Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates

Similar documents
Clinical Study Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES

COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES

Treatment of unstable distal radius fractures with the volar locking plate

Surgical Management of Distal end Radius Fractures by Various Methods: A Prospective Study

Hardware-Related Complications After Dorsal Plating for Displaced Distal Radius Fractures

Case Report Bone Resection for Isolated Ulnar Head Fracture

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

Emile N. Brown, MD, and Scott D. Lifchez, MD

Incidence 643,000 per year United States 15% of all fractures, peak occurrence age 60 70, Classification - AO/OTA (Murray 2013)

Distal radius fractures raises considerable interest and

Case Report Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

Long-term Results of Dorsally Displaced Distal Radius Fractures Treated With the Pi-Plate: Is Hardware Removal Necessary?

Case Report Successful Closed Reduction of a Lateral Elbow Dislocation

Comparison between Distractor Application on Both Radial & Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY

A prospective study of surgical management of distal radius fracture in adult with plate fixation

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Case Report An Undescribed Monteggia Type 3 Equivalent Lesion: Lateral Dislocation of Radial Head with Both-Bone Forearm Fracture

Intra articular distal radius fractures and volar plate fixation: a prospective study

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Case Report Medial Radial Head Dislocation Associated with a Proximal Olecranon Fracture: A Bado Type V?

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

journal ORIGINAL RESEARCH

Factors Predicting Late Collapse of Distal Radius Fractures

JMSCR Vol 05 Issue 06 Page June 2017

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

FUNCTIONAL AND RADIOLOGICAL OUTCOMES AFTER VOLAR LOCKING PLATE FIXATION IN TYPE C DISTAL RADIUS FRACTURES A RETROSPECTIVE STUDY

Outcome following distally locked volar plating for distal radius fractures with metadiaphyseal involvement

Int J Clin Exp Med 2017;10(1): /ISSN: /IJCEM

Management of intra-articular fractures of distal end radius in adults

Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

Radiographic Evaluation and Classification of Distal Radius Fractures

Operative Indications

ORIGINAL ARTICLE. possible. Accurate assessment of standard radiographs is essential for appropriate 3. management. And includes true posterior- 4

Cover Page. The handle holds various files of this Leiden University dissertation.

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬

Case Report Pediatric Transepiphyseal Seperation and Dislocation of the Femoral Head

Functional Outcome in Distal Radius Fractures Treated with Locking Compression Plate

Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study

Comparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the Distal End Radius

Redisplacement of Distal Radius Fracture after Initial Closed Reduction: Analysis of Prognostic Factors

Injury, Int. J. Care Injured 42 (2011) Contents lists available at ScienceDirect. Injury. journal homepage:

Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate

Baris Beytullah Koc, 1 Martijn Schotanus, 1 Bob Jong, 2 and Pieter Tilman Introduction. 2. Case Presentation

Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture

Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

Distal radius fractures

Research Article The Effects of Dorsal Cortical Comminution on Radiographic Results following Percutaneous Pinning for Extra-Articular Colles Fracture

Fractures of distal end of Radius: A study on fracture reduction and stable fixation

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Carpal rows injuries!

5/9/2017. Distal Radius Fractures: What s New? What s New? Or Maybe New to you. Single Pak Sterile distal radius kits

Forearm Fracture Solutions. Product Overview

Primary internal fixation of fractures of both bones forearm by intramedullary nailing

Outcome of fracture distal radius treated with open reduction internal fixation with volar locking compression plate (A study of 50 cases)

Acomparison of percutaneous and pin-and-plaster techniques in distal radius fracture

Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures

University of Groningen. Fracture of the distal radius Oskam, Jacob

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Disclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant

Study of Evaluation of Lateral Surgical Approach for Diaphyseal Fractures of Distal 2/3rd of Radius at a Tertiary Care Teaching Centre

University of Groningen. Fracture of the distal radius Oskam, Jacob

Angle Stable Distal Radial Plate System WINSTA-R

Case Report Arthroscopic Bony Bankart Repair Using Double-Threaded Headless Screw: A Case Report

University of Groningen. Fracture of the distal radius Oskam, Jacob

D-RAD SMART PACK Plating System. A series of case studies

Case Report Multiple Giant Cell Tumors of Tendon Sheath Found within a Single Digit of a 9-Year-Old

UZZAMAN KS 1, AWAL KA 2, ALAM MK 3

Case Report Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy

Case Report Intra-Articular Osteotomy for Distal Humerus Malunion

Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report

Hand and wrist emergencies

The Utility of the Fluoroscopic Skyline View During Volar Locking Plate Fixation of Distal Radius Fractures

Distal radius fracture Golden standard and breaking news

Case Report A Case Report of Isolated Cuboid Nutcracker Fracture

Breakage of a volar locking plate after delayed union of a distal radius fracture

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

ORIGINAL ARTICLE FUNCTIONAL OUTCOME OF UNSTABLE DISTAL RADIUS FRACTURES - TREATED BY PERCUTANEOUS K-WIRE FIXATION

Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures.

Distal Radius Plate 2.4/2.7 dorsal and volar

Additional Ulno-Radial Pinning for Prevention of Metaphyseal Collapse in Distal Radius Fracture: A Comparative Study

Common Limb Fractures. Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009

Fractures of the distal end of the radius should be

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Instrument and Implant for wrist fracture

OUTCOME OF MANAGEMENT OF CLOSED PROXIMAL TIBIA FRACTURES IN TERTIARY HOSPITAL OF SURAT Karan Mehta 1, Prashanth G 2, Shiblee Siddiqui 3

ROLE OF LOCKING COMPRESSION PLATES IN THE TREATMENT OF FRACTURES DISTAL END OF RADIUS

Therapeutic Effects of Volar Anatomical Plates Versus Locking Plates for Volar Barton s Fractures

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Research Article Relationship between Pain and Medial Meniscal Extrusion in Knee Osteoarthritis

Degrees Of Volar Angulation In Distal Radius Fracture Effects Distal Radioulnar Joint Stability:a Biomechanical Study

A novel method of treating isolated unicondylar fracture of the head of the proximal phalanx: A case report

Transcription:

ISRN Orthopedics Volume 2013, Article ID 131757, 6 pages http://dx.doi.org/10.1155/2013/131757 Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates Paritosh Gogna, 1 Harpal Singh Selhi, 2 Rohit Singla, 1 Ashish Devgan, 1 Narender Kumar Magu, 1 Pankaj Mahindra, 2 and Mohammad Yamin 2 1 DepartmentofOrthopaedicsandRehabilitation,Pt.B.D.SharmaPostgraduateInstituteofMedicalSciences, 2/11-J Medical Enclave, PGIMS, Haryana, Rohtak 124001, India 2 Department of Orthopaedics, Dayanand Medical College and Hospital, Punjab, Ludhiana 141001, India Correspondence should be addressed to Paritosh Gogna; paritosh.gogna@gmail.com Received 12 March 2013; Accepted 14 April 2013 Academic Editors: D. H. Clements, C.-H. Lee, G. Papachristou, C.-H. Tsai, and B. K. Weiner Copyright 2013 Paritosh Gogna et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Background. Dorsally comminuted distal radius fractures are unstable fractures and represent a treatment challenge. The objective of this study was to evaluate the functional and radiological outcome of dorsally comminuted fractures of the distal radius fixed with a volar locking plate. Patients and Methods. Thirty-three consecutive patients with dorsally comminuted fractures of the distal end of the radius were treated by open reduction and internal fixation with AO 2.4 mm (n =19)/3.5 mm (n =14) volar locking distal radius plate (Synthes, Switzerland, marketed by Synthes India Pvt. Ltd.). There were 7 type A3, 8 type C2, and 18 type C3 fractures. The patients were followed up at 6 weeks, 3 months, 6 months, and 1 year postoperatively. Subjective assessment was done as per Disabilities Arm, Shoulder, and Hand (DASH) questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist; the radiological determinants were radial angle, radial length, volar angle, and ulnar variance. The final assessment was done as per Demerit point system of Saito. Results. There were 23 males and 10 females with an average age of 44.12 ± 18.63 years (18 61 years). Clinicoradiological consolidation of the fracture was observed in all cases at a mean of 9.6 weeks (range 7 12 weeks). The average final extension was 58.15 ± 7.83, flexion was 54.62 ± 11.23, supination was 84.23 ± 6.02, and pronation was 80.92 ± 5.54. Demerit point system of Saito yielded excellent results in 79% (n =26), good in 18% (n =6), and fair in 3% (n =1) patients. Three patients had loss of reduction but none of the patients had tendon irritation or ruptures, implant failure, or nonunion at the end of an one-year followup. Conclusion. Volar locking plate fixation for dorsally comminuted distal radius fractures results in good to excellent functional outcomes despite a high incidence of loss of reduction and fracture collapse. 1. Introduction With an incidence of about 17% of all fractures, the distal radial fracture is the most common fracture in the human skeleton [1]. Dorsally comminuted fractures are highly unstable,andclosedreductionresultsinunsatisfactoryoutcome [2].Therehasbeenaconsensusonopenreductionandinternal fixation of these fractures so as to restore the distal radius anatomy and regain early return to activity [3]. Dorsal approach allows direct articular visualization and placement of plate as a dorsal buttress; however, a high incidence of hardware-related problems has culminated in a recent trend towards volar plates [3, 4]. Volar locking plate provides stable fixed angle support that permits early active wrist rehabilitation, direct fracture reduction, and fewer soft tissue and tendon problems [3]. Recently performed studies have found it to be effective in treating dorsally comminuted distal radius fractures [4, 5]. The present study was done to evaluate the outcome of the unstable dorsally comminuted fractures of the distal end of the radius managed with a locked volar plate. 2. Patients and Method This prospective study is comprised of 33 consecutive patients with dorsally comminuted fractures of the distal radius. Exclusion criteria were skeletally immature patients, open fractures, pathological fracture, and previously operated or nonfunctional wrist. Fractures were classified as per AO/OTA classification (Table 1). Dorsallydisplaced fracturefragments

2 ISRN Orthopedics Mean age at presentation Sex Mode of injury Type of fracture RTA: road traffic accident. Table 1: Clinical profile of patients. 44.12 ± 18.63 years (range 18 61 years) Male 23 Female 10 RTA 26 Fall 7 A3 7 C2 8 C3 18 were indirectly reduced using a combination of direct pressure and ligamentotaxis (the intact dorsal capsule aids in falling back of the boney fragments). Fractures were fixed usingvolarapproachofhenrywith2.4mm(n=19)/3.5 mm (n =14) volar locking distal radius plate (Synthes, Switzerland, marketed by Synthes India Pvt.) under image intensifier. The stability of fixation was checked by moving the wrist joint through the complete range of motion. Postoperatively Plaster of Paris backslab was given to give rest to the operated part. Active finger movements were encouraged immediately after operation along with elevation. Supervised physiotherapy in the form of active wrist movements and hand functions pinch and grasp was begun at 2 weeks after suture removal. Patients were reviewed clinicalradiologically at 6 weeks 3 months, 6 months and 1 year postoperatively. Subjective assessment was done as per DASH questionnaire. Functional evaluation was done by measuring range of motion around the wrist, whereby extension, flexion, supination, and pronation were measured with the help of goniometer. Grip strength was measured in Kg with the help of dynamometer and compared with the contralateral side. Paired Student s t-test was applied to compare the functional parameters, namely, extension, flexion, supination, pronation, and grip strength at 6 weeks and at 1 year. The radiological determinants, that is, radial angle, radial height, volar angle, and ulnar variance were measured with the help of goniometer on standard anterioposterior and lateral radiographs of the wrist. Satisfactory reduction was defined as <10 of dorsal tilt, <2mmofradialshorteningand<1mm of articular incongruity [4, 6, 7]. Paired Student s t-test was applied to compare the radiological parameters, namely, radial angle, radial length, volar angle, and ulnar variance measuredintheimmediatepostoperativeperiodwiththose at 1 year. The final outcome was evaluated on the basis of functional and radiological demerit point system of Saito [8]and complications if any were noted. 3. Results There were 21 males and 5 females with an average age of 44.12 ± 18.63 years(18 81years).Themajorityofcaseswere due to road traffic accident in younger age group, whereas direct fall on outstretched hand was a common mode of injury in the older age group. Clinicoradiological consolidation of the fracture was observed in all cases at an average of 9.6 weeks (7 12 weeks). Table 2: Radiological evaluation. Postoperatively At 1 year Radial inclination 23.42 ± 3.65 23.98 ± 4.21 Radial length 12.51 ± 2.77 mm 12.63 ± 2.34 mm Volar angle 5.86 ± 6.74 5.54 ± 7.52 Ulnar variance 0.77 ± 0.88 mm 0.55 ± 1.1mm mm: millimeters. We were able to attain adequate reduction in all patients (Figures 1 and 2). Immediate postoperative radiological parameters were compared with those at 1 year using Student s paired t-test, which revealed the difference to be insignificant (P > 0.05) for all four parameters (Table 2). On comparing results from 6 weeks to those at 1 year, there was significant improvement in all the five functional parameters (Table 3). At 1-year followup, the mean DASH score was 16 and Demerit pointsystemofsaitoyielded79%(n = 26)excellent,18% (n =6) good, and 3% (n =1) fair result. Three patients had lossofreductionatsubsequentfollowup;however,noneof our patients had tendon irritation/rupture, implant failure, or nonunion. 4. Discussion The importance of restoring the anatomical alignment and articular congruity is well recognised in the management of distal radial fractures [3]. Lafontaine in his study of 112 consecutive patients with fracture of the distal end of the radius suggested that the distal radius fractures with dorsal comminution are highly unstable and tend to suffer redisplacement following closed reduction [2]. Mackenney et al. reported that early instability was six times more common in fractures with any form of dorsal comminution [9]. Open reduction and internal fixation which allow better restoration and preservation of distal radius radiological parameters are recommended for this subset of unstable distal radius fractures [3, 10]. Significant controversy exists about whether dorsal or volar plating is superior for fixation of dorsally comminuted distal radial fractures [11 13]. Thoughdorsalapproachallowsfordirectarticularvisualization and placement of internal fixation as a dorsal buttress, allowing earlier return to activity, the outcomes tend to level off with time [14]. Prominent dorsal implant, extensor tenosynovitis, and rupture have been reported as complications after dorsal plating plate. Moreover, dorsally placed implants have increased thickness of the plate, raised screw heads, and they lack the ability to contour the plate to fit the bone[15, 16]. Though the advent of low-profile dorsal plates has solved this concern to some extent [11, 16], the very approach often requires dissection of the extensor retinaculum, and sometimes resection of the Lister s tubercle. Inthevolarapproach,thepronatorquadratusactsasa barrier by covering the distal edges of the plate, thereby minimising irritation to flexor tendons. As the volar cortex is relatively broad and flat as compared to the dorsal cortex of the distal radius, application of the volar locked plate is easy. In a biomechanical study on dorsally comminuted extraarticulardistalradialfracturescomparingdorsalt-platewith

ISRN Orthopedics 3 (a) (b) (c) Figure 1: (a) Preoperative radiographs of an AO type A3 fracture of the distal end of the radius in a 53-year-old male. (b) Postoperative radiographs showing adequate reduction. (c) Radiographs at the final followup, showing that the fracture has united and the radiological parameters are maintained. Table 3: Functional evaluation. 6weeks 1year Extension 44.16 ± 7.21 58.15 ± 7.83 Flexion 42.23 ± 9.62 54.62 ± 11.23 Supination 76.95 ± 4.11 84.23 ± 6.02 Pronation 72.10 ± 6.02 80.92 ± 5.54 Grip strength Absolute value in Kgs 10.62 ± 2.88 kg 21.53 ± 3.42 kg As a percentage of c/l side 44.26 ± 8.7% 92.26 ± 2.1% Kgs: kilograms; c/l: contralateral. volar locking plate, it was inferred that there was no difference in any of the biomechanical parameters, namely, stiffness, fragment displacement at 500 cycle-intervals, and axial load to failure between these constructs [13]. Volar plating preserves vascular supply to dorsal metaphyseal fragments and provides steady configuration, requiring less extensive dissection and thereby resulting in a low incidence of complications. In addition, the use of the volar approach is advantageous for restoring accurate rotational alignment because the volar surface of the distal radius is usually not comminuted. Anatomical reduction of the palmar cortex may also avoid the shortening of the radius, which is important to restore the radial length [17, 18]. The locking plate system provides a more secure and reliable fixation for comminuted fractures. The fixed plate screw construct with multiple screw options for easy application in distal complex fractures provides angular stability [3]. In a biomechanical study, it was found that volar locking provides significant resistance to fracture gap motion as compared to nonlocking plates [12]. Wefoundthatvolarlockingplateswereabletoattainand maintain good radiological and functional results (Tables 2 and 3), which supports the results in other series [4, 5, 19]. At final followup the average DASH score in the present series was 16 which is in consensus with other series [4]. Murakami et al. reported 83% excellent and 17% good outcome in their series of 24 patients of unstable distal radius fractures fixed with volar locking plate [5]. Rozental and Blazar reported 66% excellent and 44% good results in their series of 41 cases of dorsally displaced unstable fractures of the distal radius [4]. The results of our study are in consensus with them. In our series we had 3 cases of loss of reduction subsequently leading to malunion. The first case was a 33-year-old male who sustained AO type C3 fracture of the right wrist, with associated DRUJ (distal radioulnar joint) injury. This was the first case of the series and hence it formed a part ofourlearningcurve.wewereabletoobtainanadequate reduction for the distal radius; however, the DRUJ injury was missed by us. The radiographs obtained at subsequent followup visits revealed loss of reduction with dorsal subluxation of the carpus and DRUJ disruption (Figure 3). The fracture united but with deformity. At the final followup, the flexion extension arc was significantly less 52 though the rotations and grip strength were not affected much. This patient had a DASH score of 22. We, therefore, stress to the need to always check for the DRUJ injury in every case of distal radius

4 ISRN Orthopedics (a) (b) (c) (d) (e) (f) Figure 2: (a) Anterioposterior and (b) lateral views of wrist of a 35-year-old male with an AO/OTA type C3 fracture of the distal radius. (c), (d) Adequate reduction was achieved and open reduction and internal fixation of the fracture was done with volar locking plate and a K wire. (e), (f) Radiographs at the final followup showing union of the fracture. The locking plate was able to hold reduction till consolidation. fracture, as a missed DRUJ injury can be a disaster for both the patient and the doctor. The second case too was of an AO type C3 fracture in an eighteen-year-old male patient. Due to high-grade comminution, only one screw could be placed in the distal horizontal part of the plate. The initial radiographs confirmed adequate reduction. Subsequent X rays revealed that there was dorsal collapse of the fracture, which resulted in fracture healing in a residual dorsal tilt. The third case was again was an AO type C3 fracture in a 47-year-old male patient; there was dorsal settling of the fracture resulting in fracture healing in residual dorsal tilt. Despite this, the functional outcome remained favorable in these two patients, and the patients accepted the deformity well. The 9.09% incidence of loss of reduction in our series is comparable to that of Rozental and Blazer who reported, 4 instances of loss of reduction in 41 patients (9.75%) and Orby et al. loss of reduction in 3 out of 24 patients (12.5%) treated

ISRN Orthopedics 5 (a) (b) Figure 3: (a), (b) Radiographs at follow-up visit of an AO type C3 fracture of the right wrist which was fixed with volar locking plate. Though we were able to attain adequate reduction for the distal radius, the associated DRUJ (distal radioulnar joint) injury was missed by us. These radiographs show loss of reduction with dorsal subluxation of the carpus and DRUJ disruption. with volar locking plates [4, 19]. In the present series we did not have any case of hardware related complications or nonunion. When compared with previous reports on dorsal plating, volar plates appear to have a higher incidence of fracture collapse but a lower rate of hardware-related complications. Rozental and Blazer compared thier results of locked volar plating with those of dorsal plating for comminuted distal radius fractures. They identified that the overall complication rate in the volar plate group was 22% as compared to 32% in the dorsal plate group. Further, the volar plate cohort had a 10%rateoflossofreductionwhilethedorsallyplatedpatients did not experience any loss of reduction, malunion, or nonunion. They found a statistically significant difference in therateofsoft-tissuecomplicationsbetweenthe2groups; the volar plate group had a 7% rate of hardware removal secondary to tendon irritation while the dorsal plate group had a 32% rate of hardware-related tendon complications [4, 20]. We had our own set of limitations which included a small subset of patients and a relatively short followup of 1 year. Though studies have indicated that fragment displacement that occurs does so in the early periods of motion [13], still we intend to incorporate more patients and follow up these patients for a longer period. Another drawback is that it is a longitudinal study, not a comparative one; however, we have made an attempt to highlight the aspects of both dorsal and volar plating and compared the results with the literature. To conclude, patients with unstable, dorsally comminuted fractures of the distal radius treated with volar fixed angle plate have good to excellent functional outcomes despite a high incidence of loss of reduction and fracture collapse. This technique has its own learning curve, and it is highly recommended to check for associated DRUJ injuries. Our early results with this technique are fruitful, and we recommend it for the fixation of dorsally comminuted distal radius fractures. Conflict of Interests The authors declare that they have no conflict of interests. References [1] T. W. O Neill, C. Cooper, J. D. Finn et al., Incidence of distal forearm fracture in British men and women, Osteoporosis International,vol.12,no.7,pp.555 558,2001. [2] M. Lafontaine, D. Hardy, and P. Delince, Stability assessment of distal radius fractures, Injury, vol. 20, no. 4, pp. 208 210, 1989. [3] P.A.Martineau,G.K.Berry,andE.J.Harvey, Platingfordistal radius fractures, Orthopedic Clinics of North America, vol. 38, no. 2, pp. 193 201, 2007. [4] T. D. Rozental and P. E. Blazar, Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius, Hand Surgery, vol. 31, no.3,pp.359 365,2006. [5] K. Murakami, Y. Abe, and K. Takahashi, Surgical treatment of unstable distal radius fractures with volar locking plates, Orthopaedic Science, vol. 12, no. 2, pp. 134 140, 2007. [6] T.E.Trumble,S.R.Schmitt,andN.B.Vedder, Factorsaffecting functional outcome of displaced intra-articular distal radius fractures, Hand Surgery, vol.19,no.2,pp.325 340, 1994. [7] R. Arora, M. Lutz, A. Hennerbichler, D. Krappinger, D. Espen, and M. Gabl, Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate, Orthopaedic Trauma,vol.21,no.5,pp.316 322,2007.

6 ISRN Orthopedics [8] H. Saito and M. Shibata, Classification of fracture at the distal end of the radius with reference to treatment of comminuted fractures, in Current Concepts in Hand Surgery, J.A.Boswick, Ed., pp. 129 145, Lea&Febiger, Philadelphia, Pa, USA, 1983. [9] P. J. Mackenney, M. M. McQueen, and R. Elton, Prediction of instability in distal radial fractures, Bone and Joint Surgery. American, vol. 88, no. 9, pp. 1944 1951, 2006. [10] D. S. Ruch and T. A. Ginn, Open reduction and internal fixation of the distal radius, Operative Techniques in Orthopaedics, vol.13,no.2,pp.138 143,2003. [11] Y. R. Yu, M. C. Makhni, S. Tabrizi, T. D. Rozental, G. Mundanthanam, and C. S. Day, Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study, JournalofHandSurgery, vol. 36, no. 7, pp. 1135 1141, 2011. [12] A. A. Willis, K. Kutsumi, M. E. Zobitz, and W. P. Cooney III, Internal fixation of dorsally displaced fractures of the distal part of the radius: a biomechanical analysis of volar plate fracture stability, Bone and Joint Surgery. American,vol. 88, no. 11, pp. 2411 2417, 2006. [13] J. S. Gondusky, J. Carney, J. Erpenbach et al., Biomechanical comparison of locking versus nonlocking volar and dorsal T-plates for fixation of dorsally comminuted distal radius fractures, JournalofOrthopaedicTrauma,vol.25,no.1,pp.44 50, 2011. [14]Y.C.Chou,A.C.Y.Chen,C.Y.Chen,Y.H.Hsu,andC.C. Wu, Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures, Hand Surgery, vol. 36, no. 6, pp. 974 981, 2011. [15] J. B. Jupiter, Plate fixation of fractures of the distal aspect of the radius: relative indications, Orthopaedic Trauma, vol. 13, no. 8, pp. 559 570, 1999. [16] P. M. Simic, J. Robison, M. J. Gardner, R. H. Gelberman, A. J. Weiland, and M. I. Boyer, Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment, Hand Surgery,vol.31, no.3,pp. 382 386, 2006. [17]M.Kamano,Y.Honda,K.Kazuki,andM.Yasuda, Palmar plating for dorsally displaced fractures of the distal radius, Clinical Orthopaedics and Related Research, no.397,pp.403 408, 2002. [18] J. L. Orbay, The treatment of unstable distal radius fractures with volar fixation, Hand surgery,vol.5,no.2,pp.103 112,2000. [19] J. L. Orbay and D. L. Fernandez, Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient, Hand Surgery,vol.29,no.1,pp.96 102,2004. [20] T. D. Rozental, P. K. Beredjiklian, and D. J. Bozentka, Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius, Bone and Joint Surgery. American,vol.85,no.10,pp. 1956 1960, 2003.

MEDIATORS of INFLAMMATION The Scientific World Journal Gastroenterology Research and Practice Diabetes Research International Endocrinology Immunology Research Disease Markers Submit your manuscripts at BioMed Research International PPAR Research Obesity Ophthalmology Evidence-Based Complementary and Alternative Medicine Stem Cells International Oncology Parkinson s Disease Computational and Mathematical Methods in Medicine AIDS Behavioural Neurology Research and Treatment Oxidative Medicine and Cellular Longevity