of leak volume is affected by the pressure generated between the airway device and the supraglottic tissues. Furthermore there

12 is evidence to suggest that PCV is more efficient and safer than volume-controlled ventilation for controlled ventilation with a SAD. 18 Similarly we did not assess the anatomical position of the device in relation to vocal cords with fibreoptic bronchoscope as it has been shown that there is no correlation between fibreoptic scores and airway leak pressures. 19-20 Our study has several limitations. Firstly, the data was collected by an unblinded observer so we cannot exclude an element of bias, although by the use of a crossover design we were able to limit the influence of interpatient variability during the comparison. Secondly, both the devices were inserted by a single experienced user and our results may not be applicable to inexperienced users. Finally, because of the crossover design, we were unable to determine which SAD has higher airway morbidity. This needs a larger non-crossover or an observational study. In summary, we were unable to demonstrate any difference in efficacy of seal and success rate of first-time insertion between the i-gel and the LMA-U. The insertion time for the i-gel was marginally shorter. We conclude that the i-gel provides a reasonable alternative to the LMA-U for controlled ventilation during anaesthesia.

13 Acknowledgements We would like to thank the Department of Anaesthesia, Royal Alexandra Hospital, Paisley, UK for supporting our research project.

14 Funding Only departmental funds were used for this study. No external funds were obtained.

15 References 1. i-gel User Guide. Wokingham, UK: Intersurgical Ltd, 2009: Edition 7. 2. Jackson KM, Cook TM. Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia 2007; 62: 388 93 3. Wharton NM, Gibbison B, Gabbott DA, Haslam GM, Muchatuta N, Cook TM. I-gel insertion by novices in manikins and patients. Anaesthesia 2008; 63: 991 5 4. Soar J. The I-gel supraglottic airway and resuscitation some initial thoughts. Resuscitation 2007; 74: 197 5. Gatward JJ, Thomas MJC, Nolan JP, Cook TM. Effect of chest compressions on the time taken to insert airway devices in a manikin. Br J Anaesth 2008; 100: 351 6 6. Gatward JJ, Cook TM, Seller C, et al. Evaluation of the size 4 i-gel trade mark airway in one hundred non-paralysed patients. Anaesthesia 2008; 63: 1124 30 7. Richez B, Saltel L, Banchereau F, Torrielli R, Cros AM. A new single use supraglottic airway device with a noninflatable cuff and an esophageal vent: an observational study of the i-gel. Anesth Analg 2008; 106: 1137 9 8. Uppal V, Fletcher G, Kinsella J. Comparison of the i-gel with the cuffed tracheal tube during pressure-controlled ventilation. Br J Anaesth 2009; 102: 264 8 9. Keller C, Pühringer F, Brimacombe JR. Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway. Br J Anaesth 1998; 81: 186-7.

16 10. Cook TM, Cranshaw J. Randomized crossover comparison of ProSeal Laryngeal Mask Airway with Laryngeal Tube Sonda during anaesthesia with controlled ventilation. Br J Anaesth 2005; 95: 261-6 11. Brimacombe J, von Goedecke A, Keller C, Brimacombe L, Brimacombe M. The laryngeal mask airway Unique versus the Soft Seal laryngeal mask: a randomized, crossover study in paralyzed, anesthetized patients. Anesth Analg 2004; 99: 1560-3 12. Brimacombe J, Keller C, Morris R, Mecklem D. A comparison of the disposable versus the reusable laryngeal mask airway in paralyzed adult patients. Anesth Analg 1998; 87: 921-4. 13. Bamgbade OA, Macnab WR, Khalaf WM. Evaluation of the i-gel airway in 300 patients. Eur J Anaesthesiol 2008; 25: 865-6. 14. Francksen H, Bein B, Cavus E et al. Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures. Eur J Anaesthesiol 2007; 24: 134-40 15. van Zundert A, Al-Shaikh B, Brimacombe J, Koster J, Koning D, Mortier EP. Comparison of three disposable extraglottic airway devices in spontaneously breathing adults: the LMA-Unique, the Soft Seal laryngeal mask, and the Cobra perilaryngeal airway. Anesthesiology 2006; 104: 1165-9 16. Gibbison B, Cook TM, Seller C. Case series: Protection from aspiration and failure of protection from aspiration with the i-gel airway. Br J Anaesth 2008; 100: 415-7 17. Brimacombe J. Laryngeal Mask Anesthesia. Principles and Practice, 2nd edn. London, UK: WB Saunders, 2004; 551 18. Bordes M, Semjen F, Degryse C, Bourgain JL, Cros AM. Pressure-controlled ventilation is superior to volume-controlled ventilation with a laryngeal mask airway in children. Acta Anaesthesiol Scand 2007; 51: 82-5.

17 19. Brimacombe JR. Positive pressure ventilation with the size 5 laryngeal mask. J Clin Anesth 1997; 9: 113-7. 20. Inagawa G, Okuda K, Miwa T, Hiroki K. Higher airway seal does not imply adequate positioning of laryngeal mask airways in paediatric patients. Paediatr Anaesth 2002; 12: 322-6.

18 Table 1 Patient characteristics. Values given as mean (SD) or absolute numbers Parameters n = 39 Sex; Males: Females Age; (years) Weight; (Kg) Body Mass Index; kg m -2 2:37 47.8 (12.2) 70.3 (11.9) 26.3 (4.1)

19 Table 2 Values are expressed as median (IQR) or actual number (n=39). * p = 0.007 i-gel LMA Unique Ease of insertion Insertion times; s Insertion attempts; First/ Second Failed insertions 12.2 (9.7-14.3) 38/ 1 0 15.2 (13.2-17.3)* 39/ 0 0 Efficacy of seal Airway leak pressure; cm H 2 O (Manometer method) Airway leak pressure; cm H 2 O (Auscultation method) 25.0 (22.0-30.0) 25.0 (22.0-30.0) 22.0 (20.0-28.0) 22.0 (20.0-28.0) Leak Volume; ml 15 cm H 2 O PCV 20 cm H 2 O PCV 25 cm H 2 O PCV Leak Fraction 15 cm H 2 O PCV 20 cm H 2 O PCV 25 cm H 2 O PCV 30 (20.0-61.0) 34 (21.0-126.0) 43 (23.0-178.0) 0.07 (0.03-0.15) 0.04 (0.03-0.13) 0.04 (0.02-0.16) 21 (13.0-36.0) 28 (20.0-50.0) 48 (23.0-165.0) 0.04 (0.02-0.09) 0.04 (0.02-0.08) 0.05 (0.02-0.17) Mucosal trauma Visible blood (first device) 1 0

20