Are Portable Imaging Intraoperative Radiographs Helpful for Assessing Adequate Acetabular Cup Positioning in Total Hip Arthroplasty?

Similar documents
Disclosure. Direct Anterior THA via Extension Table. History 11/3/2015

Transverse Acetabular Ligament A Guide Toacetabular Component Anteversion

Navigation for total hip arthroplasty

Reliability and validity of measuring version of the acetabular component

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Dissociation of Polyethylene Liner of the Dual Mobility Acetabular Component after Closed Reduction of Dislocation: A Case Report

Functional safe zone. Safe zone

Case Report Anterior Subluxation after Total Hip Replacement Confirmed by Radiographs: Report of Two Cases

Computer Aided Evaluation of Total Hip Prosthesis Stability

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Plain radiographs remain the primary skeletal imaging

Optimum implant geometry

The Spatial Location of Impingement in Total Hip Arthroplasty

Measuring the Impact of Femoral Head Size on Dislocation Rates Following Total Hip Arthroplasty

Poor accuracy of freehand cup positioning during total hip arthroplasty

CLINICAL PAPER / ORTHOPEDIC

Increased Rate Of Dislocation Of Total Hip Arthroplasty With Cementless Implants: Accuracy Of Acetabular Inclination.

Total Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner

Cup Alignment Error Model for Total Hip Arthroplasty

HIP SYSTEM SURGICAL TECHNIQUE

Influences of head/neck ratio and femoral antetorsion on the safe-zone of operative acetabular orientations in total hip arthroplasty

The Influence of Spinal Deformities on Acetabular Orientation in Total Hip Arthroplasty

ACETABULAR CUP SURGICAL TECHNIQUE

Galileo Positioning System

Research Article Clinical Validation of Computer-Assisted Navigation in Total Hip Arthroplasty

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

TaperFill. Surgical Technique

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Orthopedic Surgery (Adult Hip Service) (Seoul National University Hospital)

Are You Living with. Hip Pain? MAKOplasty may be the right treatment option for you.

Measurement of the Acetabular Cup Anteversion on Simulated Radiographs

Is the cup orientation different in bilateral total hip arthroplasty with right-handed surgeons using posterolateral approach?

Revision Total Hip Arthroplasty Using Tantalum Augment in Patients with Paprosky III or IV Acetabular Bone Defects: A Minimum 2-year Follow Up Study

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Bone Bangalore

Reliability of Simple Radiographic Parameters for Pincer FAI

Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

Preoperative Planning. The primary objectives of preoperative planning are to:

Operative Technique Crown Cup Acetabular System

Bilaterally primary cementless total hip arthroplasty in patients with ankylosing spondylitis

Bone Preservation Stem

Manza Cup HA SURGICAL TECHNIQUE.

DISLOCATION OF TOTAL HIP PROSTHESES*

CONGENITAL HIP DISEASE IN YOUNG ADULTS CLASSIFICATION AND TREATMENT WITH THA. Th. KARACHALIOS, MD, DSc PROF IN ORTHOPAEDICS

DURALOC. Acetabular Cup System. Surgical Technique

Range of Motion After Total Hip Arthroplasty: Experimental Verification of the Analytical Simulator

Continuing the Tradition. VerSys Heritage Hip System

Signature Personalized Patient Care

PMMA Spacer. X-ray Marker

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

Cementless femoral stem type SF

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

PRODUCT RATIONALE & SURGICAL TECHNIQUE

Robotic-Arm Assisted Surgery

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

pact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Comparison of navigation accuracy in THA between the mini-anterior and -posterior approaches

Acetabular Center Axis: Is It the Future of Hip Navigation?

This is a repository copy of The impact of surgeon handedness in total hip replacement.

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe

Effect of Superior Placement of the Hip Center on Abductor Muscle Strength in Total Hip Arthroplasty

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Your Pre-operative Guide

Stability without compromise. Epsilon Durasul Constrained Insert

Metha Short Hip Stem System

Product Information. *smith&nephew POLARCUP Dual Mobility System

THE DEFINITION AND MEASUREMENT OF

Optimizing function Maximizing survivorship Accelerating recovery

Surgical Technique r5.indd 1 12/8/10 10:36 AM

The role of the transverse acetabular ligament in total hip arthroplasty

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)

Ovation Hip System. Surgical Technique

An Investigation into the Dynamic Loading of Ceramic-on-Ceramic Total Hip Replacements and its Relevance to Squeaking

Repeated Ceramic Head Fracture after Ceramic-on-ceramic Total Hip Arthroplasty

The Treatment of Pelvic Discontinuity During Acetabular Revision

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

ARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear

CLS Brevius Stem with Kinectiv Technology

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Recently, the new generation of metal-on-metal total hip resurfacing. arthroplasty is well known for preserving the proximal femoral bone stock,

Association between Sacral Slanting and Adjacent Structures in Patients with Adolescent Idiopathic Scoliosis

Cemented femoral stem - type CSC

TOTAL HIP REPLACEMENT:

CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Socket wall addition device in the treatment of recurrent hip prosthesis dislocation

Clinical and radiological results of the stemmed Mc Minn cup in hip revision surgery

Dual Mobility System Evaluation surgical technique

3A ODEP rating, demonstrating 99.5% survivorship at 3 years for aseptic loosening

Dual Mobility System Surgical technique

PAL Pelvic Alignment Level

Failure to correct femoral anteversion on the AP Pelvis radiograph leads to errors in prosthesis selection in total hip arthroplasty

Transcription:

J Korean Med Sci 2009; 24: 315-9 ISSN 1011-8934 DOI: 10.3346/jkms.2009.24.2.315 Copyright The Korean Academy of Medical Sciences Are Portable Imaging Intraoperative Radiographs Helpful for Assessing Adequate Acetabular Cup Positioning in Total Hip Arthroplasty? Despite advances in surgical techniques and instrumentation, current intra-operative estimations of acetabular version in total hip arthroplasty are of limited accuracy. In the present study, two experienced orthopedic surgeons compared intra-operatively measured (using portable imaging) anteversions and vertical inclinations of acetabular components with those measured using standardized s postoperatively in 40 patients. Of the all vertical inclinations measured from intra-operative s, 72.5% (n=29) were within ±2, and 97.5% (n=39) were within ±5 of those determined using post-operative s, and for anteversion, 52.5% (n=21) were within ±2, and 97.5% (n=39) were within ±5. Post-operative s demonstrated that 90.0% (n=36) of vertical inclinations and anteversions were within the adequate zone. Obviously, our method has its limitations, but the authors conclude that the method described in this article better allows surgeons to verify acetabular version intra-operatively. In particular, the described method is suitable in cases with a deformed acetabular anatomy and difficult revision surgery. Key Words : Arthroplasty, Replacement, Hip ; Acetabular Cup; Vertical Inclination; Anteversion Sang Won Park, Jong Hoon Park, Seung-Beom Han, Gi Won Choi, Dong Ik Song, and Eun Soo An Department of Orthopedic Surgery, Korea University College of Medicine, Seoul, Korea Received : 3 December 2007 Accepted : 29 June 2008 Address for correspondence Jong Hoon Park, M.D. Department of Orthopedic Surgery, Korea University Anam Hospital, 126-1 Anam-dong 5 ga, Seongbuk-gu, Seoul 136-705, Korea Tel : +82.2-920-6609, Fax : +82.2-924-2471 E-mail : pjh19642001@yahoo.co.kr INTRODUCTION It is widely accepted that acetabular component positioning is one of the most important success factors of total hip arthroplasty (1). Despite the many improvements that have been made in terms of the manufacture and design of ceramic implants, the ease with which ceramic component fractures occur is disappointing. Impingement of the femoral neck on the edge of the acetabular component is a well recognized mechanism of acetabular component fracture, and thus, the achievements of correct degrees of anteversion and vertical inclination of the acetabular component are more critical for ceramic-on-ceramic total hip arthroplasty than for polyethylene liner total hip arthroplasty (2). However, the intra-operative estimation of acetabular version in total hip arthroplasty is of limited accuracy and little information is available concerning the accuracy of component placement during the procedure. Thus, the purpose of this study was to evaluate whether portable s enable surgeons to assess acetabular cup version intra-operatively. MATERIALS AND METHODS A picture archiving communication system (PACS; Pi- ViewSTAR, Infinitt, Seoul, Korea) has been available at our hospital since March 2004. After its installation, intra-operative s became readily available and measurements of angles in s could be performed easily and accurately. Accordingly, we retrospectively reviewed the s of 40 patients who underwent cementless total hip arthroplasty (including one case of acetabular revision only) from March 2004 to December 2006. Radiographs that demonstrated a marked pelvic obliquity in pelvic anteroposterior (AP) view were excluded. There were 25 male and 15 female patients, and mean patient age at index operation was 54 yr (range, 31-86 yr) (Table 1). Patients were fitted with one of two acetabular components from one company (Ver- Sys, Zimmer, Warsaw, IN, U.S.A.), i.e., Trilogy AB (ceramic on ceramic articulation) or Trilogy (metal on polyethylene [PE] articulation). Twenty nine cases underwent ceramic on ceramic total hip arthroplasty and 11 metal on PE total hip arthroplasty. A posterolateral surgical approach was adopted in all cases, with the patient firmly anchored in a lateral decubitus position on the operating table. To achieve an adequate position, we sometimes estimated the bilateral symmetry of the obturator foramen in pelvic AP view using a C-arm image intensifier. During surgery, an alignment guide rod was used to determine the correct vertical inclination and anteversion of the acetabular prosthesis. Two surgeons specifically recruited for this study were asked to measure vertical inclinations and anteversions of acetabular cups using the intra-operative portable AP and lateral (Lat) views; these were later compared 315

316 S.W. Park, J.H. Park, S.-B. Han, et al. with post-operative standard s. Beneath the operating table at our hospital, there is a space for inserting an y cassette to obtain a hip Lat. view before operation. Thus, in each patient, after acetabular cup insertion had been achieved, a portable hip Lat. view was taken. Subsequently, both hip portable AP views were taken; we refer to these as initial portable s. When surgeons did not achieve a satisfactory acetabular cup position according to initial portable s, the acetabular cup concerned was extracted, reinserted, and its position rechecked, and when the position of an acetabular cup was agreed, we refer to these as the confirmed portable. Final postoperative s are referred to as post-operative standard s. The method used to obtain the intra-operative portable Lat. view differed from that used to obtain a postoperative Lat. view. Specifically, post-operative views were taken in the supine position and intra-operative views were taken in the lateral position. On portable Lat. view, an imaginary elliptical orbit and a line passing through the long axis of the elliptical orbit were drawn, and the angle between this line and the vertical line drawn from the surface of the earth was defined as anteversion (Fig. 1). Even though there are some argues about definition of an anteversion, we used plain s to measure anteversion in the present study. Table 1. Patient demographic information Number of patients 40 Gender (M/F) 25/15 Age Mean 54; range 31-86 Diagnosis AVN of femoral head 30 Post traumatic AVN 1 Secondary osteoarthritis 7 Femur neck fracture 1 Ankylosing spondylitis 1 Operation THA 39 Cup revision only 1 Vertical inclination was defined as the angle between the line joining the ischial tuberosities and the line through the long axis of the cup (Fig. 2). In the present study, we defined an adequate zone of vertical inclination as between 30 and 50 and an adequate zone of anteversion as between 5 and 30. These ranges taken from the literature (3), but the maximum anteversion angle set at 5 greater than literature value due to Korean life style. Inter-obsever correlations were evaluated using the intraclass correlation coefficients (), which provide a measure of the degree of agreement among raters. s range between 0.0 and 1.0, and a higher score indicates better agreement. RESULTS Differences between intra-operative and post-operative measurements of vertical inclination and anteversion were determined. For all measured vertical angles in intra-operative s, 72.5% (n=29) were within ±2 of postoperative standard s, 97.5% (n=39) were within ±5, and 2.5% (n=1) were over ±5 (Fig. 3). In terms of anteversion, 52.5% (n=21) were within ±2, and 97.5% (n=39) were within ±5 of values in post-operative standard s (Fig. 4). Among the safe cases (n=37, 92.5%) confirmed in portable s for vertical inclination, one case was found to be inadequate in post-operative standard s. In terms of anteversion, 95% (n=38) of cases had an adequate confirmed portable and two cases of them had an inadequate in post-operative standard. Finally, post-operative standard s demonstrated that 90% (n=36) of vertical inclinations and anteversions were within the adequate zone (Table 2). The mean inter-observer correlation between the two orthopedic surgeons was 0.96 and ranged from 0.73 to 0.98 (Table 3). AVN, avascular necrosis; THA, total hip arthroplasty. Fig. 1. The angle between the line passing through the long axis of the imaginary elliptical orbit and a vertical line from the bottom was defined as the angle of anteversion in intra-operative portable Lat view. Fig. 2. The angle between the line joining the ischial tuberosities and the line through the long axis of the acetabular cup was defined as the angle of vertical inclination in a portable pelvic AP view.

Intraoperative Portable Imaging in Total Hip Arthroplasty 317 5.0 6 4 2.5 F.I-C.P.I (degree) 0.0-2.5 F.A-C.P.A (degree) 2 0-2 -5.0-4 -7.5-6 35 40 45 50 55 F.I (degree) Fig. 3. Points represent vertical inclination differences between final post-operative standard s and confirmed portable s for each cup. F.I, Final Inclination; C.P.I, Confirmed Portable Inclination. Table 2. Components in each Initial portable Confirmed portable Postopertaive T, within the safe zone; F, out of the safe zone. DISCUSSION No of Vertical inclination/ anteversion (%) T T T 35 (87.5%)/34 (85%) T T F 1 (2.5%)/2 (5%) T F F 2 (5%)/1 (2.5%) F T T 1 (2.5%)/2 (5%) F F F 1 (2.5%)/1 (2.5%) Accurate positioning of the femoral and acetabular components is important for successful total hip arthroplasty (1). Correct component orientation is vital to prevent dislocation, reduce component wear, and provide a maximum range of motion (3-8). Moreover, these factors all contribute to arthroplasty survival and longevity and have significant implications on long-term clinical and economic outcomes of total hip arthroplasty. The importance of adequate acetabular cup positioning was emphasized after ceramic-on-ceramic articulations were introduced in total hip arthroplasty. According to Hassan et al. (7), despite advances in material manufacturing, concerns about component fracture remain. These workers found that impingement of the femoral neck on the edge of the acetabular component can cause acetabular component failure. Thus, acetabular cups must be oriented in an optimal cup position to minimize this risk of impingement. However, one practical problem encountered is that sockets 5 10 15 20 25 30 35 F.A (degree) Fig. 4. Points represent anteversion differences between final postoperative and confirmed portable s for each cup. F.A, Final Anteversion; C.P.A, Confirmed Portable Anteversion. Table 3. Inter-observer correlations between two orthopedic surgeons Mean of Minimum of Maximum of Vertical inclination Initial 0.96 0.90 0.98 Confirmed 0.93 0.87 0.96 Final 0.96 0.93 0.98 Anteversion Initial 0.96 0.90 0.98 Confirmed 0.86 0.73 0.93 Final 0.96 0.93 0.98, intraclass correlation coefficient. tend to revert when total hip arthroplasty is performed through a posterolateral approach. This is usually caused by inadequate anterior retraction of the femur, which forces the acetabular positioning device posteriorly during component insertion. Moreover, during cup fixing (particularly in terms of anteversion) the surgeon must be able to judge the position of the pelvis in both horizontal and vertical planes. Furthermore, errors associated with patient positioning on the operating table are a common cause of acetabular malpositioning, and although several jigs and guide rods have been devised to determine proper positioning, these instruments are not fool proof. Rather, they should be viewed as crude measuring devices that are subject to errors associated with patient positioning. Nonetheless, it is not uncommon for an orthopedic surgeon to be surprised by acetabular anteversion discrepancies shown by true lateral films obtained during follow up. Thus, despite the popularity of total hip arthroplasty, intra-

318 S.W. Park, J.H. Park, S.-B. Han, et al. Fig. 5. (A) The acetabular cup was 9 retroverted in the initial portable. (B) The reinserted cup was 18.5 anteverted in the confirmed portable. (C) The cup position was 16 anteverted in the post-operative standard. A B C operative estimations of acetabular version are of limited accuracy, and furthermore, little information is available concerning the accuracy of component placement. Several investigators have introduced techniques for measuring anteversion and vertical inclination on s. The first such study in total hip arthroplasty was conducted by McLaren, who used the wire ring in the Charnley-Muller prosthesis to calculate version (9). However, despite the presumed reliabilities of intra-operative assessments of vertical inclination and anteversion using the alignment guide, 42% of cups were still found to be outside the safe zone, as defined by Lewinnek et al. (3). In addition, Wines and McNicol (10) found that only 45% of acetabular components were within the expected clinical version range. In a study by Hassan et al. (7), vertical inclination was found to be reasonably assessable during surgery, but anteversion could not be accurately assessed during surgery, even using the alignment guide. In 1987, Cohn et al. (11) described a new technique for the intraoperative determination of acetabular anteversion using a plastic overlay. According to this study, obtaining a true lateral view of the hip intra-operatively is difficult, but overlays on easily obtained AP views allow the accurate assessments of degrees of anteversion. In this previous study, difficulty was encountered identifying the apex of the acetabular cup ellipse when measuring the acetabular anteversion angle, and this was particularly evident at higher degrees of version when the apex was more rounded. Moreover, although plain pelvic AP view can show some degree of acetabular cup rotation, it does not differentiate retroversion and anteversion. Thus, Cohn recommended that surgeons should not solely rely on this method, but rather use it to help verify acetabular position in difficult cases, when the anatomy is significantly distorted. It was also recommended that a in a second plane must be taken. Our method was driven by the necessity for a lateral view to determine the direction of version. According to our study, of all measured vertical inclinations in intra-operative s 97.5% were within ±5 as compared with post-operative standard s, and in terms of anteversion, 52.5% were within ±2, and 97.5% were within ±5. Moreover, post-operative s demonstrated that 90.0% of anteversions were within the adequate zone. Even though, some cases were found to be beyond the adequate range by post-operative y, we consider that the errors observed during this study fell into the clinically acceptable during follow up. When vertical inclination and anteversion were compared individually, intra-operative assessments of vertical inclination were found to be more reliable than those of anteversion, which occurs with the results of Hassan et al. Interestingly, one case in the present study showed 9 of retroversion in the initial portable, and the author extracted and reinserted the cup. Finally, the cup was positioned 16 anteverted (Fig. 5). It should be borne in mind that the detection of the retroverted state in AP. view is sometimes so difficult, in the present study, only lateral view visualized an inadequately retroverted position. It is evident that our method is not without shortcomings, as changes in pelvis flexion/extension will alter acetabular version, and thus, we do not consider that our method is routinely recommendable in normal cases. However, the combination of intra-operative AP and Lat views can allow surgeons to assess acetabular version intra-operatively. In particular, we recommend the described method in cases with a deformed acetabular anatomy and for difficult revision surgery. REFERENCES 1. Garcia-Cimbrelo E, Munuera L. Dislocation in low-friction arthroplasty. J Arthroplasty 1992; 7: 149-55. 2. Ha YC, Kim SY, Kim HJ, Yoo JJ, Koo KH. Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res 2007; 458: 106-10. 3. Lewinnek GE, Lewis JL, Tarr R, compere CL, Zimmerman JR. Dis-

Intraoperative Portable Imaging in Total Hip Arthroplasty 319 locations after total hip-replacement arthroplasties. J Bone Joint Surg Am 1978; 60: 217-20. 4. Carlsson AS, Gentz CF. Postoperative dislocation in the Charnley and Brunswik total hip arthroplasty. Clin Orthop Relat Res 1977; 125: 177-82. 5. D Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW Jr. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am 2000; 82: 315-21. 6. Eftekhar NS. Dislocation and instability complicating low friction arthroplasty of the hip joint. Clin Orthop Relat Res 1976; 121: 120-5. 7. Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT. Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty 1998; 13: 80-4. 8. Kummer FJ, Shah S, Iyer S, DiCesare PE. The effect of acetabular cup orientations on limiting hip rotation. J Arthroplasty 1999; 14: 509-13. 9. McLaren RH. Prosthetic hip angulation. Radiology 1973; 107: 705-6. 10. Wines AP, McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 2006; 21: 696-701. 11. Cohn BT, Katz MM, Krackow KA, Lennox DW, Loeb P. A new technique for the intraoperative determination of acetabular anteversion. Orthopedics 1987; 10: 1565-6.