The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

Similar documents
The effect of light source distance on diametral tensile strength of nano particle composite

EFFECT OF CURING LIGHT DISTANCE ON MICROLEAKAGE AND COMPRESSIVE STRENGTH OF PEDIATRIC COMPOSITE RESTORATIONS

Effect of Small Starfruit (Averrhoa bilimbi L.) Extract Gel On Tooth Enamel Color Changes

Effect of turmeric tamarind solution on surface roughness of conventional glass ionomer cement

Effect of whitening toothpaste on the discoloration level of stained conventional glass ionomer cement

Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post

MDJ Comparative evaluation of compressive strength Vol.:14 No.:1 2017

Bond strength test of acrylic artificial teeth with prosthetic base

Effect of Thickness and Recycling on Transverse Strength of Relined Acrylic Resin Denture

Opacity and Color Changes of Light-Cured Ideal Makoo (IDM)

Original Research. The Effect of temperature on the strength of luting cements Patil SG et al

Effect of cross infection control barriers used on the light-curing device tips on the cure depth of a resin composite

Influence of the light curing unit and thickness of residual dentin on generation of heat during composite photoactivation

Evaluation the Effect of Different Surface Treatment on Shear Bond Strength between Composite Increments (An in vitro study)

Review Article Effect of Recurring Procedure on the Surface Micro hardness Values of Different Composite Resins

GAETANO PAOLONE DIRECT POSTERIORS CUSTOM SHIELD PART 2

Effect of betel leaf extract gel on the hardness of enamel

The Method of Manufacturing Nonmetallic Test- Blocks on Different Sensitivity Classes

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

Evaluation of Bond Strength of Silicone and Acrylic Resin Based Resilient Denture Liners Over A Period of Storage in Water.

Bond strengths between composite resin and auto cure glass ionomer cement using the co-cure technique

WHY PLASMA TECHNOLOGY?

The Influence of Temperature on the Efficacy of Polymerization of Composite Resin

SDR has proven reliability in high C-factor cavities 2

The Sof-Lex Finishing and Polishing System 3ESPE

Effects of Different Temperatures and Storage Time on the Degree of Conversion and Microhardness of Resin-based Composites

Effectiveness of Second-generation Light-emitting Diode (LED) Light Curing Units

Ketac Universal Aplicap

Curing Effectiveness of Bulkfill Composites

Effect of light curing units on physical properties of composites

QUARTZ SPLINT. Our fiber expertise is your strength TM.

November Copyright DENTSPLY International

shrink less than 1 %

Evaluation of a Second-Generation LED Curing Light

A Step-by-Step Approach to

Efficacy of New LED Light-Curing Units in Hardening of Class II Composite Restorations

Effect of ethanol in mouthwashes On the surface hardness of a dental resin composite material

Effect of Reduced Exposure Times on the Microhardness of Nanocomposites Polymerized by QTH and Second-generation LED Curing Lights

OUR EXPERIENCE WITH GRADIA DIRECT IN THE RESTORATION OF ANTERIOR TEETH

The Influence of Some Dentin Primers on Calcium Hydroxide Lining Cement

Effect of application of betel leaf extract gel on enamel surface roughness

Evaluation of Curing Light Distance on Resin Composite Microhardness and Polymerization

An evaluation of the hardness of flexible Denture Base Resins

Vickers Hardness of Composite Resins Cured with LED and QTH Units

In nitro bond strength of cements to treated teeth

For the Perfect Class V and All Cervical Area Gingival Margins when Placing Direct Composites, Create an Injection Molding Matrix

Natural beauty restored.

Effects of miswak and nano calcium carbonate toothpastes on the hardness of demineralized human tooth surfaces

Peak. Universal Bond Light Cure Adhesive with Chlorhexidine. With its versatile formulation, Peak Universal Bond is the only adhesive you need.

MDJ The Effect of Pepsi Cola Beverage on Surface Roughness Vol.:7 No.:1 2010

EQUIA Forte Glass Hybrid Restorative System. For long term posterior restorations

Light Conduction Capability of Different Light-Transmitting FRC Posts

One solution for all. cavity classes. Tetric Evo product line. Tetric EvoCeram. Tetric EvoFlow. Tetric EvoCeram Bulk Fill Tetric EvoFlow Bulk Fill

Hybrid Ceramics Block for CAD/CAM Use Shades: A2, A3, A3.5

SCIENTIFIC INFORMATION

Amaris. You want outstanding esthetic restorations with the WOW-EFFECT

Contamination of Composite Resin by Glove Powder and Saliva Contaminants: Impact on Mechanical Properties and Incremental Layer Debonding

Get in front of the 8 ball with the new Fuji VIII GP. The first auto-cure, resin reinforced glass ionomer restorative

Continually Fluoride Releasing Aesthetic Dental Restorative Material

Natural beauty restored.

ADHESIVE RECONSTRUCTION IN HELP OF THE ORTHODONTIC TREATMENT

< 1% shrinkage! * new record: Low Shrink Posterior Restorative. volumetric. The fi rst direct posterior composite to achieve less than 1 % shrinkage.

AvaDent Bonding Procedure Results: The AvaDent bond exceeds ADA requirements.

Transdental Photo-activation Technique: Hardness and Marginal Adaptation of Composite Restorations Using Different Light Sources

Comparison of shear bond strength of aesthetic restorative materials

Effect of light irradiation distance during intermediate. polymerization on depth of cure and hardness of. indirect composite

F i l t e k Z550. Nano Hybrid Universal Restorative. Technical Data Sheet

Surface changes of enamel after brushing with charcoal toothpaste

Preparation of experimental dental alginate impression material from Sargassum spp. seaweed extract based on its setting time

Tensile bond strength of four denture resins to porcelain teeth with different surface treatment

Evaluation of Shear Bond Strength Orthodontic Bracket and Adhesive Remaining Materials on the Enamel Surface Using ARI (Adhesive Remnant Index)

shrink less than 1 %

TOOTH SELECTION & ARRANGEMENT IN REMOVABLRE PARTIAL DENTURE

Finite Element Analysis of Shear Versus Torsion Adhesive Strength Tests for Dental Resin Composites

Evaluation of bond to Enigma High Impact Denture Base

Effects of layering technique on the shade of resin overlays and the microhardness of dual cure resin cement

Indian Journal of Basic & Applied Medical Research; June 2012: Issue-3, Vol.-1, P

G-CEM LinkAce. The new strength in self-adhesive cement

Curious Curing. How do you know if you re getting the right output from your LCU? 50 JULY 2016 // dentaltown.com

DENT211-FIXED PROSTHODONTICS Page 1 Lecture: High Strength Ceramics INTRODUCTION

Effect of cavity preparation design on the fracture resistance of directly and indirectly restored premolars

IJopRD INTRODUCTION ABSTRACT MATERIALS AND METHODS /jp-journals

Tizian Blank. Tizian Zirconia Reinforced Composite

Fuji II LC. A Perfect Choice

Clinical report. Drs Paul and Alexandre MIARA and F. CONNOLLY COMPOSITE POSTERIOR FILLINGS. How to control. layering? 8 - Dentoscope n 124

A real leader takes you further.

Bonding to dentine: How it works. The future of restorative dentistry

A real leader takes you further.

EQUIA. Self-Adhesive, Bulk Fill, Rapid Restorative System

Marketed in US as: Individual Attention Only

The effect of light curing units, curing time, and veneering materials on resin cement microhardness y

Effect of Shade and Thickness of Porcelain Veneers on Depth of Cure of Light-Cured Resin-Based Luting Cement

Direct composite restorations for large posterior cavities extended range of applications for high-performance materials

Filling materials are used to replace missing parts of the tooth.

REINFORCED COMPOSITE BLOC FOR PERMANENT RESTORATION. BRILLIANT Crios. High performance made brilliant

Australian Dental Journal

Discover. the power of fibres. everx Posterior. from GC. sub-structure. Extending the limits. The strongest composite. of direct restorations.

Charisma Topaz PRODUCT INFORMATION. The three - in - one composite solution. Heraeus Kulzer Nordic AB

Handling efficiency of autopolymerized resin applied using the brush-on technique

Transcription:

Journal of Physics: Conference Series PAPER OPEN ACCESS The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin To cite this article: R H F Zaini et al 2018 J. Phys.: Conf. Ser. 1073 042008 View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 13/12/2018 at 18:38

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin R H F Zaini 1, A Soufyan 1, B Irawan 1 * and M Damiyanti 1 1 Department of Dental Materials, Faculty of Dentistry, Universitas Indonesia, Jakarta, 10430, Indonesia *E-mail: bisosro15@yahoo.co.id Abstract. A method to control infection when using a light-emitting diode (LED) curing unit (LCU) is to wrap it in a transparent plastic barrier (cling wrap). The influence of a plasticwrapped LCU and curing distance variances on diametral tensile strength of composite resin was evaluated. A total of 60 disc-shaped specimens were formed and cured using plasticwrapped and unwrapped LCUs. The specimens were divided into six groups with curing distances of 0.5 to 5 mm. The diametral compression test was done using a universal testing machine. A statistically significant difference was found between the wrapped and unwrapped groups. Therefore, the use of a plastic-wrapped LCU influences the diametral tensile strength of composite resin. 1. Introduction Infection control during patient therapy is important in dentistry. Dentists use a light curing unit (LCU) during tooth filling to cure composite resins made of light-activated materials. However, there is a risk of cross-infection using this device. Many kinds of LCU exist with various light sources, with the most common having a light-emitting diode (LED) [1,2]. Various methods exist to prevent cross-infection through the LCU, such as use of disinfectants and autoclaves. However, the negative effects of these methods decrease the quality of the LCU [3]. One method that is not only effective and efficient, but also cost-effective and does not cause any negative effects is the use of cling wrap to cover the tip of the LCU [4 6]. Composite resin is a filling material that is activated by light. It has the same color as tooth enamel, and has good esthetic, physical, and mechanical properties [7]. Therefore, composite resin is used for anterior or posterior tooth filling [8]. Maan Ibrahim previously analyzed the effect of covering the tip of the LCU on the quality of composite resin and showed no difference in resin strength when activated by an uncovered or covered LCU [8]. However, that study also demonstrated a difference in light intensity between the uncovered and covered LCU. When using an LCU for posterior tooth filling, problems occurred when the tip of the LCU could not reach an ideal position because the posterior tooth was hard to reach and the tooth cusp increased the distance between the LCU and the surface of the filling material. This distance caused a decrease in light intensity, which can negatively affect some mechanical properties of the filling material [10]. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

Coutinho et al. showed that covering the tip of the LCU with cling wrap decreased and increasing distance affected the conversion degree of composite resin [11]. One mechanical property of composite resin is tensile strength, which allows the filling material to accept or resist maximal pressure before it cracks [12]. A diametral compression test will demonstrate the diametral tensile strength of composite resin [13]. This study analyzed the effect of using cling wrap to cover the tip of the LCU and of varying the distance of the LCU tip from the filling material surface on the diametral tensile strength of lightactivated composite resin. 2. Methods This experimental study was performed at the Dental Material Laboratory of the Faculty of Dentistry Universitas Indonesia, from October to December 2013. This study involved 60 specimens (30 lit by a cling-wrapped and 30 by an uncovered LCU unit) divided into six groups of five specimens each with curing distances of 0.5, 1, 2, 3, 4, and 5 mm from the surface of the material. The filling material used was GC SOLARE X shade A3 micro-fine hybrid composite resin. This universal filling material can be used for posterior or anterior tooth filling. Specimens were formed into a disk ±3.0 mm thick and ±6.0 mm in diameter based on American Dental Association (ADA) No. 27 specifications. The plastic cling wrap used in this study was made of polyvinyl chloride (PVC) 12.5 µm thick. The mold was filled in 2 mm increments based on the manufacturer s directions. After the second filling, the surface material was covered by a Mylar matrix and compressed by a glass slab. When finished, the matrix was removed. Curing in this study was performed using a LEDMax 450 Hilux LED curing unit after achieving a flat and dense surface material. All specimens were cured for the same time based on the manufacturer s instructions (20 seconds). For the covered LCU group, curing was performed after the tip of the LCU was covered by cling wrap, and the surface of the material was ensured to be flat with no bubbles or overlapping. The variation in distance curing was altered using the help of microscope slide glass. The specimens were immersed in a plastic pot containing Aquadest and incubated at 37 C for 24 hours. All specimens were tested with the Shimadzu AG-5000E Universal Testing Machine, with a maximum load of 250 kgf and crosshead speed of 0.5 mm/min. Specimens were positioned in the center of the testing machine. Pressure was applied until the material cracked and the diametral tensile strength was measured. Data were analyzed statistically by two-way analysis of variance (ANOVA) to determine the effects of a cling-wrapped LCU tip and curing distance on composite resin tensile strength. The Tukey test was performed to determine the difference in curing distance in specimen groups cured by a cling-wrapped LCU. 3. Results The diametral pressure test was performed in 60 specimens and the diametral tensile strength was measured. Table 1 shows the decreasing mean tensile strength of specimens cured by a cling-wrapped LED curing unit. The decrease occurred at all curing distances and was compared to that of all specimens cured by an uncovered LED curing unit. Table 1. Mean Composite Diametral Tensile Strength Curing Distance Mean Diametral Tensile Strength (MPa) No Wrap Wrap 0.5 mm 36.17 ± 3.61 31.67 ± 3.49 1 mm 34.35 ± 5.28 31.42 ± 2.95 2 mm 31.88 ± 3.45 30.23 ± 5.91 2

Table 1. Continue 3 mm 31.43 ± 4.84 29.96 ± 3.30 4 mm 31.40 ± 4.53 29.99 ± 2.79 5 mm 30.52 ± 2.58 28.12 ± 2.85 Total 32.63 ± 4.28 30.23 ± 3.57 There was a decrease in mean diametral tensile strength in both groups as the curing distance increased. All specimens showed a decrease in mean diametral tensile strength at the 1, 2, and 3 mm curing distances. For the uncovered LCU groups, the decrease continued in specimens at the 4 and 5 mm curing distances. However, in specimens cured by a cling-wrapped LCU, the tensile strength was enhanced when curing distance increased from 3 mm to 4 mm. Two-way ANOVA results showed a significance effect of cling-wrapped LED curing units on the diametral tensile strength of composite resin (P = 0.005). However, there was no difference between diametral tensile strength and curing distance (P = 0.05). Because our results demonstrated no differences in diametral tensile strength of specimens cured by the cling-wrapped LED curing unit, the Tukey test was performed to determine the effect of curing distance. The results showed no difference between curing distance and diametral tensile strength of the composite resin cured by the cling-wrapped LED curing unit (P > 0.05). 4. Discussion The results showed a difference between diametral tensile strengths of GC Solare X composite resin cured by a cling-wrapped and an uncovered LED curing unit. The difference was assumed to be due to the difference in light intensity between the covered and uncovered LED curing units. The light intensity from the cling-wrapped unit was assumed to have been decreased by the plastic film covering the tip. This was supported by the data of Maan Ibrahim [8], who showed that a plastic cover on the tip of an LCU led to decreased light intensity. Diametral tensile strength is a mechanical property of composite resin that depends on several factors, one of which is conversion degree. Conversion degree is the percentage of a total monomer molecule that is converted to polymer during a polymerization reaction [14]. In the polymerization process, the converted monomer would form a polymer chain through a molecule condensing process, resulting in contraction of the material [15]. If the intensity of energy were greater, the degree of conversion also would be greater. This is caused by the photoinitiator molecule, which was activated by the high light intensity. In the end, if many monomers were converted, the mechanical properties, including diametral tensile strength, of the composite resin also would be greater [14]. The decreased diametral tensile strength was assumed to be due to the use of cling wrap, which also is supported by the results reported by Coutinho et al. [11], who showed that cling wrap used to cover an LCU changed the light intensity and decreased the conversion degree of composite resin. The cling wrap that covered the LCU tip reduced the light intensity of the LCU due to the light dispersion phenomenon [11]. Also in our study, the Tukey test results demonstrated that variation in curing distance did not show any significant effect on diametral tensile strength of the composite resin. However, a decrease in composite resin diametral tensile strength due to the decreased light intensity on the composite resin occurred at any curing distance from 1 to 5 mm. The diametral tensile strength for composite resin in our study group ranged from 30 to 55 MPa [15]. However, at 3, 4, and 5 mm curing distances with the cling-wrapped LED curing unit, the value obtained was in the normal range despite the inadequate light intensity on the composite resin in those groups. As explained previously, the inadequate light intensity led to decreased conversion degree indicated by the low diametral tensile strength [14]. Though our results demonstrated that using cling wrap on the tip of the LED curing unit to prevent cross-infection has an effect on composite resin diametral tensile strength, treatment of patients must be based on ADA and Centers for Disease Control and Prevention (CDC) guidelines [16]. 3

Furthermore, other studies also must be done to demonstrate that the use of cling wrap will not have any detrimental effects on the composite resin, such as studies with a prolonged duration of curing and decreased incremental thickness so that better polymerization could be gained. 5. Conclusion It is concluded that the use of cling wrap on the tip of the LED curing unit has an effect on composite resin diametral tensile strength. However, the variation in curing distance (0.5, 1, 2, 3, 4, and 5 mm) from the surface of the material did not show any significance difference in composite resin strength when cured by a cling-wrapped LED curing unit. References [1] Antonson S A, Antonson D E and Hardigan P C 2008 Should my new curing light be an LED? Oper. Dent. 33 400. [2] Ariani D, Herda E and Eriwati Y K 2017 Effects of light intensity and curing time of the newest LED Curing units on the diametral tensile strength of microhybrid composite resins J. Phys.: Conf. Ser. 884 012106 [3] AlShaafi M M 2013 Effects of different infection control methods on the intensity output of LED Light-Curing Units. King Saud University J. Dent. Sci. 4 27. [4] Hodson N A, Dunne S M and Pankhurst C L 2005 The effect of infection control barriers on the light intensity of light-cure units and depth of cure of composite. Prim. Dent. Care 12 61. [5] McAndrew R, Lynch C D, Pavli M, Bannon A and Milward P 2011 The effect of disposable infection control barriers and physical damage on the power output of light curing units and light curing tips. Br. Dent. J. 210 E12. [6] Scott B A, Felix C A and Price R B 2004 Effect of disposable infection control barriers on light output from dental curing lights. J. Can. Dent. Assoc. 70 105. [7] Ronald L S and John M P 2012 Craig s restorative dental materials 13th ed (Philadelphia: Mosby) p 161. [8] Cobb D S, MacGregor K M, VARGAS M A and Denehy G E 2002 The physical properties of packable and conventional posterior resin-based composites: a comparison. J. Am. Dent. Assoc. 131 1610. [9] Al-Marzok M I 2012 The effect of wrapping of light-cure tips on the cure of composite resin. European J. Gen. Dent. 1 183. [10] Sobrinho L C, Lima A, Consani S, Sinhoreti M A C and Knowles J C 2000 Influence of curing tip distance on composite knoop hardness values. Braz. Dent. J. 11 11. [11] Coutinho M, Trevizam N C, Takayassu R N, Leme A A and Soares G P 2013 Distance and protective barrier effects on the composite resin degree of conversion. Contemp. Clin. Dent. 4 152. [12] Anusavice K J 2007 Philips science of dental materials 11th ed (St. Louis: Elsevier). [13] Brien W J O 2002 Dental materials and their selection 3rd ed (Illinois: Quintessence Publishing Co, Inc). [14] Lohbauer U, Rahitos C and Petschelt A 2005 The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite. Dent. Mater. 21 608. [15] Casselli D S M, Worschech C C and Paulillo L A M S 2006 Diametral tensile strength of composite resins submitted to different activation techniques. Braz. Oral. Res. 20 2013. [16] Control C D C 2003 Guidelines for Infection Control in Dental Health-Care Settings: MWWR. 4