ReCap Product Rationale

Similar documents
FLH /11

Scan Bi-Polar 22/28. Operative Technique

Optimum implant geometry

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

Optimum implant geometry

Vanguard. Total Knee System

Instrumentation Options

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

The Leader in Orthopaedic Innovation

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Optimum implant geometry

Featuring. Technology. Product Rationale

Bone Preservation Stem

INSTRUMENTS. Product Rationale

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Reaching new heights. Comprehensive. Efficient. Simple.

TOTAL HIP REPLACEMENT:

PLR. Proximal Loading Revision Hip System

G7 ACETABULAR SYSTEM. beautifully. efficient.

A bone preserving solution... to help recapture a patient s way of life.

Design Rationale. ECHELON Primary Hip System

Bi-Polar 22.2mm & 28mm System - Operative technique

Active Articulation E1

operative technique Kent Hip

Dual Articular.

Answer. Hip System Design Features:

Common Instruments for Biomet Hip Systems

Metasul LDH Large Diameter Head

Arcos Modular Femoral Revision System

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

INSTRUMENTS. Design Rationale

WHAT IS THE BEST BONE FIXATION TYPE? 2/11/2011

Optimizing function Maximizing survivorship Accelerating recovery

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

Comprehensive Reverse Shoulder System

Efficacy Innovation ABG II. Brochure. Surgical Protocol. Cemented Stem

DOWNLOAD OR READ : TECHNIQUES IN REVISION HIP AND KNEE ARTHROPLASTY PDF EBOOK EPUB MOBI

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Manza Cup HA SURGICAL TECHNIQUE.

Understanding Hip Implant Options

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

PROCOTYL E Acetabular Cup System. Modular to Fit Patient s Anatomy. Versatile for Revisions.

Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Hip Resurfacing System

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

Bone Bangalore

Positioning Sleeve Surgical Technique

Revision Modular Stem type RMD

Clinical Evaluation Surgical Technique

Approach Patients with Confidence

Cementless femoral stem type SF

ACETABULAR CUP SURGICAL TECHNIQUE

Surface Arthroplasty Risk Index

One system for all revision types

Oxford. Partial Knee

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

LPS SYSTEM POCKET GUIDE

Approach Patients with Confidence

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

Informed Consent for HRA

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

Restoration Modular Revision Hip System. Choice Matters

Surgical procedure. METS Modular Proximal Femur

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

DIRECT ANTERIOR APPROACH

S U R G I C A L T E C H N I Q U E

Product Rationale. Where Strength and Modularity Connect

RECOVERY. P r o t r u s i o

The information contained in this document is intended for healthcare professionals only.

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Specifications guide ECHELON. Hip System

RECLAIM REVISION HIP SYSTEM

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

Allofit /Allofit -S Alloclassic Acetabular Cup System

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Continuing the Tradition. VerSys Heritage Hip System

Consistency in U2 Knee System over Time

Vanguard Complete Knee System

Progeny Hip Stem. Surgical Protocol and Product Specifications

Hip Product Brochure

The information contained in this document is intended for healthcare professionals only.

PINNACLE REVISION CUP SYSTEM

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Integra. Titan Modular Shoulder System, 2.5

Sulzer Orthopedics Joint & Fracture Care

Integral 180 Surgical Technique

CONSENSUS ORTHOPEDICS INC.

Hip Implants. Hip Implants. 6 Your partner for implants and trauma products. Euromed Implants GmbH General Catalogue

Surgical procedure. METS Coned Hemi-Pelvis

SURGICAL TECHNIQUE. Entrada Hip Stem

MetaFix Cementless Total Hip Replacement Product overview

Vario-Cup Prosthesis System & Large Heads

Peggers Super Summaries: THR and Revision Concepts

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

Transcription:

ReCap Product Rationale

A Complete resurfacing system designe engineering principles, tried and tested m clinically proven fixation methods Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel. +44 (0)1656 655221 Fax. +44 (0)1656 645454

d on sound aterials and Bone Preservation Optimal wear Characteristics/Tribology Clinically Proven Fixation Methods Intra-operative Flexibility Precise & Reproducible Instrumentation

Anti Rotational Fins - Additional primary fixation 3mm Wall Thickness - Greater bone preservation Porous Plasma Spray (PPS) - Twice the rotational stability of beads and clinically proven as a bone friendly in-growth surface (HA Coated Options) Oversized Shell Options (2mm) - Allowing for femoral and acetabular mismatch Hemispherical Shell Design Large Implant Range - 12 Shell sizes (44mm 66mm in 2 mm increments) Introduction Accumulated experience has shown that wear particles of polyethylene are the principle cause of interface failure. This is particularly important in young, high activity individuals where long term fixation is needed. The time has come when the use of optimally designed Metal on Metal bearings, with virtually no generation of wear debris, should be considered in such patients. Biomet s commitment to manufacturing Gold Standard Metal on Metal implants date back to 1961, with Stanmore Total Hip System. This was followed by the McKee Farrah Total Hip System and more recently with the M 2 a Hip System. In response to this, Biomet, along with Key Development Centres world-wide, have developed the ReCap Total Resurfacing System.

The ReCap System M2a Precision Manufacture - 100 % checked by Zigo Machine 23 degrees Head Coverage - Allowing greater range of motion Unique Internal Spherical Geometry - Allowing for more natural femoral loading patterns. Interlok Surface - Clinically proven cemented surface Large Implant Range - 12 sizes (38mm-60mm) 2mm Increments Bone Preservation The ReCap Total Resurfacing System resects minimal bone, both from the femur and acetabulum. This is attributed to the thin components and 2mm increment component sizing. The unique spherical femoral reaming technique employed by the system, offers some distinct advantages: The acetabular component follows the same philosophy. With a wall thickness of only 3mm and again a 2mm increment component sizing, it allows minimal reaming to achieve optimal fixation. Reduces Risk of Notching Normal Femoral Loading Restoration of Normal Anatomy Reduced Risk of Dislocation

Optimal Wear Characteristics and Tribology Biomet had a vast understanding of what is needed to produce the optimal Metal on Metal Implant, focusing efforts on optimal materials, manufacturing tolerances and processes. As-cast materials were determined to have greater abrasive wear resistance when compared to single or multiple heat treated materials A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty, J. Cawley, J.E.P. Metcalf, A.H. Jones, T.J. Band and D.S. Skupien, Wear 255 (2003), 999-1006 6

Clinically Proven Fixation Methods In determining which implant and surface coating is best for patients, many issues should be considered, including: How are initial stability and fixation achieved? To what degree will osseointegration occur, and when? Will the coating successfully inhibit debris migration? By addressing these three critical issues, Biomet s Porous Plasma Spray has achieved outstanding clinical results since its introduction in1981. At Follow up, surgeons are observing results of nearly 100% survivorship at over 10 years with implants such as the Bimetric Hip System, Taperloc Hip System, AGC Total Knee System and Bio-Modular Total Shoulder System.It is well documented that Hydroxyapatite stimulates Osteoblast activity and will further aid in initial stability when applied on top of our clinically proven porous plasma spray. 99.5% Survivorship 12 years 1 100% Survivorship 10.4 years 2 99.6% Survivorship 12 years 3 98% Survivorship 12 Years 4 7

[ ] As-cast materials were determined to have greater abrasive wear resistance when compared to single or multiple heat treated materials Intra-operative Flexibility In an unpredictable situation like surgery, it is comforting to know you have a number of options to deal with difficult situations. ReCap is one of the most comprehensive systems on the market, offering: Large Implant Range 38mm-60mm Femoral Head 2mm Increments 44mm-66mm Acetabular Cup 2mm Increments 2mm Oversized Acetabular Cups Oversized outer diameter allows for femoral and acetabular size mismatching Porous Coating & HA Coating Femoral and acetabular components available as cemented or uncemented with HA 8 Modular Revision Heads Designed for easy revision to THR Can be used with any Biomet Stem

Precise & Reproducible Instrumentation Dedicated Instrumentation Machined to exact tolerances enabling reproducible results time after time Sequential Surgical Technique Logical stepped surgical procedure giving the surgeon intra operative flexibility Designed to be used with MicroPlasty Instruments designed to be used through a minimal incision, allowing Rapid Recovery for the Patient 9

Ordering Information Implants ReCap Resurfacing Heads ReCap Magnum Porous Coated Acetabular Component Cat. No. Description 157238 ReCap Resurfacing Head Sz 38mm 157240 ReCap Resurfacing Head Sz 40mm 157242 ReCap Resurfacing Head Sz 42mm 157244 ReCap Resurfacing Head Sz 44mm 157246 ReCap Resurfacing Head Sz 46mm 157248 ReCap Resurfacing Head Sz 48mm 157250 ReCap Resurfacing Head Sz 50mm 157252 ReCap Resurfacing Head Sz 52mm 157254 ReCap Resurfacing Head Sz 54mm 157256 ReCap Resurfacing Head Sz 56mm 157258 ReCap Resurfacing Head Sz 58mm 157260 ReCap Resurfacing Head Sz 60mm Cat. No. Description 157844 ReCap PF PC Acetabular Comp Ø 44/38mm 157846 ReCap PF PC Acetabular Comp Ø 46/40mm 157848 ReCap PF PC Acetabular Comp Ø 48/42mm 157850 ReCap PF PC Acetabular Comp Ø 50/44mm 157852 ReCap PF PC Acetabular Comp Ø 52/46mm 157854 ReCap PF PC Acetabular Comp Ø 54/48mm 157856 ReCap PF PC Acetabular Comp Ø 56/50mm 157858 ReCap PF PC Acetabular Comp Ø 58/52mm 157860 ReCap PF PC Acetabular Comp Ø 60/54mm 157862 ReCap PF PC Acetabular Comp Ø 62/56mm 157864 ReCap PF PC Acetabular Comp Ø 64/58mm 157866 ReCap PF PC Acetabular Comp Ø 66/60mm M2a-Magnum Modular Heads Cat. No. Description 157438 M2a Magnum Modular Head Sz 38mm 157440 M2a Magnum Modular Head Sz 40mm 157442 M2a Magnum Modular Head Sz 42mm 157444 M2a Magnum Modular Head Sz 44mm 157446 M2a Magnum Modular Head Sz 46mm 157448 M2a Magnum Modular Head Sz 48mm 157450 M2a Magnum Modular Head Sz 50mm 157452 M2a Magnum Modular Head Sz 52mm 157454 M2a Magnum Modular Head Sz 54mm 157456 M2a Magnum Modular Head Sz 56mm 157458 M2a Magnum Modular Head Sz 58mm 157460 M2a Magnum Modular Head Sz 60mm ReCap Magnum HA Porous Coated Acetabular Component Cat. No. Description 157944 ReCap PF HA/PC Acetabular Comp Ø 44/38mm 157946 ReCap PF HA/PC Acetabular Comp Ø 46/40mm 157948 ReCap PF HA/PC Acetabular Comp Ø 48/42mm 157950 ReCap PF HA/PC Acetabular Comp Ø 50/44mm 157952 ReCap PF HA/PC Acetabular Comp Ø 52/46mm 157954 ReCap PF HA/PC Acetabular Comp Ø 54/48mm 157956 ReCap PF HA/PC Acetabular Comp Ø 56/50mm 157958 ReCap PF HA/PC Acetabular Comp Ø 58/52mm 157960 ReCap PF HA/PC Acetabular Comp Ø 60/54mm 157962 ReCap PF HA/PC Acetabular Comp Ø 62/56mm 157964 ReCap PF HA/PC Acetabular Comp Ø 64/58mm 157966 ReCap PF HA/PC Acetabular Comp Ø 66/60mm M2a-Magnum Modular Head Type1 Taper Adaptors Cat. No. Description 130818 ReCap Tpr Adptr 38-40mm 6mm (T1) 130819 ReCap Tpr Adptr 38-40mm 3mm (T1) 130820 ReCap Tpr Adptr 38-40mm STD (T1) 130821 ReCap Tpr Adptr 38-40mm +3mm (T1) 130822 ReCap Tpr Adptr 38-40mm +6mm (T1) 130823 ReCap Tpr Adptr 38-40mm +9mm (T1) 139252 ReCap Tpr Adptr 42-50mm 6mm (T1) 139254 ReCap Tpr Adptr 42-50mm 3mm (T1) 139256 ReCap Tpr Adptr 42-50mm STD (T1) 139258 ReCap Tpr Adptr 42-50mm +3mm (T1) 139260 ReCap Tpr Adptr 42-50mm +6mm (T1) 139262 ReCap Tpr Adptr 42-50mm +9mm (T1) 139264 ReCap Tpr Adptr 52-60mm 6mm (T1) 139266 ReCap Tpr Adptr 52-60mm 3mm (T1) 139268 ReCap Tpr Adptr 52-60mm STD (T1) 139270 ReCap Tpr Adptr 52-60mm +3mm (T1) 139272 ReCap Tpr Adptr 52-60mm +6mm (T1) 139274 ReCap Tpr Adptr 52-60mm +9mm (T1) M2a-Magnum Modular Head 12/14 Taper Adaptors Cat. No. Descriptioners 130824 ReCap Tpr Adptr 38-40mm 2mm (12/14) 130825 ReCap Tpr Adptr 38-40mm STD (12/14) 130826 ReCap Tpr Adptr 38-40mm +4mm (12/14) 130827 ReCap Tpr Adptr 38-40mm +8mm (12/14) 130829 ReCap Tpr Adptr 42-50mm 2mm (12/14) 130830 ReCap Tpr Adptr 42-50mm STD (12/14) 130831 ReCap Tpr Adptr 42-50mm +4mm (12/14) 130832 ReCap Tpr Adptr 42-50mm +8mm (12/14) 130834 ReCap Tpr Adptr 52-60mm 2mm (12/14) 130835 ReCap Tpr Adptr 52-60mm STD (12/14) 130836 ReCap Tpr Adptr 52-60mm +4mm (12/14) 130837 ReCap Tpr Adptr 52-60mm +8mm (12/14) 10

Instrumentation ReCap Femoral Instrument Tray Catalogue Number 31-600206 ReCap General Instrument Tray Catalogue Number 31-600201 ReCap Cylindrical Reamer Tray Catalogue Number 31-600203 ReCap Spherical Reamer Tray Catalogue Number 31-600204 ReCap Acetabular Instruments Tray Catalogue Number 31-600202 ReCap Acetabular Grater Reamer Tray Catalogue Number 31-600055 ReCap / Magnum Mod Hd General Case Catalogue Number 31-600199 (note: when ordering catalogue no. 31-600199 please also order either 31-600386 or 31-600388) Additional Items Required ReCap / Magnum Mod Head Trial Taper Adaptor Set (12-14) Catalogue Number 31-600388 ReCap / Magnum Mod Hd Trial Taper Adaptor Set (T1) Catalogue Number 31-600386

FLH 155 10/05 Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel. +44 (0)1656 655221 Fax. +44 (0)1656 645454