ALEXYS Neurotransmitter Analyzer

Similar documents
ALEXYS Neurotransmitter Analyzer for GABA & Glutamate, Histamine, LNAAs and other Amino Acids

Alexys Neurotransmitter Analyzer for Monoamines and Metabolites

ALEXYS Neurotransmitter Analyzer for Monoamines and their Acidic Metabolites

ALEXYS Neurotransmitter Analyzer for On-line Microdialysis Sampling

Applications Notebook

Aminothiols and Disulfides

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Bisphenol A in Drinking Water

A Rapid UHPLC Method for the Analysis of Biogenic Amines and Metabolites in Microdialysis Samples

Iodide in Milk. Electrochemistry Discover the difference

Comparison of a UPLC Method across Multiple UHPLC Systems

Serotonin in Urine. Electrochemistry Discover the difference

APPLICATION NOTE COMPILATION OF NEUROSCIENCE APPLICATIONS 213_026 #01

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Articaine & Epinephrine Injection According to USP Method

Betadex Sulfobutyl Ether Sodium according to USP

HTEC-500 and 700 Series Related

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Fast UHPLC Methods for Analysis of Amino Acids

Simultaneous Analysis of Norepinephrine, Dopamine and Serotonin in 15 Minutes

Mercaptoethanesulfonic acid as the reductive thiol-containing reagent employed for the derivatization of amino acids with o-phthaldialdehyde analysis

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

The Raptor HILIC-Si Column

Suven Microdialysis Services

Abstract. Introduction

Extended Temperature Range Impact on HPLC Column Stability and Performance

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Extended Application Note

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Metanephrines. in Urine. Clinical & Diagnostics Analysis. Introduction. Application Note ALEXYS - Clinical & Diagnostics

Impurity Profiling of Carbamazepine by HPLC/UV

Agilent 1220 Infinity LC System Performance Specifications

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Authors. Abstract. Introduction. Food

HVA, VMA and 5-HIAA in Urine

Serotonin in Plasma. Electrochemistry Discover the difference. Summary. Application Note Clinical & Diagnostics

Am I getting the very best value from my UHPLC analyses?

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Raptor HILIC-Si: Simplify the Switch to HILIC

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Authors. Abstract. Introduction. Environmental

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

High Throughput simultaneous analysis of 39 amino acids in various foods without derivatization using LC-MS/MS

The LC Column Playbook

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Analysis of L- and D-Amino Acids Using UPLC Yuta Mutaguchi 1 and Toshihisa Ohshima 2*

Columns for HPLC. Columns for HPLC

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

vii LIST OF TABLES TABLE NO DESCRIPTION PAGE 1.1 System Suitability Parameters and Recommendations Acidic and Alkaline Hydrolysis 15

Hyper-fast & Super-rugged

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

The One Minute Chromatographer

LC/MS Method for Comprehensive Analysis of Plasma Lipids

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC

Analysis of bisphenol A leaching from baby feeding bottles

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

Mono- and Disaccharides

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Dienes Derivatization MaxSpec Kit

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Determination of Amantadine Residues in Chicken by LCMS-8040

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

Edgar Naegele. Abstract

Raptor HILIC-Si: Simplify the Switch to HILIC

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Utility of Pentafluorophenylpropyl Stationary Phases for RP-HPLC Analyses: Biogenic Amines on Discovery HS F5

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

2D-LC as an Automated Desalting Tool for MSD Analysis

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

Determination of glycerol derivatives by High-performance liquid chromatography

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Transcription:

Application Note Neuroscience ALEXYS Analyzer for Highest Sensitivity in Neurotransmitter Analysis ALEXYS Neurotransmitter Analyzer Monoamines and Metabolites Noradrenaline Dopamine Serotonin 5-hydroxyindole aceticacid () 3,4-dihydroxyphenylaceticacid () homovanillic acid () OPA derivatized amines and amino acids GABA and Glutamate Histamine (LAs) 4-aminobutyrate (GABA) Glutamate (Glu) LAs Choline and Acetylcholine Choline (Ch) Acetylcholine (ACh) Markers for oxidative stress 3-nitro-L-Tyrosine 8-OH-DPAT Glutathione and other thiols n UHPLC, fast and sensitive n Modular, covering most relevant neurotransmitters n New methods for ACh, GABA, and Glu n Neurosep column for Monoamines Summary The ALEXYS Neurotransmitter analyzer is a modular system that can be customized for a specific neurotransmitter, or group of transmitters. The system consists of the OR 11 degasser unit, LC 11S pump(s), the AS 11S autosampler, the DECADE II EC detector and Clarity data acquisition software. Complementary kits have been developed for common neurotransmitters such as epinephrine, norepinephrine, serotonin and metabolites, GABA and glutamate or acetylcholine and choline. ALEXYS Application Note # 213_27_2 Electrochemistry Discover the difference

Introduction With the introduction of UHPLC the improved peak efficiency of the sub 2 micron particles has become available. According to the van Deemter equation, these small stationary phase particles not only result in a significant gain in efficiency, but the efficiency does not diminish at increased flow rates or linear velocities. This offers new possibilities to further improve neurotransmitter analyses with respect to separation efficiency, retention time and detection sensitivity. A new ALEXYS Analyzer has been developed for a number of well-known neurotransmitters and metabolites which uses a UHPLC system with sub-2 μm packed columns to optimize plate numbers, retention times and detection sensitivity. Detection limits down to the lower pmole/l range have been achieved for several neurotransmitters. When OPA derivatization is involved the LOD is around 1 nmole/l (GABA and glutamate, amino acids), in case of enzymatic conversion the LOD is around.5 nmole/l (acetylcholine). UHPLC methods UHPLC is characterized by extremely efficient separations in a short period of time and plate numbers of more than 1, /m can be obtained using sub 2 um particles. As a consequence, every detail in the flow path has to be optimized as it can become a bottle neck in getting the best possible separation performance. Typically, tubing dimensions need to be smaller than 1 um, and loadability (injection volume) is limited. The peak efficiency or plate number N is described as the square of the retention volume (Vr) devided by the peak dispersion σ. N = [ V R / σ ] 2 Peak broadening has been described [1, 2] as the sum of all individual dispersion contributions (σ tot2 ) from injection (σ inj2 ), tubing (σ tub2 ), column (σ col2 ) and detection (σ det2 ). 2 2 2 2 2 σ tot = σ col + σ inj + σ tub + σ det [na] 1..5. -.5 1 mm/sec Figure 1: ALEXYS Neurotransmitters Analyzer. -1. -1.5 4 mm/sec -2. 5 1 15 2 Figure 2: Fast HPLC of neurotransmitters with 8, -14, tp/m. 2

To fully benefit from the improved column efficiency the others (injection, tubing, detection) must keep up to the same level. 2 σ tub = c L F d 4 where L is length and d is diameter of tubing, F is flow rate, and the constant c is π / 384 D (D is diffusion coefficient). Dispersion by injection is directly proportional to the square of injection volume, and the same holds for detection in relation to detection cell volume. 2 2 σ inj = a V inj 2 2 σ det = b V det where a and b are constants. This has a few practical implications when using UHPLC. Firstly, an increased flow rate in combination with small tubing diameter and a small particle size of stationary phase will contribute considerably to the system pressure. Therefore, the pump, injection valve, all tubing, nuts and ferrules must be rated for high pressure. Where possible the acetonitrile/water mixtures which have a low viscosity are used as mobile phase, instead of methanol/water to minimize the pressure increase. In addition, an elevated temperature (35 45 C) is sometimes applied for the same reason. Figure 3: Dispersion by tubing. 6 um vs 25 um tubing. Secondly, the fast separation and high plate numbers will have an impact on the signal to noise ratio. The peak height improves with the square root of the plate number, the loadability is limited to a few microliters to maintain the high plate number. Only under stacking conditions larger injection volume can be applied without losing a significant number of plates. 25 2 Plate number (N) 15 1 5 2 4 6 8 1 Injection volume (µl) Figure 4: Injection volume affects plate count. Plot shows theoretical relationship; for peak eluting at 2 min at a flow rate of 15 ul/min on a column with 2 plates. 3

It should be noted that the use of a low pass noise filter is limited. By design, low pass frequency filters will attenuate high frequency signals including narrow peaks. As a rule of thumb the maximum allowed filter setting is related to retention time and inversely related to the square root of N. τ < c t R / N where c is.32 for max 1% loss in plate number. Firstly, to improve detection of peaks close to the solvent front, as a rule of thumb acidified samples should not contain more than 1 mmole/l acid (end concentration). Secondly, the salt bridge is to be preferred over the ISAAC (In Situ Ag/AgCl) reference electrode when peaks of interest are eluting rapidly. With the salt bridge, the baseline recovers quicker from the solvent front destabilization. Thirdly, the injection volume has an effect, smaller is better. For a regular HPLC peak showing 4 plates at 1 min retention time, the application of a time constant of 3 sec is allowed. In UHPLC a peak with the same plate number but 1. min retention time, the maximum time constant is.3s. using a stronger filter setting would lead to significant loss of signal. Traditional noise filters will be useless in case of very fast separations. In some cases of very fast peaks a high frequency of data acquisition will be required, which usually increases the noise. This means in some cases a compromise must be found between detection limits, and speed of analysis. Voltage Voltage [mv] 6 4 2.8-2 -4 Reference electrode: ISAAC/8 mm Cl - Normal flow rate 2 4 6 8 1 12 14 [mv] Reference electrode: ISAAC/8 mm Cl - 6 55.8 Sample matrix conditions Microdialysate samples are 1% aqueous with a high concentration of salts (~15 mm). Collection and storage of samples from microdialysis usually requires precautions to avoid auto oxidation and degradation of substances of interest (e.g. catecholamines are prone to oxidation). Several authors report that their antioxidant mix contain either formic acid, or acetic acid or citric acid in combination with ascorbic acid or another anti-oxidant. This acidic/salty sample matrix has a considerable impact on the system peaks close to the solvent front and elsewhere in the chromatogram. In some cases, the presence of interfering peaks can be manipulated by the octane sulfonic acid (OSA) concentration to the mobile phase. If that approach is not successful other recommendations can be made. Voltage 5 [mv] 1 5-5 1 2 3 4 1 2 3 4 3.5 x Normal flow rate Reference electrode: Salt bridge 3.5 x Normal flow rate Figure 5: Analysis of 1 nmole/l standards in Ringer with 1 mmole/l HAc. In case of ISAAC the peak disappears in the front with increased flow rate. 4

Optimization of separation conditions [pa] Most neurotransmitters are very polar, and ion pairing chromatography on a (special) C18 column is the separation method of choice in most cases. In addition to the ion pair concentration, the modifier percentage and ph affect separa- 4 2 tion. 35 C -2-4 45 C -6 * * * * 5 1 15 2 25 Figure 7: Effect of column temperature on separation. Figure 6: Effect of octane sulfonic acid (OSA) concentration in the mobile phase on neurotransmitters and baseline disturbance (*) elution. Retention of acidic metabolites (e.g.,, ) is selectively affected by ph on a C18 column: retention increases with lower ph due to the protonation of the carboxyl group in these components. The retention time of the derivatized amino acids (Glu, Asp, Gly etc) also responds to ph, the response is component dependent. The retention of amines such as dopamine, noradrenaline, serotonin, choline and acetylcholine selectively increases with the ion pair concentration. Optimization of separation conditions can be a time consuming part of method development. Antec s application notes already describe the optimized conditions: however, chromatograms of real life samples may show interfering peaks, requiring further optimization. An alternative dual channel approach, that is especially useful for very complex samples has been described elsewhere (Antec application note 213_18). Temperature is another parameter that can be modified. Higher temperatures results in faster elution. Separation between peaks can also be affected, as for instance the retention of serotonin is changed more significantly than that of the other components (Fig. 7). 5 5

Monoamines,, and For simultaneous analysis of noradrenaline, dopamine and serotonin in microdialysis samples a fast HPLC method has been developed. One of the challenges is to separate from the front peak and keep within reasonable retention time. GABA and glutamate The analysis of GABA and glutamate is based on an automated in-needle derivatization routine with OPA reagent, followed by a fast HPLC separation. A short post-analysis step gradient is applied to flush late eluting peaks off the column. [na].8 [pa] 15 [na] [na ] 1.1.6.4.2 1 5 1 8 Glu 1..9.8.7 GABA. 6.6 2 4 6 8 1 2 4 6 8 1 2 4 6 8 1 12 Figure 8: On the left analysis of 1 nmole/l standards in acidified Ringer. On the right a real sample: microdialysate of rat brain. 4 2 Detection limit of, and is around 1 pmole/l (s/n=3). Linearity shows a correlation coefficient better than.999 in the range of.1 to 1 nmole/l. The relative standard deviation (RSD) is better than 2% for mid-range concentrations (5 nmole/l). 2 4 6 8 1 12 Figure 1: Example chromatogram of the analysis of GABA and Glu in pooled rat dialysate from the Nucleus Accumbens. Detection limit of GABA and Glu is around 1 nmole/l (s/n=3). The linearity of the method was determined in the concentration ranges of.5-2.5 μm and 1-5 nm for Glu and GABA respectively. The method showed a good linear detector response with correlation coefficients better than.998 for both GABA and Glu. Figure 9: Standard mixture of 1 nmole/l neurotransmitters and metabolites. In principle, all amino acids can be detected with this method. Two other relevant amino acid neurotransmitters are aspartate (Asp) and glycine (Gly), and with some modification to the separation parameters, this method can also be applied to detect those. 6

Acetylcholine and choline For the analysis of acetylcholine, a reversed phase ion-pairing separation method was evaluated. The method has a few interesting features compared to the ion-exchange separation method. The use of an analytical micro-bore UHPLC C18 column which allows for faster separations and a mobile phase of ph 6.5 is used, which compared to the traditional method at ph 8 improves lifetime of the IMER. Also the working potential is optimized for much better signal-to-noise ratio. For detection, a glassy carbon working electrode must be coated with peroxidase, and after a drying period of about 4 hours the electrode is ready for use. Detection limit of Acetylcholine is around.5 nmole/l (s/n=3). Linearity shows a correlation coefficient better than.998 in the tested range of.5-2 nmole/l. The relative standard deviation (RSD) is better than 4% (tested with 1 nmole/l). As acetylcholine is not readily detectable, it is first converted to the electrochemically detectable hydrogen peroxide. The enzymatic conversion takes place in a post column AChE/ ChOx IMER. [na] [pa] 1 Ch 6 Ch 8 4 6 4 2-2 1 2 3 4 ACh 1 2 3 4 5 2 ACh Figure 11: Chromatogram of 2 umole/l Choline and 2 nmole/l Acetylcholine in Ringer solution. The inset shows the same chromatogram, but zoomed in on the baseline. Conclusion Fast and sensitive analysis of a number of neurotransmitters has been demonstrated using the ALEXYS Neurotransmitter Analyzer. It is a modular system with complementary kits for the most common neurotransmitters. [pa] 1 Ch 5-5 ACh -1-15 -2 1 2 3 4 5 Figure 12: Chromatogram of 2 umole/l Choline and 2 nmole/l Acetylcholine in Ringer solution. The inset shows the same chromatogram, but zoomed in on the baseline. 7

References 1. K. Slais and D. Kourilova, J. of Chromatogr., Minimisation of extra-column effects with microbore columns using ECD, 258 (1983) 57-63 2. K. Slais, Small-bore LC/EC, J. of Chromatogr. Sc., 24 (1986) 321-329 3. Anja Pruss, Christine Kempter, Jens Gysler, Thomas Jira, Extracolumn band broadening in capillary chromatography, J. Chromatogr. 116 (23) 129-141 4. H. L. Rowley, K. F. Martin, C. A. Marsden, Determination of in vivo amino acid neurotransmitters by high-performance liquid chromatography with o-phthalaldehyde-sulphite derivatization, J. of Neurosc. Meth. 57 (1) (1995) 93-99 5. W.A. Jacobs, o-phthalaldehyde-sulfite derivatisation of primary amines for liquid chromatography-electrochemistry, J. Chromatography, 392 (1987) 435-441 6. S. Smith, T. Sharp, Measurement of GABA in Rat Brain Microdialysates Using o-phthaldialdehyde Sulphite Derivatization and High- Performance Liquid Chromatography with Electrochemical Detection, J. Chromatography B, 652 (2), (1994) 228-233 7. Dimitri De Bundel, Sophie Sarre, Ann Van Eeckhaut, Ilse Smolders and Yvette Michotte, New antioxidant mixture for long term stability of serotonin, dopamine and their metabolites in automated microbore liquid chromatography with dual electrochemical detection, Sensors 28, 8(8), 5171-5185 8. Handbook of Microdialysis, Volume 16: Methods, Applications and Perspectives (Handbook of Behavioral Neuroscience), Ben HC Westerink, Thomas I.F.H. Cremers (ed.) Academic Press (27). 9. A.T. Nguyena, T. Aertsa, D. Van Dam and P.P. De Deyn, Biogenic amines and their metabolites in mouse brain tissue: Development, optimization and validation of an analytical HPLC method, Journal of Chromatography B Volume 878, Issue 29, 1 November 21, Pages 33-314 Ordering Information Monoamines and metabolites 18.91E ALEXYS Neurotransmitters BP, 1 ch 191.35UL AS 11 autosampler UHPLC cool 6p, LAN 18.52 ALEXYS Monoamines kit GABA and glutamate 18.91E ALEXYS Neurotransmitters BP, 1 ch 191.35UL AS 11 autosampler UHPLC cool 6p, LAN 18.54 ALEXYS GABA/Glu kit 18.62 LC step-gradient upgrade Acetylcholine and choline 18.91E ALEXYS Neurotransmitters BP, 1 ch 191.35UL AS 11 autosampler UHPLC cool 6p, LAN 18.55 ALEXYS Acetylcholine kit 25.3531 AChE/ChOx IMER 3mm Antec Scientific (USA) info@antecscientific.com www.antecscientific.com T 888 572 12 Antec Scientific (worldwide) info@antecscientific.com www.antecscientific.com T +31 71 5813333 For research purpose only. The information shown in this communication is solely to demonstrate the applicability of the ALEXYS system. The actual performance may be affected by factors beyond Antec s control. Specifications mentioned in this application note are subject to change without further notice. 8