Enhanced Cellular Automation Model For Detecting Heart Fibrillation

Similar documents
PART I. Disorders of the Heart Rhythm: Basic Principles

Full file at

CASE 10. What would the ST segment of this ECG look like? On which leads would you see this ST segment change? What does the T wave represent?

Shock-induced termination of cardiac arrhythmias

The Electrocardiogram

Systems Biology Across Scales: A Personal View XXVII. Waves in Biology: Cardiac Arrhythmia. Sitabhra Sinha IMSc Chennai

Automated Heart Analysis.

Shock-induced termination of cardiac arrhythmias

ECG. Prepared by: Dr.Fatima Daoud Reference: Guyton and Hall Textbook of Medical Physiology,12 th edition Chapters: 11,12,13

This presentation will deal with the basics of ECG description as well as the physiological basics of

A Dynamic model of Pulmonary Vein Electrophysiology. Harry Green 2 nd year Ph.D. student University of Exeter

Cardiac physiology. b. myocardium -- cardiac muscle and fibrous skeleton of heart

Introduction. Circulation

Chapter 12: Cardiovascular Physiology System Overview

CARDIOVASCULAR SYSTEM

A Cellular Automata Model For Dynamics and Control of Cardiac Arrhythmias DANNY GALLENBERGER (CARROLL UNIVERSITY) XIAOPENG ZHAO (UTK) KWAI WONG (UTK)

Simple finite-element model accounts for wide range

Electrocardiogram and Heart Sounds

Interpreting Electrocardiograms (ECG) Physiology Name: Per:

Chapter 16: Arrhythmias and Conduction Disturbances

Lab Activity 24 EKG. Portland Community College BI 232

Where are the normal pacemaker and the backup pacemakers of the heart located?

Lect.6 Electrical axis and cardiac vector Cardiac vector: net result Vector that occurs during depolarization of the ventricles Figure:

Human Anatomy and Physiology II Laboratory Cardiovascular Physiology

UNDERSTANDING YOUR ECG: A REVIEW

CRC 431 ECG Basics. Bill Pruitt, MBA, RRT, CPFT, AE-C

Lab 2. The Intrinsic Cardiac Conduction System. 1/23/2016 MDufilho 1

Developing Electrocardiogram Mathematical Model for Cardiovascular Pathological Conditions and Cardiac Arrhythmia

Cardiac Cycle. Each heartbeat is called a cardiac cycle. First the two atria contract at the same time.

THE CARDIOVASCULAR SYSTEM. Heart 2

ECG interpretation basics

Cardiac Telemetry Self Study: Part One Cardiovascular Review 2017 THINGS TO REMEMBER

EKG Abnormalities. Adapted from:

: Biomedical Signal Processing

ELECTROCARDIOGRAPHY (ECG)

Emergency Medical Training Services Emergency Medical Technician Paramedic Program Outlines Outline Topic: WPW Revised: 11/2013

Birmingham Regional Emergency Medical Services System

Decoding complex cardiac arrhythmia using mathematical optimization

Modeling Chaos in the Heart

ECG Interpretation Cat Williams, DVM DACVIM (Cardiology)

Chapter 13 The Cardiovascular System: Cardiac Function

WHAT S THAT RHYTHM I AM HEARING? GUIDE TO AUSCULTATION OF ARRHYTHMIAS IN HORSES

Collin County Community College

Electrical Conduction

ECG CONVENTIONS AND INTERVALS

Family Medicine for English language students of Medical University of Lodz ECG. Jakub Dorożyński

ECG Beat Recognition using Principal Components Analysis and Artificial Neural Network

Electrocardiography Biomedical Engineering Kaj-Åge Henneberg

SSRG International Journal of Medical Science ( SSRG IJMS ) Volume 4 Issue 1 January 2017

Neurons. Pyramidal neurons in mouse cerebral cortex expressing green fluorescent protein. The red staining indicates GABAergic interneurons.

Comparison of Different ECG Signals on MATLAB

HST-582J/6.555J/16.456J-Biomedical Signal and Image Processing-Spring Laboratory Project 1 The Electrocardiogram

Introduction to ECG Gary Martin, M.D.

Paramedic Rounds. Tachyarrhythmia's. Sean Sutton Dallas Wood

Electrocardiography for Healthcare Professionals

Mathematical modeling of ischemia and infarction

Medical Cyber-Physical Systems

Chapter 20 (2) The Heart

NONLINEAR DYNAMICS OF HEART RHYTHMS

Sheet 5 physiology Electrocardiography-

Modeling of Electrical Conduction in Cardiac Tissue III

ECG Interpretation Made Easy

The Function of an ECG in Diagnosing Heart Conditions. A useful guide to the function of the heart s electrical system for patients receiving an ECG

QUIZ/TEST REVIEW NOTES SECTION 1 CARDIAC MYOCYTE PHYSIOLOGY [CARDIOLOGY]

11/18/13 ECG SIGNAL ACQUISITION HARDWARE DESIGN. Origin of Bioelectric Signals

Circulatory system ( 循环系统 )

Farah Khreisat. Raghad Abu Jebbeh. Faisal Mohammad. 1 P a g e

ELECTROCARDIOGRAPHY (III) THE ANALYSIS OF THE ELECTROCARDIOGRAM

V. TACHYCARDIAS Rapid rhythm abnormalities

Principles of Anatomy and Physiology

Ventricular Parasystole

BIO 360: Vertebrate Physiology Performing and analyzing an EKG Lab 11: Performing and analyzing an EKG Lab report due April 17 th

A Review on Arrhythmia Detection Using ECG Signal

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

Cardiovascular system

BASIC CONCEPT OF ECG

- why the T wave is deflected upwards although it's a repolarization wave?

Analyzing the Heart with EKG

Storage is accomplished through the following mechanisms:

The cardiovascular system is composed of the heart and blood vessels that carry blood to and from the body s organs. There are 2 major circuits:

current, and acting like

Signal Processing of Stress Test ECG Using MATLAB

The Visible Man Dataset in Medical Education: Electrophysiology of the Human Heart

Lab #3: Electrocardiogram (ECG / EKG)

DR QAZI IMTIAZ RASOOL OBJECTIVES

Rate: The atrial and ventricular rates are equal; heart rate is greater than 100 bpm (usually between bpm).

Blocks classification by their constancy or steadiness

Electrocardiogram ECG. Hilal Al Saffar FRCP FACC College of medicine,baghdad University

Characteristics of the atrial repolarization phase of the ECG in paroxysmal atrial fibrillation patients and controls

physiology 6 Mohammed Jaafer Turquoise team

CRITICAL THINKING QUESTIONS AND ANSWERS AND CYCLE 2 LAB EXAM TEMPLATE. There are two main mechanisms that work in conjunction to return the blood

Figure 1 muscle tissue to its resting state. By looking at several beats you can also calculate the rate for each component.

4. The two inferior chambers of the heart are known as the atria. the superior and inferior vena cava, which empty into the left atrium.

Chapter 26. Media Directory. Dysrhythmias. Diagnosis/Treatment of Dysrhythmias. Frequency in Population Difficult to Predict

CORONARY ARTERIES. LAD Anterior wall of the left vent Lateral wall of left vent Anterior 2/3 of interventricluar septum R & L bundle branches

Simulation of T-Wave Alternans and its Relation to the Duration of Ventricular Action Potentials Disturbance

Pacemaker Concepts and Terminology*

3/26/15 HTEC 91. EKG Sign-in Book. The Cardiac Cycle. Parts of the ECG. Waves. Waves. Review of protocol Review of placement of chest leads (V1, V2)

How do arrhythmias occur?

Lab 7. Physiology of Electrocardiography

Transcription:

Enhanced Cellular Automation Model For Detecting Heart Fibrillation R. Touqan, A. Nasser & N. Hamdy Arab Academy for Science and Technology (AAST), email< rtouqan@hotmail.com Abstract: A new technique for human heart diseases diagnosis is presented. The technique is based upon the cellular automation and cellular membrane models. The coupling between the two models represents a key step in determining the action potential distribution, and hence a better view of the diagnosis. Beside ventricular arrhythmia other heart instabilities and ultimately chaotic behaviors can be detected. 1-Introduction : Heart disorders are due to conditions of abnormal impulse generation or abnormal impulse conduction in the myocardium. Abnormal impulse is manifested in either an enhanced automacity or a triggered activity due to some nonlinearities [1]. Abnormal impulse conduction is caused by circus movements of the depolarization wave in the form of a re-entrant wave form of excitation[2]. The spread of the depolarization from the Sinuatrial node (SAnode), to the atrioventricular node (AV-node) via the bundle of His, to the right bundle branch (L.B.B) and finally the perkenji fibers is an ordered process following a time schedule. The heart function integrity requires the above events to occur sequentially with correct timing. Many of the above events are subject to non-linear behavior, so the heart is susceptible to electrical instabilities leading to chaotic behavior [3]. Many researchers have investigated this behavior through the qualitative study of the cellular membrane models [4], that describe the cell behavior as microscopic events. The cellular automation model describes the propagation of this local microscopic event throughout the heart conduction network. We claim in this paper that the coupling between the two methods gives a better insight about the heart disorders and the early detection of the heart diseases. 2-Membrane Models of Cell activity The electrical activity of the myocardial cell is controlled by some gating variables, these variables control the inflow and outflow of the important ions, namely; (Na), (k), (CL), the following models are generic systems that show excitability, oscillatory activity and membrane action potential. 2-1- Hill Model: V = -1/k (V-V0)+I(t) U = -1/l (U-U0)+1/B (V-V.) 2-2-Fitz Hugh-Nagomo Model: V = V-V³/3-U+I(t) U = φ(v-bu+a) 2-3-Hind marsh & Rose Model: V = -av³+bv²+y-z+i Y = c-dv²-y Z = r[s(v-v1)-z] Where: V: Membrane potential, Y: Recovery variable I: Total synaptic current & a, b, c, d, are constants U: Time-varying threshould. 3-Cellular Automation and Recursive Growth 3-1- Finite State Automata (FSAs) (FSAs) Are a family of mathematical constructs that are defined by a finite set of states, output alphabets and rules that take the automation from its current states to the next state. One of the states is designated the initial state from which the execution of the (FSA) begins. A Cellular Automation (CA) is a spatially explicit form of a (FSAs). A set of cells are defined in a space, each cell is a (FSA) whose transition function depends on the cells own state and those of neighboring cells. Typically the symbolic output of (CAs) is the state of each cell.

The cellular automata employs a symbolic output to describe the growth of biological structures, it s a spatially explicit form of a (FSA). When the machine changes state it produces a symbol, the dynamics of the machine are reflected in the sequence that it produces. The set of sequences of symbols can be considered to be the language that the (FSA) produces and the state transition rules constitute the grammar that underlies the language. 3-2- Cellular Automata Model of Ventricular Excitation The cellular automata model developed by Mitchel et.al in (1992) in which each grid cell of the automation represents a homogeneous group of excitable units. Each grid cell is one of four possible states that define the cardiac action potential: (Quiescent, Excited, Absolute Refractory{can not respond to any excitation}, Relative Refractory). The relation of the four states to the ventricular action potential is shown in Figure.1 a representation of ventricular action potential; (b) Piecewise exponential stimulation threshold of relative refractory state. 4- The Proposed Model 4-1- Physiological Basis of the Model To investigate the nature of impulse propagation and the mechanisms of electrical instability, which precipitates arrhythmias, a model has been devised which simulates heart conduction processes. This modeling process has proven to be valuable in revealing the mechanisms of abnormal modes of impulse conduction. There are generally two main methods of modeling complex cardiac tissue. One uses 'phenomenological' models based on an inductive approach where the system is considered as a black box. The other is based on the deductive approach where the tissues behaviour is described by general biophysical laws. The deductive model for excitable media tends to be much more complex and relies on membrane theory according to which the action potential generation is described by the charging of the cell membrane capacitance by ionic currents. Because of the complexity of the deductive approach, which limits simulations to small areas of cardiac muscle, an inductive approach to modeling has been chosen which allows the development of a basic conduction model. The properties of the proposed conduction model are fundamentally determined by both the properties of the individual elements and the nature of the propagation between them. The concept of a formalized excitable medium is used to define the behaviour of individual elements and there interaction. The excitable medium comprises an array of discrete elements, with the physiological behaviour of each element defined in terms of a number of discrete states. At any time an element may be in one of four possible states. These are: Quiescent (at rest) Excited (depolarized) Absolute refractory (depolarized and in excitable) Relative refractory (recovering excitability) b Figure.1 Discrete simulation of electrophysiological properties of ventricular element. (a) Four-state The relative refractory phase is characterized by a gradual recovery of excitability, the simulation threshold falls from infinity (absolute refractoriness)

to a steady value corresponding to the quiescent level. This is simulated in the model by defining an exponentially falling relationship for the number of excited neighboring elements required to depolarize a relative refractory element with increasing refractory duration. The transition of an element between the states is related to the cardiac action potential. An element will remain in the quiescent state until it receives excitation from a neighboring element. Once a stimulus is conducted to the element, it depolarizes and passes into the excited state. In the excited state it has the ability to excite any of the eight neighbors, which becomes quiescent. In this state it can also contribute to the depolarization of a relative refractory element Figure.1-b. After a while, the element enters the absolute refractory state, during which it neither excites quiescent neighbors nor be excited itself. It then goes through the relative refractory state and eventually becomes quiescent again. It is assumed that all excited elements have action potentials of unit amplitude. This simple algorithm defines the basic neighborhood rule which controls the interaction of elements and the spread of conduction in the model. 4-2- Cylindrical Surface Model With Spatial Dispersion (Gaussian) of Refractoriness: To simulate the spatial dispersion of heart depolarization the refractory periods of the elements are defined in terms of a normal Gaussian distribution. The Gaussian probability function is selected because the variation in properties of many natural processes is known to follow this natural distribution. In this simulation the period values for each element are initially defined and remain fixed for the course of simulation. A procedure generates normally distributed random numbers for which a mean (M) and standard deviation (SD) have been defined to generate in dependent relative refractory period for each element. The structure of the excitable medium is represented initially as a two-dimensional network comprising an array of (50*50) square elements. The scale is chosen such that the properties of individual cardiac cells are not simulated; rather the model is macroscopic and hence represents the bulk properties of myocardial tissue. The two dimensional sheets are configured as cylindrical shell structure to simulate atrial and ventricle surface conduction. Simulation of the model is controlled by a pacemaker element situated at the upper edge of each cylinder as shown in Figure.2. Figure.2.(Two dimensional representation of the ventricle) 4-3- Model Electrocardiogram (ECG) The model simulates the electrical activity of the heart (ECG), which is derived from the vector summation of dipole sources between any adjacent quiescent and polarized element. By using the (ECG) data (durations, amplitudes) provided by the amplitude detector, the (ECG) can be constructed and simulated. 5-Results 5-1-Normal Heart Rhythm The simulated conditions of normal excitation and repolarization in the heart model are illustrated in Figure.3 The mean refractory period is taken as 250ms, with conduction velocity (CV) of 50cm/s, which are realistic values. The spatial dispersion of refractoriness is specified with a standard deviation

(SD) of 70ms. The excited state duration (EP) is 10ms, and the stimulation rate is set at 120beats/min (period SP of 500ms). The model activity is displayed as a profile map of element states with the cylindrical surface opened out as a two-dimensional sheet Figure.2. The discrete states are shown as different colors: Excited: Red, AR: Violet, RR: Brown, Quiescent: White. The model (ECG) is plotted underneath with markers on the time scale to indicate the time of state propagation. In the ventricular sheet the wave front propagates uniformly downwards and also radially to converge in the middle. The initial spread of depolarization through the ventricular surface produces a sharp positive deflection in the (ECG) followed by a corresponding downward deflection to the baseline as the wave front merges in the center, this well defined component of the (ECG) is the model equivalent of the (QRS) complex. The wave fronts continues to conduct downward and decays when reaching the lower edge Figure.3. Leaving in its wake a totally refracted region. After a time the refractory elements begin to repolarize. This repolarization progresses nonuniformly due to the spatially distributed refractoriness of the medium. Figure.3-b Figure.3-c Figure.3 Normal Ventricular Activity SP=500ms Ep=10ms Figure.3-a

5-2-Rhythm Disturbance & Electrical Alternans A variety of rhythm disturbances are observed in the simulations as the stimulation rate is raised. These are dependent on parameter conditions as illustrated in Figure.4-7. Figure.4-c Figure.4-a Figure.4 SP=200ms Ep=10ms Its seen that the normal rhythm of Figure.3 is transformed to a condition of electrical alternans followed by 2:1 conduction block as the driving interval is reduced from 500ms to 200ms,with a stimulation period of 200ms the depolarization wave fronts facing nearly most of the area in Absolute Refractory states which appear to stop its propagation, the diagnosis is (Ventricular Tachy Cardia). Figure.4-b

Figure.5-a Figure.5-c Figure.5 SP=500ms Ep=20ms Figure.5 illustrates a more severe alternans condition which exhibits gross rhythm disturbance, produced by increasing the excited state duration from 10ms to 20ms. The activity is instable and the diagnosis is (Premature Ventricular Contraction). Figure.5-b

Figure.6-a Figure.6-c Figure.6 SP=200ms Ep=20ms Figure.6 The effect of reducing the stimulation period to 200ms and the increasing the excited period to 20ms at the same time, the diagnosis is(ventricular TachyCardia, Premature Ventricular Contraction). Figure.6-b

Figure.7-a Figure.7-c Figure.7 SP=1600ms Ep=20ms Figure.7 The effect of increasing the stimulation period to 1600ms with EP=20ms can be seen and the diagnosis is (Idio Ventricular Rhythm). Figure.7-b

6-Conclusion A new technique for the human heart diagnosis is presented. The technique is based upon the cellular automation and the cellular membrane models. The coupling between the two models represents a key step in determining the action potential distribution. The model can be used to investigate the mechanisms involved in normal conduction as well as those which lead to electrical alternans and chaotic behaviors, a better view of the heart diagnosis can be obtained. 6- References [1] Sasyniuk B. I. " Concept of Re-entry Vrsus Automacity" Bretylium Tosylate Symposium,july, Am.J.Cardiology, s4, 1a - 6a, 1984. [2] Wit, A. L. & Cranefield, P. F. " Re-entrant Excitation As A Cause of Cardiac Arrhythmias " Am. J. physical, 35, H1 H17, 1978. Figure.8 SP=200ms SD=48ms Ep=36ms The simulation in Figure.8 shows that the normal rhythm has been interrupted by a stimulus delivered during the phase of maximum ventricular repolarization, the resulting wave front has spread out radially and become fractionated at many points around islands of refractory states. The activity begins to appear totally unsynchronized, and fibrillatory. [3] M. Sydqy "Control Of Heart Fibrilation Using Chaotic Synchronization" MSC Thesis, Arab Academy for Science & Technoloy, Alexandrea. Egypt.2002. [4] R. H.Mitchell, A. H. Bailie and J.McC Anderson " Cellular Automation Model of ventricular conduction" Medical & Biological Engineering and computing. September 1992 vol 30 p. 481 486. [5] P.Siregar, J.P.Ssintefe, M.Chahine & P.Lebeux "A Cellular Automata Model of The Heart and Its Coupling with a Qualitative Model" University of Rennes Cedex, France. [6] James W. Hafner "Modeling Biological Systems".Chapmen & Hall 1996 p. 378 39. [7] A. Van Oosterom "Genesis of the T wave as based on an Equivalent Surface Source Model" Department of Medical Physics, University of Nijmegen, The Netherlands. J. Electrocardiol. Vol 34S ; 2002; p. 217 227.