Method Development and Validation for the Estimation of Saroglitazar in Bulk and Pharmaceutical Dosage Form by RP-HPLC

Similar documents
RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

DEVELOPMENT AND VALIDATION OF NEW HPLC METHOD FOR THE ESTIMATION OF PALIPERIDONE IN PHARMACEUTICAL DOSAGE FORMS

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

Pelagia Research Library

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

VALIDATED RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF DEXAMETHASONE AND GRANISETRON IN COMBINED DOSAGE FORMS

International Journal of Medicine and Pharmaceutical Research. International Journal of Medicine and Pharmaceutical Research

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

J Pharm Sci Bioscientific Res (4): ISSN NO

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

Pelagia Research Library

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF FEBUXOSTAT IN BULK AND TABLET DOSAGE FORM

Estimation of Emtricitabine in Tablet Dosage Form by RP-HPLC

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BACLOFEN IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

DEVELOPMENT AND VALIDATION OF NOVEL HPLC METHOD FOR THE ESTIMATION OF DASATINIB IN BULK AND PHARMACEUTICAL DOSAGE FORMS

ISSN (Print)

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

36 J App Pharm Vol. 6; Issue 1: 36-42; January, 2014 Rao et al., 2014

Available online Research Article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

Available online at Scholars Research Library

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

A stability indicating RP-HPLC method for simultaneous estimation of darunavir and cobicistat in bulk and tablet dosage form

International Journal of Pharma and Bio Sciences

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

Stability indicating RP-HPLC method development and validation of Etizolam and Propranolol hydrochloride in pharmaceutical dosage form

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

Scholars Research Library

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

Rao and Gowrisankar: Stability-indicating RP-HPLC Method for Pseudoephedrine, Ambroxol and Desloratadine

Stress Degradation Studies And Validation Method For Quantification Of Aprepitent In Formulations By Using RP-HPLC

Estimation of zolmitriptan by a new RP-HPLC method

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

Development and validation of related substances method for Varenicline and its impurities

SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

Development of a Validated RP-HPLC Method for the Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

Method Development and Validation for Simultaneous Estimation of Atorvastatin and Ezetimibe in Pharmaceutical Dosage Form by HPLC

Journal of Chemical and Pharmaceutical Research

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical dosage form

NOVEL RP-HPLC METHOD. B.Lakshmi et a. concentration range KEY INTRODUCTION. Diltiazem is used to. . It works by of contractionn of the. (dilate).

Simple and stability indicating RP-HPLC assay method development and validation lisinopril dihydrate by RP-HPLC in bulk and dosage form

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

VALIDATED RP-HPLC METHOD FOR THE ESTIMATION OF MESALAMINE IN BULK AND TABLET DOSAGE FORM

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Isocratic Reversed Phase Liquid Chromatographic Method Validation for the Determination of Cilostazol in Pure and Formulations

International Journal of Pharma and Bio Sciences

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (6): (

New RP-HPLC Method for the Determination of Fludarabine in Pharmaceutical Dosage Forms

REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS

Development and validation of RP-HPLC method for simultaneous estimation of gliclazide and metformin in pure and tablet dosage form

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF ETORICOXIB AND THIOCOLCHICOSIDE IN PHARMACEUTICAL DOSAGE FORMS

World Journal of Pharmaceutical Research

Corresponding Author:

Comparative study of analytical method development of fluconazole in tablets and capsule by ultraviolet spectrophotometric method


Volume 2 (6), 2014, Page CODEN (USA)-IJPRUR, e-issn: International Journal of Pharma Research and Health Sciences

Quantitative estimation of Rosuvastatin in bulk and tablet dosage form by using area under curve method

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

Sujatha and Pavani et.al. Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

Research Article Derivative Spectrophotometric Method for Estimation of Metformin Hydrochloride in Bulk Drug and Dosage Form

ANALYTICAL TECHNIQUES FOR THE QUALITY OF ANTI- AIDS DRUGS

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR CILOSTAZOL IN TABLET DOSAGE FORM

Journal of Pharmacreations

Available online Research Article

Introductionn Ilaprazole (ILA) is

Pankti M. Shah et al, Asian Journal of Pharmaceutical Technology & Innovation, 04 (17); 2016; 07-16

SIMULTANEOUS QUANTIFICATION OF TELMISARTAN AND METOPROLOL SUCCINATE IN TABLETS BY LIQUID CHROMATOGRAPHY

Research Article. ISSN Available online at 746

Development and Validation of RP-HPLC Method for the Estimation of Rosuvastatin Calcium and Niacin in Combined Tablet Dosage Form

DETERMINATION OF LOTEPREDNOL ETABONATE AND TOBRAMYCIN IN COMBINED DOSAGE FORM USING RP-HPLC METHOD

Scholars Research Library

Method Development and Validation for Simultaneous Estimation of Atenolol and Nifedipine in Pharmaceutical Dosage Forms by RP-HPLC

Validated Spectrophotometric Method for Simultaneous Estimation of Atorvastatin and Nicotinic acid in Combined Pharmaceutical dosage form

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON

S. G. Talele, D. V. Derle. Department of Pharmaceutics, N.D.M.V.P. College of Pharmacy, Nashik, Maharashtra, India

Research Article Simultaneous Estimation of DL-Methionine and Pyridoxine Hydrochloride in Tablet Dosage Form by RP-HPLC

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR DETERMINATION OF ROSUVASTATIN CALCIUM IN BULK AND PHARMACEUTICAL DOSAGE FORM

Research Article DEVOLOPMENT OF RP-HPLC METHOD AND IT S VALIDATION FOR SIMULTANEOUS ESTIMATION OF SITAGLIPTIN AND METFORMIN

Vol-3, Issue-4, Suppl-2, Nov 2012 ISSN: Sheth et al PHARMA SCIENCE MONITOR

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Analytical Method Development and Validation for the Estimation of Guaifenesin and Dextromethorphan by RP-HPLC

Transcription:

Original Research Method Development and Validation for the Estimation of Saroglitazar in Bulk and Pharmaceutical Dosage Form by RP-HPLC Hanumantha Rao K 1, Lakshmana Rao A 2,*, Chandra Sekhar KB 3 1 Assistant Professor, Department of Pharmacy, Krishna University, Machilipatnam, A.P., India. 2 Professor and Principle, V. V. Institute of Pharmaceutical Sciences, Gudlavalleru, A.P., India. 3 Professor, Department of Chemistry, JNTUA, Anantapuramu, A.P., India. * Corresponding Author: E-mail: dralrao@gmail.com ABSTRACT A simple, rapid, precise and accurate RP-HPLC method was developed and validated for the determination of Saroglitazar in tablet dosage form. Separation of the drug was achieved on a Kromasil C18 Column (150 mm x 4.6 mm I.D., 5 µm particle size). The method showed a linear response in the concentration range of 10-60 μg/ml using 0.1% orthophosphoric acid buffer:acetonitrile as the mobile phase in the ratio of 45:55 v/v with detection at 295 nm with a flow rate of 1 ml/min and retention time was 3.430 min. The method was validated as per the ICH guidelines. The method was successfully applied for routine quality control analysis of Saroglitazar in tablet dosage form. Keywords: Saroglitazar, estimation, UV detection, dosage form. INTRODUCTION Saroglitazar (Figure 1) is a drug for the treatment of type 2 diabetes mellitus, dyslipidemia and hyper triglyceridemia 1-3. Chemically, it is (2S)-2- Ethoxy-3-[4-(2-{2-methyl-5-[4-(methyl sulfanyl)phenyl]-1h-pyrrol-1-yl}ethoxy)phenyl] propanoic acid 4. In clinical studies, Saroglitazar has demonstrated reduction of triglycerides, LDL cholesterol, VLDL cholesterol, non-hdl cholesterol and an increase in HDL cholesterol 5. It has also shown favorable glycemic control by reducing the fasting plasma glucose and HBA 1c in diabetes patients. Saroglitazar is novel first in class drug which acts as a dual PPAR agonist at the subtypes α (alpha) and γ (gamma) of the peroxisome proliferator-activated receptor (PPAR) 6. Agonist action at PPARα lowers high blood triglycerides, and agonist action on PPAR γ improves insulin resistance and consequently lowers blood sugar 7. Literature survey revealed that few analytical methods such as UV 8,9, HPLC 10,11 and HPTLC 12 methods were reported for the determination of Saroglitazar in pharmaceutical dosage form. Hence the objective of the proposed method is to develop and validate a simple, rapid and accurate HPLC method in accordance with ICH guidelines 13 for the determination of Saroglitazar in bulk sample and its pharmaceutical formulation. MATERIALS AND METHODS Chemicals and reagents: The standard bulk drug sample of Saroglitazar was provided as gift sample from Spectrum Pharma Research Solutions, Hyderabad, India. The market formulation LIPAGLYN tablets (Saroglitazar 4 mg) were procured from local market. HPLC grade acetonitrile and water were purchased from E.Merck (India) Ltd, Mumbai, India. Orthophosphoric acid of AR grade was obtained from S.D. Fine Chemicals Ltd, Mumbai, India. Instrumentation: The analysis of drug Saroglitazar was carried out on a Waters HPLC system equipped with a reverse phase Kromasil C18 Column (150 mm x 4.6 mm I.D., 5 µm particle size), a 2695 binary pump, a 20 μl injection loop, auto sampler, a 2487 dual absorbance detector and running on Waters Empower 2 software. Chromatographic conditions: A mixture of 0.1% orthophosphoric acid buffer and acetonitrile as the mobile phase in the ratio of 45:55 v/v was found to be the most suitable mobile phase for ideal chromatographic separation of Saroglitazar. The solvent mixture was filtered through 0.45 μ membrane filter and sonicated before use. It was pumped through the column at a flow rate of 1.0 ml/min. Injection volume was 10 µl and the column was maintained at a temperature of 30 0 C. The column was equilibrated by pumping the mobile phase through the column for at least 30 minutes prior to the injection of the drug solution. Water and acetonitrile was used as diluent in the ratio of 50:50 v/v. The detection of the drug was monitored at 295 nm. The run time was set at 6 minutes. Preparation of stock and working standard solutions: 4 mg of Saroglitazar was accurately weighed, transferred to 10 ml volumetric flask and is dissolved in 7 ml of the diluent. Sonicate the solution for few minutes to dissolve the drug completely. Then it was filtered through 0.45 μ filter and the volume is made up to the mark with diluent to get a stock solution. Further pipetted 1.0 ml of the above stock solution into a 10 ml volumetric flask and Indian Journal of Pharmacy and Pharmacology, July - September 2015;2(3);150-154 150

diluted up to the mark with diluent to obtain required working standard concentrations of 10-60 μg/ml. Preparation of sample solution: Twenty commercial tablets of Saroglitazar were weighed and powdered. A quantity of the powder equivalent to 4 mg of Saroglitazar was accurately weighed, transferred to 10 ml volumetric flask and is dissolved in 7 ml of the diluent. Sonicate the solution for few minutes to dissolve the drug completely. Then it was filtered through 0.45 μ filter and the volume is made up to the mark with diluent. Further pipetted 1.0 ml of the above solution into a 10 ml volumetric flask and diluted up to the mark with diluent to obtain required concentrations of Saroglitazar in pharmaceutical dosage form. Inject 10 µl of the above solutions into the HPLC system and the chromatograms were recorded. All experiments were conducted in triplicate. METHOD VALIDATION The objective of the method validation is to demonstrate that the method is suitable for its intended purpose as it is stated in ICH guidelines. The method was validated for linearity, precision, accuracy, system suitability and specificity. Standard plots were constructed with six concentrations in the range of 10-60 μg/ml prepared in triplicates to test linearity. The peak area of Saroglitazar was plotted against the concentration to obtain the calibration graph. The linearity was evaluated by linear regression analysis that was calculated by the least square regression method. The precision of the assay was studied with respect to both system precision and method precision. The precision was calculated from six replicate injections of freshly prepared Saroglitazar test solution in the concentration value of 100% (40 μg/ml) of the intended test concentration value. Peak area of the Saroglitazar was determined and precision was reported as %RSD. Method accuracy was tested (% recovery of individual measurements) by analyzing sample of Saroglitazar at three different levels in pure solutions using three preparations for each level. The results were expressed as the percentage of Saroglitazar recovered in the samples. Linearity: Several aliquots of standard solution of Saroglitazar was taken in different 10 ml volumetric flasks and diluted up to the mark with diluent such that the final concentrations of Saroglitazar were in the linearity range of 10-60 µg/ml. Evaluation of the drug was performed with UV detector at 295 nm, peak area was recorded for all the peaks. The linearity results were shown in Table 1 and the calibration curve of Saroglitazar was shown in Figure 2. Precision: Precision is the degree of repeatability of an analytical method under normal operational conditions. Precision of the method was performed as system precision and method precision. To study the system precision, six replicate standard solutions of Saroglitazar was injected. The percent relative standard deviation (%RSD) was calculated. To study the method precision, six preparations from the same samples of Saroglitazar was injected and the %RSD were calculated. Results of precision studies were shown in Table 2. Accuracy: The accuracy of the method was assessed by recovery study of Saroglitazar in the dosage form at three different concentration levels. A fixed amount of preanalyzed sample was taken and standard drug was added at 50%, 100% and 150% levels. At each level, three determinations were performed. The concentration of Saroglitazar was calculated at different levels. The accuracy results were shown in Table 3. Limit of detection and limit of quantification: The limit of detection (LOD) and limit of quantification (LOQ) of the developed method were determined by injecting progressively low concentrations of the standard solution using the developed HPLC method. Ruggedness and robustness: The ruggedness of the method was determined by carrying out the experiment on different instruments by different operators using different columns of similar types. Robustness of the method was determined by making slight changes in the chromatographic conditions such as the composition of the mobile phase and flow rate of the mobile phase were altered and the chromatographic characteristics were evaluated. System suitability: System suitability parameters like retention time, theoretical plates and tailing factor were calculated and compared with standard values. Specificity: The specificity of the method was checked for the interference of impurities in the analysis of a blank solution (without any sample). Saroglitazar drug solution of 40 μg/ml was injected into the column, under optimized chromatographic conditions, to demonstrate the separation of from any of the impurities, if present. Analysis of Saroglitazar in tablet dosage form: 10 µl of Saroglitazar sample solution was injected and from the peak area of Saroglitazar, amount of drug in samples were computed. The assay results are furnished in Table 4. Indian Journal of Pharmacy and Pharmacology, July - September 2015;2(3);150-154 151

Fig. 1: Chemical structure of Saroglitazar Fig. 2: Calibration curve of Saroglitazar Fig. 3: Typical chromatogram of Saroglitazar standard Table 1: Linearity of Saroglitazar Linearity level Concentration (μg/ml) Area I 10 277874 II 20 538549 III 30 813776 IV 40 1060831 V 50 1314584 VI 60 1598781 Indian Journal of Pharmacy and Pharmacology, July - September 2015;2(3);150-154 152

Table 2: Precision studies of Saroglitazar Injection number System precision area Method precision area 1 958352 984075 2 956768 989787 3 964601 980649 4 960517 988127 5 957809 990253 6 953188 985748 Mean 958539 986440 SD 3820.9 3693.1 % RSD 0.4 0.4 % Concentration (at specification level) Table 3: Recovery studies of Saroglitzar Concentration added (μg/ml) Concentration found (μg/ml) % Recovery 50% 20 19.97 99.85% 100% 40 40.16 100.40% 150% 60 59.88 99.80% Mean recovery 100.01% Table 4: Analysis of Saroglitazar formulation Formulation Label claim Amount found % Assay Lipaglyn 4 mg 3.99 mg 99.75% Table 5: Chromatographic conditions of Saroglitazar Parameter Condition Mobile Phase Buffer:acetonitrile (55:45% v/v) Diluent Water:acetonitrile(50:50% v/v) UV detection 295 nm Analytical column Kromasil C18 column (150 x 4.6 mm, 5 ) Flow rate 1.0 ml/min Temperature 30 0 C Injection volume 10 l Run time 6.0 min Table 6: System suitability parameters of Saroglitazar Parameter Results λmax (nm) 295 Linearity range (μg/ml) 10-60 Correlation coefficient 0.9997 Retention time (min.) 3.430 Theoretical plates (N) 7073 Tailing factor 1.23 Limit of detection (μg/ml) 0.143 Limit of quantification (μg/ml) 0.434 RESULTS AND DISCUSSION The method was optimized with a view to develop an precise and accurate RP-HPLC method for determination of Saroglitazar in tablet dosage form using Kromasil C18 Column (150 mm x 4.6 mm I.D., 5 µm particle size) in isocratic mode with mobile phase composition of 0.1% orthophosphoric acid buffer and acetonitrile as the mobile phase in the ratio of 45:55 v/v. The use of above mobile phase resulted in peak with good shape and resolution. The flow rate was 1.0 ml/min and the drug component was measured with UV detector at 295 nm. The results of optimized chromatographic conditions were shown in Table 5. The response for the drug Saroglitazar was linear in the concentration range of 10-60 µg/ml. The regression equation was found to be y=26400x+8623.3 and correlation coefficient value of Saroglitazar was found to be 0.9997. The results show that an excellent correlation exists between peak area and concentration of drug within the concentration range indicated. The %RSD for system precision and method precision for Saroglitazar were found to be 0.4% and 0.4%, which are well within the acceptable criteria of not more than 2.0 and indicate the method is precise. The mean recovery of Saroglitazar was found to be 100.01% Indian Journal of Pharmacy and Pharmacology, July - September 2015;2(3);150-154 153

that shows there is no interference from excipients and indicate the method is accurate. The limit of detection and limit of quantification for Saroglitazar were found to be 0.143 µg/ml and 0.434 µg/ml, which indicate the sensitivity of the method. It was observed that there were no significant changes in the chromatograms, which demonstrated that the HPLC method so developed is rugged and robust. The retention time of Saroglitazar was 3.430 min. The number of theoretical plates was 7073 and tailing factor was 1.23 for Saroglitazar, which indicates efficient performance of the column. The summary of system suitability parameters were shown in Table 6. Typical chromatogram of drug Saroglitazar standard was shown in Figure 3. No interfering peaks were found in the chromatogram of the formulation within the run time indicating that excipients used in the formulation did not interfere with the estimation of the drug by the proposed HPLC method and hence the method was found to be specific and also confirmed with the results of analysis of formulation. Validated method was applied for the determination of Saroglitazar in commercial formulations. The % assay of Saroglitazar was found to be 99.75% of label claim of Saroglitazar. CONCLUSION A validated RP-HPLC method has been developed for the determination of Saroglitazar in tablet dosage form. The proposed method showed acceptable accuracy, precision, selectivity and wide linear concentration range. The results of analysis proved that the method is suitable for the determination of Saroglitazar in bulk and tablet dosage form and it is recommended for routine quality control analysis of the Saroglitazar in pharmaceutical formulation. with moderate PPARγ agonist activity in healthy human subjects. Clinical Drug Investigation. 2013; 33(11): 809-816. 8. Amin EH, Maheshwari DG. Development and validation of UV spectrophotometric method for Saroglitazar tablets. Journal of Pharmaceutical Science and Bioscientific Research. 2014; 4(5): 312-315. 9. Siddartha B, Sudheer Babu I. Method development and method validation of Saroglitazar in bulk and pharmaceutical dosage form by UV spectrophotometric method. Inventi Rapid: Pharm Analysis and Quality Assurance. 2014; July- September. 10. Siddartha B, Sudheer Babu I. Method development and validation for the estimation of Saroglitazar in bulk and pharmaceutical dosage form by RP-HPLC. World Journal of Pharmacy and Pharmaceutical Sciences. 2014; 3(9): 567-575. 11. Suresh Babu K, Ramu G, Rambabu C. Validated stability indicating RP-HPLC method development for the determination of Saroglitazar in bulk and pharmaceutical dosage form. Indo American Journal of Pharmaceutical Research. 2015; 5(3): 1255-1264. 12. Patel NM, Mehta FA, Shah DA, Chhalotiya UK. Development and validation of HPTLC method for estimation of Saroglitazar in bulk and pharmaceutical dosage form. Austin Journal of Analytical and Pharmaceutical Chemistry. 2015; 2(2): 1035-1038. 13. ICH Harmonised Tripartite Guideline, Q2(R1), Validation of analytical procedures: text and methodology. International Conference on Harmonisation, Geneva. 2005; 1-13. REFERENCES 1. https://en.wikipedia.org/wiki/saroglitazar 2. Joshi SR. Saroglitazar for the treatment of dyslipidemia in diabetic patients. Expert Opinion on Pharmacotherapy. 2015; 16(4): 597-606. 3. Shetty SR, Kumar S, Mathur RP, Sharma KH, Jaiswal AD. Observational study to evaluate the safety and efficacy of Saroglitazar in Indian diabetic dyslipidemia patients. Indian Heart Journal. 2015; 67(1): 23-26. 4. Sosale A, Saboo B, Sosale B. Saroglitazar for the treatment of hypertriglyceridemia in patients with type 2 diabetes: current evidence. Journal of Diabetes, Metabolic Syndrome and Obesity. 2015; 8: 189-196. 5. Agrawal R. The first approved agent in the Glitazar s class: Saroglitazar. Current Drug Targets. 2014; 15(2): 151-155. 6. Akanksha A. Saroglitazar: India s answer to diabetic dyslipidemia. International Journal of Pharmacology and Clinical Sciences. 2014; 3(1): 7-14. 7. Rajendra HJ, Kevinkumar K, Mukul RJ, Harilal P. Pharmacokinetics, safety and tolerability of Saroglitazar (ZYH1), a predominantly PPARα agonist Indian Journal of Pharmacy and Pharmacology, July - September 2015;2(3);150-154 154