Original article: A Comparative evaluation of three different Ni-Ti rotary files using Crown Down technique. An Exvivo study using C T scan.

Similar documents
Evaluation of canal preparation with rotary and hand Niti files in curved root canals using Cone Beam Computed Tomography: An In Vitro Study

in simulated curved canals

Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals

A comparison of root canal preparations using stainless steel, Ni-Ti hand, and Ni-Ti engine-driven endodontic instruments an in vitro study

Comparison of canal preparation pattern of K3 and ProTaper rotary files in curved resin blocks

Endodontic Shaping Performance Using Nickel Titanium Hand and Motor ProTaper Systems by Novice Dental Students

JCDP ORIGINAL RESEARCH ABSTRACT INTRODUCTION

Comparison of Remaining Root Dentine Thickness After Three Rotary Instrumentation Techniques By Cone Beam Computerised Tomography-An Invitro study

Last Generation Endodontic Instruments. A Study of their. Drs. Siragusa and Racciatti are affiliated with the Department of

Shaping Potential of Manual NiTi K-File and Rotary ProTaper and Analyzing the Final Outcome of Shaped Canals using CT

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

Shaping ability of progressive versus constant taper instruments in curved root canals of extracted teeth

Comparison of Canal Preparation Pattern of K3 and ProTaper Rotary Files in Curved Resin Blocks

CBCT Evaluation Of Glidepath Preparation By Different Rotary Nickel Titanium Glide Path...

CBCT EVALUATION OF CANAL TRANSPORTATION USINGNEWER ROTARY NI-TI FILE SYSTEMS-AN IN VITRO STUDY.

Comparison of the Remaining Dentin Thickness in the Root after Hand and Four Rotary Instrumentation Techniques: An in vitro Study

In vitro evaluation of root canal preparation with plastic endodontic rotary finishing file - A SEM study

ORIGINAL ARTICLE INTRODUCTION

Creating a glide path for rotary NiTi instruments: part two

Influence of cervical preflaring on apical file size determination - An in vitro study

Comparison of the shaping ability of Twisted Files with ProTaper and RevoS nickel-titanium instruments in simulated canals

ENDODONTOLOGY ABSTRACT INTRODUCTION

Tools for Endodontic Success

Shah. Management of a maxillary second premolar with an S-shaped root canal - An endodontic. Management of a maxillary second premolar

Safety and Simplicity!

A comparative scanning electron microscopic study of the effect of three different rotary instruments on smear layer formation

Instructions for use: FlexMaster. the rotary NiTi-System for every case. Endo Easy Efficient

Case Report Root Canal Treatment of Mandibular Second Premolar with Three Separate Roots and Canals Using Spiral Computed Tomographic

In vitro Study of Apically Extruded Debris and Irrigant Following the Use of Conventional and Rotary Instrumentation Techniques

Research Article Assessment of Root Canal Enlargement Using Mtwo and BioRace Rotary Files

Working length changes following straight-line access and different coronal flaring methods

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography

Original Study. Annals of Dental Specialty Vol. 6; Issue 1. Jan Mar

EndoWave. Enhanced safety for root canal preparation. Thinking ahead. Focused on life.

Instruments used in Endodontics

Endodontics. Patented partial heat treatment Improved safety

WHERE SAFETY MEETS EFFICIENCY

Comparison of apical and coronal sealing in canals having tapered cones prepared with a rotary NiTi system and stainless steel instruments

Case Report Endodontic Management of Maxillary Second Molar with Two Palatal Roots: A Report of Two Cases

COMPARATIVE STUDY OF APICALLY EXTRUDED DEBRIS AND IRRIGANT AFTER USING TWO ROTARY SYSTEMS (K3, RACE)

Management of a Type III Dens Invaginatus using a Combination Surgical and Non-surgical Endodontic Therapy: A Case Report

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL

Case Report Endodontic Treatment of Bilateral Maxillary First Premolars with Three Roots Using CBCT: A Case Report

Failure of ProFile instruments used with air, high torque control, and low torque control motors

K3 Nickel-Titanium Files

Staining Potential of Calcium Hydroxide and Monochlorophenol Following Removal of AH26 Root Canal Sealer

Improve Your Root Canal Preparations with Adaptive Motion Technology

Comparison of Canal Transportation and Centering Ability of Rotary I-Race and BT-Race Systems using Cone Beam Computed Tomography: An in vitro Study

IN VITRO EVALUATION OF ROOT CANAL PREPARATION WITH TWO ROTARY INSTRUMENT SYSTEMS PRO TAPER AND HERO SHAPER

Before we begin demonstrating the shock of paradigms on the instrumentation

ENDO-EZE TM GENIUS ENDODONTIC SYSTEM WHERE SAFETY MEETS EFFICIENCY

ORIGINAL PAPERS. Porównanie skuteczności opracowania sztucznych kanałów w kształcie litery L dwoma systemami maszynowymi: Hyflex CM i ProTaper Next

IN VITRO EVALUATION OF DENTINAL

Case Report Endodontic Management of a Maxillary First Molar with Two Palatal Canals and a Single Buccal Canal: A Case Report

Research Article Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System

Effects of Simulated Lateral Canals on the Accuracy of Measurements by an Electronic Apex Locator

Comparison of NiTi-Tee and ProTaper rotary systems on. root canals using micro-computer tomography

Torque During Canal Instrumentation Using Rotary Nickel-Titanium Files

The Graduate School Yonsei University Department of Dentistry Myoungah Seo

MDJ The effects of canal preparation by different NiTi rotary Vol.:9 No.:2 2012

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file

An In Vivo Evaluation of Two Types of Files used to Accurately Determine the Diameter of the Apical Constriction of a Root Canal: An In Vivo Study

Morphological Analysis of Apical Foramen Over-instrumented by Three Rotary NiTi Systems

Endo Easy Efficient. The efficient NiTi system. User Information.

You succeed your root canal treatments! Characteristics...page 4. Instruments...page 6. Protocol...page 10. Questions & Answers...

LegacyENDO. Create your own Legacy! Controlled Memory Cross Cut. Apex Access. Multi Taper. K-Files

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone

A WHOLE NEW DIMENSION OF TOTAL PERFORMANCE.

Case Report. July 2015; Vol. 12, No. 7. Vineet Agrawal 1, Sonali Kapoor 2, Mukesh Patel 3

An in vitro comparison of different techniques for glide path preparation

Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography

A COMPARATIVE STUDY OF ROOT CANAL FILLINGS BASED ON WARM GUTTA-PERCHA CONDENSATION TECHNIQUES

Rotary Systems: An Insight

MAXILLARY FIRST MOLAR : AN ENIGMA FOR ENDODONTISTS

and shaping. Shaping is easily accomplished in straight canals; however, as the canal

Comparison of Spreader Penetration during Lateral Compaction of 0.04 and 0.02 Tapered Gutta-Percha Master Cones

e74 Department of Conservative Dentistry and Endodontics, Meenakshi Ammal Dental College a Reader.

Shaping ability of ProTaper Universal, WaveOne and ProTaper Next in simulated L-shaped and S-shaped root canals

Comparative Analysis of Efficacy and Cleaning Ability of Hand and Rotary Devices for Gutta-Percha Removal in Root Canal Retreatment: An in vitro Study

Case Report Management of Complex Root Canal Curvature of Bilateral Radix Entomolaris: Three-Dimensional Analysis with Cone Beam Computed Tomography

Obturation of internally prepared cavities (simulating internal resorption) with three different techniques

To Study the Crack Initiation on the Apical Root Surface Following Different Root Canal Preparation Techniques and Instruments: An In Vitro Study

Endodontic treatment of a maxillary first molar having three mesiobuccal canals with the aid of spiral computed tomography: a case report

Fauzia Ashraf, Pushpa Shankarappa, Abhinav Misra, Asheesh Sawhney, Nandamuri Sridevi, and Anu Singh

Relative efficacy of three Ni-Ti file systems used by undergraduates

A micro-computed tomographic evaluation of apical root canal preparation using three instrumentation techniques

QUINTESSENCE INTERNATIONAL ENDODONTICS

Computed tomography evaluation of rotary systems on the root canal transportation and centering ability

A survey on NiTi rotary instruments usage by endodontists and general dentist in Tehran

Integra Miltex. Endodontic Files. Limit uncertainty with the brand you trust

one file endo Endo Easy Efficient

A great file. Even better.

Endo Easy Efficient one file endo

Influence of operator experience on canal preparation time when using the rotary Ni-Ti ProFile system in simulated curved canals

Innovative revolutionary approach to root canal preparation

Race family Endodontic NiTi rotary files

Single File Reciprocating Technique Using Conventional Nickel Titanium Rotary Endodontic Files

flexible performance Chemin du Verger 3 CH-1338 Ballaigues Switzerland

Effective cleaning and shaping of the root

Comparison of the shaping ability of GT Series X, Twisted Files and AlphaKite rotary nickel-titanium systems in simulated canals

Transcription:

Bangladesh Journal of Medical Science Vol. 16 No. 02 April 17 Original article: A Comparative evaluation of three different Ni-Ti rotary files using Crown Down technique. An Exvivo study using C T scan. Abstract Bhatt A 1, Rajkumar B 2, Gupta V 3 Objective: This ex-vivo study evaluated and compared the canal transportation of the prepared root canals and centering ratio maintained by, and Twited Ni-Ti rotary files using Crown-Down technique. Materials and Method: Thirty non-carious extracted permanent human maxillary central incisors without any fracture and having Vertucci type I canal configuration were selected. The teeth were divided into 3 groups each group comprising of ten teeth. All the teeth were mounted on a wax block and pre instrumented canal CT Scan was performed. Access cavity preparation was done in group samples and canal was prepared using crown down technique by, and NiTi Rotary file systems for the respective groups. Image analysis was done at 9 levels to access transportation and centricity ratio from pre and post instrumented CT scan images. The results showed that Software program determined the volume of pre and post instrumented canals. Results: The Canal transportation occurred least in root canals prepared by files, followed by canals prepared by files and files. Centricity ratio was maintained the best in root canals prepared by twisted files. Conclusion: Within the parameters of this study, canals prepared by Files showed a well centered preparation and maintained the original shape of the root canal without any aberrations. Keyword: NiTi Rotary files; Canal shaping; Canal transportation; Centering ratio. Bangladesh Journal of Medical Science Vol. 16 No. 02 April 17. Page : 212-218 Introduction Biomechanical preparation, is recognized as being one of the most important stages in root canal treatment. 1,2 It thoroughly cleans and shapes the canals by removing the vital or necrotic tissues.this is carried out by enlarging and shaping the canal to allow for adequate chemical debridement, while preserving the radicular anatomy. 3 Regardless of the instrumentation technique, cleaning and shaping procedures invariably lead to dentine removal from the canal walls. 3 However, excessive dentine removal in a single direction within the canal rather than in all directions equidistantly from the main tooth axis causes canal transportation. 4 Historically, there have been two major techniques to clean and shape root canals: step-back and crowndown. 5,6 The step-back preparation results in a conservative apical preparation with coronal flaring but is also associated with certain limitations such as being time-consuming and procedural errors. 5 On the other-hand, crown-down technique initially shapes the coronal third while the apical preparation is carried out later. This is beneficial because it allows for early removal of coronal dentin, often the major restrictor to achieving and maintaining working length throughout any cleaning and shaping procedure. 6 1. Dr. Akanksha Bhatt, Assistant Professor, Department of Conservative Dentistry and Endodontics, BBDCODS, BBD University, Lucknow, India. 2. Dr. B. Rajkumar, Professor and HOD, Department of Conservative Dentistry and Endodontics, BBDCODS, BBD University, Lucknow, India. 3. Dr. Vishesh Gupta, Assosiate Professor, Department of Conservative Dentistry and Endodontics, BBDCODS, BBD University, Lucknow, India. Correspondence to: Dr. Akanksha Bhatt, Assistant Professor, Department of Conservative Dentistry and Endodontics,BBDCODS, BBD University, Lucknow, India-226028. E-mail: dr.a.bhatt@gmail.com 212

A Comparative evaluation of three different Ni-Ti rotary files using Crown Down technique. An Ex-vivo study... Methodology The present study was conducted in the Department of Conservative Dentistry and Endodontics, Babu Banarasi Das College of Dental Sciences, Lucknow, India and in collaboration with Raydent Imaging Centre, Lucknow. Thirty freshly extracted non carious permanent human maxillary central incisors were selected. The fractured teethor lacking vertucci type I canal configuration were excluded. Maxillary central incisors were extracted due to periodontal reasons. Due to high prevalence of vertucci type I canal morphology and its easy availability the maxillary central incisors were chosen. Randomly all the teeth were divided into 3 groups, each comprising of ten teeth samples. Teeth were stored in 10% formalin until further used.all the teeth were mounted on a block made of wax sheet and this was placed in Siemens CT Scanner. 7 It was aligned so that the long axis of the roots were perpendicular to the beam. The teeth were scanned using 1.0 mm thick slices. It provides 1.0.mm thick axial sections and reconstruction tools for maximum intensity projection and volume rendering (volume reconstruction by intensity 3 D). The preinstrumented CT scans were made with a Bone Tissue window (120Kv and 90mA), 1.0 mm thick axial sections with 1.0 mm increments, 0.9 pitches, 207 mm display field of view, and beam incidence at the central portion on the device used to fix the specimens. After obtaining pre-instrumentation CT scans of all teeth reconstructions of the 1.0 mm thick axial sections were performed, which provided better image definition. Ethical approval: This study was approved by ethical committee of Babu Banarasi Das College of Dental Sciences, Lucknow, India Canal instrumentation After the pre-instrumented scan, the teeth samples of all the three groups were individually removed from the block made of wax sheet. They were hand held and were prepared using Crown Down technique by (VDW, Munich, Germany), (Dentsply, Maillefer, Ballaigues, Switzerland) and files (SybronEndo, Orange, CA, USA). First the access cavities were prepared, and the canals were located and explored with an ISO size 10 K File, which were passively advanced into the canals until the tip of the instrument penetrated and adjusted to the apical foramen. The actual canal length was recorded, and the working length was calculated by subtracting 1 mm from this measurement. The canals were instrumented at a speed of 350 rpm using a 16: 1 reduction hand piece powered by Endo motor(x Smart, Dentsply, Switzerland). The final apical preparation was set to ISO no 25. Copious Irrigation was done with 3 % Sodium Hypochlorite after the use of each file. 15% EDTA Glyde (Dentsply, Switzerland) was used as a lubricant before and after use of each file. GROUP 1 ( Ni-Ti files) The instrumentation sequence according to the manufacturer s instructions was as follows: 1. 0.04 taper size 10 instrument was used to the full length of the canal. 2. 0.05 taper size 15 instrument was used to the full length of canal. 3. 0.06 taper size 20 instrument was used to the full length of canal. 4. 0.06 taper size 25 instrument was used to the full length of canal. GROUP 2 ( Ni-Ti files) The instrumentation sequence according to the manufacturer s instructions was as follows: SX File (tip size: 19; tapers: 3.5 19%) used to taper of the coronal part of the canal. Shaping File No. 1 (tip size: 17; tapers: 2 11%) used to the full length of canal. Shaping File No. 2 (tip size: 20; tapers: 4 11.5%) used to the full length of canal. Finishing File No. 1 (tip size: 20; tapers: 5.5 7%) used to the full length of canal. Finishing File No. 2 (tip size: 25; tapers: 5.5 8%) used to the full length of canal. GROUP 3 ( Ni-Ti files) The instrumentation sequence according to the manufacturer s instructions was as follows: File size 25 taper.08 used to shape the coronal one third or two thirds of the root canal. File size 25 taper.06 used to shape the canal until 2 mm short of working length. File size 25 taper.04 used to shape the canal till working length. File size 25 taper.06 used to shape the canal till working length. File size 25 taper.08 used to shape the canal till working length. The instrumented canals were scanned using CT as done for the pre-instrumented canal with the same parameters settings. Dicom software was used to 213

Bhatt A, Rajkumar B, Gupta V record the image. The final measurements were done through proprietary software of CT scan system.same computer settings and viewing parameters were used to view the preoperative and post-operative images. Cross sectional images of each tooth were produced at 9 levels from the apex with the help of CT scan software. Each cross-sectional image represented a 1.0mm thick slice through the teeth, perpendicular to the long axis at the particular level. For the evaluation of canal transportation in Buccolingual(BL) as well as Mesiodistal(MD) direction was observed by the following formula. 15 BL direction = (X 1 X 2 ) (Y 1 -Y 2 ) MD direction = (A 1 -A 2 ) - (B 1 -B 2 ) X 1 buccal surface of the Root to the periphery of pre X 2 buccal surface of the Root to the periphery of post Y 1 Lingual surface of the Root to the periphery of pre Y 2 Lingual surface of the Root to the periphery of post A 1 represented the shortest distance from the Mesial surface of the Root to the periphery of pre A 2 represented the shortest distance from the Mesial surface of the root to the periphery of post B 1 represented the shortest distance from the Distal surface of Root to the periphery of pre instrumented canal. B 2 represented the shortest distance from the Distal surface of the root to the periphery of post The result of zero from the canal transportation indicated no canal transportation. The mean centering ratio was calculated for each section by the formula: (X 1 -X 2 ) / (Y 1 -Y 2 ) or (Y 1 -Y 2 ) / (X 1 -X 2 ) If these numbers are not equal, the lower figure is considered as the numerator of the ratio. According to this formula, a result of 1 indicates perfect centering. Observation & Results Canal Transportation: Table1: Analysis of Mean Canal Transportation by different files (Apical Third Region) Mean SD Mean SD Mean SD S1 0.33 0.14 0.84 0.34 0.12 0.03 S2 0.28 0.12 0.78 0.42 0.14 0.06 S3 0.30 0.10 0.80 0.32 0.18 0.03 The above table shows the Mean and standard Deviation ratio of the files in the 3 different sections of the apical third region(s1 to S3). Table 2: Comparison of the Mean Canal transportation of different files (Apical Third Region) S1 S2 S3 T P significant T P significant T P significant V / s V / s V / s 3.92 <0.001 Sig. 3.66 <0.001 Sig. 4.77 <0.001 Sig. 3.07 <0.001 Sig. 3.34 <0.001 Sig. 3.68 <0.001 Sig. 7.42 <0.001 Sig. 4.83 <0.001 Sig. 6.17 <0.001 Sig. 214

A Comparative evaluation of three different Ni-Ti rotary files using Crown Down technique. An Ex-vivo study... Table 3: Analysis of the Mean Canal transportation of different files (Middle Third Region) Mean SD Mean SD Mean SD S1 0.31 0.21 0.72 0.26 0.10 0.06 S2 0.26 0.15 0.68 0.30 0.12 0.08 S3 0.26 0.12 0.70 0.32 0.14 0.04 Table 4: Comparison of the Mean Canal transportation of different files.(middle Third Region) S1 S2 S3 T P Signifi-cant T P Significant T P Significant V / s 3.93 <0.001 Sig 4.01 <0.001 Sig 4.12 <0.001 Sig V / s 3.08 <0.001 Sig 2.63 <0.001 Sig 3.04 <0.001 Sig V / s 7.44 <0.001 Sig 5.77 <0.001 Sig 5.56 <0.001 Sig Table 5: Analysis of the Mean Canal transportation of different files (Cervical Third Region) Mean SD Mean SD Mean SD S1 0.24 0.12 0.60 0.26 0.08 0.03 S2 0.22 0.14 0.54 0.24 0.10 0.08 S3 0.20 0.10 0.64 0.34 0.12 0.04 Table 6: Comparison of the Mean Canal transportation of different files. (Cervical Third Region). S1 S2 S3 T P Significant T P Significant T P Signifi cant V/s 4.02 <0.001 Sig 3.68 <0.001 Sig 3.97 <0.001 Sig V/s 4.13 <0.001 Sig 2.38 <0.001 Sig 2.37 <0.001 Sig V / s 6.36 <0.001 Sig 5.56 <0.001 Sig 4.86 <0.001 Sig Centricity Ratio: Table 7 : Centricity ratio at middle third of root. files Not Mantained - - - - - Manintained 10 100% 10 100% 10 100% 215

Bhatt A, Rajkumar B, Gupta V Inference:In the middle third, centricity ratio was maintained equally well with no significant difference in the root canals prepared by, & files and least by stainless steel files. Table 8 : Centricity ratio at coronal third of root. files Not Mantained - - - - - Manintained 10 100% 10 100% 10 100% Table 9: Centricity ratio at Apicalthird of root. files Not Mantained 1 10% 2 20% - Manintained 9 90% 8 80% 10 100% Discussion The present study evaluated and compared canal preparation using ProTaper, and files rotary NiTi for canal transportation and centering ability assessed by Computerized tomography. In the majority of previous researches using Ni-Ti systems, a superior ability to maintain root anatomy even in severely curved canals has been described. 16,17,18,19 However, other studies reported no difference between Rotary Ni-Ti systems and Stainless S teel hand Instruments regarding root canal transportation. 20 These divergent outcomes can be attributed to the difference in methodologies, methods of assessment, instrumentation and preparation techniques. Rotary preparation with Ni Ti instruments resulted in high quality canal preparations besides having a potential of speeding up the process of canal preparation. 17 These positive characteristics may also be due to the increased taper of the instruments itself, which would definitely facilitate filling with gutta-percha throughout the full volume of the canal. The manufacturer also stated that the 2% taper on conventional ISO instruments is insufficient for optimum preparation of root canals. 16,18 In this present study, for all the techniques used, no perforations were created during preparation. It can therefore be inferred that the Ni Ti instruments could negotiate and prepare the range of canal shapes at the end-point without any difficulty. Presumably the great flexibility of the Nickel-Titanium alloy and the safe tips of the instruments were largely responsible for the lack of these aberrations and this confirms that even in simulated canals made of relatively soft resin, these Rotary instruments were superior to Stainless Steel hand Files. 21,22 When comparing the shaping ability of different preparation techniques of different root canal instruments, it is of importance to have similar apical preparation diameters. 23 In the present investigation, the final apical diameter was set to ISO size 25 file. All the selected teeth were submitted to CT scan for evaluation. Recently, Computed Tomography evolved into an exciting tool for experimental Endodontology. 24 No destructive sectioning of specimen is required and there is no loss of root material during sectioning, which could affect results. Each cut plane is an exact section ofthe specimen at right angles to the root canal. The CT scan allows easy measurement of canal changes as each image has an accurate scale, decreasing the potential of Radiographic or photographic transfer error. The cost of CT scan is a consideration which currently inhibits the universal utilization of this methodology. Various studies investigated rotary root canal preparations. They showed that Ni-Ti maintained original canal shape better than stainless steel hand files. 25,26,27,28,29,30 In the present study, an evaluation and comparison between instruments produced by using the twisting method (TF) versus instruments produced with the traditional Ni-Ti grinding process (M-two and ProTaper) was performed to evaluate canal transportation and centering ratio. With similar apical preparation diameter, the results showed that Files significantly produced the least transportation and a better centering ratio, followed by the and the ProTaper system. The instruments sequence finished with an instrument 6% taper and determined minor apex transportation; regarding the ProTaper, whose last instrument introduced was 8% taper (therefore less flexible), with a risk of apex transportation. The ProTaper system demonstrated a tendency to straighten curved canals. These results were 216

A Comparative evaluation of three different Ni-Ti rotary files using Crown Down technique. An Ex-vivo study... in accordance with previous studies. 31, 32, 33, 34 The fact that ProTaper system remained less centered and transported more canal preparations might be because of the variable tapers along the cutting surface of these files, in combination with the sharp cutting edges because of their cross-sectional design. Files instruments a centered preparation and maintained the original shape of the curved canal. Because Files are manufactured by twisting Ni-Ti wire, the better shaping results can be explained by the fact that Files are more flexible than Ni-Ti grinded instruments. Schafer and Vlassis concluded from their study on the relationship between taper size and flexibility that Ni-Ti files with tapers greater than 0.04 should not be used for apical enlargement of curved canals. 34 This study revealed that 0.08 tapered Files could be used for apical preparation without creating severe aberrations when using less tapered files before the 0.08 tapered ones. Within the parameters of this study, Files produced significantly less transportation and remained centered around the root canal to a greater degree than did the other techniques; the reasons for this could be because TF has a triangular cross-section that enhances flexibility and generates less friction inside the canal walls due to a lack of peripheral lands. Moreover, it has a variable pitch that minimizes the screw-in effect and allows debris to be effectively channelledout of the canal due to flute widths and flute depths that become accentuated towards the hand piece. Also, a proprietary surface conditioning is there that helps in maintaining the surface hardness of thematerial and sharpness of the edges. Conclusion Within the parameter of this study, according to the results obtained it can be stated that NiTi rotary Files can be used for canal preparation without creating severe aberrations and providing a well centered preparation. 217

Bhatt A, Rajkumar B, Gupta V References 1. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974; 18: 269-96. 2. Hartmann MS, Barletta FB, Camargo Fontanella VR, Vanni JR. Canal transportation after root canal instrumentation: A comparative study with computed tomography. J Endod 2007; 33:962-65. 3. Schafer E. Effects of four instrumentation techniques on curved canals: A comparison study. J Endod 1996; 22:685-89. 4. Schafer E, Tepel J, Hoppe W. Properties of endodontic hand instruments used in rotary motion: Part 2: Instrumentation of curved canals. J Endod 1995; 21:493-7. 5. Glossen CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven and K-Flex endodontic instruments. J Endod 1995; 21:146-51. 6. Gambill JM, Alder M, del Rio CE. Comparison of nickeltitanium and stainless steel hand-file instrumentation using computed tomography. J Endod1996 ; 22:369-75. 7. Nagaraja S, S Murthy B V. CT evaluation of canal Preparation using rotary and hand NiTiinstruments: An in-vitro study. J Conserv Dent 2010; 13:16-22. 8. Thompson SA, Dummer PMH. (a) Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part-1. IntEndodon J 1997;30: 1-7. 9. Thompson SA, Dummer PMH. (b) Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part-2. IntEndodon J 1997; 30: 8-15. 10. Thompson SA, Dummer PMH. (c) Shaping ability of Ni-Ti engine and McXim rotary nickel-titanium instruments in simulated root canals. Part -1. IntEndodon J 1997;30:262-69. 11. Thompson SA, Dummer PMH. (d) Shaping ability of Ni- Ti engine and McXim rotary nickel-titanium instruments in simulated root canals. Part-2. IntEndodon J 1997; 30: 270-78. 12. Guelzow A, StammO, Martus P, Kielbassa A M. Comparative study of six rotary nickel titanium systems and hand instrumentation for root canal preparation. IntEndodon J 2005; 38: 743 752. 13. Al-omari MAO, Dummer PMH, Newccomberge RG. Comparison of six files to prepare simulated root canals. Part-2. IntEndodon J 1992; 25: 67-81. 14. Al-omari MAO, Bryant S, Dummer PMH. Comparison of two Stainless steel files to shape simulated root canals. IntEndodon J 1992; 30:35-45. 15. Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts P. Progressive versus constant tapered shaft design using NiTi rotary instruments. IntEndodon J 2003;36, 288 95. 16. J.M. Gambill, M. Alder and C.E. Del Rio, Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography, J Endod1996, 22: 369 75. 17. C.R. Glosson, R.H. Haller, B. Dove and C.E. del Rio, A comparison of root canal preparations using Ni Ti hand, Ni Ti engine-driven and K-Flex endodontic instruments, J Endod1995;21:146 51. 18. J.A. Short, L.A. Morgan and J.C. Baumgartner, A comparison of canal centering ability of four instrumentation techniques, J Endod1997; 23:503 7. 19. S.J. Jardine and K. Gulabivala, An in vitro comparison of canal preparation using two automated rotary nickel titanium instrumentation techniques, IntEndod J 2000;33: 381 91. 20. M. Hulsmann, G. Gressmann and F. Schafers. A comparative study of root canal preparation using Flex Master and Hero 642 rotary Ni Ti instruments, IntEndod J 2003;36: 358 66. 21. H. Park. A comparison of Greater Taper files, ProFiles, and stainless steel files to shape curved root canals, Oral Surg Oral Med Oral Pathol Oral RadiolEndod 2001;91:715 18. 22. J. Versumer, M. Hulsmann and F. Schafers. A comparative study of root canal preparation using ProFile.04 and Lightspeed rotary Ni Ti instruments, IntEndod J 2002;35: 37 46. 23. DH. Yun and S.K. Kim, A comparison of the shaping abilities of 4 NiTi rotary instruments in simulated root canals, Oral Surg Oral Med Oral Pathol Oral RadiolEndod2003;95:228 33. 24. H.H. Javaheri, G.H. Javaheri. A comparison of three Ni- Ti instruments in apical transportation, J Endod2007;33: 284 86. 25. M.L. Iqbal, S. Firic, J. Tulcan, B. Karabucak, S. Kim. Comparison of apical transportation between ProFile and ProTaperNiTi rotary instruments, IntEndod J 2004; 37: 359 64. 26. E. Schafer, M. Vlassis. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus Race part 1:shaping ability in simulated curved canals, IntEndod J 2004;37: 229 38. 218