Original Article Pulmonary vein isolation without left atrial mapping

Similar documents
Integration of CT and fluoroscopy images in the ablative treatment of atrial fibrillation

480 April 2004 PACE, Vol. 27

Image integration in catheter ablation of atrial fibrillation

Raphael Rosso MD, Yuval Levi Med. Eng., Sami Viskin MD Tel Aviv Sourasky Medical Center

Dr Mark Earley MD FRCP Consultant Cardiologist

5Real-time integration of

Ankara, Turkey 2 Department of Cardiology, Division of Arrhythmia and Electrophysiology, Yuksek Ihtisas

Supplementary Online Content

Catheter ablation of atrial macro re-entrant Tachycardia - How to use 3D entrainment mapping -

Catheter ablation of atrial fibrillation: Indications and tools for improvement of the success rate of the method. Konstantinos P.

Since pulmonary veins (PVs) have

Atrial Fibrillation: Electrophysiological Mechanisms and the Results of Interventional Therapy

The major thoracic veins, with their specific electrical

Mechanism of Immediate Recurrences of Atrial Fibrillation After Restoration of Sinus Rhythm

Characteristics of Rapid Rhythms Recorded Within Pulmonary Veins During Atrial Fibrillation

Take the online multiple choice mage registration is the process of aligning images. 1 2 During interventional procedures to

Intracardiac Echocardiography in Premature Ventricular Complex/Ventricular Tachycardia Ablation

AF ablation Penn experience. Optimal approach to the ablation of PAF: Importance of identifying triggers 9/25/2009

Catheter Ablation of Atrial Fibrillation in Patients with Prosthetic Mitral Valve

Atrial Fibrillation: Classification and Electrophysiology. Saverio Iacopino, MD, FACC, FESC

Accepted Manuscript. Inadvertent Atrial Dissociation Following Catheter Ablation: A Demonstration of Cardiac Anisotropy and Functional Block

20% 10/9/2018. Fluoroless Ablation relinquishing an old habit. Prevalence of Atrial Fibrillation. Atrial Fibrillation is a Progressive Disease

Electrical isolation of the pulmonary veins (PVs) to treat

Original Article Short- and long-term experience in pulmonary vein segmental ostial ablation for paroxysmal atrial fibrillation*

Topographic Distribution of Focal Left Atrial Tachycardias Defined by Electrocardiographic and Electrophysiological Data

The pulmonary veins have been demonstrated to often

Reversal of pulmonary vein remodeling after catheter ablation of atrial fibrillation

Catheter-Induced Linear Lesions in the Left Atrium in Patients With Atrial Fibrillation An Electroanatomic Study

CARDIOINSIGHT TM NONINVASIVE 3D MAPPING SYSTEM CLINICAL EVIDENCE SUMMARY

Electrical and Mechanical Insights of Human Atrial Fibrillation. Sághy László, MD. Summary of PhD Thesis

Clinical Value of Noninducibility by High-Dose Isoproterenol Versus Rapid Atrial Pacing After Catheter Ablation of Paroxysmal Atrial Fibrillation

Catheter Ablation of Atrial Tachycardia Originating from the Tip of Right Atrial Appendage

AF ABLATION Concepts and Techniques

Cardiology Department, Ain Shams University, Cairo, Egypt.

Noninvasive Visualization of the Cardiac Venous System Using Multislice Computed Tomography

ESSA HEART AND VASCULAR INSTITUTE APR/MAY/JUNE 2009 CLINICAL LETTER

Ablation of long-standing AF. Is it wise to pursue it?

Electrical disconnection of pulmonary vein (PV) myocardium

The impact of hypertension on the electromechanical properties and outcome of catheter ablation in atrial fibrillation patients

Time to recurrence of atrial fibrillation influences outcome following catheter ablation


A request for a log book extension must be put in writing and sent to BHRS, Unit 6B, Essex House, Cromwell Business Park, Chipping Norton,

Atrial Fibrillation Ablation Using a Robotic Catheter Remote Control System

Case Report Successful Multi-chamber Catheter Ablation of Persistent Atrial Fibrillation in Cor Triatriatum Sinister

Pulmonary vein isolation (PVI) is

Peri-Mitral Atrial Flutter with Partial Conduction Block between Left Atrium and Coronary Sinus

A Narrow QRS Complex Tachycardia With An Apparently Concentric Retrograde Atrial Activation Sequence

Peri-mitral atrial flutter in patients with atrial fibrillation ablation

From the Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Michigan

Introduction Atrial fibrillation (AF) can be effectively treated by catheter ablation. Typically, ablation targets the ostia of the pulmonary

Role of LAA isolation in AF cure

PRIMARY RESULTS OF RF CATHETER ABLATION FOR AF IN VIETNAM HEART INSTITUTE. PHAM QUOC KHANH, MD, PhD. et al Vietnam Heart Institute

A Cryo Anatomical Procedure to Everyone? Saverio Iacopino, FACC, FESC

Electrophysiological Characteristics of Atrial Tachycardia After Pulmonary Vein Isolation of Atrial Fibrillation

Case Report Electroanatomical Mapping and Ablation of Upper Loop Reentry Atrial Flutter

Case 1 Left Atrial Tachycardia

Image-guided Minimally-invasive Cardiac Interventions

LU:research Institutional Repository of Lund University

Is cardioversion old hat? What is new in interventional treatment of AF symptoms?

The Who, What, Why, and How-To Guide for Circumferential Pulmonary Vein Ablation

Case Report Figure-8 Tachycardia Confined to the Anterior Wall of the Left Atrium

Noncontact mapping to idiopathic VT from LCC

2017 HRS/EHRA/ECAS/APHRS/SOLAECE Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation

This overview was prepared in October 2011, and updated in March 2012.

Catheter Ablation of Supraventricular Arrhythmias: State of the Art

Succesful Radiofrequency Ablation of Atrial Tachycardia Arising From Within the Coronary Venous Sinus

CATHETER ABLATION FOR ATRIAL FIBRILLATION Patient Information Booklet

Noninducibility of Atrial Fibrillation as an End Point of Left Atrial Circumferential Ablation for Paroxysmal Atrial Fibrillation A Randomized Study

Comparative Effectiveness of Radiofrequency Catheter Ablation for Atrial Fibrillation Executive Summary

T he excess mortality associated with atrial fibrillation

Complications During Cardiovascular Interventions: Management and Prevention

Girish M Nair, Seeger Shen, Pablo B Nery, Calum J Redpath, David H Birnie

What s new in my specialty?

A New Approach for Catheter Ablation of Atrial Fibrillation: Mapping of the Electrophysiologic Substrate

New Parameter to Predict Recurrence of Paroxysmal Atrial Fibrillation after Pulmonary Vein Isolation by the P-Wave Signal-Averaged Electrocardiogram

Electrophysiologic Properties of Pulmonary Veins Assessed Using a Multielectrode Basket Catheter

Atrial fibrillation (AF) is the most common sustained arrhythmia in adults and

Case Report Epicardial Ablation: Prevention of Phrenic Nerve Damage by Pericardial Injection of Saline and the Use of a Steerable Sheath

Pulmonary veins CT: Imaging techniques, report and common ablation complications

Technique of Epicardial VT Ablation

Catheter Ablation for Treatment of Atrial Fibrillation 2010 and Beyond

INTRODUCTION. Key Words:

Radiofrequency ablation for atrial fibrillation

Case Report Substrate Based Ablation of Ventricular Tachycardia Through An Epicardial Approach

Atrial fibrillation ablation

Case Report Catheter ablation of Atrial Incisional Tachycardia mistaken for Atrial flutter

Basic Electrophysiology Protocols

How to ablate typical atrial flutter

Complex Left Atrial (CLA) Best Practices for Navigant

During the past 10 years, technology to fully register

Advanced imaging of the left atrium - strain, CT, 3D, MRI -

SEVEN YEARS OF CRYO-BALLOON CATHETER ABLATION

Hybrid Ablation of AF in the Operating Room: Is There a Need? MAZE III Procedure. Spectrum of Atrial Fibrillation

Electrogram-Guided Ablation

Cardiac Imaging in abnormal rhythm Role of MDCT

years ago an important study was published in the AJC which shows that, in red, you can see the musculature of vessels, or the thoracic veins, and

Debate-STAR AF 2 study. PVI is not enough

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Reversible mechanical atrioventricular block during cryoablation for paroxysmal atrial fibrillation with a 28 mm balloon

Transcription:

www.ipej.org 142 Original Article Pulmonary vein isolation without left atrial mapping Attila Kardos MD 1, Csaba Foldesi MD 1, Karoly Ladunga MSc, PhD 1, Attila Toth MD 2, Tamas Szili-Torok MD, PhD 1 1 Gottsegen Gyorgy Hungarian Institute of Cardiology 2 Semmelweis University, Department of Radiology Address for correspondence: Tamas Szili-Torok, MD, PhD, Gottsegen Gyorgy Hungarian Institute of Cardiology, Haller u. 29, H-1096, Budapest, Hungary. E-mail: szili.torok@kardio.hu Abstract Background: One of the crucial points during in most approaches developed for ablation of atrial fibrillation (AF) is the ability to identify the pulmonary vein (PVs) and to accurately locate their ostia. Objectives: The purpose of this case series was to investigate a simplified method for fusion of the multislice computer tomography (CT) derived 3D dataset with the electroanatomical map in order to facilitate the mapping procedure. Methods: In 5 consecutive patients (4 male) referred for catheter ablation of symptomatic drugrefractory paroxysmal atrial fibrillation contrast enhanced computer tomography was performed before the procedure and imported into an electroanatomical mapping system (Carto XP) using CartoMerge Image Integration Module. During the procedure a multipolar mapping catheter (Quick Star DS, Biosense Webster, Diamond Bar, CA, USA) was introduced to the coronary sinus (CS) to align the CSCT shell to the proper position. The CS potentials provided information to identify the ostium of the CS to achieve a more accurate fusion of the images. No mapping points were taken in the left atrium. The feasibility of the method was characterized by the distance of mapping points. Mapping, registration and outcome data were compared with a cohort of patients undergoing MRI image integration. Result: The mean distance between the mapping points taken in the CS by the Quick Star catheter and the CS CT surface was suitable (mean±sd, 1.4±0.3 mm). Full electrical isolation of the pulmonary veins could be achieved in all patients. The mean procedure and fluoroscopy time were 39 ± 22 and 134 ±38 min respectively, significantly decreased as compared to the MRI cohort. Conclusions: Highly accurate CT image and the electroanatomical map (EAM) fusion can be obtained by the Carto 3D electromanatomical mapping system using CS as the key anatomical structure for registration. Using this technique the mapping time of the left atrium can be reduced. Key Words: Pulmonary vein isolation; electroanatomical mapping; multislice computer tomography; image fusion

Attila Kardos, Csaba Foldesi, Karoly Ladunga, Attila Toth, Tamas Szili-Torok, 143 Pulmonary Vein Isolation Without Left Atrial Mapping Introduction Pulmonary vein isolation is an alternative therapeutic option for patients with atrial fibrillation 1. Although the outcome of patients undergoing different type of procedures shows progressive improvement, most of these methods remain rather complex, lengthy and carry a risk for even potentially lethal complications 2. Improved imaging has the ability to diminish complication rate and improve outcome 3-5. On the other hand extensive mapping procedure leads to an even longer procedure and fluoroscopy times. One of the new achievements in current imaging is the possible fusion between three dimensional off line CT or MRI images and electroanatomical maps. This reportedly increases procedural success 6,7. The potential advantages and pitfalls of current merge technology in the catheter based treatment of atrial fibrillation are well described. Especially image integration of the electroanatomic map with the CT/MR image needs structures' relative stability of motions (distal pulmonary veins, aorta) to achieve minimal registration error 5. The aim of the present study was to test a fundamentally different approach - i.e. coronary sinus registration - during image integration to simplify the merging process. In order to demonstrate its feasibility we present a case series of 5 patients undergoing image fusion using our new method. Methods Image integration After Institutional Review Board approval in five patients (mean age: 55±8 years) referred to our institute for catheter ablation of symptomatic drug-refractory paroxysmal atrial fibrillation, General Electric UltraSpeed 8-slice imaging instrument was used for contrast enhanced computer tomography (CT) before the procedure. Following administration of 100 ml non-ionic iodinated contrast material by a single barrel injector (Medrad) at flow rate of 4 ml/sec ECG-gated, low-pitch helical scan (SnapShot) was performed in the feet-head direction resulted in thin axial slices reconstructed at a specific delay. The CT images were imported into an electroanatomical mapping system (Carto XP, Biosense Webster, Inc., Diamond Bar, CA, USA) using Carto Merge Image Integration Module in the electrophysiologic workstation. The left and right atrium (LA, RA) and coronary sinus (CS) were segmented from other cardiac structures and their endocardial shell was extracted for image registration. In the electrophysiology lab the right internal jugular vein was cannulated, and the mapping catheter (Quick Star DS, Biosense Webster, Inc., Diamond Bar, CA, USA) was introduced to the CS via the right internal jugular approach before trans-septal puncture to fit the CS CT shell. The CS potentials provided information to identify the ostium of the CS to achieve a more precise fusion of the images. Mean distance between the mapping points taken in the CS by the Quick Star catheter and the CSCT surface was measured. Then the catheter was introduced into the inferior and superior vena cava for registration and after the trans-septal puncture through femoral venous access into the pulmonary veins (PVs) to check the accuracy (alignment) of the image registration. No any other mapping points were taken in the left atrium. During radiofrequency ablations to isolate the PVs the ablation points were taken to achieve further improvement of image integration (Figure 1). Radiofrequency catheter ablation Initially after two successful transseptal puncture a circular mapping catheter (Lasso, Biosense Webster, Diamond Bar, CA, USA) was placed into one of the pulmonary veins. Circumferential ablation lines were created using a 3.5 mm irrigation tip catheter (Navistar Thermocool, Biosense Webster, Diamond Bar, CA, USA ). After complete isolation of the

Attila Kardos, Csaba Foldesi, Karoly Ladunga, Attila Toth, Tamas Szili-Torok, 144 Pulmonary Vein Isolation Without Left Atrial Mapping pulmonary veins, further lines were undertaken based on the history of the patients. In persistent and permanent atrial fibrillation, mitral annulus, appendage isolation, roof line, posteroinferior transversal line was created (Figure 2). Figure 1. Cardiac CT derived endocardial shell of the heart reconstructed by Carto in postero-anterior view. Note the mapping catheter in the coronary sinus. Statistical analysis Data are reported as mean ± standard deviation. Procedural acute and follow up outcome data were compared with a cohort of 5 patients, where the image fusion was based on MRI images and was performed using full left atrial anatomical mapping using two-tailed Student t- test. Results The CS ostium could be cannulated in each patients with the multipolar mapping catheter. The average registration procedure was with minimum use of fluoroscopy was 5 minutes. Mean distance between the mapping points taken in the CS by the Quick Star catheter and the CS CT surface was 1.4 ±0.3 mm. The mean procedure time was 134±38 min. The mean fluoroscopy time was 39±22 min. All pulmonary veins could be electrically isolated in all patients (100%). 4 out of 5 patients had no recurrences during the mean follow up of 8 months (ranging 6-14). Two patients had early appearances of left atrial tachycardias. In one patient these arrhythmias disappeared spontaneously, while in another patient propafenone therapy was initiated, and the patient responded to this favorably. Outcome data comparing ablation result of the two groups are summarized in Table 1.

Attila Kardos, Csaba Foldesi, Karoly Ladunga, Attila Toth, Tamas Szili-Torok, Vein Isolation Without Left Atrial Mapping 145 Pulmonary Figure 2: Endoluminal view of the left sided pulmonary veins after successful complete electrical isolation.the red dots demonstrate the radiofrequency lesions. Table 1 *P<0.05

Attila Kardos, Csaba Foldesi, Karoly Ladunga, Attila Toth, Tamas Szili-Torok, Vein Isolation Without Left Atrial Mapping 146 Pulmonary Discussion The major finding of this study is that a simplified method for accurate fusion of MSCT images with electroanatomical mapping systems is feasible and indeed facilitates ablation procedures. Although the method requires further evaluation in a larger number of series it is a promising alternative to extensive and meticulous mapping of the left atrium in order to achieve acceptable fusion. The advantages of MSCT integration Accurate catheter position and discrimination between scar tissue and poor contact may facilitate ablation procedures in patients with dilated atria and complex anatomy. Image integration is a tool which potentially can fulfill the above mentioned requirements during ablations. Although prior publications have demonstrated the feasibility of image integration during PV isolation, these attempts were based on anatomical mapping utilizing a roving mapping catheter in the left atrium 5,7. Indeed, this results in an accurate fusion (i.e. registration), but lengthens the procedures significantly, in a situation where one of the major goal of further developments to diminish it. Our early experience shows that CT derived images can be precisely fused with the 3D electroanatomical map using the Carto 3D electroanatomical mapping system utilizing CS as the key anatomical structure for the registration process. The mapping time for pulmonary vein isolation can be dramatically reduced by this technique, as compared to the MR cohort. This seems to be a major advantage especially in patients where extensive ablation procedure is planned. Alternative possibilities This approach opens perspective for other type of arrhythmias as well. The same method can easily be applied for the mapping of right atrial tachycardias. During ablation of ventricular tachycardias using the retrograde transaortic route even the aorta can itself be used for facilitating the fusion. Our experience suggest, that indeed blood vessels visualized by the means of CT, can be used when the vessels has three dimensional configuration. Limitations of the study Although this initial experience is rather promising it seems however, results should be with caution since this was a small series study. The other main limitation of this study is that it was not randomized. However compared with a similar number of cohort using MRI registration (where coronary sinus was not available), the fluoroscopy and procedure times were significantly shorter. Finally, we do not have large number of patients to compare clinical outcome in order to be sure that shorter mapping will not be counteracted by the worsening of clinical outcome. In conclusion, the major finding of this study is that the method we developed seems to be technically feasible and our data suggest that indeed this shortens procedures and decreases fluoroscopy time. References 1. Fisher JD, Spinelli MA, Mookherjee D, Krumerman AK, Palma EC. Atrial fibrillation: reaching the mainstream. Pacing Clin Electrophysiol. 2006 ;29:523-37.

Attila Kardos, Csaba Foldesi, Karoly Ladunga, Attila Toth, Tamas Szili-Torok, 147 Pulmonary Vein Isolation Without Left Atrial Mapping 2. Lesaka Y. Complications of catheter ablation of atrial fibrillation: cause, prevention and management. J Cardiovasc Electrophysiol. 2006 ;17(Suppl 3):S50-5. 3. Sanders P, Stiles MK, Young GD: Virtual anatomy for atrial fibrillation ablation. J Cardiovascular Electrophysiol 2006;17:349-351. 4. Kistler PM, Earley MJ, Harris S, Abrams D, Ellis S, Sporton SC, Schilling RJ: Validation of three-dimensional cardiac image integration: Use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. J Cardiovascular Electrophysiol 2006;17:341-348. 5. Malchano ZJ, Neuzil P, Cury RC, Holmvang G, Weichet J, Schmidt EJ, Ruskin JN, Reddy VY. Integration of cardiac CT/MR imaging with three-dimensional electroanatomic mapping to guide catheter manipulation in the left atrium: Implications for catheter ablations of atrial fibrillation. J Cardiovascular Electrophysiol 2006.17.1221-1229. 6. Tops LF, de Groot NM, Bax JJ, Schalij MJ. Fusion of electroanatomical activation maps and multislice computed tomography to guide ablation of a focal atrial tachycardia in a fontan patient. J Cardiovasc Electrophysiol. 2006 ;17:431-4. 7. Burke MC, Roberts MJ, Knight BP. Integration of cardiac imaging and electrophysiology during catheter ablation procedures for atrial fibrillation. J Electrocardiol. 2006;39(4 Suppl):S188-92.