JRI Thompson Hemiarthroplasty

Similar documents
Furlong H-A.C. THR System

TriboFit Hip System. Issue 3 - August 2013 English

Ceramic Femoral Heads and Acetabular Cup Liners

TC-PLUS Primary Knee IMPORTANT MEDICAL INFORMATION SPECIAL NOTE. This Package Insert is for product distributed in the US only.

DISTAL RADIUS. Instructions for Use

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

Instructions for use for Adler Cemented Total Hip Replacement Prosthesis

Instructions for use Prodisc -C Vivo Cervical disc prosthesis

Instructions for use for ADLER Cemented Bipolar hemi-arthroplasty Prosthesis

- October 2013 English

Important Notice to Users in the United States: General Safety Instructions

POLARCUP Dual Mobility System. General Safety Instructions. Instructions for Use. Duty to inform the patient. Implant passport

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

Revision A Date:

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

PRO-DENSE BONE GRAFT SUBSTITUTE

Important Notice to Users in the United States: General Safety Instructions

METAL HEMI SYSTEM

Progeny Hip Stem. Surgical Protocol and Product Specifications

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Duraloc CONSTRAINED LINER

EVOLVE TRIAD BONE SCREWS

Optimizing function Maximizing survivorship Accelerating recovery

Important notice: the device(s) can be prescribed and implanted only by a doctor legally authorized to perform this type of surgery.

For use by an Accredited Orthopaedic Surgeon only

Yasargil Permanent Aneurysm Clips

Salto Talaris Total Ankle Prosthesis

Doc. No.: IU/8 for. Rev. No.: 07 ResTOR Prosthesis

WristMotion Wrist Hemiarthroplasty System Instructions for Use

Hip Resurfacing System

EasyStep. Operative technique

BIOFOAM ANKLE SPACER BLOCK

The following languages are included in this packet:

Optimum implant geometry

ENDO-FUSE INTRA-OSSEOUS FUSION SYSTEM The following languages are included in this packet:

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

SL-PLUS MIA Stem, SL-PLUS MIA Stem Lateral, SL-PLUS/ INTEGRATION-PLUS MIA Stem with Ti/HA, SL-PLUS/INTEGRATION-PLUS MIA Stem Lateral with Ti/HA

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

Lapidus Arthrodesis System Instructions for Use

For use by an Accredited Orthopaedic Surgeon only

SIDEKICK EZ FRAME EXTERNAL FIXATION SYSTEM The following languages are included in this packet:

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

BIOLOX delta Option Ceramic Femoral Head System. Product Features and Instructions for Use

Scan Bi-Polar 22/28. Operative Technique

Technique Guide Small Bone Fusion System

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

SURGICAL TECHNIQUE. Pivot Bipolar Solitude Unipolar

Talar Dome System Surgical Technique

Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius.

Technique Guide Wrist Hemiarthroplasty System

BIOLOX delta Option Ceramic Femoral Head System

Bi-Polar 22.2mm & 28mm System - Operative technique

CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Greater Component Accuracy...

EVOLVE TRIAD SYSTEM

The following languages are included in this packet:

The short stem hip system Surgical Technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

REPIPHYSIS LIMB SALVAGE SYSTEM

FastFrame External Fixation System. Damage Control Surgical Technique

Positioning Sleeve Surgical Technique

INTELLIGENT SPINAL SYSTEM

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

operative technique Kent Hip

Bone Bangalore

KASM Knee Articulating Spacer Mold. Surgical Summary

DARCO MIS FOREFOOT SCREW

Description Materials Indications Patient selection factors to be considered include: Contraindications Absolute contraindications include:

AVANTEON. Operative Technique & Catalogue Information AVANTEON

Surgical procedure. METS Coned Hemi-Pelvis

Headless Compession Screw 2.5 / 3.0

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

Metha Short Hip Stem System

Ovation Hip System. Surgical Technique

D. The following factors are of extreme importance to the eventual success of the procedure.

Use Of A Long Femoral Stem In The Treatment Of Proximal Femoral Fractures: A Report Of Four Cases

Technique Guide Hip Resurfacing System

SURGICAL TECHNIQUE GUIDE

INTRAMEDULLARY NAILING TIBIA AND FEMUR 1.3 TIBIAL AND FEMORAL NAILING FEMORAL NAILING WITH RETROGRADE INSERTION IMPLANTS AND OPERATING MANUAL

Tradition Hip Primary Surgical Technique

Technique Guide KISSloc Suture System

Medium External Fixator Pediatric Femoral Shaft Frame. Using medium multi-pin clamps.

HELIOS h i p s y s t e m

EXTERNAL FIXATION SYSTEMS The following languages are included in this packet:

Flexible Fragment Fixation. Surgical Technique

Telya. Varisation staple. Surgical Technique. Irish Distributer: O'Mara Medical Tel

Surgical technique. Dynamic Simulation Personalised Solution

TaperFill. Surgical Technique

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

North of England Bone and Soft Tissue Tumour Service

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

C-THRU Anterior Spinal System

Metallic Internal Fixation Devices The following languages are included in this packet:

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

Transcription:

JRI ORTHOPAEDICS LTD 18 Churchill Way, 35A Business Park, Chapeltown, Sheffield, S35 2PY, UK Instructions for Use JRI Thompson Hemiarthroplasty Page 1 of 6

English 3 Page 2 of 6

Important Information Please read instructions for use and corresponding operative technique, prior to use in a clinical setting. The Surgeon should be familiar with the appropriate operative technique. Material(s) Material(s): Standard(s): CoCr BS ISO 5832-4 Intended Use The JRI Thompson Hemiarthroplasty Stem is a collared Cobalt Chrome femoral prosthesis, intended for use with cement in hip hemi-arthroplasty for the management of hip fractures. Description JRI Thompson Hemiarthroplasty Stems are a single use, Cobalt chrome, sterile implant intended for use with cement during hemi-hip arthroplasty. The primary design function is the restoration of biomechanics via replacement of the damaged femur and femoral head. JRI Thompson Hemiarthroplasty Stems are supplied sterile via gamma irradiation, in a single pack, double-barrier packaging. Extensive clinical use of the Thompson stem design has proven the biomechanical stability of the device. Various sizes of the implant are available to accommodate anatomical variations of the acetabulum. Indications JRI Thompson Hemiarthroplasty Stem are indicated for the treatment of fractures of the femoral neck. Contra-indications The device should NOT be implanted where there is active infection, insufficient bonestock to support the prosthesis or provide adequate fixation. JRI Thompson Hemiarthroplasty is not intended for use in revision surgery. Further contra-indications may be, but are not limited to the following conditions: Severe muscle, nerve or vascular diseases that endanger the extremity in question Severe deformations, tumours Severe osteoporosis or deficient bone substance that may endanger stable seating of the prosthesis Systematic and metabolic disorders Weakened or compromised immune system (HIV, tumours, infections) Precautions The following conditions require caution and due consideration during pre-operative planning by the surgeon: Page 3 of 6

Obese or severely overweight patients Excessive loading through arduous activity Lack of mental faculties to understand post-operative recuperative regime Alcohol dependency or drug abuse History of falls or disabilities. In patients with a high body mass index, where delayed surgery is feasible, it is advisable that a programme of weight reduction is undertaken prior to any joint replacement surgery. Warning This device should only be implanted by operating surgeons who are familiar with the general problems of prosthetic surgery and who are sufficiently trained to the product-specific operative technique. The surgeon is responsible for ensuring the surgery is carried out properly and in line with the instructions provided in the operative technique. As a manufacturer, JRI Orthopaedics Ltd. Is not responsible for any complications arising from incorrect diagnosis, incorrect choice of implant, incorrect operative technique, treatment methods limitations or inadequate asepsis. Pre-operative Pre-operative planning allows the surgeon to assess for implant size and restoration of biomechanics. Failure to carry out proper planning may lead to incorrect choice of implant type/size. Ensure all implant sizes and required instrumentation are available prior to surgery. Consult operative technique and training materials provided by JRI Orthopaedics Ltd. before use. Functionality of surgical instruments should be checked. Use of damaged instruments may lead to early failure of implant. Transient bacteraemia can occur after surgical procedures. To prevent late infection at the implant site, many orthopaedic surgeons advise the use of antibiotic prophylaxis before and after such procedures for their patients. Intra-operative This implant is intended for use with cement. The surgeon must follow the cement manufacturer instructions concerning preparation and technique. Avoid contact with materials that might damage the surface of the implant after removing from packaging. It is important to check the implant before it is inserted to ensure there is no damage. Packaging should only be removed immediately prior to implantation. Prior to wound closure, the surgical site should be cleared from bone cement, particulate matter or other debris. Implants MUST NOT be re-used under any circumstances as the functionality, integrity and/or sterility of that device may have been adversely affected and therefore cannot be guaranteed. Post-Operative Physicians should ensure patients are aware of implant loading limitations and ensure consistent postoperative care, from a suitably qualified professional, is made available. Page 4 of 6

Post-operative care should incorporate recognised procedures and take into account information from the operative technique and documented according to internal hospital procedures. Failure to do this may result in malalignment, delayed wound/bone healing, implant failure, infection or impaired joint function. Side Effects As with all major surgical procedures, side effects and adverse events can occur. Some of the more common complications include: Problems resulting from anaesthesia and patient positioning (pain, nausea etc.) Infection Aseptic loosening of implant Dislocation, subluxation, insufficient range of movement, leg length discrepancy Damage to soft tissue Fracture of implant, bone or cement Allergy/hypersensitivity reactions Cardiovascular/pulmonary embolism, respiratory infection, venous thrombosis, neuronal dysfunction, haematoma or delayed wound healing Revision In the event the Thompson Hemiarthroplasty requires revising; ensure all fragments or the primary prosthesis are removed. Clean and prepare the area for implantation in line with current Instructions for Use and Operative Technique of selected revision implant, prior to insertion of device. Storage & Handling Store implants in their original protective packaging in a clean and dry atmosphere. Do not use if the packaging is damaged. Do not use this product after the expiry date (year-month) shown on the product packaging. Avoid removing from packaging until immediately prior to use. Inspect device prior to use. Visibly damaged, scratched, improperly handled implants and implants that have already been used must not be implanted under any circumstances as the functionality, integrity and/or sterility of that device may have been adversely affected and therefore cannot be guaranteed. MRI Safety Information Non-clinical testing has demonstrated that JRI Hip Systems are MR Conditional. A patient with this device can be safely scanned in an MR system meeting the following conditions: Static magnetic field of 3.0 T Maximum spatial field gradient of 720 gauss/cm Maximum whole body averaged specific absorption rate (SAR) of 3.0W/kg Under the scan conditions defined above, the JRI Thompson Hemi-Arthroplasty Stem is expected to produce a maximum temperature rise of 1.7ºC after 15 minutes of continuous scanning The image quality may be compromised if the area of interest is in the exact same area, or relatively close to, the position of the medical device. Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary: Pulse Sequence T1-SE T1-SE GRE GRE Signal Void Size 42,763-mm 2 17,875-mm 2 56,249-mm 2 28,917-mm 2 Page 5 of 6

Plane Orientation Parallel Perpendicular Parallel Perpendicular Additional information regarding MRI safety is available upon request at JRI Orthopaedics Ltd. Functional Device Lifespan The functional lifespan of an implant may be impacted by surgeon and selected operative technique, patient physiology and activity levels. Whilst it is normally expected that the lifetime of this implant will exceed a minimum of 10 years, it will be subject to wear and tear through normal everyday use. Products intended for single-use must not be re-used. Re-use or reprocessing (e.g. cleaning and re-sterilisation) may compromise the structural integrity of the device and / or lead to device failure which may result in patient injury or death. Reuse or reprocessing of single-use devices may create a risk of contamination (e.g. transmission of infectious material) which may result in injury or death. Further information For product specific operative technique training or further information, please contact your JRI Orthopaedics Ltd Sales Representative or JRI Orthopaedics Ltd directly. JRI ORTHOPAEDICS LTD 18 Churchill Way, 35A Business Park, Chapeltown, Sheffield, S35 2PY, UK Tel: +44(0)114 345 0000 Fax: +44(0)114 345 0004 www.jri-ltd.co.uk Page 6 of 6