CLINICAL SCIENCES. Differences in Visual Function and Optic Nerve Structure Between Healthy Eyes of Blacks and Whites

Similar documents
Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

CLINICAL SCIENCES. Steven L. Mansberger, MD; Pamela A. Sample, PhD; Linda Zangwill, PhD; Robert N. Weinreb, MD

The Role of the RNFL in the Diagnosis of Glaucoma

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

CLINICAL SCIENCES. (FDP) was designed to emphasize the response characteristics of the parasol

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

In some patients with glaucoma, standard (achromatic) automated

CLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

Correlating Structure With Function in End-Stage Glaucoma

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

CLINICAL SCIENCES. Baseline Topographic Optic Disc Measurements Are Associated With the Development of Primary Open-Angle Glaucoma

Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation

Relationship Between Structure

Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma

Intro to Glaucoma/2006

STANDARD AUTOMATED PERIMETRY IS A GENERALLY

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

Scanning laser polarimetry (SLP) provides real-time, objective

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

Glaucoma: Diagnostic Modalities

Linking structure and function in glaucoma

THE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

Investigation of the relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertension

Access to the published version may require journal subscription. Published with permission from: Elsevier

Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS

Receiver operating characteristic (ROC) curves are a wellaccepted

NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS

Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7

Ability of Scanning Laser Polarimetry (GDx) to Discriminate among Early Glaucomatous, Ocular Hypertensive and Normal Eyes in the Korean Population

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

CLINICAL SCIENCES. Validation of a Predictive Model to Estimate the Risk of Conversion From Ocular Hypertension to Glaucoma

Early Detection Of Glaucoma Clinical Clues. Points To Live By. Glaucoma Risk Factors 10/3/2014

Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1

NIH Public Access Author Manuscript Arch Ophthalmol. Author manuscript; available in PMC 2013 October 01.

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Clinical decision making based on data from GDx: One year observations

Optic disc damage has been shown to precede visual field

Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

21st Century Visual Field Testing

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection

Imaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

CLINICAL SCIENCES. optic neuropathy characterized

A Review Of Risk Factors. Early Detection Of Glaucoma Clinical Clues. A risk factor analysis is critical. Points To Live By

Position of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC

EXPERIMENTAL AND THERAPEUTIC MEDICINE 6: , 2013

RETINAL NERVE FIBER LAYER

The Measure of Confidence

Relationship between GDx VCC and Stratus OCT in juvenile glaucoma

Structural examina.on: Imaging

NIH Public Access Author Manuscript Br J Ophthalmol. Author manuscript; available in PMC 2014 November 01.

G laucoma is a progressive optic neuropathy in which

MEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association

Scanning Laser Tomography to Evaluate Optic Discs of Normal Eyes

Diagnostic Accuracy of Scanning Laser Polarimetry with Enhanced versus Variable Corneal Compensation

Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC)

Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements

Incorporating Risk Factors to Improve the Assessment of Rates of Glaucomatous Progression

LARGE DISCS WITH LARGE CUPS A DIAGNOSTIC CHALLENGE IN AFRICAN PATIENTS. Darshana Soma

Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial

Peripapillary Retinal Thickness. Maps in the Evaluation of Glaucoma Patients: A Novel Concept.

Assessing the Relationship between Central Corneal Thickness and Retinal Nerve Fiber Layer Thickness in Healthy Subjects

Test-retest variability in visual field testing using frequency doubling technology

Optical coherence tomography (OCT) is a noninvasive,

CLINICAL SCIENCES. African Descent and Glaucoma Evaluation Study (ADAGES)

Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach

Diagnosing open-angle glaucoma may be particularly

Relationship between central corneal thickness and parameters of optic nerve head topography in healthy subjects

Ganglion cell complex scan in the early prediction of glaucoma

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

OtticaFisiopatologica

Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer

Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation

Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma

MEDICAL POLICY. Proprietary Information of YourCare Healthcare

Scanning laser polarimetry (SLP) incorporates a confocal

Role of central corneal thickness measurement in management of open angle glaucoma and glaucoma suspects in Calabar, Nigeria

Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India

The Relationship between Standard Automated Perimetry and GDx VCC Measurements METHODS

3/16/2018. Perimetry

International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN

Reliability analyses of the GDx nerve-fiber analyzer

Key words: Glaucoma, Imaging, Ophthalmoscopy, Optic neuropathy, Topography

Evaluating Optic Nerve Damage: Pearls and Pitfalls

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

Central corneal thickness among glaucoma patients attending Menelik II Hospital, Addis Ababa, Ethiopia

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure

Introduction. Hemma Resch, Gabor Deak, Ivania Pereira and Clemens Vass. e225. Acta Ophthalmologica 2012

Transcription:

CLINICAL SCIENCES Differences in Visual Function and Optic Nerve Structure Between Healthy Eyes of and Lyne Racette, PhD; Catherine Boden, PhD; Shannon L. Kleinhandler, BSc; Christopher A. Girkin, MD; Jeffrey M. Liebmann, MD; Linda M. Zangwill, PhD; Felipe A. Medeiros, MD; Christopher Bowd, PhD; Robert N. Weinreb, MD; M. Roy Wilson, MD; Pamela A. Sample, PhD Objective: To investigate differences in visual function, optic disc topography, and retinal nerve fiber layer (RNFL) thickness between healthy eyes of blacks and whites. Methods: Visual function was assessed in healthy eyes of 5 blacks and 5 whites using standard automated perimetry, short-wavelength automated perimetry, and frequency doubling technology perimetry. Optic disc topography and RNFL thickness were measured using the Heidelberg Retina Tomograph and the optical coherence tomograph. Results: Mean standard automated perimetry mean deviations were within the normal range for both groups. had worse mean deviation values than whites using frequency doubling technology perimetry (mean±sd, 1.8±3.2 db vs.1±2.4 db), blacks had larger optic disc areas than whites using the Heidelberg Retina Tomograph (mean±sd, 2.1±.4 mm 2 vs 1.7±.4 mm 2 ), the RNFL of blacks was thicker than that of whites by 16.91 µm superiorly and 1.1 µm inferiorly using optical coherence tomography, and blacks had slightly higher intraocular pressures than whites (mean±sd, 16.5±2.5 mm Hg vs 15.2±3.2 mm Hg) and thinner central corneas (mean±sd, 54.5±43.2 µm vs 56.9±35.5 µm). No racial differences were found in mean RNFL thickness, pattern standard deviation on all tests, or any of the shortwavelength automated perimetry variables. Conclusions: Minimal racial differences in visual function were found, but race significantly affected optic disc topography and superior and inferior RNFL thickness measurements in healthy eyes. The racial differences observed for intraocular pressure could theoretically increase after correcting for central corneal thickness. Prospective studies are needed to further investigate these findings. Arch Ophthalmol. 25;123:1547-1553 Author Affiliations: Hamilton Glaucoma Center and Visual Function Laboratory, Department of Ophthalmology, University of California at San Diego, La Jolla (Drs Racette, Boden, Zangwill, Medeiros, Bowd, Weinreb, and Sample and Ms Kleinhandler); and Departments of Ophthalmology, University of Alabama at Birmingham (Dr Girkin), New York Eye and Ear Infirmary, New York (Dr Liebmann), and Texas Tech University, Lubbock (Dr Wilson). GLAUCOMA IS ONE OF THE leading causes of blindness worldwide. 1 It is characterized by retinal ganglion cell death that results in optic nerve damage and visual field loss. Primary open-angle glaucoma (POAG) is the most prevalent form of glaucoma. Racial differences in the prevalence of POAG are well documented and show that blacks are at higher risk for POAG than whites. 2 The reported prevalence rates are as much as 6 times higher in blacks as in whites. 3-6 Primary open-angle glaucoma is the leading cause of irreversible blindness in blacks, 3,7 and blacks with POAG are more likely than whites to develop visual impairment 8 and blindness. 8-1 Furthermore, POAG progresses more rapidly 11 and appears approximately 1 years earlier in blacks than in whites. 3,5,11 Although blacks are disproportionately affected by POAG, the underlying causes of this heightened susceptibility are unknown. Differences in measures of structure or visual function between healthy eyes of blacks and whites may account, at least in part, for the increased prevalence of POAG observed in the black population. Likewise, racial differences in intraocular pressure (IOP) and central corneal thickness (CCT) may also be significant in understanding why blacks are more susceptible to POAG. Understanding any differences will further our knowledge of the disease, refine diagnostic decisions, and improve the management of POAG in black patients. Racial differences in structural measures have been reported in healthy, 12-15 ocular hypertensive, 16 and glaucomatous eyes. 17 Fewer studies have been published on racial differences in visual function. In the present study, we investigate differences in retinal structure and visual function between healthy eyes of blacks and whites. We expect to replicate the previously observed findings in structural differences between blacks and whites and to determine whether racial differences exist for any of the visual function test results. 1547

To our knowledge, this is the first study to assess racial differences by using short-wavelength automated perimetry (SWAP) and frequency doubling technology (FDT) perimetry in healthy eyes. METHODS PARTICIPANTS We tested 1 healthy eyes from 1 participants (5 blacks and 5 whites). were recruited at the University of Alabama (n=21), the New York Eye and Ear Infirmary (n=11), and the University of California at San Diego Hamilton Glaucoma Center (n=18). Measures were implemented to ensure that testing procedures were comparable at all testing sites. Recruitment was solicited at work and school fairs, at local churches, and by word-of-mouth. We compared the results obtained in blacks with those in age-matched whites selected from the ongoing longitudinal Diagnostic Innovations in Glaucoma Study (DIGS) at the University of California at San Diego. The study followed the tenets of the Declaration of Helsinki and was approved by the institutional review boards at all 3 sites. All participants provided written informed consent and were minimally compensated for their participation. Inclusion Criteria Only individuals who identified their race as either black or white (by self-report) were included. Participant eligibility was based on findings from a complete clinical examination, which included a review of relevant medical history, best-corrected visual acuity, slitlamp biomicroscopy (including gonioscopy), Goldmann applanation tonometry, dilated funduscopy, stereoscopic ophthalmoscopy of the disc using a 78- diopter (D) lens, and simultaneous stereophotographs of the fundus. An ophthalmologic examination with normal findings, with no signs of ocular disease in both eyes, was necessary for inclusion as a healthy, nonglaucomatous participant. All participants had open angles, IOP of 22 mm Hg or less, no history of elevated IOP, best-corrected visual acuity of at least 2/4 in the studied eye, spherical refraction not greater than ±5. D, and cylinder correction not greater than ±3. D. All participants had simultaneous stereoscopic photographs of high enough quality to allow evaluation by trained graders. All participants had reliable visual field test results, defined as less than 33% of false-positive and false-negative errors, and less than 33% of fixation losses. Participants with diabetes mellitus or a family history of glaucoma were included in the study. Stereophotographs and structural and visual function tests were performed within a 6-month window, and all visual function tests were performed within a 3-month window. The order of testing was randomized across participants. Exclusion Criteria Participants were excluded from the study if they had a history of intraocular surgery, except for uncomplicated cataract surgery. The presence of congenital color vision problems, of any intraocular disease, or of disease affecting the visual field also resulted in exclusion. Participants with both photographbased optic disc defects and standard visual field defects (defined in the Standard Automated Perimetry subsection of the Visual Function Measures section) were excluded from the study. Some participants did not have all the test results available within the 6-month window. Thus, only a subgroup of participants was used for some analyses. STRUCTURAL MEASURES Simultaneous Stereophotographs Two experienced graders evaluated the stereophotographs. Each grader was certified after correctly grading standardized simultaneous stereophotographs. The graders were masked to the identity and ethnic background of the participants, to the results of the other grader, and to all other test results. When the 2 graders disagreed, a third grader evaluated the stereophotographs to determine the status of the optic disc. For this study, normal optic discs were defined as having no more than a.2 cup-disc ratio asymmetry between the 2 eyes and no evidence of excavation, neuroretinal rim thinning, notching or hemorrhages, or retinal nerve fiber layer (RNFL) defects. Confocal Scanning Laser Ophthalmoscope The confocal scanning laser ophthalmoscope (Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Dossenheim, Germany) uses confocal scanning laser technology to provide topographic measurements of the optic disc and the peripapillary retina. Detailed information concerning this instrument and a description of the variables have been provided elsewhere. 18,19 The following topographic variables were measured using the HRT software: disc area, rim area, cup shape, and mean RNFL thickness. Data from 25 blacks and 44 whites were available for this analysis. A mean topographic image was obtained from 3 scans (1 field of view) centered on the optic disc using HRT software version 2.1. Corneal curvature measurements were recorded using keratometry to correct for magnification. A trained technician, relying on simultaneous stereophotographs, outlined the optic disc margin on the mean topographic image. Optical Coherence Tomograph The optical coherence tomograph (OCT) (Carl Zeiss Meditec Inc, Dublin, Calif), software version A5X1, uses low-coherence inferometry to assess peripapillary RNFL thickness. The temporal delay in backscattered light between the RNFL and a reference mirror is used to estimate RNFL thickness. An edge-detection algorithm is used to differentiate the RNFL from other retinal layers. Details of this instrument have been described elsewhere. 2,21 In the present study, OCT was used to study mean RNFL thickness (36 measure) and temporal (316-45 measure), nasal (136-225 measure), superior (46-135 measure), and inferior (226-315 measure) quadrant thickness. Circular scans of 3.4-mm diameter centered on the optic disc were obtained for each participant. Image quality was assessed by an experienced grader masked to the identity and race of the participants and to the purpose of this study. Only images of good quality were included in the study. For most participants, the mean of 3 scans on each of the variables cited previously herein was used; however, when 3 good-quality scans were not available, the mean of 2 scans, or even a single scan, was used. Data from 42 blacks and 34 whites were available for this analysis. Pachymetry Measurements of CCT were obtained using an ultrasonic pachymeter (DGH-5 Pachette; DGH Technology Inc, Exton, Pa). Three measurements, in a 5-µm range, were averaged to obtain the CCT measurement. The CCT data were obtained from 38 blacks and 49 whites. 1548

VISUAL FUNCTION MEASURES We assessed participants using 3 different tests of visual function: standard automated perimetry (SAP), SWAP, and FDT perimetry. We evaluated mean deviation (MD) from agecorrected normal threshold values, pattern standard deviation, and the number of abnormal points (P.5) on the pattern deviation plot. Standard Automated Perimetry Automated perimetry in the central 24 of the visual field was conducted using the Humphrey Field Analyzer II (Carl Zeiss Meditec Inc). Visual fields were considered abnormal when the P.5 on the pattern standard deviation index or when findings from the Glaucoma Hemifield Test were outside normal limits. Although all participants were tested with SAP, some underwent testing using the full-threshold strategy and others using the Swedish Interactive Thresholding Algorithm (SITA). In both testing strategies, the targets consist of small (.47 ) white lights presented for 2 milliseconds on a dimly illuminated white background (1 candela [cd]/m 2 ). The detection of this target is nonspecific for a particular retinal ganglion cell subtype. In healthy individuals, SITA has been shown to yield approximately 2 more abnormal points on the pattern deviation plot than the full-threshold strategy. 22 Because we combined the results of the full-threshold and SITA testing strategies, and because the proportion of participants with full-threshold and SITA results was significantly different in our sample of blacks and whites ( 2 =14.9; P.1) (Table 1), we were concerned that the number of abnormal points might be biased in our groups owing to testing strategy. We therefore conducted a subanalysis in which only participants with SITA results were included. Sixty-nine healthy eyes of 69 participants (43 blacks and 26 whites) were included in this subanalysis. Short-Wavelength Automated Perimetry The Humphrey Field Analyzer II was used to perform SWAP on the central 24 of the visual field using the full-threshold strategy on 48 blacks and 5 whites. SWAP isolates a subpopulation of retinal ganglion cells by presenting a 1.8 blue target (44 nm) on a bright yellow background (1 cd/m 2 ) for 2 milliseconds. The small bistratified ganglion cells are best suited to detect this stimulus. They have large axons, process blueyellow color, and represent approximately 9% of the total retinal ganglion cell population. FDT Perimetry We also tested 43 blacks and 5 whites using FDT perimetry (Carl Zeiss Meditec Inc, and Welch Allyn, Skaneateles Falls, NY). The target is a.25 -cycle/degree sinusoidal grating presented in a 1 -diameter square window that undergoes 25-Hz counterphase flicker. The dependent measure is the contrast required to detect the target. We tested our participants using the N-3 program, in which targets are presented at 18 locations in the central 3 (2 temporally and 3 nasally). Frequency doubling technology perimetry is believed to target the magnocellular retinal ganglion cells, which have larger axons, process motion and fast flicker, and represent less than 1% of the total retinal ganglion cell population. STATISTICAL ANALYSIS Table 1. Distribution of 1 Healthy Eyes Tested Using the Full-Threshold and SITA Strategies on Standard Automated Perimetry in and The variables in this study were analyzed using 2 tests (for noncontinuous variables), Mann-Whitney rank sum tests (for continuous variables that were not normally distributed), and t tests (for continuous variables that were normally distributed) ( JMP software; SAS Institute Inc, Cary, NC). Statistical significance was set at P.5. Although many variables were included in this study, no adjustments for multiple comparisons were performed. 23,24 This is justified because these adjustments test the universal null hypothesis, that is, that all groups are similar on all variables. As is often the case, the universal null hypothesis is of no genuine interest in this study. Furthermore, adjustments for multiple comparisons imply that any given comparison is evaluated differently, depending on the number of tests performed. Guarding against spurious results with Bonferronilike adjustments may also prevent one from detecting real differences in the data. The sample size calculation was based on measures of visual function (MD on SAP) and structural measures (disc area on HRT) for which a variety of previous studies allow to approximate the standard deviations adequately. We assumed that a difference of.5 db on SAP MD between blacks and whites would be relevant in the context of this study. With =.5, 1 =.8, and an SD of 1.3, approximately 1 participants were needed. We assumed that a difference of.4 mm 2 in optic disc area between blacks and whites would be relevant. With =.5,1 =.8, and an SD of.4, approximately 32 participants were needed overall. RESULTS Eyes, No. (%) Full-Threshold SITA 7 (14) 43 (86) 24 (48) 26 (52) Abbreviation: SITA, Swedish Interactive Thresholding Algorithm. Only healthy eyes, based on findings from a complete ophthalmologic examination, were included in this study. However, it was expected that a proportion of these eyes would show abnormalities on either the stereophotographs or the visual field tests. We included participants with normal ophthalmologic examination findings and either photographic or standard visual field defects but not both. Thirty-one blacks (62%) and 37 whites (74%) had normal photographs and SAP field test results. Of the 5 blacks, 9 (18%) had photographic defects and 1 (2%) had field defects. Of the 5 whites, 7 (14%) had photographic defects and 6 (12%) had field defects. Differences between the 2 groups were not statistically significant. No racial differences were observed for age, spherical correction, or cylindrical correction (Table 2). A greater percentage of blacks reported a family history of glaucoma (31%) compared with whites (16%), although this was not significant ( 2 =3.2; P=.8). A significantly higher percentage of blacks also reported high blood pressure (P=.1) and diabetes mellitus (P=.4) (Table 2). also had significantly higher IOP (P=.3) and lower CCT (P=.2) measurements than whites. Figure 1 illustrates 1549

Table 2. Characteristics of the Study Population by Race No. Value No. Value Age, mean (SD), y 5 47.13 (8.11) 5 49.18 (9.23).13* Spherical correction, mean (SD), D 5.53 (1.72) 5 1.9 (1.89).6* Cylindrical correction, mean (SD), D 5.38 (.45) 5.39 (.55).64* Family history, % 48 31 49 16.8 Diabetes mellitus, % 48 6 5.4 High blood pressure, % 48 23 5 6.1 IOP, mean (SD), mm Hg 49 16.51 (2.53) 5 15.22 (3.15).3 CCT, mean (SD), µm 38 54.52 (43.22) 49 56.85 (35.46).2 Corneal curvature, mean (SD), D 49 7.8 (.25) 5 7.82 (.51).61* Abbreviations: CCT, central corneal thickness; D, diopters; IOP, intraocular pressure. *By Mann-Whitney test. By 2 test. Significant at P.5. By t test. Intraocular Pressure, mm Hg 25 2 15 1 5 45 5 55 6 65 7 Central Corneal Thickness, µm Figure 1. The relationship between intraocular pressure and central corneal thickness was not significant in whites (R 2 =.421) or blacks (R 2 =.2). The horizontal line is the regression line for both groups taken together. the lack of a significant relationship between IOP and CCT for both groups. No significant racial differences in corneal curvature were observed. Structural results are given in Table 3. had significantly larger optic disc areas than whites using the HRT. No racial differences were observed in rim area, cup shape, or mean RNFL thickness as assessed using the HRT. Using the OCT, no differences were observed in mean, nasal, and temporal RNFL thickness. However, blacks had a significantly thicker RNFL in the superior (P.1) and inferior (P=.2) quadrants than whites (149.8 and 141.7 mm vs 132.9 and 131.6 mm). The results of visual function testing are reported in Table 4. No significant differences were observed on any of the SAP variables (MD, pattern standard deviation, or number of abnormal points) when the fullthreshold and SITA testing strategies were combined. Similar results were observed when the analysis was repeated on the subgroup in which only the SITA strategy was used (Table 5). This subanalysis showed that blacks had a worse MD than whites ( 1.52 db vs.91 db), but the difference did not reach statistical significance. No significant differences were observed on any of the SWAP variables. The only significant racial difference in visual function was observed for the MD on FDT perimetry, for which blacks had more negative values than whites (P=.3). COMMENT The goal of this study was to determine whether differences in optic nerve structure and visual function exist between blacks and whites with healthy eyes. Such differences would have several implications. First, these differences should be taken into account when establishing a diagnosis of POAG and when deciding on the clinical management of the disease. Second, significant differences in visual function between blacks and whites with healthy eyes would result in the need to develop race-specific normative databases. The norms currently used in many of the studied devices were developed using predominantly white participants. Finally, prospective studies should be conducted to understand the reasons behind the increased prevalence of POAG in blacks. STRUCTURAL MEASURES There is evidence 12-15 that blacks with healthy eyes have larger optic discs than whites, and our results confirm these previous findings. Our results also support studies 12,14 that show no differences in mean neuroretinal rim area between blacks and whites. Other reported differences in optic nerve variables between healthy eyes of blacks and whites include larger cup-disc ratios 12,25,26 and cup volumes. 12 However, these differences must be interpreted with caution because the measurements of these optic nerve variables may depend on optic disc size. 16 The Confocal Scanning Laser Ophthalmoscopy Ancillary Study to the Ocular Hypertension Treatment Study, for example, found that blacks have significantly larger optic discs, optic cups, neuroretinal rims, and cup-disc ratios than other groups. 16 These differences in topographic op- 155

Table 3. Structural Differences Between Healthy Eyes of and No. Mean (SD) No. Mean (SD) HRT optic disc area, mm 2 25 2.5 (.4) 44 1.65 (.44).1* HRT rim area, mm 2 25 1.46 (.31) 44 1.35 (.33).17 HRT cup shape 25.22 (.8) 44.23 (.7).48 HRT mean RNFL thickness, µm 25 3. (7.) 44 27. (6.).9 OCT mean RNFL thickness, µm 42 114.86 (15.14) 34 18.5 (17.17).9 OCT temporal RNFL thickness, µm 42 84.55 (22.55) 34 81.97 (26.5).65 OCT nasal RNFL thickness, µm 42 82.86 (19.89) 34 88.24 (27.15).32 OCT superior RNFL thickness, µm 42 149.79 (21.45) 34 132.88 (19.57).1* OCT inferior RNFL thickness, µm 42 141.69 (2.23) 34 131.59 (15.2).2* Abbreviations: HRT, Heidelberg Retina Tomograph (Heidelberg Engineering, Dossenheim, Germany); OCT, optical coherence tomograph (Carl Zeiss Meditec Inc, Dublin, Calif ); RNFL, retinal nerve fiber layer. *Significant at P.5. By t test. By Mann-Whitney test. Table 4. Results of Visual Function Tests for the Healthy Eyes of and No. Mean (SD) No. Mean (SD) SAP MD, db 5 1.11 (1.45) 5.74 (1.24).18* SAP PSD, db 5 1.8 (.7) 5 1.78 (.54).66 SAP No. of locations 5% 5 4.82 (4.54) 5 3.96 (3.56).26 SWAP MD, db 48 4.11 (3.68) 5 2.73 (4.7).8* SWAP PSD, db 48 3.21 (.97) 5 3.21 (1.35).47 SWAP No. of locations 5% 48 4.15 (5.2) 5 4.3 (6.34).49 FDT MD, db 43 1.84 (3.19) 5.7 (2.42).3* FDT PSD, db 43 4.7 (2.82) 5 4. (1.35).35 FDT No. of locations 5% 43 3.5 (3.74) 5 2.38 (2.37).85 Abbreviations: FDT, frequency doubling technology; MD, mean deviation; PSD, pattern standard deviation; SAP, standard automated perimetry; SWAP, short-wavelength automated perimetry. *By t test. By Mann-Whitney test. Significant at P.5. Table 5. Results of Standard Automated Perimetry Using the SITA Strategy for the Healthy Eyes of and No. Mean (SD) No. Mean (SD) SAP-SITA MD, db 43 1.52 (1.51) 26.91 (1.37).1* SAP-SITA PSD, db 43 1.83 (.73) 26 1.8 (.68).95 SAP No. of locations 5% 43 5.37 (4.59) 26 5.46 (3.65).67 Abbreviations: MD, mean deviation; PSD, pattern standard deviation; SAP, standard automated perimetry; SITA, Swedish Interactive Thresholding Algorithm. *By t test. By Mann-Whitney test. tic disc variables were, however, explained by the larger optic disc area in blacks. Although it has been reported that blacks have a thinner mean RNFL than whites, 27,28 we found that the mean RNFL was generally thicker in blacks than in whites, although this difference did not reach statistical significance using either HRT or OCT. Testing a larger sample may lead to statistical significance, but the sample size used in this study provided enough power to detect small differences (approximately 8 µm) in mean RNFL thickness between blacks and whites using OCT. We report significantly thicker OCT measurements of RNFL in the superior and inferior quadrants in blacks than in whites. These differences in superior and inferior RNFL thickness may be partially due to differences in optic disc size between blacks and whites because a larger disc may contain more nerve fibers. More participants need to be tested to assess this theory with certainty. 1551

A B C Mean Deviation, db 1 1 Pattern Standard Deviation, db 2 1 No. of Abnormal Locations 4 3 2 1 Black White 2 FDT SAP SWAP 1 FDT SAP SWAP 1 FDT SAP SWAP Figure 2. Box plots for mean deviation (A), pattern standard deviation (B), and number of test locations less than 5% on the pattern deviation plot (C) are presented for frequency doubling technology (FDT) perimetry, standard automated perimetry (SAP), and short-wavelength automated perimetry (SWAP). The box represents the interquartile range, which contains 5% of all values. The horizontal line within the box indicates the median, and the whiskers extend from the box to the highest and lowest values, excluding the outliers (circles) and the extreme scores (asterisks). Outliers were defined as scores that were 1.5 to 3. box lengths from the upper or lower edge of the box, and extreme scores were defined as scores that were more than 3. box lengths from the upper or lower edge of the box. Although the mean values were within the normal range, more blacks than whites had values in the abnormal range. VISUAL FUNCTION Studies on racial differences in visual function in participants with healthy eyes are few. The Salisbury Eye Evaluation used the Humphrey Field Analyzer 81-point single-intensity screening strategy over a 6 field and reported a significantly higher number of missed points in blacks than in whites. 29 The Ocular Hypertension Treatment Study reported worse MD and pattern standard deviation values for blacks at baseline using SAP. 3 The Ocular Hypertension Treatment Study required normal SAP field test results and photographs at baseline, with all MD values within the normal range. Our results show no significant racial differences in any of the SAP variables. This result was confirmed in the subanalysis of participants tested using only the SITA strategy. Although this did not reach statistical significance, a trend was observed in which blacks had slightly worse MD values than whites on SAP in the main analysis and in the subanalysis. The number of abnormal points was higher using the SITA strategy in the subanalysis than when fullthreshold and SITA testing strategies were used. Although this difference did not reach statistical significance, it is in line with previous studies 22 suggesting that more abnormal points are present on SITA than on full-threshold testing. In this study, no racial differences were observed in any of the SWAP variables, although a trend was observed suggesting worse MD values for blacks than for whites. This finding may, however, be due to a lack of statistical power. Considering the sample size we used, a difference of 1.4 db on the MD could have been detected, assuming an SD of 3 db. The difference in MD that we observed was 1.38. Using FDT perimetry, blacks had significantly worse MD scores than whites, although most were within the normal range. To our knowledge, this is the first study to assess racial differences among the recently developed visual function specific tests. These tests include SWAP 31,32 and FDT perimetry, 33 which were shown to be more sensitive to early glaucomatous damage than the traditional achromatic SAP. 34 It is possible that the sensitivity of these tests allows them to capture small deficits in visual function in blacks who otherwise seem healthy, thus enhancing the potential usefulness of these tests. It is important to assess these differences because the normative databases against which the results of visual function tests are evaluated were developed using a predominantly white population. If healthy eyes of blacks and whites differ, the use of a predominantly white normative database may not be optimal for identifying values outside normal limits for other ethnicities. There may be a need to develop race-specific norms. Because only participants with healthy eyes were included in this study, we expected to obtain results within the normal range of values on each of the tests we performed. Mean results were well within the range of normality for all structural measures and tests of visual function in blacks and whites. However, participants with visual field defects were not excluded from the study. We therefore expected that some participants would be outside the normal range on measures of visual function. As shown in Figure 2, more blacks were outside the normal range. IOP AND CCT Although IOP is an important risk factor for POAG, the literature provides conflicting reports on race-specific differences in IOP. Some studies report elevated IOP in healthy blacks, 6,25,35-38 whereas studies from the population-based Baltimore Eye Survey showed no differences. 39 However, lower IOP levels were reported for untreated blacks at their initial examination for POAG compared with untreated whites. 39 Lower IOP, if present at glaucoma onset, may delay POAG detection and reduce the aggressiveness of treatment, possibly contributing to the faster progression of glaucoma in blacks. Differences in selection criteria and sources of patients make comparisons among studies difficult. The IOP levels reported for blacks may be artifactual and may depend on CCT. A positive correlation between IOP 1552

andccthasbeenestablishedforstandard 4,41 andportable 42 tonometers. There is mounting evidence suggesting that blacks have thinner corneas than whites. 42-44 Because IOP measurements of thin corneas tend to be artificially low, the true IOP of blacks may be underestimated. In this study, blacks had higher IOP levels and thinner central corneas than whites. It is therefore possible that the true IOP levels of the healthy blacks included in this study were underestimated because of their thinner corneas. Some blacks may have true IOP levels outside the normal range. It would be helpful to follow these participants to determine whether they are more likely to develop glaucoma. CONCLUSIONS The results of this study show that blacks with healthy eyes have larger optic discs, poorer MD values on FDT perimetry, higher IOP levels, and thinner corneas than whites. These differences are in line with previous studies of optic disc size, IOP, and CCT. Potential study limitations include the relatively small number of participants tested, particularly on some of the tests. As a result, statistical power was inconsistent across comparisons. This study is not a population-based survey, and caution should be used when generalizing the results. Prospective studies with more participants are needed to confirm our results and to determine whether racial differences in measures of visual function warrant the need to develop race-specific reference values. Submitted for Publication: April 15, 24; accepted February 9, 25. Correspondence: Pamela A. Sample, PhD, Department of Ophthalmology, University of California at San Diego, 95 Gilman Dr, La Jolla, CA 9293-946 (psample @glaucoma.ucsd.edu). Financial Disclosure: Drs Weinreb and Sample have received research support from Carl Zeiss Meditec Inc, Dublin, Calif. Funding/Support: This study was supported by R1 grants EY828 (Dr Sample) and EY118 (Dr Zangwill) from the National Eye Institute, National Institutes of Health, Bethesda, Md; the Glaucoma Research Foundation, San Francisco, Calif (Dr Sample); The EyeSight Foundation of Alabama, Birmingham (Dr Girkin); and K23 grant EY13959-1 from the National Eye Institute, National Institutes of Health (Dr Girkin). REFERENCES 1. Thylefors B, Negrel AD, Pararajasegaram R. Epidemiologic aspects of global blindness prevention. Curr Opin Ophthalmol. 1992;3:824-834. 2. Racette L, Wilson MR, Zangwill LM, Weinreb RN, Sample PA. Primary openangle glaucoma in blacks: a review. Surv Ophthalmol. 23;48:295-313. 3. Sommer A, Tielsch JM, Katz J, et al. Racial differences in the cause-specific prevalence of blindness in east Baltimore. N Engl J Med. 1991;325:1412-1417. 4. Tielsch JM, Sommer A, Katz J, Royall RM, Quigley HA, Javitt J. Racial variations in the prevalence of primary open-angle glaucoma: the Baltimore Eye Survey. JAMA. 1991;266:369-374. 5. Wilensky JT, Gandhi N, Pan T. Racial influences in open-angle glaucoma. Ann Ophthalmol. 1978;1:1398-142. 6. Martin MJ, Sommer A, Gold EB, Diamond AL. Race and primary open-angle glaucoma. Am J Ophthalmol. 1985;99:383-387. 7. Wallace J, Lovell HG. Glaucoma and intraocular pressure in Jamaica. Am J Ophthalmol. 1969;67:93-1. 8. Muñoz B, West SK, Rubin GS, et al. Causes of blindness and visual impairment in a population of older Americans: the Salisbury Eye Evaluation Study. Arch Ophthalmol. 2;118:819-825. 9. Grant WM, Burke JFJ. Why do some people go blind from glaucoma? Ophthalmology. 1982;89:991-998. 1. Hiller R, Kahn HA. Blindness from glaucoma. Am J Ophthalmol. 1975;8:62-69. 11. Wilson R, Richardson TM, Hertzmark E, Grant WM. Race as a risk factor for progressive glaucomatous damage. Ann Ophthalmol. 1985;17:653-659. 12. Chi T, Ritch R, Stickler D, Pitman B, Tsai C, Hsieh FY. Racial differences in optic nerve head parameters. Arch Ophthalmol. 1989;17:836-839. 13. Mansour AM. Racial variation of optic disc size. Ophthalmic Res. 1991;23:67-72. 14. Varma R, Tielsch JM, Quigley HA, et al. Race-, age-, gender-, and refractive error related differences in the normal optic disc. Arch Ophthalmol. 1994;112:168-176. 15. Tsai CS, Zangwill L, Gonzalez C, et al. Ethnic differences in optic nerve head topography. J Glaucoma. 1995;4:248-257. 16. Zangwill LM, Weinreb RN, Berry CC, et al. Racial differences in optic disc topography. Arch Ophthalmol. 24;122:22-28. 17. Girkin CA, McGwin G Jr, Long C, DeLeon-Ortega J, Graf CM, Everett AW. Subjective and objective optic nerve assessment in African Americans and whites. Invest Ophthalmol Vis Sci. 24;45:2272-2278. 18. Weinreb RN, Lusky M, Bartsch DU, Morsman D. Effect of repetitive imaging on topographic measurements of the optic nerve head. Arch Ophthalmol. 1993; 111:636-638. 19. Zangwill LM, Bowd C, Weinreb RN. Evaluating the optic disc and retinal nerve fiber layer in glaucoma II. Semin Ophthalmol. 2;15:26-22. 2. Bowd C, Weinreb RN, Williams JM, Zangwill LM. The retinal nerve fiber layer thickness in ocular hypertensive, normal, and glaucomatous eyes with optical coherence tomography. Arch Ophthalmol. 2;118:22-26. 21. Zangwill LM, Bowd C, Berry CC, et al. Discriminating between normal and glaucomatous eyes using Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph. Arch Ophthalmol. 21;119:985-993. 22. Bengtsson B, Heijl A. Comparing significance and magnitude of glaucomatous visual field defects using the SITA and Full Threshold strategies. Acta Ophthalmol Scand. 1999;77:143-146. 23. Perneger TV. What s wrong with Bonferroni adjustments. BMJ. 1998;316:1236-1238. 24. Savitz DA, Olshan AF. Multiple comparisons and related issues in the interpretation of epidemiologic data. Am J Epidemiol. 1995;142:94-98. 25. Beck RW, Messner DK, Musch DC, Martonyi CL, Lichter PR. Is there a racial difference in physiologic cup size? Ophthalmology. 1985;92:873-876. 26. Kroninger DL, Newcomb RD. Clinical investigation of the cup/disc ratio. JAm Optom Assoc. 1984;55:54-57. 27. Poinoosawmy D, Fontana L, Wu JX, Fitzke FW, Hitchings RA. Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry. Br J Ophthalmol. 1997;81:35-354. 28. Tjon-Fo-Sang MJ, Lemij HG. Retinal nerve fiber layer measurements in normal black subjects as determined with scanning laser polarimetry. Ophthalmology. 1998;15:78-81. 29. Rubin GS, West SK, Muñoz B, et al. A comprehensive assessment of visual impairment in a population of older Americans: the SEE Study. Invest Ophthalmol Vis Sci. 1997;38:557-568. 3. Gordon MO, Kass MA. The Ocular Hypertension Treatment Study: design and baseline description of the participants. Arch Ophthalmol. 1999;117:573-583. 31. Sample PA, Weinreb RN. Color perimetry for assessment of primary open-angle glaucoma. Invest Ophthalmol Vis Sci. 199;31:1869-1875. 32. Sample PA, Weinreb RN. Progressive color visual field loss in glaucoma. Invest Ophthalmol Vis Sci. 1992;33:268-271. 33. Johnson CA, Samuels SJ. Screening for glaucomatous visual field loss with frequency-doubling perimetry. Invest Ophthalmol Vis Sci. 1997;38:413-425. 34. Sample PA, Bosworth CF, Blumenthal EZ, Girkin C, Weinreb RN. Visual functionspecific perimetry for indirect comparison of different ganglion cell populations in glaucoma. Invest Ophthalmol Vis Sci. 2;41:1783-179. 35. David R, Livingston D, Luntz MH. Ocular hypertension: a comparative follow-up of black and white patients. Br J Ophthalmol. 1978;62:676-678. 36. Coulehan JL, Helzlsouer KJ, Rogers KD, Brown SI. Racial differences in intraocular tension and glaucoma surgery. Am J Epidemiol. 198;111:759-768. 37. Seddon JM, Schwartz B, Flowerdew G. Case-control study of ocular hypertension. Arch Ophthalmol. 1983;11:891-894. 38. Klein BE, Klein R. Intraocular pressure and cardiovascular risk variables. Arch Ophthalmol. 1981;99:837-839. 39. Sommer A, Tielsch JM, Katz J, et al. Relationship between intraocular pressure and primary open angle glaucoma among white and black Americans. Arch Ophthalmol. 1991;19:19-195. 4. Johnson M, Kass MA, Moses RA, Grodzki WJ. Increased corneal thickness simulating elevated intraocular pressure. Arch Ophthalmol. 1978;96:664-665. 41. Hansen FK. A clinical study of the normal human central corneal thickness. Acta Ophthalmol (Copenh). 1971;49:82-89. 42. Dohadwala AA, Munger R, Damji KF. Positive correlation between Tono-Pen intraocular pressure and central corneal thickness. Ophthalmology. 1998;15: 1849-1854. 43. Brandt JD, Beisere JA, Kass MA, Gordon MO. Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS). Ophthalmology. 21;18:1779-1788. 44. La Rosa FA, Gross RL, Orengo-Nania S. Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations. Arch Ophthalmol. 21;119:23-27. 1553