Introducing F-MIRE Testing - Background and Concepts E-A-R 06-29/HP. E. H. Berger, M.S.

Similar documents
3M E-A-Rfit Validation System. FitTesting. for Hearing Protectors. Leading the Advancement of Hearing Conservation

Current Issues in Hearing Loss Prevention

Hearing Loss Prevention PM Session Ted Madison

Myths and Misconceptions about Hearing Protection E-A-R 11-13/HP. E. H. Berger, M.S.

Test Report on the. Authors: April 17, 2014

3M Center for Hearing Conservation

Hearing Protector Fit Testing: Practical Implications

UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017

Noise Attenuation of Earplugs as Measured by hreat and F-MIRE Methods in a Japanese Metal Manufacturing Plant

Hearing Conservation Program Regulations and Recommendations Summary

3M E-A-Rfit Validation System Frequently Asked Questions (FAQs) E-A-R 13-17/HP. Elliott H. Berger, M.S. Jim D. Brown, B.S., PMP Pegeen Smith, RN, MS

INTEGRAfit : Frequently Asked Questions

Hearing Conservation Program

Emerging Best Practices. Christine B. Petitti Directorate of Technical Support and Emergency Management OSHA

Environmental Health & Safety Policy Manual

Health, Safety, Security and Environment

UC Merced Hearing Conservation Program

Earplug Attenuation Validation As Part of a Hearing Conservation Program. David Friedman, CIH,MSPH, ARM Luminant

HEARING CONSERVATION PROGRAM

Field surveys of earplugs fit- testing in China

Field Attenuation Estimation Systems: THE POSSIBILITIES

Proceedings of Meetings on Acoustics

Effective Date: 27-February Table of Contents

HEARING CONSERVATION PROCEDURE

Model Safety Program

Establishing an Effective Hearing Conservation Program. Sarah E. Mouser, AuD, CCC-A Doctor of Audiology & Customer Relations Facilitator

User Efficacy in Fitting Hearing Protection. Theresa Y. Schulz, PhD. Lt. Col. USAF (ret.)

Vision Painting Inc. Safety Management System

Six Components of Hearing Conservation Program. Helene R. Freed, Ed.M Public Relations Specialist Industrial Hearing Testing

Workplace Noise Surveys: A Hands-On Measurement Workshop

Hearing Conservation Terminology Courtesy of Workplace Integra, Inc.

North Dakota State University Noise/Hearing Conservation


NC Employees Workplace Program Requirements for Safety and Health. Hearing Conservation

Craven Community College HEARING CONSERVATION PROGRAM

SOUTHERN UTAH UNIVERSITY S WRITTEN HEARING CONSERVATION PROGRAM December 2017

Santa Clarita Community College District HEARING CONSERVATION PROGRAM. Revised

HEARING CONSERVATION PROGRAM

HEARING CONSERVATION PURPOSE

Hearing Conservation Program April 27, 2018

Occupational Noise Exposure

The risk of noise-induced hearing loss (NIHL) depends

Villanova University Department of Environmental Health and Safety Policy and Procedure Manual

Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003

Environmental Health and Safety. Hearing Conservation Program

Hearing Conservation Program

Hearing Conservation Program. Southwestern Community College. Office of Human Resources

11. Hearing Conservation Program Chapter , WAC

Town of Brunswick. Hearing Conservation Plan

Health Standards to Protect Miners from Hearing Loss

Hearing Protection Systems

Hearing Conservation Program

THE CONTROL OF NOISE AT WORK REGULATIONS Guidance for Pub and Bar Operators

Hearing Conservation Program

Hearing Conservation Program

NOISE & HEARING CONSERVATION PROGRAM YALE UNIVERSITY

Excessive noise is a prevalent problem in the workplace

Workplace hearing loss is preventable.

SUNY Cortland Environmental Health and Safety Office Hearing Conservation Program

PREVENTING NOISE-INDUCED OCCUPATIONAL HEARING LOSS October 2003

AFRL-RH-WP-TR

Effect of hearing protection and hearing loss on warning sound design

Hearing Conservation

Prepared By: Blake Smith/James Stubbs

Delaware State University

Procedure. Procedure

Defining the minimum attenuations of a. personal hearing January protector. Gwenolé NEXER E-124.2

Life Can be Loud - Remember Your Hearing Protection E-A-R 03-02/HP. E. H. Berger, M.S.

TAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM

Hearing Conservation Program

BEAUFORT COUNTY COMMUNITY COLLEGE OCCUPATIONAL NOISE

Bringing Best Practices in Hearing Conservation to a Wider Audience

Rutgers Environmental Health and Safety (REHS)

Hearing Conservation Program Administration

This program is designed to prevent hearing loss for students, staff and employees while engaged in universitysponsored

UNCONTROLLED IF PRINTED Hearing Conservation

Gettysburg College. Hearing Conservation Program

Hearing Conservation Program

Your Company Hearing Conservation Program

Before taking field measurements, it is important to determine the type of information required. The person making the measurement must understand:

Contents. 1) Purpose ) Policy ) Definitions ) Procedure a) Requirements b) Noise standard... 4

noise induced Working Together to Prevent Hearing Loss

CCS Administrative Procedure H Hearing Conservation

East Carolina University

SNAP-ON INCORPORATED STANDARD ON HEARING CONSERVATION

Safety Services Guidance. Hearing protection

Six Components of Hearing Conservation Program. Helene R. Freed, Ed.M Public Relations Specialist Industrial Hearing Testing

Hearing Conservation Program. Santa Clara University 500 El Camino Real Santa Clara, CA 95053

HEARING CONSERVATION CHECKLIST

Hearing Conservation

Double hearing. protection. Gwenolé NEXER. Protection against noise E In what situation is the use of double hearing protection required?

HEARING CONSERVATION PROGRAM

Gettysburg College. Hearing Conservation Program

12th ICBEN Congress on Noise as a Public Health Problem

INDH 5131 Controls of Occupational Hazards. Noise & Hearing Conservation. Part II. V. Audiometric Testing

UC Santa Barbara Hearing Conservation Program Manual

HEARING CONSERVATION PROGRAM Texas Christian University

EFFECTIVENESS OF A HEARING CONSERVATION PROGRAM. Dr. Robert A. Bertrand, MD, FRCS(C)

Innovative Field Practices in Hearing Conservation Three Companies Share Strategies and Re-define Success

CITY OF FORT BRAGG HEARING CONSERVATION PROGRAM

Transcription:

Introducing F-MIRE Testing - Background and Concepts E-A-R 06-29/HP E. H. Berger, M.S. E A R / Aearo Technologies E A RCAL SM Laboratory 7911 Zionsville Road Indianapolis, IN 46268-1657 phone: 317-692-1111 fax: 317-692-3116 email: eberger@compuserve.com February 26, 2007 Version 1.4

ABSTRACT When a hearing conservationist wishes to select or assign a hearing protection device (HPD) for an employee, the data they have historically had available are based on optimized fitting scenarios in a controlled laboratory environment that bears little resemblance to the conditions under which workers wear HPDs on a daily basis. There are a number of problems with this approach, that are summarized in the following introductory paper along with a proposed solution namely field fit testing using a technology called field microphone-in-real-ear (F-MIRE). F-MIRE utilizes a miniature dual-element microphone to simultaneously measure the sound pressure levels in the earcanal under the hearing protector as well as those outside the HPD. These values, termed noise reduction (NR) can be used, with suitable correction factors, to estimate the hearing protector s attenuation for the particular individual and fitting that was tested. The applications of F-MIRE testing including training and motivation, training the trainer, assigning HPDs based on noise exposure, OSHA STS follow-up actions, assessment of compliance with OSHA requirements, program audits, and documentation for legal purposes, are discussed along brief descriptions of how the F-MIRE data can address these matters.

INTRODUCTION The question is how to select or assign a hearing protection device (HPD) to an individual user, taking into account his or her noise exposure, the amount of protection that is required, and potentially his or her hearing sensitivity as well. Today, hearing conservationists attempt to do this using labeled Noise Reduction Ratings (NRRs) that are provided by manufacturers in accordance with the Environmental Protection Agency s hearing protector labeling regulation. Though this might seem a reasonable approach it is fraught with error. The largest source of error is reliance on the EPA-required labeled values. These numbers are based upon an optimized fitting scenario in a controlled laboratory environment that bears little resemblance to the conditions under which workers wear HPDs on a daily basis, in what is often referred to as the real world (Berger, 1993). The other key problem with the laboratory measurements, as commonly utilized, is that averaged (mean) values for a group of 10 subjects are used to predict the performance for an individual wearer in an occupational setting. Even if the laboratory data were representative of the actual group using the device, the individual variability is large enough that attempts at predicting one person s performance from group data can easily err by up to 20 db (Gauger and Berger, 2004). The answer to both of these problems is individual fit testing. This technology has been available in the laboratory in many forms for nearly 30 years. In fact we at Aearo began publishing our research in this realm in 1984 (Berger, 1984; Berger, 1986; Berger 1988; Berger, 1989). Only recently has the hearing conservation community started to look more closely at this issue and in fact there are now a number of potential systems that provide solutions. Aearo, through its E A RCAL SM laboratory, was able to draw on its extensive experience to assess the various fit-testing methods and select the best. METHODS OF INDIVIDUAL FIT TESTING Historically the method of fit testing that has garnered the greatest attention is to replicate as closely as possible the laboratory test procedure. In the lab we ask listeners to track their hearing threshold levels (the quietest sounds they can hear) much like when they take a conventional audiogram to measure their hearing sensitivity. However, we present the sounds from loudspeakers in a test chamber and then repeat the procedure, both with and without HPDs. The difference in the two thresholds is the noise reduction of the device. This procedure is called real-ear attenuation at threshold (REAT) since the attenuation of the HPD is computed from differences in the threshold of hearing, with and without the hearing protector in place (Berger, 2000). To take REAT into the field, we replace the loudspeaker presentation with a headphone presentation, i.e. speakers in large circumaural cups, and in so doing limit ourselves to being only able to measure earplugs. However, earplugs are the type of HPD that is most variable in fit and therefore most in need of fit testing. A principal disadvantages of field REAT is its time-consuming nature since each frequency tested takes at least 30 seconds, a minimum of at least one minute to test the fit in each ear, much longer if multiple frequencies are to be tested. Furthermore there is an inherent variability since the data rely on the listener s ability to track his or her own threshold and that process itself has a substantial imprecision of approximately + 5 db for typical employees. And finally accurate REAT measurements require low background noise so that the open-ear thresholds are not masked and contaminated. Even though field REAT is conducted under large noise-excluding earmuff cups care must still be exercised to be sure that the environment in which the tests are conducted is adequately quiet.

T06-29/HP Introduction to F-MIRE Page - 2 An alternative approach is to make objective measurements with microphones, what is termed a microphone-in-real-ear (MIRE) technique (Berger, 1986). When applied in occupational settings this becomes a field-mire (F-MIRE) methodology (Voix, 2006). With F-MIRE we simultaneously record the sound pressure levels in the earcanal under the hearing protector as well as those outside the HPD. The difference is termed the noise reduction (NR). With suitable correction factors to account for known and measurable acoustic differences between the F-MIRE and REAT, the NR values can be used to estimate the hearing protector s attenuation. A test system is shown in Figure 1. Figure 1 - Illustration of key components of an F-MIRE system. The breakthrough embodied in Aearo s F-MIRE technology was the incorporation of a single small dual-element microphone and associated proprietary technology (Voix and Laville, 2002 and 2004;Voix, 2006). One section of the dual-element microphone couples through the earplug to sample the sound pressure levels in the earcanal, and the other section samples the external sound field. By developing special probed versions of Aearo earplugs we can now test in a matter of moments, the attenuation that is being obtained regardless of the fit of the HPD that is being evaluated. The actual measurement for any one fit in one ear takes about 10 seconds to obtain data at the standard 7 test frequencies from 125 Hz to 8 khz, as well as an overall noise reduction rating called the PAR (Personal Attenuation Rating). In addition to the brevity of the test it can be conducted in substantially higher noise levels than can a field REAT measurement. The PAR, though it appears to be an exact number, also contains its own variability, albeit much less than in the classical approach of using mean laboratory data for individual field predictions. The exact amount of variability in PAR is defined and explicitly provided with the measurement.

T06-29/HP Introduction to F-MIRE Page - 3 PURPOSE OF INDIVIDUAL FIT TESTING Individual fit testing serves many purposes in a hearing conservation program, but first and foremost it is a tool to train and motivate employees to wear their hearing protectors. A common shortcoming in hearing conservation programs (HCPs) is lack of training; even when training is attempted, lack of ability to demonstrate that the training has accomplished its goals presents a problem. With a quick and accurate fit-testing system like F-MIRE the hearing conservationist has a valuable tool to select the proper hearing protector in terms of fit, and then to work with the employee to make sure s/he has the knowledge and skill to repeatedly insert the product correctly. In turn this helps motivate the employee since they come to believe in the efficacy of their own behavior, i.e. it is worth the effort to do these things I can make a difference. Not only do the employees need training in the use of their HPDs, but so do the trainers themselves, need to learn how to train others. This train-the-trainer application is a key feature of the F-MIRE approach. Now trainers can learn what makes a difference and how to direct users to get the most from their hearing protection. Beyond correct fitting the hearing conservationist may wish to assign HPDs based on noise exposure levels and/or the need to communicate clearly. In fact European and Canadian standards (EN 458 and CSA Z94.2-02) specifically make such recommendations to match the HPD s attenuation to a 15-dB wide target protection window. Without individual fit test data like the F-MIRE can provide, this matching of HPD to noise exposure/communication scenario is a folly. With the reliable octave-band attenuation and PAR that the F-MIRE estimates, such HPD matching is now feasible and reasonable. When employees experience an OSHA-defined standard threshold shift (STS) one of the follow-up actions is to refit and retrain employees in the use of their HPDs and to provide more protective devices if needed. Now this can be done with a degree of reliability using F-MIRE to determine if in fact employees need this retraining, to assess the protection they can obtain, and whether more is needed. Companies are also often concerned if they are meeting OSHA requirements for adequate protection. The regulation directs them to use the labeled NRRs in spite of their unreliability. Alternatively when OSHA compares the relative efficacy of HPDs and hearing conservation, the employer is directed to derate by 50%. Neither approach is accurate. An F-MIRE alternative, though not yet approved by OSHA, is likely to become accepted because of its much greater face validity. This is an area in which Aearo will be arguing the case at the Federal level. Although F-MIRE is ideally intended for individual application there are times when a company may wish to audit a department or facility. F-MIRE could be applied on a large-scale basis by testing employees in a group and statistically summarizing and reviewing the results. Action could then be taken on an as-needed basis. A final application of F-MIRE is for documentation for legal purposes. Though not yet tested in court, the concept of documenting training and validating that an employee was able to demonstrate correct and adequate use of a hearing protector, would likely be valuable evidence in workers compensation proceedings.

T06-29/HP Introduction to F-MIRE Page - 4 FINAL REMARKS For over a quarter century since the advent of modern hearing conservation regulations, we have been saddled with the knowledge that many hearing conservation programs are ineffective. Too often this is due to the simple fact that the key component of those programs, the object between the employee and a hazardous noise exposure, namely the hearing protector, is not doing its job. Worn correctly and consistently, HPDs can prevent noise-induced hearing loss in virtually all cases. A giant step in the resolution of this problem is individual fit testing and F-MIRE now makes that possible. F-MIRE represents the next step forward in hearing conservation. It is not a panacea, but applied judiciously and consistently in one s overall hearing conservation efforts, the utility of such a tool is undeniable. As its use becomes more widespread, it is quite possible that such testing may become the standard for judging effective hearing conservation programs. REFERENCES Berger, E. H. (1984). "Assessment of the Performance of Hearing Protectors for Hearing Conservation Purposes," Noise & Vib. Control Worldwide 15(3), 75-81. Berger, E. H. (1986). "Review and Tutorial - Methods of Measuring the Attenuation of Hearing Protection Devices," J. Acoust. Soc. Am. 79(6), 1655-1687. Berger, E. H. (1988). "Use of Circumaural and Supra-Aural Earphones to Measure the Real-Ear Attenuation of Earplugs," Am. Ind. Hyg. Conf., San Francisco, CA, paper 39. Berger, E. H. (1989). "Exploring Procedures for Field Testing the Fit of Earplugs," in Proceedings, 1989 Industrial Hearing Conservation Conference, Off. Eng. Serv., Univ. Kentucky, Lexington, KY, 7-10. Berger, E. H. (1993). "EARLog #20 - The Naked Truth About NRRs," E-A-R Hearing Protection Products, Indianapolis, IN. Berger, E. H. (2000). "Hearing Protection Devices," in The Noise Manual, 5th Edition, edited by E. H. Berger, L. H. Royster, J. D. Royster, D. P. Driscoll, and M. Layne, Am. Ind. Hyg. Assoc., Fairfax, VA, 379-454. BSI (1994). Hearing Protectors Recommendations for Selection, Use, Care and Maintenance Guidance Document, British Stds. Inst. EN 458:1994, London, UK. CSA (2002). Hearing Protection Devices Performance, Selection, Care, and Use, Canadian Stds. Assoc. Z94.2-02, Rexdale, Ontario. Gauger, D. and Berger, E. H. (2004). A New Hearing Protector Rating: The Noise Reduction Statistic for Use with A Weighting (NRS A ), a report prepared at the request of the U. S. Environmental Protection Agency, reviewed and approved by ANSI S12/WG11, E A R 04-01/HP, Indianapolis, IN. Voix, J., Hager, L. D., and Zeidan, J. (2006). Experimental Validation of the Objective Measurement of Individual Earplug Field Performance, presented at EuroNoise 2006, Tampere, Finland. Voix, J. and Laville, F. (2002). Expandable Earplug with Smart Custom Fitting Capabilities, InterNoise 2002, Dearborn, MI. Voix, J. and Laville, F. (2004). New Method and Device for Customizing in Situ a Hearing Protector, Canadian Acoustics 32(3), 86-87.