FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Similar documents
MARATHON Cross-Linked Polyethylene

Acetabular Cup System. Clinical Summary

PINNACLE Acetabular Cup System

Optimum implant geometry

SUMMIT and DURALOC. Clinical Summary

Understanding Hip Implant Options

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

The information contained in this document is intended for healthcare professionals only.

G7 ACETABULAR SYSTEM. beautifully. efficient.

Optimum implant geometry

Featuring. Technology. Product Rationale

D E S I G N R A T I O N A L E

Supplementary Appendix

Optimum implant geometry

Stability without compromise. Epsilon Durasul Constrained Insert

JOINT RECONSTRUCTION PORTFOLIO OVERVIEW

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education

Product Rationale. Where Strength and Modularity Connect

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

CORAIL Hip System. Clinical Summary

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Fixed and Variable Geometry Total Shoulder Arthroplasty

The information contained in this document is intended for healthcare professionals only.

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD

Active Articulation E1

This publication is not intended for distribution in the USA.

CERAMIC-ON-METAL. References: Cat No: version 2

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Bone Preservation Stem

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

PINNACLE REVISION CUP SYSTEM

Investigation performed at the Anderson Orthopaedic Research Institute, Alexandria, Virginia

Optimizing function Maximizing survivorship Accelerating recovery

Cementless Acetabular Fixation With and Without Screws

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

The Leader in Orthopaedic Innovation

Tri-Lock Bone Preservation Stem

CUTTING GUIDE SYSTEM PRODUCT RATIONALE. Custom-Made Patient Instruments for Total Knee Replacement

Move Ahead with Confidence. Hip Replacement Solutions from DePuy Orthopaedics

Rotating Platform System. Product Rationale

TriboFit Hip System. Issue 3 - August 2013 English

DEPUY SYNTHES SOLUTIONS

Zimmer Longevity Highly Cross-linked Polyethylene. Clinical Value Dossier - APAC

The proven, simple solution. CPT 12/14 Hip System

Sulzer Orthopedics Joint & Fracture Care

Zimmer TM. Continuum Acetabular System. Bringing together proven technologies.

TOTAL HIP REPLACEMENT:

Fixed Bearing Knees Function with Wear Resistance

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

The science of simplicity

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces

DURALOC. Acetabular Cup System. Surgical Technique

Trusted technology. Trusted performance. Supporting healthcare professionals

Furlong H-A.C. THR System

Don t let knee. arthritis pain wear you out

Arcos Modular Femoral Revision System

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

A Systematic Review on Performance of the Vanguard Complete Knee System

AML Hip System. Design Rationale/ Surgical Technique

simplicity THE SCIENCE OF DESIGN RATIONALE

INSTRUMENTS. Product Rationale

Cemented Cup. Surgical Technique

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

Bone Bangalore

RECLAIM REVISION HIP SYSTEM

INSTRUMENTS. Design Rationale

Poor mid-term results of total hip arthroplasty with use of a Hylamer liner

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

Rotating Platform. stabilityinmotion

CORAIL HIP SYSTEM DESIGN RATIONALE

HP KNEE EXTRACTION Instrumentation. Product Overview

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

Continuing the Tradition. VerSys Heritage Hip System

ReCap Product Rationale

PRODUCT RATIONALE & SURGICAL TECHNIQUE

Zimmer Segmental System

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

MicroSeal Total Hip Acetabular System. Like Nothing Else

Instrumentation Options

Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size

HIP CONTINUUM OF CARE. Trauma and Joint Reconstruction Hip Portfolio

The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties

*smith&nephew POLARCUP Dual Mobility System. Product Information

ACETABULAR CUP SURGICAL TECHNIQUE

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

CHARNLEY Wires. Surgical Techniques

ISO INTERNATIONAL STANDARD. Non-active surgical implants Joint replacement implants Particular requirements

111. ACETABULAR FIXATION

Pseudo tumor a cystic or solid mass (MRI or ultrasound) 1% of MOM pts develop pseudo tumors by 5 years 17 pts, all female, Pandit et al (JBJS, 2008)

Formosan Journal of Musculoskeletal Disorders

39 year old, 260 lb. park ranger. TKA in situ: 4 Years. First reported Metal-backed, non-modular PCA knee. 16% incidence. Modular metalbacked

Reaching new heights. Comprehensive. Efficient. Simple.

Transcription:

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Fixation First FIXATION FIRST 1958 Charnley Hip Over 1,000,000 implanted 1 96.2 percent survivorship at 32 years 2 Prodigy Hip 1977 Porocoat Porous Coating Over 1,000,000 prostheses with Porocoat Porous Coating implanted 1 1977 AML Hip Over 275,000 implanted 1 98.5 percent survivorship at 15 years 3 1981 Tri-Lock Hip Over 5,000 implanted 1 98 percent survivorship at 13.5 years 4 S-ROM Hip 1985 S-ROM Hip Over 75,000 implanted 1 98 percent survivorship at 5.3 years 5 Before discussing polyethylene performance, it is imperative to understand that proven fixation technology remains the single most important factor in ensuring successful clinical outcomes. 1 C.A. ENGH, MD C-Stem Hip 1986 Corail Hip Over 85,000 implanted 1 97.7 percent survivorship at 10 years 6 1986 HPS II Hip 1989 P.F.C. Hip 1990 Solution System Hip Over 35,000 implanted 1 Over 95 percent survivorship at 13.2 years 7 1991 Duraloc Cup Over 250,000 implanted 1 98 percent survivorship at 5 years 8 Solution System Hip Pinnacle Cup 1992 Prodigy Hip 1993 Endurance Hip Over 40,000 implanted 1 98.8 percent survivorship at 3-5 years 9 1994 C-Stem Hip Summit Hip 1997 Marathon Polyethylene 86 percent wear reduction in hip simulator studies 1999 Pinnacle Acetabular Cup System 2001 Summit Tapered Hip System AML Hip 2001 AML Hip System 2001 Summit Cemented Hip System

Wear Reduction WEAR REDUCTION Decreasing wear utilizing optimally cross-linked polyethylene will make a good hip even better. 1 T. SCHMALZRIED, MD 5 Mrad of cross-link inducing gammairradiation used in the Marathon process results in an 86 percent wear reduction in hip simulator studies.* 1 This minimal increase in gamma irradiation above historical levels of 2.5-4.0 Mrad dramatically reduces wear rates when compared to noncross-linked polyethylene. 1 1 Excessive wear and particulate generation can lead to osteolysis. The 25-year survivorship of arthroplasties with wear rates less than 15mm 3 /year exceeds 90 percent; in contrast, arthroplasty survivorship with wear greater than 56mm 3 /year is less than 30 percent at 20 years. 12 Doubling the cross-link inducing radiation dose to 10 Mrad decreases wear only an additional four percent but adversely impacts important material physical properties 10, 11 (Figures 1 and 4). Even when articulating against roughened femoral heads, Marathon Polyethylene continues to demonstrate significant reduction in wear rates in hip simulator studies.* 11 Marathon wear reduction benefits both primary and revision patients through the potential reduction of osteolysis. Marathon Polyethylene is the first FDA-cleared, third generation, cross-linked polyethylene. Marathon Polyethylene reduces wear by 86% in hip simulator studies, resists oxidation and exceeds minimum ASTM mechanical standards.* Marathon Polyethylene is an optimally cross-linked patented polyethylene. Patent #6,017,975

Oxidative Stability OXIDATIVE STABILITY Gamma In Air Oxidation FIGURE 2 Shelf-aged, gamma in air-sterilized polyethylene demonstrating significant oxidation. Eliminating oxidation while maintaining mechanical properties is imperative

Mechanical Integrity MECHANICAL INTEGRITY ASTM for clinical performance. 1 J. COLLIER, DE Physical and mechanical property measurements, such as elongation, predict material behavior. Maintaining these properties while reducing wear is critical to the successful clinical performance of cross-linked polyethylene. Wear rates are comparable among third generation highly cross-linked polyethylene components; however, independent artificial aging tests have identified surface layer oxidation that may result in increased wear for some competitive materials (Figures 2 and 3). 13 Marathon Polyethylene exceeds minimum ASTM standards for elongation and other important properties. As the radiation dose increases to 10 Mrad, elongation properties approach minimum ASTM standards. The results of mechanical property testing and wear simulations predict that Marathon Polyethylene will sustain the cyclic loads and motions required of a total hip arthroplasty.

Proven Technology PROVEN TECHNOLOGY Polyethylene that was cross-linked with gamma radiation has been the clinical gold standard for over 25 years. 1 H. MCKELLOP, PH D Cross-Link Inducing Gamma Radiation The clinical success of polyethylene cross-linked by gamma radiation is well documented and has been the orthopaedic gold standard 14-17 for more than 25 years. Gamma-irradiated polyethylene in the absence of oxidative degradation has been clinically successful. A process that combines the wear reduction benefits of gamma crosslinking and oxidative stability, such as the Marathon Polyethylene process, may benefit the patient. Gas Plasma Terminal Sterilization Marathon Polyethylene is terminally sterilized using gas plasma technology, which has been clinically proven through years of successful use with polyethylene. Gas plasma terminal sterilization introduces no radiation or free radicals into the polyethylene component, thus reducing oxidative potential. Alternative cross-link inducing radiation sources, such as electron beam, have no reported clinical documentation.

Proven Technology MARATHON PROCESS 1 2 1 Raw Material Quality controlled, calcium stearatefree polyethylene. 3, 4 2 Radiation Cross-Linking Consolidated polyethylene is treated with 5 Mrad of gamma radiation to induce cross-linking. The creation of free radicals during this process is a by-product of this step. 5 3 Thermal Treatment Irradiated polyethylene bars are thermally treated through a patented, proprietary process to force molecular recombination, extinguish free radicals, enhance material consolidation and reduce oxidative potential. 6 4 Quality Assurance After thermal treatment, each Marathon Polyethylene bar is thoroughly tested using Electron Spin Resonance (ESR). This test confirms the elimination of free radicals, assuring oxidative resistance. RESULTS The Marathon process provides 86 percent wear reduction in hip simulator studies, no free radicals and reduced oxidation. 1 Marathon Polyethylene is optimally cross-linked and processed for clinical success. 5 6 Manufacturing Cross-linked polyethylene bars are precision-manufactured into liners and packaged. Terminal Sterilization Packaged liners are gas plasma sterilized. This technique does not alter the polyethylene s molecular structure or introduce free radicals.

*In vitro wear results have not been correlated to clinical experience. References 1. Data on file at DePuy Orthopaedics, Inc. 2. Wroblewski, B.M. et al.: Lesson of Three Decades of Total Hip Arthroplasty. Contemporary Techniques and Issues in Orthopaedics: An Interactive Forum, Snowmass, Colorado, January 29-February 2, 2000. 3. Engh, C.A. et al.: Porous-Coated Total Hip Replacement, CORR, No. 298, pp. 89-96, 1994. 4. Pellegrini, V.D. et al.: The Tri-Lock Femoral System (Chapter 11). Total Hip Arthroplasty Outcomes, Churchill Livingston, New York, New York, 1998. 5. Christie, M.J. et al.: Primary Total Hip Arthroplasty with Use of the Modular S-ROM Prosthesis. JBJS, Vol. 81-A, No. 12, pp. 1707-1716, December 1999. 6. Vidalain, J.P.: Corail in Primary THR-Ten Year Experience. International Corail Conference, Malta, 1998. 7. Paprosky, W.G. et al.: Minimum 10-Year Results of Extensively Porous-Coated Stems in Revision Hip Arthroplasty. CORR, No. 369, pp. 230-242, 1999. 8. Fisher, D.A.: 5-Year Review of Second-Generation Acetabular Cup with Dome Screws. Journal of Arthroplasty, Vol. 14, No. 8, pp. 925-929, 1999. 9. Fisher, D.A.: Five to Eight Year Evaluation of a Cemented Stainless Steel Femoral Stem with a Grit Blasted Surface Finish. Advanced Techniques in Knee and Shoulder Reconstruction Meeting, September 30-October 3, 1999. 10. McKellop, H. et al.: Development of an Extremely Wear-Resistant Ultra High Molecular Weight Polyethylene for Total Hip Replacements. Journal of Orthopaedic Research, Vol. 17, No. 2, pp. 157-166, 1999. 11. McKellop, H. et al.: Wear of Gamma-Crosslinked Polyethylene Acetabular Cups Against Roughened Femoral Balls. CORR, No. 369, pp. 73-82, December 1999. 12. Sochart, D.H.: Relationship of Acetabular Wear to Osteolysis and Loosening in Total Hip Arthroplasty. CORR, No. 363, pp. 135-150, June 1999. 13. Muratoglu, O.K. et al.: The Comparison of the Wear Behavior of Four Different Types of Crosslinked Acetabular Components. 46th Annual Meeting, Orthopaedic Research Society, March 12-15, 2000. 14. Ranawat, C.S. et al.: Long-Term Results of the Total Condylar Knee Arthroplasty. CORR, No. 286, pp. 94-102, 1993. 15. Schulte, K.R. et al.: The Outcome of Charnley Total Hip Arthroplasty with Cement After a Minimum Twenty-Year Follow-up. JBJS, Vol. 75-A, No. 7, pp. 961-975, July 1993. 16. Neumann, L. et al.: Long-Term Results of Charnley Total Hip Replacement. JBJS, Vol. 76-B, No. 2, pp. 245-251, March 1994. 17. Kristensen, O. et al.: Long-Term Results of the Total Condylar Knee Arthroplasty in Rheumatoid Arthritis. JBJS, Vol. 74-B, No. 6, pp. 803-806, November 1992. Crossfire is a trademark of Stryker Howmedica Osteonics Corp., Longevity is a trademark of Zimmer, Inc. and Durasul is a trademark of Center Pulse. US Patents 6,316,158; 6,281,264; 6,242,507; 6,228,900; 6,017,975. For more information about DePuy products, visit our web site at www.jnjgateway.com/pinnacle. 1.5M0905 0601-76-050 (Rev. 3) DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46581-0988 USA Tel: +1 (800) 366 8143 Fax: +1 (574) 267 7196 DePuy International Ltd St Anthony's Road Leeds LS11 8DT England Tel: +44 (113) 387 7800 Fax: +44 (113) 387 7890 Printed in USA. 2000 DePuy Orthopaedics, Inc. All rights reserved.