Australian Dental Journal

Similar documents
In-Silico approach on Offset placement of implant-supported bridges placed in bone of different density in Orthodontics.

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

Evaluation of Stress Distribution in Bone of Different Densities Using Different Implant Designs: A Three-Dimensional Finite Element Analysis

Comparative study of single-thread, double-thread, and triple-thread dental implant: a three-dimensional finite element analysis

Effects of Mesiodistal Inclination of Implants on Stress Distribution in Implant-Supported Fixed Prostheses

Tilted or Parallel Implant Placement in the Completely Edentulous Mandible? A Three-Dimensional Finite Element Analysis

Rehabilitation of a Patient with Completely Edentulous Maxillary Arch using All on 4 Concept of Implantation

CHAPTER. 1. Uncontrolled systemic disease 2. Retrognathic jaw relationship

Three-dimensional finite element analysis of the application of attachment for obturator framework in unilateral maxillary defect

Comparative study of 12 thread shapes of dental implant designs: a three-dimensional finite element analysis

Saudi Journal of Oral and Dental Research. DOI: /sjodr. ISSN (Print) Dubai, United Arab Emirates Website:

INTRODUCTION. Graduate student, Department of Prosthodontics and Dental Research Institute, Seoul National University 2

1- Implant-supported vs. implant retained distal extension mandibular partial overdentures and residual ridge resorption. Abstract Purpose: This

ABSTRACT INTRODUCTION

Mechanical and technical risks in implant therapy.

Occlusal Principles and Considerations for Implants: An Overview

PALATAL POSITIONING OF IMPLANTS IN SEVERELY RESORBED POSTERIOR MAXILLAE F. Atamni, M.Atamni, M.Atamna, Private Practice Tel-aviv Israel

Journal of Dental Research, Dental Clinics, Dental Prospects. Original Article

Components Of Implant Protective Occlusion A Review

Objective: The occlusal patterns are key requirements for the clinical success of oral

Young-Jin Park, DDS,* and Sung-Am Cho, DDS, MS, PhD

Placement of Posterior Mandibular and Maxillary Implants in Patients with Severe Bone Deficiency: A Clinical Report of Procedure

Bicortically Stabilized Implant Load Transfer

Fixed full-arch implant-supported acrylic resin prostheses

BIOMECHANICS AND OVERDENTURES

Fixed Partial Dentures /FPDs/, Implant Supported. in implant prosthodontics

Stress in the Mandible with Splinted Dental Implants caused by Limited Flexure on Mouth Opening: An in vitro Study

The restoration of partially and completely

An Innovative Technique to select Angled. Abutment using Inclination Gauge ORIGINAL ARTICLE ABSTRACT MATERIALS AND METHODS INTRODUCTION

A Clinical Study of Edentulous Patients Rehabilitated According to the All on Four Immediate Function Protocol

INFLUENCE OF CANTILEVER ON STRESS DISTRIBUITION IN BONE AROUND DENTAL IMPLANTS: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

Dental Research Journal

Effect of Screw Profile on Stress Distribution Pattern of Dental Implants by FEA

Effect of alveolar bone support on zygomatic implants in an extra-sinus position an FEA study

Samantha W. Chou, D.M.D N. Southport Ave. Chicago, Illinois Phone: Fax:

MECHANISM OF LOAD TRANSFER ALONG THE BONE- DENTAL IMPLANT INTERFACE

Frequency and Type of Prosthetic Complications Associated with Interim, Immediately Loaded Full-Arch Prostheses: A 2-Year Retrospective Chart Review

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

EVALUATION OF STRESS DISTRIBUTION AND MICROMOTION OF DENTAL IMPLANT: IN VIVO CASE STUDY

Many patients with atrophic edentulous maxillae

The fundamental biomechanics of oral implants. Dr. Szűcs Attila

Benefits of CBCT in Implant Planning

The Brånemark osseointegration method, using titanium dental implants (fixtures)

Recently, promising results have been observed when

Osseointegrated implant-supported

Since the introduction of the Branemark

MANAGEMENT OF ATROPHIC ANTERIOR MAXILLA USING RIDGE SPLIT TECHNIQUE, IMMEDIATE IMPLANTATION AND TEMPORIZATION

High Crown to Implant Ratio as Stress Factor in Short Implants Therapy

Dental Implant Treatment Planning and Restorative Considerations

Mechanical and technical risks in implant therapy.

Tilted Implants for the Rehabilitation of Edentulous Jaws: A Systematic Reviewcid_

Research Article Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

Restoration of Congenitally Missing Lateral Incisors with Single Stage Implants: An Interdisciplinary Approach

Peri-Implant Stress Analysis of Immediate Loading and Progressive Loading Implants in Different /jp-journals

A mimic osseointegrated implant model for three-dimensional finite element analysis

Influence of Different Angulations of Force in Stress Distribution in Implant Retained Finger Prosthesis: A Finite Element Study

Indirect retainers. 1 i

Dental Implant Planning using Cone Beam CT imaging: a pictorial guide.


Graft-less solutions in implant dentistry: Part 1

Bone Reduction Surgical Guide for the Novum Implant Procedure: Technical Note

SHAPE OPTIMIZATION AND TOLERANCE ANALYSIS OF DENTAL IMPLANTS BY MEANS OF VIRTUAL MODELS

Patterns of stress and strain in complete-arch prostheses supported by four or six implants: A literature review of finite element analyses

RESTORATION OF A FULLY EDENTULOUS PATIENT UTILIZING SIMPLE TECHNIQUES FOR IMPRESSION AND FABRICATION OF A HYBRID BRIDGE

Finite Element Analysis of Dental Implant as Orthodontic Anchorage

Dental Implants: A Predictable Solution for Tooth Loss. Reena Talwar, DDS PhD FRCD(C) Oral & Maxillofacial Surgeon Associate Clinical Professor

The Use of Alpha-Bio Tec's Narrow NeO Implants with Cone Connection for Restoration of Limited Width Ridges

FINITE ELEMENT ANALYSIS OF PERIODONTAL STRESSES IN FIXED PROSTHODONTICS

Stress and Displacement Analysis of Dental Implant Threads Using Three-Dimensional Finite Element Analysis

Stress analysis of different configurations of 3 implants to support a fixed prosthesis in an edentulous jaw

Immediate implant placement in the Title central incisor region: a case repo. Journal Journal of prosthodontic research,

Lect. 14 Prosthodontics Dr. Osama

Three dimensional finite element analysis of immediate loading mini over denture implants with and without acrylonitrile O ring

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

Shrikar R. Desai, I. Karthikeyan, and Rika Singh. 1. Introduction

Arrangement of the artificial teeth:

م.م. طارق جاسم حممد REMOVABLE PARTIAL DENTURE INTRODUCTION

International Journal of Research and Review E-ISSN: ; P-ISSN:

Long-term success of osseointegrated implants

The majority of the early research concerning

Evaluation of Effect of Connector Designs in Implant Tooth-supported Fixed Partial Denture: A Two-dimensional Finite Element Analysis

JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH

Immediate fixed teeth a treatment concept for edentulous patients

Implant-based fixed rehabilitation of

Biomechanical effects of offset placement of dental implants in the edentulous posterior mandible

Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

STUDYING THE EFFECT OF THE PRELOAD INDUCED BY SCREW TIGHTENING ON STRESS DISTRIBUTION OF A DENTAL IMPLANT

Jaw relation registration in RPD

A risk assessment treatment planning protocol for the four implant immediately loaded maxilla: preliminary findings

CT Scan Technology. An Evolving Tool for Avoiding Complications and Achieving Predictable Implant Placement and Restoration SCOTT D.

Three Dimensional Finite Element Analysis to Detect Stress Distribution in Spiral Implants and Surrounding Bone

Areview of recent studies concerning molar. Single Molar Replacement with a Progressive Thread Design Implant System: A Retrospective Clinical Report

Sho Kayumi 1,2, Yoshiyuki Takayama 1*, Atsuro Yokoyama 2 and Nana Ueda 1

Journal of Dental Research, Dental Clinics, Dental Prospects. Original Article

Mandibular implant-supported hybrid prostheses

Rehabilitating a Compromised Site for Restoring Form, Function and Esthetics- A Case Report

Available online at ScienceDirect

It has been proposed that partially edentulous maxillectomy

International Journal of Engineering Research and General Science Volume 3, Issue 1, January-February, 2015 ISSN

Stress distribution in maxillary al Title according to finite element analysi. Nomoto, S; Matsunaga, S; Ide, Y; Ab Author(s) T; Saito, F; Sato, T

Transcription:

Australian Dental Journal The official journal of the Australian Dental Association SCIENTIFIC ARTICLE Australian Dental Journal 2012; 57: 440 445 doi: 10.1111/adj.12002 Load transfer in tilted implants with varying cantilever lengths in an all-on-four situation AO Malhotra,* TV Padmanabhan, K Mohamed, S Natarajan, U Elavia *Department of Prosthodontics, Uttaranchal Dental and Medical Research Institute, Dehradun, Uttarakhand, India. Department of Prosthodontics, Faculty of Dental Sciences, Sri Ramachandra University, Chennai, Tamil Nadu, India. ABSTRACT Background: The aim of this study was to evaluate if tilting of the distal implant at different angulations (30 and 40 ) with different cantilever lengths (4 mm and 12 mm) affects the stress and strain distribution in an all-on-four situation. Methods: A completely edentulous mandible was modelled with four tapered implants placed within the interforaminal region to receive an all acrylic fixed prosthesis. The two posterior implants were tilted at an angle of 30 and 40. The prosthesis cantilever was given two different variables of 4 mm and 12 mm. For all models, the equivalent von Mises stress and strain was analysed using three-dimensional finite element analysis. Results: Statistical significance (p < 0.05) was seen when a comparison was made for the stress developed on the implant and cortical bone between the 30 and 40 distally tilted posterior implants in both situations. No significance was seen in the trabecular bone and on the strain developed in these situations. Conclusions: The study shows that increasing the tilt of the distal implants does not increase the stress significantly. It also shows that the architecture of the mandible plays a major role during treatment planning of a completely edentulous patient. Keywords: All-on-four, cantilever, fixed prosthesis, immediate loading, tilted implants. Abbreviation: FEA = finite element analysis. (Accepted for publication 28 March 2012.) INTRODUCTION A major problem facing dentistry is that approximately 20% of our population is edentulous. An excessive loss of the residual alveolar ridge makes it difficult to provide a prosthesis that meets the needs of these dental patients. Studies have demonstrated a successful outcome with implant-supported, complete arch fixed restorations for the rehabilitation of the edentulous patient. 1 The results from a long term clinical study by Eliasson et al. 2 indicated that four implants may be sufficient in the edentulous mandible when properly placed anterior to the mental foramina area. As the placement of implants with significant load bearing capacity often may be restricted to the anterior portions of the arch, cantilevers distal to the most posterior implants are often required. The presence of a load bearing cantilever increases the forces distributed to the implants, possibly up to two or three times the applied load on a single implant, due to the bending moments. To reduce the loading of the terminal implant some have advocated placing short implants distal to the mental foramina and having the cantilever segments rest on the implants without being connected. 3 Another concept which has been put forward by various authors is tilting of the posterior implants to decrease the cantilever length. By inclining the posterior implants distally the prosthesis may have adequate support in the premolar and molar areas. In addition to broadening the prosthetic base, the tilting may also allow for improved cortical anchorage and primary stability, short cantilever length, large inter-implant distance as well as the use of longer implants. The all-on-four concept was developed to create a fast and cost-effective treatment for edentulous patients with a fixed restoration. 4,5 This involves the placement of four implants as support for a full arch prosthesis. The four implants, of which the two most posterior implants are tilted distally, are immediately loaded with a screwretained acrylic prosthesis. Tilting of the posterior implants allows the final prosthesis to hold as many as 12 teeth with only short cantilevers. 440 ª 2012 Australian Dental Association

Load transfer in an all-on-four situation The purpose of this study was to evaluate the stress and strain produced on the implant and in the surrounding bone while using the standardized concept of all-on-four for an immediately loaded implant supported fixed full arch prosthesis using threedimensional finite element analysis (3-D FEA). MATERIALS AND METHODS A 3-D finite element model of a completely edentulous mandible, with four tapered implants, placed within the interforamina region to receive an all acrylic fixed full arch prosthesis was used in this study (Fig. 1 and 2). Computerized tomography of the mandible was used to obtain the finite element model of the mandibular bone. The 3-D tetrahedral structural solid finite elements using Pro Engineer Wildfire 2.0 software was used to model the bone, implant, abutment and the occlusal surface material. All materials used in the models were considered to be isotropic, homogenous and linearly elastic. Material properties of the materials used in the model are presented in Table 1. As there are no universally accepted properties of the biologic materials available in the literature, it was therefore decided to accept median values of those reported in the literature. Bone The bone was modelled with a height of 17 mm, width minimum of 8 mm and interforamina distance of 46 mm. The cortical bone was modelled at the top and bottom as 2 and 3 mm thick layers, respectively. The trabecular bone was modelled as a 12 mm thick layer between the two cortical layers. Woven bone was also modelled around the implant with a width of 1 mm in the area adjacent to the implant to depict an immediate loading situation. 40, while the two anterior implants were placed as far away from each other as possible, allowing a safe distance of 5 mm from the posterior implants, at an angle parallel to the long axis of the bone. A 4.3 mm straight and angulated abutment was used for anterior and posterior implants, respectively. The bone-toimplant contact given in this study was 65% to simulate an immediate loading situation. Prosthesis As cited by Ellakwa et al., 6 a minimum overall thickness of 1.5 mm is recommended to resist fracture. A fixed bridge with a cantilever on both ends was depicted in this study as a homogenous block of acrylic resin of 2 mm thickness. The cantilever was given two different variables (4 mm and 12 mm). Load A 100 N load was applied to the anterior implant which was placed in the canine region. A 250 N load was applied to the posterior distally tilted implant and the end of the cantilever to depict forces on the premolars and molars, respectively. Both axial and oblique forces were applied. The bilateral axial forces depicted a clenching situation while the unilateral forces depicted masticatory forces (Fig. 3 and 4). The oblique force was applied unilaterally at an angle of 30 to the long axis (Fig. 5). Comparative groups The comparative groups were: Group 1 30 angulated distal implant with 4 mm cantilever; Group 2 30 angulated distal implant with 12 mm cantilever; Group 3 40 angulated distal implant with 4 mm cantilever; and Group 4 40 angulated distal implant Implants A solid 4.3 mm tapered 15 mm long implant was selected for this study. The two posterior implants were placed 5 mm anterior to the mental foramen. The two posterior implants were tilted at an angle of 30 and Table 1. Material properties of materials used in the model Material Elastic modulus (GPa) Poisson s ratio Cortical bone 13.0 0.3 Trabecular bone 5.5 0.3 Woven bone 3.0 0.3 Titanium implant and abutment 102.0 0.35 Acrylic resin (prosthesis) 2.7 0.35 Fig. 1 Model showing all-on-four situation (30 angulation of the distal implants). ª 2012 Australian Dental Association 441

AO Malhotra et al. Fig. 2 Model showing all-on-four situation (40 angulation of the distal implants). Fig. 5 Oblique force applied at 30. with 12 mm cantilever. The loads were simultaneously applied on the canine (anterior implant), the distal implant and the end of the cantilever (molar) region in all four groups. Meshed models A FEA of the models was carried out using ANSYS Workbench 11 software (ANSYS Inc, Canonsburg, USA). The ProE models were imported to the ANSYS Workbench 11 software and the models were meshed (Fig. 6). Fig. 3 Bilateral loading. RESULTS An independent student t-test analysis was performed. The results did not show any statistical significance (p > 0.05) between 4 mm and 12 mm cantilever for both 30 and 40 distally tilted posterior implants and also between the 30 and 40 distally tilted posterior implants under all three loading conditions for both stress and strain. But statistical significance (p < 0.005) was seen when a comparison was made for the stress developed on the implant and cortical bone between the 30 and 40 distally tilted posterior implants in both situations (4 mm and 12 mm cantilever). No significance was seen in the trabecular bone and on the strain developed in these situations. Fig. 4 Unilateral loading. DISCUSSION The research hypothesis that tilting of splinted implants does not increase the bone stress, and that shortening the prosthesis cantilever length by implant tilting reduces the stress, is supported by this 3-D FEA. Another study conducted by Zampelis et al. 7 came to 442 ª 2012 Australian Dental Association

Load transfer in an all-on-four situation Fig. 6 Meshed model. Fig. 7 Comparison of stresses between 30 and 40 distally tilted distal implant situations. a similar conclusion. The results in our study showed that during oblique loading, stresses were higher than during axial loading in all situations, except where the distal implants are tilted distally by 40 and have a 12 mm cantilever posterior to it. The oblique load produces a bending moment which has the greatest potential to induce a high gradient of stress in the bone surrounding the implant. Also, the rotation induced by buccolingual and mesiodistal loads was responsible for the higher values of the maximum stress under these loads. This was also seen by Skalak as cited by Barbier and Schepers, 8 Borchers and Reichart, 9 and Stegaroiu et al. 10 Thus, in light of the high stress calculated for buccolingual forces, when planning and fabricating a superstructure it is important to create an occlusal shape that minimizes lateral force components. The same principle should be considered during occlusal adjustments. The highest von Mises stress and strain was seen near the distal implants supporting the distal cantilevers. The maximum stress and strain in the implant was found at the implant abutment interface. The stress was seen higher on the loading side. In bilateral loading the stress and strain was higher on the right side of the mandible than the left side (though the difference was minimum) in all situations except for the 40 angulated distal implant with 12 mm cantilever situation where it was seen higher on the left side. This may be due to the asymmetry of the model. In the cortical bone maximum stress and strain was found at the cervical aspect, near the implant neck and in the trabecular bone the maximum stresses were seen apical for axial loadings and cervically for unilateral oblique loadings. Similar findings have been reported by Borchers and Reichart, 9 Sevimay et al., 11 Jeong et al. 12 and Tashkandi et al. 13 The results from our study also showed that stresses are seen distal or mesial on axial loading (both bilateral and unilateral), and buccal or lingual on oblique unilateral loading. High stresses around the distal half of the distal implant, which was found under axial loads, resulted from both the rotation in the vertical plane and the load applied to that implant. Under buccolingual loads, the deformations that occurred as a combined effect of the rotations in the transversal and horizontal planes yielded increased stress around the distal implant and lower stress around the mesial implant. Another reason for stresses being distributed to the buccal or lingual side during oblique loading may be due to thinner buccal and lingual cortical plates. This has also been reported by Sevimay et al., 11 Geng et al. 14 and Stegaroiu et al. 10 Our results showed that increasing the tilt of the implants does not significantly increase stress and strain when the comparison was made between 30 and 40 situations in various loading situations. This is supported by Zampelis et al., 7 Krekmanov et al., 15 Aparicio et al., 16 Kronstrom 17 and Malo et al. 4,5,18 Studies by Zampelis et al. 7 showed the stress at the most coronal bone-to-implant contact was identical irrespective of the angle of the tilt, demonstrating that tilting of splinted implants does not result in increased stress. The graphical interpretation of their results also shows that the sequential increase in the angle of tilt does not proportionately result in increase in stress. The stress for 30 tilt was higher than stress for 0, 10, 20 and 45. A similar result was also seen in our study. No significant difference was seen on increasing the cantilever length from 4 mm to 12 mm. Though many studies have shown that stress increases with increase in cantilever length; a 3-D FEA model analysis was done by van Zyl et al. 19 for stress analysis of mandibular cantilever prosthesis. They reported that an optimal area of cantilever loading exists up to a cantilever ª 2012 Australian Dental Association 443

AO Malhotra et al. length of 15 mm where low patterns of von Mises stress develop. Extension beyond 15 mm could lead to greater stress in the lingual and buccal cortical plates, which could jeopardize the integrity of the implant. This may explain why there was no significant difference in our study between the two cantilever extensions of 4 mm and 12 mm as they lie within this optimal range. When the comparison was made between the two groups for implant, cortical bone and trabecular bone individually, a significant difference was seen between the two groups for stress. In implants the stress in 30 tilted distal implants was significantly higher (p < 0.05) than 40 while in cortical bone the stress was significantly higher in 30 than 40 angulated distal implants. This could be because increasing the tilt of the implant results in more acute angle at the distal surface of the implant, which in turn results in increased stress. The results from our study also revealed that the strain produced in different situations is within the normal physiologic zone except for strain in cortical bone on bilateral loading. This strain lies in the mild overload zone. When strain conditions to the interfacial bone are in mild overload zone, an increased bone modelling response occurs, which results in a reactive woven bone formation that is less mineralized and weaker. Greater stresses may cause the interfacial strain to reach the pathologic overload zone and may cause microfracture of the bone, fibrous tissue formation, and or bone resorption. Although our study was conducted in such a way as to simulate the clinical scenario as close as possible, some limitations do exist when not directly dealing with a clinical case. As stated by Lewis and Klineberg, while laboratory and FEA studies provide insight into the way a system works, the results do not necessarily correlate with clinical performance and need to be interpreted with caution. 20 CONCLUSIONS Within the limitations of this study, the findings provide evidence that increasing the tilt of the distal implant does not significantly increase the stress. The study also shows that the architecture of the mandible plays a major role during treatment planning of a completely edentulous patient, especially when considering a crossarch splinted restoration. This is because the stress and strain on the thinner segment of the mandible will take up more load, resulting in increased bone resorption on that side. Thus, our study confirms the results seen in clinical situations which report a fairly good success rate. Within the limitations of this study, we conclude that all-on-four is a mechanically viable concept and leaves room for further research on other variables that could influence the biomechanical outcome. REFERENCES 1. Adell R, Eriksson B, Lekholm U, Brånemark PI, Jemt T. Long term follow up study of osseointegrated implants in treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5:347 359. 2. Eliasson A, Palmqvist S, Svenson B, Sondell K. Five-year results with fixed complete-arch mandibular prostheses supported by 4 implants. Int J Oral Maxillofac Implants 2000;15: 505 510. 3. Schnitman PA, Wohrle PS, Rubenstein JE, Silva JD, Want NH. Ten-year results for Brånemark implants loaded with fixed prostheses at fixture placement. Int J Oral Maxillofac Implants 1997;12:495 503. 4. Malo P, Rangert B, Nobre M. All-on-four immediate-function concept with Brånemark system implants for completely edentulous mandibles: a retrospective clinical study. Clin Implant Dent Relat Res 2003;5:2 9. 5. Malo P, Rangert B, Nobre M. All-on-four immediate-function concept with Brånemark system implants for completely edentulous maxillae: a 1 year retrospective clinical study. Clin Implant Dent Relat Res 2005;7:88 94. 6. Ellakwa A, Raj T, Deeb S, Ronaghi G, Martin FE, Klineberg I. Influence of implant abutment angulations on the fracture resistance of overlaying CAM-milled zirconia single crowns. Aust Dent J 2011;56:132 140. 7. Zampelis A, Rangert B, Heijl L. Tilting of splinted implants for improved prosthodontic support: a two-dimensional finite element analysis. J Prosthet Dent 2007;97:35 43. 8. Barbier L, Schepers E. Adaptive bone remodeling around oral implants under axial and non axial loading conditions in the dog mandible. Int J Oral Maxillofac Implants 1997;12:215 223. 9. Borchers L, Reichart P. Three dimensional stress distribution around a dental implant at different stages of interface development. J Dent Res 1983;62:155 159. 10. Stegaroiu R, Sato T, Kusakari H, Miyakawa O. Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. Int J Oral Maxillofac Implants 1998;13:82 90. 11. Sevimay M, Turhan F, Kilicarslan MA, Eskitascioglu G. Threedimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown. J Prosthet Dent 2005;93:227 234. 12. Jeong CM, Caputo AA, Wylie RS, Son SC, Jeon YC. Bicortically stabilized implant load transfer. Int J Oral Maxillofac Implants 2003;18:59 65. 13. Tashkandi EA, Lang BR, Edge MJ. Analysis of strain at selected bone sites of a cantilevered implant-supported prosthesis. J Prosthet Dent 1996;76:158 164. 14. Geng JP, Tan KBC, Liu GR. Application of finite element analysis in implant dentistry: a review of literature. J Prosthet Dent 2001;85:585 598. 15. Krekmanov L, Kahn M, Rangert B, Lindström H. Tilting of posterior mandibular and maxillary implants for improved prosthesis support. Int J Oral Maxillofac Implants 2000; 15:405 414. 16. Aparicio C, Perales P, Rangert B. Tilted implants as an alternative to maxillary sinus grafting: a clinical, radiologic and periotest study. Clin Implant Dent Relat Res 2001;3:39 49. 17. Kronström M. Prosthodontics and the general dentist. A study of practice profiles and prosthodontic decision making in Sweden. Swed Dent J Suppl 1999;137:1 62. 444 ª 2012 Australian Dental Association

Load transfer in an all-on-four situation 18. Malo P, Nobre M, Lopes A. The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow up period of thirteen months. J Prosthet Dent 2007;97:26 34. 19. van Zyl PP, Grundling NL, Jooste CH, Terblanche E. Threedimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses. Int J Oral Maxillofac Implants 1995;10:51 57. 20. Lewis MB, Klineberg I. Prosthodontic considerations designed to optimize outcomes for single-tooth implants. A review of the literature. Aust Dent J 2011;56:181 192. Address for correspondence: Dr Upali Elavia Room 8, Department of Prosthodontics Faculty of Dental Sciences Sri Ramachandra University Porur Chennai Tamil Nadu 600116 India Email: upali.elavia@gmail.com ª 2012 Australian Dental Association 445