Cloud Condensation Nuclei Counter (CCN) Module

Similar documents
General Single Ion Calibration. Pete 14-May-09

Sleep Apnea Therapy Software User Manual

Sleep Apnea Therapy Software Clinician Manual

Agile Product Lifecycle Management for Process

Dosimeter Setting Device

Hanwell Instruments Ltd. Instruction Manual

User Manual. RaySafe i2 dose viewer

Clay Tablet Connector for hybris. User Guide. Version 1.5.0

The University of Texas MD Anderson Cancer Center Division of Quantitative Sciences Department of Biostatistics. CRM Suite. User s Guide Version 1.0.

Table of Contents Index Next. See inside for a complete description of program functions >> Link to the Table of Contents >> Link to the Index

For Electric Personal Dosimete Dose-i

Software Version 2.0. User s Guide

AudioConsole. User Guide. Doc. No EN/01 Part No EN

Sanako Lab 100 STS USER GUIDE

Voxar 3D CardiaMetrix. Reference Guide

TRAINING MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

Symantec ESM Agent for IBM AS/400 Installation Guide. Version: 6.5

MODULE: SQUAT JUMP BRIEF DESCRIPTION:

Table of Contents. Contour Diabetes App User Guide

Contents of the Prodigy Pocket. Meter. PRODIGY Owner s Manual PRODIGY Owner s Manual

Proteome Discoverer Version 1.3

AVANT Audiometer Manual Rev. 2 Effective 10/05

Diabetes Management App. Instruction Manual

OneTouch Reveal Web Application. User Manual for Patients Instructions for Use

Titrations in Cytobank

MCC Human Machine lnterface

Table of Contents Index Next. See inside for a complete description of program functions >> Link to the Table of Contents >> Link to the Index

SANAKO Lab 100 STS USER GUIDE

TRAINING MANUAL AVANT HIT+ Hearing Instrument Test Chamber.

Directions for Use. CardioPerfect Webstation 2.0

Contour Diabetes app User Guide

Exercise 2: Effects of Cold Temperature Aim: To record changes in heart rate after the heart is bathed in cold Ringer s solution.

MedsCheck Reviews. Ontario

ProScript User Guide. Pharmacy Access Medicines Manager

Set Up SOS Video Chat and Screen-Sharing

LiteLink mini USB. Diatransfer 2

LabVIEW PROFIBUS VISA Driver DP-Master

Allergy Basics. This handout describes the process for adding and removing allergies from a patient s chart.

INSTRUCTOR WALKTHROUGH

iworx Sample Lab Experiment AN-5: Cockroach Leg Mechanoreceptors

Chronic Pain Management Workflow Getting Started: Wrenching In Assessments into Favorites (do once!)

LabVIEW Profibus VISA Driver DP-Slave

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

Cigarette Smoke Generator

Vaccination Setup. Immunization Set Up & Reporting

Lionbridge Connector for Hybris. User Guide

Dosimeter Setting Device System NRZ

Practical Guidelines For the Enraf-Nonius Commercial Training Myomed 632

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Technical Bulletin. Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch

Appendix B. Nodulus Observer XT Instructional Guide. 1. Setting up your project p. 2. a. Observation p. 2. b. Subjects, behaviors and coding p.

RELEASED. Clearing your active insulin

Epilepsy Sensor Transmitter

Release Notes. Medtech32. Version Build 3347 Update HbA1c Laboratory Data Format Change Advanced Forms Licensing Renewal (September 2011)

Bruker D8 Discover User Manual (Version: July 2017)

Software Version 1.0. User s Manual

ProSense 307/347/367 Reviewer's Guide

Thrive Hearing Control Application

Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Analysis Procedure. Rev

Graphical User Interface for Windows for MCM Module

NeuroLink by Applied Neuroscience, Inc. Help Manual Applied Neuroscience, Inc. Applied Neuroscience, Inc.

RELEASED. first steps. Icon Icon name What it means

icap Monitor User Manual EEG Enterprises, Inc. 586 Main Street Farmingdale, New York TEL: (516) FAX: (516)

Dementia Direct Enhanced Service

LabVIEW PROFIBUS VISA Driver DP-Slave

Biopac Student Lab Lesson 3 ELECTROENCEPHALOGRAPHY (EEG) I Analysis Procedure. Rev

Kofax VRS. Installation Guide

iworx Sample Lab Experiment HH-4: The Six-Lead Electrocardiogram

REQUIREMENTS SPECIFICATION

Attenti One-Piece Tracking Device 4

AMBCO 2500 AUDIOMETER SYSTEM WITH FIVE YEAR WARRANTY

Nitelog. User Manual. For use with the Z1 Auto CPAP System

Software license... 2 Quick Start Guide... 4

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

Report Reference Guide

Fully Automated IFA Processor LIS User Manual

Weight And Body Fat! Why do I lose weight but my body fat doesn t change much? Scales by How does it work? Is it accurate?

iworx Sample Lab Experiment HC-3: Pulse Wave Velocity

Warning: Avoid putting the tip of the syringe needle too deeply into the hole to avoid damage to the heart tissue.

SPECIAL DISCLAIMER FOR INTERPRETING SERVICES INVOLVING CALLS TO EMERGENCY SERVICE PROVIDERS (911/E911), OR LEGAL, MEDICAL OR MENTAL HEALTH ISSUES

1724 Lab: Frog Skeletal Muscle Physiology (Marieb Exercise 16A) Marieb/iWorx / Ziser, 2002

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

TRAINING MANUAL. MedRx TINNOMETER. Revolutionary Tinnitus Assessment.

The Hill s Healthy Weight Protocol User Guide. Effective

IMPORTANT!!! Please read the FAQ document BEFORE you step through this tutorial.

Documenting Patient Immunization. Ontario 2018/19

SleepImage Website Instructions for Use

Experiment HH-2: The Electrocardiogram and Heart Sounds

FT-302 Force Transducer

SHORETEL APPLICATION NOTE

OWL+USB SOFTWARE USER GUIDE

Anticoagulation Manager - Getting Started

Data Management System (DMS) User Guide

Getting you up to speed Quick Reference Guide

MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

The Clinical Information Data Entry Screen is the main screen in the DQCMS application.

Transcription:

Particle Analysis and Display System (PADS): Cloud Condensation Nuclei Counter (CCN) Module Operator Manual DOC-0190 A-1 PADS 2.5.6, CCN Module 2.5.1 5710 Flatiron Parkway, Unit B Boulder, CO 80301 USA C O P Y R I G H T 2 0 0 9 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I N C.

Copyright 2009 Droplet Measurement Technologies, Inc. 5710 FLATIRON PARKWAY, SUITE B BOULDER, COLORADO, USA 80301 TEL: +1 (303) 440-5576 FAX: +1 (303) 440-1965 WWW.DROPLETMEASUREMENT.COM All rights reserved. DMT licenses PADS software only upon the condition that you accept all of the terms contained in this license agreement. Each PADS license you purchase allows you to acquire data on one computer only. Data can be viewed in playback mode on an unlimited number of computers. This software is provided by DMT as is and any express or implied warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose are disclaimed. Under no circumstances and under no legal theory, whether in tort, contract, or otherwise, shall DMT or its developers be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including damages for work stoppage; computer failure or malfunction; loss of goodwill; loss of use, data or profits; or for any and all other damages and losses). Some states do not allow the limitation or exclusion of implied warranties and you may be entitled to additional rights in those states. Trademark Information All Droplet Measurement Technologies, Inc. product names and the Droplet Measurement Technologies, Inc. logo are trademarks of Droplet Measurement Technologies, Inc. All other brands and product names are trademarks or registered trademarks of their respective owners. Form DOC-0190 Rev A-1 II

C O N T E N T S 1.0 Introduction... 4 2.0 Configuration... 4 Configuring the CCN... 4 Configuring the CCN Display... 7 3.0 The CCN Window... 8 Channel Data... 8 Histogram Data Window... 9 Chart Displays... 9 Appendix A: CCN Channels... 13 L i s t o f F i g u r e s Figure 1: CCN Configuration Editor Window... 5 Figure 3: CCN Display Editor Window... 7 Figure 4: CCN Data Window... 8 Figure 5: CCN Histogram Display... 9 Figure 6: CCN Standard Time-Series Charts... 10 Form DOC-0190 Rev A-1 I II

1.0 Introduction The Particle Analysis and Display System (PADS) is a software package that interfaces with instruments produced by Droplet Measurement Technologies (DMT) and other leading instruments used in the atmospheric sciences. This manual describes the PADS module for the Cloud Condensation Nuclei Counter (CCN). For an explanation of the basic PADS setup and instructions on how to acquire data using PADS, consult the PADS Operator Manual. Definitions and calculations used in the CCN module are also described in the PADS Operator Manual. 2.0 Configuration Using PADS, you can configure both the software for the instrument and the instrument s data display in PADS. The following two sections explain how to do this. Configuring the CCN Your CCN and data system should arrive preconfigured from DMT. In some cases, however, you may want to change the software configuration for the instrument. To do this, follow the steps below. Note: Droplet Measurement Technologies STRONGLY recommends that customers contact our office prior to changing any of the parameters in the instrument configuration. Improper changes can result in communication failure and/or changes in PADS computation algorithms, which can compromise data validity. 1. Click on the CCN tab. 2. From the Configure menu, select Configure Instrument. You will see the following window. Form DOC-0190 Rev A-1 4

Figure 1: CCN Configuration Editor Window 3. Now you can configure the instrument parameters to your desired specifications. You will find a list of the parameters you may want to reconfigure in the two sections below, Occasionally Reconfigured CCN Parameters and Rarely Reconfigured CCN Parameters. If at any time you would like to revert to the previously saved values for the CCN parameters, press Cancel to exit the window without saving changes. 4. When you are done configuring the CCN parameters, press Save at the top of the Config editor window. (If you would instead like to revert to the previously saved values, click Cancel.) Then press the green Reset Program button for the new configuration to take effect. Note that pressing the Reset Program button will clear any data currently being displayed. Occasionally Reconfigured CCN Parameters Sample Time: Since the CCN relays particle data at one-second intervals, this parameter should always be set to 1 sec / 1 Hz. Form DOC-0190 Rev A-1 5

At Startup Enabled / Disabled: If you want the CCN to acquire data when PADS begins sampling, make sure this parameter is in the Enabled mode. In some cases, such as if the CCN is inoperative, you may want to use this control to disable the probe. Disabling the CCN allows data to transmit from other instruments without interference. COM Port: This is the serial communications port that the CCN uses to connect with the computer. This number should match the computer hardware configuration for the particular computer you are using. If you are not using multiple computers, this number should not be changed. You will notice that there are other parameters listed on the CCN Config Editor window. You should not need to change these, and changing them may compromise your data. If you are curious about these parameters or think you do need to modify them, see the section titled Rarely Reconfigured CCN Parameters below or consult with a DMT technical representative. Rarely Reconfigured CCN Parameters The CCN configuration editor displays several parameters that you will rarely need to modify. The following is a list of these parameters and an explanation of what they do. Instrument #: This lists the number corresponding to the instrument you are viewing, in this case the CCN. If your CCN has been assigned instrument number one, you will see 1 in this field. You should not need to modify the instrument number, and in fact you are unable to do so from within PADS. Baud Rate: The Baud rate for the probe is defined at manufacture, and you should not need to change it. PADS lists this parameter because some probes can run at different baud rates. So if you reconfigure your hardware, the baud rate may change. In general, a higher baud rate means that the probe can transmit data more quickly to the computer. However, higher baud rates may not work with some computers and can result in unreliable data transmission. After making changes in the instrument configuration window, you will need to press the Save button and then click the green Reset Program to activate these changes. Clicking Reset Program will clear any data PADS is currently displaying. Form DOC-0190 Rev A-1 6

Configuring the CCN Display To configure the CCN display, click on the CCN tab if you have not already done so. Then select Configure from the menu bar and click on Configure Display. This will bring up the following window. Figure 2: CCN Display Editor Window You do not need to modify the Display # or Instrument #. Changing the Refresh Time allows you to set the time intervals for data display during acquisition mode; you can choose any time that is equal to or greater than the sample time. (Choosing a time less than the sample time is not useful, since the same data will be displayed multiple times.) The CCN Display Parameter box at the bottom of the window also allows you to configure the channels on the CCN s selectable graphs. To change these channels, click on the arrow buttons to scroll between available options for the channels. You can also click on the white fields to bring up a list of all the available options, from which you can then choose the channel you want. When you are done, click on Save to update the configurations or Cancel to revert to the previous configuration. After you reset PADS, you will be able to see any changes. Note that clicking Reset Program will clear out any data currently being displayed. Form DOC-0190 Rev A-1 7

Configuring channels in the Display Editor will change the display upon start-up. Once PADS has started, you can select any channels to be displayed in the selectable charts. See the Chart Displays section for more information. 3.0 The CCN Window The different parts of the CCN Window are discussed below. For explanations of the Enable button, COM Port indicator, and Fault/No Fault button, see the Instrument Tabs section of the PADS Operator Manual. Channel Data The CCN channels are displayed in the data window at the upper left of the CCN tab. These data are specific to the time listed in the upper-right of the PADS window. For information on specific channels, their definitions, and their acceptable ranges, consult Appendix A: CCN Channels and the PADS Operator Manual s Appendix A: Definitions. Figure 3: CCN Data Window Form DOC-0190 Rev A-1 8

Note that sample and sheath flow are labeled with cm 3 units, although these channels are really given in cm 3 /min. This is a known bug that will be fixed in an upcoming version of PADS. Histogram Data Window Figure 4 shows the histogram display of CCN-acquired particle data. Like the channel data display, the histogram shows time-specific data. Figure 4: CCN Histogram Display The button to the upper right of the histogram allows you to change the appearance of the histogram display. Click on the button to bring up a drop-down list of available options. Right-clicking on the histogram itself will also show you options for scaling and copying data. For more information, see the discussion of time-series charts in the Chart Displays section. Chart Displays The CCN chart displays consist of a tab with three standard time-series charts and a tab with two selectable charts. Figure 5 shows these tabs and the standard time-series charts. Form DOC-0190 Rev A-1 9

Figure 5: CCN Standard Time-Series Charts When you access time-series charts in playback mode, the currently selected moment in time is indicated by a yellow cursor, as shown above. The y-axis value for this time is indicated by cross (+) on this cursor. Note that when you display a large range of timeseries data, the chart display does not have sufficient resolution to display each individual time point. To increase resolution, zoom in on the data by changing the time interval to a smaller range. On all the charts with x and y axes, you can change the scale by typing a different number into the starting and ending values on each axis. For instance, if you want to change the time period in one of the graphs above to end at 13:00:00, you simply select the field that currently says 13:25:13, type in 13:00:00, and hit the <Enter> key. In Form DOC-0190 Rev A-1 10

acquisition mode, you must disable autoscaling (see below) before you modify fields in this way. Many charts also show you options for scaling and copying the data when you right-click on them, which brings up a drop-down menu. These options are as follows: Autoscale This autoscales the relevant axis. In autoscaling mode, the minimum and maximum values of the axis are set automatically so that all data points can be seen in the display. Note that on charts that have autoscale buttons, like the large histogram chart on some instrument tabs, the buttons override the Autoscale options in the drop-down menu. To see autoscaling options in the drop-down menu, position the cursor over the relevant axis before right-clicking. Note that you may not always be able to autoscale the x-axis. Copy Data This copies the chart to the clipboard using a screen capture. This chart can then be pasted into other documents like Word or PowerPoint presentations. Export Simplified Image This copies a simplified image of the data to the clipboard or an output file. You can choose the format you desire bitmap (.bmp), encapsulated postscript (.eps), or enhanced metafile (.emf). Note that when you select the.eps option, you must copy the data to a file. Unless you specify otherwise, output files will be saved in the time-and-date-specific output file directory for the current session. Clear Graph This erases the currently displayed data points from the graph. More information about each of the tabs on the chart displays section is given below. 1. CCN # Conc, Flows, and Temperature Data The three charts on the first tab graph key CCN data with respect to time. The top chart displays particle number concentration (#/cm 3 ). The middle chart displays sample flow, sheath flow, and total flow (all in ccm). The bottom chart displays various temperature data. For definitions of these channels, see Appendix A in the PADS Operator Manual. In playback mode, you can zoom in or out by using the time controls. In acquisition mode, use the Display Range control to zoom in or out. The buttons to the right of the charts that look like this allow you to manipulate the chart display. Form DOC-0190 Rev A-1 11

2. Selectable Charts The CCN Selectable Charts tab displays two charts with user-specified channels plotted as a function of time. To change the channels plotted in the selectable charts, you have two options: 1.) To change the charts for the current session only, click on the CCN Selectable Charts tab and use the control in the upper left of the chart to select the channel you desire. You can either click on the text control to the right, which brings up a selectable list of channels, or you can use the button on the left to scroll between channels. 2.) To change the channels shown in the chart s display when PADS starts, go to the Configure menu, select Configure Display, and choose the desired channel. Then press the Reset Changes button to apply this configuration. Form DOC-0190 Rev A-1 12

Appendix A: CCN Channels A list of CCN channels appears below. The CCN output file will contain data values for each channel for each sampling instance. You can also plot each of these channels against time using the CCN Selectable Charts tab. For definitions of the channels, consult Appendix A: Definitions in the PADS Operator Manual. Time ADC overflow Hours Bin 1 Minutes Bin 2 Seconds Bin 3 SS setting Bin 4 Temp Stable? Bin 5 T1 read (C) Bin 6 T2 read (C) Bin 7 T3 read Bin 8 Sample Temp Bin 9 T inlet (C) Bin 10 T OPC (C) Bin 11 T Nafion (C) Bin 12 Sample flow (ccm) Bin 13 Sheath flow (ccm) Bin 14 Abs Press (mb) Bin 15 Laser Current (ma) Bin 16 1st Stage Monitor Bin 17 Temp. Gradient (C) Bin 18 Prop. Valve (V) Bin 19 Alarm Code Bin 20 Bin setting CCN Status # Conc GPS Time CCN channels fall into several broad categories: Time Channels: The time channels store time data. Time is generated by the PADS computer clock and is the time when the program receives the CCN data. It is given in seconds after midnight on the day the program was started. Hours, Minutes, and Seconds are generated by the CCN computer clock. They give the time in seconds after midnight when the CCN sends the data. GPS Time is included in every instrument s list of channels whenever a GPS is included as one of the PADS instruments. GPS Time is collected from Form DOC-0190 Rev A-1 13

an instrument other than the CCN, even though it appears as a channel in the CCN output file. Bin Channels: Channels labeled Bin [i] store data on the number of particles of different sizes that the CCN has detected. These data are used in the histogram display. Housekeeping channels: The CCN has 16 A/D housekeeping channels that measure a 0-5 V value from one of the instrument s internal sensors, for example a pressure or temperature sensor, and then convert this voltage to a binary value from 0 to 4095. These housekeeping channels often store information about the health of the instrument. In the list above, housekeeping channels are denoted in italics. Statistical Channels: ADC Overflow stores the number of oversized particles the probe has detected. SS Setting and Bin Setting store information about the CCN s configuration. In a future version of PADS, CCN Status will store information on the communication between the probe and PADS. Currently, the channel is non-functional. Calculated Channel: # Conc stores the result of a concentration calculation the CCN computer has performed. Form DOC-0190 Rev A-1 14