The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

Similar documents
The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

Eclipse Evoked Potential System. 10 reasons to choose

CE-Chirp. Making ABR fast, accurate and clear! Stimulus Family

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

OtoRead Portable OAE. More Time for Care. Optimized for Accuracy and Ease of use

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

Neuro-Audio Version 2010

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

A full product range for your every need. World leading diagnostic solutions

Protocol for Fast, Efficient Audiogram Prediction using Electrophysiology. Sponsored By

BIO-LOGIC PRO NAVIGATOR TRUSTED TECHNOLOGY. RELIABLE RESULTS.

A full product range for your every need. World leading diagnostic solutions

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

III. Comprehensive. Efficient. Auditory EP Testing

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

AC40. The true clinical. hybrid

AD629 The true hybrid

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

The Level Specific CE-Chirp

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Reliable, flexible & precise

myaudiometer. It s familiar, and it s so much

Additional Information Eclipse

Additional Information Eclipse

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

NEURO-AUDIO. Auditory EP (ABR, VEMP, ASSR, ECochG) and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

NEURO-AUDIO. Auditory EP (ABR, ASSR, ECochG), PTA and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research

by Maico Diagnostics

The Verification of ABR Response by Using the Chirp Stimulus in Moderate Sensorineural Hearing Loss

Handheld OAE-Tympanometry Combination System

Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)

ABR Screener Excellence in Newborn Hearing Screening

Unlock. your potential. Otometrics Madsen A450 the audiometer that works for you N O A H P M M R E P O R T I N G H I T C O U N S E L I N G

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

ERO SCAN. Otoacoustic Emission Testing

ABR Screener Excellence in Newborn Hearing Screening

Instructions for Use - EN Eclipse

UPDATE ON ELECTROPHYSIOLOGIC MEASURES OF HEARING SENSITIVITY IN INFANTS

(Otoacoustic Emissions and Automated ABR)

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

The following describes general use of ELIOS device

Experience the power of integration

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

Oscilla - excellence since 1960

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

User Manual. Neuro-Audio.NET UM ( )

Neurostyle. Medical Innovation for Better Life

Audiological Diagnosis after Newborn Screening

EASY. Comprehensive EP testing

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

Operation Manual. The Eclipse Platform EP15, EP25, TEOAE25, DPOAE20, ABRIS, ASSR. Introduction. The Eclipse Hardware and Software Installation

MES 9000 MUSCULOSKELETAL EVALUATION SYSTEM

BERA The HOMOTH ABR / BERA- module is a real time brainstem audiometer. It is developed considering the latest knowledge of the ENT research.

Instructions for Use Audiometric Data Interface

The true hybrid Stand alone & PC-based audiometry in one box

Comparison of Distortion Product Otoacoustic Emission Amplitude between Normal Hearing Male and Female Subjects

Quick Guide - eabr with Eclipse

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

ATMOS 360 diagnostics. Complete solution.

the truly automated all-in-one hearing screener

Simultaneous multiple stimulation of the auditory steadystate response (ASSR)

Toward Extending Auditory Steady-State Response (ASSR) Testing to Longer-Latency Equivalent Potentials

the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines

AC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

THRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST CONFIGURATIONS

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

Otoacoustic Emissions As A Test Of Noise-Induced Hearing Loss. Brenda L Lonsbury-Martin PhD

DOWNLOAD OR READ : VESTIBULAR EVOKED MYOGENIC POTENTIAL ITS BASICS AND CLINICAL APPLICATIONS PDF EBOOK EPUB MOBI

Additional Information Titan

The registration testing for audiometric device in CFDA

2) What is the most robust distortion product evoked with DPOAEs? A. F1 B. F2 C. 2F1-F2 D. 2F2 F1

Audiology Core Competencies Worksheet

Provisional guidelines for using Auditory Steady State Responses (ASSR) in babies. July 2009

Neurosurgical Review. CE-Chirp ABR in cerebellopontine angle surgery neuromonitoring: technical assessment in four cases.

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

AccuScreen ABR Screener

OPEN ACCESS GUIDE TO AUDIOLOGY AND HEARING AIDS FOR OTOLARYNGOLOGISTS

SLHS 588A Electrophysiologic Assessment Techniques: FALL Class Meeting: Room 229-SLHS, MW 2:00 to 3:15 p.m; Lab: TBA;

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

FALSE POSITIVE DP GRAMS

Auditory Assessment Based On EEG

OtoAcoustic Emissions (OAE s)

Improving the diagnostic power of otoacoustic emissions. Arturo Moleti Physics Department University of Roma Tor Vergata

Auditory Steady-State Response (ASSR): A Beginner's Guide by Douglas L. Beck, AuD, David P. Speidel, MS, Michelle Petrak, PhD

Advanced otoacoustic emission detection techniques and clinical diagnostics applications

Noise reduction in modern hearing aids long-term average gain measurements using speech

Transcription:

The Eclipse Designed to meet your every need AEP, ASSR, VEMP & OAE testing on one dedicated platform

Design your own diagnostic solution for a perfect result The Eclipse is a modern and versatile platform. It is designed to fit seamlessly into your everyday workflow and to offer complete reliability and perfect results. Have it your way We all strive towards a common goal: To achieve reliable test results to screen or diagnose patients accurately and efficiently. Whatever your challenge may be, the Eclipse hardware platform enables you to focus on the job at hand with the assistance of dedicated software modules for all facets of auditory evoked potentials and otoacoustic emissions. Making complicated things easy A range of pre-loaded test protocols are available in each software module ensuring that you will quickly feel confident. After getting acquainted with the software you can add or modify test protocols and tailor them to your specific needs. The clear layouts allow you to easily interpret the results and focus on the essential outcomes of the test, which can be saved into the OtoAccess TM database for easy retrieval, review and export to your EMR in XML format. Are you future-safe? Every Eclipse software module is developed based on proven technologies and feedback from users and audiology experts. Features are developed in sync with your changing needs and contain the latest technologies making the Eclipse a future-safe investment. A preview of the benefits Solid & noise immune hardware Modular and future-safe platform Unique pre-amplifier technology ensures optimum performance in electrically hostile environments Intuitive interfaces, well-designed layouts, freedom to customize settings 2

Silence is the Key The Eclipse preamplifier provides unrivalled stealth with very low internal noise 3

Software modules for any challenge Database NOAH Data Storage & Sharing OtoAccess TM Data Storage & Sharing Todd B. Sauter, M.A. Audiology Associates of Worcester Massachusetts The Eclipse has the largest number of clinically-relevant features of any AEP device today. The platform is an excellent blend of parameter flexibility and user-friendliness. 4

ABR EP25 ABR, MLR, LLR, P300, MMN, ECochG, eabr EP15 ABR ABRIS Automated ABR screening ASSR Threshold assessment OAE DPOAE Screening and clinical DPOAE TEOAE Screening and clinical TEOAE Balance VEMP cvemp ovemp 5

CE-Chirp Stimulus Family The Gold standard for threshold assessment Auditory Evoked Potentials Traditional Click CE-Chirp LS Stimulus 6

New technologies. New standards. New ABR. Residual Noise Calculation knowing when to stop Reducing noise is the single most important factor for improving any evoked potential recording. The residual noise calculator provides you with the knowledge of when to stop averaging, often saving test time and ensuring confidence in response identification. CE-Chirp Stimulus Family Double your response amplitudes The revolutionary CE-Chirp stimulus family for threshold assessment (developed by Claus Elberling) compensates for frequency specific cochlear travel times and generates waveform responses up to twice the size of traditional click or tone burst stimuli. The original CE-Chirp was designed for optimal response amplitude at medium stimulation intensities. By using the level specific CE-Chirp, clearer waveform morphology at high intensities is also available. The introduction of the CE-Chirp LS stimulus family is an overall improvement to the original CE-Chirp stimulus family. For an easier visual evaluation of the NB CE-Chirp responses, each of the NB CE- Chirp stimuli have been time shifted to provide latencies similar to Click and the CE-Chirp LS stimulus. The time-shifted NB CE-Chirp are named NB CE-Chirp LS, as the placements are level specific. Otherwise, the NB CE-Chirp LS are identical to the original NB CE-Chirp. The CE-Chirp stimulus family is incorporated in the EP25 (*optional for EP15) and ASSR software modules from Interacoustics. Bayesian Weighting saves you valuable time Using Bayesian Weighting during your ABR recording ensures that waveforms remain stable even during periods of patient activity. The influence of patient noise is minimized during the recording, resulting in continuously lower noise in the running average, saving valuable test time. Fmp improving confidence Imagine having an objective waveform confidence indicator to assist you in confirming the presence or absence of a response. The Fmp graph provides objective and mathematical information based on multiple points within the recording to assist with your waveform analysis. Use of the Fmp provides a reduction in test time and confidence in your diagnosis. The online display of the Fmp serves as a calculated response confidence. In this example, 99% response confidence was exceeded after only 1500 sweeps. Rather than testing for a certain number of sweeps, the residual noise should be used as a stop criteria. 7

EP15, EP25 and ABRIS From screening ABR to specialized AEP ABRIS Fast and objective ABR screening ABRIS is a fast screening software that can be used for all age groups. It returns a simple pass/refer result, requires minimal tester training and is automatic and objective. Just click START After attaching the electrodes and making a quick impedance check simply click Start and you are set to go. EEG monitoring is provided with a continuous graphical display and no measurements are collected during periods of unacceptable noise. Results are clearly displayed in: Green for Pass and Red for Refer it s that easy! 99.7% don t settle for less Vestibular EP We offer a special version for the vestibular clinic with protocols such as VEMP, ECochG and rate study tests. ABRIS specificity (the ability to correctly exclude normal hearing babies) is as high as 99.7% in large scale clinical trials using two stage screening. ABRIS sensitivity (the ability to correctly identify babies with hearing problems) is 99.99% based on large-scale simulations. 8

EP15 Diagnostic ABR EP25 Clinical AEP Developed for clinics performing standard threshold and neurological ABR testing, the EP15 will allow you to do a com mon task surprisingly well. For those who need specialized procedures requiring the full spectrum of AEPs: Go for the advanced EP25 software. A new standard The contemporary interface delivers unrivalled ease-of-use and superior clarity, which will help you achieve clear and reproducible results in a confident and timely manner. Pre-loaded protocols peer-reviewed by key-experts, easy tailoring of manual and automatic test protocols and a multitude of useful tools make the Eclipse the preferred choice for threshold and neurological ABR. For your daily routine Threshold & neurological ABR testing & eabr Bayesian weighting Residual noise calculator Fmp calculator SNR 3:1 ratio calculator CR, RA, INC waveform markers Normative latency data for click, CE-Chirp, NB CE-Chirp, CE-Chirp LS & NB CE-Chirp LS Single/split screen CE-Chirp, NB CE-Chirp, CE-Chirp LS & NB CE-Chirp LS for optimized threshold assessment (optional) CM & ECochG testing (optional) The benefits of specialized features The EP25 contains all the useful features found in the EP15, but adds the extra functionality needed by more specialized clinics. The EP25 incorporates a full range of test protocols covering the early, middle and late latency tests. EP25 all the features of EP15 and this: AMLR, ALLR & P300/MMN testing CM & ECochG testing ECochG Area Ratio Calculation by John Ferraro CE-Chirp, NB CE-Chirp, CE-Chirp LS & NB CE-Chirp LS for optimized threshold assessment Research module including waveform export, logging of recordings, and importing WAV files for stimuli (optional) Displaying Right and Left ear in a split screen format is beneficial when performing threshold work. Unique ECochG Area Ratio Calculation implementation. 9

ASSR Where speed meets accuracy The Interacoustics ASSR system reduces test times by 50% thanks to Narrow Band CE-Chirp stimuli and new powerful automated dual response detection methods. 10

A new (and faster) generation Interacoustics ASSR represents a true breakthrough and a new generation in ASSR threshold estimation. The ASSR software enables 8 frequencies to be tested simultaneously to threshold in less than 20-30 minutes through the use of Narrow Band CE-Chirp stimuli and a patented detection engine. Full control full speed You will dramatically shorten test time as you are in full control of selecting the appropriate stimulus levels independently for each frequency based on current and previous results. Also, you are able to change the stimulation rate during testing depending on the state of your patient. All in all: Full control allows full agility and speed. Cut test times in half The Interacoustics ASSR software uses the Narrow Band CE-Chirp stimuli to generate a maximal response, which makes the detection fast and efficient. The dual detection engine evaluates both the phase and the response magnitude from 12 of the higher harmonics of the fundamental modulation rate. This patented technology can reduce test time by 50% compared to traditional ASSR systems and offers unsurpassed accuracy. Save data directly to NOAH The estimated audiogram generated by the Interacoustics ASSR can be saved to NOAH. The estimated audiogram can easily be transferred to Genie or other similar hearing aid fitting software, ensuring a smooth and accurate hearing aid fitting. ASSR detection. ASSR audiogram. 11

12

DPOAE TEOAE Otoacoustic emissions DPOAE Distortion product emissions The Eclipse hardware platform accommodates both DPOAE & TEOAE capabilities. Shared features and benefits Lightweight probe with low internal noise Probe check indicator for correct 4 placement Historic overlay for test comparison Test summary providing a quick 4 overview of test results Protocol settings for automatic display 4 of pass/refer results for hearing 4 screening Weighted averaging improving data 4 quality and limiting the test time The DPOAE module produces detailed DP Grams with protocols designed by the user for their preferences or requirements. Confidence in the OAE measurements is ensured via DPOAE reliability criteria. Available frequency range is 500-10000 Hz. TEOAE Transient evoked emissions The TEOAE uses linear or non-linear broad band clicks to evoke otoacoustic emissions. The extensive range of clinical options provide a full clinical evaluation of TEOAEs. Available frequency range is 500-5500 Hz. 13

Optimize VEMP through visual feedback Vestibular Investigation The Eclipse ovemp and cvemp tests measure and analyse the vestibular evoked myogenic potential generated by a loud stimulus. Instant visual feedback increased quality Valid cvemp results are dependent on correct and controlled EMG tonus. The VEMP software provides visual feedback of the muscle contraction to assist you in helping the patient to obtain correct muscle tonus throughout the entire test. This can be done from the software or on a separate patient monitor for cvemp testing. Complete system Combine VEMP with the Interacoustics VNG system for a complete balance system. EMG-based scaling - a reliable result By applying EMG-based scaling of the obtained waveforms, you are ensured a crucially important balanced presentation of responses from Left and Right ensuring a confident and reliable result. High output stimuli The Eclipse VEMP (and ABR) can stimulate up to 100dB nhl with clicks and 110dB nhl with 250Hz-4kHz tonebursts. The B81 bone conductor can go up to 75dB nhl with 250Hz-4kHz tonebursts. Research module option Research module including waveform export, logging of recordings and importing WAV files for stimuli (optional). 14

Automated VEMP ratio calculation The amplitude difference between right and left side is calculated automatically using the VEMP ratio. Simply mark two places on the VEMP curve and the software will calculate the VEMP ratio.

Interacoustics Interacoustics is a world leading provider of diagnostic solutions in the field of hearing and balance assessment. Since 1967 we have designed and manufactured our innovative diagnostic solutions for the world of audiology with a constant focus on providing our customers with quality, dependable products. With you at all times We operate in over 100 countries worldwide through a carefully selected network of distributors and service centres. Purchasing an Interacoustics product guarantees not only a quality product, but also direct access to our highly professional training and support service. Product specifications All technical and hardware specifications concerning software modules and the Eclipse platform can be downloaded from our website. Read more at interacoustics.com Interacoustics A/S Audiometer Allé 1 5500 Middelfart Denmark T +45 6371 3555 F +45 6371 3522 info@interacoustics.com interacoustics.com Go online to explore our full product range ABR/OAE Balance Assessment Fitting Systems Middle Ear Analyzers Audiometers Interacoustics a/s - 8101800-6 - 06/2018