Characterization of Used Cooking Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Similar documents
Marc Plante, Bruce Bailey, and Ian N. Acworth Thermo Fisher Scientific, Chelmsford, MA, USA

Determination of Olive Oil Adulteration by Principal Component Analysis with HPLC Charged Aerosol Detector Data

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Determination of Polymerized Triglycerides by High Pressure Liquid Chromatography and Corona Veo Charged Aerosol Detector

Analysis of Emulsifiers in Foods by High Pressure Liquid Chromatography and Corona Charged Aerosol Detection

Analysis of Phospholipids in Natural Samples by Normal Phase HPLC and Corona Charged Aerosol Detection

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Mercury Speciation Determinations in Asian Dietary Supplements

Fast UHPLC Methods for Analysis of Amino Acids

A Rapid UHPLC Method for the Analysis of Biogenic Amines and Metabolites in Microdialysis Samples

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Direct Determination of Native N-linked Glycans by UHPLC with Charged Aerosol Detection

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

Direct Analysis of Multicomponent Adjuvants by HPLC with Charged Aerosol Detection

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Novel, Universal Approach for the Measurement of Natural Products in a Variety of Botanicals and Supplements, Part 2

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

Impurity Profiling of Carbamazepine by HPLC/UV

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

A Versatile Detector for the Sensitive and Selective Measurement of Numerous Fat-Soluble Vitamins and Antioxidants in Human Plasma and Plant Extracts

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA

Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water

Sialic Acid Determination in Glycoproteins: Comparison of Two Liquid Chromatography Methods. Experimental. Introduction. Method 1.

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

Solving One of Chromatography s Biggest Dilemmas Proper Sealing of Chromatography Autosampler Vials

Ensuring High Sensitivity and Consistent Response in UHPLC-MS Analyses

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with Boron-Doped Diamond Electrode

Separation of 2AA-Labeled N-Linked Glycans from Glycoproteins on a High Resolution Mixed-Mode Column

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow

Novel Glycan Column Technology for the LC-MS Analysis of Labeled and Native N-Glycans Released from Proteins and Antibodies

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs

LC-MS/MS Method for the Determination of Tenofovir from Plasma

DETERMINATION OF COMPOSITION OF TRIACYLGLYCEROLS AND COMPOSITION AND CONTENT OF DI-ACYLGLYCEROLS BY CAPILLARY GAS CHROMATOGRAPHY, IN VEGETABLE OILS

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley

IC-MS Environmental Applications - Water Testing. Application Notebook

Determination of Tigecycline in a Cell Lysate

Title Revision n date

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Enhancing Sequence Coverage in Proteomics Studies by Using a Combination of Proteolytic Enzymes

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Determination of Water- and Fat-Soluble Vitamins in Nutritional Supplements by HPLC with UV Detection

Chromatography Vacuum Ultraviolet Spectroscopy

Increasing Extraction Efficiency of Wet Samples Using a Novel New Polymer During Accelerated Solvent Extraction

Increased Identification Coverage and Throughput for Complex Lipidomes

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

Fatty Acid Methylation Kits

Column Selection for the Analysis of Fatty Acid Methyl Esters Application

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Phospholipid characterization by a TQ-MS data based identification scheme

Determination of Ethyl Sulfate Impurity in Indinavir Sulfate Drug Using Ion Chromatography

Comparison of a UPLC Method across Multiple UHPLC Systems

Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA200

DRAFT TANZANIA STANDARD

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

A New Era in SFC Column Technology

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Application Note Soy for Isoflavones by HPLC. Botanical Name: Glycine max L. Common Names: Parts of Plant Used: Beans.

PAPRIKA EXTRACT SYNONYMS DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Testing robustness: Immunosuppressant drugs in blood with a TSQ Quantis MS for clinical research

2D-LC as an Automated Desalting Tool for MSD Analysis

Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method

Fatty acid profile analysis: Grape Seed Oil Sample Set Two ( )

Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column

They are substances that are soluble in lipid or derived from the lipids by hydrolysis; for examples, cholesterol and fat soluble vitamins.

Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

GlycanPac AXR-1 Columns

Acclaim C30 Column. Standards in Isopropanol. Saponified Chicken Fat Minutes

LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Edgar Naegele. Abstract

Results of Using Re-washed Vials and Closures

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Transcription:

Characterization of Used Cooking Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection Marc Plante, Bruce Bailey, and Ian N. Acworth Thermo Fisher Scientific, Chelmsford, MA, USA

Overview Purpose: To develop analytical methods to characterize used cooking oils by HPLC. Methods: High-pressure liquid chromatography (HPLC) methods using the Thermo Scientific Dionex Corona ultra RS charged aerosol detector, ultraviolet photodiode array detector (DAD), fluorescence detector (FLD), and the Thermo Scientific MSQ Plus mass spectrometer (MS) were developed and are detailed. Results: A variety of cooking oils, five used oils ( gutter oils ) and two fresh oils were analyzed, and their results are presented. The universal lipids method provided the fastest and most differentiating results to distinguish different oil qualities, and the HPLC-FLD-MS method provided information on aldehyde content of the samples. Introduction Cooking oils come from a variety of sources, including olive, rapeseed, peanut, grapeseed, mustard, corn, and many others. Cooking oil must be monitored for quality and contamination. When cooking oil is heated, it can undergo many chemical changes including oxidation of unsaturated fatty acids, triglyceride decomposition, and the formation of potentially cytotoxic oxidation products such as 4-hydroxy-trans-2-nonenal (HNE) and other aldehydes that are purported to be associated with Parkinsonʼs, Alzheimerʼs, Huntingtonʼs, atherosclerosis, liver diseases, and stroke. Rancidity during long term storage can also occur and is associated with the content of polyunsaturated fatty acid content. Although these issues make used oil unfit for use in the kitchen, and unhealthy for human consumption, it can still act as a useful resource as a raw material for biofuels production. As there is a significant price difference between high quality cooking oils and lower quality biofuel raw materials, the possibility exists for unscrupulous people to filter and decolorize used cooking oils and sell them as high quality cooking oils. Such treated used oils are referred to as gutter oils (GO). To provide some means of distinguishing fresh oil from gutter oil, we developed four HPLC methods. Three of these methods used the Corona ultra RS charged aerosol detector to determine different lipid components and ratios that were present in the samples. A fourth method used sample derivatization, fluorescence and mass spectrometry to determine aldehyde content. One method, based on a universal lipids analytical method, separates the majority of analytes by reversed phase (RP-HPLC) with focus on triacylglycerides (TAG) and their composition, diacylglycerides, and minor components. A second RP-HPLC method quantifies the free fatty acids resulting from base hydrolysis of the samples, with detectable changes in fatty acid composition. A third method, using normal phase (NP-HPLC), separates the samples by lipid class, including TAGs, free fatty acids, and DAGs a faster and simpler result than the first method. The charged aerosol detector is ideal for these analyses based on its relatively uniform response factor for nonvolatile analytes, and its high sensitivity. The detector operates by nebulizing analytes after they elute from the column, and placing a charge on the resulting analyte particles. Peak area is proportional to the amount of analyte (mass) entering the detector. Typical limits of quantitation are in the single-digit nanograms on column, and replicate injection precision values are two percent relative standard deviation on peak area. A fourth method, for aldehyde determination using HPLC with fluorescence (FLD) and mass spectrometry of derivatized oil samples, is also described with associated results. Identifications of aldehyde degradant components were made by mass spectrometry. Methods. Liquid Chromatography System: Reversed Phase HPLC System: Thermo Scientific Dionex UltiMate 3000 DGP-3600RS pump, WPS-3000RS autosampler, and TCC-3000RS column oven Liquid Chromatography System: Normal Phase HPLC System: Thermo Scientific Dionex UltiMate 3000 LPG-3400SD pump, WPS-3000RS autosampler, and TCC-3000RS column oven 2 Characterization of Used Cooking Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

RP-HPLC-Corona ultra RS Universal Lipids Method Sample Preparation: 100 µl (or equivalent mass) of sample dissolved in 900 µl methanol /chloroform (1:1) HPLC Column: Thermo Scientific Accucore C8, 2.6 µm 4.6 150 mm HPLC Column Temp.: 40 C Mobile Phase A: Methanol/water/acetic acid (650:350:4) Mobile Phase B: Acetonitrile Mobile Phase C: Isopropyl alcohol Detector: Corona ultra RS Detector Filter: 3 Nebulizer Temperature: 20 C Sample Temperature: 20 C Flow Rates: Elution Pump: 0.8 ml/min, Inv. Grad. Pump: 1.2 ml/min Injection Volume: 5 µl Flow Gradients: Elution Inverse Time (min) %A %B %C Time (min) %A %B %C -5.0 100 0 0-5.0 0.0 66.7 33.3 0.0 100 0 0 0.0 0.0 66.7 33.3 1.0 100 0 0 1.7 0.0 66.7 33.3 2.0 50 50 0 2.7 33.3 33.3 33.3 15.0 45 55 0 15.7 40.0 26.7 33.3 23.0 0 100 0 23.7 66.7 0.0 33.3 30.0 0 100 0 30.7 66.7 0.0 33.3 60.0 0 35 65 60.7 66.7 33.3 0.0 RP HPLC-Corona ultra RS Method for Omega Lipids/Free Fatty Acids Sample Preparation: Oil samples (50 μl aliquot) were dissolved/dispersed in 5 ml isopropanol/water (3:2) and 1 ml of 5 M KOH. All samples were heated in an 80 C water bath for 1 h with occasional stirring. After samples were cooled, a 500 μl aliquot was removed and 25 μl of formic acid was added to neutralize the sample. HPLC Column: Thermo Scientific Acclaim C30, 3 µm, 3.0 250 mm at 30 C Mobile Phase A: Methanol/MP B/acetic acid (900:100:3.6) Mobile Phase B: Acetone/acetonitrile/tetrahydrofuran/acetic acid (675:225:100:4) Detector: Corona ultra RS Detector Filter: 3 Nebulizer Temperature: 10 C Flow Rate: Elution Pump: 1.0 ml/min, Inv. Grad. Pump: 1.0 ml/min Injection Volumes: 5 µl Flow Gradients: Elution Inverse Time (min) %A %B 0.0 100 0 1.0 40 60 13.0 30 70 22.0 5 95 24.0 5 95 29.0 100 0 Time (min) %A %B 0.0 5 95 1.0 5 95 2.0 65 35 14.0 75 25 23.0 100 0 25.0 100 0 25.0 5 95 29.0 5 95 NP-HPLC-Corona ultra RS Method for Acylglycerols and Free Fatty Acids Sample Preparation: ~40 µl/ml of oil was dissolved in iso-octane/isopropanol (95:5) HPLC Column: non-endcapped CN, 3 µm, 4.0 150 mm, at 40 C Mobile Phase A: Iso-octane Mobile Phase B: Methyl-t-butyl ether, 0.4% acetic acid Mobile Phase C: iso-octane/n-butyl acetate/methanol/acetic acid (500:167:333:4) Detector: Corona ultra RS PowerFunction: 2.0 Detector Filter: 5 Nebulizer Temp.: 15 C Sample Temperature: 15 C Flow Rate: 1.0 1.2 ml/min Injection Volumes: 1 5 µl Thermo Scientifi c Poster Note PN70536_E 03/13S 3

Flow Gradient: Time (min) Flow Rate %A %B %C (ml/min) 0.0 1.0 100 0 0 0.0 1.0 100 0 0 2.0 1.0 95 5 0 6.0 1.0 93 7 0 12.0 1.0 60 40 0 13.0 1.2 40 0 60 13.5 1.2 20 0 80 13.7 1.2 20 80 0 15.0 1.2 40 60 0 16.0 1.2 100 0 0 Aldehydes Analyzed by Reversed-Phase HPLC with FLD and MS Detection Sample preparation: A 500 µl aliquot of oil sample solution (10 mg/ml in tetrahydrofuran), was mixed with 1000 µl of Hantzsch reagent in a 1.5 ml centrifuge tube. The solution was heated at 75 C for 1 hour. Samples were centrifuged (10,000 g for 3 mins), and the supernatant was transferred to an HPLC vial. The Hantzsch reagent was prepared as follows: 15 ml of denatured alcohol and 1 ml of water was mixed prior to the addition of 2 g of ammonium fromate. Once dissolved, a 1 ml volume of formic acid and 50 mg of 1,3-cyclohexanedione was added. The solution was brought to a 20 ml volume through the addition of denatured alcohol. HPLC Column: Acclaim 120 C18, 3 µm, 3.0 150 mm at 50 C Mobile Phase A: Water Mobile Phase B: n-propanol Detector 1: Thermo Scientific Dionex UltiMate 3000 FLD-3400RS Fluorescence detector Wavelengths: Excitation: 388 nm Emission: 455 nm Sensitivity: 2, Data Collection: 5 Hz Detector 2: Thermo Scientific MSQ Plus mass spectrometer Probe Temperature: 400 C Ionization: +mode ESI, Cone potential: +75 V Dwell Times: 1.00 s for SIM, 4.00 s for FSM Flow Rate: 0.5 ml/min, flow split (1:1) between FLD and MS Injection Volumes: 1 µl Flow Gradient: Time (min) %A %B -5.0 98 2 0.0 98 2 2.0 98 2 45.0 65 35 52.0 5 95 62.0 5 95 65.0 98 2 Data Analysis All HPLC chromatograms were obtained and compiled using Thermo Scientific Dionex Chromeleon Chromatography Data System software, 7.1 SR 1. Results RP-HPLC-Corona ultra RS Universal Lipids Method Qualitative comparisons were made between gutter oil samples and fresh soybean oil, and the chromatogram overlays are shown in Figure 1. Relative to the fresh oil, a few differences between gutter oil and soybean oil were found: fatty acid (measured by oleic acid peak area), monoglyceride, and DAG amounts increased, while TAGs decreased; and there was a change in the triglyceride distribution to heavier triglycerides, as indicated by the relative amounts of equivalent carbon number triglycerides (ECN). ECN is calculated using C-2n, where C is the number of carbon atoms and n is the number of double bonds in the alkyl chains. Other unidentified analyte peaks were also noted in the used oils. Levels of analytes that showed significant differences between soy bean oils and GOs are highlighted in red in Table 1. For comparison purposes the values for the oleic acid, DAG, and TAG component areas are relative to total peak area in the chromatogram, and the ECN amounts are relative to the total TAG peak area. 4 Characterization of Used Cooking Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

From a qualitative observation, the gutter oils GO4 and GO5 were of the least quality, being a cloudy, rancid gel. This is reflected in the high free oleic acid content, low triglycerides, and highest ECN 52:ECN 40 ratios. FIGURE 1. HPLC-Corona detector chromatogram of unused soybean oil and five gutter oils, normalized to the ECN 46 peak TABLE 1. Relative peak area analysis of two unused soybean samples and five gutter oil samples. Oil Oleic Acid DAG TAG ECN 40 ECN 48 ECN 52 Soybean-1 0.02 3.37 96.12 9.23 14.29 2.06 Soybean-2 0.03 1.10 98.77 7.66 13.96 1.39 GO1 1.21 8.70 80.99 5.62 24.04 3.72 GO2 0.93 14.35 82.77 4.12 22.81 4.29 GO3 0.02 4.50 91.82 11.06 13.96 2.33 GO4 1.46 11.76 79.01 6.38 23.75 6.42 GO5 2.47 11.76 79.40 1.50 27.90 6.90 RP HPLC-Corona ultra RS method for Omega Lipids/Free Fatty Acids Samples were hydrolyzed and analyzed to investigate any differences in the free fatty acid profiles of the different oil samples. In Figure 2, HPLC-Corona detector chromatogram overlays of soybean oil (#1) and a gutter oil (GO #5), showing changes in the fatty acid profile of the two oils as indicated by the arrows. MS analysis (-ve, ESI, -55V) revealed saturated and unsaturated fatty acids found in soybean oils. Agreeing with the results found in the Universal method, there were decreases in linoleic and linolenic acids compared to oleic acid with gutter oil compared to the soybean oil. FIGURE 2. HPLC-Corona detector chromatogram of fatty acids in unused soybean oil (red) and a gutter oil (#5) (blue) Thermo Scientifi c Poster Note PN70536_E 03/13S 5

NP-HPLC-Corona ultra RS Method for Acylglycerols and Free Fatty Acids Oil samples were prepared and analyzed by normal phase chromatography, which separates by the polar/hydrophilic moieties on the analytes. The free fatty acids were separated from the triglycerides, and the gutter oils were found to contain more free fatty acids and less triglycerides than the fresh soybean oil. The results of two oils are summarized in Table 2. Like the universal lipids method, increases in fatty acid and diglyceride content relative to the triglycerides was evident in the gutter oil samples. TABLE 2. Relative peak area analysis for gutter oil #2 and soybean oil #2 by normal phase chromatography Oil Aldehydes Analyzed by Reversed-Phase HPLC and FLD-MS Aldehydes in the samples were derivatized to their fluorescent acridine forms by the Hantzsch synthesis. Aldehyde derivatives were measured using HPLC-FLD; MS was used to obtain a molecular weight and possible identity of each aldehyde derivative. A chromatogram of GO4, showing a number of aldehyde derivatives is presented in Figure 3. Molecular weights (m/z) of the acridine derivatives are also given. Aldehyde peaks were identified by fluorescence and presence of a sodium adduct. All of the peaks shown in this figure are significantly larger or altogether new, compared to those found in unused soybean oil, indicating that aldehydes are produced upon heating. No 4-HNE was found in the samples, possibly due to its reactivity and the age of the samples undergoing analysis. FIGURE 3. HPLC-FLD-MS analysis of acridine-derivatized aldehydes found in GO4 Conclusions Four separate HPLC methods were used to characterize gutter oil compared to unused soybean oil controls. Different qualities of gutter oil were also evident, with GO3 consistently closest to unused soybean oil and GO5 being the worst. The universal lipids method still provided some distinguishing characteristic of GO3, seen as an increased amount of DAG content. Of the four methods developed and investigated for this study, the universal lipids method provided the most consistent determination between used and fresh cooking oils. The second method of choice was the aldehyde method, using HPLC-FLD-MS of derivatized aldehydes. The normal phase method would best serve as a fast screening tool for detection of samples with DAG and free fatty acids present. References Free Fatty Acid DAG TAG Other Soybean-2 0.0 0.04 99.4 0.56 GO2 0.3 6.8 91.5 2.6 6,606,897 counts 380 nm /455 nm Peaks Possible Aldehyde (R-CHO) 6,000,000 1. m/z 264.23 Glycoaldehyde 5,500,000 2. m/z 276.05 5,000,000 3. m/z 281.13 6-hydroxy-2,4-dienal 4. m/z 322.02 4,500,000 5. m/z 274.11 6 4,000,000 6. m/z 288.15 1 7. m/z 267.10 3,500,000 8. m/z 336.93 3,000,000 9. N/A 2,500,000 2,000,000 1,500,000 5 1,000,000 3 4 2 500,000 7 8 9 min -200,000 10.0 11.3 12.5 13.8 15.0 16.3 17.5 18.8 20.0 21.3 22.5 23.8 25.0 26.3 27.5 28.8 30.0 31.3 32.5 33.8 35.0 36.3 37.5 38.8 40.0 42.0 1. Zarkovic, N. 4-Hydroxynonenal as a bioactive marker of pathophysiological processes, Molecular Aspects of Medicine, 2003, 24, 281 291. 6 Characterization of Used Cooking Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

www.thermofisher.com/dionex 2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Australia +61 3 9757 4486 Austria +43 1 333 50 34 0 Belgium +32 53 73 42 41 Brazil +55 11 3731 5140 China +852 2428 3282 Denmark +45 70 23 62 60 France +33 1 60 92 48 00 Germany +49 6126 991 0 India +91 22 2764 2735 Italy +39 02 51 62 1267 Japan +81 6 6885 1213 Korea +82 2 3420 8600 Netherlands +31 76 579 55 55 Singapore +65 6289 1190 Sweden +46 8 473 3380 Switzerland +41 62 205 9966 Taiwan +886 2 8751 6655 UK/Ireland +44 1442 233555 USA and Canada +847 295 7500 PN70536_E 09/16S