Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow

Similar documents
Intro to Glaucoma/2006

Glaucoma: Diagnostic Modalities

Clinical Ophthalmology

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India

INTRODUCTION S. HERDENER, D. HAFIZOVIC, M. PACHE, S. LAUTEBACH, J. FUNK. University Eye Hospital, Freiburg - Germany

Central corneal thickness determined with optical coherence tomography in various types of glaucoma

Clinical and OCT features of different types and stages of diabetic optic neuropathy

Written by Administrator Wednesday, 13 January :27 - Last Updated Thursday, 21 January :34

Dina H. Erickson, O.D., a Denise Goodwin, O.D., a Michael Rollins, O.D., b Amber Belaustegui, O.D., c and Chad Anderson a

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

CLINICAL SCIENCES. Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry

1/31/2018. Course Objectives. Diagnostic Testing. Optic Nerve Damage ANATOMY AND PHYSIOLOGY OF A GLAUCOMA WORK-UP/TONOMETRY TECHNICIAN: -SDP

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

Central corneal thickness among glaucoma patients attending Menelik II Hospital, Addis Ababa, Ethiopia

True IOP No Doubt Facts and Figures Figures. Ziemer Ophthalmic Systems AG a Ziemer Group Company Allmendstrasse 11 CH-2562 Port, Switzerland

International Journal of Health Sciences and Research ISSN:

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer

Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

LARGE DISCS WITH LARGE CUPS A DIAGNOSTIC CHALLENGE IN AFRICAN PATIENTS. Darshana Soma

Color weakness in congenital color perception deficiency of various degrees

Correlating central corneal thickness and intraocular pressure in ocular hypertension and glaucoma

An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement

Correlation between presence of primary irisand cilliary body cysts and intraocular pressure

Correspondence should be addressed to Fusako Fujimura;

STUDY OF EFFECTIVENESS OF LENS EXTRACTION AND PCIOL IMPLANTATION IN PRIMARY ANGLE CLOSURE GLAUCOMA Sudhakar Rao P 1, K. Revathy 2, T.

Behandlungsstrategien beim Offenwinkelglaukom. F. Bochmann, Augenklinik LUKS

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors

The Role of the RNFL in the Diagnosis of Glaucoma

Glaucoma Clinical Update. Barry Emara MD FRCS(C) Giovanni Caboto Club October 3, 2012

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

CLINICAL SCIENCES. Clinical Significance of Central Corneal Thickness in the Management of Glaucoma

Predicting the risk for progression of acquired myopia in school-age children

CLINICAL SCIENCES. Differences in Visual Function and Optic Nerve Structure Between Healthy Eyes of Blacks and Whites

Central corneal thickness and vascular risk factors in normal tension glaucoma

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Goals. Glaucoma PARA PEARL TO DO. Vision Loss with Glaucoma

Role of central corneal thickness measurement in management of open angle glaucoma and glaucoma suspects in Calabar, Nigeria

1/25/2019 OCT & OCTA RETINAL IMAGING: HOW TO PREVENT RAGING GLAUCOMA! THE ORIGINAL RAGING GLAUCOMA OCT RETINAL IMAGING OPTIC NERVE HEAD EXAMINATION

Clinical Guidance and Monitoring for Change. Cecilia Fenerty MD FRCOphth Manchester Royal Eye Hospital

Glaucoma. Glaucoma. Optic Disc Cupping

NON-INVASIVE OCULAR RIGIDITY MEASUREMENT: A DIFFERENTIAL TONOMETRY APPROACH

GLAUCOMA SUMMARY BENCHMARKS FOR PREFERRED PRACTICE PATTERN GUIDELINES

THE CHRONIC GLAUCOMAS

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

9/25/2017 CASE. 67 years old On 2 topical meds since 3 years. Rx: +3.0 RE LE

Optic nerve head morphometry in healthy adults using confocal laser scanning tomography

Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1

Investigation of the relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertension

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.

Policy #: 354 Latest Review Date: July 2011

Structural changes of the anterior chamber following cataract surgery during infancy

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Collaboration in the care of glaucoma patients and glaucoma suspects. Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012

Based on the studies by Goldmann and Schmidt 1 and Ehlers. Central Corneal Thickness Correlated with Glaucoma Damage and Rate of Progression

THE CHRONIC GLAUCOMAS

3/23/2016. Regina Smolyak, MD Glaucoma Service Flaum Eye Institute

Management of Angle Closure Glaucoma Hospital Authority Convention 18 May 2015

Interpretation of corneal tomography

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

PRACTICAL APPROACH TO MEDICAL MANAGEMENT OF GLAUCOMA

Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry

Medical Management of Glaucoma

Glaucoma Intraocular Pressure What Will I Notice?

Clinical Profile of Primary Open Angle Glaucoma Suspects.

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

EXPERIMENTAL AND THERAPEUTIC MEDICINE 6: , 2013

The Ocular Response Analyzer (ORA; Reichert Ophthalmic

SOCT Copernicus REVO. * - Currently import and overlay are avaibale in manual mode only

Retinal Nerve Fiber Analysis: the Role It Plays in Assessing Glaucoma Grace Martin, CPOT

Modelling form deprivation myopia in experiment

Closed Angle Glaucoma Or Narrow Angle Glaucoma. What s is a closed angle type of glaucoma,

Clinical decision making based on data from GDx: One year observations

Central Corneal Thickness and its Association with Ocular Parameters

The Association of Central corneal thickness with Intra-ocular Pressure and Refractive Error in a Nigerian Population

4/06/2013. Medication Observation POAG. Proportion. Native American 0.1% 0.4%

Ganglion Cell-Inner Plexiform Layer Assesment with Cirrus Hd 5000 in Early Glaucoma

Is this glaucoma? Leo Semes, OD Michael Chaglasian, OD Danica Marrelli, OD. Optometry s Meeting 2015 Seattle, WA

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation

PREVALENCE OF GLAUCOMA AMONG FISHERMEN COMMUNITY OF MUNDRA TALUKA OF KUTCH DISTRICT- A CROSS- SECTIONAL STUDY

The innovative aspects are that ORA G3 is currently the only device capable of measuring corneal hysteresis.

A Case of Primary Congenital Glaucoma

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Glaucoma is the leading cause of irreversible blindness in

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

Summary HTA HTA-Report Summary Validity and cost-effectiveness of methods for screening of primary open angle glau- coma

Relationship between central corneal thickness and parameters of optic nerve head topography in healthy subjects

CLINICAL SCIENCES. Validation of a Predictive Model to Estimate the Risk of Conversion From Ocular Hypertension to Glaucoma

THE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS

53 year old woman attends your practice for routine exam. She has no past medical history or family history of note.

pat hways Medtech innovation briefing Published: 19 November 2014 nice.org.uk/guidance/mib14

Is NTG different from POAG?

Corporate Medical Policy

CLINICAL SCIENCES. Comparison of Ocular Response Analyzer Parameters in Chinese Subjects With Primary Angle-Closure and Primary Open-Angle Glaucoma

Deep anterior lamellar keratoplasty (DALK) is considered

Transcription:

Changes in corneoscleral rigidity and corneal thickness at various target intraocular pressures in patients with stabilized primary open-angle glaucoma Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow SI Filatov Institute of Eye Diseases and Tissue Therapy of NAMS of Ukraine ; Odessa (Ukraine) E-mail: tatarina.j.a@gmail.com Keywords: target intraocular pressure, primary open-angle glaucoma, corneal thickness, corneal rigidity Introduction. Current methods for determining target IOP have disadvantages. Investigation of data on corneoscleral rigidity and corneal thickness in patients with stabilized primary open-angle glaucoma of stages I-II may improve the method of determining target IOP. Purpose. To study the relationship between indices of corneoscleral rigidity, corneal thickness and target IOP in patients with stabilized primary open-angle glaucoma (POAG) of stages I-II. Material and Methods. 30 patients (30 eyes) with stabilized POAG of the І-ІІ stage were examined. The patients underwent pachymetry, applanation tonometry, dynamic contour tonometry, corneal rigidity determination and tonography. The progression of glaucoma was monitored by the HFA II Central 30-2 Threshold Test and SOCT Copernicus + units. Target IOP was calculated taking into account the age and the level of diastolic blood pressure. Results. It was found that, in group 1 with target IOP of 6.2-13.9 mm Hg, the corneal thickness was 540-590 μm and rigidity of the cornea ranged from 1.0 to 4.0 mm Hg; while in group 2 with target IOP of 14.0-16.8 mm Hg, the corneal thickness was 510-570 μm and rigidity of the cornea ranged from -3.0 to 1.5 mm Hg. Conclusions. It was found that the lower a value of achieved target IOP, the higher corneal rigidity in patients with stabilized stage I-II POAG. Introduction A key point for effective treatment of patients with primary open-angle glaucoma (POAG) is reducing intraocular pressure (IOP) to target IOP. Target IOP is an upper limit of IOP at which it is possible to control damage to inner eyeball structures and breakdown of visual function [1]. The existing methods for determining target IOP suffer from a number of shortcomings since it is determined empirically considering all risk factors of a patient: baseline IOP, a glaucoma stage, a progression rate during follow-up, age, and diastolic blood pressure [2]. This keeps out of accurate determining a target IOP level. Since there is no generally recognized method to determine tolerant and target IOP, observational studies on stabilization of glaucomatous process in optimal POAG treatment are running. In the literature, there are single data on a role of corneoscleral rigidity in the development of glaucoma [3]. To-date, corneascleral rigidity is considered as corneal stiffness that characterizes an ability of fibrous tunica of the eye to resist changing the shape under external and internal macroactions [4]. It has been found that rigidity of the fibrous tunica of the eye is pathologically increased even at the early stage of glaucoma; herewith, rigidity progresses gradually, reflecting the stages of glaucoma, with a sudden change only in going from the advanced to end stage of glaucoma [5]. It should be noted that a clinical value of such a parameter as corneascleral rigidity has not been determined completely in glaucoma diagnostics and it is important to detail its common sense and prognostic value for patients with POAG. Unlike cornealscleral rigidity, the corneal thickness is a more investigated parameter which has an effect on IOP and glaucoma diagnostics in general. Previously, corrective mechanisms have been developed for calculating an IOP level in dependence on the central corneal thickness (CCT). Analyzing CCT values and corresponding IOPs has shown that with a decrease in the central corneal thickness there is a decrease in intraocular pressure according to applanation tonometry readings [6]. Later on, J.H. Liu has demonstrated that tonometry errors mostly depend on the corneal biomechanics rather than on the corneal thickness [7]. P eretyagin O.A., D mitriev S.K., Lazar Yu.M., Tatarina Yu.A., 2018 27

We suppose that studying values of corneal rigidity and thickness in patients with stabilized primary open-angle glaucoma of stages I-II can contribute to improving the method for determining target IOP. Purpose. To study the relationship between values of corneascleral rigidity, corneal thickness, and target IOP in patients with stabilized primary open-angle glaucoma of stages I-II. Material and Methods 20 patients (30 eyes) with stabilized primary openangle glaucoma of stages I-II were examined. All patients were performed a comprehensive ophthalmic examination including visual acuity testing using the Sivtsev-Golovin tables, autokeratorefractometry, perimetry, biomicroscopy, ophthalmoscopy, pachymetry, applanation tonometry by Maklakov, dynamic contour tonometry, corneal rigidity testing, computed corneal topography, optical A-scanning, tonography A vision field analyzer (HFA II Central 30-2 Threshold Test) and SOCT Copernicus were used to monitor changes in glaucomatous and morphological parameters. Maklakov tonometry and dynamic contour tonometry were performed. Maklakov applanation tonometry was made by a 5g tonometer. True IOP was determined by computed tonography. Dynamic contour tonometry was performed using a PASCAL tonometer which operates on a dynamic contour based on a physical phenomenon of the Pascal law. A tonometer head, contacting with the cornea, is of a concave shape with a contour duplicating a curve of the anterior corneal surface and enables to minimize the impact of corneal properties on readings. The piezoresistive pressure sensor is integrated into the contour. The contour has a 10.4 mm radius or 32.5D according to keratometry, which makes it possible to use for the cornea a device with a curve radius over 5-6 mm (55-65D) and central thickness of 300-700 µm. In such conditions, the curvatures of the cornea and the contour match in a certain area with minimal pressure on the eyeball (less than 1 g) and the sensor registers IOP by a direct transcorneal method [8]. Rigidity of the corneoscleral coat of the eye was determined as a difference between IOP measured by Maklakov tonometry and true IOP measured by PASCAL tonometry [9]. Target IOP was calculated in consideration with age and diastolic blood pressure (DBP) using a formula: Р0 target = 9.5 + 0.07 DBP 0.024 age [2]. Statistical data were processed by methods recommended for medical research [10, 11]. All data obtained were based into a specially designed form, in which they were analyzed and simultaneously coded into digital values as a numerical, ordinal, and nominal scale. Database creation, statistical and graphical analyses were made on a personal computer using licensed software, including application software packages STATISTICA 7.0 and Microsoft Excel. When analyzing the statistical data, we determined sample-based parameters which are given in tables and have meanings as follow: М mean; m error of mean; n a number of patients in the studied group; SD standard deviation of mean, р a level of significance. The differences were accepted significant with a zero hypothesis probability less than 5% (р <0.05). Results and Discussion Target IOP, recommended due to age and DBP, was achieved in all 30 patients (30 eyes) with stabilized POAG of stages II-III and was within the range between 6.2 and 16.8 mm Hg (Table 1). True IOP was assessed using tonography. Stabilization of glaucomatous process was controlled considering the parameters of mean deviation (MD), pattern standard deviation (PSD) on computed perimetry; parameters of optic disc cupping, a cup-to-disc ratio, cupping area, a vertical cup-to-disc ratio; and OCT data on the mean thickness of retinal nerve fibers in all quadrants in dynamics. Glaucomatous process stabilization control showed that the patients in the studied group had a stabilized form of stage I-II glaucoma. Based on a level of target IOP, we divided the patients into two groups: group 1 comprised 11 patients with target IOP ranging from 6.2 to 13.9 mm Hg; group 2 comprised 19 patients with target IOP ranging from 14.0 to 16.8 mm Hg (Fig. 1). The central corneal thickness was measured in all patients and its range was from 510 to 590 μm (Table 2). We analyzed, evaluated, and compared the OCT data of the studied groups with different target IOPs (Fig. 2). Thus, the corneal thickness in group 1 (target IOP = 6.2-13.9 mm Hg) was equal to 540 to 590 μm (Fig. 3) while in group 2 (target IOP = 14.0-16.8 mm Hg) that ranged from 510 to 570 μm (Fig. 4). Afterwards, corneoscleral rigidity was calculated in the patients of each group (Table 3). It was found that rigidity of the cornea ranged from 1.0 to 4.0 mm Hg and from -3.0 to 1.5 mm Hg in group 1(with a target IOP of 6.2-13.9 mm Hg and corneal thickness of 540-590) and 2 (with a target IOP of 14.0-16.8 mm Hg and corneal thickness of 510-570), respectively (Fig. 5). Figure 5 demonstrates that the lower a value of achieved target IOP, the higher corneal rigidity in the patients with stabilized stage I-II POAG. Conclusions First, our findings point at the fact that a value of target IOP must be lower in patients with higher rigidity than in patients with low rigidity. Second, when calculating and controlling a level of target IOP in POAG patients, values of the corneal thickness and corneoscleral rigidity should be considered. 28

References 1. Vodovozov AM. [Tolerant and intolerant intraocular pressure in glaucoma]. Volgograd; 1991. 160p. In Russian. 2. Fokin VP, Balanin SV. [Determination of target intraocular pressure in patients with primary open-angle glaucoma] Glaukoma. 2007;6(4):16-9. In Russian. 3. Boriskina LN, Balanin SV, Makovkin EM. [Corneoscleral rigidity as a cumulative biometric parameter]. Vestnik OGU. 4(153):48-50. In Russian. 4. Svetlova OV, Koshits IN. [Physiological functions of fibrous tunic of eye and their operative mechanisms. Normal and pathological physiology of eye. Textbook]. SPb: Izdatelstvo GBOU VPO SZGMU im. I.I. Mechnikova; 2013. 71p. In Russian. 5. Svetlova OV. [Functional characteristics of interaction of the sclera, accommodation and drainage systems of the eye in glaucomatous and myopic pathology]. Author s thesis for Dr. Med. Sc. Moscow; 2010:24-7. In Russian. 6. Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophtalmol. (Copenh). 1975;53:34-43. 7. Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J. Cataract. Refract. Surg. 2006;32(7):1073-6. 8. Kaufmann C, Bachmann LM, Thiel MA. Comparison of dynamic contour tonometry with Goldmann applanation tonometry. Invest Ophthalmol Vis Sci. 2004;45:318-21. 9. Gontijo L. Corneal rigidity in numbers http://escrs. conference2web.com/content/4496// 27th Congress of the ESCRS : Barcelona, 2009. 10. Glantz S. [Medical and biological statistics. Translated from English by Danilov YuA]. M.:Praktika;1999.459p. In Russian. 11. Lapach SN, Chubenko AV, Babich PN. [Statistical methods in medical and biological investigations using Excel]. K.:Morion LTD; 2000. 320p. In Russian. Table 1. Statistical values of patients with true target intraocular pressure (IOP) True target IOP, mm HG. 30 14.8 6.2 16.8 2.98 Table 2. Statistical values of patients with different values of central corneal thickness (CCT), μm ССТ, μm 30 548.2 510 590 21.7 Table 3. Statistical values of patients with different values of corneoscleral rigidity (Ec), mm Hg Ес, mm Hg 30 0.9-3.0 4.0 1.9 29

6.2-13.9 mm Hg 14.0-16.8 mm Hg Fig. 1. A percentage ratio of stabilized primary open-angle glaucoma patients based on target intraocular pressure (mm Hg) Fig. 2. A ratio of true target intraocular pressure and central corneal thickness in patients with stabilized stage I-II primary open-angle glaucoma Fig. 3. Distribution of true target intraocular pressure (P0), mm Hg, and central corneal thickness, μm, in group 1 of patients with stabilized primary open-angle glaucoma of stages I-II 30

Fig. 4. Distribution of true target intraocular pressure (P0), mm Hg, and central corneal thickness, μm, in group 2 of patients with stabilized primary open-angle glaucoma of stages I-II Fig. 5. Distribution of true target intraocular pressure, mm Hg, due to age and diastolic blood pressure in groups with different central corneal thicknesses, μm, and corneal rigidity (Ec, mm Hg.) 31