Design a system of measurement of heart rate, oxygen saturation in blood and body temperature with non-invasive method

Similar documents
Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices

Continuous Monitoring of Blood Pressure Based on Heart Pulse Analysis

Estimation of Haemoglobin Using Non-Invasive Technique

Optical Sensor System for Hemoglobin Measurement

Research Journal of Pharmaceutical, Biological and Chemical Sciences

Heart Rate Monitoring System Using Lab View

Journal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE

Permanent City Research Online URL:

Correlation of Ratio of Ratio of Near Infrared Vs Infrared Photoplethysmograph Spectroscopy for the Non-Invasive Measurement of Haemoglobin

Biomedical Instrumentation D. The Photoplethysmogram

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Blood Pressure Estimation Using Photoplethysmography (PPG)

Non-invasive Hemoglobin Measurement for Anemia Diagnosis

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

ECG Acquisition System and its Analysis using MATLAB

ISSN: [Cortes* et al., 7(3): March, 2018] Impact Factor: 5.164

Biomedical Instrumentation E. Blood Pressure

WIRELESS PATIENT HEALTH MONITORING SYSTEM

Monitoring of Blood Glucose Level

Smart Wearable Body Sensors for Glucose Monitoring

Heart Attack Detection and Heart Rate Monitoring Using IoT

and Technology I. INTRODUCTION METHOD & MATERIAL

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

BLOOD GLUCOSE LEVEL MONITORING BY NONINVASIVE METHOD USING NEAR INFRA RED SENSOR

Design and Development of Non-Invasive Kiosk for Self-Care Health Management

Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

Design of the HRV Analysis System Based on AD8232

Design and Development of Non-Invasive Prototype to Measure Pulse Rate, Blood Glucose and Oxygen Saturation Level in Arterial Blood

Experiment B-18 Heart Rate and Coughing

JAMES R. KNIGHT

Heart Abnormality Detection Technique using PPG Signal

Dye Sensitized Solar Cells (DSSC) Performance Reviewed from the Composition of Titanium Dioxide (TiO2)/Zinc Oxide (ZnO)

Design of Remote Monitoring System for the Detection of Vital Signs

Light is wearable Health Monitoring and Fitness Tracking Light is OSRAM

POWER EFFICIENT PROCESSOR FOR PREDICTING VENTRICULAR ARRHYTHMIA BASED ON ECG

How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve

Hybrid EEG-HEG based Neurofeedback Device

DESIGN OF AUTOMATIC INSULIN DOSAGE INDICATOR FOR DIABETIC PATIENTS USING BMI

Appendix D An unresponsive patient with shallow, gasping breaths at a rate of six per minute requires:

Appendix E Choose the sign or symptom that best indicates severe respiratory distress.

Optical sensor for Indian Siddha Diagnosis System

Classification of heart signal using wavelet haar and backpropagation neural network

ALCO Regulations. Protocol pg. 47

Non-Invasive Method of Blood Pressure Measurement Validated in a Mathematical Model

Development of an Optical Sensor Based System for Detection and Monitoring of Hemoglobin in Blood

Health Tech Symposium Fall, Dan Sommers P.E. EMT-P

IOT BASED NON-INVASIVE ACQUISITION OF HEALTH PARAMETERS

ANALYSIS OF PHOTOPLETHYSMOGRAPHIC SIGNALS OF CARDIOVASCULAR PATIENTS

Optical non-invasive methods for characterization of the human health status

Choosing Mindray SpO2

Photoplethysmographic measurements from central nervous system tissue

Solar Powered Non-Invasive Pulse Oximeter and Heart Rate Meter

II. PROCEDURE DESCRIPTION A. Normal Waveform from an Electrocardiogram Figure 1 shows two cycles of a normal ECG waveform.

Surgical Monitoring Mouse and Rat Made Easy

Dr. D.McG.Clarkson Determining the Accuracy of SpO2 Values

ANDROID APPLICATION BASED LIVE HEALTH CARE MONITORING SYSTEM

The Heart 1 of 34 Boardworks Ltd 2012

Development of esmoca RULA, Motion Capture Instrumentation for RULA Assessment

SUBJECT INFORMATION AND CONSENT FORM

Respiration and Heartbeat Signal Measurement with A Highly Sensitive PVDF Piezoelectric Film Sensor

A bioimpedance-based cardiovascular measurement system

Blood Pressure Determination Using Analysis of Biosignals

City, University of London Institutional Repository

Heart Rate Analysis for Human Factors: Development and Validation of an Open Source Toolkit for Noisy Naturalistic Heart Rate Data

Muscle OxyGen monitor. The Science Behind Moxy

Competitive Intelligence Report Technology & Patents

Western Hospital System. PSG in History. SENSORS in the field of SLEEP. PSG in History continued. Remember

Signal Quality Analysis in Pulse Oximetry: Modelling and Detection of Motion Artifact

Development of Bio-impedance Analyzer (BIA) for Body Fat Calculation

Design and Dynamic Modeling of Flexible Rehabilitation Mechanical Glove

A Simple Portable ECG Monitor with IOT

Lab #3: Electrocardiogram (ECG / EKG)

Research Article Advanced Pulse Oximetry System for Remote Monitoring and Management

Zacurate CMS 500DL. Finger Pulse Oximeter. User Manual

Finger Pulse Oximeter. User Manual. Einstein Associates LLC Stafford Centre Drive Suite B Stafford, TX

Fatigue Impact to Mechanical Movement of Maximal Instep Kicking in Soccer

Dual channel photoplethysmography studies of cardio-vascular response to the body position changes

April 18, Dear Mr. Lei Chen:

Outline. Electrical Activity of the Human Heart. What is the Heart? The Heart as a Pump. Anatomy of the Heart. The Hard Work

EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND PPG

Design and Implementation study of Remote Home Rehabilitation Training Operating System based on Internet

Pancreas: digestive enzymes Liver: bile-helps to digest fat, stored in gallblader; breaks down toxins, makes some parts of blood

Application of PPG Signal Processing to Patients undergoing Angioplasty Procedure

PHONOCARDIOGRAPHY (PCG)

Development of Rule-Based Recognition Systems for Continuous Monitorization of Pulse Oximetry

EMBEDDED PROJECTS-IEEE-NON IEEE DOMAINS

TEPZZ _ 849 A_T EP A1 (19) (11) EP A1. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.

Oxygen Level Measurement Techniques: Pulse Oximetry

Blood Pressure 1 of 22 Boardworks Ltd 2011

escco, estimated Continuous Cardiac Output device DESEBBE OLIVIER SAUVEGARDE CLINIC, LYON, FRANCE

Non-contact Screening System with Two Microwave Radars in the Diagnosis of Sleep Apnea-Hypopnea Syndrome

Testing Masimo rainbow Technology with vpad-a1 1. Background

RASPBERRY PI BASED ECG DATA ACQUISITION SYSTEM

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: 2-4 July, 2015

Keun-Ho Kim and Sang-Suk Lee* Department of Oriental Biomedical Engineering, Sangji University, Wonju , Korea

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial

Wrist Energy Fuzzy Assist Cancer Engine WE-FACE

Spectral and brain mapping analysis of EEG based on Pwelch in schizophrenic patients

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

Smart Dress(Shirt/Band) Hospital Application (Cardiac Disorder Detection Remotely)

Transcription:

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Design a system of measurement of heart rate, oxygen saturation in blood and body temperature with non-invasive method To cite this article: M T Tamam et al 2018 IOP Conf. Ser.: Mater. Sci. Eng. 403 012038 View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 22/12/2018 at 14:18

Design a system of measurement of heart rate, oxygen saturation in blood and body temperature with non-invasive method M T Tamam 1, A J Taufiq 1 and A Kusumawati 2 1 Electrical Engineering Department, 2 Medical Faculty Universitas Muhammadiyah Purwokerto Jl. Raya Dukuhwaluh Kembaran, Banyumas, Jawa Tengah, Indonesia 53182 tamam@ump.ac.id Abstract. Heart disease is the number one cause of death in the world. The heart functions to pump blood flowing through the veins or arteries to all parts of the body. In the blood contains many levels of molecules or constituents, such as oxygen in blood HbO 2 (oxyhemoglobin). This study aims to design a system used to measure changes in voltage fluctuations to the transducer (photoplethysmography), oxygen saturation and changes in body heat. From the test result got error value at measurement of SpO 2 equal to 0.89% and for measurement of BPM (heart rate) equal to 3.095%, difference or difference measurement of body temperature sensor got error value equal to 0.78%. 1. Introduction The human body consists of various vital organs that are interconnected and have a unique and complex function. The heart as a vital organ that serves to provide oxygen throughout the body and cleanse the body of the metabolism (carbon dioxide). Heart disease is the number one cause of death in the world, so the need for early detection of this disease. The pulse can be measured at any point on the body where the vibrations in the arteries are sent to the surface frequently when it is pressed against a structure that lies beneath such a bone [1]. Pulse oximetry is a non-invasive method for measuring the percentage rate of hemoglobin saturation. This method uses the different wavelengths of red light (660 nm) and infrared light (940 nm) captured by the detection sensors after passing through the veins and capillaries at the tip of the index finger [2]. Pulse oximetry serves to manage long-term patients with oxygen therapy and to identify patients with congenital heart disease. Pulse oximetry has a high accuracy for detecting congenital heart disease in newborns [3]. Photoplethysmography is an optical technique of detecting cardiovascular pulse waves (heart) from the fingertips. By exploiting optical sensor reflection then warming the area around the skin, this is evidenced by the increasing beats component of photoplethysmography [4]. The design of monitoring of integrated signal monitoring system on a platform of system on chip (SoC) and wireless technology in hospital with monitored parameter is ECG and body temperature then processed using microcontroller. Results from data processing are sent to the web server using wireless communications [5]. Detection of beat pressure (pulse) is an integration of most analytical techniques for arterial blood pressure (ABP), intracranial pressure (ICP) and pulse oximetry signals (SpO2). Pulse detection is used Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd 1

to estimate heart rate in ABP signals, to classify ICP morphology and to estimate blood pressure using pulse oximeter wave [6]. Therefore, medical record media of heartbeat, oxygen saturation in blood and body temperature are computationally computed and study of observation approach of health condition of body without any surgery or physical or non-invasive, and is expected to prevent human death due to abnormalities heart early because of the less than optimal medical record and responsive. 2. Materials and methods This section explains the materials and methods used in this research. 2.1 Materials Heart rate sensor and oxygen saturation in blood, body temperature sensor, Arduino Board Due, MULTISIM software, and BASCOM SIMULATOR software. 2.2 Method The selection of sensor types used for the measurement of heart rate parameters, oxygen saturation and body temperature with the measuring unit of each monitoring parameters placed on the fingers, then by analyzing the work characteristics and suitability of each component supporting the idea of design obtained the initial design is steady and optimal both in terms of mechanical, electronic and ergonomic. The block diagram of the proposed method is shown in figure 1 and the design of the pulse oximetry sensor is shown in figure 2. SPO 2 /HbO 2 Heart rate Body temperature Control unit & Data acquisition Display Figure 1. Block diagram of the proposed method. Figure 2. Design of pulse oximetry sensor. 2

3. Results and discussions The system is a form of heart rate detection application by sensing the change in blood volume in the finger arteries as the heart pumps blood. It consists of an infrared LED that transmits an IR signal through the subject's fingertip, from the part reflected by the blood cells. The reflected signal is detected by the photo diode sensor. The change in blood volume with the heart rate at the output of the photodiode is not too large to be detected directly by the microcontroller. Therefore, two stages of high gain and active low pass filter are required, the design uses two operational amplifiers (Op-Amp) to filter and amplify the signal at the appropriate voltage level so that the analog signal can perform computation by the microcontroller. Table 1 shows the results of SPO 2 testing of ten respondents with an average error of 0.89%. Table 2 shows the test results from BPM (heart rate) to ten respondents with an average error of 3.095%. Table 1. Results of SPO 2 testing. No Respondent R SPO 2 Led IR Difference % 1 Respondent 1 2.0 2.0 1.0 85.0 2 Respondent 2 1.0 2.0 0.5 97.5 3 Respondent 3 1.8 2.0 0.9 87.5 4 Respondent 4 1.8 1.8 1.0 85.0 5 Respondent 5 1.4 2.0 0.7 92.5 6 Respondent 6 1.0 1.0 1.0 85.0 7 Respondent 7 2.0 2.0 1.0 85.0 8 Respondent 8 1.4 1.4 1.0 85.0 9 Respondent 9 1.4 2.0 0.7 92.5 10 Respondent 10 1.0 2.0 0.5 97.5 Table 2. Heart rate test results. No. Heart Rate (bpm) ECG BIOPAC (bpm) Error (%) 1 74 73.35 0.886 2 68 67.80 0.295 3 78 75.00 4.000 4 82 77.00 6.494 5 70 72.90 3.978 6 64 69.40 7.781 7 86 83.00 3.614 8 80 81.00 1.235 9 78 77.00 1.299 10 74 75.00 1.333 Table 3 shows the value of human body temperature test results against ten respondents with an average error of 0.78% The results of the measurement of heart rate parameters, oxygen saturation in blood and body temperature are represented in units of measured values displayed on 16x2 LCD. The measurement value is fluctuating, because the measurement uses non-invasive method (without surgery). 3

No Table 3. Body temperature test results. Respondent Body Temperature (ºC) Digital Thermometer Measuring Instrument Error (%) 1 Respondent 1 37.0 37.12 0.32 2 Respondent 2 36.5 36.76 0.71 3 Respondent 3 36.6 36.71 0.30 4 Respondent 4 36.3 36.76 1.26 5 Respondent 5 35.6 36.14 1.51 6 Respondent 6 36.6 37.02 1.14 7 Respondent 7 36.7 36.92 0.59 8 Respondent 8 36.8 37.12 0.86 9 Respondent 9 36.9 36.98 0.22 10 Respondent 10 36.7 37.04 0.92 4. Summary The system created in this study has been able to work in accordance with the planning, which can measure heart rate, oxygen saturation in blood and body temperature. From the test results can be concluded that the difference or different pulse oximetry sensor measurement obtained error value on measurement of SPO 2 of 0.89% and for the measurement of BPM (heart rate) of 3.095%. Differences or differences in body temperature sensor measurement obtained error value of 0.78%. Difference or difference between measurable and measured measurements caused by several errors, including finger shape output error for sensor readings. The sensor response time is average when the tool is turned on for approximately 20 seconds. Acknowledgments The authors are grateful to Directorate of Research and Community Service (DRPM) Ministry of Research, Technology and Higher Education Republic of Indonesia in providing a grant to conduct this research. References [1] Smeltzer S C and Bare B G 2005 Buku Ajar Keperawatan Medisal Bedah Edisi 8 (Jakarta: ECG. Harold S. Koplewich) [2] Tavakoli M, Turicchia L and Sarpeshkar R 2010 An ultra-low-power pulse oximeter implemented with an energy-efficient transimpedance amplifier Biomedical Circuits and Systems, IEEE Transactions On vol 4 no 1 pp 27-38 [3] Bimbaum S 2009 Pulse oximetry: identifying its applications, coding, and reimbursement American College of Chest Physicians vol 135 pp 838-41 [4] Mendelson Y 2002 Non-invasive pulse oximetry utilizing skin reflectance photoplethysmography Biomedical Engineering, IEEE Engineering in Medicine and Biology Society vol 35 no 10 pp 798-805 [5] Lin J S, Huang S Y, Pan K W and Liu S H 2009 A physiological signal monitoring system based on an SoC platform and wireless network technologies in homecare technology Journal of Medical and Biological Engineering vol 29 pp 47-51 [6] Beattie Z T 2008 Algorithm for automatic beat detection of cardiovascular pressure signals Engineering in Medicine and Biology Society, 30th Annual International Conference of the IEEE pp 2594 7 4