Int J Clin Exp Med 2017;10(1): /ISSN: /IJCEM

Similar documents
COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES

Comparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the Distal End Radius

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

Surgical Management of Distal end Radius Fractures by Various Methods: A Prospective Study

Int J Clin Exp Med 2016;9(5): /ISSN: /IJCEM

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

Injury, Int. J. Care Injured 42 (2011) Contents lists available at ScienceDirect. Injury. journal homepage:

Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates

Clinical Study Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

Non-comminuted extra-articular fractures of distal radius treated with Percutaneous pinning

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures

The functional importance of malunion in distal radius fractures

Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report

Operative Treatment of Intra-articular Distal Radius Fractures Using the Small AO External Fixation Device

Prospective Randomised Study of Intra-Articular Fractures of the Distal Radius: Comparison Between External Fixation and Plate Fixation

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Do Radiographic parameters predict Functional Outcome in Distal end Radius Fracture?

JMSCR Vol 05 Issue 04 Page April 2017

Emile N. Brown, MD, and Scott D. Lifchez, MD

Distal radius fractures raises considerable interest and

Management of intra-articular fractures of distal end radius in adults

ORIGINAL ARTICLE. possible. Accurate assessment of standard radiographs is essential for appropriate 3. management. And includes true posterior- 4

JMSCR Vol 05 Issue 06 Page June 2017

A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES

Fractures of distal end of Radius: A study on fracture reduction and stable fixation

Treatment of unstable distal radius fractures with the volar locking plate

Operative Indications

Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius

The value of manipulation of displaced distal radius fractures in the emergency department

A prospective study of surgical management of distal radius fracture in adult with plate fixation

Intra articular distal radius fractures and volar plate fixation: a prospective study

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬

UZZAMAN KS 1, AWAL KA 2, ALAM MK 3

Disclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant

Therapeutic Effects of Volar Anatomical Plates Versus Locking Plates for Volar Barton s Fractures

Functional Outcome of Displaced Extraarticular Distal Radius Fracture by Kapandji Intrafocal Fixation

Comparison between Distractor Application on Both Radial & Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture

University of Groningen. Fracture of the distal radius Oskam, Jacob

Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate

Acute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture

Acomparison of percutaneous and pin-and-plaster techniques in distal radius fracture

Crossed Steinmann Pin Fixation In Supracondylar Femur Fractures In Adults A Case Series

Abstract INTRODUCTION. Martin Vlček 1 *, Edib Jaganjac 1, Jan Pech 1, David Jonáš 1, Radek Kebrle 2

Outcome following distally locked volar plating for distal radius fractures with metadiaphyseal involvement

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Review Article Comparison of conservative and operative treatment for distal radius fracture: a meta-analysis of randomized controlled trials

Factors Predicting Late Collapse of Distal Radius Fractures

INTERNAL FIXATION OF THE METACARPALS AND PHALANGES P. BURGE

VOLAR LOCKING COMPRESSION SYSTEM DISTAL AND RADIUS FRACTURE DISSERTATION

Incidence 643,000 per year United States 15% of all fractures, peak occurrence age 60 70, Classification - AO/OTA (Murray 2013)

Functional Outcome in Distal Radius Fractures Treated with Locking Compression Plate

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

ORIGINAL PAPER. Department of Hand Surgery, Nagoya University School of Medicine ABSTRACT

University of Groningen. Fracture of the distal radius Oskam, Jacob

The Outcome of Intra-Articular Distal Radius Fractures Treated With Fragment-Specific Fixation

IS CASTING AN ACCEPTABLE TREATMENT APPROACH FOR A DISTAL RADIUS FRACTURE THAT HAS UNDERGONE A SATISFACTORY CLOSED REDUCTION?

ROLE OF LOCKING COMPRESSION PLATES IN THE TREATMENT OF FRACTURES DISTAL END OF RADIUS

Evaluation of volar locking plate fixation for management of intraarticular fractures of distal end of radius

Paresh Patil, Kiran Gaonkar, Adish Patil, Nishant Gaonkar, Ketan Gupta*, Nirav Patel, Himanshu Kulkarni

The effect of an associated ulnar styloid fracture on the outcome after fixation of a fracture of the distal radius

Hand Stiffness Following Distal Radius Fractures

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

DVR Crosslock Distal Radius Plating System. Product Brochure

UNFAVORABLE RESULTS AND degenerative arthritis. Arthroscopically Guided Osteotomy for Management of Intra-Articular Distal Radius Malunions

Disclosures. Epidemiology 10/12/2015. Distal Radius Fractures: Staying Out of Trouble

Comparison between Intramedullary Nailing and Percutaneous K-Wire Fixation for Fractures in the Distal Third of the Metacarpal Bone

Common Limb Fractures. Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009

Type III Supracondylar Fractures of the Humerus in Children Straight-Arm Treatment

Hardware-Related Complications After Dorsal Plating for Displaced Distal Radius Fractures

EVIDENCE BASED MEDICINE. Pennig Dynamic Wrist Fixator

Redisplacement of Distal Radius Fracture after Initial Closed Reduction: Analysis of Prognostic Factors

Kousuke Iba 1*, Yasuhiro Ozasa 1, Takuro Wada 1, Tomoaki Kamiya 1, Toshihiko Yamashita 1, Mitsuhiro Aoki 2. Abstract

Long-term Results of Dorsally Displaced Distal Radius Fractures Treated With the Pi-Plate: Is Hardware Removal Necessary?

Surgical correction for supination loss following malunited radial fractures

Evaluation of instability factors in distal radius fractures

journal ORIGINAL RESEARCH

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Distal Radius Fractures Using Acu-Loc Volar Plate

DISTAL RADIUS FRACTURES: LONG TERM FUNCTIONAL AND RADIOLOGICAL RESULTS OF PERCUTANEOUS PINNING FIXATION

Conservative treatment of the distal radius fracture using thermoplastic splint: pilot study results

Distal radius fracture Golden standard and breaking news

Reproducibility of Three Dimensional Digital Preoperative Planning for the Osteosynthesis of Distal Radius Fractures

Fractures of the distal radius have occupied a storied history

Union Surgical. T-Pin. Fixation System for Distal Radius & Distal Ulna Fractures. Surgical Technique

Historical Perspective of Distal Radius Fracture Classifications in the Twentieth Century

Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

D-RAD SMART PACK Plating System. A series of case studies

FUNCTIONAL AND RADIOLOGICAL OUTCOMES AFTER VOLAR LOCKING PLATE FIXATION IN TYPE C DISTAL RADIUS FRACTURES A RETROSPECTIVE STUDY

Use of Cobra External Fixator for treatment of Distal Radius Fractures

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

University of Groningen. Fracture of the distal radius Oskam, Jacob

Additional Ulno-Radial Pinning for Prevention of Metaphyseal Collapse in Distal Radius Fracture: A Comparative Study

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

Juxta-articular Plate Fixation in Distal Radius Intra-articular Fractures with Accompanying Volar Free Fragments beyond the Watershed Line

Transcription:

Int J Clin Exp Med 2017;10(1):1139-1144 www.ijcem.com /ISSN:1940-5901/IJCEM0040515 Original Article Comparison of open reduction volar locking plate fixation and closed reduction percutaneous K-wire fixation in the treatment of AO type C1 distal radius fractures Hüseyin Yetkin 1, Taşkın Altay 2, Fırat Ozan 3, Cemil Kayalı 2, Şemmi Koyuncu 4 1 Department of Orthopedics and Traumatology, Bandırma State Hospital, Balıkesir, Turkey; 2 Department of Orthopedics and Traumatology, İzmir Bozyaka Training and Research Hospital, İzmir, Turkey; 3 Department of Orthopedics and Traumatology, Kayseri Training and Research Hospital, Kayseri, Turkey; 4 Department of Orthopedics and Traumatology, Bayburt State Hospital, Bayburt, Turkey Received September 23, 2016; Accepted October 28, 2016; Epub January 15, 2017; Published January 30, 2017 Abstract: Objective: We aimed to compare both functional and radiological outcomes of AO classification type C1 distal radial fractures managed using volar locking plates and percutaneous K-wire fixation. Materials and methods: In total, 15 patients were included in group 1, in which open reduction and internal fixation using volar locking plates were performed, whereas 15 patients were included in group 2, in which closed reduction and percutaneous K-wire fixation were utilized. In both groups, the functional outcomes were evaluated according to the Gartland-Werley scoring system. The Knirk and Jupiter scoring system was used to classify arthritic changes. Stewart s radiological assessment criteria were used in angular assessments. Grip strength measurement was performed. Results: At the end of the follow-up, a significant difference was detected between the groups in volar tilt value (P<0.05) but not in radial inclination and radial length (P>0.05). Significant differences were detected in the Gartland-Werley score and the mean Knirk and Jupiter score between the two groups (P<0.05). No significant difference was found in the mean Stewart score between the groups (P>0.05). Conclusion: It was concluded that K-wire fixation seems insufficient in distal radius fractures of the complex intra-articular type. Keywords: Distal radius fractures, volar locking plates, pinning, K-wires, intra-articular fractures Introduction Distal radius fracture is the most commonly encountered fracture of the upper extremity [1-3]. In management, the primary goal is to restore the anatomical integrity and function of the joint [4]. Simple stable fracture patterns are best treated with a period of immobilisation [1, 5]. However, there is no established treatment method for unstable fractures [1, 3, 5]. There are numerous surgical options for the management of distal radial fractures, which include the use of percutaneous K-wire fixation, external fixation and open reduction internal fixation with volar and dorsal plates, both locking and non-locking [2, 5, 6]. Two commonly used methods of fixation are open reduction with internal fixation using plates and percutaneous pin fixation [1, 2, 7]. K-wire fixation allows for simple, rapid, minimally invasive and low-cost fixation of fractures [1, 3, 5]. K-wire fixation cannot protect against radial collapse in osteoporotic bone as K-wires are not load-bearing devices [2, 5]. Internal fixation provides fixation while allowing early active movement; however, it requires maximal softtissue dissection [8-11]. Volar locking plates are also biomechanically superior, with an implant stiffness that will support the physiological load placed on the wrist joint [2, 8-11]. Studies have reported tendon problems despite carefully performed internal fixation [1, 5, 8-11]. In this study, we aimed to compare both the functional and radiological outcomes of AO

Table 1. Demographic characteristics and clinical outcomes classification type C1 intra-articular distal radial fractures managed by open reduction and internal fixation using volar locking plates with closed reduction and percutaneous K-wire fixation. Materials and methods Group 1 () We retrospectively evaluated 30 patients who underwent surgical treatment due to AO type C1 distal radial fractures between 2008 and 2012. Patients were separated into two groups according to surgical technique. In total, 15 patients (11 males, 4 females; 6 right, 9 left; mean age 50 years; range 34-67 years) were included in group 1, in which open reduction and internal fixation using volar locking plates was employed, whereas 15 patients (8 males, Group 2 () P Value Mean age, years, (range) 50 (34-67) 45 (18-77) 0.350 Sex Female 4 7 0.256 Male 11 8 AO classification C1 15 15 Side of involvement Right 6 8 0.464 Left 9 7 Dominant extremity injury 12 13 0.718 Followup, months 17.5 (12-50) 18.1 (12-38) 0.418 Time from injury to surgery, days, (range) 2.87 (1-7) 2.6 (0-9) 0.781 Mean length of hospitalisation, days 5.33 (2-8) 4.4 (1-11) 0.104 Table 2. Functional outcomes of two techniques [mean (range)] Group 1 Group 2 P value Grip strength (kg) 46 (25-60) 44 (10-55) 0.748 Flexion ( ) 73 (65-80) 72 (60-80) 0.704 Extension ( ) 76 (70-80) 74 (60-80) 0.462 Pronation ( ) 88 (85-90) 86 (60-90) 0.830 Supination ( ) 87 (75-90) 86 (50-90) 0.979 Ulnar deviation ( ) 31 (25-40) 30 (15-40) 0.795 Radial deviation ( ) 26 (20-30) 25 (15-30) 0.877 Gartland-Werley score 1.2 (0-3) 2.8 (0-10) 0.042 Abbreviations: kg, kilogram. In radiological assessments, radial inclination, volar tilt and radial length were measured in a comparative manner with a contralateral side. The system described by Knirk and Jupiter was used to classify arthritic changes [13], whereas Stewart s radiological assessment criteria were used in angular assessments [14]. Wrist range of motion (ROM) was measured using a standard goniometer. The grip strength measurement was performed using a standard Jamar dynamometer (Sammsons Preston Inc. Bolingbrook, IL, USA, 60440-4989). Statistical analysis All statistical analyses were performed in SPSS version 19.0 (IBM, Chicago, IL, USA). The Kolmogorov-Smirnov test was used to assess the normality of data, whereas the Levene s test was used to assess the homogeneity of quantitative data. Among groups, an independent sample t-test was used for binary comparisons of parametric variables, whereas the Mann-Whitney U test was used for non-parametric variables. Pearson s chi-square test was used to compare categorical variables. P<0.05 was considered to indicate a statistically significant result. Ethics statement 7 females; 8 right, 7 left; mean age 45 years; range 18-77 years) were included in group 2, in which closed reduction and percutaneous K-wire fixation was the method used. Demographic characteristics were recorded for all patients. In both groups, functional outcomes after treatment were rated according to the Gartland-Werley clinical scoring system [12]. The protocol was reviewed and approved by the institutional review board of İzmir Bozyaka Training and Research Hospital, İzmir, Turkey (No. 25.04.2012/8-4). Written informed consent was obtained from all participating patients. 1140 Int J Clin Exp Med 2017;10(1):1139-1144

Table 3. Radiographic outcomes of two techniques Group 1 Group 2 P value Radial inclination ( ) 22.5 (15-31) 23.5 (14-32) 0.57 Volar tilt ( ) +7.1 (-4 to +11) 1.62 (-10 to +17) 0.038 Radial length (mm) 9.2 (3-15) 8.09 (3-13) 0.339 Mean Knirkand Jupiter score 0.2 (0-1) 0.67 (0-1) 0.011 Stewart score 0.53 (0-4) 1 (0-3) 0.092 Figure 1. Comparative radiographs (with contralateral site) of patient with AO type C1 distal radius fracture of the left side. A, B. Images taken during the preoperative period. C, D. Images taken at month 15 postoperatively. 18.1 months (range, 12-38) in groups 1 and 2, respectively (P=0.418). The mean length of hospitalisation was 5.33 (range, 2-8) and 4.40 (range, 1-11) days in groups 1 and 2, respectively (P=0.104). Table 2 presents functional outcomes in each of the participant groups. Grip strength measured at the involved and contralateral sites was 46 ± 0.04 kg and 62 ± 0.04 kg in group 1, respectively (P=0.008), and 44 ± 0.06 and 61 ± 0.06 kg in group 2, respectively (P=0.043). No significant difference was detected between the groups when the grip strength values obtained at the final control visit postoperatively were compared (P=0.748). Results The patient characteristics and clinical outcomes are presented in Table 1. In cases of trauma, hand trauma was dominant in 12 (80%) and 13 (86.6%) of the patients in group 1 and group 2, respectively. The causes of injury in the study population were as follows: traffic accident in 3 patients (10%), fall from height in 5 patients (16.6%), occupational injury in 1 patient (3.3%) and simple fall in 21 patients (70%). The mean time from injury to surgery was 2.87 days (range, 1-7) in group 1 and 2.6 days (0-9) in group 2 (P=0.781). The mean duration of follow up was 17.5 months (range, 12-50) and In group 1, the radiological values measured at the involved and contralateral sites were as follows: radial inclination 22.5 ± 1.07 and 24.5 ± 0.74 (P=0.132); volar tilt 7.15 ± 1.21 and 9.4 ± 0.64 (P=0.114); and radial length 9.2 ± 0.9 mm and 10.9 ± 0.5 mm (P=0.396), respectively. In group 2, radiological values measured at the involved and contralateral site were as follows: radial inclination 23.5 ± 1.3 and 24.4 ± 0.5 (P=0.520); volar tilt 1.62 ± 2.23 and 11.29 ± 0.29 (P=0.001); and radial length 8.09 ± 0.7 mm and 9.83 ± 0.6 mm (P=0.79), respectively. In the final control visit postoperatively, a significant difference was detected between groups in the volar tilt value (P=0.038) but not in the radial inclination (P=0.57) or radial length (P=0.339) (Table 3). The mean ROM values at final follow-up in group 1 and 2 were 73 ± 0.95 (range, 65-80) and 72 ± 1.3 (range, 60-80) for flexion angles (P=0.704); 76.3 ± 1.4 (range, 70-80) and 74.6 ± 1.5 (range, 60-80) for extension angles (P=0.462); 87 ± 1.1 (range, 75-90) and 86 ± 1141 Int J Clin Exp Med 2017;10(1):1139-1144

Figure 2. Comparative radiographs (with contralateral site) of patient with AO type C1 distal radius fracture of the left side. A, B. Images taken during the preoperative period. C, D. Early postoperative period. E, F. Images taken at month 14 postoperatively. 2.6 (range, 50-90) for supination angles (P=0.979); 88.6 ± 0.5 (range, 85-80) and 86.6 ± 2.0 (range, 60-90) for pronation angles (P=0.830); 31.6 ± 1.35 (range, 25-40) and 30.6 ± 1.5 (range, 15-40) for ulnar deviation angles (P=0.795); and 26.0 ± 1.1 (range, 20-30) and 25.6 ± 1.1 (range, 15-30) for radial deviation angles (P=0.877), respectively. The Gartland-Werley score was found to be 1.2 ± 0.3 (range, 0-3) in the group that underwent volar locking plate fixation. The outcome was found to be excellent in 11 patients (73.3%) and good in 4 patients (26.7%). The Gartland- Werley score was 2.8 ± 2.1 (range, 0-10) in the group that underwent K-wire fixation. The outcome was found to be excellent in seven patients (46.6%), good in seven patients (46.6%) and moderate in one patient (6.8%). A significant difference was detected in the Gartland-Werley score between groups (P= 0.042). The mean Knirkand Jupiter score was 0.2 ± 0.1 (range, 0-1) and 0.67 ± 0.1 (range, 0-1) days in groups 1 and 2, respectively (P=0.011). Stewart s score was 0.53 ± 0.29 (range, 0-4) in the group that underwent volar locking plate fixation. The outcome was found to be excellent in 11 patients (73.3%), good in 3 patients (20%) and moderate in 1 patient (6.8%). Stewart s score was 1.0 ± 0.2 (range, 0-3) in the group that underwent K-wire fixation. The outcome was found to be excellent in 6 patients (40%) and good in 9 patients (60%). No significant difference was found in the mean Stewart score between groups (P=0.092) (Figures 1 and 2). 1142 Int J Clin Exp Med 2017;10(1):1139-1144

Discussion Numerous conservative and operative methods have been described for the treatment of distal radial fractures [1-7]. The primary goal in all methods of treatment is the restoration of the joint with maximum recovery of function [1, 4]. Although many studies have presented the results of surgical methods, limited studies have compared managed percutaneous pinning with locked plate fixation in the treatment of complex intra-articular fracture types, such asdistal radial fractures [1, 2, 7, 15]. In our study, there were significantly more volar tilt losses and arthritic changes at the end of follow-up in patients who underwent K-wire fixation. In addition, there was no significant difference in ROM between the groups; however, it was found that functional outcomes differed significantly between methods. Distal radius fractures classified as AO type C are treated with a surgical approach because of unstable structures. Locking plates are used widely and offer successful outcomes at the distal radius [1, 5, 8-11]. The technique is effective in the provision of anatomical alignment and allows early mobilization of the joint due to its higher durability in fixation [1, 5, 8-11]. Its biomechanical advantages include the ability to insert screws in different planes and close implementation to the articular surface. Therefore, locking plates are frequently preferred in osteoporotic or comminuted fractures [6, 8-11]. A lower incidence of flexor and extensor tendon problems due to fixation that is more compatible with the surrounding tissues is an advantage of volar locking plate interventions [8-11]. Nevertheless, tendon problems and loss of alignment at the articular surface and inflammation in tissues surrounding the fixation material can develop despite meticulous procedures [5, 8-11]. Percutaneous K-wire fixation allows for lowcost fixation of unstable fractures with biological osteosynthesis as a less invasive procedure [3, 5, 16]. In addition, K-wire fixation allows for a shorter operation time, ease of hardware removal and excellent cosmetic outcomes [1, 2, 16]. However, this type of fixation is not rigid [1, 5]. K-wire fixation may not be sufficient to provide anatomical continuity in displaced, comminuted fractures [1, 2, 5]. Loss of fixation, pin-site infection and injury in the sensorial branch of the radial nerve are additional complications reported in K-wire fixation [3]. However, the total number of complications is lower in volar locking plate when compared with K-wire fixation [3]. In our study, no complications were observed in either group. Although K-wire is a feasible and inexpensive method for simple fractures, locking plate seems to be appropriate for complicated fractures, especially when closed reduction is not possible [7]. More recently, in a study in which radiographic and functional outcomes were compared in patients with distal radius fractures who underwent volar locking plate or K-wire fixation, Brennan et al. reported that functional outcomes in volar locking plate werenot superior to those of K-wire, although good results were achieved by volar locking plate [17]. In a study, comparing K-wire and volar locking plate fixation in intra-articular distal radius fracture, Hull et al. reported that there was no difference in terms of outcome measures for all patients, rated using either the PRWE scores or DASH scores [1]. In a study with a 26-month follow-up comparing K-wire and volar locking plate in patients aged 60 years or older, it was reported that the Gartland-Werley and Castaing scores did not reveal any significant differences between the groups. However, there was a significantly earlier return to activities of daily living in the volar plate group [15]. In a randomized study comparing K-wire and volar locking plate fixation, no difference in functional outcome was reported in patient wrist evaluation in the 12 months after Kirschner wire fixation versus volar locking plate fixation. Kirschner wire fixation was less costly and faster to perform [7]. In conclusion, it could be concluded that K-wire fixation seem insufficient in distal radius fractures of the complex intra-articular type due to higher volar tilt loss and more arthritic changes during the postoperative period when compared with volar locking plate, in addition to significant differences in functional outcomes, as rated by the Gartland-Werley score between these methods. 1143 Int J Clin Exp Med 2017;10(1):1139-1144

Disclosure of conflict of interest None. Address correspondence to: Dr. Hüseyin Yetkin, Department of Orthopedics and Traumatology, Bandırma State Hospital, Çanakkale Yolu 6. Kilometre, Bandırma, Balıkesir, Turkey. Tel: +90 266 738 00 22; Fax: +90 266 738 00 13; E-mail: hy.yetkin@ gmail.com References [1] Hull P, Baraza N, Gohil M,Whalley H, Mauffrey C, Brewster M, Costa ML. Volar locking plates versus K-wire fixation of dorsally displaced distal radius fractures--a functional outcome study. J Trauma 2011; 70: 125-128. [2] Knox J, Ambrose H, McCallister W, Trumble T. Percutaneous pins versus volar plates for unstable distal radius fractures: a biomechanic study using a cadaver model. J Hand Surg 2007; 32: 813-817. [3] Chaudhry H, Kleinlugtenbelt YV, Mundi R, Ristevski B, Goslings JC, Bhandari M. Are volar locking plates superior to percutaneous K-wires for distal radius fractures? A metaanalysis. Clin Orthop Relat Res 2015; 473: 3017-3027. [4] Oshige T, Sakai A, Zenke Y, Moritani S, Nakamura T. A comparative study of clinical and radiological outcomes of dorsally angulated, unstable distal Radius fractures in elderly patients: intrafocal pinning versus volar locking plating. J Hand Surg 2007; 32: 1385-1392. [5] McFadyen I, Field J, McCann P, Ward J, Nicol S, Curwen C. Should unstableextra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial. Injury 2011; 42: 162-116. [6] Shyamalan G, Theokli C, Pearse Y, Tennent D. Volar locking plates versuskirschner wires for distal radial fractures-a cost analysis study. Injury 2009; 40: 1279-1281. [7] Costa ML, Achten J, Parsons NR, Rangan A, Tubeuf S, Yu G, Lamb SE. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults withdorsally displaced fracture of distal radius: randomised controlled trial. BMJ 2014; 2349. [8] Letsch R, Infanger M, Schmidt J, Kock HJ. Surgical treatment of fractures of the distalradius with plates: a comparison of palmar and dorsalplateposition. Arch Orthop Trauma Surg 2003; 123: 333-339. [9] Arora R, Lutz M, Fritz D, Zimmermann R, Oberladstätter J, Gabl M. Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures. Arch Orthop Trauma Surg 2005; 125: 399-404. [10] Orbay JL, Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 2006; 445: 58-67. [11] Murakami K, Abe Y, Takahashi K. Surgical treatment of unstable distal Radius fractures with volar locking plates. J Orthop Sci 2007; 12: 134-140. [12] Gartland JJ, Werley CW. Evaluation of healed Colles fractures. J Bone Joint Surg Am 1951; 33: 895-907. [13] Knirk JL, Jupiter JB. Intra-articular fractures of the distal end of the radius in young adults. J Bone Joint Surg 1986; 68: 647-659. [14] Stewart HD, Innes AR, Burke FD. Functional cast-bracing for Colles fractures. A comparison between cast-bracing and conventional plaster casts. J Bone Joint Surg Br 1984; 66: 749-753. [15] Voigt C, Lill H. What advantages does volar plate fixation have over K-wire fixation for distal radius extension fractures in the elderly? Unfallchirurg 2006; 109: 845-854. [16] Günay C, Öken ÖF, Yavuz OY, Günay SH, Atalar H. Which modality is the bestchoice in distalradius fractures treated with two different Kirschner wire fixation and immobilization techniques? Ulus Travma Acil Cerrahi Derg 2015; 21: 119-126. [17] Brennan SA, Kiernan C, Beecher S, O Reilly RT, Devitt BM, Kearns SR, O Sullivan ME. Volar plate versus k-wire fixation of distal radius fractures. Injury 2016; 47: 372-376. 1144 Int J Clin Exp Med 2017;10(1):1139-1144