The Do s and Don ts of Pressure Transducers

Similar documents
4-20 ma Pressure Transducer

Fundamentals of Pressure Transducers

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

Preparation and Installation of the SANITRX / SANITRX LP (IS) Rupture Disc for Use With Industry Standard Ferrules

PHM-100 PORTABLE HANDHELD TRANSDUCER INDICATOR OPERATORS MANUAL. Transducer Techniques R

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

DC Unbalance Tolerance Testing in PSE s

Technical Data Sheet SONOFLOW CO.55 V1.0

T E C H N I C A L B U L L E T I N

Technical support: +49 (0)7223 /

Installation Instructions

Improving Headphone Fit Using Design Of Cable

Fittings & Accessories

EI2311 BIOMEDICAL INSTRUMENTATION

Side Channel R ing Blower

DEFORMATION TRANSDUCER CALIBRATOR OPERATION

Sep2018 Rev B1

E200 ORT - Optical Rotary Torque Transducer. Contents

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

INSTRUCTION MANUAL (MAN-70254)

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

MIE Medical Research Ltd Digital Analyser - Myometer Instruction Manual

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

Electromyography II Laboratory (Hand Dynamometer Transducer)

E SERIES. Contents CALIBRATION PROCEDURE. Version 2.0

IPC-6018A. Microwave End Product Board Inspection and Test IPC-6018A. A standard developed by IPC. Supersedes IPC-6018 January 1998

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION MARCH

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

TEKNOCRAFT INC. Proportional Valves. Mini Valves. Outlet Balanced Valves. Standard Valves. Your Proportional Valve Specialists

Universal Calibration Device for Pressure Transducer Calibration

MEDIUM-FLOW PNEUMOTACH TRANSDUCER

CITY OF WAUPACA, WISCONSIN WATER DEPARTMENT WATER SERVICE LATERAL THAWING RULES AND PROCEDURES (prepared February 24, 2015)

With extended functionality the sensors are also applicable for the detection of air bubbles.

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

Qualification and Performance Specification for Rigid Printed Boards

Alternative Design 1

Tru-Fit 10k Fittings

System Multiplexer / Permissive Module

STUDY ON APPLICATION OF STRAIN MEASURING TECHNOLOGY IN BOARD LEVEL ASSEMBLY PROCESS

SURETEST Torque Calibration System

T2, T3, T4, T5, T6, T7, T12 & T15 Rotary Torque Transducers Operation Manual

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Technical Tip: How to Connect and Troubleshoot Transducer Feedback. Product(s): iqpump1000 and iqpump Micro Drives

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( The story so far

CABINA S40 USER MANUAL AUDIOMETRIC TEST BOOTH MU2 REV. 1.05

INTERNATIONAL STANDARD

SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass

Angular Measurements with BIOPAC Goniometers & Torsiometers

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan

Process lock Dalton. Use: Features: Door and hatches

WNK5 Series High Precision Pressure Transmitter

S51 Series. Thread Together, Maximum Flow with Minimum Spillage

Simrad SP90/SX90/SU90

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

SURETEST Torque Calibration System

E-Link Gateway Installation Instructions

HiFFUT A New Class of Transducer

USER MANUAL, VOL.2.0 T I S S U E P U L L E R T P

Accessing the "Far World": A New Age of Connectivity for Hearing Aids by George Lindley, PhD, AuD

Most of the Conductivity/Resistivity electrodes used with the 2850 can be installed into standard 3 /4 in. (NPT or ISO 7-R 3 /4) fittings.

Capacitive Sensors 17


ProVari Owner s Manual

Standards. Certification. Education & Training. Publishing. Conferences & Exhibits. Table of Contents. View Excerpt. Buy the Book

TECH 2 Dew Point Retrofit Kit

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

Direct Reading (Pocket) Dosimeter

3.5 mm Locking Attachment Plate

lntelligent VENDINGLtd

Compressor Accessories

Set-up Instructions. MANUFACTURED BY COMMUNICATIONS-APPLIED TECHNOLOGY CO., INC. RESTON, VA. CAGE CODE: 0EEY2

RST INSTRUMENTS LTD.

Sign Language Interpretation Using Pseudo Glove

GLAST Large Area Telescope:

The ADL Force 5 configured for knee testing

RUBBER WATERBLAST HOSES

High current plug-in connector

Kadi Sarva Vishvavidyalaya, Gandhinagar Bachelor of Engineering (Electrical Engineering Syllabus)

CSA Z32 TESTING GUIDELINE AND PROCEDURES

Introduction. Table of Contents

RLS /M MX SERIES

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

Variable Frequency Drives

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

Development and application of a hand force measurement system

Multipower. User Guide E S S E N T I A L S T R E N G T H

FlexiSafe MLCC Termination Device Performance

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port

Bio Mechanical Hoof Tester Operator s Manual

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry.

Mounting and Wiring VMA1200 Series Controllers

OPTICAL FIBER SPLICING. Courtesy from Significant Technologies Sdn Bhd

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Transcription:

The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed in terms of the transducer itself as well as the overall measuring system. This information is user-oriented and serves as a practical guide in the selection and application of strain gage pressure transducers. INTRODUCTION Over the years, bonded strain gage pressure transducers have provided a convenient, accurate and reliable means of measuring fluid pressure. The present day foil strain gage is far more sophisticated than its wire gage ancestor. Going from wire to foil in the early 1950 s brought about major improvements in overall transducer performance. The improvement has been ongoing and today s strain gage transducers are a far cry from the models built in the past. Significant advances have been made in many areas such as improved heat dissipation, better bonding techniques, superior adhesives, reduced creep and hysteresis effects and improved temperature compensation. The result is a transducer that is more accurate and reliable than other types. TRANSDUCER To better understand the do s and don ts of pressure transducers, it s worthwhile taking a brief look at how they work. The transducer is installed in the system by means of its pressure fitting, which can be either an internal or external threaded connection. The thread itself can be either a tapered pipe thread or a straight thread with an O ring or plug seal. Once installed, the pressure is applied to the transducer causing a force-summing element to convert the pressure into a physical displacement. The forcesumming element, which in most cases is a diaphragm, develops surface strains proportional to the pressure. Strain gage pressure transducers, by design, are rugged, accurate, and stable. They are capable of operating in severe shock and vibration environments as well as a wide variety of pressure media. They are offered with a variety of electrical and pressure connections and can be installed directly at the point of measurement. FOIL STRAIN GAGE In order to utilize the pressure to strain relationship, foil strain gages are bonded to the diaphragm and become the primary sensors. As such, they change resistance as a function of the diaphragm strain, which is, in turn, related to pressure.

The strain gages, usually four (4) in number, are wired in series to form a Wheatstone Bridge. The bridge concept is used since it s the simplest and most accurate method conceived for measuring small resistance changes. With voltage applied to two (2) opposite corners of the bridge, an electrical output signal is developed proportional to the applied pressure. The output signal level is in millivolts per applied volt and is collected at the remaining two (2) corners of the bridge. TRANSDUCER SIGNAL Because they can convert fluid pressure into an electrical signal, transducers are user friendly. The signal can be transmitted from the pressure site to remote locations and used for specific control, monitoring and measurement purposes. They interface with data loggers, data acquisition systems, computers and readout instruments. Strain gage transducers are available in both low and high level outputs. The low level output for foil gage transducers is a 3 mv/v or 30 millivolts at 10 VDC input. High-level outputs are 5 VDC and 10 VDC at an input voltage of 24 to 32 VDC and 4-20 ma at a 12 to 36 VDC input. For the digital world, the analogto-digital (A/D) converter is used to translate the analog signals into digital bits. Proper application with knowledge of certain limitations, will assure long transducer life and high integrity performance. CONSIDERATIONS The factors that have to be considered in the care and feeding of transducers can be placed into the following categories: 1) Pressure Range Transducers are designed to provide a specific electrical output for a given pressure range. This relationship is always given in the manufacturer s product specifications. In general, transducers are available in a number of discreet pressure ranges from 0-5 PSI to 0-100,000 PSI rated pressure. Many suppliers can provide some or all of the ranges in high level or low level electrical outputs. In choosing a transducer, select a pressure range such that operating pressure is approximately 80% of full scale. Also, select an electrical output level that is compatible with your system needs. If transducer cable runs exceed 100 feet, consider a high level unit if the environment is intolerant of low-level signals. Although we are talking about a rugged device, requiring virtually no maintenance, transducers are subject to misapplication and damage.

2) Pressure/Electrical Connections All transducers require two connections, a mechanical pressure connection and an electrical connection. Since there are no industry standards established, you have to check the transducer manufacturer s data to determine the configuration he offers with his products. Pressure fittings are normally made of stainless steel and designed to be leak-free within the operating parameters of the transducer. The electrical termination on the transducer is usually a multi-pin connector or a cable. The connector usually has 6 pins for compatibility with 6 conductor cable assemblies that go from the transducer to the instrumentation. Make certain that the transducer you select meets not only performance specifications, but properly mates with your electrical and mechanical connections. There is nothing more frustrating than purchasing a transducer and finding out that is doesn t fit into your standard pressure port. The same is true of your electrical connection, which has an added dimension. Not only must the connection be compatible with your system mechanically, it must also have the same wiring code for electrical pin-to-pin compatibility. Pay attention to both the pressure and electrical interface. 3) Handling and Installation A pressure transducer is a rugged device, built in to withstand the rigors of the industrial world. It performs its task extremely well and requires very little attention once installed and operating. However, it is a precision measuring device and does require a certain amount of care to maintain its integrity. During installation, take care not to damage the electrical connector. This is probably the most vulnerable part of the transducer. Denting the connector shell or bending a pin could put the unit out of commission. Many high level transducers have zero and span adjustment access holes located on the transducer s connector plate. Make certain that these units are installed so the adjustments can be reached with a screwdriver. The pressure fitting on the transducer is designed to properly secure the unit in place. Do tighten the transducer well to avoid the possibility of leaks. Proper tightening will not harm the transducer s performance and will assure leak-proof operation.

4) Media Compatibility Because transducers are called upon to operate in a variety of pressure media, they must have some built-in protection against hostile fluids. This is accomplished by making the pressure-sensing end out of hardened stainless steel. In most cases, the material is 17-4 PH or 15-5 PH. To further enhance protection, the outer shell or cover is usually made from 303 or 304 stainless steel. Corrosion of the transducer s diaphragm can change the output sensitivity and affect it structural strength. In almost all system applications, the media is never a problem and should not be of concern. However, if there is any doubt as to which material is best for a given situation, do consult the manufacturer. 5) System To insure accuracy and reliability, attention has to be paid to the entire system. The transducer is one component in a system that typically includes cabling, signal conditioning, amplification and readout devices. The largest source of system error is the input wiring to the transducer. This error is due to noise generated by electrostatic coupling and inductive pickup (EMI/RFI). The former generates noise due to coupling of the electric fields surrounding signal wires. This is brought about by the capacitance between individual conductors and between the conductors and ground. Capacitive coupling is more of a problem in longer cables because capacitance between conductors increased with cable length. To eliminate these unwanted signals, use shielded cable and ground only on one end of the shield. Do not ground both ends, or it will become a signal conductor, capacitively coupled to the measured signal. Motors, power lines, transformers and similar sources generate electro-magnetic fields, which can be picked up inductively. These strong magnetic fields are a source of noise, which can induce signal errors. Using twisted pairs will effectively cancel the noise due to inductive pickup. In those cases where a low signal level cable is close to high voltage cables, the low level cable can be run in a metal conduit. The problems caused by grounds are probably the least understood and may well be the most troublesome of all sources of noise. To help minimize grounding problems, a signal circuit should be grounded in one (1) place only. The difference in potential between multiple

ground points can cause circulating currents and as a consequence generate noise. A high level of system isolation will keep ground effects to a minimum if all else fails. As a final note, all electrical interconnects between system components should be properly mated, clean and have the highest integrity. More problems are solved in the field by merely tightening a loose transducer connector. This should serve as a practical guide on selecting and using pressure transducers. Since it can t cover all of your questions, consult directly with the transducer supplier for his advice and help.