Laboratory Name: Laboratory Address: Date of this packet: Insert Revision: IN Rev /12

Similar documents
QUICK REFERENCE INSTRUCTIONS For use with Sofia only.

QUICK REFERENCE INSTRUCTIONS

QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only

Address: BinaxNOW Influenza A & B Laboratory Procedure

Influenza A & B Screening

Rapid-VIDITEST. Influenza A+B

CLIA Waived for swab samples Non-Waived for Nasal Aspirate/Wash and swabs stored/transported in media.

Sofia Influenza A+B FIA

Rapid-VIDITEST. Influenza A

G1 - Specimen collection

SAMPLE PROCEDURE 907-9, 06/11

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

Human Influenza A (Swine Flu) Rapid test

Rapid-VIDITEST Swine Flu

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

IMMUVIEW S. PNEUMONIAE ANTIGEN TEST. Lateral flow test for qualitative detection of S. pneumoniae in urine and cerebrospinal fluid.

CLIA Complexity: MODERATE INTENDED USE SUMMARY AND EXPLANATION FOR INFORMATIONAL USE ONLY FOR INFORMATIONAL USE ONLY

CLIA Complexity: WAIVED. For in vitro use only.

IMMUVIEW L. PNEUMOPHILA AND L. LONGBEACHAE URINARY ANTIGEN TEST. SSI Diagnostica

IMMUVIEW S. PNEUMONIAE AND L. PNEUMOPHILA URINARY ANTIGEN TEST. SSI Diagnostica ENGLISH

PROCEDURE MANUAL. Prepared By Date Adopted Supersedes Procedure # Review Date Revision Date Signature

contact your Medicare and B viral directly from samples. viruses: A, B,

Influenza A&B Test. Place test stick (arrows pointing downward) buffer. Read results. Read results Add Test Stick. into the tube with. at 10 minutes.

IMMUVIEW. S. pneumoniae and L. pneumophila Urinary Antigen Test ENGLISH

Rapid Detection FAQs

DETERMINE SPECIMEN REQUIREMENTS HIV-1/2 Ag/Ab Combo TESTING PROCEDURE

CLIA Complexity: WAIVED

October Influenza Testing for the Season. Lauren Anthony, MD, MT(ASCP)SBB Medical Director, Allina Medical Laboratories

Rapid-VIDITEST. Strep A Blister. One step Strep A Blister for the detection of Group A Streptococcal antigen from throat swabs or culture.

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

SAMPLE PROCEDURE , 07/11

MEETING THE STANDARDS: FDA MANDATORY RAPID INFLUENZA DETECTION TEST (RIDTs) RECLASSIFICATION

INFINITI FLU A-sH1N1 Assay Directional Package Insert (DPI)

IMMUVIEW S. pneumoniae and L. pneumophila UrInary antigen test

Pediatric Infections caused by the Swine-Origin Influenza A (H1N1) Virus (S-OIV) 5/1/09 Update

Protocols for Laboratory Verification of Performance of the BioFire FilmArray Pneumonia Panel plus

SAMPLE PROCEDURE , 07/11

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

AN IMMUNOASSAY TEST FOR THE QUALITATIVE DETECTION OF STREP A ANTIGEN IN THROAT SWAB SPECIMENS

Lab Alert REMINDER: BioFire- FilmArray Respiratory Panel

Protocols for Laboratory Verification of Performance of the FilmArray Respiratory Panel 2 plus (RP2plus)

Rapid-VIDITEST. Strep A Card. One step Strep A Card for the detection of Group A Streptococcal antigen from throat swabs or culture.

Simplexa Flu A/B & RSV Direct

Protocols for Laboratory Verification of Performance of the BioFire FilmArray Pneumonia Panel

Rapid-VIDITEST Shigella dysenteriae

Chlamydia trachomatis (CHLa)Test Kit

Guidelines for Sample Collection and Handling of Human Clinical samples for Laboratory Diagnosis of H1N1 Influenza

Protocols for Laboratory Verification of Performance of the FilmArray Respiratory Panel (RP) EZ

cobas Liat System Lab in a tube

For use with Sofia only

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

QUICK REFERENCE INSTRUCTIONS. THYROCHEK TSH Cassette

Rapid-VIDITEST. Helicobacter pylori. One step Helicobacter pylori Blister test. Instruction manual

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

Strep-a-Test Twister Test

INSTANT-VIEW H. pylori Rapid Test CLIA WAIVED Test for Whole Blood QUALITATIVE IN-VITRO DIAGNOSTIC TEST FOR EXTERNAL USE ONLY

T R A I N I N G G U I D E

Rapid-VIDITEST Enterovirus

Next Generation Rapid Diagnostics

Tips for Training New Customers

Respiratory Pathogen Panel TEM-PCR Test Code:

CLIA Complexity: WAIVED

Retrospective and Prospective Verification of the Cepheid Xpert Flu Assay

Protocols for Laboratory Verification of Performance of the FilmArray Respiratory Panel (RP)

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

Veritor System. For Rapid Detection of Flu A+B

2009 H1N1 Influenza ( Swine Flu ) Hemagglutinin ELISA kit

INFLUENZA A&B TEST. For use with the Silaris Dock REAGENTS AND MATERIALS. CLIA WAIVED: For use with Nasal Swabs MATERIALS PROVIDED

Sofia Lyme FIA. For use with Sofia Analyzer only CLIA Complexity: Moderate for serum and plasma specimens

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

LABORATORY PROCEDURE DIRECTIGEN FLU A FOR THE DIRECT DETECTION OF INFLUENZA A ANTIGEN

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Rapid-VIDITEST. Rota-Adeno Blister. One Step Rotavirus and Adenovirus Antigen Blister test. Instruction manual

AVIAN INFLUENZA COMMODITIES TRAINING GUIDE MODULE 3 - SAMPLING, RAPID TESTING AND PACKAGING PARTICIPANT HANDOUTS

Helicobacter pylori Antigen Test

WHO biosafety risk assessment and guidelines for the production and quality control of human influenza pandemic vaccines: Update

Hepatitis C Virus (HCV) Antibody Test

TB LAM Ag Lateral Flow Assay Standard Operating Procedure

Influenza A H1N1 (Swine Flu 2009) Hemagglutinin / HA ELISA Pair Set

Redefine Performance. BD Veritor. System Revolutionizes Testing at the Point of Care. Fast. Streamlined Workflow Requires minimal hands-on time

NEGATIVE POSITIVE. Rev , 06/11. 5 min. Mono Test. For fi ngertip. blood: 1 DROP 1 DROP For serum, whole blood. plasma or. samples.

Product Training & Certification

ONE-STEP WHOLE BLOOD H.PYLORI TEST. Product Code: 24529

NEPHROCHECK Liquid Control Kit Package Insert

Mono Test 1 DROP 1 DROP. For fingertip blood: For serum, plasma or whole blood samples in tubes: Rev , 05/09

Influenza A IgG ELISA

25 OH Vitamin D Rapid test

Procine sphingomyelin ELISA Kit

NEPHROCHECK Calibration Verification Kit Package Insert

FAQ and Answers WOUNDCHEK Protease Status; Rev 6; Mar

Guidance for Influenza in Long-Term Care Facilities

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

For use with Sofia 2 CLIA Complexity: Waived for Finger-stick Whole Blood

Insulin (Porcine/Canine) ELISA

Texas Influenza Summary Report, Season (September 28, 2008 April 11, 2009)

Items in the package:

Human Cytomegalovirus IgM ELISA Kit

Bovine Insulin ELISA

Transcription:

Laboratory Name: Laboratory Address: Date of this packet: Insert Revision: IN575000 Rev. 1 2017/12 Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader Laboratory Procedure Re-order numbers: #575-000 Alere BinaxNOW Influenza A & B Card 2 (22 Tests) #575-080 Alere BinaxNOW Influenza A & B Card 2 Control Swab Kit This procedure is intended to provide a ready outline reference for performance of the assay. These abbreviated directions for use are not intended to replace the complete package insert. Any modifications to this document are the sole responsibility of the Facility. For use with nasal or nasopharyngeal swab specimens For in vitro use only Rx Only CLIA Complexity: Waived A Certificate of Waiver is required to perform this test in a CLIA Waived setting. To obtain CLIA waiver information and a Certificate of Waiver, please contact your state health department. Additional CLIA waiver information is available at the Centers for Medicare and Medicaid website at www.cms.hhs.gov/clia. Failure to follow the instructions or modification to the test system instructions will result in the test no longer meeting the requirements for waived classification. 1. Intended Use The Alere BinaxNOW Influenza A & B Card 2 is an in vitro immunochromatographic assay for the qualitative detection of influenza A and B nucleoprotein antigens in nasopharyngeal (NP) swab and nasal swab specimens. It is intended to aid in the rapid differential diagnosis of influenza A and B viral infections. Negative test results are presumptive and should be confirmed by cell culture or an FDAcleared influenza A and B molecular assay. Negative test results do not preclude influenza viral infection and should not be used as the sole basis for treatment or other patient management decisions. Alere BinaxNOW Influenza A & B Card 2 must be read by the Alere Reader. Performance characteristics for influenza A were established during the 2015-2016 influenza season when influenza A/H3N2 and A/H1N1 pandemic were the predominant influenza A viruses in circulation. When other influenza A viruses are emerging, performance characteristics may vary. If infection with a novel influenza A virus is suspected based on current clinical and epidemiological screening criteria recommended by public health authorities, specimens should be collected with appropriate infection control precautions for novel virulent Influenza viruses and sent to state or local health department for testing. Viral culture should not be attempted in these cases unless a BSL 3+ facility is available to receive and culture specimens. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 1

2. Summary and Explanation of the Test Influenza is a highly contagious, acute, viral infection of the respiratory tract. It is a communicable disease that is easily transmitted through the coughing and sneezing of aerosolized droplets containing live virus. Influenza outbreaks occur each year during the fall and winter months. 1 Type A viruses are typically more prevalent than type B viruses and are associated with most serious influenza epidemics, while Type B infections are usually milder. Rapid diagnosis of influenza A and B has become more important due to the availability of effective antiviral therapy. Rapid diagnosis of influenza can lead to reduced hospital stays, antimicrobial use and cost of hospital care. 1 The Alere BinaxNOW Influenza A & B Card 2 provides a simple, rapid method for the diagnosis of influenza A and B using NP swab and nasal swab specimens. The easy-to-use format and rapid results allow for its use in STAT testing where it can provide information to assist with treatment and hospitalization decisions. 3. Test Principle The Alere BinaxNOW Influenza A & B Card 2 is an immunochromatographic membrane assay that detects influenza type A and B nucleoprotein antigens in respiratory specimens. Influenza specific antibodies and a control antibody are immobilized onto a membrane support as three distinct lines and combined with other reagents/pads to construct a test strip. This test strip is mounted inside a cardboard, book-shaped hinged test card. Swab specimens require a sample preparation step, in which the sample is eluted off the swab into elution solution. Sample is added to the top of the test strip and the test card is closed. Test results will be interpreted at 15 minutes based on the presence or absence of Sample Lines. Alere BinaxNOW Influenza A & B Card 2 test results must be read by the Alere Reader. The Alere Reader is provided separately for result interpretation. The Alere Reader enables direct data entry of User ID, Subject ID, and retention of test results, but is intended for result interpretation only. Note: Depending on the Alere Reader setting selected, the Alere BinaxNOW Influenza A & B Card 2 assay is either immediately inserted in the Alere Reader for automatically timed assay development and result interpretation (Walk Away Mode) or placed on the counter or bench top for manual timed assay development and then placed in the Alere Reader for result interpretation. 4. Specimen Collection/Treatment Use freshly collected specimens for optimal test performance. Inadequate specimen collection or improper sample handling/transport may yield a false-negative result. A. Specimen: Acceptable: Nasopharyngeal Swab Nasal Swab B. Specimen Collection: Nasopharyngeal Swab Use sterile rayon, foam or polyester flexible-shaft NP swabs to collect nasopharyngeal samples. To collect a nasopharyngeal swab sample, carefully insert the swab into the nostril exhibiting the most visible drainage, or the nostril that is most congested if drainage is not visible. Pass the swab directly backwards without tipping the swab head up or down. The nasal passage runs parallel to the floor, not parallel to the bridge of the nose. Using gentle rotation, insert the swab into the anterior nare parallel to the palate advancing the swab into the nasopharynx, leave in place for a few seconds, and then slowly rotate the swab as it is being withdrawn. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 2

To ensure proper collection, the swab should be passed a distance that is halfway of that from the nose to the tip of the ear. This is about half the length of the swab. DO NOT USE FORCE while inserting the swab. The swab should travel smoothly with minimal resistance; if resistance is encountered, withdraw the swab a little bit without taking it out of the nostril. Then elevate the back of the swab and move it forward into the nasopharynx. Nasal Swab For optimal performance, use the swabs provided in the test kit. Alternatively, sterile rayon, foam, polyester or HydraFlock flocked (standard tip) solid shaft swabs can be used to collect nasal swab samples. To collect a nasal swab sample, carefully insert the swab into the nostril exhibiting the most visible drainage, or the nostril that is most congested if drainage is not visible. Using gentle rotation, push the swab until resistance is met at the level of the turbinates (less than one inch into the nostril). Rotate the swab several times against the nasal wall then slowly remove from the nostril. Note: Puritan PurFlock Ultra Flocked Swabs, Copan Regular Flocked Swabs and Calcium Alginate Swabs are not suitable for use in this assay. C. Sample Transport and Storage Samples should be tested as soon as possible after collection. If swab specimens cannot be immediately eluted after collection, the swab is to be returned to its respective sheath and may be stored up to four (4) hours at room temperature. If the swab sample will be held longer than 4 hours, it must be refrigerated at 2-8 C and tested within 24 hours from the time of sample collection. Swab samples eluted in elution solution may be stored refrigerated at 2-8 C and tested within 36 hours from the time of sample collection. Allow all samples to warm to room temperature before testing in the Alere BinaxNOW Influenza A & B Card 2. Swirl gently to mix before testing. D. Handling Precautions Patient samples, controls and test cards should be handled as though they could transmit disease. Observe established precautions against microbial hazards. 5. Reagents and Materials A. Materials Provided Alere BinaxNOW Influenza A & B Card Component Content Quantity Test Cards A cardboard, book-shaped hinged test card containing the test 22 strip Transfer Pipettes Fixed volume (100 µl) transfer pipettes used to transfer sample to 25 the test cards. Positive Control Swab Inactivated influenza A and B viruses dried onto the swab. 1 Negative Control Inactivated Streptococcus Group A dried onto the swab. 1 Swab Elution Solution Vials Vials containing elution solution used to prepare the Swab Specimens and Control Swabs for testing. 22 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 3

Nasal Swabs Sterile swabs for use in the Alere BinaxNOW Influenza A & B Card 2. Product Insert 1 Procedure Card 1 B. Materials Required But Not Provided Alere Reader Calibration Check Card (for use with the Alere Reader) C. Materials Recommended But Not Provided Clock, timer or stopwatch Nasopharyngeal (NP) Swabs 6. Storage and Stability Store kit at 2-30 C. The Alere BinaxNOW Influenza A & B Card 2 kit and reagents are stable until the expiration dates marked on their outer packaging and containers. 7. Quality Control Daily Quality Control: The Alere BinaxNOW Influenza A & B Card 2 has built-in procedural controls. For daily quality control, Alere suggests that you record these controls for each test run. Procedural Controls: An untested card has a blue line at the Control position. If the test flows and the reagents work, this blue line will always turn pink in a tested card. If the blue control line is not present on the test strip before use DO NOT use the test. Discard the test and use another test card from the test kit. The clearing of background color from the result window is a negative background control. The background color in the window should be light pink to white within 15 minutes. External Positive and Negative Controls: Good laboratory practice suggests the use of positive and negative controls to ensure that: Test reagents are working, and The test is correctly performed. Alere BinaxNOW Influenza A & B Card 2 kits contain Influenza A & B Positive and Viral Negative Control Swabs. The Influenza A and B Positive Control swab should generate a positive result for both Influenza A and B when read by the Alere Reader the positive result will be displayed as Passed. 26 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 4

These swabs will monitor the entire assay. Test these swabs with each new shipment received and once for each untrained operator. Other controls may be tested in order to conform with: local, state and/or federal regulations, accrediting groups, and/or, your lab s standard Quality Control procedures. Refer to 42 CFR 493.1256 for guidance on proper QC practices (U.S. customers only). If the correct control results are not obtained, do not report patient results. Contact Technical Service during normal business hours. 8. Precautions 1. For in vitro diagnostic use. 2. Federal Law restricts this device to sale by or on the order of a licensed practitioner. 3. Leave test card sealed in its foil pouch until just before use. 4. When using the Alere Reader, to prevent tearing through the barcode, do not open the foil pouch prior to scanning or entering manually the Test Device ID. 5. Do not use kit past its expiration date. 6. Do not mix components from different kit lots. 7. Do not write on or cover the barcode on the front of the test card prior to inserting into the Alere Reader. 8. The WHITE sample pad at the top of the test strip contains reagents that extract the target antigen from the virus. To ensure optimum performance, add the sample to the TOP HALF of this pad such that all of the sample volume absorbs into the pad. 9. Solutions used to make the control swabs are inactivated using standard methods. However, patient samples, controls, and test cards should be handled as though they could transmit disease. Observe established precautions against microbial hazards. 10. If infection with a novel influenza A virus is suspected based on current clinical and epidemiological screening criteria recommended by public health authorities, specimens should be collected with appropriate infection control precautions for novel virulent influenza viruses and sent to state or local health departments for testing. Viral culture should not be attempted in these cases unless a BSL 3+ facility is available to receive and culture specimens. 2 11. INVALID RESULTS can occur when an insufficient volume of specimen is added to the test cards. To ensure delivery of an adequate volume, make certain that the lower shaft of the transfer pipette is full and does not contain air spaces before dispensing contents of the pipette onto the Sample Pad of the card. If air spaces are present, expel the specimen back into the container by squeezing the top bulb and redraw the specimen into the pipette. Use a new pipette if necessary. 12. All transfer pipettes and elution solution vials are single use items do not use with multiple specimens. 13. Performance characteristics for influenza A were established when influenza A/H3 and A/H1 were the predominant influenza A viruses in circulation. When other influenza A viruses are emerging, performance characteristics may vary. 14. The elution solution packaged in this kit contains saline, detergents and preservatives that will inactivate cells and virus particles. Samples eluted in this solution are not suitable for culture. 15. Elution solution contains Triton X-100 and Proclin 300. Warning: may cause an allergic skin reaction, causes serious eye irritation. 16. Safety data sheets for this product are available upon request. 17. Follow your national, regional, and local ordinances accordingly for waste disposal regulations. 18. Care should be taken when handling the test to avoid potential contamination from debris such as lint, hair and other particulates as these may cause false results. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 5

19. For result interpretation, DO NOT read results visually; results must be read by the Alere Reader. 9. Test Procedure Using the Alere TM Reader WARNING: INVALID RESULTS can occur when too little sample is added to the test. Be sure that the lower part of the transfer pipette is full and does not have any air spaces before you add the sample to the Sample Pad. If there are air spaces, put the sample back into the container by squeezing the top bulb. Redraw the sample from the bottom of the container into the pipette. Use a new pipette if needed. Part 1 Alere TM Reader Set UP 1. Turn on the Alere Reader by pressing the power button. Wait for approximately 10 seconds for the instrument start up sequence. The Alere Reader may be set to two different modes (Walk Away or Read Now). For full instructions on using the Alere Reader please refer to the User Manual and Quick Start Guide. 2. Enter Operator ID by placing Operator ID barcode under scanner or entering manually with the keyboard. Enter Operator Password and confirm by pressing OK. 3. Tap Read Test on the Alere Reader menu, this starts the reading process. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 6

4. Enter Test Device ID by placing the barcode on the foil pouch under scanner or entering manually with the keyboard. 5. Enter Patient ID by placing Patient ID barcode under scanner or entering manually with the keyboard. Note: Default is Patient ID only, see additional options in the Alere TM Reader User Manual. 6. Confirm the data entry of Operator ID, Patient ID and Test Device ID on the screen then tap OK to confirm. Part 2 Test Procedure 7. Alere BinaxNOW Elution Solution vials are prefilled. Twist off the vial cap. 8. Put the swab to be tested in the vial. Rotate the swab three (3) times in the liquid while pushing vigorously against the bottom of the vial. Minimize bubbles. 9. Push the swab against the side of the vial and turn as you remove it from the vial. This removes sample from the swab. Discard the swab into a biohazard waste container. 10. Test the liquid sample (from the test vial) in the Alere BinaxNOW Influenza A & B Card 2 as soon as possible. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 7

11. Remove card from the foil pouch just prior to testing and lay flat on the work bench. 12. Fill pipette by firmly squeezing the top bulb and then placing pipette tip into sample. Slowly release bulb while tip is still in sample. This will pull liquid into the pipette. Make sure there are no air spaces in the lower part of the pipette. Note: To ensure the correct volume of sample is added to the test card, the fixed volume pipette provided in the test kit must be used. 13. See arrow on test card to find the WHITE sample pad at the top of the test strip. Add entire contents of pipette (100 μl) in a continuous flow to the TOP HALF of this pad by squeezing the top bulb such that all of the sample volume absorbs into this pad. DO NOT add sample to the pink/red colored pad. If the sample is added to the incorrect location on the test strip, the test should be discarded. Repeat the test using a new test device and ensure the sample is added to the correct location on the test strip. 14. Peel off adhesive liner from the right edge of the test card. Close and securely seal the card by pressing the right edge of the test card. Part 3 Reading the Results 15a. Read Now Mode: At the 15 minute read time open the Alere Reader drawer, insert the Alere BinaxNOW Influenza A & B Card 2 test into the drawer with the barcode and result window facing up and close the drawer. OR 15b. Walk Away Mode: Once the card is securely 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 8

closed, immediately open the Alere Reader drawer, insert the Alere BinaxNOW Influenza A & B Card 2 test into the drawer with the barcode and result window facing up and close the drawer. The Alere Reader will automatically time the test development and read the result at the read time. 16. WAIT until the result is displayed on the screen. DO NOT OPEN THE DRAWER until Test Results appear on the screen. Note: Do not read test results before or after 15 minutes as they may not be correct. 17. If using a Printer, tap Print to print test results. 18. Open the drawer, remove and discard the used Alere BinaxNOW Influenza A & B Card 2 Test and close the drawer. The Home screen will automatically appear. DO NOT REINSERT TEST DEVICE ONCE A RESULT HAS BEEN OBTAINED. 10. Interpretation of Test Results Results will be automatically displayed on the Alere TM Reader screen. Results will be interpreted as positive or negative for Influenza A and Influenza B in addition to the procedural control line status. Influenza A Positive/ Influenza B Negative Result 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 9

Influenza A Negative/ Influenza B Positive Result Influenza A Negative/ Influenza B Negative Result Invalid Test Result If the test is invalid, another specimen should be collected and tested. 11. Procedure Using the Alere Reader for QC Test Part 1 Alere TM Reader Set UP 1. Turn on the Alere Reader by pressing the power button. Wait for approximately 10 seconds for the instrument start up sequence. The Alere Reader may be set to two different modes (Walk Away or Read Now). For full instructions on using the Alere Reader please refer to Manual and Quick Start Guide. Co-infection Result Co-infection with influenza A and B is very rare. A clinical specimen that generates positive results for both influenza A and B on the Alere BinaxNOW Influenza A & B Card 2 Test should be considered an invalid result and another specimen should be collected and tested. If the test result is again positive for influenza A and B, the specimen should be re-tested by another method prior to reporting the results. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 10

2. Enter Operator ID by placing Operator ID barcode under scanner or entering manually with the keyboard. Enter Operator Password and confirm by pressing OK. 3. Tap Read QC Test on the Alere Reader menu. This starts the reading process. 4. Enter Test Device ID by placing the barcode on the foil pouch under scanner or entering manually with the keyboard. 5. Select the positive or negative control to be tested and tap OK to continue. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 11

6. Confirm the data entry of Operator ID, Test Type, Control Type and Test Device ID on the screen then tap OK to confirm. Part 2 Test Procedure 7. Alere BinaxNOW Elution Solution vials are prefilled. Twist off the vial cap. 8. Put the swab to be tested in the vial. Rotate the swab three (3) times in the liquid while pushing vigorously against the bottom of the vial. Minimize bubbles. 9. Push the swab against the side of the vial and turn as you remove it from the vial. This removes sample from the swab. Discard the swab into a biohazard waste container. 10. Test the liquid sample (from the test vial) in the Alere BinaxNOW Influenza A & B Card 2 as soon as possible. 11. Remove card from the foil pouch just prior to testing and lay flat on the work bench. 12. Fill pipette by firmly squeezing the top bulb and then placing pipette tip into sample. Slowly release bulb while tip is still in sample. This will pull liquid into the pipette. Make sure there are no air spaces in the lower part of the pipette. 13. See arrow on test card to find the WHITE sample pad at the top of the test strip. Add entire contents of pipette (100 μl) in a continuous flow to the TOP HALF of this pad by squeezing the top bulb such that all of the sample volume absorbs into this pad. DO NOT add sample to the pink/red colored pad. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 12

14. Peel off adhesive liner from the right edge of the test card. Close and securely seal the card by pressing the right edge of the test card. Part 3 Reading the Results 15a. Read Now Mode: At the 15 minute read time open the Alere Reader drawer, insert the Alere BinaxNOW Influenza A & B Card 2 test into the drawer with the barcode and result window facing up and close the drawer. OR 15b. Walk Away Mode: Once the card is securely closed, immediately open the Alere Reader drawer, insert the Alere BinaxNOW Influenza A & B Card 2 test into the drawer with the barcode and result window facing up and close the drawer. The Alere Reader will automatically time the test development and read the result at the read time. 16. WAIT until the result is displayed on the screen. DO NOT OPEN THE DRAWER until Test Results appear on the screen. Note: Do not read test results before or after 15 minutes as they may not be correct. 17. If using a Printer, tap Print to print test results. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 13

18. Open drawer, remove and discard the used Alere BinaxNOW Influenza A & B Card 2 Test and close the drawer. The Home screen will automatically appear. DO NOT REINSERT TEST DEVICE ONCE A RESULT HAS BEEN OBTAINED. 12. Limitations 1. A negative test result does not exclude infection with influenza A and/or B. Therefore, the results obtained with the Alere BinaxNOW Influenza A & B Card 2 should be used in conjunction with clinical findings to make an accurate diagnosis. Additional testing is required to differentiate any specific influenza A subtypes, influenza B lineages or influenza strains, in consultation with state or local public health departments. 2. The Alere BinaxNOW Influenza A & B Card 2 detects both viable and non-viable influenza A and B. Test performance depends on antigen load in the specimen and may not correlate with cell culture performed on the same specimen 3. False negative results may occur if a specimen is improperly collected, transported or handled. False negative results may occur if low levels of viruses are present in the specimen. 4. Performance of the Alere BinaxNOW Influenza A & B Card 2 has not been established for monitoring antiviral treatment of influenza. 5. Individuals who have received nasally administered influenza A vaccine may test positive in commercially available influenza rapid diagnostic tests for up to three days after vaccination. 6. The assay performance was established during the 2015 to 2016 influenza season. The positive and negative predictive values may vary depending on the prevalence and population tested. 7. This test has not been evaluated for patients without signs and symptoms of influenza infection. 8. Puritan PurFlock Ultra Flocked Swabs, Copan Regular Flocked Swabs and Calcium Alginate Swabs are not suitable for use in this assay. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 14

13. Expected Values The prevalence of influenza varies from year to year, with outbreaks typically occurring during the fall and winter months. 2 The rate of positivity found in influenza testing is dependent on many factors including the method of specimen collection, the test method used, geographic location, and the disease prevalence in specific localities. In the Alere BinaxNOW Influenza A & B Card 2 multi center prospective clinical study (described in the Clinical Study section below), a total of 585 nasal or nasopharyngeal swab specimens were determined to be evaluable. The number and percentage of influenza A and influenza B positive cases per specified age group, as determined by the Alere BinaxNOW Influenza A & B Card 2 assay, are presented in the two tables below: Influenza A Positives by the Alere BinaxNOW Influenza A & B Card 2 Assay with the Alere TM Reader per Age Group Age Group Prospective Clinical Study During the 2015/2016 Influenza Season Number of Nasal or Nasopharyngeal Swab Specimens Number of Influenza A Positives Influenza A Positivity Rate <1 year 39 3 7.7% 1 to 5 year 119 23 19.3% 6 to 10 years 91 17 18.7% 11 to 15 years 39 10 25.6% 16 to 21 years 32 8 25.0% 21 to 60 years 228 65 28.5% 60 years 37 10 27.0% Total 585 136 23.2% Influenza B Positives by the Alere BinaxNOW Influenza A & B Card 2 Assay with the Alere TM Reader per Age Group Age Group Prospective Clinical Study During the 2015/2016 Influenza Season Number of Nasal or Nasopharyngeal Swab Specimens Number of Influenza B Positives Influenza B Positivity Rate <1 year 39 1 2.6% 1 to 5 year 119 7 5.9% 6 to 10 years 91 15 16.5% 11 to 15 years 39 4 10.25% 16 to 21 years 32 7 21.8% 21 to 60 years 228 15 6.6% 60 years 37 5 13.5%% Total 585 54 9.2% 14. Performance Characteristics Clinical Study Clinical performance characteristics of Alere BinaxNOW Influenza A & B Card 2 with the Alere TM Reader were evaluated in a multi-site prospective study during the 2015-2016 flu season in the U.S. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 15

A total of twelve (12) investigational sites throughout the U.S. participated in the study. To be enrolled in the study, patients had to be presenting at the participating study centers with flu-like symptoms. Either two nasopharyngeal swabs or two nasal swabs were collected from one nostril from each patient with flu-like symptoms using standard collection methods and tested using the Alere BinaxNOW Influenza A & B Card 2 assay with the Alere TM Reader. An FDA cleared influenza realtime Polymerase Chain Reaction (RT-PCR) assay was utilized as the comparator method for this study. At all sites, one nasal or nasopharyngeal swab was eluted in elution solution and the other swab was eluted in 1 ml of Viral Transport Media (VTM). The swab eluted in elution solution was tested on Alere BinaxNOW Influenza A & B Card 2, according to product instructions. All twelve (12) sites shipped the VTM sample to a central testing laboratory for RT-PCR. External control testing, using Alere BinaxNOW Influenza A & B Card 2 Positive and Negative Controls, was performed prior to sample testing each day, at all study sites. A total of 645 Subjects were enrolled in this study. Of those, 60 swab samples did not meet eligibility criteria due to protocol deviations (sample handling or storage errors or Subject withdrawal). A total of 585 nasal or nasopharyngeal swab specimens were considered evaluable. Patient age and gender distribution for all the evaluable specimens is presented in the table below. Age and Gender Distribution Age Group Female Male <1 year 18 21 1 to 5 years 57 62 6 to 10 years 45 46 11 to 15 years 21 18 16 to 21 years 18 14 21 to 60 years 143 85 60 years 25 12 Total 327 258 Of the evaluable 585 specimens, Alere BinaxNOW Influenza A & B Card 2 generated invalid results with the Alere Reader for 20 specimens, resulting in a total of 565 specimens for performance analysis. Compared to the comparator method, the performance of Alere BinaxNOW Influenza A & B Card 2 with the Alere TM Reader for influenza A and influenza B are presented in the two tables below. Influenza A Performance with Alere BinaxNOW Influenza A & B Card 2 with the Alere TM Reader Against the Comparator Method Alere BinaxNOW Comparator Method Influenza A & B Card 2 Flu A Positive Negative Total Positive 113 23 136 Negative 21 408 429 Total 134 431 565 Sensitivity: 84.3% (113/134) (95%CI: 77.2% - 89.5%) Specificity: 94.7% (408/431) (95%CI: 92.1% - 96.4%) 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 16

Influenza B Performance with Alere BinaxNOW Influenza A & B Card 2 with the Alere TM Reader Against the Comparator Method Alere BinaxNOW Comparator Method Influenza A & B Card 2 Flu B Positive Negative Total Positive 51 3 54 Negative 6 505 511 Total 57 508 565 Sensitivity: 89.5% (51/57) (95%CI: 78.9% - 95.1%) Specificity: 99.4% (505/508) (95%CI: 98.3% - 99.8%) During the prospective clinical study, the invalid rate was 3.4% (20/585) (95% CI: 2.2% to 5.2%). The invalid rate includes 19 results that were positive for both influenza A and B. Analytical Studies Reproducibility A reproducibility study of Alere BinaxNOW Influenza A & B Card 2 with the Alere TM Reader was conducted by operators from three (3) sites using panels of blind coded specimens containing negative, high negative (below the limit of detection), low positive (at the limit of detection), and moderate positive (above the limit of detection) influenza A and B viral samples. Virus dilutions were prepared using one influenza A strain and one influenza B strain in Viral Transport Media (VTM). The concentrations of the viral stocks (in TCID50/mL) were determined by standard virologic method prior to inactivation by the vendors. Contrived nasal swab specimens were prepared by coating 10 microliters of each virus dilution onto the swab. The contrived swab samples were tested according to product instructions and all results were interpreted with the Alere Reader. Participants tested the sample panels over five (5) different days. The percent agreement with expected results, across the three sites, for the influenza A moderate positive, low positive, and high negative samples were 100% (90/90), 100% (90/90) and 96.6% (86/89), respectively. The percent agreement with expected result for the influenza B moderate positive, low positive, and high negative samples were 100% (90/90), 100% (89/89) and 97.8% (88/90), respectively. All of the true negative samples (90) generated negative test results. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 17

Site-To-Site Qualitative Results Percent Agreement with Expected Results Sample Type Site 1 Site 2 Site 3 Overall % Agreement with Expected Results Moderate Positive 100% (30/30) 100% (30/30) 100% (30/30) 100% (90/90) Influenza A Low 100% 100% 100% 100% Positive (30/30) (30/30) (30/30) (90/90) High Negative 100% 96.7% 96.6% (29/29) 1 (28/30) (29/30) (86/89) Moderate Positive 100% (30/30) 100% (30/30) 100% (30/30) 100% (90/90) Influenza B Low 100% 100% 100% 100% Positive (30/30) (30/30) (29/29) 2 (89/89) High Negative 100% (30/30) 93.3% (28/30) 100% (30/30) 97.8% (88/90) True Negative 100% (30/30) 100% (30/30) 100% (30/30) 100% (90/90) 1 One sample generated an invalid results and was not re-tested. 2 One sample generated a positive Flu A and Flu B result, was considered invalid and was not re-tested. There were no significant differences observed within run (replicates tested by one operator) between run (five different days), between sites (three sites), or between operators (six operators). Analytical Sensitivity (Limit of Detection) Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader limit of detection (LOD) was determined by evaluating different concentrations of five (5) strains of influenza A and three (3) strains of influenza B virus. Pre-screened negative natural nasal swab specimens were eluted in 1 X PBS. Swab elutes were combined and mixed thoroughly to create a clinical matrix pool to be used as the diluent. Each influenza virus strain was diluted in this natural nasal swab matrix pool to generate virus dilutions for testing. The vendor provided virus strains were re-titered and the concentrations (in TCID50/mL) were determined by standard virologic method. Contrived nasal swab samples were prepared by coating 10 microliters of each virus dilution onto the swab. The contrived swab samples were tested after elution in elution solution according to the test procedure. The LOD for each influenza strain tested was determined as the lowest virus concentration that was detected 95% of the time (i.e., concentration at which at least 19 out of 20 replicates tested positive). The confirmed LODs in natural nasal swab matrix for each influenza strain tested are presented in the table below: 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 18

Limit of Detection (LOD) Study Results Strain Concentration TCID 50 /ml % Detected A/Anhui/13 (H7N9) Inactivated* 1:1500 95% A/Indiana/10/11 (H3N2v) 3.67 x 10 1 95% A/California/7/2009 (H1N1) 5.94 x 10 3 95% A/Perth/16/2009 (H3N2) 1.68 x 10 4 95% A/Puerto Rico/8/34 (H1N1) 3.16 x 10 4 95% B/Massachusetts/02/12 (Yamagata) 1.47 x 10 6 95% B/Nevada/03/2011 (Victoria) 9.72 x 10 3 95% B/Malaysia/2506/2004 4.27 x 10 3 95% Note: 10μl of each virus dilution was coated onto a swab. * The LOD is reported as a dilution factor from the inactivated stock. The concentration of the virus stock prior to inactivation was 10 10.9 EID 50 /ml. Analytical Reactivity An analytical reactivity (inclusivity) study was performed to determine whether the Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader is able to detect a variety of influenza A and B strains that represent temporal and geographic diversity. Vendor provided stocks of influenza A and influenza B were diluted in elution solution to generate virus dilutions for testing. The virus strains were re-titered and the concentrations (in TCID50/mL) were determined by standard virologic methods. Contrived swab samples were prepared by coating 10 microliters of virus dilution onto each swab. The contrived swab samples were tested according to the test procedure. The starting dilution concentration selected for testing in this study was of a high concentration in order to generate a strong positive result. Each starting dilution per virus strain was tested in triplicates initially. If the initial testing concentration tested positive for all three replicates, the strain was further diluted 10-fold and tested in triplicates until at least one out of three replicates generated a negative result. When a negative result was obtained, additional 2-fold dilutions were tested, starting from the highest dilution that produced 100% (3/3) positive results. The Alere BinaxNOW Influenza A & B Card 2 assay detected all strains tested (3/3) at the concentrations indicated in the table below. Analytical Reactivity Study Results Influenza Strain Influenza A Subtype or Concentration Influenza B Genetic Lineage TCID 50 /ml A/Brisbane/59/2007 A/H1N1 8.35 x 10 1 A/California/4/2009 A/H1N1 (pdm) 3.68 x 10 3 A/Maryland/04/2011 A/H1N1 (pdm) 1.07 x 10 2 A/New Caledonia/20/1999 A/H1N1 2.08 x 10 2 A/New Jersey/8/1976 A/H1N1 1.04 x 10 1 A/New York/18/2009 A/H1N1 (pdm) 1.41 x 10 2 A/Solomon Islands/3/2006 A/H1N1 5.28 x 10 1 A/WSN/33 A/H1N1 5.00 x 10 2 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 19

A/Texas/018/2014 A/H1N1 7.90 x 10 3 A/Texas/002/2014 A/H1N1 1.70 x 10 3 A/Aichi/2/68 H3N2 7.90 x 10 3 A/Brisbane/10/2007 H3N2 3.68 x 10 0 A/Hong Kong/8/68 H3N2 2.41 x 10 1 A/Port Chalmers/1/73 H3N2 1.58 x 10 4 A/Texas/50/2012 H3N2 1.06 x 10 0 A/Victoria/3/75 H3N2 1.58 x 10 5 A/Victoria/361/2011 H3N2 2.11 x 10 0 A/Wisconsin/67/2005 H3N2 2.63 x 10 1 B/Bangladesh/3333/2007 Yamagata Lineage 2.11 x 10 5 B/Brisbane/60/2008 Victoria Lineage 3.41 x 10 5 B/Florida/04/2006 Yamagata Lineage 2.97 x 10 5 1B/Lee/40 Victoria Lineage 6.81 x 10 3 B/Maryland/1/59 Yamagata Lineage 7.90 x 10 4 B/Montana/05/2012 Victoria Lineage 2.51 x 10 6 B/Ohio/1/2005 Victoria Lineage 3.40 x 10 3 B/Russia/69 Yamagata Lineage 5.93 x 10 5 B/Texas/06/2011 Yamagata Lineage 1.47 x 10 6 B/Victoria/304/2006 Victoria Lineage 1.58 x 10 5 B/Victoria/504/2000 Victoria Lineage 6.81 x 10 4 B/Wisconsin/01/2010 Yamagata Lineage 1.45 x 10 4 Annual Analytical Reactivity An annual review of the Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader performance was conducted by testing contemporary strains of human influenza virus supplied by the CDC. The viral stocks were diluted in elution solution to generate virus dilutions for testing. Contrived swab samples were prepared by coating 50μl of the virus dilution onto each swab. The contrived swab samples were tested according to the test procedure. For each viral strain included in the panel, all dilutions were tested until a level that produced 100% negative results for two consecutive dilutions on all 5 replicates at each level was obtained. Annual analytical reactivity testing data can be found at: www.alere.com/en/home/productsservices/infectious/influenza.html Analytical Specificity (Cross-Reactivity) To determine the analytical specificity of Alere BinaxNOW Influenza A & B Card 2 with the Alere TM Reader, 58 commensal and pathogenic microorganisms 58 commensal and pathogenic microorganisms (41 bacteria, 16 viruses and 1 yeast) that may be present in the nasal cavity or nasopharynx were tested, with results read by the Alere Reader. All of the following microorganisms were negative when tested at concentrations ranging from 10 3 to 10 10 cells/ml or CFU/mL (bacteria), 10 4 to 10 8 TCID50/mL or CEID50/mL (viruses), and 10 8 cells/ml (yeast). 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 20

Bacteria Viruses Yeast Acinetobacter calcoaceticus Adenovirus type 1 Candida albicans Bacteroides fragilis Adenovirus type 7 Bordetella pertussis Cytomegalovirus 6 Chlamydia pneumonia Human Coronavirus OC43 Corynebacterium diptheriae Human Coronavirus 229E 6 Enterococcus faecalis Enterovirus/Coxsackievirus B4 Escherichia coli Human Cytomegalovirus strain AD-169 6 Gardnerella vaginalis Human metapneumovirus Haemophilus influenza Rhinovirus type 1A Haemophilus parainfluenza Measles virus, strain Edmonston Klebsiella pneumonia Mumps virus, strain Enders Lactobacillus casei Parainfluenza virus 1 Lactobacillus plantarum Parainfluenza virus 2 Legionella pneumophilia Parainfluenza virus 3 Listeria monocytogenes 1 Respiratory Syncytial virus, type B, strain 18537 Moraxella/Branhamella catarrhalis Epstein Barr virus, strain P-3 Mycobacterium avium Mycobacterium intracellulare Mycobacterium tuberculosis Mycoplasma pneumoniae 5 Neisseria gonorrhoeae Neisseria meningitides Neisseria mucosa 2 Neisseria sicca 3 Neisseria subflava Peptostreptococcus anaerobius Proteus mirabilis Proteus vulgaris Pseudomonas aeruginosa Serratia marcescens 4 Staphylococcus aureus Staphylococcus epidermidis Streptococcus mutans Streptococcus pneumoniae Streptococcus salivarius Streptococcus sanguinis Streptococcus Group A Streptococcus sp. Gp. B Streptococcus sp. Gp. C Streptococcus sp. Gp. F Streptococcus sp. Gp. G 1 Flu A positive result obtained at 7.23 x 10 9 cells/ml; concentration diluted to 7.23 x 10 8 cells/ml and generated a negative result. 2 Flu A positive result obtained at 9.4 x 10 9 cells/ml; concentration diluted to 9.4 x 10 8 cells/ml and generated a negative result. 3 Flu A positive result obtained at 1.0 x 10 10 cells/ml; concentration diluted to 1.0 x 10 9 cells/ml and generated a negative result. 4 Flu A positive result obtained at 6.5 x 10 8 cells/ml; concentration diluted to 6.5 x 10 7 cells/ml and generated a negative result. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 21

5 Mycoplasma pneumonia 10 3 was the maximum cfu/ml that could be achieved for growth. 6 Viruses were tested at concentrations lower than the recommended 10 5 pfu/ml, reflect the stock concentration received from the vendor. Viral stocks were tested at the highest achievable titer allowed by the vendor stock concentration. Interfering Substances The following substances, naturally present in respiratory specimens or that may be artificially introduced into the nasal cavity or nasopharynx, were evaluated with Alere BinaxNOW Influenza A & B Card 2 with the Alere TM Reader at the concentrations listed below and were found not to affect test performance. Substance Mucin Whole Blood Sinus Buster Nasal Spray NeoSynephrine Cold & Sinus Extra Strength Spray Zicam Extreme Congestion Relief 4-acetamidophenol Acetylsalicylic acid (aspirin) Albuterol Chlorpheniramine Dexamethasone Dextromethorphan Diphenhydramine Doxylamine Succinate Ephedrine Flunisolide Guaiacol glycerol ether (pseudoephedrine) Mupirocin Oxymetazoline Phenylephrine Relenza Rebetol Rimantadine Tamiflu Tobramycin Triamcinolone Concentration 2% (w/v) 1% (v/v) 20% (v/v) 20% (v/v) 20% (v/v) 203 μg/ml 652 μg/ml 399 ng/ml 142 ng/ml 0.8 mg/ml 1 μg/ml 5 μg/ml 232 ng/ml 276 ng/ml 6.8 ng/ml 3.58 ng/ml 12 mg/ml 0.6 mg/ml 12 mg/ml 284 ng/ml 4.4 μg/ml 0.28 ng/ml 1.102 μg/ml 2.4 mg/ml 40 μg/ml Inhibition by other Microorganisms Alere BinaxNOW Influenza A & B Card 2 with the Alere TM Reader test performance in the presence of non-influenza respiratory pathogens was evaluated. Vendor provided stocks of influenza A and B strains were diluted in clinical contrived matrix to approximately 2 times the limit of detection. Contrived influenza A and B positive swab specimens were prepared by coating 10 microliters of virus dilution onto each swab. The following non-influenza viruses were tested (3/3) at the concentration provided in the table below and were found not to affect test performance. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 22

Virus Panel Concentration (TCID 50 /ml) Adenovirus Type 1 4.51 x 10 5 Rhinovirus Type 1A 4.51 x 10 6 Respiratory Syncytial Virus, Type B, Strain 18537 2.54 x 10 4 Inhibition by High Levels of Influenza A and B Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader test performance in the presence of high levels of influenza A and B was evaluated. Vendor provided stocks of influenza A and B strains were diluted in clinical contrived matrix to approximately 2 and 20 times the limit of detection. Contrived influenza A and B positive swab specimens were prepared by coating 10 microliters of virus dilution onto each swab. To create the co-infection swabs, diluted influenza A (at a concentration approximately 20 times the LoD) was added to the near LoD Flu B swab. Likewise, diluted influenza B (at a concentration approximately 20 times the LoD) was added to the near LoD Flu A swab. No impact on test performance was observed. CLIA Waiver Studies As part of the prospective study testing nasopharyngeal or nasal swabs eluted in elution solution (as described in the Performance Characteristics section above) the accuracy of Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader was evaluated when used by operators who had no laboratory experience and who were representative of CLIA waived testing sites (intended users). The study was conducted at twelve (12) CLIA waived sites with 36 intended users participating. No training on the use of the test was provided to the operators. A total of 642 Subjects were enrolled in this study. Of those, 33 swab samples did not meet eligibility criteria due to protocol deviations (sample handling or storage errors or Subject withdrawal). A total of 609 nasal or nasopharyngeal swab specimens were considered evaluable. The prospectively collected samples, described above were supplemented with testing swab samples prepared with archived respiratory specimens that were obtained from patients with influenza-like symptoms and were confirmed positive or negative by an FDA cleared assay for influenza A and influenza B. A total of 105 swabs (65 swabs positive for influenza B, 20 swabs positive for influenza A and 20 swabs negative for both influenza A and influenza B) were tested. The supplemental samples were blind-coded and randomized and the testing was incorporated into the daily workflow at each testing site. Overall, 714 swab specimens were tested by intended users at CLIA waived sites with Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader, and the results were compared to the an FDA cleared molecular-based comparator method. Of the evaluable 714 specimens, Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader generated invalid results for 21 specimens, resulting in a total of 693 specimens for performance evaluation. The positive percent agreement (PPA) and the negative percent agreement (NPA) between the Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader and the comparator method, for all specimens combined, are presented in the tables below, including the 95% confidence intervals (95% CI). 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 23

Influenza A Performance with Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader Against the Comparator Method Alere BinaxNOW Comparator Method Influenza A & B Card 2 Flu A Positive Negative Total Positive 141 23 164 Negative 21 508 529 Total 162 531 693 PPA: 87.0% (141/162) (95%CI: 81.0% - 91.4%) NPA: 95.7% (508/531) (95%CI: 93.6% - 97.1%) Influenza B Performance with Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader Against the Comparator Method Alere BinaxNOW Comparator Method Influenza A & B Card 2 Flu B Positive Negative Total Positive 116 3 119 Negative 6 568 574 Total 122 571 693 PPA: 95.1% (116/122) (95%CI: 89.7% - 97.7%) NPA: 99.5% (568/571) (95%CI: 98.5% - 99.8%) During this study, the invalid rate was 2.9% (21/714) (95% CI: 1.9% to 4.5%). The invalid rate includes 19 results that were positive for both influenza A and B. Sample Studies with Near the Limit of Detection A study was conducted to evaluate the performance of Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader weakly reactive samples when used by untrained users. Randomized blind-coded panels, containing negative, low positive (targeted at the limit of detection {LOD} or assay cutoff), and high negative (below the LOD) influenza A and influenza B specimens, were tested with Alere BinaxNOW Influenza A & B Card 2 at three (3) CLIA waived sites (300 tests in total). Six untrained users at the CLIA waived sites participated in the study. The panel testing was conducted over a minimum of 16 days, and the testing was integrated into the users daily work flow. The performance of Alere BinaxNOW Influenza A & B Card 2 with samples near the assay cutoff in the hands of untrained users is shown below. Influenza A and B Testing of Samples near the Assay Cutoff (LOD) Untrained Users Sample Type % Detection 95% CI Flu A Low Positive (near LOD) 96.7% (58/60) 88.6%, 99.1% Flu B Low Positive (near LOD) 100.0% (60/60) 94.0%, 100% Flu A High Negative (below LOD) 1 100.0% (60/60) 94.0%, 100% Flu B High Negative (below LOD) 1 96.7% (58/60) 88.6%, 99.1% True Negative 1 100.0% (60/60) 94.0%, 100% 1 Percent Detection correlates to the detection of negative results. 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 24

Using risk analysis as a guide, flex studies were conducted on Alere BinaxNOW Influenza A & B Card 2 with the Alere Reader. The testing evaluated numerous sources of potential human errors and environmental factors that could affect the accuracy of results, including those related to sample handling, reagent handling, extremes of operational conditions, and the operation of the Alere Reader. The studies demonstrated that the test and the Alere Reader are robust to the usage variation and environmental factors that may be encountered. 15. References 1. Williams, KM, Jackson MA, Hamilton M. Rapid Diagnostic Testing for URIs in Children: Impact on Physician Decision Making and Cost. Infect. Med. 19(3): 109-111, 2002. 2. Updated Interim Guidance for Laboratory Testing of Persons with Suspected Infection with Avian Influenza A (H5N1) Virus in the United States CDC Health Alert, June 7, 2006. http://www.phppo.cdc.gov/han/archivesys/viewmsgv.asp?alertnum=00246 Symbols Ordering and Contact Information Reorder numbers: 575-000: Alere BinaxNOW Influenza A & B Card 2 (22 Tests) 575-080: Alere BinaxNOW Influenza A & B Card 2 Control Swab Kit Technical Support Advice Line Further information can be obtained from your distributor, or by contacting Technical Support on: US + 1 855 731 2288 ts.scr@alere.com Africa, Russia, CIS +972 8 9429 683 ARCISproductsupport@alere.com Asia Pacific +61 7 3363 7711 APproductsupport@alere.com Canada +1 800 818 8335 CANproductsupport@alere.com Europe & Middle East +44 161 483 9032 EMEproductsupport@alere.com Latin America +57 2 6618797 LAproductsupport@alere.com 120003980 Rev.2 07/18 BinaxNOW Influenza A & B Card 2 with the Alere TM Reader CLSI + More Packet 25